combined noise tools · and gas movement. the audio sound from the tool through a surface module...

17
http://www.well-sun.com.cn XI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC Combined Noise Tools i Development i Innovation i Cooperation i Responsibility

Upload: others

Post on 26-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Combined Noise Tools

i Development

i Innovation

i Cooperation

i Responsibility

Page 2: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

A leaking well can damage the environment and result in production loss. The Noise Tool houses a

sensitive hydrophone that is highly effective in the detection of flow inside and outside the cased well. It

uses a piezoelectric sensor to detect downhole audio frequencies and amplitude variations due to fluid

and gas movement. The audio sound from the tool through a surface module allows the operator to

monitor well conditions.

The Noise Tool is combinable with Cement Bond Tool, Caliper Tool, Metal Thickness Tool, and etc. to offer

clients different service purposes.

h Locate Fluid or Gas entry points

h Channel identification

h Locate downhole mechanical problems

h Identify fluid contacts in well bore

h Identify active perforations

Overview

Application

Features & Benefits

h Digital spectrum and audio signal output

h Single trip logging with two or three noise tools for digital signal output to

decrease operation time

h Real-time spectrum noise analysis

h High resolution and sensitive measurement

h Memory/SRO configurations

h Combinable with any WSTbus tool

Technical Specification

h Max. Working Temperature:175℃(347℉)

h Max. Working Pressure:100MPa(14,500Psi)

h OD:43mm(1 11/16")/35mm(1 3/8")

Combined Noise Tools

Page 3: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

SROPanel from

Well-sun

Panel from

Warrior

Warrior AIP17 Warrior 8.0

CHT*

PSC21

HWT32

SCT35

SCT35

Unavailable

WTC38

GRT26

CCL38

With *GDT Protocol Developing

Auxiliary Tools

Optional

NST23*

Space Cartridge

NST24*

Combined Noise Tools

AIP 1U Acquisition Interface Panel

CHT Cable Head

CCL Casing Collar Locator

DRC Dual Roller Centralizer

DAS Data Acquisition System

GDT Global Dow nhole Tool Protocol Special for Warrior 8.0

GRT Gamma Ray Tool

HWT Heavy Weight Tool

HTU Head Tension Unit

NST Noise Spectrum Tool

PSC Sw ivel Sub

SRO Surface Readout

SCT Spring Bow Centralizer (Non-magnetic)

SHT Slickline Head

TDR Time-depth Recorder

WTC Wireline Telemetry Cartridge

* NST23 and NST24 are basically the same, but have different communication addresses.

* Cable Head for 5.6mm or 8.2mm Cable Optional

Page 4: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Specifications

Combined Noise Tools

482.6mm (19") × Width 413.0mm (16") × 44.45mm (1.75“)

Mounted in Standard 19” Frame

Weight 8Kg (18lb)

Operating Temperature (-10oC)- (+60oC)

AC100-240V(47-63Hz) or DC 140-343V

Applicable to international power supply

Max. Power 240 watt

Voltage DC25-240V, Adjustable

Adjustable Current 50-500mA, Power Less Than 100W

Continuous Working Time 48hrs

Transmissio Mono-conductor, Encode/Pulse Mode

Applicable Wireline Mono-/Multi-conductor

Depth Input Orthogonal Increment Signal, Output +5V power

Tension Input Analog with range 0.25V-5V, Output ±15V power

Port to PC USB

Depth Display Display(-9999.99)-(99999.99), Optional Metric/Imperial Unit.

Depth Sampling Interval 0-320m, Optional.

Drawing Scale 1:20 (50, 100, 200, 500, 1000) Optional

Max. Curves for Display 400

Max. Logging Speed 3200m/hr

Display Curve and Depth Synchronous Rolling

Record Hard Disk, Thermal Drawing

Dimensions

Operating Voltage

Power Supply

AIP17

Page 5: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Specifications

Combined Noise Tools

·DSP chip allowing adaptive processing of signal interface

· USB port for communication between the system and computer

· Chinese / English interface in software

· Outputs in multiple data formats

· Combinable with DDL Ⅲ (i.e. 5.8KBPS Manchester) Protocol tools

· Combinable with WSCbus protocol tools like MCT, EMT, CBL

· Combinable with WSCbus PLT tools

· Combinable with vertical focused magnetic thickness tool

· Combinable with gyro tool

· Combinable with Segmented Bonding Tool (SBT) in 3505 standard

· Combinable with neutron and C/O measuring tools

· Perforating operations conveyed in cable or tubing etc.

Specifications

AC Power Supply Voltage 110V/220V±11%

DC Power Supply Voltage 0-301V (continuous adjustable)

Power Rating 501W

Max Logging Depth 9001m

Max Logging Speed 3201m/h

Depth Sample Interval 0.00625/0.0125/0.025/0.05/0.2

Depth Display Range 0 ~ 9999.10m

Both curves and depth lines are

synchronously scrolled on screen

Plotting Medium Film and thermal paper

Max Numbers of Curves

Displayed101

Display Mode

Benefits

DAS23

Page 6: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Specifications

Combined Noise Tools

OD 1 11/16"

Start torque 0.14 N.m

Transmission Mono-conductor

PSC21

OD 1 11/16''

Cable Diameter 5.6mm and 8.2mm cable

Applicable Cable Size

CHT56 5.6mm cable

CHT58 8.2 mm cable

CHT

OD 1 11/16"

Weight 20kg

Transmission Mono-conductor

HWT32

OD 1 11/16"

Type Spring Bow Centralizer

OD After Opening 187mm(7.36")

Spring Bow Thickness: 1.2mm and 1.5mm(optional)

Applicable Range 2-7/8"-7"casing

Conductivity Insulation <0.5Ω

Insulation Resistance >5MΩ(Multimeter)

Material Non-magnetic

SCT35

Page 7: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Specifications

Combined Noise Tools

OD 1-11/16"

Measuring Mode Continuous /Stationary

Transducer Piezoelectric Ceramic

Frequency Range 100Hz-12.8KHz

Frequency Resolution 100Hz

Output Curve 128 logs

Audio Playing Available in MP3 format

NST16*

OD 1-11/16"

Measuring Mode Continuous /Stationary

Transducer Piezoelectric Ceramic

Frequency Range 100Hz-12.8KHz

Frequency Resolution 100Hz

Output Curve 128 logs

NST23*

OD 1-11/16"

Measuring Mode Continuous /Stationary

Transducer Piezoelectric Ceramic

Frequency Range 100Hz-12.8KHz

Frequency Resolution 100Hz

Output Curve 128 logs

NST24*

* NST23 and NST24 differ in communication addresses.

Page 8: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Specifications

Combined Noise Tools

OD 1 11 /16"

C C L SNR > 5

L o g g in g Sp e e d >400 m /h

CCL38

OD 1 11/16"

Measuring Range 0-10000 CPS

Sensor NaI

GRT26

Cable Mono-conductor

OD 1 11/16"

Operating Voltage

WTC38 180-200VDC

WTC45 200VDC

Operating Current

WTC38 24mA±10% (Zero-load)

WTC45 20mA±10% (Zero-load)

Max. Load Current

WTC38 1000mA

WTC45 2200mA

WSCBus Code AMI

WSCBus Uplink Rates 50, 71, 100, 143, 200Kbits

WSCBus Downlink Rate 300Kbits

WSCBus Uplink Amplitude ±14V

WSCBus Downlink Amplitude ±8V

WSTBus Code AMI

WSTBus Data Rate 500Kbits/sec

WSTBus Amplitude ±1V

WTC

Page 9: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Specifications

Combined Noise Tools

OD 1-11/16"

Le ngth 1524mm

We ight 15kg

Space

Cartridge

Page 10: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

Noise interpretation software analyses frequency spectrum, which

provides reference for production evaluation, leak detection and

channel location, etc.

Description

Interpretation Report

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Analysis

The stationary logging file shows strong noise around 2890m, and

full frequency range is displayed. This is not a perforated zone and

there is no special structure in the pipe column. Therefore, it is

identified as the leak point.

Result

The interpretation result clearly shows noise frequency spectrum

imaging at 2890m, where there should be the leak point.

Noise Case No. 1: Locating Fluid Loss from Producers

WTC

QPC

GRT

NST

RDT

Page 11: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

Interpretation Report

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Noise Case No. 1: Locating Fluid Loss from Producers

Page 12: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

Purpose of the logging is to know the injection into each zone in injection

profile.

Description

Interpretation Report

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Analysis

The stationary logging file shows low-frequency noise is absent from

1005m-1020m, while fairly strong mid-frequency noise is present.

Result

The interpretation result shows noise signals are clearly presented

between the two producing zones, and the frequency falls into that of

behind-casing noises. Therefore, there should be cementing issues ie.

channelling, between the zones.

Noise Case No. 2:

WTC

QPC

GRT

NST

RDT

Page 13: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

Interpretation Report

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Noise Case No. 2:

Page 14: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

Purpose of the logging is to know the packer effectiveness in injection profile.

Description

Interpretation Report

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Analysis

The stationary logging file shows there is fairly strong noise around 4543m,

where the packer has been deployed.

Result

The interpretation result shows very clear noise where the packer has been

deployed, which means the packer has a problem.

Noise Case No. 3: Packer Effectiveness Testing

WTC

QPC

GRT

NST

RDT

Page 15: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Noise Case No. 3: Packer Effectiveness Testing

Interpretation Report

Page 16: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

Purpose of the logging is to verify sand entry point and proportion in

production profile.

Description

Interpretation Report

Analysis

Based on stationary measurement documents, it is observed that there are

obvious noise wave above the depth 665m in this well.

Result

The interpretation result shows there is oil and sand entry above 670m,

and sand entry is serious at 600m and 422m.

Noise Case No. 4 – Dual Noise Logging

RDT

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

NST

NST

WTC

GRT

CCL

Page 17: Combined Noise Tools · and gas movement. The audio sound from the tool through a surface module allows the operator to monitor well conditions. The Noise Tool is combinable with

Noise Case No. 4 – Dual Noise Logging

http://www.well-sun.com.cnXI’AN WELL-SUN ELECTRONIC TECHNOLOGY PLC

Interpretation Report