Parameter setting at OMC and FSR repeater
� Comba FSR repeater is actually has 2 versions (A1version,A2 version ) for Truemove, which the both version are difference to setting parameter at OMC side and FSR side
� The following as below is method for setting after installed
Overview
� The following as below is method for setting after installed new FSR repeater and also after replaced FSR repeater
� Note: part number of FSR repeater will identify the type of version of FSR repeater
FSR A1 version parameter settingOMC side
Necessary parameter for setting
� Device type: choose “Frequency Shifting Repeaters”
� Device model: choose “ RF-1822-D02T 18H02” for Master Unit and “ RF-1822-R02T 18H02” for Remote Unit
� Site ID: can set the site ID is only 6 digits (normal character and normal No.), for example “ PCB159”
� Site sub ID: choose “0”
� Communication type: choose “ SMS”
� Device phone No.: choose number telephone of FSR
FSR A1 version parameter setting
© 2007 Comba Telecom, All Rights Reserved
� Device phone No.: choose number telephone of FSR repeater
� OMC phone No.: choose “ SMSC number”
� Device phone No. (Data): choose number telephone of FSR repeater
FSR repeater side setting by OMT V2.1
FSR A1 version parameter setting
© 2007 Comba Telecom, All Rights Reserved
Necessary parameter for setting
� SMS Center Number: choose “+6691009120”
� Alarm Report Number 1: can choose whether “ SMSC No. (94323), OMC modem No. com1 (0891030982) or OMC modem No. com7 (0891031683)”
� Site ID: the site ID at FSR must be the same with site ID at OMC “PCB159”
� Alarm report method: choose “SMS”
FSR A1 version parameter setting
© 2007 Comba Telecom, All Rights Reserved
FSR A2 version parameter settingOMC side
� Device type: choose “Frequency Shifting Repeaters”
� Device model: choose “ Frequency ShiftingRepeater(Broad)-MU(CSP3)” for Master Unit and “Frequency Shifting Repeater(Broad)-RU(CSP3)” for Remote Unit
� Site ID: have to set the site ID is 8 digits (Hex No.), for example “5045503F”
� Site sub ID: choose “FF”
Necessary parameter for setting
FSR A2 version parameter setting
� Site sub ID: choose “FF”
� Communication type: choose “ SMS”
� Device phone No.: choose number telephone of FSR repeater
� OMC phone No.: choose “ SMSC number”
� Device phone No. (Data): choose number telephone of FSR repeater
FSR repeater side setting by OMT V3.20
FSR A2 version parameter setting
© 2007 Comba Telecom, All Rights Reserved
FSR repeater side setting by OMT V3.20
FSR A2 version parameter setting
© 2007 Comba Telecom, All Rights Reserved
Necessary parameter for setting
� SMS Center Number: choose “+6691009120”
� Alarm Report Number 1: can choose whether “ SMSC No. (94323), OMC modem No. com1 (0891030982) or OMC modem No. com7 (0891031683)”
� Site ID: the site ID at FSR must be the same with site ID at OMC “5045503F”
� Site sub ID: the site sub ID at FSR must be the same with site ID at OMC “FF”
FSR A2 version parameter setting
© 2007 Comba Telecom, All Rights Reserved
with site ID at OMC “FF”
� Alarm report mode: choose “SMS”
Conclusion
Device type
Parameter type
and FSR type
A1 master unit A1 remote unit A2 master unit A2 remote unit
Device type Frequency Shifting Repeaters
Frequency Shifting Repeaters
Frequency Shifting Repeaters
Frequency Shifting Repeaters
Device model RF-1822-D02T 18H02
RF-1822-R02T 18H02
Frequency Shifting Repeater(Broad)-MU(CSP3)
Frequency Shifting Repeater(Broad)-RU(CSP3)
Site ID 6 digits (normal character and
6 digits (normal character and
8 digits (Hex No.) 8 digits (Hex No.)
Comba FSR setting on OMC
© 2007 Comba Telecom, All Rights Reserved
normal No.) normal No.)
Site Sub ID 0 0 FF FF
Communication type
SMS SMS SMS SMS
Device Phone No. telephone No. of FSR repeater
telephone No. of FSR repeater
telephone No. of FSR repeater
telephone No. of FSR repeater
Device phone No. (Data)
telephone No. of FSR repeater
telephone No. of FSR repeater
telephone No. of FSR repeater
telephone No. of FSR repeater
OMC phone No. SMSC No. (94323) SMSC No. (94323) SMSC No. (94323) SMSC No. (94323)
Parameter type and FSR type
A1 master unit A1 remote unit A2 master unit A2 remote unit
SMS Center Number
+6691009120 +6691009120 +6691009120 +6691009120
Alarm Report Number
SMSC No. or OMC modem No.
SMSC No. or OMC modem No.
SMSC No. or OMC modem No.
SMSC No. or OMC modem No.
Site ID Same with OMC Same with OMC Same with OMC Same with OMC
Comba FSR setting on FSR repeater
Conclusion
Site ID Same with OMC Same with OMC Same with OMC Same with OMC
Site sub ID - - FF FF
Alarm report mode
SMS SMS SMS SMS
© 2007 Comba Telecom, All Rights Reserved
• in case of faulty FSR replacement , please confirm all parameter match between OMC side and FSR repeater side