C O M B I V E R T
F1 F2 F3 F4
ENTER ESC
GB INSTRUCTION MANUAL LCD operator
Mat.No. Rev.
PLF50EB-K000 1D
GB - 4
Table of Contents
1. Introduction ...................................................................................................61.1 General Information ........................................................................................61.2 Validity ............................................................................................................61.3 Qualification ....................................................................................................71.4 Order data .......................................................................................................71.5 Productdescription .........................................................................................8
2. Hardware .......................................................................................................92.1 Descriptionoftheoperator .............................................................................92.2 Internalflashmemory ...................................................................................112.3 Externalmemorycard ...................................................................................112.4 Systemfiles ..................................................................................................112.5 Technicaldata ...............................................................................................12
3. Software .......................................................................................................133.1 Main menu ....................................................................................................133.2 Operationofthefunctionkeys ......................................................................13
4 Inverter Parameters ....................................................................................154.1 Non-changeableparameters ........................................................................154.2 Changeableparameters ...............................................................................164.2.1 Changingwith„Up“and„Down“ ..................................................................................... 164.2.2 Setselection ...................................................................................................................174.2.3 Numericinput .................................................................................................................18
5. CP Mode ......................................................................................................19
6. Up/Download ...............................................................................................20
7. Work List .....................................................................................................21
8. Operator Parameters ..................................................................................22
9 Parameter Saving .......................................................................................23
10. File Operations ............................................................................................24
11. Settings ........................................................................................................2511.6 Backlight .......................................................................................................2611.7 Fileaccess ....................................................................................................2611.8 Softwareinformation .....................................................................................2611.9 Peakmemory ................................................................................................2611.10 Starttestmode .............................................................................................26
GB - 5
Table of Contents
12. Flash Functions ..........................................................................................27
13. Password Protection of the KEB COMBIVERT ........................................28
14. Error .............................................................................................................29
GB - 6
LCD Operator
1. Introduction
1.1 General InformationBeforeworkingwiththeunittheusermustbecomefamiliarwithit.Thisincludesespeciallytheknowledgeandobservanceofthesafetyandwarningdirections.Thepictographsusedinthisinstructionmanualhavefollowingmeaning:
Danger Indicatesdangertolifebyelectriccurrent.
Warning Indicatespossibledangertolifeordangerofinjury.
Note Indicatestipsandadditionalinformation.
1.2 ValidityThismanualaswellasthespecifiedhardwareandsoftwarearedevelopmentsoftheKarlE.BrinkmannGmbH.Errorsandomissionsexcepted!TheKarlE.BrinkmannGmbHhavepreparedthedocumentation,hardwareandsoftwaretothebestoftheirknowledge,however,noguaranteeisgiventhatthespecificationswillprovidetheefficiencyaimedatbytheuser.TheKarlE.BrinkmannGmbHreservestherighttochangethespecificationswithoutpriornotificationorfurtherobligation.Allrightsreserved.
Theinformationcontainedinthetechnicaldocumentation,aswellasanyuser-specificadviceinspokenandwrittenandthroughtests,aremadetobestofourknowledgeandinformationabouttheapplication.However,theyareconsideredforinformationonlywithoutresponsibi-lity.Thisalsoappliestoanyviolationofindustrialpropertyrightsofathird-party.
Inspectionofourunitsinviewoftheirsuitabilityfortheintendedusemustbedonegenerallybytheuser.Inspectionsareparticularlynecessary,ifchangesareexecuted,whichserveforthefurtherdevelopmentoradaptionofourproductstotheapplications(hardware,softwareordownloadlists).Inspectionsmustberepeatedcompletely,evenifonlypartsofhardware,softwareordownloadlistsaremodified.
GB - 7
LCD Operator
Inspection by theuser
Applicationanduseofourunits inthetargetproductsisoutsideofourcontrolandthereforeexclusivelyintheareaofresponsibilityoftheuser.
Use under specialconditions
TheusedsemiconductorsandcomponentsofKEBarede-velopedanddimensionedfortheuseinindustrialproducts.IftheKEBCOMBIVERTisusedinmachines,whichworkunderexceptionalconditionsorifessentialfunctions,life-supportingmeasuresoranextraordinarysafetystepmustbefulfilled,thenecessaryreliabilityandsecuritymustbeensuredbythemachinebuilder.
1.3 QualificationAllworkfromthetransport,toinstallationandstart-upaswellasmaintenancemayonlybedonebyqualifiedpersonnel(IEC364and/orCENELECHD384orDINVDE0100andnotenationalsafetyregulations).Accordingtothismanualqualifiedstaffmeansthosewhoareabletorecogniseandjudgethepossibledangersbasedontheirtechnicaltrainingandexperienceandthosewithknowledgeoftherelevantstandardsandwhoarefamiliarwiththefieldofpowertransmission(VDE0100,VDE0160(EN50178),VDE0113(EN60204)aswellasthosewhonotethevalidlocalregulations).
Dangerbyhighvoltage
KEBelectronic components contain dangerous voltages,whichcancausedeathorseriousinjury.Dependingontheprotectivesystem theycanhave liveparts,brightparts, ifnecessaryalsomovingparts,aswellashotsurfacesduringoperation.Careshouldbetakentoensurecorrectandsafeoperationtominimiserisktopersonnelandequipment.
1.4 Order dataOperatorgraphicLCD 00.F5.060-K000
OptionalfortheconnectionoftheLCDoperatortothediagnoseinterfaceofstandardoperators:
HSP5cablebetweenLCDandstandardoperators: 00.F5.0C0-0020
GB - 8
1.5 Product descriptionTheLCDoperatorhasadisplaywithatextindicator,whichenablesaclearlyrepresenta-tionofcomprehensiveinformations,forexampleaparameternamewithitsvalue.Severallanguagesareavailable.Thefour functionkeysareoccupiedvariable. Internalandexternalpossibilityofsavingenablesthetransmissionandstorageofparameterlistsandtherebyafasterprogrammingof inverter.
Thisinstructionmanualdescribesthesoftwarestatusstartingfrom2009-12-08.
GB - 9
Hardware
2. Hardware
2.1 Description of the operator
F1 F2 F3 F4
ENTER ESC
(1) Lockarm
(2) LCDdisplay160x160pixel,32grayscalevalue
(3) Functionbar
(4) FunctionkeysF1toF4
(5) Up
(6) ESC
(7) Down
(8) ENTER
1 Theoperatorcanberemovedfromtheinverter.
2 TheLCDdisplayoffersadetailed representationof the informationwithaplaintextdisplay.
3 Aflashingfunctionbarindicatesaninvertererror.
4 ThefunctionkeysF1toF4arevariableassigned.Theassignmentisdisplayedbythefunctionbar.
5 and 7 With"Up"and"Down"itcanbemovedbetweenthemenuitemsorchangingpa-rametervalues.
6 WithESCajumptothenextsuperiormenuisdone.
8 WithENTERitcanbejumpedintotheselectedmenuitemoraselectioncanbeconfirmed.
GB - 10
1 GND Voltagesupply
2 RxD Receivesignal,0-active
3 TxD Transmissionsignal,0-active
4 VCC Voltagesupply+,connectedwith9
5 GND Referenceforsignals
6 GND connectwith5
7 E_TxD transmithandshakesignal,1-active
8 E_RxD receivehandshakesignal,1-active
9 VCC Voltagesupply+,connectedwith4
Hardware
X6A:SUB-D9femaleHSP5interface
1 2 3 4 5
6 7 8 9
GB - 11
AninstalledcardshaftatthebottomsideservesforinputofSDorMMCmemorycards
Hardware
2.2 Internalflashmemory AccesstothismemoryispossibleviadeviceC:.Systemfiles,workandparameterlistsarestoredhere.Observethefollowingparticularities:
● Longfilenamesupto32charactersarepossible.
● Dataarenotphysicallydeleted.Atfirsttheyareinternalmarkedasdeleted.Thustheavailablememorycapacitydecreases.Thecompletememoryisformattednewwiththecommand"format".Alldataareirrevocabledeleted.
● With thecommand"clear" thedeletedmemorycapacitycanbemadeavailableagainwithoutreformatting.
IftheFlashmemoryisformattedduringafirmwareupdate,sothefilesLANGU-AGE.DATandPARAS.BLBmustbecopiedfromtheSDcard.
2.3 External memory card ASDorMMCmemorycardofanycapacitycanbeinsertintotheslotoftheoperating
unit.AccesstothismemoryispossibleviadeviceA:.Anyfilescanbestoredalsohere.Observethefollowingparticularities:
● ThefilesystemisFAT16andFAT32andthuscompatiblytoexternalreadersandWindowsoperatingsystems.
● Itcanbeaccessedonlytofilesinthemaindirectory.
● Longfilenames(upto32characters)arepossible.
● Thewriteprotectionswitch (atSDcards) isconsidered,writingon thecardonlypossibleafterrelease.
2.4 SystemfilesNecessarysystemfiles:
● LANGUAGE.DAT: Textsinalllanguagesfortheoperationoftheoperator
● PARAS.BLB: Parameterfunctionsandnamesforallinverterandoperatorparameters
GB - 12
2.5 Technical data
GeneralDimension(HxBxT) 160 x 75 x 30Weight 160gProtectivesystem(EN60529) IP20Operation temperature -10°…45°CStoragetemperature -25°…70°CClimaticcategory(EN60721-3-3) 3 K 3Environment(IEC664-1) Pollutiondegree2Flashmemory 4MBytes
External memory SDorMMCmemorycardsofanycapacity
GB - 13
Software
3. Software
3.1 Main menu
F1 F2 F3 F4
Inverter parameterCP modeUp/DownloadWorklistOperator parameterParametersavingFileoperationsSetupFlashfunctions
ENTERJumpintothesubmenu
→
←Returntothemainmenu
F1
The function keysF1 to F4 can be assigned as follows depending on the respectivesubmenu.
3.2 Operation of the function keysDisplay Function
Flash/Card Changebetween internalflashmemoryandexternalmemorycard
DecHex Changebetweendecimalandhexadecimaldisplay
Num Numericinput:manualinputofnumbers
Set Changingthesets[Ι],[A]or[0-7]
Select Selectionofaconfigurationfile
Last Selectthelastusedconfigurationfile
Top/Bottom Changebetweenfirstandlastlistitem
Formt 1)
The completememory including the system file isformattedagain.→Dataareirrevocabledeleted
CinUp 1) Makedeletedmemoryspacewithoutnewformattingavailableagain
Delete 1) Deletetheselectedfileofmemorycardorflashmemory
Upload Loadcompletedownloadlistfromcurrentinverter
furtheronnextside
GB - 14
Software
Display Function
Download Storedownloadlistintheinverter
Copy Copyoffilesbetweenflashmemoryandmemorycard
←→ Movetotheleftandright(e.g.atnumericinputorinputoffilenames)
CList Acompleteparameterlistisgenerated
Menu Returntothemainmenu
Yes Processconfirm
+- Thesignischanged
, Apointandafurtherdigitareinserted.
1) Fileaccessispossibledependingonthepasswordlevel,reducedorswitchedoff
GB - 15
4 Inverter Parameters
4.1 Non-changeable parameters
Inverter Parameters
Theparametergroupsaredependingontheinverter
F4F1 F2 F3
MenuCListTopBottom
ru run parameteroP operational parameterPnprotectionparametercScontrolspeedparameterdSdrivespec.controlparauFu/fparameterdr drive parametercncontrolparameterEcencoderparameterUduserdefinitionpara.Frfreeprogrammablepara. ▼
F1 F2 F3 F4
Top Bottom
ru00inverterstate[]66forwardconstantru01setvaluedisplay[]153.0001/minru02rampoutputdisplay[]153.0001/minru03actualfrequencydisplay[]15.3000Hzru09encoder1speed[]0.0001/minru10encoder2speed ▼
ENTER
→
←
ESC
ENTER
ESC
F1 F2 F3 F4
DecHex
ru000200hinverterstate
66
inverterstateforwardconstant
Withnon-changeableparameters:
OnlyESCpossible!→Parameternon-changeable!
→
↓ ENTER
Changeableparameterssee4.2
GB - 16
Inverter Parameter
4.2 Changeable parameters
4.2.1 Changing with „Up“ and „Down“
F1 F2 F3 F4
Set Top Bottom
oP02rotationsetting ▲[I]0:lowspeedoP03referencesetting[I]0.0001/minoP05referencesetting%[I]0.0%oP06min.referenceforward[I]0.0001/minoP07min.referencereverse[I]-1:=forwardparameteroP10max.referenceforward▼
Set selectionsee4.2.2
F2
←
ESC ↑↓ ENTER
F1 F2 F3 F4
DecHex
oP060306hSet:Imin.referenceforward
0.000 1/min
Store parameter value
ESC ↑↓ ENTER↑ ENTER
F1 F2 F3 F4
DecHexNum
oP060306hSet:Imin.referenceforward
0.0001/minNumericinputsee4.2.3 Increaseordecrease
parametervaluewith„Up“and„Down“
F4→←
GB - 17
Inverter Parameter
4.2.2 Set selection
Indirectset-programming
F1 F2 F3 F4
Set Top Bottom
oP02rotationsetting ▲[I]0:lowspeedoP03referencesetting[I]0.0001/minoP05referencesetting%[I]0.0%oP06min.referenceforward[I]0.0001/minoP07min.referencereverse[I]-1:=forwardparameteroP10max.referenceforward▼
↓ F2
Directset-programming
F1 F2 F3 F4
Set Top Bottom
oP06min.referenceforward▲[0]0.0001/min[1]233.0001/min[2]233.0001/min[3]233.0001/min[4]233.0001/min[5]233.0001/min[6]0.0001/min[7]0.0001/minoP07min.referencereverse[I]-1:=forwardparameter ▼
F2
↓ F2
Currentset
F1 F2 F3 F4
Set Top Bottom
oP06min.referenceforward▲[A]0.0001/minoP07min.referencereverse[I]-1:=forwardparameteroP10max.referenceforward[I]700.0001/minoP11max.referencereverse[I]-1:=forwardparameteroP14abs.max.referencefor[I]4000.0001/minoP15abs.max.referencerev▼
GB - 18
Inverter Parameter
4.2.3 Numeric input
F1 F2 F3 F4
DecHexNum
oP060306hSet:Imin.referenceforward
0.0001/min
F4
F1 F2 F3 F4
+-<-,>>
oP060306hSet:Imin.referenceforward
01/min
→
←
ESC
←
ENTER
Round up to the next va-lid value and write to theunit
F1 F2 F3 F4
Thesignischan-ged
Adigitisremoved Apointandafurtherdigitareinserted.Thedigitcanbechangedwith"UP"and„Down“.
Withseveralpointsonlythefirstisconsidered!
Thedisplayisextendedbyadigit.Thedigitcanbechangedwith"UP"and„Down“.
GB - 19
CP Mode
5. CP Mode
F1 F2 F3 F4
CP00password[0] application passwordCP01LDvoltage[0-7] 375 VCP02softwareversion[0] 2.60CP03softwaredate[0] 501.3
▼
Menu Top Bottom
CP mode
Thedefinedcustomerparametersintheinverteraredisplayed.Operationtakesplaceliketheinverterparameters.
The representationsizeof theparametervaluescanbeadjustedsepa-rately!→see“menu“→“adjustments“→“typesize2“
GB - 20
F1 F2 F3 F4
DWN1541.DW5 F5C.dw5F5CAA.DW5 F5C_.DW5 F5G_.DW5
MenuFlashUploadDownload
F1 F2
Back to themain menu
CardThefilepathisonmemorycardandchangestoflash
FlashThefilepathisonflashandchangestomemorycard
F3 Generate-correctionisrequired F4
Adownloadlist is loaded from the current inverter andstoredundernewname
A downloadlist is stored in theinverter
↓ENTER ↓ESC ↓ENTER ↓ESC
F1 F2 F3 F4
F5C.dw5F5C_.DW5
<->>
Newfilename:F5C_
ENTER:okESC:Cancel
Cancel processconfirmed Cancel
↓ ↓
A digit isremoved
Adigitisadded.Thedigitcanbechangedwith"UP"and„Down“:0-9; _ ; A-Z
↓ENTER ↓ESCAcompleteparameter list canbegeneratedwith"CList"inthemenuitem"inverterparameter".
Procedure confir-med/if necessary"overwrite“inquiry
Cancel
ENTER
Displayoffilename/size/date/time.Sincethereisnoreal-timeclockintegratedintheLCDoperator,newcreatedfileshavethedate01.01.2003.
Up/Download
6. Up/Download
GB - 21
Work List
7. Work List
F1 F2 F3 F4
F5.wr5
MenuFlash
ENTER
Displaysof thework listF5.wr5
→
←
ESC
Theselectionofaworklistofthememorycardortheflashmemory(functionkeyF2)occursinthismenuitem.
ThecompilationoftheworklistmustbedonewithCOMBIVIS.
GB - 22
Operator Parameters
8. Operator Parameters
TheLCDoperatormustbeconnectedtotheHSP5diagnosticinterfaceoftheappropriateoperatorforrepresentationofoperatorparameters.
Theoperatorcan load theappropriateparameters ifavalidconfigurationnumber isrecognized.Operationtakesplaceliketheinverterparameters.
F1 F2 F3 F4
Parameters for the ope-rator
Top Bottom
EitheraconfigurationfilecanbeselectedviafunctionkeyF2orthelastusedconfigurationfilecanbetakenviafunctionkeyF4ifnoconfigurationnumberisrecognized.
F1 F2 F3 F4
Estimatedeviceconfiguration…
SelectLast
Operator parameternotpresent
GB - 23
Parameter Saving
9 Parameter Saving
F1 F2 F3 F4
Saveparameters(Upload)=F3
Writeparameters(Download)=F4
ChangeDrive(Flash/Card)=F2
MenuCardUploadDownload
F3 F4
All inverter and operator parameters (if anoperatorisavailable)arereadoutandsavedin the flashmemory ormemory card.Everynewuploadprocessoverwritesthepre-savedparameterlists.
A download is not possible withoutsaved inverter parameters→ errormessage!
Operator parameters areonlywritteniftheyaresavedintheflashmemoryormemory card and if an operatorison thenew inverter,which is tobewritten.
Fixedfilenamesforsavedparameterlists:
Inverterparameters: %%SAVEFU.DW5
Operatorparameters: %%SAVEOP.DW5
GB - 24
File Operations
10. File Operations
F1 F2 F3 F4
File lists on the Flashmemory
MenuFlashCopyDelete
F2 F3 F4 ENTER
Changebetweenthefiles of thememorycardand thefilesoftheflashmemory.
The selected fi leis copied betweenflashmemory andmemory card. Thegenerate-correctionisrequired.Ifthetargetfileisal-readyavailable,alsothedelete-authoriza-tionisnecessary.
Theselectedfileofthe memory cardor theflashmemo-ry is deleted. Thedelete-authorizationisnecessary.
Displayoffilename/size/date/time.Since there is noreal-time clock in-tegratedintheLCDoperator,newcre-atedfileshavethedate 2003-01-01.
Anautomatic "clearing" isdone ifnotenoughmemory isavailableduringcopyingfilestotheflashmemory(seechapt.2.2).
GB - 25
Settings
11. Settings
F1 F2 F3 F4
Language EnglishStartup mode MenuFontsize 13Fontsize2 24Contrast 24Backlight OnFileaccess Off0SF5AK01000 Jan 9 2008PeakMemory 67%59%StarttestmodeMenu
Tostorechangesnon-volatile,a return to themainmenu is requiredwiththeF1key.
11.1 LanguageAlanguageisselectedforthemenuandtheparameters.IftheselectedlanguageisnotavailabletheparametersaredisplayedinEnglish.
11.2 Startup modeThestartupmodedeterminesthemenuitemafterinitializationoftheoperator.
11.3 FontsizeItcanbeselectedbetweenfontsizes8.10.13.16and24inthedisplay.Exception:see„fontsize2“
11.4 Fontsize2ThefontsizeforthedisplayofparametervaluesisspecifiedintheCPmodeandintheworklist.
11.5 ContrastThecontrastadjustmentsoftheLCDdisplaycanbechangedwithintherangeof0to50.
GB - 26
Settings
11.6 BacklightIfthebacklightdisplays„on"itisgenerallyswitchedon.Ifthebacklightisadjustedto"out"it isgenerallyswitchedoff.Ifthebacklight isadjustedto"auto", it isswitchedonduringpressingakeyandswitchedoffagainafter10secondsifnokeyispressed.
11.7 File accessThefollowingpossibilitiesareavailabletodeterminethefileaccess:
Display Function Password
Off Filescannotbegeneratedordeleted 0
Create Filescanbegenerated 55
Create/Delete Existing files can be generated, deleted or over-written 345
11.8 Software informationThedisplayindicatesthematerialnumberandtheoutputdataoftheoperatorsoftware.
11.9 Peak memoryThepeakloadofthetextmemoryisdisplayedfirst.Thepeakloadvalueofthecommuni-cationbufferisdisplayedbehind(thisdisplayisonlyforinformation).
11.10 Start test modeThismodeteststhekeyboardandthedisplay.Followtheinstructionsofthedisplay.
GB - 27
Flash Functions
12. Flash Functions
F1 F2 F3 F4
Informations about theinternalflashmemory
Menu Formt ClnUp
F3 Generate-/delete-authorizationisrequired
F4
Thecompletememoryincludingthe system files is formattedagain.→Dataareirrevocabledeleted!
The deletedmemory capacity can bemade available again without refor-matting.
GB - 28
Start-Up
13. Password Protection of the KEB COMBIVERT
TheKEBCOMBIVERTisequippedwithanextensivepasswordprotection.ThisaffectstheLCDoperatorasfollows:
Passwordlevel Meaning LCD operator
CP read Reading isonlypossible in thefinalcustomermenu(CP-Parameter).
No inverter para-metersNo operator para-meters
CP-read/ write
Readingandwritingispossibleinthefinalcu-stomermenu(CP-Parameter)
Applicationmode
All parameter groups and parameters arevisible
Norestriction
Thechangebetweenthepasswordinputs:
Currentpasswordlevel Passwordinputinparameter
CP mode CP.00
Applicationmode Ud.01
GB - 29
Error
14. Error
● Error: Passwordsettinginsufficient
Cause: Selectionofparametersatlowpasswordlevel
Solution: AdjustanotherpasswordintheCPmode
● Error: Thefollowingmessageisdisplayedwhenswitchingon:
F1 F2 F3 F4
Configuration320notavailableSELECTIONadjuststheunit type manuallyLASTuseslasttype1572ESCaborts
SelectLast
Solution: ● SelectthelastusedparameterconfigurationwiththefunctionLAST
● SelectanewparameterconfigurationwiththefunctionSELECTION
● Loadthecurrentsystemfile"PARAS.BLB"fromtheinternettothememorycardanddownloadittotheoperatorflashmemoryinthemenuitem"filemanagement"
● Error: Theparametersarenotdisplayedintheselectedlanguage
Solution: Loadthecurrentsystemfile„PARAS.BLB“fromtheinternettothememorycardanddownloadittotheoperatorflashmemoryinthemenuitem"filemanagement"→eventuallynotallparametersareavailablehereinthedesiredlanguage
KEB Antriebstechnik Austria GmbHRitzstraße8•A-4614Marchtrenk
fon:+43724353586-0•fax:+43724353586-21net:www.keb.at•mail:[email protected]
KEB AntriebstechnikHerenveld2•B-9500Geraadsbergen
fon:+3254437860•fax:+3254437898mail:[email protected]
KEB Power Transmission Technology (Shanghai) Co.,Ltd.No.435QianPuRoad,SongjiangEastIndustrialZone,
CHN-201611Shanghai,P.R.Chinafon:+862137746688•fax:+862137746600
net:www.keb.cn•mail:[email protected]
KEB Antriebstechnik Austria GmbHOrganizačnísložka
K.Weise1675/5•CZ-37004ČeskéBudějovicefon:+420387699111•fax:+420387699119net:www.keb.cz•mail:[email protected]
KEB Antriebstechnik GmbHWildbacherStr.5•D–08289Schneebergfon:+49377267-0•fax:+49377267-281
mail:[email protected]
KEB EspañaC/Mitjer,Nave8-Pol.Ind.LAMASIA
E-08798SantCugatSesgarrigues(Barcelona)fon:+34938970268•fax:+34938992035
mail:[email protected]
Société Française KEBZ.I.delaCroixSt.Nicolas•14,rueGustaveEiffel
F-94510 LA QUEUE EN BRIEfon:+33149620101•fax:+33145767495
net:www.keb.fr•mail:[email protected]
KEB (UK) Ltd.6ChieftainBuisinessPark,MorrisClose
ParkFarm,WellingboroughGB-Northants,NN86XFfon:+441933402220•fax:+441933400724
net:www.keb-uk.co.uk•mail:[email protected]
KEB Italia S.r.l.ViaNewton,2•I-20019SettimoMilanese(Milano)fon:+390233535311•fax:+390233500790
net:www.keb.it•mail:[email protected]
KEB Japan Ltd.15–16,2–Chome,TakanawaMinato-ku
J–Tokyo108-0074fon:+8133445-8515•fax:+8133445-8215
mail:[email protected]
KEB Korea SeoulRoom1709,415Missy2000
725SuSeoDong,GangNamGuROK-135-757Seoul/SouthKorea
fon:+82262536771•fax:+82262536770mail:[email protected]
KEB RUS Ltd.LesnayaStr.House30,Dzerzhinsky(MO)
RUS-140091Moscowregionfon:+74955508367•fax:+74956320217
net:www.keb.ru •mail:[email protected]
KEB SverigeBox265(Bergavägen19)
S-43093Hälsöfon:+4631961520•fax:+4631961124
mail:[email protected]
KEB America, Inc.5100ValleyIndustrialBlvd.South
USA-Shakopee,MN55379fon:+1952224-1400•fax:+1952224-1499
net:www.kebamerica.com•mail:[email protected]
© KEBMat.No. PLF50EB-K000
Rev. 1DDate 02/2010
More and newest addresses at http://www.keb.de
Karl E. Brinkmann GmbHFörsterweg36-38•D-32683Barntrup
fon:+495263401-0•fax:+495263401-116net:www.keb.de•mail:[email protected]
KEB worldwide…