components us system systemimplantosstem - …biofisa.com/downloads/biofisa-us.pdf · production of...
TRANSCRIPT
US SystemFixture and Restorative
Components
OSSTEMIMPLANTSYSTEM
US System
Contents | OSSTEM IMPLANT
32
24US II RBM
Fixture
26US III RBM
Fixture
28US Ultra
Wide�
Fixture
30Cover Screw
30Headless
Cover Screw
31Healing
Abutment
34Cement
Abutment
36Angled
Abutment
39UCLA Gold
Abutment
41UCLA Plastic
Abutment
37ZioCera
Abutment
43UCLA
Temporary
Abutment
45Fixture
Transfer
Impression
Coping
50Fixture
Lab Analog
50UCLA
Polishing
Protector
51ER
Abutment
52Safe
Abutment
53Esthetic
Abutment
53Esthetic
Healing Cap
54Esthetic
Gold Cylinder
54Esthetic
Plastic
Cylinder
55Esthetic
Transfer
Impression
Coping
55Esthetic
Pick-up
Impression
Coping
54Esthetic
Temporary
Cylinder
55Esthetic
Lab Analog
55Esthetic
Polishing
Protector
56Esthetic-low
Healing Cap
57Esthetic-low
Gold Cylinder
56Esthetic-low
Abutment
57Esthetic-low
Plastic
Cylinder
58Esthetic-low
Temporary
Cylinder
58Esthetic-low
Transfer
Impression
Coping
59Esthetic-low
Lab Analog
59Esthetic-Low
Pick-up
Impression
Coping
59Esthetic-low
Polishing
Protector
60Standard
Abutment
60Standard
Healing Cap
60Standard
Gold Cylinder
61Standard
Plastic
Cylinder
61Standard
Temporary
Cylinder
62Standard
Polishing
Protector
62Standard
Lab Analog
62Standard
Pick-up
Impression
Coping
61Standard
Transfer
Impression
Coping
63O-ring
Abutment
Set
(O-ring Set)
64O-ring
Retainer
Cap Set
64O-ring
Retainer Set
65O-ring Set
65O-ring
Lab Analog
63O-ring
Abutment Set
(Dalbo Set)
63O-ring
Abutment
49Fixture
Pick-up
Impression
Coping - Short
66LOCATOR
Abutment
66LOCATOR
Extened
Replacement
Male
67LOCATOR
Impression
Coping
67LOCATOR
Lab Analog
67LOCATOR
Core Tool
67LOCATOR
Torque Driver
66LOCATOR
Male Processing
Kit
66LOCATOR
Black
Processing
Male
66LOCATOR
Black
Processing
Male
67LOCATOR
Black out
Spacer
47Fixture
Pick-up
Impression
Coping- Long
30Simple Mount
4 5
US
Sys
tem
US
Sys
tem
OSSTEM IMPLANT R&D Center
Universities/Other
Research InstitutesEducational-industrial projects
GovernmentResearch cooperation with
governmental projects
Customer ClinicsFeed Backs/opinions
Associated Clinical Hospital
Joint clinical research works
OSSTEM IMPLANT
R&D Center
OSSTEM IMPLANT
●Market Share & Brand Recognition NO. 1 In Korean Market
●World Class Product Quality(FDA, CE, ISO9001)
●Enhanced Research & Development Through Impant R&D Center
● Independent Models Development and Production(SSII, GSII)
●A Wide Range of Products with Excellent Compatibility
●Most Advanced Facilities with the Largest Production Capacity in Asia
●Export to the worldwide
●Future Expansion Plan To Over 100 Countries For The Next Five Years
●Active Systematic Impant Clinical Training Through AIC Center
OSSTEM IMPLANT R&D Center
OSSTEM R&D Center consists of 25 professionals who
have doctral/master’s degree in each field.
OSSTEM keeps investing in research and development
area with high tech equipment.
OSSTEM also cooperates with government agencies,
universities, and hospitals in many projects and in-depth
studies.
OSSTEM HISTORY
May Developed and commenced the commercial production of GSII
Apr "OSSTEM MEETING 2005" held in Seoul
(2,700 attendees)
Mar Certified KGMP(Korean Good Manufacturing Practice) in Korea
Published the "2005 OSSTEM IMPLANT SYSTEM (Introduction)"
Jan Established the subsidiary office in Taiwan(Taipei)
Nov Developed and commenced the commercial production of SSIII
Jul Developed and commenced the commercial production of USIII
Apr "OSSTEM MEETING 2004" held in Seoul (1,200 attendees)
Nov Developed and applied its own automatic cleaning system
Jul Established the OSSTEM Information System R&D Center
Oct Developed and commenced the commercial
production of SSII
Aug Developed and commenced the commercial
production of USII Approved by the FDA in the US
Mar Concluded partnership agreement with KaVo(Kaltenbach & Voigt)
Jan Established the OSSTEM Implant R&D Center
Mar Established the AIC
(Apsun Dental Implant Research & Education Center)
Jan CE-0434 Mark certified
Oct Certified ISO-9001
Dec Commenced the commercial production
(brand name : OSSTEM)
Jan Established the Company in Korea
(OSSTEM Co., Ltd.)
Developed the implant and acquired an industrial license
Launched the development of dental implant system
2009
2007
2005
2008
2006
2005
2003
2001
1997
1992
2004
2002
1999
1995
Oct Approved by the Ministry of Health, Labour and Welfare in Japan
Aug ‘2009 OSSTEM MEETING Hong Kong’ held
Oct '2008 OSSTEM MEETING Singapore' held
Aug '2008 OSSTEM MEETING Hong Kong' held
Jul '2008 OSSTEM MEETING Taiwan' held in Taipei
Jun Development and sales of GSIII implant
Apr '2008 AIC World Meeting' held in Seoul
Mar Established ATC training center
'2008 OSSTEM MEETING Thailand' held in Bangkok
Jan Established OSSTEM Bone Science Institute
Nov ‘2007 OSSTEM MEETING Malaysia’ held in Kuala Lumpur
‘2007 OSSTEM MEETING USA’ held in Los Angeles
Oct ‘2007 OSSTEM MEETING India’ held in Mumbai
‘2007 OSSTEM MEETING Russia’ held in Moscow
Established the incorporate subsidiary in Australia(Sydney)
Sep ‘2007 OSSTEM MEETING Hong Kong’ held
‘2007 OSSTEM MEETING Singapore’ held
Jul ‘2007 OSSTEM MEETING Taiwan’ held in Taipei
Jun Approved by the TGA in Australia
May KFDA approved OSSTEM tissue bank foundation
Apr Published "2006 OSSTEM IMPLANT SYSTEM" in English Version
"OSSTEM MEETING 2007" held in Seoul (12,000 attended)
Feb Listed on KOSDAQ (KRX : Korea Exchange)
Dec Established the subsidiary offices in
Thailand(Bangkok), and Malaysia(Kuala Lumpur)
Nov Approved by the SFDA in China
Sep Established the U.S Corporate Headquarter and started
construction of manufacturing facility in the US
Aug Established the subsidiary offices in
China(Beijing), Hongkong, and Singapore
Jul Established the subsidiary office in Japan(Tokyo)
Apr Certified GOST-R in Russia
"OSSTEM MEETING 2006" held in Seoul
(6,500 attendees) Published the "2006 OSSTEM IMPLANT SYSTEM
(introduction and particulars of implant system)"
Jan Established the subsidiary offices in India(Mumbai)
and Russia(Moscow)
Dec Completed, relocated new production plant in Busan
Established the subsidiary office in Germany(Ashborn)
Approved by the DOH in Taiwan
7
US
Sys
tem
6
US
Sys
tem
CHARACTERISTIC of OSSTEM IMPLANT SYSTEM
Evaluation of Sinus Bone Resorption and Marginal Bone Loss after
Sinus Bone Grafting and Implant PlacementYoung-Kyun Kim et al.
No. Title Reference Author
■US System- Clinic
1
Evaluation of Periimplant Tissue Response according to the
Presence of Keratinized Mucosa
Oral Surg Oral Med Oral Pathol OralRadiol Endod
2009;107:e24-8
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
2009;107:e21-8
Young-Kyun Kim et al.2
Correlation Between Bone Quality Evaluated by Cone-Beam
Computerized Tomography and Implant Primary StabilityInt J Oral Maxillofac Implants 2009;24(1):59-64 Jong-Jin Kwon et al.3
Clinical and Radiographic Evaluation of Implants with
Dualmicrothread:1-year StudyJ Korean Acad Periodontol 2009;39(1):27-36 Ju-Youn Lee et al.4
Bone Density and Histomorphometry Assessment ofDental Implant
Using Computerized Tomography
J Korean Assoc Maxillofac Plast Reconstr Surg
2009;31(2):137-46Yeong-Cheol Cho et al.5
Implant Replacement Utilizing Zirconia Abutment in EstheticZone J Korean Implantology(KAOMI) 2009;13(2):16-24 Sok-Min Ko et al.6
A Retrospective Study on the Clinical Success Rate of
OsstemImplantKey Engineering Materials 2008;361-363:1331-4 Su-Kwan Kim et al.7
Multicenter Retrospective Study of Immediate Two Different RBM
Surfaced Implant Systems after Extraction
J Korean Assoc MaxillofacPlast Reconstr Surg
2008;30(3):258-65Hee-Kyun Oh et al.8
A Retrospective Multicenter Clinical Study of Installed US II / SS II
Implants after Maxillary Sinus Floor ElevationJ Kor Oral Maxillofac Surg 2008;34:341-9 Hee-Kyun Oh et al.9
Clinical Retrospective Study of Sinus Bone Graft and Implant
Placement
J Korean Assoc Maxillofac Plast ReconstrSurg
2008;30(3):294-302Young-Kyun Kim et al.10
A Retrospective Evaluation of Implant Installation with Maxillary
Sinus Augmentation by Lateral Window Technique
J Korean Assoc Maxillofac Plast Reconstr Surg
2008;30(5):457-64Hee-Kyun Oh et al.11
Short term Retrospective Clinical Study on GS II, SS III, US III J Korean Implantology(KAOMI) 2008;12(2):12-22 Young-Kyun Kim et al.12
Multicenter Retrospective Clinical Study of Osstem US II
ImplantSystem in Type IV BoneJ Korean Implantology(KAOMI) 2007;11(3):22-9 Su-Kwan Kim et al.13
Multicenter Retrospective Clinical Study of Osstem US II
ImplantSystem in Complete Edentulous PatientsJ Korean Implantology(KAOMI) 2007;11(3):12-21 Su-Kwan Kim et al.14
Retrospective Multicenter Cohort Study of the Clinical Performance
of 2-stage Implants in South Korean PopulationsInt J Oral & Maxillofac Implants 2006;21(5):785-8 Seok-Min Ko et al.15
Analysis of Clinical Application of Osstem (Korea) Implant System
for 6 YearsJ Korean Implantology(KAOMI) 2006;10(1):56-65 Young-Kyun Kim et al.16
Multicentric Prospective Clinical Study of KoreanImplant System:
Early Stability Measured by PeriotestJ Korean Dent Assoc 2004;42(12):873-81 Young-Kyun Kim et al.17
A Comparative Study of Two Noninvasive Techniques to Evaluate
Implant Stability: Periotest and Osstell MentorSu-Gwan Kim et al.
No. Title Reference Author
■US System- Biology
1
Effects of Different Depths of Gap on Healing of Surgically Created
Coronal Defects around Implants in Dogs: A Pilot StudyJ Periodontol 2008;79(2):355-61
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
2009;107:513-8
June-Sung Shim et al.2
Histologic and Histomorphometric Evaluation of Early and
Immediately Loaded Implants in the Dog MandibleJ Biomed Mater Res 2008;86A:1122-7 Su-Gwan Kim et al.3
The Effect of Surface Treatment of the Cervical Area of Implant on
Bone Regeneration in Mini-pigJ Kor Oral Maxillofac Surg 2008;34:285-92 Hong-Ju Park et al.4
Comparative Study of Removal Effect on Artificial Plaque from RBM
Treated Implant
J Korean Assoc Maxillofac Plast Reconstr Surg
2007;29(4):309-20Hee-Jyun Oh et al.5
Comparative Study of Osseointegration of 4 Different Surfaced
Implants in the Tibia of DogsJ Kor Oral Maxillofac Surg 2005;31:46-54 Hee-Jyun Oh et al.6
Effect of Implant Surface Characteristics on Osseointegration in the
Ilium of Dogs
J Korean Assoc Maxillofac Plast Reconstr Surg
2004;36(6):531-41Hee-Jyun Oh et al.7
Effect of Tightening Torque on Abutment-Fixture Joint Stability
using 3-Dimensional Finite Element AnalysisChang-Mo Jeong et al.
No. Title Reference Author
■US System- Biomechanics
3
Screw Joint Stability under Cyclic Loading of Zirconia Implant
AbutmentsJ Kor Acad Prosthodont 2009;47(2):164-73
J Kor Acad Prosthodont 2009;47(2):125-35
Jae-Jun Ryu et al.4
Heat Transfer to the Implant-Bone Interface during preparation of
Zirconia/Alumina Complex AbutmentYong-Geun Choi et al.1
Fatigue Fracture of Different Dental Implant System under Cyclic
LoadingJ Kor Acad Prosthodont 2009;47(4):424-34
Int J Oral Maxillofac Implants 2009;24(4):679-83
In-ho Cho et al.2
Influence of Tightening Torque on Implant-Abutment Screw Joint
StabilityJ Kor Acad Prosthodont 2008;46(4):396-408 Chang-Mo Jeong et al.5
Influence of Tungsten Carbide/Carbon Coating of Implant-
Abutment Screw on Screw LooseningJ Kor Acad Prosthodont 2008;46(2):137-47 Chang-Mo Jeong et al.6
The Assessment of Abutment Screw Stability Between the External
and Internal Hexagonal Joint under Cyclic LoadingJ Kor Acad Prosthodont 2008;46(6):561-8 Jung-Suk Han et al.7
Influence of Implant Fixture Design on Implant Primary Stability J Kor Acad Prosthodont 2006;45(1):98-106 Seok-Gyu Kim et al.8
An Influence of Abutment Materials on a Screw-Loosening after
Cyclic LoadingJ Kor Acad Prosthodont 2007;45(2):240-249 Jung-Suk Han et al.9
Influence of Tungsten Carbide/Carbon on the Preload of Implant
Abutment ScrewsJ Kor Acad Prosthodont 2006;44(2):229-42 Chang-Mo Jeong et al.10
The Effect of Internal Implant-Abutment Connection and Diameter
on Screw LooseningJ Kor Acad Prosthodont 2005;43(3):379-92 Kyung-Soo Jang et al.11
Wave Analysis of Implant Screw Loosening using an Air Cylindrical
Cyclic Loading DeviceJ Prosthet Dent 2002;88:402-8 Jung-Suk Han et al.12
The Comparative Study of Mechnical Stability Between Self Tapping
Fixture and Double Threaded Fixture by 3-dimensional Finite
Element Analysis
J Kor Acad of General Dentistry 1999;1(1):73-81 Byung-nam Hwang et al.14
Preliminary Study on the Design of Screw Head for Rapid Fastening
& LooseningJ Kor Acad Family Medcine 2000;2(2):26-31 Jae-Bong Lee13
8 9
CHARACTERISTIC of OSSTEM IMPLANT SYSTEM
Reliable implant that has acquired various international quality certifications (FDA, CE, ISO9001, etc.)
Various product lines that can be optimized according to the oral cavity and surgical situation
● Submerged type implant with an external hex connection
structure
● All RBM surface treatment (US plus) improves compatibility
between bone and soft tissue
● Can facilitate placement applicable to various bone quality
and obtain superior bonding stability
● Product line: USII, USIII, US Ultra Wide�
RBM
US System
OSSTEM Implant System Flow
● Hex 3.4mm external connection● Compatible with US wide abutment● Wide diameter fixture● Indication of US Ultra-Wide system
- Immediate placement at the extract socket
- Immediate replacement of the failed implant
● Increased osseointegration in the cortical bone● Expanded contact area with the bone● Decreased marginal bone loss● RBM surface treated for excellent
biocompatibility
● Increased osseointegration in the cortical bone● Expanded contact area with the bone● Decreased marginal bone loss● RBM surface treated for excellent
biocompatibility
US II US III
L: 8.5 10 11.5 13 15
US Ultra Wide�
L : 7 8.5 10 11.5 13 15
L: 8.5 10 11.5 13 15
L : 7 8.5 10 11.5 13 15
L : 7 8.5 10 11.5 13 15L : 7 8.5 10 11.5 13 15 L : 7 8.5 10 11.5 13
6.0
US
Sys
tem
US
Sys
tem
Hex Type
Abutment Diameter
Fixture Diameter
H
G / H
L
10 11
US
Sys
tem
US
Sys
tem
Torque Driver Extened Replacement Male
US Prothesis Library
System
UCLA
Cement
ER
ZioCera
Angled
Safe
Abutment
Esthetic
Esthetic-low
Standard
O - ring
Abutment Abutment Screw Impression Coping Lab Analog Temporary Abutment & Cylinder Polishing Protector
(Non-Hex)(Hex) (Hex)
(Non-Hex)(Hex)
Cement
(Ti)
(Ti)
(Ti)
(Ti)
ERZioCera/
ZioCera Angled
(Double Hex)(15°) (25°)
Angled
(Gold)
Abutment Protect Cap
Healing Cap
Gold Cylinder
O-rings System Dalbo System
Cylinder Screw
(Hex) (Non-Hex)
(Hex) (Non-Hex)
(Hex) (Non-Hex)
(Hex) (Non-Hex)
(Hex) (Non-Hex)
(Hex) (Non-Hex)
Pick-up
Transfer
Plastic Cylinder
(Non-Hex)(Hex)
(Plastic)
(Hex)
Pick-up Transfer
Transfer
Transfer
(Hex) (Non-Hex)
(Hex) (Non-Hex)
(Hex) (Non-Hex)
(Only UCLA Abutment)
Pick-up
(Non-Hex)
(Hex) (Non-Hex)
OSSTEM
US System
Cover Screw Headless Cover Screw Healing Abutment US II Fixture US III Fixture US Ultra-Wide�
LOCATOR
Pick-up
Replacement Male Extened Replacement Male
13
US
Sys
tem
12
US
Sys
tem
OS
MS
Ortho KIT(OOKS)
MS KIT(OMSK)
Guide Drill
Sidecut Drill
Parallel Pin
Hand Driver
Torque Driver SS Fixture
Driver
GS Fixture
Driver
No Mount
Driver
Removal Tool
for Mount
Drill Extension
Simple Open WrenchCortical Drill 3 Ratchet Wrench Depth Gauge
Long Shank Pilot Drill
US Long Shank
Countersink
SS Long Shank
Countersink
SS II Surgical TapUS II Surgical Tap
Simple Mount Extension
Simple Mount DriverTwist Drill
Cortical Drill 2
Surgical
US
SS
IIHanaro KIT(HKA2), Simple KIT(OSPK) Prosthetic KIT
(OPK)
Ridge Split KIT
(ORSSK/ORSOK)
Osteotome KIT(AOST)
Osteo KIT(OSTK)
Sinus KIT(ASLK)
Bone Spreader KIT
(OBSOK)
Prosthetic Etc
KIT for each system
IIIHanaro KIT(HKA2), Simple KIT(OSPK)
Taper KIT(OTSK), Taper Mini KIT(OGS3MK)
Ultra
II
III
Ultra
Ultra KIT(OUK)
Hanaro KIT(HKA2), Simple KIT(OSPK)
Hanaro KIT(HKA2), Simple KIT(OSPK)
Taper KIT(OTSK), Taper Mini KIT(OGS3MK)
Ultra KIT(OUK)
Surgical
GS
IIGS KIT(OGSK2), GS Mini KIT(OIKGM)
Hanaro KIT(HKA2)
Prosthetic KIT
(OPK)
GS Prosthetic
KIT(GSPK)
Ridge Split KIT
(ORSSK/ORSOK)
Osteotome KIT(AOST)
Osteo KIT(OSTK)
Sinus KIT(ASLK)
Bone Spreader KIT
(OBSOK)
Prosthetic Etc
KIT for each system
IIITaper KIT(OTSK), Taper Mini KIT(OGS3MK)
GS KIT(OGSK2), GS Mini KIT(OIKGM), Hanaro KIT(HKA2)
Ultra Ultra KIT(OUK)
OSSTEMIMPLANTSYSTEMUS SystemFixture and RestorativeComponents Early & Esthetic
OSSTEM IMPLANT
US System
17
US
Sys
tem
16
US
Sys
tem
Prosthetic Flow Diagrams for US SystemCement Retained Restoration : Cement Abutment, Angled Abutment, ZioCera, UCLA Abutment
Screw Retained Retoration : UCLA Abutment, ZioCera/ZioCera Angled Abutment
Screw & Cement Retained Restoration : ER Abutment ● Mini, Regular, Wide
Ti Screw
Polishing Protector
(Only UCLA Abutment)
1.2 Hex Driver(Mini Only : 0.9Hex Driver)
Cover Screw Healing Abutment 1.2 Hex Driver
ER AbutmentCement Abutment
(Short) (Long)
Fixture Pick-up Impression Coping
Fixture Transfer Impression Coping
(Double Hex) (Hex)
Angled Abutment
(Non-Hex)
UCLA Gold Abutment(Hex) (Non-Hex)(Hex)
(Non-Hex)(Hex)
(Non-Hex)(Hex)(Non-Hex)(Hex)Temporary AbutmentUCLA Plastic Abutment
Fixture Lab Analog
ZioCera/ZioCera
Angled Abutment
Fixture Lab Analog
Safe Abutment
1.2 Hex Driver(Mini Only : 0.9Hex Driver)
Cover Screw Healing Abutment 1.2 Hex Driver
(Short) (Long)
Fixture Pick-up Impression Coping
Fixture Transfer Impression Coping
(Non-Hex)(Hex)
Prosthetic Flow Diagrams for US SystemCement Retained Restortion : Safe Abutment ●Regular, Wide
Carrier Cap Protect Cap
34p36p
38p37p
50p
47p
30p
31p
47p 45p
50p
52p
52p 52p
30p31p
45p
50p
41p
51p
43p
26p 28p
US Ultra-Wide�
24p
US II US III
26p 28p
US Ultra-Wide�
24p
US II US III
19
US
Sys
tem
18
US
Sys
tem
Prosthetic Flow Diagrams for US SystemScrew Retained Restoration : Esthetic Abutment ● Regular
Esthetic
Polishing Protector
Esthetic
Lab Analog
Ti Screw
2.0 int. Hex Driver (Regular)
1.2 Hex Driver(Mini Only : 0.9Hex Driver)
Cover Screw Healing Abutment
1.2 Hex Driver
Esthetic Abutment Screw
Esthetic Abutment(Regular Only)
Esthetic Healing Cap
Prosthetic Flow Diagrams for US SystemScrew Retained Restoration : Esthetic-low Abutment ●Regular, Wide
Esthetic - low
Ti Screw
Cover Screw Healing Abutment
2.0 int.Hex Driver (Regular)
2.7 int.Hex Driver (Wide)
1.2 Hex Driver(Mini Only : 0.9Hex Driver)
1.2 Hex Driver
Esthetic-low Abutment Esthetic-low Healing Cap
Esthetic-low Transfer
Impression Coping
Esthetic-low
Polishing Protector
Esthetic-low
Lab Analog
Esthetic-low Abutment Screw
Esthetic
Temporary Cylinder
Esthetic Pick-up
Impression Coping
Esthetic
Transfer
Impression Coping
Esthetic Gold Cylinder Esthetic Plastic Cylinder Esthetic-low
Temporary Cylinder
Esthetic-low
Gold Cylinder
Esthetic-low
Plastic Cylinder
(Non-Hex)(Hex)
(Non-Hex) (Non-Hex)(Hex)(Hex)
(Non-Hex)(Hex) (Non-Hex)(Hex) (Non-Hex)(Hex) (Non-Hex)(Hex) (Non-Hex)(Hex)
Esthetic - low Pick-up
Impression Coping
54p
55p
55p
53p
30p31p
53p
55p
55p
58p
59p
59p
56p
30p31p
56p
58p
59p
57p 57p54p 54p
26p 28p
US Ultra-Wide�
24p
US II US III
26p 28p
US Ultra-Wide�
24p
US II US III
21
US
Sys
tem
20
US
Sys
tem
Prosthetic Flow Diagrams for US SystemScrew Retained Restoration : Standard Abutment ● Regular
Standard Temporary Cylinder
Standard
Polishing Protector Standard Lab Analog
Standard Gold Cylinder Standard Plastic Cylinder
Ti Screw
2.0 int.Hex Driver
1.2 Hex Driver(Mini Only : 0.9Hex Driver)
Cover Screw Healing Abutment
1.2 Hex Driver
Standard Abutment Screw
Standard Abutment(Regular Only)
Standard Healing Cap
Standard Pick-up
Impression Coping
Standard Transfer
Impression Coping
61p
62p
62p
61p
60p 60p
31p30p
62p
60p 61p
Prosthetic Flow Diagrams for US SystemOverdenture Restoration : O-ring / LOCATOR Abutment ●Regular
Cover Screw1.2 Hex Driver(Mini Only : 0.9Hex Driver)
1.2 Hex DriverHealing Abutment
30p 31p
O-ring Lab Analog LOCATOR Impression Coping
LOCATOR Lab Analog
O-ring Abutment Driver
(Low Retention)
(High Retention)
O-rings Retainer
Dalbo Plus Attachment
(for Laboratory)
(for Denture)
(Cap Type)
(Open Type)
O-ring System
Dalbo plus Screw Driver
Dalbo System
Block out Spacer & Denture Cap
Replacement Male Extended Replacement Male
Core Tool
Stud Abutment LOCATOR Abutment LOCATOR Torque Driver
64p
63p
63p
65p
63p
66p
67p
67p
67p
66p
66p 67p
26p24p
US II US III
26p24p
US II US III
22
US
Sys
tem
23
US
Sys
tem
● External hex-connected, submerged fixture
● Triple-tapered thread and double-tapered shape enable excellent initial bonding stability with soft bone
● Excellent precision fit with superstructure denture : looseness between fixture hex and
superstructure 7-15 , rotation looseness 0.4 -2
●Natural root-like shape enables immediate insertion upon extraction
● Tapered body shape minimizing damage to adjacent roots
● 3-bladed cutting edge with excellent self-tapping force
●Hybrid RBM surface facilitating plaque control
● A variety of diameters and lengths are available for various oral environments
● Limited insertion torque : 40Ncm
* We recommend that the fixture with over 4.5mm diameter is used for single case in Molar
Mini Platform ∅3.5
8.5 10 11.5 13 15
US II Fixture
Regular Platform ∅4.1
Wide Platform ∅5.1Features of US II Fixture
8.57.0 10 11.5 13 15
P ∅3.5
Hex 2.4
L D ∅3.3
7.0 -
8.5 BFM208A
10 BFM210A
11.5 BFM211A
13 BFM213A
15 BFM215A
P ∅4.1
Hex 2.7
L D ∅3.75 ∅4.0
7.0 BFR307A BFR407A
8.5 BFR308A BFR408A
10 BFR310A BFR410A
11.5 BFR311A BFR411A
13 BFR313A BFR413A
15 BFR315A BFR415A
P ∅5.1
Hex 3.4
L D ∅5.0 ∅5.5
7.0 BFW507A BFW607A
8.5 BFW508A BFW608A
10 BFW510A BFW610A
11.5 BFW511A BFW611A
13 BFW513A BFW613A
15 BFW515A BFW615A
8.57.0 10 11.5 13 15
Hex 1.2
Hex : 0.9 for Mini
1.2 for Regular & Wide
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
L
D
D
P
P
L
D
P
L
US II Fixture Order Code
Fixture Only
-Fixture : Product Code (ex : BFR307A)
Pre-Mounted Fixture (Simple Mount)
-Fixture + Simple Mount + Cover Screw : A + Fixture Product Code (ex : ABFR307A)
LRBM
D
Hex 2.4
Hex 2.7
Hex 3.4
※ The following labeled dimension may differ from the actual dimension.
24
US
Sys
tem
25
US
Sys
tem
※ The following labeled dimension may differ from the actual dimension.
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
● External hex-connected, submerged fixture
● Excellent precision fit with superstructure denture : looseness between fixture hex and
superstructure 7-15 , rotation looseness 0.4 -2
● Taper body offers excellent primary bonding
● Corkscrew thread & Cutting edge
- Powerful self threading
- Change path easily
- Increase insertion torque in soft bone
- Increase initial stability in soft bone
● A variety of diameters and lengths are available for various oral environments
● Limited insertion torque : 40Ncm
* We recommend that the fixture with over 4.5mm diameter is used for single case in Molar
US III Fixture
Features of US III Fixture
Hex 1.2
US III Fixture Order Code
Fixture Only
-Fixture : Product Code (ex : US3R4010R)
Pre-Mounted Fixture (Simple Mount)
-Fixture + Simple Mount + Cover Screw : A + Fixture Product Code (ex : AUS3R4010R)
L
Hex : 1.2 for Regular & Wide
D
Mini Platform ∅3.5
8.5 10 11.5 13 15
P ∅3.5
Hex 2.4
L D ∅3.5
7.0 -
8.5 US3M3508R
10 US3M3510R
11.5 US3M3511R
13 US3M3513R
15 US3M3515RD
L
Hex 2.4P
Regular Platform ∅4.1 P ∅4.1
Hex 2.7
L D ∅4.0 ∅4.5
7 US3R4007R US3R4507R
8.5 US3R4008R US3R4508R
10 US3R4010R US3R4510R
11.5 US3R4011R US3R4511R
13 US3R4013R US3R4513R
15 US3R4015R US3R4515R
P
L
Hex 2.7
Wide Platform ∅5.1 P ∅5.1
Hex 3.4
L D ∅5.0
7 US3W5007R
8.5 US3W5008R
10 US3W5010R
11.5 US3W5011R
13 US3W5013R
15 US3W5015R
8.57.0 10 11.5 13 15
8.57.0 10 11.5 13 15
L
Hex 3.4
Hex 2.7
Wide PS Platform ∅5.0 P ∅5.0
Hex 2.7
L D ∅4.5 ∅5.0
7 US3P4507R US3P5007R
8.5 US3P4508R US3P5008R
10 US3P4510R US3P5010R
11.5 US3P4511R US3P5011R
13 US3P4513R US3P5013P
15 US3P4515R US3P5015R
L
P
P
8.57.0 10 11.5 13 15
D
D
D
27
US
Sys
tem
26
US
Sys
tem
● External hex, wide-diameter fixture that commonly uses US wide abutment components
● A fixture that is convenient to use in case of immediate insertion following posterior tooth
extract socket and replacement of failed implants
● Looseness between fixture hex and superstructure : 7~15 Rotation looseness : 0.4°~ 2°
● Securing a platform switching effect that minimizes bone resorption and enhances soft tissue volume
● Optimized apex design that enables gaining stable initial fixation even at 3 mm below the extract socket
● All RBM surfaces with excellent bio-affinity
● 4-bladed cutting edge with excellent self-tapping force
● A variety of diameters and lengths are available for various oral environments
● Limited insertion torque : 40 Ncm
Platform ∅6.0
Hex 3.4
L D ∅7.0
7.0 BFW7007A
8.5 BFW7008A
10 BFW7010A
11.5 BFW7011A
13 BFW7013A
US Ultra-Wide� Fixture
Wide Diameter ∅6.0
Features of US Ultra-Wide fixture
( *Uses the same mount and cover screw with US Wide )
7.0 8.5 10 11.5 13
OSSTEM IMPLANT SYSTEMW Fixture Platform
L
D
US Ultra-Wide� Fixture Order Code
Fixture Only
- Fixture : Product Code (ex : BFW6008A)
Pre-Mounted Fixture (Simple Mount)
- Fixture + Simple Mount + Cover Screw : A + Fixture Product Code (ex : ABFW6008A)
Wide Diameter ∅7.0
7.0 8.5 10 11.5 13
L
D
Hex : 1.2
Hex : 1.2
1.2
Platform ∅5.1
Hex 3.4
L D ∅6.0
7.0 BFW6007A
8.5 BFW6008A
10 BFW6010A
11.5 BFW6011A
13 BFW6013A
D
RBM
※ The following labeled dimension may differ from the actual dimension.
29
US
Sys
tem
28
US
Sys
tem
Headless Cover Screw
Healing AbutmentMini Regular Wide
Code ESFMM ESFMR ESFMW
● Color indication facilitates the identification in the oral cavity
●Use a 1.2 hex driver to remove screws
● Packing unit : Mount + Mount Screw
● Tightening torque : 8-10 Ncm
●Use a 1.2 hex driver
● Packing unit : Healing abutment
● Tightening torque : 5-8 Ncm
●Use 0.9 (mini) and 1.2 (regular and wide) hex drivers
● Packing unit : Cover Screw
● Tightening torque : 5-8 Ncm
Mini Regular Wide
US HCM100 HCR100 HCW100
●Use for limited proximal space or suturing with deficient gingiva
●Use 0.9 (mini) and 1.2 (regular and wide) hex drivers
● Packing unit : Headless cover screw
● Tightening torque : 5-8 Ncm
Mini Regular Wide
Simple Mount
LD ∅6.0
2.0 -
3.0 TIHW603
4.0 -
5.5 TIHW605
7.0 -
LD ∅4.1 ∅5.0 ∅6.0
2.0 - AIHR502 AIHR602
3.0 AIHR403 AIHR503 AIHR603
4.0 - AIHR504 AIHR604
5.5 AIHR405 AIHR505 AIHR605
7.0 AIHR407 AIHR507 AIHR607
0.9 1.2
WideRegularMini
L
1.2
Regular
Wide PS
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
D
1.2
L
1.2
1.2
L
1.21.21.2
8.0
∅5.0∅4.1 ∅6.0
∅6.0
DD
Mini Regular Wide Wide PS
US AICM100 AICR100 AICW100 TICW100
Cover Screw
1.1 1.1 1.1
Mini Regular Wide
0.9 1.2 1.2
1.1
Wide PS
1.2
H D ∅4.0 ∅5.0
2.0 - -
3.0 AIHM403 AIHM503
4.0 - -
5.5 AIHM405 AIHM505
7.0 - -
Mini
1.2
∅4.0
H
1.2
D
1.1
∅5.0
H D ∅5.1 ∅6.0 ∅7.0
2.0 - AIHW602 AIHW702
3.0 AIHW503 AIHW603 AIHW703
4.0 - AIHW604 AIHW704
5.5 AIHW505 AIHW605 AIHW705
7.0 - - -
1.2
Wide
H
1.2
1.2
∅5.1 ∅6.0 ∅7.0
H
D
1.2
D
OSSTEM Implant SystemEarly & Esthetic OSSTEM IMPLANT
US SystemComponents Guide
ER
Cement
Angled
Safe
Esthetic
Esthetic-low
Standard
O-ring LOCATOR�
UCLA
Standard Cylinder
Esthetic Cylinder
Esthetic-low Cylinder
ZioCera
ZioCera Angled
33
US
Sys
tem
32
US
Sys
tem
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
●Use for making general cement-type prosthesis
● Gigival gold color for aesthetic effect
● Tapered body design facilitating prosthetic fit
● Cross-section design for the prevention of prosthesis rotation
●Use a 1.2 hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : Ti screw : 30Ncm
EbonyGold screw : 20Ncm(mini), 30Ncm(regular & wide)
Order code - Abutment + Ti screw : Product code + TH (ex : CAR525TH)
Mini
WIde
(∅6.0)
(∅7.0)
Wide PSRegularRegular
(∅5.0)
(∅6.0)
Cement Abutment - Cement Retained Restoration
D ∅4.0
H G/HType
Hex Non-Hex
1.0 - -
7.02.0 CAM427 CAM427N
3.0 - -
4.0 CAM447 CAM447N
Ti
EbonyGoldScrew
ASM200*
ASM200W
D ∅5.0 ∅6.0
H G/HType Hex Non-Hex Hex Non-Hex
1.0 CAR514 CAR514N - -
4.02.0 CAR524 CAR524N - -
3.0 CAR534 CAR534N - -
4.0 CAR544 CAR544N - -
1.0 CAR515 CAR515N CAR615 CAR615N
5.52.0 CAR525 CAR525N CAR625 CAR625N
3.0 CAR535 CAR535N CAR635 CAR635N
4.0 CAR545 CAR545N CAR645 CAR645N
1.0 CAR517 CAR517N - -
7.02.0 CAR527 CAR527N - -
3.0 CAR537 CAR537N - -
4.0 CAR547 CAR547N - -
ASW200*
ASW200W
D ∅6.0 ∅7.0
H G/HType
Hex Non-Hex Hex Non-Hex
1.0 CAW614 CAW614N - -
4.02.0 CAW624 CAW624N - -
3.0 CAW634 CAW634N - -
4.0 CAW644 CAW644N - -
1.0 CAW615 CAW615N CAW715 CAW715N
5.52.0 CAW625 CAW625N CAW725 CAW725N
3.0 CAW635 CAW635N CAW735 CAW735N
4.0 CAW645 CAW645N CAW745 CAW745N
H
G/H
D
H
G/H
D
H
G/H
D
Hex Non-Hex
Hex Non-Hex
Hex Non-Hex
Hex Non-Hex
H
G/H
D
H
G/H
D
Hex Non-Hex
H
G/H
D
Hex Non-Hex
H
G/H
D
Hex
R-TypeScrew
Ti
EbonyGold
ASR200*
ASR200W
D ∅6.0
H G/HType
Hex Non-Hex
1.0 - -
7.02.0 TCAW627 TCAW627N
3.0 - -
4.0 TCAW647 TCAW647N
Screw
RASW200*
RASW200W
D ∅6.0
H G/HType
Hex Non-Hex
1.0 - -
7.02.0 RCAW627 -
3.0 - -
4.0 RCAW647 -
Screw
ScrewTi
EbonyGold
Ti
EbonyGold
Ti
EbonyGold
1.2
1.2
1.2
1.2
1.2
1.2
1.2ASR200*
ASR200W
※ EbonyGold Screw : Can be purchased separately
35
US
Sys
tem
34
US
Sys
tem
US ZioCera Abutment
Angle G/H D ∅4.0
2.0 AAM4152C
4.0 AAM4154C
2.0 AAM4252C
4.0 AAM4254C
ASM200*
ASM200W
Mini
ScrewTi
EbonyGold
Ti
EbonyGold
Ti
EbonyGold
25°
15°
Angle G/H D ∅5.0
2.0 AAR5152C
4.0 AAR5154C
2.0 AAR5252C
4.0 AAR5254C
ASR200*
ASR200WScrew
25°
15°
Angle G/H D ∅6.0
2.0 AAW6152C
4.0 AAW6154C
2.0 AAW6252C
4.0 AAW6254C
ASW200*
ASW200WScrew
25°
15°
Angle G/H D ∅6.0
2.0 TAAW6152C
4.0 TAAW6154C
2.0 TAAW6252C
4.0 TAAW6254C
ASR200*
ASR200WScrew
Ti
EbonyGold
Ti
EbonyGold
25°
15°
Angle G/H D ∅6.0
2.0 RAAW6152C
4.0 RAAW6154C
2.0 RAAW6252C
4.0 RAAW6254C
RASW200*
RASW200WScrew
25°
15°
●Use for the path adjustment of prosthesis
● Gold color for aesthetic effect
● Double hex connection overcoming the limitation of the abutments’ direction
● Since screw loosening occurs somewhat frequently, EbonyGold screw is recommended
●Use a 1.2 hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : Ti screw : 30Ncm
EbonyGold screw : 20Ncm(mini), 30Ncm(regular & wide)
Order code - Abutment + Ti screw : Product code + TH (ex : AAR5152CTH)
Angled Abutment - Cement Retained Restoration
15° 25°
Regular
15° 25°
Wide
15°
15°
25°
Wide PS
25°
R-Type
15° 25°
G / H
G / H
G / H
G / H
G / H
D
D
D
D
D
OSSTEM IMPLANT SYSTEM
1.2
1.2
1.2
1.2
1.2
H G/HD ∅5.0
3.0 ZAM537
5.0 ZAM557
ASM200*
ASM200W
Mini
ScrewTi
EbonyGold
7.0
H G/H D ∅5.0 ∅6.0
3.0 ZAR537 ZAR637
5.0 ZAR557 ZAR657
ASR200*
ASR200WScrew
Ti
EbonyGold
7.0
●Use for esthetic implant restorations
● Ivory color for esthetic shade
● Applicable as a screw retained by direct build up.
●Use a 1.2 hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : Ti screw : 30Ncm
EbonyGold screw : 20Ncm(mini), 30Ncm(regular and wide)
Order code - Abutment + Ti Screw : Product Code + TH (ex : ZAR537TH)
ZioCera Abutment - Cement or Screw Retained Restoration
∅5.0
∅6.0
∅5.0
Regular
G / H
H
G / H
H
D
D
G / H
H
D
1.2
1.2
1.2
Hex
3.0
Hex
5.0
Hex
3.0
Hex
5.0
Hex
3.0
Hex
5.0
※ EbonyGold Screw : Can be purchased separately ※ EbonyGold Screw : Can be purchased separately
37
US
Sys
tem
36
US
Sys
tem
UCLA Abutment Components
Type D ∅4.0
Hex GCM200
Non-Hex GCM100
Ti ASM200*
EbonyGold ASM200W
●Use for cases with path and aesthetic and spatial constraints
● After customization, be sure to use only dental gold alloy for casting to make the prosthesis
●Melting point range of abutment (Au, Pt, Pd alloy) : 1400-1450° (use of non-precious metal alloy for casting prohibited)
●Use a 1.2 hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : Ti screw : 30Ncm
EbonyGold screw : 20Ncm(mini), 30Ncm(regular & wide)
Order code - Abutment + Ti Screw : Product Code + TH (ex : GCR200TH)
Screw
Type D ∅4.5
Hex GCR200
Non-Hex GCR100
Ti ASR200*
EbonyGold ASR200WScrew
Mini
Hex Non-Hex
Regular
UCLA Gold Abutment - Screw or Cement Retained Restoration
Hex Non-Hex
12
D
12
D
1.2
1.2
US ZioCera Angled Abutment
●Used for the esthetic prosthesis (Zirconia)
● Ivory color similar to a natural tooth
● The use of direct build-up method enables the screw restoration
● The diameter which is useful and margin forms which are possible to modify
●Used for the path adjustment of anterior in case of 17。axial angle
●Use the 1.2 hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : 30Ncm (regular)
Order code - Abutment + Ti screw : Product Code + TH (ex : ZAAR5173TH)
ZioCera Angled abutment - Cement or Screw Retained Restoration
H G/H D ∅5.5 ∅6.5
3.0 ZAAR5173 -
4.0 - ZAAR6174
ASR200*
ASR200WScrew
Ti
EbonyGold
9.0
∅5.5 ∅6.5
Regular
1.2
Hex
G/H 3.0
Hex
G/H 4.0
G / H
H
17�
D
※ EbonyGold Screw : Can be purchased separately
※ EbonyGold Screw : Can be purchased separately
39
US
Sys
tem
38
US
Sys
tem
1.2
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
Type D ∅4.0
Hex PSM200
Non-Hex PSM100
ASM200
●Use for cases with path and aesthetic and spatial constraints
● After customization, dental alloy (gold, non-precious metal) is used for casting
● Lower precision in the joints compared to UCLA Gold Abutments
●Use a 1.2 hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : 30Ncm
Order code - Abutment + Ti Screw : Product Code + TH (ex : PSR200TH)
Ti Screw
Type D ∅4.5
Hex PSR200
Non-Hex PSR100
ASR200Ti Screw
Mini
UCLA Plastic Abutment - Screw or Cement Retained Rstoration
Non-Hex Hex
Regular
Non-Hex Hex
D
12
D
12
1.2
Type D ∅5.5
Hex TGCW200
Non-Hex TGCW100
Ti ASR200*
EbonyGold ASR200WScrew
Type D ∅5.5
Hex RGCW200
Non-Hex RGCW100
Ti RASW200*
EbonyGold RASW200WScrew
Non-Hex Hex
Non-Hex Hex
Wide PS
R-Type
D
12
D
12
Type D ∅5.5
Hex GCW200
Non-Hex GCW100
Ti ASW200*
EbonyGold ASW200WScrew
Wide
Hex Non-Hex
12
D
1.2
1.2
1.2
41
US
Sys
tem
40
US
Sys
tem
●Use to make temporary prothesis (material : Ti Gr-3)
● Easy to customize, designed to minimize indication constraints
●Use a 1.2 hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : 15Ncm
Order code - Abutment + Ti Screw : Product Code + TH (ex : TAR200TH)
Hex Non-Hex
Regular
UCLA Temporary Abutment - Temporary Restoration
Type D ∅4.0
Hex TAM200
Non-Hex TAM100
ASM200Ti Screw
Type D ∅4.5
Hex TAR200
Non-Hex TAR100
ASR200Ti Screw
Mini1.2
Hex Non-Hex
1.2
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
D
12
D
12
1.2Type D ∅5.5
Hex PSW200
Non-Hex PSW100
ASW200Ti Screw
Type D ∅5.5
Hex TPSW200
Non-Hex TPSW100
ASR200Ti Screw
Type D ∅5.5
Hex RPSW200
Non-Hex RPSW100
RASW200Ti Screw
Wide
Wide PS
R-Type
Non-Hex Hex
Non-Hex Hex
Non-Hex Hex
D
12
12
D
D
12
1.2
1.2
43
US
Sys
tem
42
US
Sys
tem
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
Type D ∅4.0
13.5Hex ICPM402L
LNon-Hex ICPM401L
10.5Hex ICPM402S
Non-Hex ICPM401S
● Transfer type for taking an impression using a ready-made tray
● Triangular arc ( ) design improves markability following impression
● Long and short types enhance convenience
● The hex type is designed as a two-piece, and the non-hex type, as a one-piece
● Packing unit : Impression Coping body + Guide Pin (Hex)
Impression Coping (Non-Hex)
Mini
Fixture Transfer Impression Coping
Hex Non-Hex
Regular
Wide
D
L
Hex Non-Hex
D
L
Hex Non-Hex
D
L
Type D ∅5.0
13.5Hex ICPR502L
LNon-Hex ICPR501L
10.5Hex ICPR502S
Non-Hex ICPR501S
Type D ∅6.0
13.5Hex ICPW602L
LNon-Hex ICPW601L
10.5Hex ICPW602S
Non-Hex ICPW601S
Wide
Wide PS
Type D ∅5.5
Hex TAW200
Non-Hex TAW100
ASW200Ti Screw
Type D ∅5.5
Hex TTAW200
Non-Hex TTAW100
ASR200Ti Screw
Hex Non-Hex
1.2
Hex Non-Hex
1.2
R-Type Type D ∅5.5
Hex RTAW200
Non-Hex RTAW100
RASW200Ti Screw
1.2
D
12
Hex Non-Hex
D
D
12
12
45
US
Sys
tem
44
US
Sys
tem
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
Type D ∅4.0
Hex ICFM400
Non-Hex ICFM400N
10 -
15 CSM150
17 -
● Pick-up type for taking an impression using a customized tray
● Impression coping designed with Hole-in-one ; no need for resin fixation
● Asymmetrical structure minimizing contact interference ( )
● Long and short types enhance convenience
● Packing unit : Impression Coping body + Guide Pin
Guide Pin (L)
Type D ∅6.0
Hex ICFW600
Non-Hex ICFW600N
10 CSW100
15 CSW150*
17 -
Guide Pin (L)
Guide Pin (L)
Hex
Non-Hex
Mini
Regular
Wide
Fixture Pick-Up Impression Coping - Long
Hex Non-Hex
L
1.2
Hex Non-Hex
Hex Non-Hex
1.2
L
1.2
L
∅5.0
ICFR500
ICFR500N
CSR100
CSR150*
CSR170
∅6.0
ICFR600
ICFR600N
10
15
17
Type D
D
D
D
12
12
12
Wide PS
R-Type
Hex Non-Hex
D
L
Hex Non-Hex
D
L
Type D ∅6.0
L13.5 Hex TICPW602
10.5 Non-Hex TICPW601
Type D ∅6.0
L13.5 Hex RICPW602
10.5 Non-Hex RICPW601
47
US
Sys
tem
46
US
Sys
tem
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
Type D ∅5.0
Hex ICSR500
Non-Hex ICSR500N
10 CSR100*
15 CSR150
17 CSR170
● Pick-up type for taking an impression using a customized tray
● Impression coping designed with Hole-in-one ; no need for resin fixation
● Asymmetrical structure minimizing contact interference ( )
● Long and short types enhance convenience
● Packing unit : Impression Coping body + Guide Pin
Guide Pin (L)
Type D ∅6.0
Hex ICSW600
Non-Hex ICSW600N
10 CSW100*
15 CSW150
17 -
Guide Pin (L)
Regular
Fixture Pick-Up Impression Coping - Short
Non-Hex Hex
Wide
1.2
L
Hex Non-Hex
1.2
L
D
7
D
7
Type D ∅6.0
Hex TICFW600
Non-Hex TICFW600N
10 -
15 TCSW150
17 -
Guide Pin (L)
Type D ∅6.0
Hex RICFW600
Non-Hex RICFW600N
10 -
15 RCSW150
17 -
Guide Pin (L)
Wide PS
R-Type
Hex Non-Hex
1.2
L
1.2
L
Hex Non-Hex
D
12
D
12
49
US
Sys
tem
48
US
Sys
tem
Mini
Regular
Wide
Wide PS
H G/H D ∅5.0 ∅6.0
1.0
2.0
3.0
4.0
1.0
2.0
3.0
4.0
1.0
2.0
3.0
4.0
ERAR514C -
ERAR524C -
ERAR534C -
ERAR544C -
ERAR515C ERAR615C
ERAR525C ERAR625C
ERAR535C ERAR635C
ERAR545C ERAR645C
ERAR517C -
ERAR527C -
ERAR537C -
ERAR547C -
4.0
5.5
7.0
H G/H D ∅6.0 ∅7.0
1.0
2.0
3.0
4.0
1.0
2.0
3.0
4.0
ERAW614C -
ERAW624C -
ERAW634C -
ERAW644C -
ERAW615C ERAW715C
ERAW625C ERAW725C
ERAW635C ERAW735C
ERAW645C ERAW745C
4.0
5.5
H G/HD ∅4.0
1.0 -
2.0 ERAM427C
3.0 -
4.0 ERAM447C
ASM200*
ASM200W
7.0
4.0 5.5
7.0
7.0
7.0
4.0
●Use for creating combination-type prosthesis with excellent retrievability
●Unique connection structure carrying the advantage
of both hex and non-hex types (maximum path compensation of 60 )
● Gingival gold color for aesthetic effect
● Tapered body design facilitating prosthetic fit
● Cross-section design for the prevention of prosthesis rotation
●Use a 1.2 hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque :
Ti screw : 30Ncm
EbonyGold screw : 20Ncm(mini), 30Ncm(regular and wide)
Order code - Abutment + Ti Screw : Product Code + TH
(ex : ERAR525CTH)
ER Abutment - Screw & Cement Retained Restoration
5.5
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
D
G / H
H
G / H
H
G / H
H
D
D
D
G/H
H
ScrewTi
EbonyGold
Ti
EbonyGold
Ti
EbonyGold
H G/HD ∅6.0
1.0 -
2.0 TERAW627C
3.0 -
4.0 TERAW647C
ASR200*
ASR200W
7.0
Screw
Screw
Screw
ASR200*
ASR200W
ASW200*
ASW200W
Cement Abutment ER Abutment
Ti
EbonyGold
1.2
1.2
1.2
1.2
Mini FAM300
Regular FAR300
Wide FAW300
Wide PS TFAW300
R-Type RFAW300
● Oral fixtures are built on the working model
● Packing unit : Lab analog
Mini UPCM100
Regular UPCR100
Wide UPCW100
Wide PS TUPCW100
R-Type RUPCW100
● For polishing upon prosthetic casting, use to avoid damaging the cylinder joint
● Packing unit : Polishing protector
Fixture Lab Analog
UCLA Polishing Protector
Mini Regular Wide Wide PS R-Type
Mini Regular Wide Wide PS R-Type
2.4 2.7 3.4 2.7 3.3
※ EbonyGold Screw : Can be purchased separately
51
US
Sys
tem
50
US
Sys
tem
Esthetic Abutment Components
●Use for making aesthetic screw-retained prosthesis
● Designed to make the prosthesis onto a cylinder following abutment
connection in the oral cavity
●Maximum path compensation of 30
●Use a 2.0 internal hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : 30Ncm
Order code - Abutment + Ti screw : Product code + TH (ex : EAR200TH)
Esthetic Abutment - Screw Retained Restoration
●Use for the protection of aesthetic abutments in the oral cavity and to
minimize the patient's discomfort
●Use a 1.2 hex driver
● Packing unit : Healing cap
● Tightening torque : 20 Ncm
Esthetic Healing Cap
Regular
Regular
GH D ∅4.8
1.0 EAR100
2.0 EAR200
3.0 EAR300
4.0 EAR4002.0
1.2
H D ∅4.8
6.0 EHC100
D
D
H
G / H
1.8H G/H D ∅4.8
1.0 SFAR514SC
4.0 2.5 SFAR524SC
4.0 SFAR544SC
1.0 SFAR515SC
5.5 2.5 SFAR525SC
4.0 SFAR545SC
1.0 SFAR517SC
7.0 2.5 SFAR527SC
4.0 SFAR547SC
5.5 7.0
Regular
H G/H D ∅6.0
1.0 SFAW614SC
4.0 2.5 SFAW624SC
4.0 SFAW644SC
1.0 SFAW615SC
5.5 2.5 SFAW625SC
4.0 SFAW645SC
1.0 -
7.0 2.5 -
4.0 -
Wide
●Use for making single prosthesis to prevent screw loosening
● Oval-shaped abutment body prevents prosthesis rotation
● Screw loosening is prevented, since screws are fixed to the
prosthesis
● Gingival gold color for aesthetic effect
●Use a 1.2 hex driver
● Packing unit : Abutment + Ti screw + carrier cap + protect cap
● Tightening torque : 30 Ncm
Safe Abutment - Cement Retained Restoration
4.0
4.0 5.5
G / H
H
D
G / H
H
D
Circle
Ellipse
section
53
US
Sys
tem
52
US
Sys
tem
● Preliminary impression copings exclusively for aesthetic abutments
● Transfer type for taking an impression using a ready-made tray
● Packing unit : Impression coping
● Final impression copings exclusively for aesthetic abutments
● Pick-up type for taking an impression using a customized tray
● Impression coping designed with Hole-in-one ; no need for resin fixation
● Asymmetrical structure minimizing contact interference ( )
● Packing unit : Impression coping body + Guide Pin
● For polishing upon prosthetic casting, use to avoid damaging the cylinder joint
● Packing unit : Polishing protector
Regular
Type D ∅4.8
Hex ESR200
Non-Hex ESR100
10 GP100
15 GP150*
17 GP170
20 GP200
Guide Pin (L)
Regular
Esthetic Transfer Impression Coping
Esthetic Pick-up Impression Coping
Regular
Esthetic Lab Analog
Regular
Esthetic Polishing Protector
Hex Non-Hex
Regular ERR300
Regular EPCR100
●Make aesthetic oral abutments on the working modek
● Packing unit : Lab analog
L
8.0
H
H D ∅4.8
8.0 ETR100
1.2
D
D
● After customization, be sure to use only dental gold alloy for casting to
make the prosthesis
●Melting point range of cylinder (Au, Pt, Pd Alloy): 1400 - 1450。C
(use of non-precious metal alloy for casting prohibited)
●Use a 1.2 hex driver
● Packing unit : Cylinder + EbonyGold screw
Cylinder + Ti screw
● Tightening torque : 20 Ncm
Order code - Cylinder + EbonyGold screw : Product code + WH (ex : EGC200WH)
- Cylinder + TI screw : Product code + TH (ex : EGC200TH)
●Use for creating temporary prosthesis for aesthetic abutments
(material : Ti Gr-3)
● Easy to customize : designed to minimize indication constraints
●Use a 1.2 hex driver
● Packing unit : Cylinder + Ti screw
● Tightening torque : 15Ncm
Order code - Cylinder + Ti screw : Product code + TH (ex : ETT200TH)
● After customization, dental alloy (gold, non-precious metal) is used for
casting
● The precision of the connection part is lower compared to gold cylinders
●Use a 1.2 hex driver
● Packing unit : Cylinder + Ti screw
● Tightening torque : 20Ncm
Order code - Cylinder + Ti screw : Product code + TH (ex : EPS200TH)
Type D ∅4.8
Hex EGC200
Non- Hex EGC100
Ti Screw TS200*
TS200WEbonyGold Screw
Type D ∅4.8
Hex EPS200
Non-Hex EPS100
TS200Ti Screw
Type D ∅4.8
Hex ETT200
Non-Hex ETT100
TS200Ti Screw
Regular
Esthetic Gold Cylinder
Non-Hex Hex
Hex Non-Hex
Regular
Esthetic Plastic Cylinder
Regular
Esthetic Temporary Cylinder
1.2
1.2
D
12
Hex Non-Hex
D
12
1.2
D
12
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
55
US
Sys
tem
54
US
Sys
tem
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
Regular
Type D ∅4.8
Hex MGR200
Non-Hex MGR100
Ti Screw MTS200*
MTS200W
● After customization, be sure to use only dental gold alloy for casting to
make the prosthesis
●Melting point range of cylinder (Au, Pt, Pd Alloy) : 1400 - 1450。C
(use of non-precious metal alloy for casting prohibited)
●Use a 1.2 hex driver
● Packing unit : Cylinder + EbonyGold screw
Cylinder + Ti screw
● Tightening torque : 20 Ncm
Order code - Cylinder + EbonyGold screw : Product code + WH(ex : MGR200WH)
- Cylinder + Ti screw : Product code + TH(ex : MGR200TH)
EbonyGold Screw
Wide Wide PS
Type D ∅5.5
Hex MGW200
Non-Hex MGW100
Ti Screw WTS200*
WTS200WEbonyGold Screw
Regular
Regular
Esthetic-low Gold Cylinder
Non-Hex Hex
Non-Hex Hex
Wide | Wide PS
Regular
Type D ∅4.8
Hex MEPR200
Non-Hex MEPR100
MTS200Ti Screw
● After customization, dental alloy (gold, non-precious metal) is used for
casting
● The precision of the connection part is lower compared to gold cylinders
●Use a 1.2 hex driver
● Packing unit : Cylinder + Ti screw
● Tightening torque : 20 Ncm
Order code - Cylinder + Ti screw : Product code + TH (ex : MEPR200TH)
Wide Wide PS
Type D ∅5.5
Hex MEPW200
Non-Hex MEPW100
WTS200Ti Screw
Esthetic-low Plastic Cylinder
Wide I Wide PS
1.2
1.2
1.2
1.2
D
Non-Hex Hex
D
D
Non-Hex Hex
D
12
12
Esthetic-low Abutment Components
Regular Wide | Wide PS
Esthetic-low Healing Cap
●Use in case of small gap with antagonist teeth due to the smaller height
compared to aesthetic abutments
●Maximum path compensation of 48。
●Use 2.0 (regular) and 2.7 (wide) internal hex drivers
● Packing unit : Abutment + Ti screw
● Tightening torque : 30 Ncm
Order code - Abutment + Ti screw : Product code + TH (ex : MER200TH)
●Use for the protection of aesthetic low abutments in the oral cavity and to
minimize the patient's discomfort
●Use a 1.2 hex driver
● Packing unit : Healing cap
● Tightening torque : 20 Ncm
Esthetic-low Abutment- Screw Retained Restoration
Regular Wide Wide PS
G/H D ∅4.8 ∅5.5
1.0 MER100 MEW100 TMEW100
2.0 MER200 MEW200 TMEW200
3.0 MER300 MEW300 TMEW300
4.0 MER400 MEW400 TMEW4002.0
1.2 1.2
Regular Wide Wide PS
G/H
D
2.7 2.7
D
H
H D
4.6
Regular
∅4.8
MHCR100
Wide Wide PS
∅6.0
MHCW100
※ EbonyGold Screw : Can be purchased separately
57
US
Sys
tem
56
US
Sys
tem
●Make aesthetic oral abutments on the working model
● Packing unit : Lab analog
Regular
Type D ∅4.8
Hex MSR200
Non-Hex MSR100
10 GP100
15 GP150*
17 GP170
20 GP200
Guide Pin (L)
● Final impression copings exclusively for aesthetic low abutments
● Pick-up type for taking an impression using a customized tray
● Impression coping designed with Hole-in-one ; no need for resin fixation
● Asymmetrical structure minimizing contact interference ( )
● Packing unit : Impression coping body + Guide Pin
Wide Wide PS
Type D ∅5.5
Hex MSW200
Non-Hex MSW100
10 GPW100
15 GPW150*
17 -
20 -
Guide Pin (L)
Regular
Esthetic-low Pick-up Impression Coping
Regular
Esthetic-low Polishing Protector
Wide
Regular Wide | Wide PS
Esthetic-low Lab Analog
● For polishing upon prosthetic casting, use to avoid damaging the cylinder joint
● Packing unit : Polishing protector
Wide | Wide PS
Regular MPCR100
Wide | Wide PS MPCW100
Regular MERR300
Wide | Wide PS MERW300
Hex Non-Hex
L
L
Hex Non-Hex
8.0
D
8.0
D
1.2
1.2
Esthetic-low Temporary Cylinder
Esthetic-low Transfer Impression Coping
Regular
●Use for creating temporary prosthesis for aesthetic low abutments
(material : Ti Gr-3)
● Easy to customize : designed to minimize indication constraints
●Use a 1.2 hex driver
● Packing unit : Cylinder + Ti screw
● Tightening torque : 15Ncm
Order code - Cylinder + Ti Screw : Product Code + TH (ex : MTR200TH)
Regular Wide | Wide PS
Wide | Wide PS
Hex Non-Hex
Wide Wide PS
Type D ∅6.0
Hex MTW200
Non-Hex MTW100
WTS200Ti Screw
12
12
● Preliminary impression copings exclusively for aesthetic low abutments
● Transfer type for taking an impression using a ready-made tray
● Packing unit : Impression coping
H D
8.0
Regular
∅4.8
MTTR100
Wide Wide PS
∅5.5
MTTW100
H
D
1.2
1.2
Regular
Type D ∅5.3
Hex MTR200
Non-Hex MTR100
Ti Screw MTS200
Hex Non-Hex
D
D
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
59
US
Sys
tem
58
US
Sys
tem
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
●Use for creating temporary prosthesis for standard abutments
(material : Ti Gr-3)
● Easy to customize : designed to minimize indication constraints
●Use a 1.2 hex driver
● Packing unit : Cylinder + Ti screw
● Tightening torque : 15Ncm
Order code - Cylinder + Ti Screw : Product Code + TH (ex : STT100TH)
● Preliminary impression copings exclusively for standard abutments
● Transfer type for taking an impression using a ready-made tray
● Packing unit : Impression coping
Regular
Standard Temporary Cylinder
Regular
Standard Transfer Impression Coping
● After customization, dental alloy (gold, non-precious metal) is used for
casting
● The precision of the connection part is lower compared to gold cylinders
●Use a 1.2 hex driver
● Packing unit : Cylinder + Ti screw
● Tightening torque : 20 Ncm
Order code - Cylinder + Ti screw : Product code + TH (ex : SPS100TH)
Regular
Standard Plastic Cylinder H D ∅4.5
12 SPS100
TS200Ti Screw
H D ∅5.3
12 STT100
TS200Ti Screw
D
H
D
H
D
H
H D ∅4.5
8.0 STR100
1.2
1.2
Standard Abutment Components
●Use for making a hybrid denture or a bridge requiring hygiene control
●More advantageousfor oral hygiene due to the design of the prosthesis for
the upper gingiva
●Use a 2.0 internal hex driver
● Packing unit : Abutment + Ti screw
● Tightening torque : 30 Ncm
Order code - Abutment + Ti screw : Product code + TH (ex : SAR300TH)
●Use for the protection of standard abutments in the oral cavity and to
minimize the patient's discomfort
●Use a 1.2 hex driver
● Packing unit : Healing cap
● Tightening torque : 20 Ncm
● After customization, be sure to use only dental gold alloy for casting to make
the prosthesis
●Melting point range of cylinder (Au, Pt, Pd Alloy) : 1400 - 1450。C
(use of non-precious metal alloy for casting prohibited)
●Use a 1.2 hex driver
● Packing unit : Cylinder + EbonyGold screw
Cylinder + Ti screw
● Tightening torque : 20 Ncm
Order code - Cylinder + EbonyGold screw : Product code + WH(ex : SGC300WH)
- Cylinder + Ti screw : Product code + TH(ex : SGC300TH)
Standard Abutment - Screw Retained Restoration
Regular
Standard Healing Cap
Regular
Standard Gold Cylinder
H D ∅4.5
3.0 SAR300
4.0 SAR400
5.5 SAR550
7.0 SAR700
8.5 SAR850
H D ∅4.5
1.0 SGC300
2.0 SGC400
Ti Screw SGC400
TS200WEbonyGold Screw
H
H
Hex 1.2
Hex 2.0
D
H D ∅4.5
3.5 SHC100
D
H
D
1.2
Regular
※ EbonyGold Screw : Can be purchased separately
61
US
Sys
tem
60
US
Sys
tem
O-ring System
●Use for making stud-type overdenture
● O-ring components
For lab use : Black color
For denture : Yellow color (4N), orange color (6N)
● Compensate the retention force through O-ring replacement
●Maximum path compensation of 20。
●Use an O-ring abutment driver
● Packing unit : Abutment + Retainer Cap + O-rings
● Tightening torque : 30 Ncm
O-ring Abutment Set (O-ring Set)Overdenture Restoration
G/H D ∅5.0
2.0 OAA200S
3.0 OAA300S
4.0 OAA400S
5.0 OAA500S
6.0 OAA600S
●Use for making stud-type overdenture
● Superior stability of retention force vs. O-ring
● Dalbo plus attachment components
Housing (Ti) + Internal lamella (gold alloy)
Duplicate aid (plastic)
● Compensate the retention force through internal lamella rotation
(clockwise) using a special-purpose driver
●Maximum path compensation of 20
●Use an O-ring abutment driver
● Packing unit : Abutment + Dalbo plus attachments
● Tightening torque : 30 Ncm
O-ring Abutment Set (Dalbo Set)Overdenture Restoration
G/H D ∅5.0
2.0 OAA200D
3.0 OAA300D
4.0 OAA400D
5.0 OAA500D
6.0 OAA600D
D
G / H
D
G / H
● Final impression copings exclusively for standard abutments
● Pick-up type for taking an impression using a customized tray
● Impression coping designed with Hole-in-one ; no need for resin fixation
● Asymmetrical structure minimizing contact interference ( )
● Packing unit : Impression coping body + Guide Pin
Regular
Standard Pick-up Impression Coping H D ∅4.5
8.0 SSR100
10 GP100
15 GP150*
17 GP170
20 GP200
Guide Pin (L)
●Make aesthetic oral abutments on the working model
● Packing unit : Lab analog
● For polishing upon prosthetic casting, use to avoid damaging the cylinder joint
● Packing unit : Polishing protector
Regular SRR300
Regular SPCR100
Regular
Standard Lab Analog
Regular
Standard Polishing Protector
LH
1.2
D
● Packing unit : Only abutment
O-ring AbutmentOverdenture Restoration
G/H D ∅5.0
2.0 OAA200
3.0 OAA300
4.0 OAA400
5.0 OAA500
6.0 OAA600
D
G / H
63
US
Sys
tem
62
US
Sys
tem
● O-ring for making the overdenture used in laboratories
● Packing unit : O-rings 5 piece
O-ring Set (for Laboratory) Code OAO100S
● Oral O-ring with low retention force (approximately 4N)
● Packing unit : O-rings 5 piece
O-ring Set (Low Retention) Code OAO400S
● Oral O-ring with high retention force (approximately 6N)
● Packing unit : O-rings 5 piece
O-ring Set (High Retention) Code OAO600S
●Make oral O-ring abutments on the working model
● Packing unit : Lab analog
O-ring Lab Analog Code OAL
OSSTEM IMPLANT SYSTEMM R W Fixture Platform
● Selective application through 2 types of O-ring retention force
● Excellent retention force and good sense of denture placement
● Packing unit : Retainer cap + O-rings
Retainer Cap Set Code OARCS
●More advantageous for smaller occlusal gap compared to a retainer cap
● Packing unit : Retainer + O-rings
Retainer Set Code OARS
65
US
Sys
tem
64
US
Sys
tem
● Packing Unit : Locator Male Processing Kit (2 Set)
● Consist of
-Block out Spacer/Denture Cap connected Black Processing Male
-Replacement Male Blue/Pink/Clear
●Male Change by Locator Core Tool
Code LMPS
LOCATOR� Components
HU LOCATOR� AbutmentOverdenture Restoration
LOCATOR� Male Processing Kit
D
1.5mm
G/H● Packing unit : Locator abutment
● Stable dual retention & optimal holding capabilities against various
retention forces (6N, 12N, 22N)
● Excellent durability
● Possible denture restorations even at small vertical dimension
● Accommodate up to 40�divergence between two implants
● Retention males can be easily placed & removed with core tool
● Tightening torque : 30Ncm
● Can be used in US system & HU system
G/H D ∅3.5 ∅4.0
1 HULCA3510M HULCA4010R
2 HULCA3520M HULCA4020R
3 HULCA3530M HULCA4030R
4 HULCA3540M HULCA4040R
5 HULCA3550M HULCA4050R
● Packing Unit : Blue Replacement Male (4ea)
● retention Force : about 6N
● 0�~20�divergence (between two implants)
Code LRM06S
● Packing Unit : Pink Replacement Male (4ea)
● retention Force : about 12N
● 0�~20�divergence (between two implants)
Code LRM12S
● Packing Unit : clear Replacement Male (4ea)
● retention Force : about 22N
● 0�~20�divergence (between two implants)
Code LRM22S
LOCATOR� Replacement Male
● Packing Unit : Red Extended Replacement Male (4ea)
● retention Force : about 6N
● 20�~40�divergence (between two implants)
Code LEM06S
● Packing Unit : Green Extended Replacement Male (4ea)
● retention Force : about 12N
● 20�~40�divergence (between two implants)
Code LEM12S
LOCATOR� Extended Replacement Male
● Packing Unit : black processing Male (4ea)
● for lab. process
Code LBPSLOCATOR� Black Processing Male
● Packing Unit : Locator Block out spacers (20ea)
● For Space Sealing between Locator Abutment & Denture Cap
Code LBSSLOCATOR� Block out spacers
● Packing Unit : Locator Impression Coping (4ea)
● For Abutment level impression
Code LICSLOCATOR� Impression Coping
● Packing Unit : Locator lab Analog (4ea)
LAL40S
LAL50SCode
LOCATOR� lab Analog
● Packing Unit : Locator Torque Driver
● For tightening of Locator Abutment
● Select the Short/Long length
LOCATOR� Torque Driver
● Packing Unit : Locator Core Tool
● foe handling of locator system
Code LCCTLOCATOR� Core Tool
Type Short Long
Code TWLDS TWLDL