87-SEAL-SHIELD (877-325-7443) | [email protected] SealShield.com COMPLETE PRODUCT CLEANING GUIDE Washable & Waterproof Keyboards and Mice, Medical-Grade Screen Protectors, and ElectroClave UV-C Disinfection System Guidelines For The Safe & Effective Disinfection Of: The ElectroClave is 99.9% effective against: Staphylococcus, E. coli, MRSA and CRE on hard, non-porous surfaces.

Upload: others

Post on 15-Oct-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: COMPLETE PRODUCT CLEANING GUIDE - Seal Shield

87-SEAL-SHIELD (877-325-7443) | [email protected] SealShield.com

COMPLETE PRODUCT

CLEANING GUIDE

Washable & Waterproof Keyboards and Mice, Medical-Grade Screen Protectors, and ElectroClave UV-C Disinfection System

Guidelines For The Safe & Effective Disinfection Of:

The ElectroClave is 99.9% effective against: Staphylococcus, E. coli, MRSA and CRE on hard, non-porous surfaces.

Page 2: COMPLETE PRODUCT CLEANING GUIDE - Seal Shield

87-SEAL-SHIELD (877-325-7443) | [email protected] SealShield.com

CLEANING GUIDE

Apple iPad are trademarks of Apple, Inc., registered in the U.S. and other countries.

Copyright© 2016, Seal Shield, LLC. All rights reserved. All other trademarks and trade names are those of their respective owners.

PRODUCTS COVEREDIN THIS GUIDE

KEYBOARDS MICE

SCREEN PROTECTORSELECTROCLAVE UV-C DISINFECTION

• Seal Shield Seal Glow Waterproof Keyboards

• Seal Shield Seal Touch Waterproof Keyboards

• Seal Shield Seal Flex Waterproof Keyboards

• Seal Shield Clean Wipe Waterproof Keyboards

• Seal Shield Clean Seal Waterproof Keyboards

• Seal Shield Clean Storm Waterproof Keyboards

• Seal Shield Clean Surf Waterproof Mice

• Clean Shield Medical-Grade Mice

• Seal Shield Waterproof Mice

• Seal Shield Clean Storm Waterproof Mice

• Seal Shield Seal Screen Medical-Grade Screen Protectors

• Seal Shield Medical-Grade Screen Protectors

• 2-Bay ElectroClave

• 3-Bay ElectroClave

• 4-Bay ElectroClave

Following advanced, evidence-based infection prevention & cleaning practices can improve hand

hygiene, greatly reduce the number of HAIs (hospital aquired infections), and provide better overall

safety for both employees and guests in any work environment. Seal ShieldTM washable & waterproof

keboards & mice and multilayer screen protectors are purposefully designed to withstand regular &

vigorous cleaning and are compatible with medical-grade disinfectants & cleaners for

effective sanitation within all healthcare and other settings.

1

Page 3: COMPLETE PRODUCT CLEANING GUIDE - Seal Shield

orem ipsum

87-SEAL-SHIELD (877-325-7443) | [email protected] SealShield.com

CLEANING GUIDE

TABLE OF

3

C O N T E N T S

5

Disinfection Instructions forWashable & Waterproof Keyboardsand Mice

4Installation & Disinfection Instructions for MultiLayer Screen Protectors

Instructions for Disinfecting MobileDevices using ElectroClave

Instructions for Disinfecting the ElectroClave UV-C Disinfection System

2

Page 4: COMPLETE PRODUCT CLEANING GUIDE - Seal Shield

87-SEAL-SHIELD (877-325-7443) | [email protected] SealShield.com

CLEANING GUIDEKEYBOARDS | MICE

D I S I N F E C T I O N I N S T R U C T I O N SSEAL SHIELDTM KEYBOARD & MICE PRODUCTS

Prior to rinsing or submering in water, ensure Seal Caps TM are connected tighly over any USB cables. For the following products (SSKSV207RUSA, SSKSV099, SSKSV099BT, SSWKSV099, SSWKSV099BT) ensure Seal Plugs™are inserted properly into keyboard. Following these procedures maintains the product’s performance.

STEP

1.Choose a compatible disinfectant from thetable below

STEP

2.Follow the “Instructionsfor Use” from the selecteddisinfection manufacturer

STEP

3.Liberally rinse the productwith water to remove any disinfectant residue

KE

YB

OA

RD

SM

ICE

Bleach1Chlorhexidine

Gluconate

Hydrogen

Peroxide2

Quaternary

Ammonium

Chloride

Isopropyl

Alcohol3

StandardStyle

Secure

Silicone

Backlit

Wireless

Corded

Wireless

1- Recommended maximum concentration: 1%. Follow instructions for use of product for appropriate contact time. Do not immerse products in concentrated bleach.

2- Do not use any Hydrogen Peroxide product that contains chelate additives (e.g., glycolic acid, phosphoric acid, citric acid).

3- Recommended concentration: 72%. Do not immerse products in an IPA bath.

3

Seal ShieldTM products have been tested, and proven compatible with most all medical-grade cleaners

& disinfectants (with the exception of acetone)

Page 5: COMPLETE PRODUCT CLEANING GUIDE - Seal Shield

87-SEAL-SHIELD (877-325-7443) | [email protected] SealShield.com

CLEANING GUIDESCREEN PROTECTORS

DISINFECTION INSTRUCTIONSFOR SEAL SHIELDTM SCREEN PROTECTORS

CLEANING GUIDELINES

In cooperation with GE Healthcare, the following fourteen cleaning products were tested against Seal

Shield’s Multilayer Screen Protectors for at least 24 hours of exposure time:

• PDI Super Sani-Cloth

• PDI Sani-Cloth bleach

• Ethanol 70%• PDI Easy Screen [IPA 70%]

• AVERT

• PDI Sani Cloth AF3• Clinell Sporicidal Wipes

• Clinell Universal Range• Cleanisept Wipes

• Mikrozid Sensitive Wipes

• Virex 5

• Caviwipes• PDI Sani Cloth Plus

• Clorox Hydrogen Peroxide

• Oxivir HC

• Oxivir Excel

These products are considered appropriate for use at all times with Seal Shield Multilayer Screen Protectors.

• Bleach and IPA 70% were tested using

hand wiping at 3 minutes per cycle with good results.

• Seal Shield Multilayer Screen Protectors can also safely be cleaned with other manufacturers bleach-based and non‐bleach‐based cleaners, as well as Quaternary Ammonium Germicidal Wipes f rom SafeTec, STERIS, Jet, etc.

4

RECOMMENDED MEDICAL-GRADE CLEANING PRODUCTS

Seal Shield products have been tested, and proven compatible with most medical-grade

cleaners & disinfectants (with the exception of acetone), as well as disinfection using the

ElectroClaveTM UV-C disinfection system.

Page 6: COMPLETE PRODUCT CLEANING GUIDE - Seal Shield

87-SEAL-SHIELD (877-325-7443) | [email protected] SealShield.com

CLEANING GUIDE

5

ElectroClave can disinfect a non-porous, hard surface device achieving a 99.9% reduction

of MRSA, S. aureus, E. coli, and CRE. Prior to disinfection, devices must be pre-cleaned to

remove any accumulated debris. The ElectroClave’s UV-C LED light will not penetrate

through any built-up materials, including common salt (NaCl) left after using bleach, sand

and rock found in dirt, body fluids, and oil. Regular pre-cleaning of devices prior to disinfection

in the ElectroClave is strongly recommended. Cleaning should involve a wiping process to

remove all debris from the surface of the device. Please consult with your local infection

control practitioner for protocols on wiping device surfaces and establishing

disinfection frequency.

ELECTROCLAVE TM

CLEANING & DISINFECTION

GUIDELINES FOR USE

NON-CRITICAL MEDICAL DEVICESThe ElectroClave should only be used on non-critical medical non-porous, hard surface devices. Non-critical would define any

device that comes into contact with intact skin (excluding mucous membranes). Some examples of non-critical equipment would

be phones, pagers, tablets and bar code scanners.

DEVICE ORIENTATIONIn order to maximize UV-C exposure in the ElectroClave, devices cannot be stacked on top of each other in the same disinfection

bay. If disinfecting a small device where more than one device is placed on the same disinfection shelf, there should be at least

two inches of space between the two devices. Tablets should be centered on the device shelf as accurately as possible. If you use

the USB charging feature, ensure the charging ports of the devices are facing the front door. The charge USB cable should not

drape across the glass shelf. The excess USB charging cable should be hanging in front of disinfection modules and front door.

CLEANING & DISINFECTION OF THE

ELECTROCLAVE TM

ElectroClave™ surfaces that can be cleaned and disinfected are identified below. Isopropyl Alcohol 72% or higher

can be used to wipe and clean these surfaces.

1

2

3

4

5

THE SURFACES IDENTIFIED BELOW SHOULD

NOT BE SPRAYED, ONLY WIPED.

Surfaces That Can be Wiped

1

2

3

4

5Left side panel

Keypad & LED display

LED charge indicator

NFC badge reader

Front door, front window, front bezel

6

7

8

67

8

Disinfection module caps

Quartz device shelves

Top cover

QUARTZ SHELVES

MAINTENANCE FREQUENCY

ElectroClave’s quartz shelves should be cleaned

any time inorganic or organic matter including

fingerprints, smudges, dirt, oil, or dried fluids can

be visible on its surface. It is best to leave the quartz

shelves in the unit and use an isopropyl alcohol (IPA)

wipe 72% or greater to clean the surface. Do not

spray alcohol inside the ElectroClave™. IPA can be

applied to a microfiber cloth and the cloth can then be

used to wipe the quartz. If the quartz shelves need to

be removed in order to clean fully please refer to

section Quartz Device Shelves Installation or

contact your local dealer.

ELECTROCLAVE