Conceptpower Modular 80 and 100kVA. THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT IT. Unique Power Protection Concept (PPC). 6 Key-Features at a Glance. Modularity Redundancy Scalability Environmentally Friendly Serviceability Manageability. Static Bypass. Load. Rect. Boost. - PowerPoint PPT Presentation

TRANSCRIPT

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 1

Conceptpower Modular80 and 100kVA

THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT IT

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 2

Unique Power Protection Concept (PPC)

6 Key-Features at a Glance

Modularity

Redundancy

Scalability

Environmentally Friendly

Serviceability

Manageability

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 3

ConceptpowerTM Modular

First and unique hot swappable 3phase double conversion (VFI) UPS modular design

2 possible power ranges:

80 and 100kVA

Modularity

Welcome to the future of power protection

Batt. Batt.Charge

r

Static Bypass

Rect. Boost.

Inverter

Load

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 4

ConceptpowerTM Module

Front view 80-100kVA

Passive module includes:• Input filter• Output filter• Booster coils• Static By-pass

Active module includes:• Rectifier & Booster• Battery charger• Inverter• µProcessor control board

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 5

ConceptpowerTM Module

Front view 80-100kVADry contacts

NC/NO, D25P/Fconnection

EPO, Gen-on, Batt.temp.connector

LCD Display Panelconnector

Module Interfaceconnector

Smart port RS232

By-pass line fuses

ComBus Module to Module

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 6

ConceptpowerTM Module

Weight of the passive module80-100 kVA: 55-60 Kg

Size of the UPS module:667x412x834mm (WxHxD)

Weight of the active module80-100 kVA: 55-60 Kg

Size of the UPS module:667x412x834mm (WxHxD)

Rear view 80-100kVA

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 7

ConceptpowerTM Module

Inside view 80-100kVA

InverterBooster

Batt. Charger

DC Cap.

µ Control boardBy-pass

Input LCFIlter

OutputLC Filter

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 8

ConceptpowerTM Modular

Welcome to the future of power protection

Power modules: 80-100 kVA

Upgrade frame 300 kVA

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 9

ConceptpowerTM Modular

UPGRADE FRAMEPower modules: 80-100kVA

Limited up to 10 modules in parallel (> 10 modules on request)

Distribution section for the max. capacity (300kVA)

Space saving, 300kVA in 1.22 sqm.

No single point of failureUPS – module 2

Distribution300kVA

UPS – module 3

UPS – module 1

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 10

ConceptpowerTM Modular

UPGRADE FRAME DISTRIBUTION 300KVA

Modules output disconnects

Centralized MaintenanceBy-pass

Centralized SNMP Slot (Multidrop).

DPA extension bus

RS232, PFC, EPO

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 11

ConceptpowerTM Modular - Scalability

Optimized capital investment by extending your power protection capacity at a pace that fits your business on demand

Scalable performance of the power capacity and runtime by simply adding independent UPS or battery increments

Upgrade Frame (Vertical Scalability)(floor-saving-frame)

UPS – module 2

Distribution300kVA

UPS – module 3

UPS – module 1

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 12

No additional hardware for harmonic reduction is required

ConceptpowerTM Modular Environmentally Friendly

1997/06/03 10:54:36 5ms/div

(5ms/div) NORM:200kS/s

Input Voltage

Input Current

Sinewave input current (THD=7-9%)

Input PF=0.98 in a standard version

This means:

Smaller cables size and lower losses

Smaller fuses or Circuit Breakers

(no malfunction and false tripping)

No separate phase compensation required

No extra heating of transformer and generators oversized

6-pulse rectifier

12-pulse rectifier

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 13

The total annual operating costs for a Newave UPS can be >40% less compared to those for a previous generation

ConceptpowerTM Modular Environmentally Friendly

Highest double-conversion efficiency ESIS (Energy Saving Inverter Switching) up to 95% in on- line, double conversion mode

Load dependent audible noise

Wide input frequency windows (35-70Hz)

Low weight (3x100kVA: 700kg)

Compact size (3x100kVA: 1.22 sqm)

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 14

ConceptpowerTM Modular Environmentally Friendly

Product positioningCase 1: configuration required 2x200kVA redundant

Legacy 2x200kVA UPS configuration

6 Pulse UPS (2x1.24 sqm)

12 Pulse rectifier (2x0.55 sqm)

Harmonic Filter& PFC (2x0.55 sqm)

Total footprint required: 4.68 sqm

Total weight: >3500Kg

UPS –2UPS –1 12 Pulse 12 PulseHarmonicFilter &PFC

HarmonicFilter &PFCUPS –

module 2

Distribution

300kVA

UPS – module

3

UPS – module

1

Modular 3x100kVA

Total footprint

required: 1.22 sqm

Total weight: 700Kg

Distribution200kV

A

UPS –1

Distribution200kV

A

UPS –2

MAXI 2x200kVA

Total footprint required: 1.8 sqm

Total weight: 1280Kg

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 15

ConceptpowerTM Modular Environmentally Friendly

Product positioningCase 2: configuration required 2x500kVA redundant

UPS – module 2

Distributio

n300kV

A

UPS – module 3

UPS – module 1

Modular 6x100kVA

Total footprint

required: 2.44 sqm

Total weight: 1400Kg

UPS – module 5

Distributio

n300kV

A

UPS – module 6

UPS – module 4

Distribution

250kVA

UPS –1

MAXI 3x250kVA

Total footprint required: 2.7 sqm

Total weight: 1980Kg

Distribution

250kVA

UPS –2

Distribution

250kVA

UPS –3

Legacy 2x500kVA UPS configuration

12 Pulse UPS (2x2.1 sqm)

Harmonic Filter& PFC (2x0.88 sqm)

Total footprint required: 5.96 sqm

Total weight: >6200Kg

UPS –1& 12 Pulse

HarmonicFilter &PFC

UPS –2& 12 Pulse

HarmonicFilter &PFC

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 16

Battery cost saving

Flexible Battery Management (FBM)

Variable DC-voltage enabling the use of battery blocks (40-50 blocks of 12VDC)

Wide input voltage windows (-23%/+15% @100% load) (-30%/+15% @<80% load) (-40%/+15% @<60% load)

Less need for battery operation

Automatic battery test with algorithm CPU controlled Early warning in case of battery fault

Temperature compensation Increases battery lifetime

Ripple free through battery charger Longer battery life time

020406080

100120

0 2 4 6 8 10

Time

Rip

ple

s

LegacyUPS

0

0,2

0,4

0,6

0,8

1

0 2 4 6 8 10

Time

Rip

ple

s ConceptpowerUPS

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 17

Modular and hot-swappable design means minimizing service and maintenance cost and

Reduction of MTTR, maximize

your power protection

availability

Front access only

No needs for skilled personnel

on site

No need of spares, just modules

ConceptpowerTM Modular Serviceability

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 18

Redundant Power Management Display advances the Power Protection Manageability

Common data execution functions for parallel systems on redundant parallel PMD’s.

The complete parallel system may be managed by any one of the parallel PMD’s.

PMD consists of mimic diagram for system status, push buttons for single module and parallel system control and LCD for monitoring, event logs and diagnosis.

ConceptpowerTM Modular Manageability

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 19

ALARM

LINE 2

LINE 1

BATTERY

BY PASS

INV RESET ENTER

LCD Display ON / OFF

ON / OFF

ConceptpowerTM Module Display

Most important information available at first glance

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 20

Remote Signalling Panel (RSP)For Status and Alarm Remote Indications

Wavemon (CD)For Automatic Server shutdownand Monitoring. Cross Platform shutdown available

SNMP-card or Box for connection of UPS in Network Management systems

ConceptpowerTM Modular Remote Control and Shutdown

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 21

1. Optimize capital investment and available space Pay-as-you-grow solution lowers your capital costs and increases utilization rates, while innovative rack-based technology frees up space previously needed for infrastructure support.

2. Adapt to ever-changing power requirements No need to abandon previous investment when power density needs increase or if physically moving your data centre. Adapt to changing wattage requirements in your racks with single- or multi-branch rack-mount power distribution units.

3. Accelerate speed of deployment Electrical and physical modularity allows for rapid installation with minimal engineering.

4. Lower the cost of service contracts Simplicity of system design and intelligent modular parts lessen the dependency on expensive service contracts.

5. Increase availability Specifically engineered to deliver higher availability through proactively designed, building block architecture and reduced MTTR

10 reasons for buying ConceptpowerTM Modular

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 22

10 reasons for buying ConceptpowerTM Modular

6. Decrease mean-time-to-recovery (MTTR) Compartmentalize potential failures with system components consisting of intelligent, maintainable modules for quick fault recovery.

7. Plan for a power density that is increasing and unpredictable Eliminate hot spots in your data centre caused by higher power densities by targeting availability where you need it most.

8. Minimize points of failure between the UPS and the critical load Move redundancy closer to the load and prevent the majority of failures that cause critical load downtime.

9. Minimize human error Simplicity of design and intelligent modules increase system availability by mitigating human error: the number one cause of critical load downtime.

10. Decrease the operating costs With efficiency up to 95% (double conversion mode), the operating costs for a Conceptpower modular UPS can be >40% less compared to those for a previous generation

Newave SA, Switzerland – [email protected] - www.newaveups.com28/02/2006 23

Swiss Quality

• INNOVATIONINNOVATION

• SUPPORTSUPPORT

• QUALITYQUALITY

Power Protection Leader Through Innovation

TO PROTECT YOUR MISSION CRITICAL APPLICATIONS