code information solar individual permit package ten… · 12-11-2019 · karen miguel 4551...
TRANSCRIPT
SHEET
SATELLITE IMAGE
JOB NOTES
CO
VER
SH
EET
PVA-0
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
12-11-2019
MAOLIVAR
12-11-2019
PROJECT LOCATION
NTS
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
R E V I S I O N S
SO
LAR I
ND
IVID
UAL
PERM
IT P
ACKAG
E
GRID
-TIE
D P
HO
TOVO
LTAIC
SYS
TEM
REV DESCRIPTION DATE DB CB
PROJECT
INSTALLER
KAREN
MIG
UEL
4551
TEN
DER
FOO
T W
AY
LOT
921
WIC
KEN
BU
RG
, ARIZ
ON
A 8
5390
-452
6
RP-98354
8.18
kW
SPRI - PHOENIX
TYLER BOSHARD
C A
L
I C
E N
S E
#
8 9
0 8
9 5
8.0
kW A
C M
AX.
CO
NTI
NU
OU
S O
UTP
UT
POW
ER
GRID-TIED PHOTOVOLTAIC SYSTEM
SOLAR INDIVIDUAL PERMIT PACKAGE
KAREN MIGUEL
4551 TENDERFOOT WAY LOT 9217143293994
WICKENBURG, ARIZONA 85390-4526
8.18 kW
AHJ: WICKENBURG
UTILITY: ARIZONA PUBLIC SERVICE CO
8.0 kW AC MAXIMUM CONTINUOUS OUTPUT POWER
CODE INFORMATION
APPLICABLE CODES, LAWS AND REGULATIONS
2015 INTERNATIONAL BUILDING CODE (IBC)2015 INTERNATIONAL RESIDENTIAL CODE (IRC)2015 INTERNATIONAL FIRE CODE (IFC)2014 NATIONAL ELECTRIC CODE (NEC)
PV SOLAR ARCHITECTURAL DRAWINGS
SHEET INDEX
PV SOLAR ELECTRICAL DRAWINGS
PVE-1 ELECTRICAL THREE-LINE DIAGRAM &
PVE-2 ELECTRICAL CALCULATION
PVE-3 ELECTRICAL DATA & SPECIFICATIONS
SPECIFICATIONS
PVE-4 PLACARD / EQUINOX GROUNDING DETAILS
PVE-5 BRANCH DIAGRAM
PV SOLAR STRUCTURAL DRAWINGS
PVS-1 MOUNTING DETAILS
PVA-0 COVER SHEET
PVA-1 ARRAY LAYOUT
85'-5"51'-1
1"
TO ELECTRIC
UTILITY GRIDA
C
D
P
V
M
N
-
L
C
TEND
ERFO
OT W
AY
SHEET
ARRAY
LAYO
UT
PVA-1
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
12-11-2019
MAOLIVAR
12-11-2019
ROOF TYPE
CONTRACT MODULE
MICROINVERTER
STORY
SYSTEM
ROOF PITCH
& QUANTITY
TYPE & QUANTITY
HOME TYPE
ORIENTATION
CONSUMPTIONMONITORING TBD
ROOF ATTACHMENTQUANTITY
FLAT TILE
5:12
1 - STORY
217°
SPR-E20-327-E-AC (240) (25)
IQ7XS-96-ACM-US (240)) (25)
46
1/16" = 1'-0"
L E G E N D
JUNCTION BOX
EXISTING SERVICE POINTAND UTILITY METERING
PROPERTY LINE
3' WIDE ACCESS PATH
CONDUIT
ACDPV UTILITY DISCONNECT
N-LC NEW LOAD CENTER
PV METERPV
M
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
R E V I S I O N S
SO
LAR I
ND
IVID
UAL
PERM
IT P
ACKAG
E
GRID
-TIE
D P
HO
TOVO
LTAIC
SYS
TEM
REV DESCRIPTION DATE DB CB
PROJECT
INSTALLER
KAREN
MIG
UEL
4551
TEN
DER
FOO
T W
AY
LOT
921
WIC
KEN
BU
RG
, ARIZ
ON
A 8
5390
-452
6
RP-98354
8.18
kW
SPRI - PHOENIX
TYLER BOSHARD
C A
L
I C
E N
S E
#
8 9
0 8
9 5
8.0
kW A
C M
AX.
CO
NTI
NU
OU
S O
UTP
UT
POW
ER
NOTE: UTILITY HAS 24-HR UNRESTRICTEDACCESS TO ALL PHOTOVOLTAIC SYSTEMCOMPONENTS LOCATED AT SERVICEENTRANCE.
NOTE: REFERENCE SECTION 301.15 OF THEAPS ESRM FOR ELECTRIC METERSEPARATION BETWEEN WATER AND GAS.
NOTE: WORKSPACE IN FRONT OF ACELECTICAL SYSTEM COMPONENTS SHALLBE IN ACCORDANCE WITH APS AND NECREQUIREMENS. FOR APSREQUIREMENTS, REFERENCE SECTION300 OF THE APS ESRM AND SECTION 8.2OF THE APS INTERCONNECTIONREQUIREMENTS.
NOTE: NO FENCES OR GATES RESTRICTING ACCESS TO UTILITY METER AND APS EQUIPMENT.
NOTE:1. FIELD ADJUSTMENTS OF FEWER
THAN 6” MAY BE ALLOWED BASED ON SITECONDITIONS AND MEASUREMENTS.
N
FIGURE 3: MOUNTING CLAMPPOSITIONING DETAILSTABLE 2: PENETRATION GUIDE FOR INSTALL
STACKED STAGGERED FULLY STAGGERED
STACKED/STAGGEREDFULLY STAGGERED
*CHECK TABLE 1 FOR MAX.. PENETRATION SPACING AND PENETRATION PATTERN FOR EACH ARRAY.
TWO OR MORE ROWS OF MODULES
ONE ROW OF MODULES
96 CELL MODULE
·RAILS SHALL BE POSITIONED IN THE NON-CROSSHATCHED REGIONS
TABLE 1 – ARRAYS INFORMATION
ROOF
PITCH
ROOFING
TYPE
ATTACHMENT
TYPE
NO. OF
STORIES
FRAMING
TYPE
FRAMING
SIZE
O.C.
SPACING
MAX.
RAFTER
SPAN
PENETRATION
PATTERN
MAX.
ATTACHMENT
SPACING
MAX. RAIL
OVERHANG
ROOF 1 22° Flat Tile Pegasus Tile 1 Wood Truss 2x4 2' 8' Stacked 6' 2'
ROOF 2 -- -- -- -- -- -- -- -- -- -- --
ROOF 3 -- -- -- -- -- -- -- -- -- -- --
ROOF 4 -- -- -- -- -- -- -- -- -- -- --
ROOF 5 -- -- -- -- -- -- -- -- -- -- --
ROOF 6 -- -- -- -- -- -- -- -- -- -- --
CHECK TABLE 2 FOR PENETRATION PATTERN GUIDE
FIG 1: ROOF 1 STRUCTURAL FRAMING DETAIL FIGURE 2: INVISIMOUNT WITH PEGASUS SOLAR ROOF ATTACHMENT DETAILS @ TRUSS / RAFTERS
PV MODULE PV MODULE
SHEET
STR
UCTU
RAL
INFO
RM
ATI
ON
AN
D M
OU
NTI
NG
DET
AIL
S
PVS-1
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
12-11-2019
MAOLIVAR
12-11-2019
NTS
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
R E V I S I O N S
SO
LAR I
ND
IVID
UAL
PERM
IT P
ACKAG
E
GRID
-TIE
D P
HO
TOVO
LTAIC
SYS
TEM
REV DESCRIPTION DATE DB CB
PROJECT
INSTALLER
KAREN
MIG
UEL
4551
TEN
DER
FOO
T W
AY
LOT
921
WIC
KEN
BU
RG
, ARIZ
ON
A 8
5390
-452
6
RP-98354
8.18
kW
SPRI - PHOENIX
TYLER BOSHARD
C A
L
I C
E N
S E
#
8 9
0 8
9 5
8.0
kW A
C M
AX.
CO
NTI
NU
OU
S O
UTP
UT
POW
ER
NO
EGC: BARE Cu #6
BRANCH CIRCUITFROM PV ARRAY TO
JUNCTION BOX
AC MODULES NOTES:1. DC CIRCUIT IS ISOLATED AND INSULATED FROM GROUND AND MEETS THE REQUIREMENT OF NEC 690.35.2. SUNPOWER PROVIDED CABLES COMES WITH TWO (2) #12 AWG WIRE AND THIS IS BY DESIGN. NEUTRAL AND
ADDITIONAL GROUND WIRE IS NOT REQUIRED FOR PROVIDED TRUNK AND EXTENSION CABLES.3. SUNPOWER AC MODULES HAVE BEEN TESTED AND CERTIFIED TO UL 2703 FOR INTEGRATED GROUNDING AND
HENCE A SEPARATE GROUND WIRE IS NOT REQUIRED WITHIN THE ARRAY.4. USE ROW-TO-ROW GROUNDING CLIP PROVIDED TO GROUND ROWS OF MODULE. BOND SUB-ARRAYS BY
RUNNING #6 AWG BARE CU WIRE AND GROUND LUGS AT A SINGLE POINT ON EACH SUB-ARRAY AND THEN TOTHE JUNCTION BOX. REFER TO PVE-4 FOR ADDITIONAL DETAILS.
NOTE:BELOW ARE OPTIONAL OFFERINGS AND SHALLONLY BE INSTALLED IF THE HOMEOWNER SIGNSA SPECIFIC CONTRACT WITH SUNPOWER:· SUNPOWER MONITORING SYSTEM
ELECTRICAL NOTES:1. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC.2. ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS.3. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENT TO BE INSTALLED.4. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS.5. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.6. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING NEC
REQUIREMENTS.7. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY 3RD PARTY.8. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.9. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT.10. EQUIVALENT SPECIFICATION ON CABLES AND ELECTRICAL EQUIPMENT SPECIFIED ARE ACCEPTABLE.11. AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT
REQUIRED.
1EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THENEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVINGELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITYHAVING JURISDICTION.
2BI-DIRECTIONAL UTILITY METER TO BE INSTALLED BY UTILITYCOMPANY.
3LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH".SWITCH COVER TO BE LOCKED AT ALL TIMES. SWITCH TO BEVISUAL OPEN AND ACCESSIBLE PER UTILITY REQUIREMENTS ANDCONFORM TO NEC 705.22
4LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH: PERNEC 690.14(C)(2). LABEL WITH OPERATING CURRENT,OPERATING VOLTAGE MAXIMUM SYSTEM VOLTAGE, AND SHORTCIRCUIT CURRENT PER NEC 690.53 SWITCH TO BE LOCKED PERNEC 690.70(D)
5LABEL" PHOTOVOLTAIC POWER SYSTEM DEDICATED KWHMETER".METER ENCLOSURE AND SOCKET PROVIDED ANDINSTALLED BY CUSTOMER PER APS ESRM.METER PROVIDED BYCUSTOMER.
6PROVIDE WARNING SIGN PER NED 690.17 READING"WARNING-ELECTRIC SHOCK HAZARD-DO NOT TOUCHTERMINALS-TERMINALS ON BOTH LINE AND LOAD SIDES MAY BEENERGIZED IN THE OFF POSITION.
7METALLIC CONDUIT SHALL BE USED WITHIN BUILDING PER NEC690.31(E)
8LABEL "DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL"AND " LOADS NOT TO BE ADDED TO THIS PANEL.
9GEC TO BE INSTALLED AS REQUIRED BY MANUFACTURERINSTRUCTIONS AND NED 690.47.
10GROUNDING BUSHINGS AT EVERY ENTRY AND EXIT POINT TOENCLOSURES WITH RMC
11A PLACARD OR DIRECTORY IS INSTALLED AT THE SERVICEENTRANCE WITH EXPLICIT DIRECTIONS TO THE LOCATION OFTHE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH ASREQUIRED BY APS.
12A PERMANENT PLACARD OR DIRECTORY IS INSTALLED PER NEC705.10
13SUPPLY SIDE CONNECTION IS INSTALLED PER NEC 230 APS,ESRM AND APS INTERCONNECTION REQUIREMENTS, LABELPHOTOVOLTAIC SYSTEM SERVICE DISCONNECT SWITCH, SWITCHCOVER TO BE LOCKED AT ALL TIMES.
14SUPPLY SIDE CONNECTIONS IS INSTALLED IN ACCORDANCEWITH MANUFACTURERS INSTRUCTIONS. DOCUMENTATION ISINCLUDED WITH THE APS INTERCONNECTION APPLICATION.ENSURE UL LISTED CONNECTORS.
15LABEL WARNING - A GENERATION SOURCE IS CONNECTED TOTHE SUPPLY (UTILITY) SIDE OF THE SERVICE OF THE SERVICEDISCONNECTING MEANS. FOLLOW PROPER LOCKOUT/ TAGOUTPROCEDURES TO ENSURE THE PHOTOVOLTAIC SYSTEM UTILITYDISCONNECT SWITCH IS OPENED PRIOR TO PERFORMING WORKON THIS DEVICE.
16EQUIPMENT SHALL BE LISTED, TESTEDAND MARKED TOWITHSTAND THE AVAILABLE SHORT CIRCUITCURRENT
CHECK BOX FOR WHETHER SYSTEM IS GROUNDED ORUNGROUNDED:
GROUNDED (INCLUDE GEC)UNGROUNDED
FOR UNGROUNDED SYSTEMS:· DC OCPD DISCONNECT BOTH CONDUCTORS OF EACH
SOURCE CIRCUIT.· UNGROUNDED CONDUCTORS MUST BE IDENTIFIED PER
210.5(C). WHITE FINISHED CONDUCTORS ARE NOTPERMITTED.
TAG
1
2
3
4
5
6
7
8
9
DC / DC CONVERTERS
SOURCE CIRCUIT JUNCTION BOX
SEPARATE DC DISCONNECT
INTERNAL INVERTER DC DISCONNECT
STRING INVERTER
SOLAR LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
NO
NO
YES--
1
SOLAR AC MODULE / BRANCH ACM
SUNPOWER PROVIDED AC MODULES EXTENSIONCABLE, LISTED AS AN ASSEMBLY
NO
NO
#12 2
1
A
DC
AC
DC
AC
DC
AC
1SUNPOWER MODULES
AC MODULEEXTENSION CABLE
AC MODULEEXTENSION CABLE
AC MODULEEXTENSION CABLE
7 AC MODULESBranch Circuit # 3
8 AC MODULESBranch Circuit # 2
10 AC MODULESBranch Circuit # 1
SPR-E20-327-E-AC (240)
GROUNDING ELECTRODEGROUND ROD
H
INCOMING SOURCE FEED
, 120/240V, 1PH, 3W
TOP FED
MCB *MSP MAX PV BREAKER (A) =
x 120% - =
LOCATION:
MANUF: (E) UTILITYBIDIRECTIONAL
METER #:
(E) MAIN SERVICE PANEL
TO HOUSELOADS
L1L2N
GN
D
PV BREAKER: TO BEINSTALLED ON THE OPPOSITE SIDE
OF THE MAIN OCPD OF THE BUSS
225A 200A, 2P70A, 2P
225A
200A, 2P
RIGHT EXT. WALL
SQUARE D
DH4610
50A, 2P
BRANCH CIRCUIT SUMMARY
BRANCH # ROOF LOCATION
1
2
3
4
5
6
ROOF 1
ROOF 1
ROOF 1
- -
- -
- -
B
THWN-2
EGC: THWN-2
6
1
JUNCTION BOX,NEMA-3R
3
3/4"EMT#10
#8
PVS6
CPCT
D
1
2
#14
#14
#22
THWN-2
AWG TWISTED PAIRAWG TWISTED PAIR
EGC: THWN-2
#14
#14
#22
3
1/2"1/2"
1/2"EMT
EMT
ETHERNETCONNECTION TO
DSL/CABLE MODEM
CAT5e
CCT
15A, 2P
9
YES
THWN-2
EGC: THWN-2
3
1
E
WITH VISIBLE KNIFE BLADES
SQUARE D LOCATED OUTSIDE
GND
E
PV UTILITY DISCONNECT SWITCH
#8
#10EMT 3/4"
DU222RB OR EQUIVALENTUTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &CONDUCTOR TYPE
CONDUCTOR SIZE(AWG) CONDUIT/CABLE TYPE
A
TAG CONDUIT SIZENUMBER OFCONDUCTORS
B
C
D
E
L1L2NGN
D
7
YES
MIN., 120/240V,LOCATION:
MLO
20A, 2P
20A, 2P
20A, 2P
NEAR MSP100 A
(N) SOLAR LOAD CENTER
M
YES
8*MILBANK 100A, 1Ø, 3W,
U5929-XL-INS, 4-JAW, FORM 2S
MICROINVERTER MODEL:IQ7XS-96-ACM-US (240)
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
FIGURE A: THREE LINE DIAGRAM -
ELEC
TRIC
AL
THREE
-LIN
E D
IAG
RAM
& S
PECIF
ICATI
ON
S
12-11-2019
MAOLIVAR
12-11-2019
8.18 kW
SHEET
PVE-1
NTS
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
R E V I S I O N S
SO
LAR I
ND
IVID
UAL
PERM
IT P
ACKAG
E
GRID
-TIE
D P
HO
TOVO
LTAIC
SYS
TEM
REV DESCRIPTION DATE DB CB
PROJECT
INSTALLER
KAREN
MIG
UEL
4551
TEN
DER
FOO
T W
AY
LOT
921
WIC
KEN
BU
RG
, ARIZ
ON
A 8
5390
-452
6
RP-98354
8.18
kW
SPRI - PHOENIX
TYLER BOSHARD
C A
L
I C
E N
S E
#
8 9
0 8
9 5
8.0
kW A
C M
AX.
CO
NTI
NU
OU
S O
UTP
UT
POW
ER
ELECTRICAL CALCULATIONS
ROOF JCT BOX TO SUB-PANEL WIRING -BRANCH 1 #10 ROOF JCT BOX TO SUB-PANEL WIRING -
BRANCH 2 #10 ROOF JCT BOX TO SUB-PANEL WIRING -BRANCH 3 #10 SUB-PANEL TO GRID-TIE WIRING #8
NUMBER OF MODULES PER BRANCH CIRCUIT 10 NUMBER OF MODULES PER BRANCH CIRCUIT 8 NUMBER OF MODULES PER BRANCH CIRCUIT 7 VOLTAGE 240 V
VOLTAGE 240 V VOLTAGE 240 V VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 32.75 A
BRANCH CURRENT: IOUT = 13.10 A BRANCH CURRENT: IOUT = 10.48 A BRANCH CURRENT: IOUT = 9.17 A MINIMUM WIRE AMPACITY: IMAX =IOUT_TOTAL x 1.25 40.94 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x1.25 16.38 A MINIMUM WIRE AMPACITY: IMAX = IAC_OUT
x 1.25 13.10 A MINIMUM WIRE AMPACITY: IMAX = IAC_OUTx 1.25 11.46 A CONDUCTOR DE-RATING
CONDUCTOR DE-RATING CONDUCTOR DE-RATING CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 46°C
MAXIMUM AMBIENT TEMPERATURE 46°C MAXIMUM AMBIENT TEMPERATURE 46°C MAXIMUM AMBIENT TEMPERATURE 46°C TEMPERATURE USED FOR AMPACITYDE-RATING 46°C
TEMPERATURE ADDER 22°C TEMPERATURE ADDER 22°C TEMPERATURE ADDER 22°C TEMPERATURE DE-RATING COEFFICIENT 0.82TEMPERATURE USED FOR AMPACITYDE-RATING 68°C TEMPERATURE USED FOR AMPACITY
DE-RATING 68°C TEMPERATURE USED FOR AMPACITYDE-RATING 68°C FILL DE-RATING COEFFICIENT 1.0
TEMPERATURE DE-RATING COEFFICIENT 0.58 TEMPERATURE DE-RATING COEFFICIENT 0.58 TEMPERATURE DE-RATING COEFFICIENT 0.58 IWIRE_MIN = IMAX / TEMP_COEFF /FILL_COEFF 49.92 A
FILL DE-RATING COEFFICIENT 0.8 FILL DE-RATING COEFFICIENT 0.8 FILL DE-RATING COEFFICIENT 0.8 WIRE SIZE SELECTED BASED ON AMPACITY #8IWIRE_MIN = IMAX / TEMP_COEFF /FILL_COEFF 35.29 A IWIRE_MIN = IMAX / TEMP_COEFF /
FILL_COEFF 28.23 A IWIRE_MIN = IMAX / TEMP_COEFF /FILL_COEFF 24.70 A WIRE SIZE AMPACITY 55A
WIRE SIZE SELECTED BASED ON AMPACITY #10 WIRE SIZE SELECTED BASED ON AMPACITY #10 WIRE SIZE SELECTED BASED ON AMPACITY #10 CONDUCTOR SIZE PER NEC #8
WIRE SIZE AMPACITY 40A WIRE SIZE AMPACITY 40A WIRE SIZE AMPACITY 40A CONDUCTOR SIZE ADJUSTED FOR VOLTAGEDROP #8
CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE PER NEC #10 VOLTAGE DROP AT 10 FT DISTANCE 1.15%CONDUCTOR SIZE ADJUSTED FOR VOLTAGEDROP #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE
DROP #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGEDROP #10 OVERCURRENT PROTECTION 50A, 2P
VOLTAGE DROP AT 85 FT DISTANCE 1.15% VOLTAGE DROP AT 85 FT DISTANCE 0.92% VOLTAGE DROP AT 85 FT DISTANCE 0.81% MINIMUM OCPD = IOUT x 1.25 40.94 A
OVERCURRENT PROTECTION 20A, 2P OVERCURRENT PROTECTION 20A, 2P OVERCURRENT PROTECTION 20A, 2P NEXT LARGER OCPD SIZE 50 A
MINIMUM OCPD = IOUT x 1.25 16.38 A MINIMUM OCPD = IOUT x 1.25 13.10 A MINIMUM OCPD = IOUT x 1.25 11.46 A
NEXT LARGER OCPD SIZE 20 A NEXT LARGER OCPD SIZE 20 A NEXT LARGER OCPD SIZE 20 A
SHEET
ELEC
TRIC
AL
CALC
ULA
TIO
N
PVE-2
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
12-11-2019
MAOLIVAR
12-11-2019
NTS
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
R E V I S I O N S
SO
LAR I
ND
IVID
UAL
PERM
IT P
ACKAG
E
GRID
-TIE
D P
HO
TOVO
LTAIC
SYS
TEM
REV DESCRIPTION DATE DB CB
PROJECT
INSTALLER
KAREN
MIG
UEL
4551
TEN
DER
FOO
T W
AY
LOT
921
WIC
KEN
BU
RG
, ARIZ
ON
A 8
5390
-452
6
RP-98354
8.18
kW
SPRI - PHOENIX
TYLER BOSHARD
C A
L
I C
E N
S E
#
8 9
0 8
9 5
8.0
kW A
C M
AX.
CO
NTI
NU
OU
S O
UTP
UT
POW
ER
1. MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE,WEATHER RESISTANT AND SUITABLE FOR THEENVIRONMENT.
2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITHMINIMUM 38" LETTER HEIGHT, WHITE ON RED BACKGROUND.
3. MAIN SERVICE DISCONNECT MARKING SHALL BE PLACEDADJACENT TO MAIN SERVICE DISCONNECT IN A LOCATIONCLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER ISOPERATED.
4. MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DCCONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES,AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TOAVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY10', AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS,AND AT ALL DC COMBINER AND JUNCTION BOXES.
5. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USEONLY APPROVED ADHESIVE.
SIGNAGE NOTES
ELECTRICAL DATA & SPECIFICATIONS
PHOTOVOLTAIC SYSTEM EQUIPPEDWITH RAPID SHUTDOWN
AMPS
VOLTS
PHOTOVOLTAIC POINT OFINTERCONNECTION
WARNING: DUAL POWER SOURCE.SECOND SOURCE IS PHOTOVOLTAIC
SYSTEM
SIGNAGE LOCATIONS:
· MAIN SERVICE PANEL· INDOOR / OUTDOOR SUBPANEL
MAXIMUM RATED AC OUTPUT CURRENT:
MAXIMUM OPERATING AC VOLTAGE:
SIGNAGE LOCATIONS:
· MAIN SERVICE PANEL
PV SOLAR BREAKERDO NOT RELOCATE THISOVERCURRENT DEVICE
SIGNAGE LOCATIONS:
· MAIN SERVICE PANEL· NEW INDOOR / OUTDOOR LOAD CENTER· INDOOR / OUTDOOR SUBPANEL
PHOTOVOLTAIC SYSTEMAC DISCONNECT
RATED AC OUTPUT CURRENT:
NOMINAL OPERATING AC VOLTAGE:
SIGNAGE LOCATIONS:
· INDOOR / OUTDOOR AC DISCONNECT
AMPS
VOLTS
32.75 A
240 V
32.75 A
240 V
SHEET
ELEC
TRIC
AL
DATA
& S
PECIF
ICATI
ON
S
PVE-3
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
12-11-2019
MAOLIVAR
12-11-2019
NTS
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
R E V I S I O N S
SO
LAR I
ND
IVID
UAL
PERM
IT P
ACKAG
E
GRID
-TIE
D P
HO
TOVO
LTAIC
SYS
TEM
REV DESCRIPTION DATE DB CB
PROJECT
INSTALLER
KAREN
MIG
UEL
4551
TEN
DER
FOO
T W
AY
LOT
921
WIC
KEN
BU
RG
, ARIZ
ON
A 8
5390
-452
6
RP-98354
8.18
kW
SPRI - PHOENIX
TYLER BOSHARD
C A
L
I C
E N
S E
#
8 9
0 8
9 5
8.0
kW A
C M
AX.
CO
NTI
NU
OU
S O
UTP
UT
POW
ER
A
C
D
P
V
M
N
-
L
C
FIGURE 1: SUNPOWER EQUINOX GROUNDING DETAILS
FILE: RP-98354-IP-PLSOLAR-PVE-4.dwg, USER: maolivar, DATE/TIME: Dec 11, 2019 - 7:53am
SHEET
PVE-4
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
12-11-2019
MAOLIVAR
12-11-2019
NTS
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
R E V I S I O N S
SO
LAR I
ND
IVID
UAL
PERM
IT P
ACKAG
E
GRID
-TIE
D P
HO
TOVO
LTAIC
SYS
TEM
REV DESCRIPTION DATE DB CB
PROJECT
INSTALLER
KAREN
MIG
UEL
4551
TEN
DER
FOO
T W
AY
LOT
921
WIC
KEN
BU
RG
, ARIZ
ON
A 8
5390
-452
6
RP-98354
8.18
kW
SPRI - PHOENIX
TYLER BOSHARD
C A
L
I C
E N
S E
#
8 9
0 8
9 5
8.0
kW A
C M
AX.
CO
NTI
NU
OU
S O
UTP
UT
POW
ER
POWER TO THIS BUILDING IS ALSOSUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECT(S)
LOCATED AS SHOWN:
CAUTION:
AC
DISCONNECT
PHOTOVOLTAICARRAY ON ROOF
SERVICE POINT &
UTILITY METERING
SOLAR LOAD
CENTER
PV METER
FIGURE 2: PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES
PLACARD SIGNAGE / SUNPOWER EQUINOX GROUNDING DETAILS
PLACARD
/ S
UN
POW
ER E
QU
INO
XG
RO
UN
DIN
G D
ETAIL
S
4551 TENDERFOOT WAY
NNNN
A
C
D
P
V
M
N
-
L
C
SHEET
BRAN
CH
DIA
GRAM
PVE-5
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
12-11-2019
MAOLIVAR
12-11-2019
29/256" = 1'-0"
INSTALLER NAME:
_____________________BRANCH VOLTAGES:
1.2.3.4.5.6.
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
R E V I S I O N S
SO
LAR I
ND
IVID
UAL
PERM
IT P
ACKAG
E
GRID
-TIE
D P
HO
TOVO
LTAIC
SYS
TEM
REV DESCRIPTION DATE DB CB
PROJECT
INSTALLER
KAREN
MIG
UEL
4551
TEN
DER
FOO
T W
AY
LOT
921
WIC
KEN
BU
RG
, ARIZ
ON
A 8
5390
-452
6
RP-98354
8.18
kW
SPRI - PHOENIX
TYLER BOSHARD
C A
L
I C
E N
S E
#
8 9
0 8
9 5
8.0
kW A
C M
AX.
CO
NTI
NU
OU
S O
UTP
UT
POW
ER
LEGEND & SYMBOLS:
TERMINATOR
GROUND LUG ASSEMBLY
FEMALE CONNECTOR
R2R GROUNDING CLIP
SEALING CAP
MALE CONNECTOR
JUNCTION BOX
RAW TRUNK CABLE
2.0 m. TRUNK CABLE
1.3 m. TRUNK CABLE
2.3 m. TRUNK CABLE
ONE CONNECTORPER MODULE
PV MODULE SPECIFICATION SHEET AC MODULE COMPLIANCE LETTER SHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
FIGURE 1: MODULE INSTALLATION MANUAL PAGE 1 FIGURE 2: MODULE INSTALLATION MANUAL PAGE 2SHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
FIGURE 1: MODULE INSTALLATION MANUAL PAGE 3 FIGURE 2: MODULE INSTALLATION MANUAL PAGE 4SHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
FIGURE 1: MODULE INSTALLATION MANUAL PAGE 5 FIGURE 2: MODULE INSTALLATION MANUAL PAGE 6SHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
FIGURE 1: MODULE INSTALLATION MANUAL PAGE 7SHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
FIGURE 1: INVISIMOUNT DATA SHEET FIGURE 2: CERTIFICATE OF COMPLIANCESHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
UL CERTIFICATION - MOUNTING SYSTEMS,DEVICES, CLAMPING DEVICES & GROUND LUGS FOR PV UL CERTIFICATION - MOUNTING SYSTEMS,DEVICES, CLAMPING DEVICES & GROUND LUGS FOR PVSHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
UL CERTIFICATION - MOUNTING SYSTEMS,DEVICES, CLAMPING DEVICES & GROUND LUGS FOR PVSHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
FIGURE 1: PEGASUS SOLAR MOUNTING DATA SHEET FIGURE 2: PEGASUS SOLAR MOUNTING DATA SHEET
FILE: Pegasus Solar_SPEC SHEETS.dwg, USER: reude, DATE/TIME: Mar 20, 2017 - 7:43pm
SHEET
REV DESCRIPTION DATE DB CB
R E V I S I O N S
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
SCALE
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
NTS
C A
L
I C
E N
S E
#
8 9
0 8
9 5
FIGURE 1: PEGASUS SOLAR CERTIFICATION LETTER FIGURE 2: PEGASUS SOLAR CERTIFICATION LETTER
FILE: SPD_PS_SPEC SHEETS.dwg, USER: reude, DATE/TIME: Mar 20, 2017 - 7:30pm
SHEET
REV DESCRIPTION DATE DB CB
R E V I S I O N S
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
SCALE
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
C A
L
I C
E N
S E
#
8 9
0 8
9 5
NTS
FIGURE 1: PEGASUS SOLAR CERTIFICATION LETTER FIGURE 2: PEGASUS SOLAR TEST VERIFICATION OF CONFORMITY
FILE: Pegasus Solar_SPEC SHEETS.dwg, USER: reude, DATE/TIME: Mar 20, 2017 - 7:44pm
SHEET
REV DESCRIPTION DATE DB CB
R E V I S I O N S
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
SCALE
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
C A
L
I C
E N
S E
#
8 9
0 8
9 5
NTS
FIGURE 1: PVS6X SPECIFICATION SHEET FIGURE 2: PVS6X SPECIFICATION SHEETSHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
FIGURE 1: SUNPOWER EQUINOX GROUND PATH & COMPLIANCE FIGURE 2: CURRENT TRANSFORMER SPECIFICATION SHEETSHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
R E V I S I O N SREV DESCRIPTION DATE DB CB
C A
L
I C
E N
S E
#
8 9
0 8
9 5
PROJECT
OPPORTUNITY
FILE: SQUARE D SPEC SHEETS.dwg, USER: jbernales, DATE/TIME: Jul 05, 2018 - 11:32am
SHEET
REV DESCRIPTION DATE DB CB
R E V I S I O N S
1 4
1 4
H
A R
B O
U R
W
A Y
S O
U T
H
R I
C H
M O
N D
,
C A
9 4
8 0
4
( 5
1 0
) 5
4 0
- 0
5 5
0
C O
R P
O R
A T
I O
N ,
S Y
S T
E M
S
THIS
DO
CU
MEN
T CO
NTA
INS P
RO
PRIE
TARY
INFO
RM
ATI
ON
. REP
RO
DU
CTI
ON
,D
ISCLO
SU
RE,
OR U
SE
WIT
HO
UT
SPE
CIF
IC W
RIT
TEN
AU
THO
RIZ
ATI
ON
OF
SU
NPO
WER
CO
RPO
RATI
ON
IS S
TRIC
TLY
FORBID
DEN
.
SCALE
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
C A
L
I C
E N
S E
#
8 9
0 8
9 5
NTS