concept series panels - doc.spdirect.netdoc.spdirect.net/files/all concept series horizontal...

27
CSH-01 INDEX CSH-02 STANDARD PANEL OFFERING CSH-03 SIDE LAP DETAILS CSH-04 WALL SECTIONS CSH-05 WALL SECTIONS CSH-06 WALL SECTIONS CSH-07 BASE DETAILS CSH-08 PARAPET DETAIL CSH-09 VERTICAL REVEALS CSH-10 VERTICAL REVEALS CSH-11 END LAP DETAIL CSH-12 HEAD OPENING DETAILS CSH-13 HEAD OPENING DETAILS CSH-14 JAMB OPENING DETAILS CSH-15 SILL OPENING DETAILS CSH-16 SILL OPENING DETAILS CSH-17 HEAD, JAMB, SILL INTERSECTION-EXTRUSION CSH-18 HEAD, JAMB, SILL INTERSECTION-FLASHINGS CSH-19 END WALL DETAILS CSH-20 SOFFIT DETAILS CSH-21 OUTSIDE CORNER DETAILS CSH-22 INSIDE CORNER DETAILS CSH-23 OUTSIDE AND INSIDE CORNERS - MICROSEAM CSH-24 4 CORNER INTERSECTION CSH-25 PENETRATION (1 of 3) CSH-26 PENETRATION (2 of 3) CSH-27 PENETRATION (3 of 3) INDEX ELEVATION FOR DETAIL REFERENCE ONLY 23 7 3 8 20 SOFFIT 15 14 12 24 OPENING 19 25 26 23 OUTSIDE CORNER INSIDE CORNER 10 18 4 5 6 4 5 6 13 16 21 11 17 9 END WALL 27 22 NOTE: DETAILS ARE FOR PROMOTIONAL USE ONLY. FOR COMPLETE DETAILS, REFER TO CENTRIA'S WEB SITE AT www.centria.com page HORIZONTAL APPLICATION Aug. 11 CONCEPT SERIES PANELS CSH-01

Upload: truongthuan

Post on 21-Jul-2018

316 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

CSH-01 INDEX

CSH-02 STANDARD PANEL OFFERING

CSH-03 SIDE LAP DETAILS

CSH-04 WALL SECTIONS

CSH-05 WALL SECTIONS

CSH-06 WALL SECTIONS

CSH-07 BASE DETAILS

CSH-08 PARAPET DETAIL

CSH-09 VERTICAL REVEALS

CSH-10 VERTICAL REVEALS

CSH-11 END LAP DETAIL

CSH-12 HEAD OPENING DETAILS

CSH-13 HEAD OPENING DETAILS

CSH-14 JAMB OPENING DETAILS

CSH-15 SILL OPENING DETAILS

CSH-16 SILL OPENING DETAILS

CSH-17 HEAD, JAMB, SILL INTERSECTION-EXTRUSION

CSH-18 HEAD, JAMB, SILL INTERSECTION-FLASHINGS

CSH-19 END WALL DETAILS

CSH-20 SOFFIT DETAILS

CSH-21 OUTSIDE CORNER DETAILS

CSH-22 INSIDE CORNER DETAILS

CSH-23 OUTSIDE AND INSIDE CORNERS - MICROSEAM

CSH-24 4 CORNER INTERSECTION

CSH-25 PENETRATION (1 of 3)

CSH-26 PENETRATION (2 of 3)

CSH-27 PENETRATION (3 of 3)

INDEX

ELEVATION FOR DETAIL REFERENCE ONLY

23

7

3

8

20SOFFIT

15

14

12

24

O

P

E

N

I

N

G

19

25 26

23

OUTSIDE

CORNER

INSIDE

CORNER

10

18

4 5 6

4 5 6

13

16

21

11

17

9

END

WALL

27

22

NOTE:

DETAILS ARE FOR PROMOTIONAL USE

ONLY. FOR COMPLETE DETAILS, REFER

TO CENTRIA'S WEB SITE AT www.centria.com

page

HORIZONTAL APPLICATION

Aug. 11

CONCEPT SERIES PANELS

CSH-01

Page 2: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

PANEL

OFFERING

CS-660

EXTENDED FASTENING

LEG OPTION

CS-660E

CS-630E

CS-620E

CS-610E

CS-260 CS-260E

CS-220E

CS-210E

CS-200E

EXTENDED FASTENING

LEG OPTION

page

HORIZONTAL APPLICATION

Oct. 12

CONCEPT SERIES PANELS

CSH-02

CS-630 CS-620 CS-610

CS-220 CS-210 CS-200

2.4"

[61]

1.6"

[41]

7

8

"

[22]

Exterior

16"

[406]

9.6"

[244]

7

8

"

[22]

Exterior

16"

[406]

5.6"

[142]

5.6"

[142]

7

8

"

[22]

Exterior

16"

[406]

9.6"

[244]

7

8

"

[22]

Exterior

16"

[406]

7

8

"

[22]

12"

[305]

7

8

"

[22]

12"

[305]

7

8

"

[22]

12"

[305]

7

8

"

[22]

12"

[305]

2.4"

[61]

1.6"

[41]

Exterior

5.6"

[142]

Exterior

5.6"

[142]

Exterior

9.6"

[244]

Exterior

Page 3: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

CS-660CS-660E

CS-630E

CS-620E

CS-610E

Exterior

CS-260 CS-260E

CS-220E

CS-210E

CS-200E

Exterior

SIDE LAPS

page

HORIZONTAL APPLICATION

Oct. 12

CONCEPT SERIES PANELS

CSH-03

Exterior

Exterior

Exterior

Exterior

Exterior

Exterior

Exterior

Exterior

CS-620 CS-610CS-630

CS-220 CS-210 CS-200

16"[406] N

OM

IN

AL C

OV

ER

AG

E

16"[406] N

OM

IN

AL C

OV

ER

AG

E

16"[406] N

OM

IN

AL C

OV

ER

AG

E

16"[406] N

OM

IN

AL C

OV

ER

AG

E

16"[406] N

OM

IN

AL C

OV

ER

AG

E

12"[305] N

OM

IN

AL C

OV

ER

AG

E

12"[305] N

OM

IN

AL C

OV

ER

AG

E

12"[305] N

OM

IN

AL C

OV

ER

AG

E

12"[305] N

OM

IN

AL C

OV

ER

AG

E

12"[305] N

OM

IN

AL C

OV

ER

AG

E

Page 4: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

page

HORIZONTAL APPLICATION

Aug. 11

CONCEPT SERIES PANELS

CSH-04

CONCEPT SERIES

CSC-1 OR

CSC-2 CLIP

INTERIOR SHEATHING

(NBC)

INSULATION (NBC)

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

STUD (NBC)

PANELS ON PROTECTED EXTERIOR SHEATHING WITH

CAVITY INSULATION

VAPOR RETARDER LOCATION

THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT

IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS.

THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION.

VERTICAL

SUPPORTS (NBC)

PANELS WITH INSULATION

IN HORIZONTAL LINER

CONCEPT SERIES

PANEL

DRAINED &

VENTED CAVITY

AIR BARRIER

(LINER PANEL)

CONCEPT SERIES

CSC-3 CLIP

CONCEPT SERIES

PANEL

VERTICAL

3/4" [19] DEEP

16 GA. SUBGIRT

HORIZONTAL

LINER PANEL

FIELD-APPLIED

(1.65 PCF) INSULATION

IN LINER CAVITY

WEATHER-RESISTIVE

BARRIER

DRAINED &

VENTED CAVITY

FACTORY APPLIED

LINER SEALANT

(NBC) = NOT BY CENTRIA

(NBC) = NOT BY CENTRIA

Page 5: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

page

HORIZONTAL APPLICATION

Aug. 11

CONCEPT SERIES PANELS

CSH-05

CONCEPT SERIES CSC-1

OR CSC-2 CLIP AT

METALWRAP PANEL JOINTS

(3'-0" [914] O.C.)

PANELS WITH METALWRAP INSULATED

BACK-UP PANEL

CONCEPT SERIES PANEL

WEATHER-RESISTIVE BARRIER

SECTION A-A

"A" "A"

CONCEPT SERIES PANEL

CONCEPT SERIES CLIP

DRAINED &

VENTED CAVITY

INTERIOR SHEATHING

(NBC)

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

INSULATION SUITABLE

FOR MOISTURE

EXPOSURE (NBC)

STUD (NBC)

CONCEPT SERIES

CSC-3 CLIP

CONCEPT SERIES

PANEL

VERTICAL

3/4" [19] DEEP

16 GA. SUBGIRT

CON'T. HORIZONTAL

ZEE 16 [1.52] GA.

MIN. (SPACING TO

BE DETERMINED BY

CLADDING ENGINEER)

PANELS WITH INSULATION

OUTBOARD OF STUD CAVITY

DRAINED &

VENTED CAVITY

(NBC) = NOT BY CENTRIA

VAPOR RETARDER LOCATION

THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT

IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS.

THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION.

3/4" SUBFRAMING

AND AIR CAVITY

METALWRAP INSULATED

BACK-UP PANEL

METALWRAP PANEL CLIP AT EACH PANEL

SIDE JOINT (36" O.C.) VERTICALLY AND

INTO EACH FRAMING MEMBER (16" TO 24"

O.C.) HORIZONTALLY

SUBFRAMING FASTENER ANCHORED

INTO CENTER OF METALWRAP CLIP

METALWRAP

INSULATED

BACK-UP PANEL

(NBC) = NOT BY CENTRIA

Page 6: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

(NBC) = NOT BY CENTRIA

page

HORIZONTAL APPLICATION

Aug. 11

CONCEPT SERIES PANELS

CSH-06

MASONRY (NBC)

CONCEPT SERIES

CSC-3 CLIP

CONCEPT SERIES

PANEL

(*) SUBGIRTS SHALL BE

1.) 16 GA. MINIMUM.

2.) 3/4" [19] MINIMUM DEPTH.

3.) 1/4" [6] DEEPER THAN

INSULATION THICKNESS.

4.) SPACED AT 24" [610] OR

48"O.C. [1219] BASED ON

DESIGN LOADS AND

INSULATION SIZE.

PANELS WITH INSULATION

OVER MASONRY WALL

AIR BARRIER & WATER

RESISTANT COATING

OR MEMBRANE (NBC)

MASONRY FASTENER

VERTICAL SUPPORTS

(NBC)

CONCEPT SERIES PANEL

WITH EXTENDED FASTENING

LEG (NO CLIP REQUIRED)

FINISH IS REQUIRED ON BOTH

SIDES OF THE PANEL SINCE

BOTH SIDES ARE EXPOSED TO

THE WEATHER

INSULATION SUITABLE

FOR MOISTURE

EXPOSURE (NBC)

PANELS USED AS A SCREEN WALL

(NBC) = NOT BY CENTRIA

(*) CONTINUOUS

VERTICAL ZEE

SHAPED SUBGIRT

(SHIM AS REQUIRED)

VAPOR RETARDER LOCATION

THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A

REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE

THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION.

DRAINED &

VENTED CAVITY

Page 7: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

(NBC) = NOT BY CENTRIA

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

EXTERIOR SHEATHING (NBC)

CONTINUOUS STARTER FLASH

T/C

UR

B

LOCATION OF BASE FLASH WILL

VARY DUE TO CURB LOCATION

& GRADE CLEARANCE REQUIRED.

C

LR

.

VARIES

EXTEND WEATHER

RESISTIVE BARRIER

TO CURB AND

SEAL (NBC)

CLR

.

2"

[51]

SP-4222

EXTRUSION

STUDS (NBC)

SUPPORT CLIP 3" [76]

LONG @ STUD

BASE at SLAB

(EXTRUSION)

(CS-6504B)

FIELD MITER

EXTRUSION

SUBGIRT

STUDS (NBC)

CONTINUOUS STARTER FLASH

FLASHING

FLASHING

BASE at SLAB

(FLASHING)

(CS-6004)

CURING BUTYL

CSH-07

NBC

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

SELF ADHERING

FLASHING TAPE

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

SELF ADHERING

FLASHING TAPE

EXTERIOR SHEATHING (NBC)

FIELD INSTALL SHIM TO ALLOW

FOR DRAINAGE 1/8"[3]x1"[25]x2"[51]

@ 18"[457] O.C.

Page 8: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

PARAPET

(CS-6012)

STUDS (NBC)

ERECTOR NOTE:

WOOD BLOCKING,

ROOFING MEMBRANE,

& SHEATHING (NBC)

EXTEND WEATHER

RESISTIVE BARRIER

(NBC) TO BACK

SIDE OF PARAPET

2"[51]

MIN.

VARY

NON-CURING BUTYL

FLASHING

SUBGIRT

RIVET

FLASHING

SHIM FOR VENTING

12"[305] O/C

(NBC) = NOT BY CENTRIA

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

CSH-08

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)EXTERIOR

SHEATHING

(NBC)

Page 9: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

PANEL CLIP

12"[305]

MAX.

WIDE VERTICAL REVEAL

(RECESSED)

(EXTRUSION)

(CS-6505C)

SP-4169

EXTRUSION

SP-4170

EXTRUSION

STUDS (NBC)

PANEL CLIP

12"[305]

MAX.

NARROW VERTICAL REVEAL

(RECESSED)

(EXTRUSION)

(CS-6505E)

SP-4221

EXTRUSION

SP-4220

EXTRUSION

STUDS (NBC)

5/8"

[16]

3 5/8"

[92]

1"

[25]

5"

[127]

CSH-09

WEATHER-RESISTIVE

BARRIER

AND AIR BARRIER (NBC)

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE

BARRIER

AND AIR BARRIER (NBC)

EXTERIOR SHEATHING

(NBC)

(NBC) = NOT BY CENTRIA

Page 10: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

VERTICAL REVEAL

(FLASHING)

(CS-6005B)

PANEL CLIP

MIN.

1"[25]

MIN.

FLASHING

METAL AND

COMPOSITION

CLOSURE

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

STUDS (NBC)

5"

[127]

STUDS (NBC)

PANEL CLIP

VERTICAL REVEAL

(FLAT)

(EXTRUSION)

(CS-6505D)

NON-CURING BUTYL

METAL AND

COMPOSITION CLOSURES

SP-4173

EXTRUSION

SP-4169

EXTRUSION

NON-CURING BUTYL

2

1

2

"[64]

CSH-10

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

EXTERIOR

SHEATHING (NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

EXTERIOR SHEATHING

(NBC)

(NBC) = NOT BY CENTRIA

Page 11: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

2"[51] LAP

SECTION "A-A"

"A"

"A"

END LAP DETAIL

(22 [.76] AND 24 [.60] GAGES ONLY)

(NBC) = NOT BY CENTRIA

NOTE:

THIS DETAIL USED ON

WALLS WITHOUT

MICROLINE EXTRUSIONS

7/8"[22] x 6"[152] LONG

CLOSED CELL BACKER ROD

PANEL CLIP

FIELD APPLIED SEALANT

7/8"[22] x 6"[152] LONG

CLOSED CELL BACKER ROD

CONCEPT SERIES CLIP

(2 ROWS)

CURING BUTYL

END LAP DETAILISOMETRIC

(CS-6005)

STUDS (NBC)

CSH-11

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

RIVET 4" O.C.

NOTE:

STEEL CS PANELS CAN BE END

LAPPED IN A MAXIMUM

CUMULATIVE LENGTH OF

100'-0"[30480]. A REVEAL

FLASHING MUST BE ADDED TO

ACCOMMODATE THERMAL

MOVEMENT. FOR ALUMINUM CS

PANELS, THE MAXIMUM

CUMULATIVE LENGTH IS

50'-0"[15240]. SEE TB-05-06 FOR

MAXIMUM INDIVIDUAL PANEL

LENGTH IN ALUMINUM.

Page 12: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

SUBGIRTS

1

8

"[3] G

AP

WEATHER SEAL

(NBC)

PRIMARY AIR SEAL (NBC)

EXTEND WEATHER-RESISTIVE

BARRIER (NBC)

HEAD OPENING

(HIGH CELL)

( FLASHING)

(CS-6000)

HEAD OPENING

(HIGH CELL)

(EXTRUSION)

(CS-6500)

STUDS (NBC)

DOOR, WINDOW OR

LOUVER (NBC)

PRIMARY AIR SEAL

(NBC)

EXTEND WEATHER-RESISTIVE

BARRIER (NBC)

SHIM AS REQUIRED

2"

[51]

CLE

AR

O

PN

G.

SP-4141

EXTRUSION

FLASHING

CURING BUTYL

FLASHING

NON-CURING

BUTYL

SP-4143

EXTRUSION

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

DOOR, WINDOW OR

LOUVER (NBC)

STUDS (NBC)

PANEL CLIP

WEATHER SEAL

(NBC)

CSH-12

WEATHER-RESISTIVE

BARRIER AND

AIR BARRIER (NBC)

EXTERIOR SHEATHING (NBC)

SELF ADHERING

FLASHING TAPE

EXTERIOR SHEATHING

(NBC)

SELF ADHERING

FLASHING TAPE

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

(NBC) = NOT BY CENTRIA

FIELD APPLIED

BULB-WEATHER

STRIP

Page 13: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

HEAD OPENING

(ON MODULE)

(EXTRUSION)

(CS-6500B)

HEAD OPENING

(LOW CELL)

(EXTRUSION)

(CS-6500A)

PRIMARY AIR SEAL

(NBC)

SHIM AS

REQUIRED

PA

NE

L M

OD

ULE

2"

[51]

2"

[51]

STUDS (NBC)

PRIMARY AIR SEAL (NBC)

SHIM AS REQUIRED

DOOR, WINDOW OR

LOUVER (NBC)

WEATHER SEAL

(NBC)

CURING BUTYL

STARTER FLASH

SP-4143 EXTRUSION

SP-4141

EXTRUSION

CURING BUTYL

STUDS (NBC)

18[1.21] GAGE SUPPORT

CLIP, 3"[76] LONG @

STUD

18[1.21] GAGE SUPPORT

CLIP, 3"[76] LG. @ STUD

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

PANEL CLIP

SP-4141

EXTRUSION

SP-4143 EXTRUSION

DOOR, WINDOW OR

LOUVER (NBC)

WEATHER SEAL

(NBC)

SP-4142 EXTRUSION

SP-4142 EXTRUSION

CSH-13

WEATHER-RESISTIVE

BARRIER AND

AIR BARRIER (NBC)

EXTERIOR SHEATHING (NBC)

SELF ADHERING

FLASHING TAPE

EXTERIOR SHEATHING

(NBC)

SELF ADHERING

FLASHING TAPE

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

EXTEND WEATHER-RESISTIVE

BARRIER (NBC)

EXTEND WEATHER-RESISTIVE

BARRIER (NBC)

(NBC) = NOT BY CENTRIA

FIELD APPLIED

BULB-WEATHER STRIP

FIELD APPLIED

BULB-WEATHER STRIP

Page 14: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

JAMB OPENING

(FLASHING)

(CS-6003)

JAMB OPENING

(EXTRUSION)

(CS-6503)

DOOR, WINDOW OR

LOUVER (NBC)

SHIM AS REQUIRED

2"

[51]

STUDS (NBC)

PRIMARY AIR SEAL (NBC)

WEATHER SEAL (NBC)

12"[305]

MAX.

SP-4141 EXTRUSION

2

1

2

" [64]

MIN.

WEATHER SEAL (NBC)

STUDS (NBC)

PRIMARY AIR SEAL (NBC)

DOOR, WINDOW

OR LOUVER (NBC)

WEATHER SEAL

(NBC)

METAL AND

COMPOSITION

CLOSURES

CURING BUTYL

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

FLASHING

SP-4143 EXTRUSION

PANEL CLIP

CSH-14

EXTEND WEATHER

RESISTIVE BARRIER

(NBC)

EXTERIOR

SHEATHING (NBC)

WEATHER-RESISTIVE

BARRIER AND

AIR BARRIER (NBC)

SELF ADHERING

FLASHING TAPE

SELF ADHERING

FLASHING TAPE

EXTERIOR

SHEATHING (NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

EXTEND WEATHER

RESISTIVE BARRIER

(NBC)

(NBC) = NOT BY CENTRIA

Page 15: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

STUDS (NBC)

WEATHER SEAL (NBC)

WINDOW OR LOUVER

(NBC)

SHIM AS REQUIRED

2"

[51]

PRIMARY AIR SEAL

(NBC)

PANEL CLIP

FLASHING

SILL OPENING

(LOW CELL)

(FLASHING)

(CS-6007)

SUBGIRT

STUDS (NBC)

PANEL CLIP

WEATHER SEAL (NBC)

SHIMS FOR VENTING

12"[305]O/C

PRIMARY AIR SEAL

(NBC)

WINDOW OR LOUVER

(NBC)

FLASHING

SILL OPENING

(LOW CELL)

(EXTRUSION)

(CS-6506A)

FLASHING

SP-4145

EXTRUSION

SP-4141

EXTRUSION

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

CSH-15

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

EXTERIOR

SHEATHING (NBC)

EXTERIOR

SHEATHING (NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

EXTEND WEATHER

RESISTIVE BARRIER

(NBC)

(NBC) = NOT BY CENTRIA

SELF ADHERING

FLASHING TAPE

Page 16: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

WINDOW OR

LOUVER (NBC)

SILL OPENING

(HIGH CELL)

(FLASHING)

(CS-6006)

STUDS (NBC)

WEATHER SEAL (NBC)

WINDOW OR LOUVER

(NBC)

SHIM AS REQUIRED

2"

[51]

1 4

"[6]

FLASHING DESIGN MAY VARY

DUE TO PANEL MODULE LAYOUT

FLASHING

SHIMS FOR

VENTING 12"[305] O/C

WEATHER SEAL

(NBC)

SUBGIRT

PANEL CLIP

STUDS (NBC)

PRIMARY AIR SEAL

(NBC)

PRIMARY AIR SEAL

(NBC)

PANEL CLIP

FLASHING

SILL OPENING

(HIGH CELL)

(EXTRUSION)

(CS-6506)

SP-4145 EXTRUSION

FLASHING

CURING BUTYL

SP-4141 EXTRUSION

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

CSH-16

EXTEND WEATHER

RESISTIVE BARRIER

(NBC)

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

EXTEND WEATHER

RESISTIVE BARRIER

(NBC)

EXTERIOR

SHEATHING (NBC)

WEATHER-RESISTIVE

BARRIER AND

AIR BARRIER (NBC)

(NBC) = NOT BY CENTRIA

SELF ADHERING

FLASHING TAPE

Page 17: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

INTERSECTION OF

HEAD, JAMB & SILL EXTRUSION

(CS-6516)

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

CSH-17

(NBC) = NOT BY CENTRIA

Page 18: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

INTERSECTION OF

HEAD, JAMB & SILL FLASH

(CS-6016)

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

CSH-18

(NBC) = NOT BY CENTRIA

Page 19: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

STUDS (NBC)

PANEL CLIP

12"[305]

MAX.

FLASHING

SP-4141 EXTRUSION

END WALL

(EXTRUSION)

(CS-6508)

SP-4144 EXTRUSION

FIELD-APPLIED

CONTINUOUS

BEAD IN

RETAINER POCKET

METAL AND

COMPOSITION

CLOSURES

END WALL

(FLASHING)

(CS-6008)

2

1

2

" [64]

MIN.

STUDS (NBC)

FLASHING

METAL AND

COMPOSITION

CLOSURES

PANEL CLIP

1"[25]CLR.

POLYURETHANE

& BACKER ROD

NON CURING

BUTYL

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

FLASHING

CSH-19

FLASHING

EXTERIOR

SHEATHING (NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

EXTERIOR

SHEATHING (NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

SELF ADHERING

FLASHING TAPE

EXTEND

WEATHER

RESISTIVE

BARRIER (NBC)

E/PANEL

(NBC) = NOT BY CENTRIA

SELF ADHERING

FLASHING TAPE

2"

[51]

Page 20: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

STUDS (NBC)

1

8

"[3]G

AP

1

8

"[3] G

AP

2

1

2

"[64]

MIN.

OPTIONAL DETAIL

@ SOFFIT

STUDS (NBC)

2

1

2

"[64]

MIN.

SOFFIT - BACK

(FLASHING)

(CS-6014)

SOFFIT - FRONT

(FLASHING)

(CS-6013)

FLASHING

METAL AND

COMPOSITION

CLOSURES

FLASHING

SUBGIRT

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

METAL AND

COMPOSITION

CLOSURE

SUBGIRT

PANEL CLIP

PANEL CLIP

CSH-20

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

SELF ADHERING

FLASHING TAPE

EXTERIOR SHEATHING

(NBC)

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

(NBC) = NOT BY CENTRIA

Page 21: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

1'-0"[305]

MA

X.

SP-4144

EXTRUSION

OUTSIDE CORNER

(EXTRUSION)

(CS-6509)

2

1

2

"[64]

MIN.

PANEL CLIP

STUDS (NBC)

OUTSIDE CORNER

(FLASHING)

(CS-6009A)

METAL AND

COMPOSITION CLOSURE

STUDS (NBC)

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

FLASHING

METAL AND

COMPOSITION

CLOSURE

FLASHING

PANEL CLIP

CSH-21

2"

[51]

SP-4171

SP-4172

OPTIONAL

EXTRUSIONS

SP-4141

EXTRUSION

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

SELF ADHERING

FLASHING TAPE

EXTERIOR

SHEATHING (NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

(NBC) = NOT BY CENTRIA

ALTERNATE

(CS-6009)

Page 22: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

INSIDE CORNER

(FLASHING)

(CS-6010)

STUDS (NBC)

2

1 2

"[64]

MIN

.

FLASHING

INSIDE CORNER

(EXTRUSION)

(CS-6510A)

PANEL CLIP12"[305]

MA

X.

SP-4144 EXTRUSION

FLASHING

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

PANEL CLIP

METAL AND COMPOSITION

CLOSURE

SP-4141 EXTRUSION

STUDS (NBC)

CSH-22

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

SELF ADHERING

FLASHING TAPE

EXTERIOR SHEATHING

(NBC)

WEATHER-RESISTIVE

BARRIER AND AIR

BARRIER (NBC)

(NBC) = NOT BY CENTRIA

Page 23: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

SHOP ASSEMBLED

MITERED CORNER

PANEL CLIP

STUDS (NBC)

2"[51]

LAP

INSIDE CORNER

MICROSEAM

(CS-6018)

2"[51]

LA

P

24"[610] (S

TA

ND

AR

D)

15"[381] M

IN

IM

UM

, 42"[1067] M

AX

IM

UM

PANEL CLIP

SHOP ASSEMBLED

MITERED CORNER

TYPICAL OVERLAP DETAILS FOR

22[0.76] OR 24[0.60] GAGE PANELS

ONLY.

2"[51]

LAP

OUTSIDE CORNER

MICROSEAM

(CS-6017)

page

HORIZONTAL APPLICATION

Aug. 11

CONCEPT SERIES PANELS

24"[610] (STANDARD)

15"[381] MINIMUM, 42"[1067] MAXIMUM

STUDS (NBC)

CSH-23

7

4

°

M

i

n

.

1

3

5

°

M

a

x

.

7

4

°

M

i

n

.

1

3

5

°

M

a

x

.

EXTERIOR SHEATHING (NBC)

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

EXTERIOR SHEATHING (NBC)

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

(NBC) = NOT BY CENTRIA

Page 24: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

A B D

C

F

E G

H J

L

I K M

DIAGRAM "A"

(BUILDING ELEVATION)

TYPICAL HORIZONTAL PANEL ERECTION PROCEDURE

(REFER TO DIAGRAM "A" BELOW FOR ERECTION SEQUENCE)

NOTE:

AFTER LAPPING PANEL~B OVER PANEL~A , THE A & B PANEL

CLIP MUST BE INSTALLED PRIOR TO PANEL~C BEING INSTALLED.

THIS PROCEDURE SHALL BE TYPICAL FOR ALL SUBSEQUENT

PANELS.

FOUR CORNER

INTERSECTION

(CS-6019)

CSH-24

(NBC) = NOT BY CENTRIA

Page 25: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

page

HORIZONTAL APPLICATION

Aug. 11

CONCEPT SERIES PANELS

PENETRATION DETAIL

(CS-6015)

(NBC) = NOT BY CENTRIA

CSH-25

REF. PAGE FOR SECT. A-A

NOTE:-

CSH-26

REF. PAGE FOR SECT. B-BCSH-27

Page 26: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

1

8

"[3"]G

AP

STUDS (NBC)

FLASHING

SECTION A-A

(CS-6015A)

FLAT FLASHING

FLASHING

FLASHING

SUBGIRT

FLASHING

PENETRATION DETAIL

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

SUBGIRT

FLASHING

POLYURETHANE

(TYPICAL ALL AROUND)

CSH-26

EXTERIOR SHEATHING (NBC)

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

SELF ADHERING

FLASHING TAPE

SELF ADHERING

FLASHING TAPE

(NBC) = NOT BY CENTRIA

Page 27: CONCEPT SERIES PANELS - doc.spdirect.netdoc.spdirect.net/files/ALL CONCEPT SERIES HORIZONTAL PROMOTI… · concept series panels csh-02 cs-630 cs-620 cs-610 ... vapor retarder location

SECTION B-B

(CS-6015B)

PENETRATION DETAIL

page

HORIZONTAL APPLICATION

June 15

CONCEPT SERIES PANELS

CSH-27

STUDS (NBC)

SUBGIRT

POLYURETHANE SEALANT

ALL AROUND

FLAT FLASHING

FLASHING

SELF ADHERING

FLASHING TAPE

EXTERIOR SHEATHING (NBC)

WEATHER-RESISTIVE BARRIER

AND AIR BARRIER (NBC)

METAL AND

COMPOSITION

CLOSURES

(NBC) = NOT BY CENTRIA