CODE:MK3065/MK3030CODE:MK3065/MK3030
This manual refers to the model MALCRW010ZA~MALCRW060ZA/SMALCRW025ZA1~MALCRW060ZA1/SMALCRW025ZB~MALCRW060ZB/S
METRAN
-
Congratulations on your wise decision to make an heat pump part of your
home. has maintained the worldwide lead in the manufacture of swimming
pool & spa heat pumps. Your new heat pump is not only a great investment, but also
the most cost effective method available for
heating pools and spas. For example, your
heat pump is up to 400% more efficient than
gas, and, when compared to electric resist-
ance heat, your heat pump is nearly 600%
more effective. You can rest assured your
new heat pump is of the highest quality and
efficiency, and is designed and built to pro-
vide years of trouble-free operation.
Moreover, should you ever require help in
using or maintaining your heat pump, you
will find customer and technical support staff to be the largest, most qualif-
ied, and of utmost importance themost easily accessed customer service team in
the pool & spa heat pump industry.
You can rest assuredknowing your new heatpump is of the highestquality and efficiency,
and is designed andbuilt to provide years
of trouble-freeoperation.
Welcometo
Dear Owner:
METRAN
METRAN
METRAN
METRAN
-
Contents
SWIMMING POOL HEAT PUMP
Important Features of Your New Heat Pump--------------
I Specification ------------------------------------------------- --------------------------------------------------
2.Performance ------------------------------------------- ----------------------
3.The dimension for Swimming Pool Heat Pump Unit-Monobloc------
II Installation--------------------------------------------------- -----------------------
---------------------------
3. Electric wiring --------------------------------------------------------------
----------------------------------------------
1.Functional illustration of the remote controller-------------------------
2. Uses of the remote controller---------------------------------------------
3. Operation Data Setting---------------------------------------------------
IV Maintenance ---------------------------------------------- Ordinary malfunctions and solution----------------------------------------
Attachment 1 --------------------------------------------------- 1. Connection of PCB --------------------------------------------------------
2. Wiring diagram-------------------------------------------------------------
Attachment 2 --------------------------------------------------- How to obtain Service--------------------------------------------------------
1. Model Nomenclature------
1. Positioning Your Swimming Pool Heat Pump----
2. Connecting Your Swimming Pool Pipe Work
III Use -----------------------------------------------------------
4. Selection of Electrical Wire
1
22
3
3
66
7
8
9
1010
10
13
1314
1515
15
1818
-
1
Digitally-based microprocessor controls water temperature to within 1 of set po-int. Controller also permits user to predefine different pool and spa water temperatures, and to prevent tampering by locking out controls via a .
Celcius
control key
50% fewer moving parts than standard piston-type compressors. This equates to much improved reliability and improved efficiency. Scroll compressors are also much quieter inoperation than their piston-type counterparts. And, while all heat pumps are known for their low operating noise levels.
The cabinet of the ZA1 model , being made from resilient, UV-Protected ABS material, has superior fade resistance and can never rust or corrode. You can expect the cabinet to retain a like-new appearance with only an occasional wash down and if so desired a quick waxing.
Corrosion-Proof Cabinet
Digital Controller
Scroll Compressor
Hot Gas Defrost*
Hot gas defrost heat pumps are uniquely equipped for an active defrost cycle. Active def-rost involves directing hot refrigerant vapor to the heat collector, melting accumulated iceaway in a matter of a few minutes... then right back to heating. Standard defrost heat pu-mps may remain off in defrost for extended periods during very cold weather. Becau-se of their ability to continue to operate-even during freezing weather-hot gas defrost models extend the swimming season longer than any standard-defrost heat pump.
PLEASE READ FURTHER TO BECOME FAMILIAR WITH ALL THE FEATURES, THE SAFEOPERATION, AND THE CARE OF YOUR NEW HEAT PUMP.
SWIMMING POOL HEAT PUMP
The heart of your heat pump is the patented heat exchanger. One of the primary causes of premature heat pump demise is the failure of the heat exchanger. Ordinary heat exchangers are made from a cupronickel alloy . This cupron-ickel material is susceptible to attack from the sanitizers used in pools and spas and from other related water chemistry conditions. Once the heat exchanger fails, the heat pump isruined.
The heat exchanger tube is made from titanium, and is virtually impervious to water chemistry damage,
and the shell is made by PVC
And The PVC is can't bear too high pressure and temperature, and exit the risk of
burst and leak. and the shell is made a patent secret ingredients,
it can stand more than 21kg water pressure and high temperature.
Heat Exchanger
Important Features of YourNew Heat Pump
Puts you in full control, year round... Warms your pool or spa with the reliability andefficiency of our other heat pumps, but, with the flip of a switch, can also cool your poolor spa to refreshing temperatures during hot summer months. For cooler climates,Heat & Cool heat pumps offer unique advantages over passive defrost models. Pleaseread more below...
Heat & Cool Capability*
METRAN
METRAN
-
Notice1.1 In order to use this product better and safer, please read this instruction carefully before install
and operate it. Please pay attention to all the notice in operation and maintenance. Save all
manuals and documentation for future reference.
1.2 Swimming pool heat pump is a special appliance. Improper installation will cause damage and
danger. It should be installed and maintained by the professionals. Please contact our authori-
zed local service point for installation and maintenance. Please read and follow this instruction
carefully before and during installation.
Remarks:
We will not bear the responsibility for any personal injury or unit damage caused by
non-Compliance of the regulations and instruction in this manual.
1.3 Please check whether the distribution power capacity, switch and socket are compliance with
the requirements of our unit power. Details please refer to the rating label or parameter table
in this manual.
1.4 The power should be equipped with leakage protection separately. Power cable should be
chosen in accordance with the operation requirements of the unit.
1.5 The unit must be grounded safely. Do not use the unit if grounded unsafely. Do not connect
the ground line to the neutral and or tap water pipe.
1.6 The wire must be joined in compliance with the requirements of the wiring chart. Do not
alternate and or repair the unit personally.
1.7 Do not install the unit closed to inflammable, explosive and naked light spot.
1.8 To ensure the unit operate properly, please equipped with a filter in the water input when
installation.
1.9 Please contact us or our authorized service site if the unit failures. The unit can t be used
again without technicians checking.
1.10 The unit parameter has been set before leave of the factory. The parameter Can t be
adjusted by the unprofessional.
SWIMMING POOL HEAT PUMP
I Specification
1. Model Nomenclature
MA LCR W - - Z A / P S 1 ( B D )
Source medium
MA: Air source
MW: Ground source
Function of the unit
LCR: Swimming pool
Energy exchange medium
A: Refrigerant
W: Water
Z: Integrated type
W: Split type(indoor unit ) P: With built in pump,
(without built in pump omitted)
S: 3phase(single phase omitted)
A: Horizontal fan direction
B: Upward fan direction
The figure represents the horse power of unit
eg:010 means 1 horse power
Special function:
B: DC inverter(ellipsis when without this function)
E: EVI technology
Auxiliary electric heater
D: with electric heater(ellipsis when without this function)
Specail requirement
1: ABS case swimming pool heat pump
2: easy operate swimming pool heat pump
(ellipsis when uint is usual type)
-
Note:Heating: Ambient temp.(DB/WB):15 /12 ,Water temp. (In/Out):26 /28 ;
Code
Input power heating
Running current heating
Power supply
Grade of waterproof
Quantity of compressor
Compressor
Quantity of fan
Input power of Fan
Fan rotate speed
Noise
Water connection
Water flow volume
Water pressure drop
Refrigerant gas type
Rated heating capacity
Dimension of outdoor
Weight(Net /Gross)
Package size of outdoor
W
BTU/h
W
A
V/PH/Hz
W
RPM
dB(A)
inch3m /h
kpa
L/W/H(mm)
L/W/H(mm)
L/W/H(mm)
L/W/H(mm)
kg
kg
220V/1PH/50Hz
Rotary
R410a
13500
46100
2500
11.4
IPX4
1
1
90
820
50
1-1/2
5-8
15
1115/470/700
1205/525/725
1000/460/650
1085/495/685
91/97
66/70
15500
52900
2850
13.0
IPX4
1
1
50
820
50
1-1/2
5-8
15
1115/470/700
1205/525/725
1100/470/900
1185/505/935
91/97
75/83
19500
66600
3550
16.1
IPX4
1
1
90
810
53
1-1/2
5-8
15
1115/470/945
1205/525/975
1100/470/900
1185/505/935
105/111
78/86
21500
73200
4000
18.2
IPX4
1
1
90
810
53
1-1/2
5-8
16
1115/470/945
1205/525/975
1100/470/900
1185/505/935
108/116
103/111
12500
42600
2350
10.7
IPX4
1
1
50
820
50
1-1/2
4-7
15
1115/470/700
1205/525/725
1000/460/650
1085/495/685
87/93
65/69
Scroll
*Weight(Net /Gross)
*Dimension of outdoor
*Package size of outdoor
025ZA 027ZA 030ZA 035ZA 040ZA 045ZA
*025ZA1 *027ZA1 *030ZA1 *035ZA1 *040ZA1MALCRW
*045ZA1
24500
83500
4700
21.4
IPX4
1
1
90
810
53
1-1/2
5-8
16
1115/470/945
1205/525/975
1100/470/900
1185/505/935
111/119
106/114
SWIMMING POOL HEAT PUMP
2.1 Side fan swimming pool heat pump unit parameters
Code
Input power heating
Running current heating
Power supply
Grade of waterproof
Quantity of compressor
Compressor
Quantity of fan
Input power of Fan
Fan rotate speed
Noise
Water connection
Water flow volume
Water pressure drop
Refrigerant gas type
Rated heating capacity
Dimension of outdoor
Weight (Net/Gross)
Package size of outdoor
W
BTU/h
W
A
V/PH/Hz
W
RPM
dB(A)
inch3m /h
kpa
L/W/H(mm)
L/W/H(mm)
kg
5000
17100
900
4.1
IPX4
1
1
25
870
48
1-1/2"
2-4
10
930/350/550
1350/395/585
35/38
5500
18800
1000
4.5
IPX4
1
1
25
870
48
1-1/2"
2-4
10
930/350/550
1350/395/585
37/40
7500
25600
1400
6.4
IPX4
1
1
25
870
48
1-1/2"
2-4
12
930/350/550
1035/395/585
53/56
9000
30800
1700
7.7
IPX4
1
1
25
870
48
1-1/2"
3-5
12
930/350/550
1035/395/585
54/57
10500
35900
1900
8.6
IPX4
1
1
40
840
50
1-1/2"
3-5
12
63/67
1005/360/620
1095/405/650
11000
37600
2050
9.3
1
1
50
820
50
1-1/2
4-7
15
1115/470/700
1205/525/725
85/91
IPX4
220V/1PH/50Hz
Rotary
R410a
MALCRW 008ZA 010ZA 015ZA 018ZA 020ZA 023ZA
2.Performance data
3
-
3
Side fan swimming pool heat pump unit parameters
15500
52900
2750
4.8
IPX4
1
Rotary
1
50
820
50
1-1/2
5-8
15
1115/470/700
1205/525/725
105/111
19500
66700
3650
6.4
IPX4
1
1
90
810
53
1-1/2
5-8
15
1115/470/945
1205/525/975
1100/470/900
1185/505/935
106/114
95/103
21000
71700
3750
6.6
IPX4
1
1
90
810
53
1-1/2
5-8
16
1115/470/945
1205/525/975
1100/470/900
1185/505935
108/116
103/111
25000
85300
4750
8.3
IPX4
1
Scroll
1
90
810
53
1-1/2
5-8
16
1115/470/945
1205/525/975
1100/470/900
1185/505/935
111/119
110/118
27000
92200
4950
8.7
IPX4
1
2
90
810
53
1-1/2
6-12
16
1115/470/1250
1205/525/1280
1100/470/1250
1185/505/1280
113/123
115/126
31500
107500
5950
10.4
IPX4
1
2
90
810
53
1-1/2
6-12
16
1115/470/1250
1205/525/1280
1100/470/1250
1185/505/1280
115/125
117/128
Code
Input power heating
Running current heating
Power supply
Grade of waterproof
Quantity of compressor
Compressor
Quantity of fan
Input power of Fan
Fan rotate speed
Noise
Water connection
Water flow volume
Water pressure drop
Refrigerant gas type
Rated heating capacity
Dimension of outdoor
Weight(Net /Gross)
Package size of outdoor
W
BTU/h
W
A
V/PH/Hz
W
RPM
dB(A)
inch3m /h
kpa
L/W/H(mm)
L/W/H(mm)
L/W/H(mm)
L/W/H(mm)
kg
kg
380V/3PH/50Hz
R410a
*Weight(Net /Gross)
*Dimension of outdoor
*Package size of outdoor
030ZA/S 035ZA/S 040ZA/S 045ZA/S 050ZA/S 060ZA/S
*035ZA1/S *040ZA1/S *045ZA1/S *050ZA1/S *060ZA1/SMALCRW
Code
Input power heating
Running current heating
Power supply
Grade of waterproof
Quantity of compressor
Compressor
Quantity of fan
Input power of Fan
Fan rotate speed
Noise
Water connection
Water flow volume
Water pressure drop
Refrigerant gas type
Rated heating capacity
Dimension of outdoor
Net weight
Gross weight
Package size of outdoor
MALCRW
W
BTU/h
W
A
V/PH/Hz
W
RPM
dB(A)
inch3m /h
kpa
L/W/H(mm)
L/W/H(mm)
kg
kg
220V/1PH/50Hz
R410a
10500
35900
1900
8.6
IPX4
1
Rotary
1
150
870
50
1-1/2
3-5
12
660/660/860
750/700/960
70
75
11000
37600
2050
9.3
IPX4
1
Rotary
1
150
870
50
1-1/2
4-7
15
660/660/860
750/700/960
73
78
12500
42600
2350
10.7
IPX4
1
Rotary
1
150
870
50
1-1/2
4-7
15
660/660/860
750/700/960
75
80
13500
46100
2500
11.4
IPX4
1
Rotary
1
150
870
50
1-1/2
4-7
15
660/660/860
750/700/960
78
83
15500
52900
2850
13.0
IPX4
1
Rotary
1
150
870
50
1-1/2
5-8
15
660/660/860
750/700/960
80
88
19500
66600
3550
16.1
IPX4
1
Rotary
1
150
870
53
1-1/2
5-8
15
660/660/860
750/700/960
91
98
2.2 Top fan swimming pool heat pump unit parameters
020ZB 023ZB 025ZB 027ZB 030ZB 035ZB
SWIMMING POOL HEAT PUMP
4
Note:Heating: Ambient temp.(DB/WB):15 /12 ,Water temp. (In/Out):26 /28 ;
Note:Heating: Ambient temp.(DB/WB):15 /12 ,Water temp. (In/Out):26 /28 ;
-
3.The dimension for Swimming Pool Heat Pump Unit-Monobloc
B
A D
C
Units: mm
Size
MALCRW
A
B
C
D
330
680
930
550
340
645
1005
620
470
750
1115
700
470
750
1115
945
B
A D
C
Units: mm
Size
MALCRW
A
B
C
D
370
650
950
600
008ZA 015ZA010ZA 018ZA
020ZA023ZA 030ZA025ZA 025ZA/S027ZA 030ZA/S
035ZA 035ZA/S040ZA 040ZA/S045ZA 045ZA/S
430
600
1020
650
440
700
1100
900
008ZA1010ZA1015ZA1
018ZA1 025ZA1020ZA1 027ZA1023ZA1
030ZA1 030ZA1/S035ZA1 035ZA1/S040ZA1 040ZA1/S045ZA1 045ZA1/S
SWIMMING POOL HEAT PUMP
B
A
D
C
Size
MALCRW
A
B
C
D
440
770
1115
1250
Units: mm
050ZA/S060ZA/S
050ZA1/S060ZA1/S
440
770
1100
1250
5
Code
Input power heating
Running current heating
Power supply
Grade of waterproof
Quantity of compressor
Compressor
Quantity of fan
Input power of Fan
Fan rotate speed
Noise
Water connection
Water flow volume
Water pressure drop
Refrigerant gas type
Rated heating capacity
Dimension of outdoor
Net weight
Gross weight
Package size of outdoor
MALCRW
W
BTU/h
W
A
V/PH/Hz
W
RPM
dB(A)
inch3m /h
kpa
L/W/H(mm)
L/W/H(mm)
kg
kg
380V/3PH/50Hz
R410a
21500
73200
4000
18.2
220V/1PH/50Hz
IPX4
1
Scroll
1
150
870
53
1-1/2
5-8
16
660/660/860
750/700/960
98
120
19500
66700
3650
6.4
IPX4
1
Scroll
1
150
870
53
1-1/2
5-8
15
660/660/860
750/700/960
91
98
21000
71700
3750
6.6
IPX4
1
Scroll
1
150
870
53
1-1/2
5-8
16
660/660/860
750/700/960
98
120
25000
85300
4750
8.3
IPX4
1
Scroll
1
150
870
53
1-1/2
5-8
16
660/660/960
750/700/1060
100
122
27000
92200
4950
8.7
IPX4
1
Scroll
1
150
870
53
1-1/2
6-12
16
660/660/960
750/700/1060
111
123
31500
107500
5950
10.4
IPX4
1
Scroll
1
150
870
53
1-1/2
6-12
16
660/660/960
750/700/1060
113
125
040ZB 035ZB/S 040ZB/S 045ZB/S 050ZB/S 060ZB/S
Top fan swimming pool heat pump unit parameters
Note:Heating: Ambient temp.(DB/WB):15 /12 ,Water temp. (In/Out):26 /28 ;
-
C
Size
MALCRW
A
B
C
A
B 300
685
860
300
685
960
Units: mm
020ZB 023ZB 025ZB 027ZB 030ZB 035ZB040ZB
045ZB/S050ZB/S060ZB/S
035ZB/S040ZB/S
300
685
860
SWIMMING POOL HEAT PUMP
1. Positioning Your Swimming Pool Heat Pump1.1 For correct operation air must be free to circulate around the heat pump. Do not place the unit in a shed, greenhouse or similar. This unit is designed to be placed outdoors only.1.2 Refer to the drawing below for required clearance.1.3 You should position the heat pump so that the control panel does not face directly towards the sun.1.4 The heat pump must be upright.1.5 The distance between the heat pump and the pool / plant room should be as short as practically possible to reduce pressure and heat loss in the pipe work.1.6 Insulating the pipe work will assist with the prevention of heat losses.1.7 An isolator switch should be installed (by a qualified electrician) near the heat pump.1.8 The electrical supply to the heat pump must be protected by a 30mA RCD.1.9 The air inlets and outlets must not be obstructed or blocked.1.10 Even though the heat pump is low noise, it must be positioned so as to be considerate to neighbours.1.11 Your heat pump must be placed on a solid base.1.12 Condensation will drip from underneath the heat pump, your base must be able to tolerate this.
II Installation
1000mm Above
1000mm Above
1000mm Above
1000mm Above
Top 2000mm AboveTop 1000mm Above
1000mm Above
Inlet Inlet
Inlet Inlet
Inlet
Outlet
The position of installing unit
6
-
2. Connecting Your Swimming Pool Pipe Work2.1 The pool water is fed through the heat pump by a swimming pool pump.2.2 The heat pump must be installed after (down stream) the swimming pool filter so clean, filtered water passes through it.2.3 Double union ball valves must be fitted just before the heat pump inlet and just after the outlet to aid servicing and winterising.2.4 Each heat pump has a maximum water flow rate. If the flow via the pool pump is higher than this then a by-pass should be installed. Consult your supplying dealer.2.5 Each heat pump also has a minimum flow rate, below this the heat pump will not operate. Consult your supplying dealer.2.6 Pipe work of less than 1-1/2 diameter should not be used.2.7 Fit a union nut onto each pipe.2.8 Push the gasket over the pipe until the gasket is about 5 -10mm from the edge of the pipe. You may need to lubricate the gasket.2.9 Insert the pipe into the heat pump and tighten the union nut.2.10 The union must only be hand tightened.2.11 If the swimming pool is equipped with a chlorinator, brominator, or possibly chemical control with acid and chlorine pumps, these must be in the return pipe work after the heat pump and a non-return valve used. Any dosing system must be the final equipment before the water returns to the swimming pool. Damage caused to the heat pump by chemical dosing units is not covered by warranty.2.12 Any heat exchanger or electric heater fitted as auxiliary heating must be installed after (down stream from) the heat pump so as to avoid pre-heating the pool water before it enters the heat pump.
SWIMMING POOL HEAT PUMP
SWIMMING POOLSWIMMING POOL
Check-valve
Filter
Water pump
Chlorinator
Check-valve
Installation Drawing Of Side Fan Type
7
-
3.1 Unit supply cable must be used copper. Power supply voltage in line with the rated voltage and the rated current.3.2 The unit, power supply circuit must have a grounding wire, and the power supply ground wire must with the external grounding wire, and an external grounding wire to be effective.3.3 W must be installed by professional technicians carried out in accordance with circuit.3.4 S up a good leakage protection devices
3.5 Power line and signal line layout should be neat, rational, strong and weak lines separating cable and Can not interfere with each other, without contact with the connecting pipe and valve.3.6 he construction of all wiring is completed, carefully check the correct order to connect the power.3.7 Unit electric wire connection: connect to the appropriate terminals according to wiring diagram, and fix it by the pressure line of board in the electrical box. 3.8 All the wiring construction is completed, can be plugged in only after careful examination correctly. 3.9 Unit control board fuse parameters: 5A.
should be
connect toiring installation
etting
After t
and in accordance with the relevant national technical standards.
3. Electric wiring
SWIMMING POOL HEAT PUMP
Chlorinator
SWIMMING POOLSWIMMING POOL
Check-valve
Filter
Water pump
Chlorinator
Check-valve
Installation Drawing Of Top Fan Type
8
-
4. Selection of Electrical Wire
UNITPower supply
PCB Compressor
4.1 Voltage drop may occur due to the large current draw during compressor starting, and may be result in the compressor is difficult to stat. So we recommend selecting the wire specification from the table below.
4.2 Specification Table of Electrical Wire
Power supply installation condition: The touching space of breaker should be more than 3mm.must use copper wire only.
within 5m
2.0
3.5
5.5
8.0
Within 10m
2.0
3.5
5.5
8.0
14.0
Within 15m
2.0
3.5
5.5
8.0
14.0
22.0
Within 20m
3.5
5.5
8.0
14.0
22.0
30.0
Within 30m
5.5
8.0
14.0
22.0
30.0
38.0
50.0
Within 50m
8.0
14.0
22.0
30.0
38.0
50.0
60.0
80.0
Within 1m
2.0
3.5
5.5
8.0
14.0
Starting current (A)
Below 20
Below 30
Below 40
Below 50
Below 60
Below 70
Below 80
Below 90
Below 100
Below 110
Below 120
Below 140
Below 160
Below 180
Below 200
Below 220
Below 240
Mark (Heat resistance temperature above 60 )
The wiring specifications (mm2)
Mark (Heat resistance temperature above 120 )
4.3 Caution of GroundingThe internal motor protector does not protect the compressor against all possible conditions.Please be sure that the system utilizes the ground connection when installed in the field.4.4 Warning: To avoid fire, electric shock and other accidents, keep in mind about these tips: 4.4a Only use power supply voltage indicated on the label, if you do not know the family of voltage, contact the dealer or local power company. 4.4b When you use the unit by the maximum current please view the specifications, so make sure your home's power supply (current, voltage and cable) to meet the machine's normal load requirements. 4.4c To protect the power lines. Power lines should be fixed, so that people will not be trip over or the lines damaged by other things. Paying particular attention to plugs, which should be easily plug into the socket, careful the plug position. 4.4d Do not overload wall plugs or extension the cable. Line overload can cause fire or electric shock. 4.5e To ensure your safety, you must plug the power lines into the socket with a grounded three-phase, and check to ensure your socket is accurate and reliable grounding.
SWIMMING POOL HEAT PUMP
9
-
Standby mode
Ambient temp.
12
Initialization mode
1) Power-on,Afer 10 seconds of full screen display of the remote controller, the main unit enters the standby mode: the remote controller showing ambient temp and running mode.
Auto mode
Water outlet temp.
Cooling mode Heating mode
Water inlet temp.
12
Button control area
The display area ofoperation mode
Running status and parameter setting display area
The electrical base box for the remote controller is of standard dimension(86 * 86,fixed hole distance being 60mm).Before the interior decoration, the box and three-core cable(3 0.5mm2)can be embedded in the wall to make the overall decoration more beautiful. The user interface and functions of use are shown in the figure below
III Use1.Functional illustration of the remote controller
2. Uses of the remote controller
SWIMMING POOL HEAT PUMP
10
2) MODE button for mode selection. Press this button to choose auto cooling
or water heating mode.
-
SWIMMING POOL HEAT PUMP
11
3)power on/off.Press this button to power on the remote controller displays the water inlet temp. ,
water outlet temp. ,clock and operation mode; press button again to enter the standby mode.
6 Timed ON/OFF setting. Press botton and the bit hour, bit minute and timing ON symbol flicker.
Press button,and the bit hour flickers. Press buttons to adjust the setting of the hour.
Press button again,and the bit minute flickers. Press buttons to adjust the setting of minute;
Press button again and the bit hour, bit minute and timing OFFsymbol will flicker. Press button,
and the bit hour flickers. Press buttons to adjust the setting of hour. Press button again,
and the bit minute flickers. Press buttons to adjust the setting of minute. Press button
again to complete and exit the timed ON/OFF setting mode.
Cancel timing setting operation. Press button and press button to cancel the timing
8 AUX on/off:Under the power on status, press timing button for 5 seconds to start anxiliary
electrical heating, press timing button for 5 seconds again to off the AUX fuction (available to be
with AUX function units, This section is for engineers only.).
Water inlet temp. Water outlet temp.
Standby mode
Ambient temperature
Cooling mode
9 Display Lock:Press and synchronously for 5s, symbol comes out, it means all buttons
on the display are locked, but it can be unlocked after pressing both and synchronously for 5s.
Remarks:When FROST connecting with GND, the heat symbol will flash, defrost function will be disabled.
Disconnecting FROST and GND, then the heat symbol won t flash and the heat symbol under
auto-mode will disappear.
7 Parameter scan:press button for 5 seconds to enter parameter scan, press button again to
see the correspond parameter(P1: system coil temperature ;P2: reservation;Room: ambient temperature).
5 Clock setting. Press button and the bit hour and minute is flicking, press button again,
the bit hour flick, press to adjust the setting of hour. Then press button and the bit minute
flick. Press buttons to adjust the setting of minute. Press button again to complete and
exit the time setting mode.
4 Water input temp. Setting: on standby or power on status, press or button to adjust the setting of water input temp.(The inlet water temp. corresponds to the mode)
-
SWIMMING POOL HEAT PUMP
12
10) These settings are for Engineers only, please call if you require to change eny of the Optional
Parameters.
Under the power on or standby status, press and buttons at the same time for 10 seconds
to enter Operation Parameter setting interface. Press again to view 0-A parameter,
press or button to set data you need. Parameter setting as below:
parameter 00water inlet temp.setting Under cooling mode
(8-28 )default setting:27range:
MINMIN
MINMIN
Parameter 01water inlet temp. Setting Underheating moderange:(15-40default setting:27
Parameter 02Defrost cycle
default setting:45minrange:(30-90 min)
Parameter 03
range:(-30-0 )
The temp. Setting to enter defrost model
default setting:-3
Parameter 04The temp. setting to exit defrost modelrange: (2-30 )default setting:13
Parameter 05Max. Drange:
efrosting time (1-12min)
default setting:8 min
Parameter 06System quantity1:1system setting2:dual system settingdefault setting:1
Parameter 07Save setting after failure0(no)1(yes)default setting:1
Parameter 08Model selection0(cooling)1(cooling&heating)2(auxiliary elec heating) +heat pump3(heating only)
Parameter 09working mode of water pumprange:(0 or 1)default setting:1
Auto mode water inlet temp.default settingtemp.27
-
SWIMMING POOL HEAT PUMP
13
IV Maintenance1 To check the water supply device and the releaser often. You should avoid the condition of no water or air enter into system, or that will influence unit's performance and reliability. You should clear the water filter regularly to avoid unit's damage by filter's jam.2 There should be dry, sanitary and ventilation around the units. To clean the side heating exchanger regularly for keeping good heating exchanging and saving energy.3 To check the operation of every process in the unit, the operation pressure of the refrigerant system. You should maintain or change it in time.4 To check the power supply and cable connection often, there is abnormal action or bad smell about the electrical component. If there is, please maintain or change it in time.5 Please discharge all water in the water pump and water system lest freeze the water pump or water system. You should discharge the water at the bottom of water pump if the units will stop for long time. And you should check the units thoroughly and fill the system with water fully before power on the units again.
Water inlet temp. Setting(cooling mode)00
01
02
03
04
05
06
07
08
09
A
Digit meaning range default Adjust
Water inlet temp. Setting(heating mode)
Defrost cycle
The temp. setting to enter defrost model
The temp. setting to exit defrost model
Defrosting time
System quantity
Automatic restarting
Model selection
working mode of water pump
auto mode(return water temp.) Adjusted by technicians
Adjust
Adjust
Adjusted by technicians
Adjusted by technicians
Adjusted by technicians
Double system unit default(2)
Adjusted by technicians
Adjusted by technicians
Adjusted by technicians
Adjusted by technicians
8 30
15 40
30 90MIN
-30 0
2 30
1 12MIN
1 2
0 1
0 3
0 1
8 40
27
27
45 MIN
-3
13
8 MIN
1
1
1
0
27
1)Notice:above data setting 00 is relevant to cooling only. All other data(01-05)is relevant to heating mode.Remarks:parameter 03 -30~0 means from -30 to 0parameter 06 1:1 system set 2:dual system setparameter 08 0:cooling 1:cooling&heating 2:auxiliary electrical + heat pump (Auto mode can be selected) 3:heating onlyparameter: 09 0:always working 1:water pump starts working for 1 min before the compressor starts to work, water pump stop working after the compressor stop working for 30 secretary.
3. Operation Data Setting
-
Ordinary malfunctions and solution
The first time freezing protection in winter
The second time freezing protection in winter
Malfunction of systemwhen the controller with
Flow switch failure
Malfunction of systemwhen the controller with
Reason ResolutionMalfunction Display
code
Coil1 sensor failure
Coil2 sensor failure
Temp is too much different between water-in and water-out
Water inlet temperature
sensor failure
Ambient temp. Sensor
failure
Anti freezing under cooling mode
Water outlet temperature
sensor failure
3 times of excessive temp. Differentials of inlet water and outlet water in 30 minutes
defrosting
Communication failure
PP 01
PP 02
PP 03
PP 04
PP 05
PP 06
PP 07
PP 07
PP 07
EE0 1
EE0 2
EE 03
EE0 5
EE 08
Defrost codedisplay
The sensor is open or short circuit
The sensor is open or short circuit
not enough water flow
volume &water pressure
difference is too low
Water flow volume is not
enough
Low pressure switch protection
High pressure switch protection
Out side environment temperature is below 0 under stand by status.
Out side environment temperature is below 0 under stand by status.
No water/little water flow volume too small in water system.
Water flow volume not enough, water pressure difference is too low
Wire controller and ThePCB connection failure.
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check the water flow volume,
or water system is jammed or not
Check the water flow volume,
or water system is jammed or not
The system recover automatically after running antifreeze process.
The system recover automatically after running antifreeze process.
Check whether the pressure switch and water cycle system.
Check whether the pressure switch and water cycle system.
Check the water flow volume,water pump is failure or not.
Check the water flow volume,or water system is jammed or not.
Check the wire connection
The sensor is open or short circuit
The sensor is open or short circuit
The sensor is open or short circuit
Phase lack or phase error of power supply when the controller with(MK3065+MK3023(controller model)
1 Emergent switch open2 Phase lack or phase error of power supply(only for threephase unit)
1 Check emergent switch,2 Check power supply(only for three phase unit)
EE0 4
SWIMMING POOL HEAT PUMP
14
-
1. Connection of PCB(1)Controller model:MK3065
131415161718192021222324252627
MK3065
2930
3132
3334
3536
3738
Symbol MeaningCompressor of system (220VAC)
NO .
4way valve of system(220VAC)
Fan motor(220VAC/5A)
Water pump(220VAC/5A)
LCD/LED Wire controller
Water in temperature
OUT1OUT2OUT3OUT4OUT5
CN1CN2
CN3
CN4
AC-N
13/14/15
16/17
18/19
20/21
22/23
24/25
26/27
29/30
31/32
33/34
35/36
37/38
Electrical heating
Water out temperature
Pipe temperature
Ambient temperature
Power supply(AC-N)
Transformer primary coils
Transformer secondary coils
Mode switch
High voltage switch
Low voltage switch
Water flow switch
Emergency switch
Phase sequence protection switch
Reservation
2. Wiring diagram1)Controller model:MK3065
4-way valve
Transformer
Ambient temp.
Water in temp.
Pipe temp.
Water out temp.
Mo
de
sw
itch
Hig
h p
ressu
re s
witc
h
Lo
w p
ressu
re s
witc
h
Wa
ter flo
w s
witc
h
Reservation
LC
D/L
ED
w
ire c
on
trolle
r
Em
erg
en
cy s
witc
h
220V/50HzPower inputPower input
Compressor
L N 1 2L N 1 2
C
R S
Red
Blu
e
Wh
ite
Capacitance
Ca
pa
cita
nce
Red
Orange
Fan
Pump outputPump output220V/50Hz
Re
d
Red
Ora
ng
e
Blu
eY
ello
w
MK3065
Ph
ase
se
qu
en
ce
p
rote
ctio
n s
witc
h
Red
Red
Red
Yellow/green
Reservation
Blu
e
Suitable for MALCRW(008ZA/ 010ZA/ 015ZA/ 018ZA/ 020ZA/ 023ZA/ 025ZA),MALCRW(008ZA1/ 010ZA1/ 015ZA1/ 018ZA1/ 020ZA1/ 023ZA1/ 025ZA1), MALCRW (020ZB/ 023ZB/ 025ZB)
Remarks This wiring diagram is for reference only. The actual wiring is subject to the actual unit.
SWIMMING POOL HEAT PUMP
Attachment 1
15
-
Remarks This wiring diagram is for reference only. The actual wiring is subject to the actual unit.
Suitable for MALCRW(027ZA/ 030ZA/ 045ZA), MALCRW(027ZA1/ 030ZA1/ 045ZA1).MALCRW(027ZB/ 030ZB)
4-way valve
Transformer
Ambient temp.
Water in temp.
Pipe temp.
Water out temp.
Mo
de
sw
itch
Hig
h p
ressu
re s
witc
h
Lo
w p
ressu
re s
witc
h
Wa
ter flo
w s
witc
h
Reservation
LC
D/L
ED
w
ire c
on
trolle
r
Em
erg
en
cy s
witc
h
220V/50Hz
Power inputPower input
L N 1 2L N 1 2
Compressor
C
R S
Blu
e
Wh
ite
Capacitance
Ca
pa
cita
nce
Red
Orange
Fan
Pump outputPump output
220V/50Hz
Blu
e
Red
Ora
ng
e
Blu
eY
ello
w
MK3065
Ph
ase
se
qu
en
ce
p
rote
ctio
n s
witc
h
Red
Red
RedYellow/green
Red
Contactor
RedRed
Re
d
2930
3132
3334
3536
3738
Reservation
2)Controller model:MK3065( )Reversal Defensible Relay
Suitable for MALCRW(035ZA/ 040ZA/045ZA), MALCRW(035ZA1/ 040ZA1/045ZA1), MALCRW(035ZB/ 040ZB)
131415161718192021222324252627
4-way valve
Transformer
Ambient temp.
Water in temp.
Pipe temp.
Water out temp.
Mo
de
sw
itch
Hig
h p
ressu
re s
witc
h
Lo
w p
ressu
re s
witc
h
Wa
ter flo
w s
witc
h
Reservation
LC
D/L
ED
w
ire c
on
trolle
r
Em
erg
en
cy s
witc
h
220V/50Hz
Power inputPower input
L N 1 2L N 1 2
C
Ca
pa
cita
nce
Red
Orange
Fan
Pump outputPump output220V/50Hz
Blu
e
Red
Ora
ng
e
Blu
eY
ello
w
MK3065
Ph
ase
se
qu
en
ce
p
rote
ctio
n s
witc
h
Red
Red
Red
Yellow/green
Red
Contactor
RedRed
Re
d
2930
3132
3334
3536
3738
Blue
CompressorBlue
S
R
Running Capacitor
Starting Capacitor
Starting Relay
RR ff
Blue
Red
Reservation
Remarks This wiring diagram is for reference only. The actual wiring is subject to the actual unit.
SWIMMING POOL HEAT PUMP
16
-
Remarks The dotted line applicable part: MALCRW(050ZA/S / 060ZA/S),MALCRW(050ZA1/S / 060ZA1/S)
This wiring diagram is for reference only. The actual wiring is subject to the actual unit.
Suitable for MALCRW(025ZA/S / 030ZA/S / 035ZA/S / 040ZA/S / 045ZA/S / 050ZA/S / 060ZA/S), MALCRW(035ZA1/S / 040ZA1/S / 045ZA1/S / 050ZA1/S /060ZA1/S), MALCRW(035ZB/S / 040ZB/S / 045ZB/S / 050ZB/S / 060ZB/S)
Hig
h p
ressu
re s
witc
h
LC
D/L
ED
w
ire c
on
trolle
r4-way valve
Transformer
Ambient temp.
Water in temp.
Pipe temp.
Water out temp.
Mo
de
sw
itch
Lo
w p
ressu
re s
witc
h
Wa
ter flo
w s
witc
h
Reservation
Em
erg
en
cy s
witc
h
Ca
pa
cita
nce
Pump output220VAC/1PH/50Hz
Re
d Blue
Red
Red
Orange
Fan
Ora
ng
e
Blu
eY
ello
w
MK3065
RedRed
Yellow/green
Red
Red
3 phase testing PCB
RLY1
R
S
T
CP4
CP3
MK3023MK3023
L N L N
3 phase Power input (380VAC/3PH/ 50HZ)
R S T NR S T N
Compressor
Co
nta
cto
r
T1 T2 T3
L1 L2 L3
Yellow/green
Bla
ck
Wh
ite
Re
d
Bla
ck
Wh
ite
Red
Orange
Fan
Ye
llow
/gre
en
Ye
llow
/gre
en
Ca
pa
cita
nce
Black Black
White White
Reservation
3)Controller model:MK3065+MK3023
SWIMMING POOL HEAT PUMP
17
-
SWIMMING POOL HEAT PUMP
18
If you are having a problem with your pool heater, FIRST perform the consumer troubleshooting steps
detailed in your pool heater Owners Manual then CALL THE INSTALLING DEALER and have him verify
that the cause is NOT external to your pool heater (such as tripped breaker, clogged pool filter, inadequate
pump run time ,etc.)
1. Provide your Dealer with the following information:
A. Serial # located on back panel nameplate of your pool heater.
B. Proof of Installation Date(Bill of sale or original invoice only)
C. Description of the Symptoms
Will Never Need Freon
Unless your pool heater has a leak in the sealed refrigeration system, the factory charge of freon should last
for the life of the unit. Freon is very stable and should not degrade or breakdown even under severe operating
conditions. If your unit needs freon, then it has a leak, and adding freon will not solve the problem. The leak
must be located and repaired. Fortunately, freon leaks are very uncommon and usually are due to shipping.
For Installing Dealer
If your customer is having a problem with your pool heater and you as the installing dealer have
verified that the cause is NOT external to your pool heater(such as tripped breaker, clogged pool filter,
inadequate pump run time, etc.)following these steps will help you obtain the fastest service possible
for your customer.
1. Help your customer gather the following information:
A. Serial # located on back panel nameplate of your pool heater.
B. Proof of Installation Date(Bill of sale or original invoice only)
Attachment 2How to obtain Service
For Pool Owner
-
19
SWIMMING POOL HEAT PUMP
Common Units ConversionLinear Measure1 inch=25.4 millimetres
1 foot=12 inches=0.3048 metre
1 yard=3 feet=0.9144 metre
1 (statute)mile=1760 yards=1.609 kilometres
1 nautical mile=1852 m.
Square Measure1 square inch=6.45 sq.centimetres
1 square foot=144 sq.in.=9.29 sq.decimetres
1 square yard=9 sq.ft.=0.836 sq.metre
1 acre=4840 sq.yd.=0.405 hectare
1 square mile=640 acres=259 hectares
Cubic Measure1 cubic inch=16.4 cu.centimetres
1 cubic foot=1728 cu.in.=0.0283 cu.metre
1 cubic yard=27 cu.ft.=0.765 cu.metre
Capacity MeasureBritich
1 pint 20 fluid oz.=34.68 cu.in.=0.568 lite
1 quart=2 pints=1.136 litres
1 gallon=4 quart=4.546 litres
1 peck=2 gallons=9.092 litres
1 bushel=4 pecks=36.4 litres
1 quarter=8 bushels=2.91 hectolitres
American dry
1 pint=33.60 cu.in.=0.550 litre
1 quart=2 pints=1.101 litres
1 peck=8 quarts=8.81 litres
1 bushel=4 pecks=35.3 litres
American liquid
1 pint=16 fluid oz.=28.88 cu.in.=0.473 litre
1 quart=2 pints=0.946 litre
1 gallon=4 quarts=3.785 litres
Avoirdupois Weight1 grain=0.065 gram
1 dram=1.772 grams
1 ounce=16 drams=28.35 grams
1 pound=16 ounces=7000 grains=0.4536 kilogram
1 stone=14 pounds=6.35 kilograms
1 quarter= 2 stones=12.70 kilograms
1 hundredweight=4 quarters=50.80 kilograms
1 short ton=2000 pounds=0.907 tonne
1 (long)ton=20 hundredweight=1.016 tonnes
energy power1 usrt= 3024 kcal/h=3516 w
1 kcal/h=1.163 w
1 kw= 860 kcal/h
1 btu/h=0.293 w
velocity, flux1 m/s=196.85 fpm
1 cfm=1.699 cmh
1 gpm= 0.27276 cmh
1 gpm= 0.2271 cmh
Pressure1 bar=100000 pa
1 psi=0.0703 kgf/cm2
1 kgf/cm2=98000 pa
1 mm aq.=9.8 pa
1 mm hg=133.28 pa
1 m H2O=9800 pa=0.1 kgf/cm2
-
SWIMMING POOL HEAT PUMP