comments to the study on the pipe-to-soil voltages induced in the czech oil pipelines

6
ESWW4 5-9 Nov 20 07 GETG Splinter Meting Pipe to soil voltages 1 Comments to the study on Comments to the study on the pipe-to-soil voltages the pipe-to-soil voltages induced in the Czech oil induced in the Czech oil pipelines pipelines (Issues behind science) (Issues behind science) Pavel Hejda Institute of Geophysics of the ASCR, Prague, Czech Republic

Upload: quincy-boyd

Post on 30-Dec-2015

22 views

Category:

Documents


0 download

DESCRIPTION

Comments to the study on the pipe-to-soil voltages induced in the Czech oil pipelines (Issues behind science). Pavel Hejda Institute of Geophysics of the ASCR, Prague, Czech Republic. Oil pipelines in the Czech Republic. Owner of the Czech pipelines is the company MERO ČR a.s . - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Comments to the study on the pipe-to-soil voltages induced in the Czech oil pipelines

ESWW4 5-9 Nov 2007 GETG Splinter Meting

Pipe to soil voltages 1

Comments to the study on the Comments to the study on the

pipe-to-soil voltages induced in pipe-to-soil voltages induced in

the Czech oil pipelinesthe Czech oil pipelines

(Issues behind science)(Issues behind science)

Pavel Hejda

Institute of Geophysics of the ASCR, Prague, Czech Republic

Page 2: Comments to the study on the pipe-to-soil voltages induced in the Czech oil pipelines

ESWW4 5-9 Nov 2007 GETG Splinter Meting

Pipe to soil voltages 2

Oil pipelines in the Czech Republic

Owner of the Czech pipelines is the company MERO ČR a.s.

The monitoring of cathodic protection is provided by service company 1.korozni, spol. s r.o.

MERO ČR operates two pipeline systems: Družba built in sixties and seventies and IKL (Ingolstadt – Kralupy) built in the beginning

of nineties.

Page 3: Comments to the study on the pipe-to-soil voltages induced in the Czech oil pipelines

ESWW4 5-9 Nov 2007 GETG Splinter Meting

Pipe to soil voltages 3

Data

We have obtained data registered at (remote control) stations for monitoring of cathodic protection (distant from cathodic protection stations)

• 63 stations distributed over the entire network • sampling rate: 30 seconds or 1 minute• time interval: autumn 2004 – spring 2005

However, technicians of the company were stingy about technical details. They were also afraid of leaking of information.

Page 4: Comments to the study on the pipe-to-soil voltages induced in the Czech oil pipelines

ESWW4 5-9 Nov 2007 GETG Splinter Meting

Pipe to soil voltages 4

Preliminary results: Correlation between pipe-to-soil voltages and geoelectric field computed from geomagnetic observatory data -

November 6 to 11, 2004

As the induced pipe-to-soil voltage depends not only on the magnitude of the electric field but also on its direction, we computed a direction which gives the highest correlation.

The size of the arrows is proportional to the correlation coefficient (maximum is 0.88) and the angle shows the best fit direction.

Electrified railways – DC supplied and AC supplied

Page 5: Comments to the study on the pipe-to-soil voltages induced in the Czech oil pipelines

ESWW4 5-9 Nov 2007 GETG Splinter Meting

Pipe to soil voltages 5

Geomagnetically induced pipe-to-soil voltages - problems

7-Nov-04 8-Nov-04 9-Nov-04

-1 .8

-1 .6

-1 .4

-1 .2

-1

-0 .8

-0 .6

Pto

S v

olta

ge (

V)

14-04O rechov

-300

-200

-100

0

100

200

Com

pute

d E

(m

V/k

m)

7-Nov-04 8-Nov-04 9-Nov-04

-2

-1 .6

-1 .2

-0 .8

-0 .4

0

Pto

S v

olta

ge (

V)

15-00V_B ites

-200

-100

0

100

200

300

Com

pute

d E

(m

V/k

m)

7-Nov-04 8-Nov-04 9-Nov-04

-4

-3

-2

-1

0

1

Pto

S v

olta

ge (

V)

I28Katerina

-200

-100

0

100

200

300

Com

pute

d E

(m

V/k

m)

7-Nov-04 8-Nov-04 9-Nov-04

-2 .4

-2 .2

-2

-1 .8

-1 .6

-1 .4

Pto

S v

olta

ge (

V)

I32Vrbice

-300

-200

-100

0

100

200

Com

pute

d E

(m

V/k

m)

The best-fit directions confirm the prevailing influence of component of electric field parallel to the pipe-line, but only in Druzba pipeline!

Changes in orientation: do they corresponds to the standing waves in transmission line?

The effect of cathodic protection?

Page 6: Comments to the study on the pipe-to-soil voltages induced in the Czech oil pipelines

ESWW4 5-9 Nov 2007 GETG Splinter Meting

Pipe to soil voltages 6

Can we get more?

Boteler (1991) has shown that the telluric voltage induced in the pipeline can be calculated using distributed source transmission line (DSTL) theory.

However:

• the pipelines are divided into segments (10 – 20 km) by ferro-concrete shafts

• there is always a bundle of pipelines (oil, gas, ..)

• the long-distance pipelines are crossed by many local (gas) pipelines