KITFixture and Restorative

Components

OSSTEMIMPLANTSYSTEM

Page 2: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

32

Contents | OSSTEM IMPLANT

KIT

10New

Hanaro KIT

11GS KIT

11GS II

Mini KIT

10Simple KIT

13MS KIT

12Taper KIT

12Taper Mini KIT

15Sinus KIT

14Ortho KIT

17Prosthetic KIT

20Cortical Drill 3

for GSIII/New

SSIII

20Taper

Cortical Drill 3

for GSIII/New

SSIII

20Taper Drill

for GSIII/

New SSIII

21I - Drill

17GS Prosthetic KIT

16Ridge Split KIT -

straight/offset

15Osteo KIT

18Guide Drills

18Sidecut Drill

13Ultra KIT

16Bone Spreader KIT

14Custom KIT

19Three Cutter

Twist Drill

21Drill Extension

22Long Shank

Pilot Drill

22Simple

Mount Driver

22Simple

Mount

Extension

23Simple

Open Wrench

23Tissue Punch

23Tissue

Punch Drill Guide

24Trephine Drill

24Trephine Guide

24Ratchet Wrench

25Finising

Reamer Set

25Reamer Bite

25O-ring

Abutment

Driver

25Dalbo

Plus Screw

Driver

26Hand Driver

26Machine

Screw Driver

26Driver Handle

27Torque Wrench

27Torque Driver for

Torque Wrench

27OSSTEM

Torque Driver

28Tapered

Fixture Counter

Drill

for USIII

28Tapered

Fixture Tap

for USIII

28Parallel Pin

28Depth Gauge

27Removal Tool for

Fixture Mount

29Reverse Tap

29Positioning

Guide

33Surgical Tap

for SS II

29Reverse Drill

29Bone Mill

35Reamer Tip

33Depth

Gauge Pin

for SS II

34Solid

Abutment

Driver

35Excellent

Solid

Abutment

Driver

35Octa

Abutment

Driver

34SS

NoMount

Driver

33SS

Long Shank

Countersink

36US Straight

Surgical Tap

36Depth

Gauge Pin

34SS

Fixture

Driver

37US Fixture

Driver

37US NoMount

Driver

30

Surgical

Dual Tap

37Bone Profiler

36US Long Shank

Countersink

30GS

Fixture

Driver

31Rigid Outer

Driver

30GS

NoMount

Driver

32Reamer Tip

32Transfer Abutment

Separate Tool

31Path probe

31GS

Bone Profiler

31GS Tissue

Heigth Gauge

38Ultra Wide

Drill

38Ultra Wide

Surgical Tap

39Ultra Wide

Trial Pin

Page 3: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

5

KIT

4

KIT

OSSTEM IMPLANT R&D Center

Universities/Other

Research InstitutesEducational-industrial projects

GovernmentResearch cooperation with

governmental projects

Customer ClinicsFeed Backs/opinions

Associated Clinical Hospital

Joint clinical research works

OSSTEM IMPLANT

R&D Center

OSSTEM IMPLANT

●Market Share & Brand Recognition NO. 1 In Korean Market

●World Class Product Quality(FDA, CE, ISO9001)

●Enhanced Research & Development Through Impant R&D Center

●Independent Models Development and Production(SSII, GSII)

●A Wide Range of Products with Excellent Compatibility

●Most Advanced Facilities with the Largest Production Capacity in Asia

●Export to the worldwide

●Future Expansion Plan To Over 100 Countries For The Next Five Years

●Active Systematic Impant Clinical Training Through AIC Center

OSSTEM IMPLANT R&D Center

OSSTEM R&D Center consists of 25 professionals who

have doctral/master’s degree in each field.

OSSTEM keeps investing in research and development

area with high tech equipment.

OSSTEM also cooperates with government agencies,

universities, and hospitals in many projects and in-depth

studies.

OSSTEM HISTORY

May Developed and commenced the commercial production of GSII

Apr "OSSTEM MEETING 2005" held in Seoul

(2,700 attendees)

Mar Certified KGMP(Korean Good Manufacturing Practice) in Korea

Published the "2005 OSSTEM IMPLANT SYSTEM (Introduction)"

Jan Established the subsidiary office in Taiwan(Taipei)

Nov Developed and commenced the commercial production of SSIII

Jul Developed and commenced the commercial production of USIII

Apr "OSSTEM MEETING 2004" held in Seoul (1,200 attendees)

Nov Developed and applied its own automatic cleaning system

Jul Established the OSSTEM Information System R&D Center

Oct Developed and commenced the commercial

production of SSII

Aug Developed and commenced the commercial

production of USII Approved by the FDA in the US

Mar Concluded partnership agreement with KaVo(Kaltenbach & Voigt)

Jan Established the OSSTEM Implant R&D Center

Mar Established the AIC

(Apsun Dental Implant Research & Education Center)

Jan CE-0434 Mark certified

Oct Certified ISO-9001

Dec Commenced the commercial production

(brand name : OSSTEM)

Jan Established the Company in Korea

(OSSTEM Co., Ltd.)

Developed the implant and acquired an industrial license

Launched the development of dental implant system

2009

2007

2005

2008

2006

2005

2003

2001

1997

1992

2004

2002

1999

1995

Oct Approved by the Ministry of Health, Labour and Welfare in Japan

Aug ‘2009 OSSTEM MEETING Hong Kong’ held

Oct '2008 OSSTEM MEETING Singapore' held

Aug '2008 OSSTEM MEETING Hong Kong' held

Jul '2008 OSSTEM MEETING Taiwan' held in Taipei

Jun Development and sales of GSIII implant

Apr '2008 AIC World Meeting' held in Seoul

Mar Established ATC training center

'2008 OSSTEM MEETING Thailand' held in Bangkok

Jan Established OSSTEM Bone Science Institute

Nov ‘2007 OSSTEM MEETING Malaysia’ held in Kuala Lumpur

‘2007 OSSTEM MEETING USA’ held in Los Angeles

Oct ‘2007 OSSTEM MEETING India’ held in Mumbai

‘2007 OSSTEM MEETING Russia’ held in Moscow

Established the incorporate subsidiary in Australia(Sydney)

Sep ‘2007 OSSTEM MEETING Hong Kong’ held

‘2007 OSSTEM MEETING Singapore’ held

Jul ‘2007 OSSTEM MEETING Taiwan’ held in Taipei

Jun Approved by the TGA in Australia

May KFDA approved OSSTEM tissue bank foundation

Apr Published "2006 OSSTEM IMPLANT SYSTEM" in English Version

"OSSTEM MEETING 2007" held in Seoul (12,000 attended)

Feb Listed on KOSDAQ (KRX : Korea Exchange)

Dec Established the subsidiary offices in

Thailand(Bangkok), and Malaysia(Kuala Lumpur)

Nov Approved by the SFDA in China

Sep Established the U.S Corporate Headquarter and started

construction of manufacturing facility in the US

Aug Established the subsidiary offices in

China(Beijing), Hongkong, and Singapore

Jul Established the subsidiary office in Japan(Tokyo)

Apr Certified GOST-R in Russia

"OSSTEM MEETING 2006" held in Seoul

(6,500 attendees) Published the "2006 OSSTEM IMPLANT SYSTEM

(introduction and particulars of implant system)"

Jan Established the subsidiary offices in India(Mumbai)

and Russia(Moscow)

Dec Completed, relocated new production plant in Busan

Established the subsidiary office in Germany(Ashborn)

Approved by the DOH in Taiwan

Page 4: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

76

Hanaro KIT System Guide

OS

MS

Ortho KIT(OOKS)

MS KIT(OMSK)

Guide Drill

Sidecut Drill

Parallel Pin

Hand Driver

Torque Driver SS Fixture

Driver

GS Fixture

Driver

No Mount

Driver

Removal Tool

for Mount

Drill Extension

Simple Open WrenchCortical Drill 3 Ratchet Wrench Depth Gauge

Long Shank Pilot Drill

US Long Shank

Countersink

SS Long Shank

Countersink

SS II Surgical TapUS II Surgical Tap

Simple Mount Extension

Simple Mount DriverTwist Drill

Cortical Drill 2

Surgical

US

SS

IIHanaro KIT(HKA2), Simple KIT(OSPK) Prosthetic KIT

(OPK)

Ridge Split KIT

(ORSSK/ORSOK)

Osteotome KIT(AOST)

Osteo KIT(OSTK)

Sinus KIT(ASLK)

Bone Spreader KIT

(OBSOK)

Prosthetic Etc

각 System별 적용 가능한 KIT

IIIHanaro KIT(HKA2), Simple KIT(OSPK)

Taper KIT(OTSK), Taper Mini KIT(OGS3MK)

Ultra

II

III

Ultra

Ultra KIT(OUK)

Hanaro KIT(HKA2), Simple KIT(OSPK)

Hanaro KIT(HKA2), Simple KIT(OSPK)

Taper KIT(OTSK), Taper Mini KIT(OGS3MK)

Ultra KIT(OUK)

Surgical

GS

IIGS KIT(OGSK2), GS Mini KIT(OIKGM)

Hanaro KIT(HKA2)

Prosthetic KIT

(OPK)

GS Prosthetic

KIT(GSPK)

Ridge Split KIT

(ORSSK/ORSOK)

Osteotome KIT(AOST)

Osteo KIT(OSTK)

Sinus KIT(ASLK)

Bone Spreader KIT

(OBSOK)

Prosthetic Etc

각 System별 적용 가능한 KIT

IIITaper KIT(OTSK), Taper Mini KIT(OGS3MK)

GS KIT(OGSK2), GS Mini KIT(OIKGM), Hanaro KIT(HKA2)

Ultra Ultra KIT(OUK)

Page 5: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

OSSTEMIMPLANTSYSTEMKITFixture and RestorativeComponents Early & Esthetic

OSSTEM IMPLANT

KIT

Page 6: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

11

KIT

10

KIT

New Hanaro KIT

Surgical KITsGLOBAL STANDARD OSSTEM IMPLANT

GS II Mini KIT

OSPK

● Affordable expert surgical KIT

● Tools designed for the grafting of all Osstem implant fixtures

● 15mm no stopper drill

Simple KIT

GS KIT

OIKGM

● GS II Fixture Surgical KIT

● Has minimum tools needed for the GS II System

● Consists of I-Drill(Type I/II) for surgery conveniently

● The color line is designed for the different diameters of GS II

fixtures, thereby facilitating the selection of the desired tool

for surgery.

HKA2

● Integration surgical KIT for fixtures of all system

● Upper Case : Semi-transparent design facilitates internal observation

● Middle Case (upper structure) : Color line and color rubber enable the easy selection of tools for fixture grafting

● Middle Case (lower structure) : Enables connection to the bottom box ; comes with a handle to facilitate movement

● Lower Case : Comes with a steel box for storing the tools used for surgery

OGSK2

● GS II Fixture Surgical KIT

● Has all the tools needed for the GS system procedure

● Drill with a stopper helping a beginner perform surgery conveniently

● The color line is designed for the different diameters of GS fixtures and bone conditions, thereby facilitating the

selection of the desired tool for surgery

● The new Sidecut drill and NoMount driver make implant treatment easy

● Heat- and shock-resistant engineering plastic material

Page 7: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

13

KIT

12

KIT

Surgical KITsGLOBAL STANDARD OSSTEM IMPLANT

Taper KIT

Trial pins (2 type)

- ∅5.5 Trial Pin

- ∅6.5 Trial Pin

Etc (3 types)

- Simple Mount Driver

- 1.2 Hex Hand Driver

- Open Wrench

Ultra KITTaper Mini KIT

OGS3MK

● GS III & NEW SS III Fixture Surgical KIT

● The KIT consists of Straight Drill similar to Fixture shape

● 15mm Long Drill and Cortical Drill

● Has minimum tools enable the easy surgery

● The new Sidecut drill and NoMount driver make implant treatment easy

OTSK

● GS III & NEW SS III Fixture Surgical Tool

● The KIT consists of Taper Drill similar to Fixture shape

● The line enables the easy surgery for fixture with bone condition

● The new Sidecut drill and NoMount driver make implant treatment easy

● Stopper of Straight drill consists of short stopper

MS KIT

OMSK

● Drills : 5 types

● Drivers : 4 types

● Gauge : 3 types

OUK

● Ultra-Wide fixture surgical KIT

● KIT Components

Drills (4 types)

- ∅4.6 Three Cutter

Twist Drill

- ∅5.5 Direct Drill

- ∅6.5 Direct Drill

- ∅2.0 SideCut Drill

Surgical taps (2 types)

- ∅6.0 Surgical Tap

- ∅7.0 Surgical Tap

Trephine drills (2 types)

- ∅4.2 / ∅5.0 Trephine Drill

- ∅5.2 / ∅6.0 Trephine Drill

Page 8: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

15

KIT

14

KIT

Ortho KIT

Sinus KITCustom KIT

Osteo KIT

OOKS

● Orthodontic Treatment KIT

● Comes with a disinfectable tray for storing

orthodontic screws

● Drills (2 types)

1. ∅1.3 Drill

2. ∅1.5 Drill

● Drivers (4 types)

1. Driver Tip (Hex Type)

2. Driver Tip (Cross Type)

3. Machine Driver (Hex Type)

4. Hand Driver (Hex Type)

● Handles (2 types)

1. Universal Handle

2. Driver Handle

OSTK● Concave Osteotome : Use for maxillary sinus elevation for the vertical

expansion of the volume of alveolar bone available in the maxillary posterior

● Expanding Osteotome : Without cutting low-quality bone, the preservation ofthe bone densifies the bone trabeculato enhance the initial bonding of implants

● Stopper for the adjustment of surgical depth

※ Components 2.0, 2.5, 3.0, 3.5, 4.0 Concave Osteotome / 2.0, 2.5, 3.0, 3.5, 4.0 Expanding Osteotome / New Mallet

Osteotome : OST20CA, OST25CA, OST30CA, OST35CA, OST40CA, OST20EA, OST25EA, OST30EA,

OST35EA, OST40EA

New Mallet : OSTMP / New Osteotome set: OSTK

ASLK

● Compact design

● Various types of tools (5) used for the sinus procedure

※ 5 components

Freer Elevator : OFE

Bone Graft Carrier : OBGC

Membrane Separator (Circle type) : OMSC

Sinus Curette : Short - OSCS

Sinus Curette : Long - OSCL

OCTK

● When only part in the surgical operation organization

sterilization, uses.

● Composition of additional rubber (small, middle, large)

● Use for autoclave (132 , 15min)

Surgical KITsGLOBAL STANDARD OSSTEM IMPLANT

Concave type Expanding type

Stopper

: move by rotation

AOST● Use for maxillary sinus elevation for

the vertical expansion of the volume ofalveolar bone available in themaxillary posterior

● Includes only the concave type

※ Components 2.5, 3.0, 3.5, 4.0 Osteotome, Mallet

Osteotome : OST25, OST30, OST35, OST40

Osteotome Mallet : OSTM

Osteotome set: AOST

Page 9: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

17

KIT

16

KIT

Ridge Split KIT - straight/offset

Bone Spreader KIT

● Chisel : Use for alvelar bone expansion

● Blade Holder : enables malletting for soft bone

● Straight type (ORSSK)

● Offset type (ORSOK)

OBSOK

● Use for alvelar bone expansion

● Offset type for easy operation

※ Components

OBSO22F, OBSO28F, OBSO35F, OBSO35R

Prosthetic KIT

OPK

● Prosthetic treatment KIT

※Components

● Drivers(15 types)

1. 1.2 HexTorque Driver(Short/Long)

2. 1.2 Hex Machine Driver(Short/Long)

3. 1.2 Hex Hand Driver(Short/Long)

4. 0.9 Hex Hand Driver(Long)

5. O-ring/Octa/Solid/Excellent Solid Abutment Driver

6. Rigid Driver(∅4.0, ∅4.5, ∅5.0, ∅6.0)

● Others(3 types)

1. Torque Handle

2. Torque Wrench

3. Stainless Steel Bowl

GS Prosthetic KIT

GSPK

● GS Prosthetic treatment KIT

● Drivers(10 types)

1. 1.2 Hex Torque Driver(Short/Long)

2. 1.2 Hex Hand Driver(Short/Long

3. O-ring/Octa Driver

4. Rigid Driver(∅4.0, ∅4.5, ∅5.0, ∅5.5)

● Others(4 types)

1. Torque Handle

2. Torque Wrench

3. Stainless Steel Bowl

4. GS Path Probe(Mini, Standard)

Surgical KITs Prosthetic KITsGLOBAL STANDARD OSSTEM IMPLANT

0

8.57

11.510

Thickness

Width

(Unit : mm)

7 8.5 10 11.5

7

10

0

8.5

11.5

Width : 4mm Thickness

ORSSK※ Components

Ridge Split Chisel : ORSS15, ORSS20, ORSS25, ORSS30

Blade Holder : ORSBH

Code Spec.

Tip length

ORSOK※ Components

Ridge Split Chisel : ORSO15, ORSO20, ORSO25,ORSO30

Blade Holder : ORSBH

ORSS15 Thickness 1.1 1.27 1.5 1.5

ORSO15 Width 4 4 4 4

ORSS20 Thickness 1.45 1.7 2.0 2.0

ORSO20 Width 4 4 4 4

ORSS25 Thickness 1.8 2.15 2.5 2.5

ORSO25 Width 4 4 4 4

ORSS30 Thickness 2.15 2.5 3.0 3.0

ORSO30 Width 4 4 4 4

(Unit : mm)

7 8.5 10 11.5Code Spec.

Tip length

Thickness 1.15 1.3 1.45 1.6

Width 2.1 2.2 2.2 2.2

Thickness 1.15 1.3 1.45 1.6

Width 2.65 2.8 2.8 2.8

Thickness 1.3 1.45 1.6 1.8

Width 3.3 3.5 3.5 3.5

Thickness 1.85 2.1 2.3 2.55

Width 3.3 3.5 3.5 3.5

OBSO22F

OBSO28F

OBSO35F

OBSO35R

(Round Type)

Page 10: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

19

KIT

18

KIT

78.510

Three Cutter Twist Drills

Long Stopper Drill

OSSTEM IMPLANT SYSTEMM R W Fixture Diameter

1

L

Drill Tip

● Long stopper (6 mm) : Posterior surgery may be performed even without drill extension

● The color coding on the stopper indicates the drill length

● The tip length of a 2.0 twist drill is 0.6 mm, and the other tip length of drills, 0.8mm~1mm

● Cuts the stopper of a 15 mm drill to facilitate depth adjustment in the ridge

● The laser marking indicates the length, thereby enabling all drilling lengths (7-15 mm) using one drill

● Handles are color-coded to indicate drill length

● For sufficient intermaxillary gap as in the anterior part, drilling may be performed even without drill extension

● The laser marking indicates the length, thereby enabling all drilling lengths (7-15 mm) using one drill

● Handles are color-coded to indicate drill length

No Stopper Drill

Extra Long Drill

Long Stopper Drill No Stopper Drill Extra Long Drill

∅2.0 ∅3.0 ∅3.3 ∅3.6 ∅3.8 ∅4.1 ∅4.3 ∅4.6

7 TDE2007LC 3D3007LC01 - - 3D3807LC01 - - -

8.5 TDE2008LC 3D3008LC01 - - 3D3808LC01 - - -

10 TDE2010LC 3D3010LC01 - - 3D3810LC01 - - -

11.5 TDE2011LC 3D3011LC01 3D3311LC01 3D3611LC01 3D3811LC01 3D4111LC01 3D4311LC01 3D4611LC01

13 TDE2013LC 3D3013LC01 - - 3D3813LC01 - - -

L D

∅2.0 ∅2.7 ∅3.0 ∅3.15 ∅3.3 ∅3.6 ∅3.8 ∅4.1 ∅4.3 ∅4.6

15 TDE2015FNLC 3D2715FNLC01 3D3015FNLC01 3D3115FNLC01 3D3315FNLC01 3D3615FNLC01 3D3815FNLC01 3D4115FNLC01 3D4315FNLC01 3D4615FNLC01

∅2.0 ∅2.7 ∅3.0 ∅3.15 ∅3.3 ∅3.6 ∅3.8 ∅4.1 ∅4.3 ∅4.6

15 TDE2015FNEC 3D2715FNEC 3D3015FNEC 3D3115FNEC 3D3315FNEC 3D3615FNEC 3D3815FNEC 3D4115FNEC 3D4315FNEC 3D4615FNEC

Sidecut Drill

Guide Drills

● Lance Drill : - Forms holes in the bone to facilitate initial drilling

- Bone density can be determined through drilling

- TiN coating improves anti-corrosion and wear resistance

● Enables the bodily change of drilling direction

● Used to cut the ridge of the extracted socket

● Facilitates site preparation in the extracted socket

Surgical Tool for OSSTEM IMPLANT SYSTEM

: Standard Tools

Code

Type D

Short

Long

∅1.5

OSLMDS

OSLMDL

∅2.0

OSLMD20S

OSLMD20L

Short Long

Lance Drill Type Code

Short AGDSC

Long AGDLCLance Drill

13

20

D D

L D

L D

Short Long

17

12

57

8.510

Page 11: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

21

KIT

20

KIT

● To embody concurrently both Pilot Drill and Twist Drill

● To minimize bone heating during drilling

● Protection for membrane with round shape guide during maxillary sinus surgery

● Refer to GS II Mini KIT(OIKGM) for exclusive using I-Drill

OSSTEM IMPLANT SYSTEMM R W Fixture Diameter

I-Drill

Spec.I-drill 1 I-drill 2

∅2.0/∅2.7 ∅2.0/∅3.0 ∅2.0/∅3.3 ∅3.3/∅3.8 ∅3.3/∅4.3 ∅2.0/∅3.8 ∅2.0/∅4.3

Code OID2027C* OID2030C* OID2033C* OID3338C* OID3343C* OID2038C** OID2043C**

∅A 2.0 2.0 2.0 2.0 2.0 2.0 2.0

∅B - - - 3.3 3.3 3.0 3.0

∅C - - - - - - 3.8

∅D 2.7 3.0 3.3 3.8 4.3 3.8 4.3

(Unit : mm)

∅D

∅A

∅D

∅B

∅A

∅D∅B

∅A

∅B

∅D∅C

4.5

1

15

1311.5

108.575433

*: I-drill 1 **: I-drill 2

� � � � � � �

∅2.0/∅2.7

∅2.0/∅3.0

∅2.0/∅3.3

∅3.3/∅3.8

∅3.3/∅4.3

∅2.0/∅3.8

∅2.0/∅4.3

Spec. ∅3.5 ∅4.0 ∅4.5 ∅5.0

Code CD4C35 CD4C40 CD4C45 CD4C50

Spec. ∅3.5 ∅4.0 ∅4.5 ∅5.0

Code TCD4C35 TCD4C40 TCD4C45 TCD4C50

Cortical Drill 3

for GSIII / New SSIII

● Cortical bone expansion Drill after using Straight Drill

● Using drill with final hole more than normal bone

● Processing exclusive use Drill for fixture diameter

● The lowest marking line is normal bone and the highest marking line is hard

bone

● It is recommend that drilling performs up to marking line

Taper Cortical Drill

for GSIII / New SSIII

● Cortical bone expansion Drill after using Taper Drill

● Using drill with final hole more than normal bone

● Processing exclusive use Drill for fixture diameter

● It is recommend that drilling performs up to marking line

Taper Drill

for GSIII / New SSIII∅3.5 ∅4.0 ∅4.5 ∅5.0

7 TPD3C3507 TPD3C4007 TPD3C4507 TPD3C5007

8.5 TPD3C3508 TPD3C4008 TPD3C4508 TPD3C5008

10 TPD3C3510 TPD3C4010 TPD3C4510 TPD3C5010

11.5 TPD3C3511 TPD3C4011 TPD3C4511 TPD3C5011

13 TPD3C3513 TPD3C4013 TPD3C4513 TPD3C5013

15 TPD3C3515 TPD3C4015 TPD3C4515 TPD3C5015

● Processing exclusive use Taper Drill for III fixture diameter and length

● Stopper drill with 1mm margin

● Color coding on the shank indicates the drill diameter

(∅3.5:Yellow, ∅4.0:Green, ∅4.5:Blue, ∅5.0:Red )

● The tip length is 0.8mm~1.0mm

L

1mmStopper

Color coding

for Diameter

Spec.L

Drill Extension

● Extends the length a drill and other hand tools

● Insertion into an O-ring offers a holding function

● Use by connecting the flat side of the drill handle to the flat side of the drill

extension

● The use of too much force is prohibited

Code ADE

Page 12: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

23

KIT

22

KIT

Simple Open Wrench

● For weak bone, use to separate the simple mount

● 30。neck angle enhances convenience of insertion in the oral cavity

Simple Mount Driver

● Use for fixture grafting by connecting to a simple mount

● Compact design, internal holding function

Length L Code

Short 20.1 ASMDS

Long 26.5 ASMDL

Short Long

● Used for the path adjustment of a drilling hole

● When using the next size drill, the guide hole enables precise cutting

● TiN coating improves anti-corrosion and wear resistance

Long Shank Pilot Drill ∅A ∅B Mini Regular Wide

2.0 2.7 APD270C - -

2.0 3.0 - APD300C -

3.0 3.8 - - APD380C

3.0 4.1 - - APD410C

∅A

∅B

21.4

L

∅4.8

3.2

Tissue Punch ∅A(mm) Code Application

3.8 OSTP38 US Mini, GS ∅3.5

4.3 OSTP43 US Regular, SS Regular, GS ∅4.0

4.8 OSTP48 GS ∅4.5

5.3 OSTP53 US Wide, SS Wide, GS ∅5.0

● Used by connecting to the engine; enables manual gingival cutting if

necessary by connecting with the handle

● Tool to be used for flapless surgery

● The laser marking at 2-mm intervals enables the measurement of gingival height

● With SS Wide fixtures, a surgeon may choose between OSTP48 and OSTP53

● Packing unit : Tissue Punch + Guide Pin

OSSTEM IMPLANT SYSTEMM R W Fixture Diameter

Code ASOW

24

6

∅A

Simple Mount Extension

● Use for the extension of fixture mount length by connecting to a torque

wrench

Length L Code

Short 11.2 ASMES

Long 20.5 ASMEL

Short Long

L

∅4.8

L

Page 13: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

25

KIT

24

KIT

Reamer Bite

● TiN coating improves anti-corrosion and wear resistance

Finishing Reamer Set

● Use to remove the lip inside the casting body upon the casting of plastic

copings

O-ring Abutment Driver

Dalbo Plus Screw Driver

● Use for the adjustment of retention force of a Dalbo plus attachment

● Special-purpose driver for the O-ring abutment

2.4

OSSTEM IMPLANT SYSTEMM R W Fixture Diameter

Ratchet Wrench

● Only surgical unlimited wrench (Not adjustable torque value)

Code CITQW-1185A

Code AORD

Code ODSD

Code FRSC

Code FRBC

18.5

∅4

Trephine Drill

● Use for the collection of bone or removal of damaged or failed fixtures

● Packing unit : Trephine Drill

A

B

Code Inner Dia.(∅) Outer Dia.(∅)길이(mm)

A B

TD37S 3.7 4.5 16.6 31

TD42S 4.2 5.0 16.6 31

TD47S 4.7 5.5 16.6 31

TD52S 5.2 6.0 16.6 31

TD62S 6.2 7.0 16.6 31

TD37 3.7 4.5 22 36.4

TD42 4.2 5.0 22 36.4

TD47 4.7 5.5 22 36.4

TD52 5.2 6.0 22 36.4

TD62 6.2 7.0 22 36.4

Page 14: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

27

KIT

26

KIT

Hand Driver Length(mm)

Type Short Long Application

0.5Slot ASD05SH ASD05LH Cylinder Screw

0.9Hex AHD09SH AHD09LH Cover Screw

2.7 Int. Hex Wide Esthetic-low Abutment Screw

1.2Hex AHD12SH AHD12LHHealing Abutment,UCLA,

CementedAbutment Screw, Mount Screw

Esthetic Abutment Screw Regular

Esthetic-low Abutment Screw, Standard 2.0 Int. Hex IHD20H

IHD27H

Length(mm)

Type Short Long Extra Long Application

0.5Slot TRSD05S TRSD05L TRSD05E Cylinder Screw

0.9Hex TRHD09S TRHD09L - Cover Screw

2.7Int. Hex TIHD27

1.2Hex TRHD12S TRHD12L TRHD12E

-

Healing Abutment,

UCLA,Cemented Abutment

Screw, Mount Screw

Wide Esthetic-low Abutment Screw

Standard/ Esthetic Abutment

Screw, Regular Esthetic-low

Abutment Screw2.0lnt. Hex TIHD20S TIHD20L

Machine Screw Driver Length(mm)

Type Short Long Extra Long Application

0.5Slot AMSD05S AMSD05L Cylinder Screw

0.9Hex AMSD09S AMSD09L Cover Screw

2.7lnt. Hex Wide Esthetic-low Abutment Screw

1.2Hex AMSD12S AMSD12L AMSD12EHealing Abutment, UCLA, Cemented

Abutment Screw, Mount Screw

Esthetic Abutment Screw Regular

Esthetic-low Abutment Screw,

Standard2.0lnt. Hex EIHD20

EIHD27

Torque Driver for Torque Wrench

Removal Tool for Fixture Mount Code Application

ERFM US Mini, GS Mini

HRFR US Regular, SS Regular/Wide, GS Standard

ERFW US Wide

Slot Hex Int. Hex● Machine screw driver

● No tip holding function

● Manual driver

● Tip holding function (note: excluding Int. Hex Type)

● When a fixture and the fixture mount are stuck, use after removing the

fixture mount screw

● Use after the connection to a driver handle and a torque wrench

● Insert vertically and rotate clockwise

● Driver for torque wrench connection

● No tip holding function

OSSTEM IMPLANT SYSTEMM R W Fixture Diameter

Driver Handle

● Use by connecting with a torque driver

Torque Wrench

● Use for fixture grafting or screw tightening

● Single tool for 10, 15, 20, 25, and 30 Ncm and unlimited torque

● Too much force beyond the allowable level bends the neck

● The laser marking on the handle denotes the torque figures (10, 15, 20, 25,

and 30 Ncm)

● For the application of unlimited torque, grip the body and pull outward prior

to using the tool. Afterward, rotate at 90。to secure

● After use, be sure to separate, clean, and sterilize the tools completely

Code TIDHC

Code TWMW

Slot Hex Int. Hex

Short Long Short Long

Short Long

2.0 Int. Hex 2.7 Int. Hex1.2 Hex

0.5 Slot 0.9 Hex

L

10

8

13

∅10

OSSTEM Torque Driver

● Processing private Driver for OSSTEM Torque

● The triangle mark is used by aligning with the abutment groove

● Tightening torque : 30Ncm(except 1.2 Hex Type)

● Processing private Solid/Excellent Solid Driver Only ∅4.8 type

● Non connection with hand piece

1.2 Hex Short Long

L

ShortType

L 10 15

Long

1.2 Hex OTH12S -

Rigid ∅4.0 OTR40S OTR40L

Rigid ∅4.5 OTR45S OTR45L

Rigid ∅5.0 OTR50S OTR50L

Rigid ∅6.0 OTR60S OTR60L

Solid OTS48S OTS48L

Excellent Solid OTE48S OTE48L

Page 15: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

29

KIT

28

KIT

Parallel Pin Diameter(∅) Code

∅4.0 APP400

∅5.0 APP500

∅6.0 APP600

Full Set APPS

● Use for checking the direction and location for bone preparation

● Predicts the diameter of an abutment to be secured

● Packing unit: Individual and general set packing

Depth Gauge

● A : Measurement of drilling length (7-15 mm)

● B : Measurement of gingival height following external fixture grafting

A

B

B

D

Set : ABMH+ABMC+ABMG+ABMB

● Forms particulate bone using the collected autogenous bone

● Packing unit : Bone mill (1 set)/components

Bone Mill

ABMH

ABMB

ABMG

ABMC

Reverse Drill Drill Mini Regular

Code ARVDMC ARVDRC

● Use to remove broken or damaged screws at the fixtures.

● Drilling speed : 30-50 rpm

● Do not apply too much force when using a reverse drill.

● Mode : Reverse rotation mode

● Packing unit : Reverse drill

Reverse Tap Type Code

For 0.9 Hex ART09C

For 1.2 Hex ART12C

● Use to remove a screw if the hex hole of its head is worn

● Torque : 50 Ncm

● Mode : Reverse rotation mode

● Packing unit : individual and general set packing

OSSTEM IMPLANT SYSTEMM R W Fixture Diameter

Code ADG

Code ABM

Positioning Guide Width(mm) Code

2.5 APG201

6 APG202

11 APG203

● Indicates the distance between fixtures

● Use after the first drilling (2.0)

Tapered Fixture Tap for USIII Fixture Regular Wide

Code OTST40C OTST50C OTST55C

● Special-purpose tap for US III fixture

US III

Fixture Regular Wide

Code TFCD400 TFCD500 TFCD550

Tapered Fixture

Counter Drill for USIII

● Special-purpose tool for US III fixture

US III

W

∅2.0

10

∅2.0

∅D

∅2.7

Page 16: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

31

KIT

30

KIT

Surgical Tool for GSOSSTEM IMPLANT SYSTEMM R W Fixture Diameter

Cortical Drill 3

for GSIII / New GSIII

Spec. ∅3.5 ∅4.0 ∅4.5 ∅5.0

Code CD2C35 CD2C40 CD2C45 CD2C50

● Using after making for final drill hole

● Processing exclusive use Drill for fixture diameter

● It is recommend that drilling performs up to under marking line

Surgical Dual Tap for GSIII

● Use for dense bone and form screw thread-shaped fixtures

● Use a torque wrench after connecting to the engine or mount extension

● TiN coating improves anti-corrosion and wear resistance

Abutment D (∅)

∅3.5

- OGST40SC OGST45SC OGST50SC

OGST35LC OGST40LC - -

∅4.0 ∅4.5

StandardMini

∅5.0

Short

Long

Type D

LongShort

Short

(Mini) (Standard)

Long Short Long

NoMount Driver Mini Standard

Short GSNMD32S GSNMD35S

Long GSNMD32L GSNMD35L

● To enable the simultaneous measurement of gingival height upon

treatment, grooves and laser markings are indicated at 1-mm (1-6 mm)

intervals

● Stopper designed for the prevention of fracture of the holding part and

occurrence of foreign matter such as blood stain during the surgery

Short Long Short Long

Fixture Driver Mini Standard

Short GSMFDS GSRFDS

Long GSMFDL GSRFDL

● Fixture connection

● Use to place or remove a fixture after the separation of the mount

● Enables 150 Ncm torque or more

(Mini) (Standard)

Rigid Outer Driver

● Special-purpose driver for rigid abutment

● Torque : 30Ncm

GS Tissue Heigth Gauge

Path probe Mini Standard

Spec. Mini Standard

Short GIPAP-3016A GIPAP-3516A

● After GS NoMount driver, confirmation path and measurement gingival height

● For mini : yellow color

● For standard : green color

● Measurement gingival height for selecting optimal abutment

● Non gloss treatment for improving identification

Short

∅ 4.0Abutment D(∅ ) ∅ 4.0 ∅ 4.5 ∅ 5.0 ∅ 6.0

ORDMS ORD45S ORDRS ORDWS

ORDML ORD45L ORDRL ORDWLLong

Code GTHGS

● Use to remove the bone around the fixture during the first or second surgery

● The guide screw protects the morse taper of the fixtures

● Packing Unit : Bone Profiler + Guide Screw

Connection

Mini

&

Standard

GSBP45

GSBP55

GSBP75

∅4.5

∅5.5

∅6.5

∅7.5

Healingabutment직경

Bone Profiler사양 Guide Screw

Mini

Connection

Standard

Connection

GS Bone Profiler

Page 17: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

33

KIT

32

KIT

Surgical Tool for SS

Type Code

Driver TASD

Body TASB

Set TAST

Transfer Abutment Separate Tool

Driver

Body

● Use to remove a non-Hex transfer abutment stuck in fixtures due to morse

taper contact

● Mini-types are intended for the body tip ; standard types are commonly

used by inserting into a double-layer groove

● After removing the abutment screws, insert the separated tool body into

the internal hole of the abutment and tighten the driver clockwise. Once

the body and the abutment are aligned, they can be separated easily

In case separation is difficult, try after the connection of a torque wrench

to the driver

Reamer Tip

∅5.0∅4.5∅4.0 ∅6.0

● When fabricating the prosthesis using a Rigid plastic coping, it is used for

margin contact adjustment.

Abutment D (∅) ∅4.0

GSRFRT400 GSRFRT450 GSRFRT500 GSRFRT600

∅4.5 ∅5.0 ∅6.0

Code

Depth Gauge Pin for SS II

Platform ∅4.8 ∅4.8 ∅6.0

TypeD ∅4.1 ∅4.8

Short OSST41SC OSST48SC

Long OSST41LC OSST48LC

Diameter(∅) ∅3.6 ∅4.3

Code ASDG360 ASDG430

Short

Surgical Tap for SS II

Long

● Use for dense bone and form screw thread-shaped fixtures

● Use a torque wrench after connecting to the engine or mount extension

● TiN coating improves anti-corrosion and wear resistance

● Measure the depth after the final drilling

10

∅2.0

D

Long Shank Countersink

∅A

∅B

∅A ∅B Regular Wide Wide Platform

3.5 4.8 ASCD350C - -

4.2 4.8 - ASCD420C -

4.2 6.0 - - ASCDW420C

● Form fixture platform

● Cut down to the bottom of the laser marking

Page 18: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

35

KIT

34

KIT

Solid Abutment Driver

Short

Long

Length Type Square Round

Short SDSS SDRS

Long SDSL SDRL

● Solid abutment private driver

● The triangle mark is used by aligning with the abutment groove

● Tightening torque : 30Ncm

Length Type Regular Wide

Short SSNOMD39RS

Long SSNOMD39RL

NoMount Driver

Short Long

● To enable the simultaneous measurement of gingival height upon

treatment, grooves and laser markings are indicated at 1-mm intervals

(1-2 mm)

● Since the shape is similar to that of the internal fixture driver, even a high

torque does not change the inside of the fixture

● Stopper designed for the prevention of fracture of the holding part and

occurrence of foreign matter such as blood stain during surgery

Fixture Driver Plaftorm(∅) Regular Wide

Short SSRFDS

Long SSRFDL

Short Long

● The laser marking is designed for checking during the connection of a

fixture

● Use for removal following fixture grafting and mount separation

● 150 Ncm torque is applicable

Octa Abutment Driver

Short

Long

Excellent Solid Abutment Driver

Short

Long

● Excellent solid abutment private driver

● The triangle mark is used by aligning with the abutment groove

● Tightening torque : 30Ncm

● Octa abutment private driver

● Tightening torque : 30Ncm

Length Type Square Round

Short ESDSS ESDRS

Long ESDSL ESDRL

Length Type Square Round

Short ODSS ODRS

Long ODSL ODRL

Abutment D (∅) ∅4.8 ∅6.0

Solid FRTS480 FRTE480

Excellent Solid FRTE480 FRTE600

Reamer Tip

Regular Wide

∅4.8 ∅6.0

● Combined use of Solid ∅6.0 and Excellent Solid ∅4.8

OSSTEM IMPLANT SYSTEMM R W Fixture Diameter

Page 19: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

37

KIT

36

KIT

OSSTEM IMPLANT SYSTEMM R W Fixture DiameterSurgical Tool for US

TypeD 3.3 3.75 4.0 5.0

Short - OUST37SC OUST40SC OUST50SC

Long OUST33LC OUST37LC OUST40LC -

Surgical Tap for USIII

● Use for dense bone and form screw thread-shaped fixtures

● Use as a torque after connecting to the engine or a simple mount

extension

● TiN coating improves anti-corrosion and wear resistance

Short Long

Length(mm) Code

7 ADP607

8.5 ADP608

10 ADP610

11.5 ADP611

13 ADP613

15 ADP615

Full Set ADP600

● Convenient top design facilitates depth drilling

● Packing unit : Individual and general set packing

Depth Gauge Pin

10

L - 0.4

∅2.0

∅4.0

∅3.0

Long Shank Countersink ∅A ∅B Mini Regular Wide

2.6 3.5 ACD330C - -

2.9 4.1 - ACD375C

4.2 5.1 - - ACD500C

∅A

∅B

● Forms space for the fixture flange

● Cut down to the bottom of the laser marking

Short Long Short Long Short Long

NoMount DriverLength

Type Mini Regular Wide

Short USNMD35MS USNMD41RS USNMD51WS

Long USNMD35ML USNMD41RL USNMD51WL

Fixture Driver

Platform(∅) Mini Regular Wide

Code USMFDL USRFDL USWFDL

● To enable the simultaneous measurement of gingival height upon

treatment, grooves and laser markings are indicated at 1-mm (1-6 mm)

intervals

● Stopper designed for the prevention of fracture of the holding part and

occurrence of foreign matter such as blood stain during the surgery

● The laser marking is designed for easy identification during the connection

of fixtures

● Use for removal following fixture grafting and mount separation

Bone Profiler Platform(∅)

∅A Mini Regular Wide T-type

4 ABPM400C - - -

5 ABPM500C ABPR500C - -

6 - ABPR600C ABPW600C TBPW600C

7 - - ABPW700C -

● Use to remove the bone generated around the cover screws during the

second surgery

● After removing the cover screws, connect the guide screw to the fixtures

and use for the angle compensation of the healing abutments

● The guide screw protects the hex of the fixtures

● TiN coating improves anti-corrosion and wear resistance∅A

Page 20: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

39

KIT

38

KIT

OSSTEM IMPLANT SYSTEMM R W Fixture Diameter

Drill

● Direct drill: 2-stepped drill equipped with both pilot and twist drill function

1. Enables final drilling without pilot drilling

2. Enhancement of initial fixation in the extract socket by decreasing

the dead space at the apex area

Surgical Tool for Ultra-Wide�

● Dedicated tool for HG II / III Ultra-Wide fixture

● Use after forming a final direct hole in hard bone

● Used to verify the depth and width of the extraction socket and check the drilling

depth after the final drilling

● Verify the diameter of the interior of the failed implant socket.

● Used to verify the drilling path

Trial Pin

∅4.6 ThreeCutterTwistDrill

∅5.5DirectDrill

∅5.2DirectDrill

∅6.5DirectDrill

∅4

.6×

13

∅5

.2×

13

∅5

.5×

13

∅6

.5×

13

Name D1 D2 Code

∅4.6 Three Cutter Drill ∅4.6 - 3D4613FNLC

∅5.2 Direct Drill ∅4.6 ∅5.2 3D5213FNLC

∅5.5 Direct Drill ∅4.6 ∅5.5 3D5513FNLC

∅6.2 Direct Drill ∅5.5 ∅6.2 3D6213FNLC

∅6.5 Direct Drill ∅5.5 ∅6.5 3D6513FNLC

6 78.5 10

11.5 13

D2

D1

∅6.2DirectDrill

∅6

.2×

13

D1

34

Cortical Drill Name Code

F6.0 Cortical Drill CD4C60

F7.0 Cortical Drill CD4C70

F6

.0

F7

.0

Diameter(D) ∅5.2 ∅5.5 ∅6.2 ∅6.5

Code UWFTP52 UWFTP55 UWFTP62 UWFTP65

∅5.5

Trial Pin

∅6.5

Trial Pin

∅3.0

D

∅2.0

∅6.2

Trial Pin

∅5.2

Trial Pin

6 78.5 10

11.5 13

53

Page 21: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

41

KIT

40

KIT

∅5.0mm Fixture ( Length : 10mm )

Drilling Sequence for GS III / SS III

GS III / SS III Fixture(Straight Drill) GS III / SS III Fixture(Straight Drill)

GS III

GS III SS III

∅3.5mm Fixture ( Length :10mm )

∅4.0mm Fixture ( Length :10mm )

11mm 10mm

1mm∅2.0 Drill Pilot Drill

(2.0/3.0)∅3.0 Drill for 3.5

Cortical Drill 3

∅2.0 � Pilot � ∅3.0 � Fixture --- Soft Bone

C.D.3 (half) � Fixture --- Normal Bone

C.D.3 (full) � Fixture --- Hard Bone

Length:10mmSoft

BoneNormal

BoneHard Bone

BoneCrest

BoneCrest

∅2.0 Drill Pilot Drill(2.0/3.0)

∅3.0 Drill ∅3.3 Drill

∅2.0 � Pilot � ∅3.0 � ∅3.3 Fixture --- Soft Bone

4.0 C.D.3 (half) � Fixture --- Normal Bone

4.0 C.D.3 (full) � Fixture --- Hard Bone

Length:10mm

for 4.0Cortical Drill 3

Soft Bone

Normal Bone

Hard Bone

11mm 10mm

1mm

C.D.3 : Cortical Drill 3 ∅4.5mm Fixture ( Length :10mm )

∅5.0mm Fixture ( Length :10mm )

∅2.0 Drill Pilot Drill(2.0/3.0)

Pilot Drill(3.0/3.8)

∅3.0 Drill ∅3.8 Drill for 4.5Cortical Drill 3

∅2.0 � Pilot � ∅3.0 � Pilot � ∅3.8 � Fixture --- Soft Bone

4.5 C.D.3 (half) � Fixture --- Normal Bone

4.5 C.D.3 (full) � Fixture --- Hard Bone

Length:10mmSoft

BoneNormal

BoneHard Bone

11mm 10mm

1mm

BoneCrest

for 5.0Cortical Drill 3

∅2.0 Drill Pilot Drill(2.0/3.0)

Pilot Drill(3.0/3.8)

∅3.0 Drill ∅3.8 Drill ∅4.3 Drill

∅2.0 � Pilot � ∅3.0 � Pilot � ∅3.8 � ∅4.3 Fixture --- Soft Bone

5.0 C.D.3 (half) � Fixture --- Normal Bone

5.0 C.D.3 (full) � Fixture --- Hard Bone

Length:10mm

Soft Bone

Normal Bone

Hard Bone

11mm 10mm

1mm

BoneCrest

GS III SS III

GS III SS III

C.D.3 : Cortical Drill 3

Page 22: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

43

KIT

42

KIT

∅5.0mm Fixture ( Length : 10mm )GS III / SS III Fixture(Taper Drill) GS III / SS III Fixture(Taper Drill)

∅3.5mm Fixture ( Length :10mm ) D1 Hard Bone D2, D3 Normal Bone D4 Soft Bone

∅4.0mm Fixture ( Length :10mm )

11mm 10mm

1mm∅2.0 Drill ∅3.0 Drill F3.5

Taper Cortical Drill

∅2.0 � ∅3.0 � Fixture --- Soft Bone

3.5 T.D � Fixture --- Normal Bone

3.5 T.D � 3.5 T.C.D (full) � Fixture --- Hard Bone

Length:10mmSoft

BoneNormal

BoneHard Bone

F3.5 Taper Drill

BoneCrest

F4.0 Taper Cortical Drill

∅2.0 Drill

11mm 10mm

1mm

∅2.0 � 3.5 T.D Fixture --- Soft Bone

4.0 T.D � Fixture --- Normal Bone

4.0 T.D � 4.0 T.C.D (full) � Fixture --- Hard Bone

Length:10mmSoft

BoneSoft

BoneNormal

BoneHard Bone

F3.5 Taper Drill

F4.0Taper Drill

BoneCrest

GS III

GS III SS III

T.D.3 : Taper Drill

T.C.D : Taper Cortical Drill

∅4.5mm Fixture ( Length :10mm )

∅5.0mm Fixture ( Length :10mm )

11mm 10mm

1mm∅2.0 Drill

∅2.0 � 3.5 T.D 4.0 T.D � Fixture --- Soft Bone

4.5 T.D � Fixture --- Normal Bone

4.5 T.D � 4.5 T.C.D (full) � Fixture --- Hard Bone

Length:10mm

Soft Bone

Normal Bone

Hard Bone

BoneCrest

F4.5 Taper Drill

F4.5Taper Cortical Drill

F3.5 Taper Drill

F4.0Taper Drill

∅2.0 � 3.5 T.D � 4.5 T.D Fixture --- Soft Bone

5.0 T.D � Fixture --- Normal Bone

5.0 T.D � 5.0 T.C.D (full) � Fixture --- Hard Bone

Length:10mmSoft

BoneNormal

BoneHard Bone

11mm 10mm

1mm

BoneCrest

∅2.0 Drill F5.0 Taper Drill

F5.0Taper Cortical Drill

F3.5 Taper Drill

F4.5Taper Drill

GS III SS III

GS III SS III

T.D.3 : Taper Drill

T.C.D : Taper Cortical Drill

Page 23: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

45

KIT

44

KIT

∅5.0mm Fixture ( Length : 10mm )

Drilling Sequence for GS II

GS II Fixture GS II Fixture

∅3.5mm Fixture ( Length :10mm ) D1 Hard Bone D2, D3 Normal Bone D4 Soft Bone

∅4.0mm Fixture ( Length :10mm )

Normal Bone

Hard Bone

11mm 10mm

1mm ∅2.0 Drill

Soft Bone

∅2.7 Drill Pilot Drill(2.0/3.0)

∅3.0 Drill CorticalDrill 2

GS II

∅2.0 D � ∅2.7 D � Fixture --- Soft Bone

Pilot D � ∅3.0 D � Fixture --- Normal Bone

Pilot D � ∅3.0 D � Cortical Drill 2 � Fixture --- Hard Bone

BoneCrest

BoneCrest

Soft Bone

Normal Bone

Hard Bone

∅2.0 Drill Pilot Drill(2.0/3.0)

∅3.0 Drill ∅3.6 Drill ∅3.3 Drill CorticalDrill 2

11mm 10mm

1mm GS II

∅2.0 D � Pilot D � ∅3.0 D ∅3.3 D � Fixture --- Soft Bone

∅3.6 D � Fixture --- Normal Bone

∅3.6 D � Cortical Drill 2 � Fixture --- Hard Bone

∅4.5mm Fixture ( Length :10mm )

∅5.0mm Fixture ( Length :10mm )

11mm 10mm

1mm ∅2.0 Drill Pilot Drill(2.0/3.0)

Pilot Drill(3.0/3.8)

∅3.0 Drill ∅4.1 Drill ∅3.8 Drill CorticalDrill 2

Soft Bone

Normal Bone

Hard Bone

GS II

∅2.0 D � Pilot D � ∅3.0 D � Pilot D � ∅3.8 D Fixture --- Soft Bone

∅4.1 D � Fixture --- Normal Bone

∅4.1 D � Cortical Drill 2 � Fixture --- Hard Bone

∅2.0 Drill Pilot Drill(2.0/3.0)

Pilot Drill(3.0/3.8)

∅3.0Drill

∅4.3 Drill ∅3.8Drill

∅4.6 Drill CorticalDrill 2

11mm 10mm

1mm

Soft Bone

Normal Bone

Hard Bone

GS II

∅2.0 D � Pilot D � ∅3.0 D � Pilot D � ∅3.8 D ∅4.3 D � Fixture --- Soft Bone

∅4.6 D � Fixture --- Normal Bone

∅4.6 D � Cortical Drill 2 � Fixture --- Hard Bone

BoneCrest

BoneCrest

Page 24: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

47

KIT

∅5.0mm Fixture ( Length : 10mm )

Drilling Sequence for US II

US II Fixture

∅3.3mm Fixture ( Length :10mm )

∅3.75mm Fixture ( Length : 10mm )

US II∅2.0 Drill Pilot Drill(2.0/3.0)

∅3.0 Drill Countersink(optional)

Tap

10mm

1mm

US II

10mm

1mm ∅2.0 Drill Pilot Drill(2.0/2.7)

∅2.7 Drill Countersink (optional)

Tap

Soft Bone

Normal Bone

Hard Bone

Soft Bone

Normal Bone

Hard Bone

D1 Hard Bone D2, D3 Normal Bone D4 Soft Bone

BoneCrest

BoneCrest

46

KIT

Drilling Sequence for SS II

SS II Fixture (One Stage)

∅3.3mm Fixture ( Length : 10mm )

∅4.1mm Fixture ( Length : 10mm )

SS II∅2.0 Drill Pilot Drill

(2.0/3.0)

Pilot Drill

(3.0/3.8)

∅3.0 Drill ∅3.8 Drill ∅4.3 Drill

Countersink (optional)

Tap

10mm

1mm

10mm

1mm ∅3.3 Drill ∅3.0 Drill SS II∅2.0 Drill Pilot Drill(2.0/3.0)

∅3.6 Drill Countersink (optional)

Tap

Soft Bone

Normal Bone

Hard Bone

Soft Bone

Hard Bone

Mini

10mm

1mm ∅2.0 Drill Pilot Drill(2.0/2.7)

∅2.7 Drill Countersink (optional)

Tap

∅4.8mm Fixture ( Length : 10mm )

Normal Bone

Soft Bone

Hard Bone

Normal Bone

D1 Hard Bone D2, D3 Normal Bone D4 Soft Bone

BoneCrest

BoneCrest

BoneCrest

Page 25: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

49

KIT

∅5.0mm Fixture ( Length : 10mm )

Drilling Sequence for US III

US III Fixture

US III∅2.0 Drill Pilot Drill(2.0/3.0)

∅3.0 Drill Shaping Drill Tap

∅4.0mm Fixture ( Length : 10mm )

∅5.0mm Fixture ( Length : 10mm )

US III∅2.0 Drill Pilot Drill(2.0/3.0)

Pilot Drill(3.0/3.8)

∅3.8 Drill ∅3.0 Drill ShapingDrill

Tap

Soft Bone

Normal Bone

Hard Bone

Soft Bone

Normal Bone

Hard Bone

D1 Hard Bone D2, D3 Normal Bone D4 Soft Bone

10mm

1mm

10mm

1mm

BoneCrest

BoneCrest

48

KIT

US II Fixture

∅4.0mm Fixture ( Length : 10mm )

US II∅2.0 Drill Pilot Drill(2.0/3.0)

∅3.0 Drill ∅3.3 Drill Countersink(optional)

Tap

10mm

1mm

Soft Bone

Normal Bone

Hard Bone

BoneCrest

US II∅2.0 Drill Pilot Drill(2.0/3.0)

Pilot Drill(3.0/3.8)

∅3.0 Drill

∅3.8 Drill

∅4.3 Drill

Countersink(optional)

Tap

∅5.0mm Fixture ( Length : 10mm )

Soft Bone

Normal Bone

Hard Bone

10mm

1mm

BoneCrest

Page 26: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach

51

KIT

50

KIT

Drilling Sequence for Ultra-Wide

Ultra-Wide� Fixture

Immediate placement at the extraction socket (∅6.0 Ultra-Wide Fixture, Length : 10mm )

Ultra-Wide� Fixture

Delayed placement in the healed mature bone

Drilling sequence with trephine drill

∅6.0 Ultra-Wide�

Fixture, Length : 10mm

Conventional drilling sequence

∅6.0 Ultra-Wide�

Fixture, Length : 10mm

Immediate replacement of the failed implant (∅6.0 Ultra-Wide Fixture, Length : 10mm )

● Use of a surgical tap recommended in case of hard bone

● Verify the depth after final drilling using a trial pin

● Recommended rpm of Trephine drill : 800~1000rpm

Recommended rpm of drilling : 800~1500rpm

Recommended rpm of tapping : below 20rpm

● Use of a surgical tap recommended in case of hard bone

● Verify the depth after final drilling using a trial pin

● Perform 0.5~1mm sub-crestal placement for normal bone or bone of better quality to minimize bone resorption

● Perform crestal placement for soft bone to secure initial fixation form the cortical bone

● Recommended rpm of Trephine drill : 800~1000rpm

Recommended rpm of drilling : 800~1500rpm

Recommended rpm of tapping : below 20rpm

∅4.2/∅5.0

Trephine drill

∅4.6/∅5.5

Direct drill ∅6.0 Ultra-Wide� fixture

US GS SS

Remove septal bone

with trephine

∅6.0 Ultra-Wide� fixture

US GS SS∅4.2/∅5.0

Trephine drill

∅4.0 failed

fixture

∅4.6/∅5.5

Direct drill

Remove failed fixture

with trephine

∅4.2/∅5.0

Trephine drill

∅4.6/∅5.5

Direct drill

∅5.5 Trial pin

∅6.0 Ultra-Wide� fixture

10mm

1mmUS GS SS

BoneCrest

10mm

1mm∅2.0 drill

2.0/3.0 Pilot drill

∅3.0 drill

∅4.1(∅4.3) drill

∅4.6 drill

∅4.6/∅5.5

Direct drill

∅5.5 Trialpin

∅6.0 Ultra-Wide� fixture

3.0/4.1 Pilot drill

US GS SS

BoneCrest

Page 27: Components SYSTEMIMPLANTOSSTEM KIT - biofisabiofisa.com/downloads/biofisa-kit.pdf · production of USII Approved by the FDA in the US Mar Concluded partnership agreement with KaVo(Kaltenbach