components us system systemimplantosstem - …biofisa.com/downloads/biofisa-us.pdf · production of...

34
US System Fixture and Restorative Components OSSTEM IMPLANT SYSTEM

Upload: buidang

Post on 28-Mar-2018

217 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

US SystemFixture and Restorative

Components

OSSTEMIMPLANTSYSTEM

Page 2: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

US System

Contents | OSSTEM IMPLANT

32

24US II RBM

Fixture

26US III RBM

Fixture

28US Ultra

Wide�

Fixture

30Cover Screw

30Headless

Cover Screw

31Healing

Abutment

34Cement

Abutment

36Angled

Abutment

39UCLA Gold

Abutment

41UCLA Plastic

Abutment

37ZioCera

Abutment

43UCLA

Temporary

Abutment

45Fixture

Transfer

Impression

Coping

50Fixture

Lab Analog

50UCLA

Polishing

Protector

51ER

Abutment

52Safe

Abutment

53Esthetic

Abutment

53Esthetic

Healing Cap

54Esthetic

Gold Cylinder

54Esthetic

Plastic

Cylinder

55Esthetic

Transfer

Impression

Coping

55Esthetic

Pick-up

Impression

Coping

54Esthetic

Temporary

Cylinder

55Esthetic

Lab Analog

55Esthetic

Polishing

Protector

56Esthetic-low

Healing Cap

57Esthetic-low

Gold Cylinder

56Esthetic-low

Abutment

57Esthetic-low

Plastic

Cylinder

58Esthetic-low

Temporary

Cylinder

58Esthetic-low

Transfer

Impression

Coping

59Esthetic-low

Lab Analog

59Esthetic-Low

Pick-up

Impression

Coping

59Esthetic-low

Polishing

Protector

60Standard

Abutment

60Standard

Healing Cap

60Standard

Gold Cylinder

61Standard

Plastic

Cylinder

61Standard

Temporary

Cylinder

62Standard

Polishing

Protector

62Standard

Lab Analog

62Standard

Pick-up

Impression

Coping

61Standard

Transfer

Impression

Coping

63O-ring

Abutment

Set

(O-ring Set)

64O-ring

Retainer

Cap Set

64O-ring

Retainer Set

65O-ring Set

65O-ring

Lab Analog

63O-ring

Abutment Set

(Dalbo Set)

63O-ring

Abutment

49Fixture

Pick-up

Impression

Coping - Short

66LOCATOR

Abutment

66LOCATOR

Extened

Replacement

Male

67LOCATOR

Impression

Coping

67LOCATOR

Lab Analog

67LOCATOR

Core Tool

67LOCATOR

Torque Driver

66LOCATOR

Male Processing

Kit

66LOCATOR

Black

Processing

Male

66LOCATOR

Black

Processing

Male

67LOCATOR

Black out

Spacer

47Fixture

Pick-up

Impression

Coping- Long

30Simple Mount

Page 3: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

4 5

US

Sys

tem

US

Sys

tem

OSSTEM IMPLANT R&D Center

Universities/Other

Research InstitutesEducational-industrial projects

GovernmentResearch cooperation with

governmental projects

Customer ClinicsFeed Backs/opinions

Associated Clinical Hospital

Joint clinical research works

OSSTEM IMPLANT

R&D Center

OSSTEM IMPLANT

●Market Share & Brand Recognition NO. 1 In Korean Market

●World Class Product Quality(FDA, CE, ISO9001)

●Enhanced Research & Development Through Impant R&D Center

● Independent Models Development and Production(SSII, GSII)

●A Wide Range of Products with Excellent Compatibility

●Most Advanced Facilities with the Largest Production Capacity in Asia

●Export to the worldwide

●Future Expansion Plan To Over 100 Countries For The Next Five Years

●Active Systematic Impant Clinical Training Through AIC Center

OSSTEM IMPLANT R&D Center

OSSTEM R&D Center consists of 25 professionals who

have doctral/master’s degree in each field.

OSSTEM keeps investing in research and development

area with high tech equipment.

OSSTEM also cooperates with government agencies,

universities, and hospitals in many projects and in-depth

studies.

OSSTEM HISTORY

May Developed and commenced the commercial production of GSII

Apr "OSSTEM MEETING 2005" held in Seoul

(2,700 attendees)

Mar Certified KGMP(Korean Good Manufacturing Practice) in Korea

Published the "2005 OSSTEM IMPLANT SYSTEM (Introduction)"

Jan Established the subsidiary office in Taiwan(Taipei)

Nov Developed and commenced the commercial production of SSIII

Jul Developed and commenced the commercial production of USIII

Apr "OSSTEM MEETING 2004" held in Seoul (1,200 attendees)

Nov Developed and applied its own automatic cleaning system

Jul Established the OSSTEM Information System R&D Center

Oct Developed and commenced the commercial

production of SSII

Aug Developed and commenced the commercial

production of USII Approved by the FDA in the US

Mar Concluded partnership agreement with KaVo(Kaltenbach & Voigt)

Jan Established the OSSTEM Implant R&D Center

Mar Established the AIC

(Apsun Dental Implant Research & Education Center)

Jan CE-0434 Mark certified

Oct Certified ISO-9001

Dec Commenced the commercial production

(brand name : OSSTEM)

Jan Established the Company in Korea

(OSSTEM Co., Ltd.)

Developed the implant and acquired an industrial license

Launched the development of dental implant system

2009

2007

2005

2008

2006

2005

2003

2001

1997

1992

2004

2002

1999

1995

Oct Approved by the Ministry of Health, Labour and Welfare in Japan

Aug ‘2009 OSSTEM MEETING Hong Kong’ held

Oct '2008 OSSTEM MEETING Singapore' held

Aug '2008 OSSTEM MEETING Hong Kong' held

Jul '2008 OSSTEM MEETING Taiwan' held in Taipei

Jun Development and sales of GSIII implant

Apr '2008 AIC World Meeting' held in Seoul

Mar Established ATC training center

'2008 OSSTEM MEETING Thailand' held in Bangkok

Jan Established OSSTEM Bone Science Institute

Nov ‘2007 OSSTEM MEETING Malaysia’ held in Kuala Lumpur

‘2007 OSSTEM MEETING USA’ held in Los Angeles

Oct ‘2007 OSSTEM MEETING India’ held in Mumbai

‘2007 OSSTEM MEETING Russia’ held in Moscow

Established the incorporate subsidiary in Australia(Sydney)

Sep ‘2007 OSSTEM MEETING Hong Kong’ held

‘2007 OSSTEM MEETING Singapore’ held

Jul ‘2007 OSSTEM MEETING Taiwan’ held in Taipei

Jun Approved by the TGA in Australia

May KFDA approved OSSTEM tissue bank foundation

Apr Published "2006 OSSTEM IMPLANT SYSTEM" in English Version

"OSSTEM MEETING 2007" held in Seoul (12,000 attended)

Feb Listed on KOSDAQ (KRX : Korea Exchange)

Dec Established the subsidiary offices in

Thailand(Bangkok), and Malaysia(Kuala Lumpur)

Nov Approved by the SFDA in China

Sep Established the U.S Corporate Headquarter and started

construction of manufacturing facility in the US

Aug Established the subsidiary offices in

China(Beijing), Hongkong, and Singapore

Jul Established the subsidiary office in Japan(Tokyo)

Apr Certified GOST-R in Russia

"OSSTEM MEETING 2006" held in Seoul

(6,500 attendees) Published the "2006 OSSTEM IMPLANT SYSTEM

(introduction and particulars of implant system)"

Jan Established the subsidiary offices in India(Mumbai)

and Russia(Moscow)

Dec Completed, relocated new production plant in Busan

Established the subsidiary office in Germany(Ashborn)

Approved by the DOH in Taiwan

Page 4: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

7

US

Sys

tem

6

US

Sys

tem

CHARACTERISTIC of OSSTEM IMPLANT SYSTEM

Evaluation of Sinus Bone Resorption and Marginal Bone Loss after

Sinus Bone Grafting and Implant PlacementYoung-Kyun Kim et al.

No. Title Reference Author

■US System- Clinic

1

Evaluation of Periimplant Tissue Response according to the

Presence of Keratinized Mucosa

Oral Surg Oral Med Oral Pathol OralRadiol Endod

2009;107:e24-8

Oral Surg Oral Med Oral Pathol Oral Radiol Endod

2009;107:e21-8

Young-Kyun Kim et al.2

Correlation Between Bone Quality Evaluated by Cone-Beam

Computerized Tomography and Implant Primary StabilityInt J Oral Maxillofac Implants 2009;24(1):59-64 Jong-Jin Kwon et al.3

Clinical and Radiographic Evaluation of Implants with

Dualmicrothread:1-year StudyJ Korean Acad Periodontol 2009;39(1):27-36 Ju-Youn Lee et al.4

Bone Density and Histomorphometry Assessment ofDental Implant

Using Computerized Tomography

J Korean Assoc Maxillofac Plast Reconstr Surg

2009;31(2):137-46Yeong-Cheol Cho et al.5

Implant Replacement Utilizing Zirconia Abutment in EstheticZone J Korean Implantology(KAOMI) 2009;13(2):16-24 Sok-Min Ko et al.6

A Retrospective Study on the Clinical Success Rate of

OsstemImplantKey Engineering Materials 2008;361-363:1331-4 Su-Kwan Kim et al.7

Multicenter Retrospective Study of Immediate Two Different RBM

Surfaced Implant Systems after Extraction

J Korean Assoc MaxillofacPlast Reconstr Surg

2008;30(3):258-65Hee-Kyun Oh et al.8

A Retrospective Multicenter Clinical Study of Installed US II / SS II

Implants after Maxillary Sinus Floor ElevationJ Kor Oral Maxillofac Surg 2008;34:341-9 Hee-Kyun Oh et al.9

Clinical Retrospective Study of Sinus Bone Graft and Implant

Placement

J Korean Assoc Maxillofac Plast ReconstrSurg

2008;30(3):294-302Young-Kyun Kim et al.10

A Retrospective Evaluation of Implant Installation with Maxillary

Sinus Augmentation by Lateral Window Technique

J Korean Assoc Maxillofac Plast Reconstr Surg

2008;30(5):457-64Hee-Kyun Oh et al.11

Short term Retrospective Clinical Study on GS II, SS III, US III J Korean Implantology(KAOMI) 2008;12(2):12-22 Young-Kyun Kim et al.12

Multicenter Retrospective Clinical Study of Osstem US II

ImplantSystem in Type IV BoneJ Korean Implantology(KAOMI) 2007;11(3):22-9 Su-Kwan Kim et al.13

Multicenter Retrospective Clinical Study of Osstem US II

ImplantSystem in Complete Edentulous PatientsJ Korean Implantology(KAOMI) 2007;11(3):12-21 Su-Kwan Kim et al.14

Retrospective Multicenter Cohort Study of the Clinical Performance

of 2-stage Implants in South Korean PopulationsInt J Oral & Maxillofac Implants 2006;21(5):785-8 Seok-Min Ko et al.15

Analysis of Clinical Application of Osstem (Korea) Implant System

for 6 YearsJ Korean Implantology(KAOMI) 2006;10(1):56-65 Young-Kyun Kim et al.16

Multicentric Prospective Clinical Study of KoreanImplant System:

Early Stability Measured by PeriotestJ Korean Dent Assoc 2004;42(12):873-81 Young-Kyun Kim et al.17

A Comparative Study of Two Noninvasive Techniques to Evaluate

Implant Stability: Periotest and Osstell MentorSu-Gwan Kim et al.

No. Title Reference Author

■US System- Biology

1

Effects of Different Depths of Gap on Healing of Surgically Created

Coronal Defects around Implants in Dogs: A Pilot StudyJ Periodontol 2008;79(2):355-61

Oral Surg Oral Med Oral Pathol Oral Radiol Endod

2009;107:513-8

June-Sung Shim et al.2

Histologic and Histomorphometric Evaluation of Early and

Immediately Loaded Implants in the Dog MandibleJ Biomed Mater Res 2008;86A:1122-7 Su-Gwan Kim et al.3

The Effect of Surface Treatment of the Cervical Area of Implant on

Bone Regeneration in Mini-pigJ Kor Oral Maxillofac Surg 2008;34:285-92 Hong-Ju Park et al.4

Comparative Study of Removal Effect on Artificial Plaque from RBM

Treated Implant

J Korean Assoc Maxillofac Plast Reconstr Surg

2007;29(4):309-20Hee-Jyun Oh et al.5

Comparative Study of Osseointegration of 4 Different Surfaced

Implants in the Tibia of DogsJ Kor Oral Maxillofac Surg 2005;31:46-54 Hee-Jyun Oh et al.6

Effect of Implant Surface Characteristics on Osseointegration in the

Ilium of Dogs

J Korean Assoc Maxillofac Plast Reconstr Surg

2004;36(6):531-41Hee-Jyun Oh et al.7

Effect of Tightening Torque on Abutment-Fixture Joint Stability

using 3-Dimensional Finite Element AnalysisChang-Mo Jeong et al.

No. Title Reference Author

■US System- Biomechanics

3

Screw Joint Stability under Cyclic Loading of Zirconia Implant

AbutmentsJ Kor Acad Prosthodont 2009;47(2):164-73

J Kor Acad Prosthodont 2009;47(2):125-35

Jae-Jun Ryu et al.4

Heat Transfer to the Implant-Bone Interface during preparation of

Zirconia/Alumina Complex AbutmentYong-Geun Choi et al.1

Fatigue Fracture of Different Dental Implant System under Cyclic

LoadingJ Kor Acad Prosthodont 2009;47(4):424-34

Int J Oral Maxillofac Implants 2009;24(4):679-83

In-ho Cho et al.2

Influence of Tightening Torque on Implant-Abutment Screw Joint

StabilityJ Kor Acad Prosthodont 2008;46(4):396-408 Chang-Mo Jeong et al.5

Influence of Tungsten Carbide/Carbon Coating of Implant-

Abutment Screw on Screw LooseningJ Kor Acad Prosthodont 2008;46(2):137-47 Chang-Mo Jeong et al.6

The Assessment of Abutment Screw Stability Between the External

and Internal Hexagonal Joint under Cyclic LoadingJ Kor Acad Prosthodont 2008;46(6):561-8 Jung-Suk Han et al.7

Influence of Implant Fixture Design on Implant Primary Stability J Kor Acad Prosthodont 2006;45(1):98-106 Seok-Gyu Kim et al.8

An Influence of Abutment Materials on a Screw-Loosening after

Cyclic LoadingJ Kor Acad Prosthodont 2007;45(2):240-249 Jung-Suk Han et al.9

Influence of Tungsten Carbide/Carbon on the Preload of Implant

Abutment ScrewsJ Kor Acad Prosthodont 2006;44(2):229-42 Chang-Mo Jeong et al.10

The Effect of Internal Implant-Abutment Connection and Diameter

on Screw LooseningJ Kor Acad Prosthodont 2005;43(3):379-92 Kyung-Soo Jang et al.11

Wave Analysis of Implant Screw Loosening using an Air Cylindrical

Cyclic Loading DeviceJ Prosthet Dent 2002;88:402-8 Jung-Suk Han et al.12

The Comparative Study of Mechnical Stability Between Self Tapping

Fixture and Double Threaded Fixture by 3-dimensional Finite

Element Analysis

J Kor Acad of General Dentistry 1999;1(1):73-81 Byung-nam Hwang et al.14

Preliminary Study on the Design of Screw Head for Rapid Fastening

& LooseningJ Kor Acad Family Medcine 2000;2(2):26-31 Jae-Bong Lee13

Page 5: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

8 9

CHARACTERISTIC of OSSTEM IMPLANT SYSTEM

Reliable implant that has acquired various international quality certifications (FDA, CE, ISO9001, etc.)

Various product lines that can be optimized according to the oral cavity and surgical situation

● Submerged type implant with an external hex connection

structure

● All RBM surface treatment (US plus) improves compatibility

between bone and soft tissue

● Can facilitate placement applicable to various bone quality

and obtain superior bonding stability

● Product line: USII, USIII, US Ultra Wide�

RBM

US System

OSSTEM Implant System Flow

● Hex 3.4mm external connection● Compatible with US wide abutment● Wide diameter fixture● Indication of US Ultra-Wide system

- Immediate placement at the extract socket

- Immediate replacement of the failed implant

● Increased osseointegration in the cortical bone● Expanded contact area with the bone● Decreased marginal bone loss● RBM surface treated for excellent

biocompatibility

● Increased osseointegration in the cortical bone● Expanded contact area with the bone● Decreased marginal bone loss● RBM surface treated for excellent

biocompatibility

US II US III

L: 8.5 10 11.5 13 15

US Ultra Wide�

L : 7 8.5 10 11.5 13 15

L: 8.5 10 11.5 13 15

L : 7 8.5 10 11.5 13 15

L : 7 8.5 10 11.5 13 15L : 7 8.5 10 11.5 13 15 L : 7 8.5 10 11.5 13

6.0

US

Sys

tem

US

Sys

tem

Hex Type

Abutment Diameter

Fixture Diameter

H

G / H

L

Page 6: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

10 11

US

Sys

tem

US

Sys

tem

Torque Driver Extened Replacement Male

US Prothesis Library

System

UCLA

Cement

ER

ZioCera

Angled

Safe

Abutment

Esthetic

Esthetic-low

Standard

O - ring

Abutment Abutment Screw Impression Coping Lab Analog Temporary Abutment & Cylinder Polishing Protector

(Non-Hex)(Hex) (Hex)

(Non-Hex)(Hex)

Cement

(Ti)

(Ti)

(Ti)

(Ti)

ERZioCera/

ZioCera Angled

(Double Hex)(15°) (25°)

Angled

(Gold)

Abutment Protect Cap

Healing Cap

Gold Cylinder

O-rings System Dalbo System

Cylinder Screw

(Hex) (Non-Hex)

(Hex) (Non-Hex)

(Hex) (Non-Hex)

(Hex) (Non-Hex)

(Hex) (Non-Hex)

(Hex) (Non-Hex)

Pick-up

Transfer

Plastic Cylinder

(Non-Hex)(Hex)

(Plastic)

(Hex)

Pick-up Transfer

Transfer

Transfer

(Hex) (Non-Hex)

(Hex) (Non-Hex)

(Hex) (Non-Hex)

(Only UCLA Abutment)

Pick-up

(Non-Hex)

(Hex) (Non-Hex)

OSSTEM

US System

Cover Screw Headless Cover Screw Healing Abutment US II Fixture US III Fixture US Ultra-Wide�

LOCATOR

Pick-up

Replacement Male Extened Replacement Male

Page 7: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

13

US

Sys

tem

12

US

Sys

tem

OS

MS

Ortho KIT(OOKS)

MS KIT(OMSK)

Guide Drill

Sidecut Drill

Parallel Pin

Hand Driver

Torque Driver SS Fixture

Driver

GS Fixture

Driver

No Mount

Driver

Removal Tool

for Mount

Drill Extension

Simple Open WrenchCortical Drill 3 Ratchet Wrench Depth Gauge

Long Shank Pilot Drill

US Long Shank

Countersink

SS Long Shank

Countersink

SS II Surgical TapUS II Surgical Tap

Simple Mount Extension

Simple Mount DriverTwist Drill

Cortical Drill 2

Surgical

US

SS

IIHanaro KIT(HKA2), Simple KIT(OSPK) Prosthetic KIT

(OPK)

Ridge Split KIT

(ORSSK/ORSOK)

Osteotome KIT(AOST)

Osteo KIT(OSTK)

Sinus KIT(ASLK)

Bone Spreader KIT

(OBSOK)

Prosthetic Etc

KIT for each system

IIIHanaro KIT(HKA2), Simple KIT(OSPK)

Taper KIT(OTSK), Taper Mini KIT(OGS3MK)

Ultra

II

III

Ultra

Ultra KIT(OUK)

Hanaro KIT(HKA2), Simple KIT(OSPK)

Hanaro KIT(HKA2), Simple KIT(OSPK)

Taper KIT(OTSK), Taper Mini KIT(OGS3MK)

Ultra KIT(OUK)

Surgical

GS

IIGS KIT(OGSK2), GS Mini KIT(OIKGM)

Hanaro KIT(HKA2)

Prosthetic KIT

(OPK)

GS Prosthetic

KIT(GSPK)

Ridge Split KIT

(ORSSK/ORSOK)

Osteotome KIT(AOST)

Osteo KIT(OSTK)

Sinus KIT(ASLK)

Bone Spreader KIT

(OBSOK)

Prosthetic Etc

KIT for each system

IIITaper KIT(OTSK), Taper Mini KIT(OGS3MK)

GS KIT(OGSK2), GS Mini KIT(OIKGM), Hanaro KIT(HKA2)

Ultra Ultra KIT(OUK)

Page 8: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

OSSTEMIMPLANTSYSTEMUS SystemFixture and RestorativeComponents Early & Esthetic

OSSTEM IMPLANT

US System

Page 9: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

17

US

Sys

tem

16

US

Sys

tem

Prosthetic Flow Diagrams for US SystemCement Retained Restoration : Cement Abutment, Angled Abutment, ZioCera, UCLA Abutment

Screw Retained Retoration : UCLA Abutment, ZioCera/ZioCera Angled Abutment

Screw & Cement Retained Restoration : ER Abutment ● Mini, Regular, Wide

Ti Screw

Polishing Protector

(Only UCLA Abutment)

1.2 Hex Driver(Mini Only : 0.9Hex Driver)

Cover Screw Healing Abutment 1.2 Hex Driver

ER AbutmentCement Abutment

(Short) (Long)

Fixture Pick-up Impression Coping

Fixture Transfer Impression Coping

(Double Hex) (Hex)

Angled Abutment

(Non-Hex)

UCLA Gold Abutment(Hex) (Non-Hex)(Hex)

(Non-Hex)(Hex)

(Non-Hex)(Hex)(Non-Hex)(Hex)Temporary AbutmentUCLA Plastic Abutment

Fixture Lab Analog

ZioCera/ZioCera

Angled Abutment

Fixture Lab Analog

Safe Abutment

1.2 Hex Driver(Mini Only : 0.9Hex Driver)

Cover Screw Healing Abutment 1.2 Hex Driver

(Short) (Long)

Fixture Pick-up Impression Coping

Fixture Transfer Impression Coping

(Non-Hex)(Hex)

Prosthetic Flow Diagrams for US SystemCement Retained Restortion : Safe Abutment ●Regular, Wide

Carrier Cap Protect Cap

34p36p

38p37p

50p

47p

30p

31p

47p 45p

50p

52p

52p 52p

30p31p

45p

50p

41p

51p

43p

26p 28p

US Ultra-Wide�

24p

US II US III

26p 28p

US Ultra-Wide�

24p

US II US III

Page 10: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

19

US

Sys

tem

18

US

Sys

tem

Prosthetic Flow Diagrams for US SystemScrew Retained Restoration : Esthetic Abutment ● Regular

Esthetic

Polishing Protector

Esthetic

Lab Analog

Ti Screw

2.0 int. Hex Driver (Regular)

1.2 Hex Driver(Mini Only : 0.9Hex Driver)

Cover Screw Healing Abutment

1.2 Hex Driver

Esthetic Abutment Screw

Esthetic Abutment(Regular Only)

Esthetic Healing Cap

Prosthetic Flow Diagrams for US SystemScrew Retained Restoration : Esthetic-low Abutment ●Regular, Wide

Esthetic - low

Ti Screw

Cover Screw Healing Abutment

2.0 int.Hex Driver (Regular)

2.7 int.Hex Driver (Wide)

1.2 Hex Driver(Mini Only : 0.9Hex Driver)

1.2 Hex Driver

Esthetic-low Abutment Esthetic-low Healing Cap

Esthetic-low Transfer

Impression Coping

Esthetic-low

Polishing Protector

Esthetic-low

Lab Analog

Esthetic-low Abutment Screw

Esthetic

Temporary Cylinder

Esthetic Pick-up

Impression Coping

Esthetic

Transfer

Impression Coping

Esthetic Gold Cylinder Esthetic Plastic Cylinder Esthetic-low

Temporary Cylinder

Esthetic-low

Gold Cylinder

Esthetic-low

Plastic Cylinder

(Non-Hex)(Hex)

(Non-Hex) (Non-Hex)(Hex)(Hex)

(Non-Hex)(Hex) (Non-Hex)(Hex) (Non-Hex)(Hex) (Non-Hex)(Hex) (Non-Hex)(Hex)

Esthetic - low Pick-up

Impression Coping

54p

55p

55p

53p

30p31p

53p

55p

55p

58p

59p

59p

56p

30p31p

56p

58p

59p

57p 57p54p 54p

26p 28p

US Ultra-Wide�

24p

US II US III

26p 28p

US Ultra-Wide�

24p

US II US III

Page 11: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

21

US

Sys

tem

20

US

Sys

tem

Prosthetic Flow Diagrams for US SystemScrew Retained Restoration : Standard Abutment ● Regular

Standard Temporary Cylinder

Standard

Polishing Protector Standard Lab Analog

Standard Gold Cylinder Standard Plastic Cylinder

Ti Screw

2.0 int.Hex Driver

1.2 Hex Driver(Mini Only : 0.9Hex Driver)

Cover Screw Healing Abutment

1.2 Hex Driver

Standard Abutment Screw

Standard Abutment(Regular Only)

Standard Healing Cap

Standard Pick-up

Impression Coping

Standard Transfer

Impression Coping

61p

62p

62p

61p

60p 60p

31p30p

62p

60p 61p

Prosthetic Flow Diagrams for US SystemOverdenture Restoration : O-ring / LOCATOR Abutment ●Regular

Cover Screw1.2 Hex Driver(Mini Only : 0.9Hex Driver)

1.2 Hex DriverHealing Abutment

30p 31p

O-ring Lab Analog LOCATOR Impression Coping

LOCATOR Lab Analog

O-ring Abutment Driver

(Low Retention)

(High Retention)

O-rings Retainer

Dalbo Plus Attachment

(for Laboratory)

(for Denture)

(Cap Type)

(Open Type)

O-ring System

Dalbo plus Screw Driver

Dalbo System

Block out Spacer & Denture Cap

Replacement Male Extended Replacement Male

Core Tool

Stud Abutment LOCATOR Abutment LOCATOR Torque Driver

64p

63p

63p

65p

63p

66p

67p

67p

67p

66p

66p 67p

26p24p

US II US III

26p24p

US II US III

Page 12: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

22

US

Sys

tem

23

US

Sys

tem

● External hex-connected, submerged fixture

● Triple-tapered thread and double-tapered shape enable excellent initial bonding stability with soft bone

● Excellent precision fit with superstructure denture : looseness between fixture hex and

superstructure 7-15 , rotation looseness 0.4 -2

●Natural root-like shape enables immediate insertion upon extraction

● Tapered body shape minimizing damage to adjacent roots

● 3-bladed cutting edge with excellent self-tapping force

●Hybrid RBM surface facilitating plaque control

● A variety of diameters and lengths are available for various oral environments

● Limited insertion torque : 40Ncm

* We recommend that the fixture with over 4.5mm diameter is used for single case in Molar

Mini Platform ∅3.5

8.5 10 11.5 13 15

US II Fixture

Regular Platform ∅4.1

Wide Platform ∅5.1Features of US II Fixture

8.57.0 10 11.5 13 15

P ∅3.5

Hex 2.4

L D ∅3.3

7.0 -

8.5 BFM208A

10 BFM210A

11.5 BFM211A

13 BFM213A

15 BFM215A

P ∅4.1

Hex 2.7

L D ∅3.75 ∅4.0

7.0 BFR307A BFR407A

8.5 BFR308A BFR408A

10 BFR310A BFR410A

11.5 BFR311A BFR411A

13 BFR313A BFR413A

15 BFR315A BFR415A

P ∅5.1

Hex 3.4

L D ∅5.0 ∅5.5

7.0 BFW507A BFW607A

8.5 BFW508A BFW608A

10 BFW510A BFW610A

11.5 BFW511A BFW611A

13 BFW513A BFW613A

15 BFW515A BFW615A

8.57.0 10 11.5 13 15

Hex 1.2

Hex : 0.9 for Mini

1.2 for Regular & Wide

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

L

D

D

P

P

L

D

P

L

US II Fixture Order Code

Fixture Only

-Fixture : Product Code (ex : BFR307A)

Pre-Mounted Fixture (Simple Mount)

-Fixture + Simple Mount + Cover Screw : A + Fixture Product Code (ex : ABFR307A)

LRBM

D

Hex 2.4

Hex 2.7

Hex 3.4

※ The following labeled dimension may differ from the actual dimension.

Page 13: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

24

US

Sys

tem

25

US

Sys

tem

※ The following labeled dimension may differ from the actual dimension.

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

● External hex-connected, submerged fixture

● Excellent precision fit with superstructure denture : looseness between fixture hex and

superstructure 7-15 , rotation looseness 0.4 -2

● Taper body offers excellent primary bonding

● Corkscrew thread & Cutting edge

- Powerful self threading

- Change path easily

- Increase insertion torque in soft bone

- Increase initial stability in soft bone

● A variety of diameters and lengths are available for various oral environments

● Limited insertion torque : 40Ncm

* We recommend that the fixture with over 4.5mm diameter is used for single case in Molar

US III Fixture

Features of US III Fixture

Hex 1.2

US III Fixture Order Code

Fixture Only

-Fixture : Product Code (ex : US3R4010R)

Pre-Mounted Fixture (Simple Mount)

-Fixture + Simple Mount + Cover Screw : A + Fixture Product Code (ex : AUS3R4010R)

L

Hex : 1.2 for Regular & Wide

D

Mini Platform ∅3.5

8.5 10 11.5 13 15

P ∅3.5

Hex 2.4

L D ∅3.5

7.0 -

8.5 US3M3508R

10 US3M3510R

11.5 US3M3511R

13 US3M3513R

15 US3M3515RD

L

Hex 2.4P

Regular Platform ∅4.1 P ∅4.1

Hex 2.7

L D ∅4.0 ∅4.5

7 US3R4007R US3R4507R

8.5 US3R4008R US3R4508R

10 US3R4010R US3R4510R

11.5 US3R4011R US3R4511R

13 US3R4013R US3R4513R

15 US3R4015R US3R4515R

P

L

Hex 2.7

Wide Platform ∅5.1 P ∅5.1

Hex 3.4

L D ∅5.0

7 US3W5007R

8.5 US3W5008R

10 US3W5010R

11.5 US3W5011R

13 US3W5013R

15 US3W5015R

8.57.0 10 11.5 13 15

8.57.0 10 11.5 13 15

L

Hex 3.4

Hex 2.7

Wide PS Platform ∅5.0 P ∅5.0

Hex 2.7

L D ∅4.5 ∅5.0

7 US3P4507R US3P5007R

8.5 US3P4508R US3P5008R

10 US3P4510R US3P5010R

11.5 US3P4511R US3P5011R

13 US3P4513R US3P5013P

15 US3P4515R US3P5015R

L

P

P

8.57.0 10 11.5 13 15

D

D

D

Page 14: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

27

US

Sys

tem

26

US

Sys

tem

● External hex, wide-diameter fixture that commonly uses US wide abutment components

● A fixture that is convenient to use in case of immediate insertion following posterior tooth

extract socket and replacement of failed implants

● Looseness between fixture hex and superstructure : 7~15 Rotation looseness : 0.4°~ 2°

● Securing a platform switching effect that minimizes bone resorption and enhances soft tissue volume

● Optimized apex design that enables gaining stable initial fixation even at 3 mm below the extract socket

● All RBM surfaces with excellent bio-affinity

● 4-bladed cutting edge with excellent self-tapping force

● A variety of diameters and lengths are available for various oral environments

● Limited insertion torque : 40 Ncm

Platform ∅6.0

Hex 3.4

L D ∅7.0

7.0 BFW7007A

8.5 BFW7008A

10 BFW7010A

11.5 BFW7011A

13 BFW7013A

US Ultra-Wide� Fixture

Wide Diameter ∅6.0

Features of US Ultra-Wide fixture

( *Uses the same mount and cover screw with US Wide )

7.0 8.5 10 11.5 13

OSSTEM IMPLANT SYSTEMW Fixture Platform

L

D

US Ultra-Wide� Fixture Order Code

Fixture Only

- Fixture : Product Code (ex : BFW6008A)

Pre-Mounted Fixture (Simple Mount)

- Fixture + Simple Mount + Cover Screw : A + Fixture Product Code (ex : ABFW6008A)

Wide Diameter ∅7.0

7.0 8.5 10 11.5 13

L

D

Hex : 1.2

Hex : 1.2

1.2

Platform ∅5.1

Hex 3.4

L D ∅6.0

7.0 BFW6007A

8.5 BFW6008A

10 BFW6010A

11.5 BFW6011A

13 BFW6013A

D

RBM

※ The following labeled dimension may differ from the actual dimension.

Page 15: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

29

US

Sys

tem

28

US

Sys

tem

Headless Cover Screw

Healing AbutmentMini Regular Wide

Code ESFMM ESFMR ESFMW

● Color indication facilitates the identification in the oral cavity

●Use a 1.2 hex driver to remove screws

● Packing unit : Mount + Mount Screw

● Tightening torque : 8-10 Ncm

●Use a 1.2 hex driver

● Packing unit : Healing abutment

● Tightening torque : 5-8 Ncm

●Use 0.9 (mini) and 1.2 (regular and wide) hex drivers

● Packing unit : Cover Screw

● Tightening torque : 5-8 Ncm

Mini Regular Wide

US HCM100 HCR100 HCW100

●Use for limited proximal space or suturing with deficient gingiva

●Use 0.9 (mini) and 1.2 (regular and wide) hex drivers

● Packing unit : Headless cover screw

● Tightening torque : 5-8 Ncm

Mini Regular Wide

Simple Mount

LD ∅6.0

2.0 -

3.0 TIHW603

4.0 -

5.5 TIHW605

7.0 -

LD ∅4.1 ∅5.0 ∅6.0

2.0 - AIHR502 AIHR602

3.0 AIHR403 AIHR503 AIHR603

4.0 - AIHR504 AIHR604

5.5 AIHR405 AIHR505 AIHR605

7.0 AIHR407 AIHR507 AIHR607

0.9 1.2

WideRegularMini

L

1.2

Regular

Wide PS

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

D

1.2

L

1.2

1.2

L

1.21.21.2

8.0

∅5.0∅4.1 ∅6.0

∅6.0

DD

Mini Regular Wide Wide PS

US AICM100 AICR100 AICW100 TICW100

Cover Screw

1.1 1.1 1.1

Mini Regular Wide

0.9 1.2 1.2

1.1

Wide PS

1.2

H D ∅4.0 ∅5.0

2.0 - -

3.0 AIHM403 AIHM503

4.0 - -

5.5 AIHM405 AIHM505

7.0 - -

Mini

1.2

∅4.0

H

1.2

D

1.1

∅5.0

H D ∅5.1 ∅6.0 ∅7.0

2.0 - AIHW602 AIHW702

3.0 AIHW503 AIHW603 AIHW703

4.0 - AIHW604 AIHW704

5.5 AIHW505 AIHW605 AIHW705

7.0 - - -

1.2

Wide

H

1.2

1.2

∅5.1 ∅6.0 ∅7.0

H

D

1.2

D

Page 16: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

OSSTEM Implant SystemEarly & Esthetic OSSTEM IMPLANT

US SystemComponents Guide

ER

Cement

Angled

Safe

Esthetic

Esthetic-low

Standard

O-ring LOCATOR�

UCLA

Standard Cylinder

Esthetic Cylinder

Esthetic-low Cylinder

ZioCera

ZioCera Angled

Page 17: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

33

US

Sys

tem

32

US

Sys

tem

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

●Use for making general cement-type prosthesis

● Gigival gold color for aesthetic effect

● Tapered body design facilitating prosthetic fit

● Cross-section design for the prevention of prosthesis rotation

●Use a 1.2 hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : Ti screw : 30Ncm

EbonyGold screw : 20Ncm(mini), 30Ncm(regular & wide)

Order code - Abutment + Ti screw : Product code + TH (ex : CAR525TH)

Mini

WIde

(∅6.0)

(∅7.0)

Wide PSRegularRegular

(∅5.0)

(∅6.0)

Cement Abutment - Cement Retained Restoration

D ∅4.0

H G/HType

Hex Non-Hex

1.0 - -

7.02.0 CAM427 CAM427N

3.0 - -

4.0 CAM447 CAM447N

Ti

EbonyGoldScrew

ASM200*

ASM200W

D ∅5.0 ∅6.0

H G/HType Hex Non-Hex Hex Non-Hex

1.0 CAR514 CAR514N - -

4.02.0 CAR524 CAR524N - -

3.0 CAR534 CAR534N - -

4.0 CAR544 CAR544N - -

1.0 CAR515 CAR515N CAR615 CAR615N

5.52.0 CAR525 CAR525N CAR625 CAR625N

3.0 CAR535 CAR535N CAR635 CAR635N

4.0 CAR545 CAR545N CAR645 CAR645N

1.0 CAR517 CAR517N - -

7.02.0 CAR527 CAR527N - -

3.0 CAR537 CAR537N - -

4.0 CAR547 CAR547N - -

ASW200*

ASW200W

D ∅6.0 ∅7.0

H G/HType

Hex Non-Hex Hex Non-Hex

1.0 CAW614 CAW614N - -

4.02.0 CAW624 CAW624N - -

3.0 CAW634 CAW634N - -

4.0 CAW644 CAW644N - -

1.0 CAW615 CAW615N CAW715 CAW715N

5.52.0 CAW625 CAW625N CAW725 CAW725N

3.0 CAW635 CAW635N CAW735 CAW735N

4.0 CAW645 CAW645N CAW745 CAW745N

H

G/H

D

H

G/H

D

H

G/H

D

Hex Non-Hex

Hex Non-Hex

Hex Non-Hex

Hex Non-Hex

H

G/H

D

H

G/H

D

Hex Non-Hex

H

G/H

D

Hex Non-Hex

H

G/H

D

Hex

R-TypeScrew

Ti

EbonyGold

ASR200*

ASR200W

D ∅6.0

H G/HType

Hex Non-Hex

1.0 - -

7.02.0 TCAW627 TCAW627N

3.0 - -

4.0 TCAW647 TCAW647N

Screw

RASW200*

RASW200W

D ∅6.0

H G/HType

Hex Non-Hex

1.0 - -

7.02.0 RCAW627 -

3.0 - -

4.0 RCAW647 -

Screw

ScrewTi

EbonyGold

Ti

EbonyGold

Ti

EbonyGold

1.2

1.2

1.2

1.2

1.2

1.2

1.2ASR200*

ASR200W

※ EbonyGold Screw : Can be purchased separately

Page 18: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

35

US

Sys

tem

34

US

Sys

tem

US ZioCera Abutment

Angle G/H D ∅4.0

2.0 AAM4152C

4.0 AAM4154C

2.0 AAM4252C

4.0 AAM4254C

ASM200*

ASM200W

Mini

ScrewTi

EbonyGold

Ti

EbonyGold

Ti

EbonyGold

25°

15°

Angle G/H D ∅5.0

2.0 AAR5152C

4.0 AAR5154C

2.0 AAR5252C

4.0 AAR5254C

ASR200*

ASR200WScrew

25°

15°

Angle G/H D ∅6.0

2.0 AAW6152C

4.0 AAW6154C

2.0 AAW6252C

4.0 AAW6254C

ASW200*

ASW200WScrew

25°

15°

Angle G/H D ∅6.0

2.0 TAAW6152C

4.0 TAAW6154C

2.0 TAAW6252C

4.0 TAAW6254C

ASR200*

ASR200WScrew

Ti

EbonyGold

Ti

EbonyGold

25°

15°

Angle G/H D ∅6.0

2.0 RAAW6152C

4.0 RAAW6154C

2.0 RAAW6252C

4.0 RAAW6254C

RASW200*

RASW200WScrew

25°

15°

●Use for the path adjustment of prosthesis

● Gold color for aesthetic effect

● Double hex connection overcoming the limitation of the abutments’ direction

● Since screw loosening occurs somewhat frequently, EbonyGold screw is recommended

●Use a 1.2 hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : Ti screw : 30Ncm

EbonyGold screw : 20Ncm(mini), 30Ncm(regular & wide)

Order code - Abutment + Ti screw : Product code + TH (ex : AAR5152CTH)

Angled Abutment - Cement Retained Restoration

15° 25°

Regular

15° 25°

Wide

15°

15°

25°

Wide PS

25°

R-Type

15° 25°

G / H

G / H

G / H

G / H

G / H

D

D

D

D

D

OSSTEM IMPLANT SYSTEM

1.2

1.2

1.2

1.2

1.2

H G/HD ∅5.0

3.0 ZAM537

5.0 ZAM557

ASM200*

ASM200W

Mini

ScrewTi

EbonyGold

7.0

H G/H D ∅5.0 ∅6.0

3.0 ZAR537 ZAR637

5.0 ZAR557 ZAR657

ASR200*

ASR200WScrew

Ti

EbonyGold

7.0

●Use for esthetic implant restorations

● Ivory color for esthetic shade

● Applicable as a screw retained by direct build up.

●Use a 1.2 hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : Ti screw : 30Ncm

EbonyGold screw : 20Ncm(mini), 30Ncm(regular and wide)

Order code - Abutment + Ti Screw : Product Code + TH (ex : ZAR537TH)

ZioCera Abutment - Cement or Screw Retained Restoration

∅5.0

∅6.0

∅5.0

Regular

G / H

H

G / H

H

D

D

G / H

H

D

1.2

1.2

1.2

Hex

3.0

Hex

5.0

Hex

3.0

Hex

5.0

Hex

3.0

Hex

5.0

※ EbonyGold Screw : Can be purchased separately ※ EbonyGold Screw : Can be purchased separately

Page 19: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

37

US

Sys

tem

36

US

Sys

tem

UCLA Abutment Components

Type D ∅4.0

Hex GCM200

Non-Hex GCM100

Ti ASM200*

EbonyGold ASM200W

●Use for cases with path and aesthetic and spatial constraints

● After customization, be sure to use only dental gold alloy for casting to make the prosthesis

●Melting point range of abutment (Au, Pt, Pd alloy) : 1400-1450° (use of non-precious metal alloy for casting prohibited)

●Use a 1.2 hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : Ti screw : 30Ncm

EbonyGold screw : 20Ncm(mini), 30Ncm(regular & wide)

Order code - Abutment + Ti Screw : Product Code + TH (ex : GCR200TH)

Screw

Type D ∅4.5

Hex GCR200

Non-Hex GCR100

Ti ASR200*

EbonyGold ASR200WScrew

Mini

Hex Non-Hex

Regular

UCLA Gold Abutment - Screw or Cement Retained Restoration

Hex Non-Hex

12

D

12

D

1.2

1.2

US ZioCera Angled Abutment

●Used for the esthetic prosthesis (Zirconia)

● Ivory color similar to a natural tooth

● The use of direct build-up method enables the screw restoration

● The diameter which is useful and margin forms which are possible to modify

●Used for the path adjustment of anterior in case of 17。axial angle

●Use the 1.2 hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : 30Ncm (regular)

Order code - Abutment + Ti screw : Product Code + TH (ex : ZAAR5173TH)

ZioCera Angled abutment - Cement or Screw Retained Restoration

H G/H D ∅5.5 ∅6.5

3.0 ZAAR5173 -

4.0 - ZAAR6174

ASR200*

ASR200WScrew

Ti

EbonyGold

9.0

∅5.5 ∅6.5

Regular

1.2

Hex

G/H 3.0

Hex

G/H 4.0

G / H

H

17�

D

※ EbonyGold Screw : Can be purchased separately

※ EbonyGold Screw : Can be purchased separately

Page 20: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

39

US

Sys

tem

38

US

Sys

tem

1.2

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

Type D ∅4.0

Hex PSM200

Non-Hex PSM100

ASM200

●Use for cases with path and aesthetic and spatial constraints

● After customization, dental alloy (gold, non-precious metal) is used for casting

● Lower precision in the joints compared to UCLA Gold Abutments

●Use a 1.2 hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : 30Ncm

Order code - Abutment + Ti Screw : Product Code + TH (ex : PSR200TH)

Ti Screw

Type D ∅4.5

Hex PSR200

Non-Hex PSR100

ASR200Ti Screw

Mini

UCLA Plastic Abutment - Screw or Cement Retained Rstoration

Non-Hex Hex

Regular

Non-Hex Hex

D

12

D

12

1.2

Type D ∅5.5

Hex TGCW200

Non-Hex TGCW100

Ti ASR200*

EbonyGold ASR200WScrew

Type D ∅5.5

Hex RGCW200

Non-Hex RGCW100

Ti RASW200*

EbonyGold RASW200WScrew

Non-Hex Hex

Non-Hex Hex

Wide PS

R-Type

D

12

D

12

Type D ∅5.5

Hex GCW200

Non-Hex GCW100

Ti ASW200*

EbonyGold ASW200WScrew

Wide

Hex Non-Hex

12

D

1.2

1.2

1.2

Page 21: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

41

US

Sys

tem

40

US

Sys

tem

●Use to make temporary prothesis (material : Ti Gr-3)

● Easy to customize, designed to minimize indication constraints

●Use a 1.2 hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : 15Ncm

Order code - Abutment + Ti Screw : Product Code + TH (ex : TAR200TH)

Hex Non-Hex

Regular

UCLA Temporary Abutment - Temporary Restoration

Type D ∅4.0

Hex TAM200

Non-Hex TAM100

ASM200Ti Screw

Type D ∅4.5

Hex TAR200

Non-Hex TAR100

ASR200Ti Screw

Mini1.2

Hex Non-Hex

1.2

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

D

12

D

12

1.2Type D ∅5.5

Hex PSW200

Non-Hex PSW100

ASW200Ti Screw

Type D ∅5.5

Hex TPSW200

Non-Hex TPSW100

ASR200Ti Screw

Type D ∅5.5

Hex RPSW200

Non-Hex RPSW100

RASW200Ti Screw

Wide

Wide PS

R-Type

Non-Hex Hex

Non-Hex Hex

Non-Hex Hex

D

12

12

D

D

12

1.2

1.2

Page 22: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

43

US

Sys

tem

42

US

Sys

tem

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

Type D ∅4.0

13.5Hex ICPM402L

LNon-Hex ICPM401L

10.5Hex ICPM402S

Non-Hex ICPM401S

● Transfer type for taking an impression using a ready-made tray

● Triangular arc ( ) design improves markability following impression

● Long and short types enhance convenience

● The hex type is designed as a two-piece, and the non-hex type, as a one-piece

● Packing unit : Impression Coping body + Guide Pin (Hex)

Impression Coping (Non-Hex)

Mini

Fixture Transfer Impression Coping

Hex Non-Hex

Regular

Wide

D

L

Hex Non-Hex

D

L

Hex Non-Hex

D

L

Type D ∅5.0

13.5Hex ICPR502L

LNon-Hex ICPR501L

10.5Hex ICPR502S

Non-Hex ICPR501S

Type D ∅6.0

13.5Hex ICPW602L

LNon-Hex ICPW601L

10.5Hex ICPW602S

Non-Hex ICPW601S

Wide

Wide PS

Type D ∅5.5

Hex TAW200

Non-Hex TAW100

ASW200Ti Screw

Type D ∅5.5

Hex TTAW200

Non-Hex TTAW100

ASR200Ti Screw

Hex Non-Hex

1.2

Hex Non-Hex

1.2

R-Type Type D ∅5.5

Hex RTAW200

Non-Hex RTAW100

RASW200Ti Screw

1.2

D

12

Hex Non-Hex

D

D

12

12

Page 23: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

45

US

Sys

tem

44

US

Sys

tem

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

Type D ∅4.0

Hex ICFM400

Non-Hex ICFM400N

10 -

15 CSM150

17 -

● Pick-up type for taking an impression using a customized tray

● Impression coping designed with Hole-in-one ; no need for resin fixation

● Asymmetrical structure minimizing contact interference ( )

● Long and short types enhance convenience

● Packing unit : Impression Coping body + Guide Pin

Guide Pin (L)

Type D ∅6.0

Hex ICFW600

Non-Hex ICFW600N

10 CSW100

15 CSW150*

17 -

Guide Pin (L)

Guide Pin (L)

Hex

Non-Hex

Mini

Regular

Wide

Fixture Pick-Up Impression Coping - Long

Hex Non-Hex

L

1.2

Hex Non-Hex

Hex Non-Hex

1.2

L

1.2

L

∅5.0

ICFR500

ICFR500N

CSR100

CSR150*

CSR170

∅6.0

ICFR600

ICFR600N

10

15

17

Type D

D

D

D

12

12

12

Wide PS

R-Type

Hex Non-Hex

D

L

Hex Non-Hex

D

L

Type D ∅6.0

L13.5 Hex TICPW602

10.5 Non-Hex TICPW601

Type D ∅6.0

L13.5 Hex RICPW602

10.5 Non-Hex RICPW601

Page 24: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

47

US

Sys

tem

46

US

Sys

tem

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

Type D ∅5.0

Hex ICSR500

Non-Hex ICSR500N

10 CSR100*

15 CSR150

17 CSR170

● Pick-up type for taking an impression using a customized tray

● Impression coping designed with Hole-in-one ; no need for resin fixation

● Asymmetrical structure minimizing contact interference ( )

● Long and short types enhance convenience

● Packing unit : Impression Coping body + Guide Pin

Guide Pin (L)

Type D ∅6.0

Hex ICSW600

Non-Hex ICSW600N

10 CSW100*

15 CSW150

17 -

Guide Pin (L)

Regular

Fixture Pick-Up Impression Coping - Short

Non-Hex Hex

Wide

1.2

L

Hex Non-Hex

1.2

L

D

7

D

7

Type D ∅6.0

Hex TICFW600

Non-Hex TICFW600N

10 -

15 TCSW150

17 -

Guide Pin (L)

Type D ∅6.0

Hex RICFW600

Non-Hex RICFW600N

10 -

15 RCSW150

17 -

Guide Pin (L)

Wide PS

R-Type

Hex Non-Hex

1.2

L

1.2

L

Hex Non-Hex

D

12

D

12

Page 25: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

49

US

Sys

tem

48

US

Sys

tem

Mini

Regular

Wide

Wide PS

H G/H D ∅5.0 ∅6.0

1.0

2.0

3.0

4.0

1.0

2.0

3.0

4.0

1.0

2.0

3.0

4.0

ERAR514C -

ERAR524C -

ERAR534C -

ERAR544C -

ERAR515C ERAR615C

ERAR525C ERAR625C

ERAR535C ERAR635C

ERAR545C ERAR645C

ERAR517C -

ERAR527C -

ERAR537C -

ERAR547C -

4.0

5.5

7.0

H G/H D ∅6.0 ∅7.0

1.0

2.0

3.0

4.0

1.0

2.0

3.0

4.0

ERAW614C -

ERAW624C -

ERAW634C -

ERAW644C -

ERAW615C ERAW715C

ERAW625C ERAW725C

ERAW635C ERAW735C

ERAW645C ERAW745C

4.0

5.5

H G/HD ∅4.0

1.0 -

2.0 ERAM427C

3.0 -

4.0 ERAM447C

ASM200*

ASM200W

7.0

4.0 5.5

7.0

7.0

7.0

4.0

●Use for creating combination-type prosthesis with excellent retrievability

●Unique connection structure carrying the advantage

of both hex and non-hex types (maximum path compensation of 60 )

● Gingival gold color for aesthetic effect

● Tapered body design facilitating prosthetic fit

● Cross-section design for the prevention of prosthesis rotation

●Use a 1.2 hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque :

Ti screw : 30Ncm

EbonyGold screw : 20Ncm(mini), 30Ncm(regular and wide)

Order code - Abutment + Ti Screw : Product Code + TH

(ex : ERAR525CTH)

ER Abutment - Screw & Cement Retained Restoration

5.5

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

D

G / H

H

G / H

H

G / H

H

D

D

D

G/H

H

ScrewTi

EbonyGold

Ti

EbonyGold

Ti

EbonyGold

H G/HD ∅6.0

1.0 -

2.0 TERAW627C

3.0 -

4.0 TERAW647C

ASR200*

ASR200W

7.0

Screw

Screw

Screw

ASR200*

ASR200W

ASW200*

ASW200W

Cement Abutment ER Abutment

Ti

EbonyGold

1.2

1.2

1.2

1.2

Mini FAM300

Regular FAR300

Wide FAW300

Wide PS TFAW300

R-Type RFAW300

● Oral fixtures are built on the working model

● Packing unit : Lab analog

Mini UPCM100

Regular UPCR100

Wide UPCW100

Wide PS TUPCW100

R-Type RUPCW100

● For polishing upon prosthetic casting, use to avoid damaging the cylinder joint

● Packing unit : Polishing protector

Fixture Lab Analog

UCLA Polishing Protector

Mini Regular Wide Wide PS R-Type

Mini Regular Wide Wide PS R-Type

2.4 2.7 3.4 2.7 3.3

※ EbonyGold Screw : Can be purchased separately

Page 26: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

51

US

Sys

tem

50

US

Sys

tem

Esthetic Abutment Components

●Use for making aesthetic screw-retained prosthesis

● Designed to make the prosthesis onto a cylinder following abutment

connection in the oral cavity

●Maximum path compensation of 30

●Use a 2.0 internal hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : 30Ncm

Order code - Abutment + Ti screw : Product code + TH (ex : EAR200TH)

Esthetic Abutment - Screw Retained Restoration

●Use for the protection of aesthetic abutments in the oral cavity and to

minimize the patient's discomfort

●Use a 1.2 hex driver

● Packing unit : Healing cap

● Tightening torque : 20 Ncm

Esthetic Healing Cap

Regular

Regular

GH D ∅4.8

1.0 EAR100

2.0 EAR200

3.0 EAR300

4.0 EAR4002.0

1.2

H D ∅4.8

6.0 EHC100

D

D

H

G / H

1.8H G/H D ∅4.8

1.0 SFAR514SC

4.0 2.5 SFAR524SC

4.0 SFAR544SC

1.0 SFAR515SC

5.5 2.5 SFAR525SC

4.0 SFAR545SC

1.0 SFAR517SC

7.0 2.5 SFAR527SC

4.0 SFAR547SC

5.5 7.0

Regular

H G/H D ∅6.0

1.0 SFAW614SC

4.0 2.5 SFAW624SC

4.0 SFAW644SC

1.0 SFAW615SC

5.5 2.5 SFAW625SC

4.0 SFAW645SC

1.0 -

7.0 2.5 -

4.0 -

Wide

●Use for making single prosthesis to prevent screw loosening

● Oval-shaped abutment body prevents prosthesis rotation

● Screw loosening is prevented, since screws are fixed to the

prosthesis

● Gingival gold color for aesthetic effect

●Use a 1.2 hex driver

● Packing unit : Abutment + Ti screw + carrier cap + protect cap

● Tightening torque : 30 Ncm

Safe Abutment - Cement Retained Restoration

4.0

4.0 5.5

G / H

H

D

G / H

H

D

Circle

Ellipse

section

Page 27: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

53

US

Sys

tem

52

US

Sys

tem

● Preliminary impression copings exclusively for aesthetic abutments

● Transfer type for taking an impression using a ready-made tray

● Packing unit : Impression coping

● Final impression copings exclusively for aesthetic abutments

● Pick-up type for taking an impression using a customized tray

● Impression coping designed with Hole-in-one ; no need for resin fixation

● Asymmetrical structure minimizing contact interference ( )

● Packing unit : Impression coping body + Guide Pin

● For polishing upon prosthetic casting, use to avoid damaging the cylinder joint

● Packing unit : Polishing protector

Regular

Type D ∅4.8

Hex ESR200

Non-Hex ESR100

10 GP100

15 GP150*

17 GP170

20 GP200

Guide Pin (L)

Regular

Esthetic Transfer Impression Coping

Esthetic Pick-up Impression Coping

Regular

Esthetic Lab Analog

Regular

Esthetic Polishing Protector

Hex Non-Hex

Regular ERR300

Regular EPCR100

●Make aesthetic oral abutments on the working modek

● Packing unit : Lab analog

L

8.0

H

H D ∅4.8

8.0 ETR100

1.2

D

D

● After customization, be sure to use only dental gold alloy for casting to

make the prosthesis

●Melting point range of cylinder (Au, Pt, Pd Alloy): 1400 - 1450。C

(use of non-precious metal alloy for casting prohibited)

●Use a 1.2 hex driver

● Packing unit : Cylinder + EbonyGold screw

Cylinder + Ti screw

● Tightening torque : 20 Ncm

Order code - Cylinder + EbonyGold screw : Product code + WH (ex : EGC200WH)

- Cylinder + TI screw : Product code + TH (ex : EGC200TH)

●Use for creating temporary prosthesis for aesthetic abutments

(material : Ti Gr-3)

● Easy to customize : designed to minimize indication constraints

●Use a 1.2 hex driver

● Packing unit : Cylinder + Ti screw

● Tightening torque : 15Ncm

Order code - Cylinder + Ti screw : Product code + TH (ex : ETT200TH)

● After customization, dental alloy (gold, non-precious metal) is used for

casting

● The precision of the connection part is lower compared to gold cylinders

●Use a 1.2 hex driver

● Packing unit : Cylinder + Ti screw

● Tightening torque : 20Ncm

Order code - Cylinder + Ti screw : Product code + TH (ex : EPS200TH)

Type D ∅4.8

Hex EGC200

Non- Hex EGC100

Ti Screw TS200*

TS200WEbonyGold Screw

Type D ∅4.8

Hex EPS200

Non-Hex EPS100

TS200Ti Screw

Type D ∅4.8

Hex ETT200

Non-Hex ETT100

TS200Ti Screw

Regular

Esthetic Gold Cylinder

Non-Hex Hex

Hex Non-Hex

Regular

Esthetic Plastic Cylinder

Regular

Esthetic Temporary Cylinder

1.2

1.2

D

12

Hex Non-Hex

D

12

1.2

D

12

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

Page 28: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

55

US

Sys

tem

54

US

Sys

tem

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

Regular

Type D ∅4.8

Hex MGR200

Non-Hex MGR100

Ti Screw MTS200*

MTS200W

● After customization, be sure to use only dental gold alloy for casting to

make the prosthesis

●Melting point range of cylinder (Au, Pt, Pd Alloy) : 1400 - 1450。C

(use of non-precious metal alloy for casting prohibited)

●Use a 1.2 hex driver

● Packing unit : Cylinder + EbonyGold screw

Cylinder + Ti screw

● Tightening torque : 20 Ncm

Order code - Cylinder + EbonyGold screw : Product code + WH(ex : MGR200WH)

- Cylinder + Ti screw : Product code + TH(ex : MGR200TH)

EbonyGold Screw

Wide Wide PS

Type D ∅5.5

Hex MGW200

Non-Hex MGW100

Ti Screw WTS200*

WTS200WEbonyGold Screw

Regular

Regular

Esthetic-low Gold Cylinder

Non-Hex Hex

Non-Hex Hex

Wide | Wide PS

Regular

Type D ∅4.8

Hex MEPR200

Non-Hex MEPR100

MTS200Ti Screw

● After customization, dental alloy (gold, non-precious metal) is used for

casting

● The precision of the connection part is lower compared to gold cylinders

●Use a 1.2 hex driver

● Packing unit : Cylinder + Ti screw

● Tightening torque : 20 Ncm

Order code - Cylinder + Ti screw : Product code + TH (ex : MEPR200TH)

Wide Wide PS

Type D ∅5.5

Hex MEPW200

Non-Hex MEPW100

WTS200Ti Screw

Esthetic-low Plastic Cylinder

Wide I Wide PS

1.2

1.2

1.2

1.2

D

Non-Hex Hex

D

D

Non-Hex Hex

D

12

12

Esthetic-low Abutment Components

Regular Wide | Wide PS

Esthetic-low Healing Cap

●Use in case of small gap with antagonist teeth due to the smaller height

compared to aesthetic abutments

●Maximum path compensation of 48。

●Use 2.0 (regular) and 2.7 (wide) internal hex drivers

● Packing unit : Abutment + Ti screw

● Tightening torque : 30 Ncm

Order code - Abutment + Ti screw : Product code + TH (ex : MER200TH)

●Use for the protection of aesthetic low abutments in the oral cavity and to

minimize the patient's discomfort

●Use a 1.2 hex driver

● Packing unit : Healing cap

● Tightening torque : 20 Ncm

Esthetic-low Abutment- Screw Retained Restoration

Regular Wide Wide PS

G/H D ∅4.8 ∅5.5

1.0 MER100 MEW100 TMEW100

2.0 MER200 MEW200 TMEW200

3.0 MER300 MEW300 TMEW300

4.0 MER400 MEW400 TMEW4002.0

1.2 1.2

Regular Wide Wide PS

G/H

D

2.7 2.7

D

H

H D

4.6

Regular

∅4.8

MHCR100

Wide Wide PS

∅6.0

MHCW100

※ EbonyGold Screw : Can be purchased separately

Page 29: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

57

US

Sys

tem

56

US

Sys

tem

●Make aesthetic oral abutments on the working model

● Packing unit : Lab analog

Regular

Type D ∅4.8

Hex MSR200

Non-Hex MSR100

10 GP100

15 GP150*

17 GP170

20 GP200

Guide Pin (L)

● Final impression copings exclusively for aesthetic low abutments

● Pick-up type for taking an impression using a customized tray

● Impression coping designed with Hole-in-one ; no need for resin fixation

● Asymmetrical structure minimizing contact interference ( )

● Packing unit : Impression coping body + Guide Pin

Wide Wide PS

Type D ∅5.5

Hex MSW200

Non-Hex MSW100

10 GPW100

15 GPW150*

17 -

20 -

Guide Pin (L)

Regular

Esthetic-low Pick-up Impression Coping

Regular

Esthetic-low Polishing Protector

Wide

Regular Wide | Wide PS

Esthetic-low Lab Analog

● For polishing upon prosthetic casting, use to avoid damaging the cylinder joint

● Packing unit : Polishing protector

Wide | Wide PS

Regular MPCR100

Wide | Wide PS MPCW100

Regular MERR300

Wide | Wide PS MERW300

Hex Non-Hex

L

L

Hex Non-Hex

8.0

D

8.0

D

1.2

1.2

Esthetic-low Temporary Cylinder

Esthetic-low Transfer Impression Coping

Regular

●Use for creating temporary prosthesis for aesthetic low abutments

(material : Ti Gr-3)

● Easy to customize : designed to minimize indication constraints

●Use a 1.2 hex driver

● Packing unit : Cylinder + Ti screw

● Tightening torque : 15Ncm

Order code - Cylinder + Ti Screw : Product Code + TH (ex : MTR200TH)

Regular Wide | Wide PS

Wide | Wide PS

Hex Non-Hex

Wide Wide PS

Type D ∅6.0

Hex MTW200

Non-Hex MTW100

WTS200Ti Screw

12

12

● Preliminary impression copings exclusively for aesthetic low abutments

● Transfer type for taking an impression using a ready-made tray

● Packing unit : Impression coping

H D

8.0

Regular

∅4.8

MTTR100

Wide Wide PS

∅5.5

MTTW100

H

D

1.2

1.2

Regular

Type D ∅5.3

Hex MTR200

Non-Hex MTR100

Ti Screw MTS200

Hex Non-Hex

D

D

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

Page 30: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

59

US

Sys

tem

58

US

Sys

tem

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

●Use for creating temporary prosthesis for standard abutments

(material : Ti Gr-3)

● Easy to customize : designed to minimize indication constraints

●Use a 1.2 hex driver

● Packing unit : Cylinder + Ti screw

● Tightening torque : 15Ncm

Order code - Cylinder + Ti Screw : Product Code + TH (ex : STT100TH)

● Preliminary impression copings exclusively for standard abutments

● Transfer type for taking an impression using a ready-made tray

● Packing unit : Impression coping

Regular

Standard Temporary Cylinder

Regular

Standard Transfer Impression Coping

● After customization, dental alloy (gold, non-precious metal) is used for

casting

● The precision of the connection part is lower compared to gold cylinders

●Use a 1.2 hex driver

● Packing unit : Cylinder + Ti screw

● Tightening torque : 20 Ncm

Order code - Cylinder + Ti screw : Product code + TH (ex : SPS100TH)

Regular

Standard Plastic Cylinder H D ∅4.5

12 SPS100

TS200Ti Screw

H D ∅5.3

12 STT100

TS200Ti Screw

D

H

D

H

D

H

H D ∅4.5

8.0 STR100

1.2

1.2

Standard Abutment Components

●Use for making a hybrid denture or a bridge requiring hygiene control

●More advantageousfor oral hygiene due to the design of the prosthesis for

the upper gingiva

●Use a 2.0 internal hex driver

● Packing unit : Abutment + Ti screw

● Tightening torque : 30 Ncm

Order code - Abutment + Ti screw : Product code + TH (ex : SAR300TH)

●Use for the protection of standard abutments in the oral cavity and to

minimize the patient's discomfort

●Use a 1.2 hex driver

● Packing unit : Healing cap

● Tightening torque : 20 Ncm

● After customization, be sure to use only dental gold alloy for casting to make

the prosthesis

●Melting point range of cylinder (Au, Pt, Pd Alloy) : 1400 - 1450。C

(use of non-precious metal alloy for casting prohibited)

●Use a 1.2 hex driver

● Packing unit : Cylinder + EbonyGold screw

Cylinder + Ti screw

● Tightening torque : 20 Ncm

Order code - Cylinder + EbonyGold screw : Product code + WH(ex : SGC300WH)

- Cylinder + Ti screw : Product code + TH(ex : SGC300TH)

Standard Abutment - Screw Retained Restoration

Regular

Standard Healing Cap

Regular

Standard Gold Cylinder

H D ∅4.5

3.0 SAR300

4.0 SAR400

5.5 SAR550

7.0 SAR700

8.5 SAR850

H D ∅4.5

1.0 SGC300

2.0 SGC400

Ti Screw SGC400

TS200WEbonyGold Screw

H

H

Hex 1.2

Hex 2.0

D

H D ∅4.5

3.5 SHC100

D

H

D

1.2

Regular

※ EbonyGold Screw : Can be purchased separately

Page 31: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

61

US

Sys

tem

60

US

Sys

tem

O-ring System

●Use for making stud-type overdenture

● O-ring components

For lab use : Black color

For denture : Yellow color (4N), orange color (6N)

● Compensate the retention force through O-ring replacement

●Maximum path compensation of 20。

●Use an O-ring abutment driver

● Packing unit : Abutment + Retainer Cap + O-rings

● Tightening torque : 30 Ncm

O-ring Abutment Set (O-ring Set)Overdenture Restoration

G/H D ∅5.0

2.0 OAA200S

3.0 OAA300S

4.0 OAA400S

5.0 OAA500S

6.0 OAA600S

●Use for making stud-type overdenture

● Superior stability of retention force vs. O-ring

● Dalbo plus attachment components

Housing (Ti) + Internal lamella (gold alloy)

Duplicate aid (plastic)

● Compensate the retention force through internal lamella rotation

(clockwise) using a special-purpose driver

●Maximum path compensation of 20

●Use an O-ring abutment driver

● Packing unit : Abutment + Dalbo plus attachments

● Tightening torque : 30 Ncm

O-ring Abutment Set (Dalbo Set)Overdenture Restoration

G/H D ∅5.0

2.0 OAA200D

3.0 OAA300D

4.0 OAA400D

5.0 OAA500D

6.0 OAA600D

D

G / H

D

G / H

● Final impression copings exclusively for standard abutments

● Pick-up type for taking an impression using a customized tray

● Impression coping designed with Hole-in-one ; no need for resin fixation

● Asymmetrical structure minimizing contact interference ( )

● Packing unit : Impression coping body + Guide Pin

Regular

Standard Pick-up Impression Coping H D ∅4.5

8.0 SSR100

10 GP100

15 GP150*

17 GP170

20 GP200

Guide Pin (L)

●Make aesthetic oral abutments on the working model

● Packing unit : Lab analog

● For polishing upon prosthetic casting, use to avoid damaging the cylinder joint

● Packing unit : Polishing protector

Regular SRR300

Regular SPCR100

Regular

Standard Lab Analog

Regular

Standard Polishing Protector

LH

1.2

D

● Packing unit : Only abutment

O-ring AbutmentOverdenture Restoration

G/H D ∅5.0

2.0 OAA200

3.0 OAA300

4.0 OAA400

5.0 OAA500

6.0 OAA600

D

G / H

Page 32: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

63

US

Sys

tem

62

US

Sys

tem

● O-ring for making the overdenture used in laboratories

● Packing unit : O-rings 5 piece

O-ring Set (for Laboratory) Code OAO100S

● Oral O-ring with low retention force (approximately 4N)

● Packing unit : O-rings 5 piece

O-ring Set (Low Retention) Code OAO400S

● Oral O-ring with high retention force (approximately 6N)

● Packing unit : O-rings 5 piece

O-ring Set (High Retention) Code OAO600S

●Make oral O-ring abutments on the working model

● Packing unit : Lab analog

O-ring Lab Analog Code OAL

OSSTEM IMPLANT SYSTEMM R W Fixture Platform

● Selective application through 2 types of O-ring retention force

● Excellent retention force and good sense of denture placement

● Packing unit : Retainer cap + O-rings

Retainer Cap Set Code OARCS

●More advantageous for smaller occlusal gap compared to a retainer cap

● Packing unit : Retainer + O-rings

Retainer Set Code OARS

Page 33: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration

65

US

Sys

tem

64

US

Sys

tem

● Packing Unit : Locator Male Processing Kit (2 Set)

● Consist of

-Block out Spacer/Denture Cap connected Black Processing Male

-Replacement Male Blue/Pink/Clear

●Male Change by Locator Core Tool

Code LMPS

LOCATOR� Components

HU LOCATOR� AbutmentOverdenture Restoration

LOCATOR� Male Processing Kit

D

1.5mm

G/H● Packing unit : Locator abutment

● Stable dual retention & optimal holding capabilities against various

retention forces (6N, 12N, 22N)

● Excellent durability

● Possible denture restorations even at small vertical dimension

● Accommodate up to 40�divergence between two implants

● Retention males can be easily placed & removed with core tool

● Tightening torque : 30Ncm

● Can be used in US system & HU system

G/H D ∅3.5 ∅4.0

1 HULCA3510M HULCA4010R

2 HULCA3520M HULCA4020R

3 HULCA3530M HULCA4030R

4 HULCA3540M HULCA4040R

5 HULCA3550M HULCA4050R

● Packing Unit : Blue Replacement Male (4ea)

● retention Force : about 6N

● 0�~20�divergence (between two implants)

Code LRM06S

● Packing Unit : Pink Replacement Male (4ea)

● retention Force : about 12N

● 0�~20�divergence (between two implants)

Code LRM12S

● Packing Unit : clear Replacement Male (4ea)

● retention Force : about 22N

● 0�~20�divergence (between two implants)

Code LRM22S

LOCATOR� Replacement Male

● Packing Unit : Red Extended Replacement Male (4ea)

● retention Force : about 6N

● 20�~40�divergence (between two implants)

Code LEM06S

● Packing Unit : Green Extended Replacement Male (4ea)

● retention Force : about 12N

● 20�~40�divergence (between two implants)

Code LEM12S

LOCATOR� Extended Replacement Male

● Packing Unit : black processing Male (4ea)

● for lab. process

Code LBPSLOCATOR� Black Processing Male

● Packing Unit : Locator Block out spacers (20ea)

● For Space Sealing between Locator Abutment & Denture Cap

Code LBSSLOCATOR� Block out spacers

● Packing Unit : Locator Impression Coping (4ea)

● For Abutment level impression

Code LICSLOCATOR� Impression Coping

● Packing Unit : Locator lab Analog (4ea)

LAL40S

LAL50SCode

LOCATOR� lab Analog

● Packing Unit : Locator Torque Driver

● For tightening of Locator Abutment

● Select the Short/Long length

LOCATOR� Torque Driver

● Packing Unit : Locator Core Tool

● foe handling of locator system

Code LCCTLOCATOR� Core Tool

Type Short Long

Code TWLDS TWLDL

Page 34: Components US System SYSTEMIMPLANTOSSTEM - …biofisa.com/downloads/biofisa-us.pdf · production of USII Approved by the FDA in the US ... US System- Biology 1 ... Bone Regeneration