Page 1: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER
Page 2: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

• Working Party• Meeting 2013 and 2014• Australasian Involvement• Publications in Pipeline• Paediatric WP• Pregnant Ranges Evaluated• Recommendations for action

Page 3: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

• Results to Date• Tests added to List• Action by Laboratories• Battachyria analysis• Data extraction analysis• Median of Values obtained• Calculated Ranges

Page 4: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

• Survey results• Bias Assessment• Battacharyia• Aussie Normals• Manufacturers RI• Calculated Results Survey• Back to basics check

Page 5: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

0.0%

5.0%

10.0%

15.0%

20.0%

25.0%

30.0%

35.0%

4.8 4.9 5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7

Upper reference interval for Potassium mmol/L

4.8

4.9

5.0

5.1

5.2

5.3

5.4

5.5

5.6

5.7

Page 6: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

3.8

3.9

4

4.1

4.2

4.3

4.4

4.5

4.6

4.7

4.8

4.9

5

5.1

5.2

5.3

5.4

3.8 3.9 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5 5.1 5.2 5.3 5.4

ADVIA 2400 Architect AU2700 DxCIntegra Modular RxL VitrosLinear (ADVIA 2400) Linear (Architect) Linear (AU2700) Linear (DxC)Linear (Integra) Linear (Modular ) Linear (RxL) Linear (Vitros)

Page 7: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

Potassium Variation

• Instrument Variation

• Pre Analytical Variables

• ISE Technology

• Precision of Assay

Page 8: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

ISE Nernst Equation

• Use of common equation

• Differences due to electrode factors

• Variations minimal

• CV 1-2% obtained

Page 9: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

0.0%

10.0%

20.0%

30.0%

40.0%

50.0%

60.0%

70.0%

95 100 105 110 115 120 125

Upper reference interval for Creatinine umol/L Male

95

100

105

110

115

120

125

Page 10: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

4048566472808896

104112120128136144152

40 48 56 64 72 80 88 96 104 112 120 128 136 144 152

Alan

lytic

al p

altfo

rm a

vera

ge c

once

ntra

tion

Average

Creatinine

ADVIA 2400 Architect AU2700 DxCIntegra Modular RxL VitrosLinear (ADVIA 2400) Linear (AU2700) Linear (DxC) Linear (Integra)Linear (Modular ) Linear (RxL) Linear (Vitros)

Page 11: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

Creatinine Standardisation

• Equation for eGFR – CKD - EPI• Standardisation of all methods• Various intercepts in place – method

dependent or are they?• Review of manufacturers calculation

parameters

Page 12: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

0.0%

5.0%

10.0%

15.0%

20.0%

25.0%

30.0%

35.0%

40.0%

40 45 50 55 60 65

Upper reference interval for GGT

40

45

50

55

60

65

Page 13: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

• Manufacturer Decision• Allowable Limits of Performance – Calibrator• Allowable limits for Performance – Extinction

Coefficients• Commonality of Calculation Factors• Method Variations

Page 14: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

Enzyme Calculation

• Manufacturer Dependent

• Calibration from Extinction Coefficient

• Calibration from Prepared Calibrator

• Dry Chemistry Estimation

Page 15: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

0

5

10

15

20

25

30

35

40

45

50

55

0 5 10 15 20 25 30 35 40 45 50 55

ADVIA 2400 Architect AU2700 DxCIntegra Modular RxL VitrosLinear (ADVIA 2400) Linear (Architect) Linear (AU2700) Linear (DxC)Linear (Integra) Linear (Modular ) Linear (RxL) Linear (Vitros)

Page 16: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

Enzyme Kinetics

• 1St Order Reaction• Zero Order Reaction• Initial Velocity Reaction• Km Values• Inhibitors – Competitive, Non Competitive and

Uncompetitive

Page 17: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

Colorimetric Reactions

• Optimisation of Chemistries• Wavelength Selection• Reaction reading times• Calibrator values• Calculation from data obtained

Page 18: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER
Page 19: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

Reaction Traces

• End point reactions

• Rate Reactions

• Similarity between Manufacturers

• Choice of slope parameters

Page 20: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

• Abbott Diagnostics Architect• Roche Diagnostics Modular• Roche Diagnostics Integra• Beckman Coulter DxC• Beckman Coulter Olympus• Siemens Healthcare Dimension• Siemens Healthcare Advia• Ortho Clinical Diagnostics Vitros.

Page 21: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

0.0

5.0

10.0

15.0

20.0

25.0

30.0

0 5 10 15 20 25 30

Iron

Obt

aine

d

Iron Average

Iron

ADVIA2400Architect

AU2700

DxC

Page 22: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

5.0

10.0

15.0

20.0

25.0

30.0

5 10 15 20 25 30

Iron

Obt

aine

d

Iron Average

Iron

ADVIA 2400ArchitectAU2700DxCModularVitros

Page 23: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

• Decision ? Implement LDH L-P, ALT, Urate.

• Platform Suitability

• Manufacturer Involvement – LDH (L-P)

Page 24: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

• Involve Manufacturers

• Obtain Calculated Values for Comparison

• Comparisons with Population results

• Implement Standardised Calculation values

Page 25: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER

• Gus Koerbin• Ken Sikaris• Graeme Jones• Maxine Reed• George Koumentakis• Jill Tate• Jan Gill• All who have participated in the 2013 Symposium• All involved with the Harmonisation Initiative

Page 26: COMMON REFERENCE INTERVALS ADDITION OR TAKEOVER