cleanled - empire lighting - home · clear-vu lighting’s cleanled ... 3 4559 4061 3676 3369 4438...

4
cleanLED LED LIGHTING FIXTURES FOR CONTROLLED ENVIRONMENTS 1150 Motor Parkway | Central Islip, NY 11722 | 516.941.3737 | [email protected] www.clearvulighting.com 081216 The hermetically sealed swing-lock mounting brackets are adjustable without removing the lens frame, greatly reducing installation time. LED boards (shown in green) are mounted directly to integral heat sink/heat fins maximizing conducted heat dissipation Patent-pending Mono-Gasket System (shown in black) insulates controlled environments from the plenum space and provides water-tight/dust-tight protection for the interior of the lighting fixture One-piece overlapping lens frame fasteners are positioned very close to the perimeter of the lens frame, facilitating consistent ceiling structure contact Clear-Vu Lighting’s cleanLED luminaires are designed to maximize the effectiveness/efficiency of LED technology and protect the integrity of clean room (ISO3-ISO8) and containment area (BSL3 and BSL4) environments. cleanLED is the first lighting fixture series designed and tested to National Sanitation Foundation’s new protocol (P442) “Lighting Fixtures for Controlled Environments” – clean room, containment area and surgical suites. P442 addresses three types of leakage (plenum to room, room to plenum, and plenum/room to lighting fixtures interior), ease of cleanability, corrosion, toxicity and interface with ceiling structure. Other pending listings, ratings, certifications and protocols include: IP66 (ISO60598); Hazardous Locations – Optional Class I, Division 2; Class II, Division 2; NSF2 (Splash Zone); LM79; LM80; DLC Qualified. Optional MIL STD 461F. First-time innovations include: deep-draw stainless steel lens frame with no surface welding; universal installation design (recessed/flange and 2.0 T-Bar); edge-lit LED panel; one-piece mono- gasket system; wire and install without removing lens frame; LED heat sink/heat fin aluminum housing design; factory leakage testing and registration of every lighting fixture – 100%. FEATURES AND BENEFITS: BEST-IN-CLASS LED LIGHT ENGINE Edge-Lit LED light panels produce even facial luminance and glare free uniform lighting distribution DLC qualified 80,000 hour design life – 5 year warranty HIGH-TECH ENCLOSURE Heavy duty, low-profile (2.0”) extruded aluminum housing and die-cast end caps maximize conducted heat dissipation and produce a housing strong enough for walkable ceilings One-piece, deep-draw stainless steel lens frame is free of surface welding. 60º beveled edge produces a progressive surface with the ceiling One-piece Mono-Gasket System seals housing to ceiling structure and lens frame to housing UNMATCHED CONTROLLED ENVIRONMENT PERFORMANCE Independent Lab and factory tested for leakage – IP66 (ISO60598) and National Sanitation Foundation P442. Each fixture factory leakage tested and registered* Independent Lab tested for ease of cleanability, corrosion resistance and toxicity – National Sanitation Foundation P442 and NSF2 Class I, Division 2 and Class II, Division 2 listed to assure safe operation in hazardous locations Optional MIL STD 461F* Hermetically sealed wire-way junction and swing-lock mounting brackets protect the housing interior from plenum space contaminants EASE OF INSTALLATION Lens frame does not need to be removed for wiring or installation Lighting fixture designed for universal installation (recessed/flange or 2.0” T-Bar) Pharmaceutical • Biotech Biosafety • Research Facilities • Hazardous Locations

Upload: phamkhuong

Post on 14-Sep-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: cleanLED - Empire Lighting - Home · Clear-Vu Lighting’s cleanLED ... 3 4559 4061 3676 3369 4438 3984 3627 3339 3838 3532 3281 3702 3443 3224 3577 3358 3170 3065

cleanLED™

LED LIGHTING FIXTURES FOR CONTROLLED ENVIRONMENTS

1150 Motor Parkway | Central Islip, NY 11722 | 516.941.3737 | [email protected] www.clearvulighting.com

081216

The hermetically sealed swing-lock mounting brackets are adjustable without removing

the lens frame, greatly reducing installation time. LED boards (shown in green) are

mounted directly to integral heat sink/heat fins maximizing conducted heat dissipation

Patent-pending Mono-Gasket System™ (shown in black) insulates controlled

environments from the plenum space and provides water-tight/dust-tight protection for

the interior of the lighting fixture

One-piece overlapping lens frame fasteners are positioned very close to the

perimeter of the lens frame, facilitating consistent ceiling structure contact

Clear-Vu Lighting’s cleanLED™ luminaires are designed to maximize the effectiveness/efficiency of LED technology and protect the integrity of clean room (ISO3-ISO8) and containment area (BSL3 and BSL4) environments.

cleanLED is the first lighting fixture series designed and tested to National Sanitation Foundation’s new protocol (P442) “Lighting Fixtures for Controlled Environments” – clean room, containment area and surgical suites. P442 addresses three types of leakage (plenum to room, room to plenum, and plenum/room to lighting fixtures interior), ease of cleanability, corrosion, toxicity and interface with ceiling structure. Other pending listings, ratings, certifications and protocols include: IP66 (ISO60598); Hazardous Locations – Optional Class I, Division 2; Class II, Division 2; NSF2 (Splash Zone); LM79; LM80; DLC Qualified. Optional MIL STD 461F.

First-time innovations include: deep-draw stainless steel lens frame with no surface welding; universal installation design (recessed/flange and 2.0 T-Bar); edge-lit LED panel; one-piece mono-gasket system; wire and install without removing lens frame; LED heat sink/heat fin aluminum housing design; factory leakage testing and registration of every lighting fixture – 100%.

FEATURES AND BENEFITS:

BEST-IN-CLASS LED LIGHT ENGINE• Edge-Lit LED light panels produce even facial

luminance and glare free uniform lighting distribution

• DLC qualified

• 80,000 hour design life – 5 year warranty

HIGH-TECH ENCLOSURE• Heavy duty, low-profile (2.0”) extruded aluminum

housing and die-cast end caps maximize conducted heat dissipation and produce a housing strong enough for walkable ceilings

• One-piece, deep-draw stainless steel lens frame is free of surface welding. 60º beveled edge produces a progressive surface with the ceiling

• One-piece Mono-Gasket System™ seals housing to ceiling structure and lens frame to housing

UNMATCHED CONTROLLED ENVIRONMENT PERFORMANCE• Independent Lab and factory tested for leakage

– IP66 (ISO60598) and National Sanitation Foundation P442. Each fixture factory leakage tested and registered*

• Independent Lab tested for ease of cleanability, corrosion resistance and toxicity – National Sanitation Foundation P442 and NSF2

• Class I, Division 2 and Class II, Division 2 listed to assure safe operation in hazardous locations

• Optional MIL STD 461F*

• Hermetically sealed wire-way junction and swing-lock mounting brackets protect the housing interior from plenum space contaminants

EASE OF INSTALLATION• Lens frame does not need to be removed for

wiring or installation

• Lighting fixture designed for universal installation (recessed/flange or 2.0” T-Bar)

Pharmaceutical • Biotech Biosafety • Research Facilities • Hazardous Locations

Page 2: cleanLED - Empire Lighting - Home · Clear-Vu Lighting’s cleanLED ... 3 4559 4061 3676 3369 4438 3984 3627 3339 3838 3532 3281 3702 3443 3224 3577 3358 3170 3065

1150 Motor Parkway | Central Islip, NY 11722 | 516.941.3737 | [email protected] www.clearvulighting.com

081216

PHOTOMETRICS

ORDERING INFORMATION

cleanLED™

FOR RECESSED FLANGE OR 2.0” T-BAR GRID 1X4

DIMENSIONAL DATA – Housing requires a ceiling cutout of 9.75” x 45.75”

SPECIFICATIONS

Housing: Low-profile (2.0”) extruded aluminum housing with die-cast aluminum end caps. Extrusion profile produces internal heat sink and external heat fins to conduct/dissipate heat away from LED junction point to the housing exterior. Housing will support 1,000 pounds for walkable ceiling applications.

Lens Frame: One-piece, deep-draw fabricated Type 304 or Type 316 stainless steel lens frame free of surface welding. 60 degree beveled edge produces a progressive surface with the ceiling.

Optics: Edge lit LED optics. Light guide panel provides even facial illuminates and eliminates glare. Available in 4,000K, 5,000K and UV filtering amber.

Electrical: 100-277 VAC integral high efficiency driver and power supply (>0.90 power factor). Optional dimming (0-10V) and 1100 Lumens Flash 90-minute battery back-up (regular and Class I, Division 2/ Class II, Division 2).

Installation: Hermetically sealed wire-way junction (with 10’ hazardous location whip [18/5] for Class II applications. Integral J-Box for all other applications – see Dimensional Data. Designed for universal installation – 2.0 T-Bar grid, modular ceiling panel (2”-3”) and stick-built gypsum ceilings. Wiring and installation does not require removal of lens frame.

Pending Listings, Ratings, Certifications and Protocols: IP66 (ISO60598); Hazardous Locations – Class I, Division 2; Class II, Division 2; NSF2 (Splash Zone); National Sanitation Foundation P442; LM79; LM80; DLC Qualified. Optional MIL STD 461F.

PROJECT INFORMATION

Project Name/Location __________________________________________________

Fixture Type __________________________________________________

Fixture Quantity __________________________________________________

Catalog Number __________________________________________________

– ––– – – – –

LENS

CTG= .125” Clear Tempered Glass

CIA= .125” Clear Impact Acrylic

LENS FRAME

LFSS304= 18-gauge Type 304 Stainless Steel

LFSS316= 18-gauge Type 316 Stainless Steel

CLF14

SERIES

CLF14= cleanLED recessed flange or 2.0” T-bar grid 1x4

HAL

HOUSING

HAL= Extruded aluminum with die-cast end caps

UV

VOLTAGE

UV= Universal Voltage (100-277 VAC)

LIGHT ENGINE

S1=55 W/ 5,000 lm

M1=80 W/ 7,500 lm

H1=110 W/ 10,000 lm

VH1=165 W/ 15,000 lm

UH1=220 W/ 20,000 lm

*All lumens initial

COLOR TEMP.

N=4,000K

C=5,000K

A=Amber UV Filtering

NB= No Backup

IBB= Integral Battery Back-up

HBB= Class I, Div 2 Battery Back-up

BACKUP

MS= MIL STD 461F

C1D2= Class I, Div 2

C2D2= Class II, Div 2

OPTIONS

47.965”6.140” 4.710”2.247”

4.162”1.788” 0.510”

11.961” 40.165”

5.650”

4.710”

2.315”

0.470”

1.865”

POLAR GRAPH

RC 80 70 50 30 10 0RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 00 6046 6046 6046 6046 5906 5906 5906 5906 5643 5643 5643 5403 5403 5403 5183 5183 5183 50791 5579 5360 5163 4986 5444 5246 5067 4905 5032 4885 4751 4835 4716 4606 4654 4559 4470 43672 5108 4721 4400 4130 4978 4626 4331 4081 4448 4201 3987 4285 4078 3897 4133 3963 3812 37063 4680 4178 3789 3479 4558 4099 3739 3448 3650 3642 3388 3812 35550 3330 3685 3463 3274 31674 4301 3724 3301 2978 4188 3657 3262 2957 3532 3189 2917 3416 3119 2878 3308 3052 2840 27345 3966 3342 2906 2584 3862 3286 2877 2570 3180 2819 2543 3082 2765 2516 2990 2712 2489 23856 3671 3020 2583 2270 3576 2972 2560 2260 2882 2515 2240 2798 2471 2221 2719 2429 2202 21017 3409 2746 2316 2015 3323 2705 2297 2007 2628 2261 1993 2556 2225 1979 2488 2191 1965 18678 3177 2511 2092 1804 3099 2476 2077 1799 2410 2048 1788 2348 2018 1777 2289 1990 1767 16739 2971 2309 1903 1629 2901 2279 1890 1625 2221 1866 1616 2167 1842 1608 2116 1819 1600 151010 2788 2133 1741 1481 2724 2107 1731 1478 2057 1710 1471 2040 1690 1465 1966 1671 1458 1372Co

effic

ient

s of

Util

izat

ion

Effe

ctiv

e Fl

oor C

avity

Refl

ecta

nce

0.20

Zone Lumens %Fixt0-40 2564 50.5 %

0-60 4286 84.4 %

0-90 5079 100.0 %

90-180 0 0%

ZONAL LUMEN SUMMARY

Catalog No.: CLF14-S1Test Number: 11398264Lumens: 5079

500

1000

1500

2000

Page 3: cleanLED - Empire Lighting - Home · Clear-Vu Lighting’s cleanLED ... 3 4559 4061 3676 3369 4438 3984 3627 3339 3838 3532 3281 3702 3443 3224 3577 3358 3170 3065

1150 Motor Parkway | Central Islip, NY 11722 | 516.941.3737 | [email protected] www.clearvulighting.com

081216

ORDERING INFORMATION

cleanLED™

FOR RECESSED FLANGE OR 2.0” T-BAR GRID 2X2

DIMENSIONAL DATA – Housing requires a ceiling cutout of 21.75” x 21.75”

SPECIFICATIONS

Housing: Low-profile (2.0”) extruded aluminum housing with die-cast aluminum end caps. Extrusion profile produces internal heat sink and external heat fins to conduct/dissipate heat away from LED junction point to the housing exterior. Housing will support 1,000 pounds for walkable ceiling applications.

Lens Frame: One-piece, deep-draw fabricated Type 304 or Type 316 stainless steel lens frame free of surface welding. 60 degree beveled edge produces a progressive surface with the ceiling.

Optics: Edge lit LED optics. Light guide panel provides even facial illuminates and eliminates glare. Available in 4,000K, 5,000K and UV filtering amber.

Electrical: 100-277 VAC integral high efficiency driver and power supply (>0.90 power factor). Optional dimming (0-10V) and 90 minute battery back-up (regular and Class I, Division 2/ Class II, Division 2).

Installation: Hermetically sealed wire-way junction (with 10’ hazardous location whip [18/5] for Class II applications. Integral J-Box for all other applications – see Dimensional Data. Designed for universal installation – 2.0 T-Bar grid, modular ceiling panel (2”-3”) and stick-built gypsum ceilings. Wiring and installation does not require removal of lens frame.

Pending Listings, Ratings, Certifications and Protocols: IP66 (ISO60598); Hazardous Locations – Class I, Division 2; Class II, Division 2; NSF2 (Splash Zone); National Sanitation Foundation P442; LM79; LM80; DLC Qualified. Optional MIL STD 461F.

PROJECT INFORMATION

Project Name/Location __________________________________________________

Fixture Type __________________________________________________

Fixture Quantity __________________________________________________

Catalog Number __________________________________________________

23.965”17.650”

4.065”

6.349”

2.779”

4.710”

4.710”3.155”2.345”

2.010”

1.670”1.930”

23.965”

18.385”

– ––– – – – –

LENS

CTG= .125” Clear Tempered Glass

CIA= .125” Clear Impact Acrylic

LENS FRAME

LFSS304= 18-gauge Type 304 Stainless Steel

LFSS316= 18-gauge Type 316 Stainless Steel

CLF22

SERIES

CLF22= cleanLED recessed flange or 2.0” T-bar grid 2x2

HAL

HOUSING

HAL= Extruded aluminum with die-cast end caps

UV

VOLTAGE

UV= Universal Voltage (100-277 VAC)

LIGHT ENGINE

S1=55 W/ 5,000 lm

M1=80 W/ 7,500 lm

H1=110 W/ 10,000 lm

*All lumens initial

COLOR TEMP.

N=4,000K

C=5,000K

A=Amber UV Filtering

NB= No Backup

IBB= Integral Battery Back-up

HBB= Class I, Div 2 Battery Back-up

BACKUP

MS= MIL STD 461F

C1D2= Class I, Div 2

C2D2= Class II, Div 2

OPTIONS

PHOTOMETRICS RC 80 70 50 30 10 0RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 00 5913 5913 5913 5913 5775 5775 5775 5775 5518 5581 5518 5284 5284 5284 5068 5068 5068 49671 5448 5230 5034 4858 5315 5118 4940 4779 4908 4762 4629 4716 4597 4488 4538 4444 4355 42542 4981 4597 4279 4011 4853 4504 4212 3964 4330 4084 3872 4169 3964 3784 4020 3852 3701 35973 4559 4061 3676 3369 4438 3984 3627 3339 3838 3532 3281 3702 3443 3224 3577 3358 3170 30654 4185 3614 3196 2877 4074 3549 3159 2857 3426 3087 2818 3312 3018 2780 3206 2953 2744 26395 3857 3241 2810 2492 3755 3186 2781 2478 3082 2725 2452 2985 2671 2426 2630 2620 2400 22976 3567 2925 2495 2186 3474 2879 2472 2176 2790 2427 2157 2708 2385 2138 2799 2344 2120 20207 3311 2658 2234 1937 3227 2618 2216 1930 2542 2180 1916 2471 2145 1902 2405 2112 1889 17938 3085 2429 2016 1733 3008 2395 2002 1728 2330 1972 1717 2269 1944 1707 2211 1917 1697 16049 2884 2062 1833 1563 2815 2203 1820 1559 2146 1796 1551 2093 1773 1543 2043 1750 1535 1446

10 2706 2186 1676 1420 2643 2036 1666 1417 1987 1646 1410 1941 1626 1404 1897 1607 1398 1313Coef

ficie

nts

of U

tiliz

atio

n Ef

fect

ive

Floo

r Cav

ity R

eflec

tanc

e 0.

20

Zone Lumens %Fixt0-40 2451 49.3 %

0-60 4147 83.5 %

0-90 4966 100.0 %

90-180 0 0%

ZONAL LUMEN SUMMARY

POLAR GRAPH

Catalog No.: CLF22-S1-C-UVTest Number: 1219170Lumens: 4967

Page 4: cleanLED - Empire Lighting - Home · Clear-Vu Lighting’s cleanLED ... 3 4559 4061 3676 3369 4438 3984 3627 3339 3838 3532 3281 3702 3443 3224 3577 3358 3170 3065

1150 Motor Parkway | Central Islip, NY 11722 | 516.941.3737 | [email protected] www.clearvulighting.com

081216

ORDERING INFORMATION

cleanLED™

FOR RECESSED FLANGE OR 2.0” T-BAR GRID 2X4

DIMENSIONAL DATA – Housing requires a ceiling cutout of 21.75” x 45.75”

SPECIFICATIONS

Housing: Low-profile (2.0”) extruded aluminum housing with die-cast aluminum end caps. Extrusion profile produces internal heat sink and external heat fins to conduct/dissipate heat away from LED junction point to the housing exterior. Housing will support 1,000 pounds for walkable ceiling applications.

Lens Frame: One-piece, deep-draw fabricated Type 304 or Type 316 stainless steel lens frame free of surface welding. 60 degree beveled edge produces a progressive surface with the ceiling.

Optics: Edge lit LED optics. Light guide panel provides even facial illuminates and eliminates glare. Available in 4,000K, 5,000K and UV filtering amber.

Electrical: 100-277 VAC integral high efficiency driver and power supply (>0.90 power factor). Optional dimming (0-10V) and 90 minute battery back-up (regular and Class I, Division 2/ Class II, Division 2).

Installation: Hermetically sealed wire-way junction (with 10’ hazardous location whip [18/5] for Class II applications. Integral J-Box for all other applications – see Dimensional Data. Designed for universal installation – 2.0 T-Bar grid, modular ceiling panel (2”-3”) and stick-built gypsum ceilings. Wiring and installation does not require removal of lens frame.

Pending Listings, Ratings, Certifications and Protocols: IP66 (ISO60598); Hazardous Locations – Class I, Division 2; Class II, Division 2; NSF2 (Splash Zone); National Sanitation Foundation P442; LM79; LM80; DLC Qualified. Optional MIL STD 461F.

PROJECT INFORMATION

Project Name/Location __________________________________________________

Fixture Type __________________________________________________

Fixture Quantity __________________________________________________

Catalog Number __________________________________________________

47.965” A

A

17.650”

2.000”

2.885”

23.965”40.165”

4.037”

6.1404.7104.719

6.349

4.719

6.349

6.1404.710

– ––– – – – –

LENS

CTG= .125” Clear Tempered Glass

CIA= .125” Clear Impact Acrylic

LENS FRAME

LFSS304= 18-gauge Type 304 Stainless Steel

LFSS316= 18-gauge Type 316 Stainless Steel

CLF24

SERIES

CLF24= cleanLED recessed flange or 2.0” T-bar grid 2x4

HAL

HOUSING

HAL= Extruded aluminum with die-cast end caps

UV

VOLTAGE

UV= Universal Voltage (100-277 VAC)

LIGHT ENGINE

S1=55 W/ 5,000 lm

M1=80 W/ 7,500 lm

H1=110 W/ 10,000 lm

VH1=165 W/ 15,000 lm

UH1=220 W/ 20,000 lm

*All lumens initial

COLOR TEMP.

N=4,000K

C=5,000K

A=Amber UV Filtering

NB= No Backup

IBB= Integral Battery Back-up

HBB= Class I, Div 2 Battery Back-up

BACKUP

MS= MIL STD 461F

C1D2= Class I, Div 2

C2D2= Class II, Div 2

OPTIONS

PHOTOMETRICS

Zone Lumens %Fixt0-40 2641 49.4 %

0-60 4470 83.6 %

0-90 5344 100.0 %90-180 0 0%

ZONAL LUMEN SUMMARY

RC 80 70 50 30 10 0RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 00 6363 6363 6363 6363 6215 6215 6215 6215 5938 5938 5938 5686 5686 5686 5454 5454 5454 53451 5863 5629 5419 5230 5720 5508 5318 5145 5283 5126 4983 5076 4949 4831 4885 4783 4688 45792 5362 4949 4607 4319 5224 4849 4535 4268 4661 4397 4169 4488 4268 4075 4329 4147 3985 38743 4907 4373 3959 3629 4778 4289 3906 3597 4132 3804 3533 3987 3707 3473 3852 3616 3414 33014 4506 3892 3442 3099 4386 3822 3402 3078 3690 3325 3036 3567 3251 2995 3452 3180 2955 28435 4152 3489 3026 2684 4042 3430 2995 2670 3318 2935 2641 3214 2877 2613 3117 2822 2585 24756 3840 3150 2686 2354 3740 3100 2662 2344 3004 2614 2323 2916 2568 2303 2832 2524 2283 21767 3564 2861 2406 2086 3473 2818 2386 2079 2737 2347 2064 2661 2310 2049 2589 2274 2034 19318 3321 2615 2171 1866 3238 2578 2155 1860 2508 2123 1849 2442 2093 1838 2380 2064 1827 17279 3104 2403 1973 1683 3030 2371 1960 1678 2310 1934 1670 2253 1908 1661 2200 1884 1653 1557

10 2912 2219 1084 1528 2844 2191 1793 1525 2139 1771 1518 2089 1750 1511 2042 1730 1505 1413Coef

ficie

nts

of U

tiliz

atio

n Ef

fect

ive

Floo

r Cav

ity R

eflec

tanc

e 0.

20

Catalog No.: CLF24-S1-C-UVTest Number: 1219173Lumens: 5345

POLAR GRAPH