constructionnot for

9
G:\20203-2083\1-CIVIL ENGINEERING\3-PLAN SHEETS\2083 COVER.DWG PLOTTED BY MICKY DOBSON ON: 8/18/2021 10:43 AM LAST UPDATED BY MDOBSON ON: 8/16/2021 1:44 PM G:\20203-2083\1-CIVIL ENGINEERING\3-PLAN SHEETS\2083 COVER.DWG PLOTTED BY MICKY DOBSON ON: 8/18/2021 10:43 AM LAST UPDATED BY MDOBSON ON: 8/16/2021 1:44 PM C0.0 COVER SHEET METRO CASE #: 2021SP-045-001 EXCAVATION PERMIT #: ---------- SWGR PERMIT #: ---------- SEWER PROJECT #: ---------- BUILDING PERMIT #: ---------- PARCEL IDs: ---------- GreshamSmith.com Drawn By: Checked By: Approved By: DATE: PROJECT: LINE IS 3 INCHES WHEN PRINTED FULL SIZE FULL SHEET SIZE = 34"X44" 222 2nd Avenue South, Nashville, TN 37201 615.770.8100 SEAL PROJECT CLIENT CONSULTANT NOT FOR CONSTRUCTION 12/18/2020 1:48:13 PM BIM 360://44011.00 Circle South R21/44011.01_CS_Office_500K_R21.rvt 20203-2083 08/09/21 Author Checker Approver 2416 West End Nashville, Davidson County, TN PRELIMINARY SP Revision No. Date Description METRO CASE# 2021-SP-045-001 1 6.29.21 SP Resubmittal 2 7.08.21 SP Resubmittal 3 8.05.21 SP Resubmittal SITE 2416 WEST END AVENUE PRELIMINARY SP LOCATION: 821, 823, 825, & 827 19TH AVE S, NASHVILLE, TN COVER SHEET C0.0 INDEX OF SHEETS DEVELOPER FIONA HAULTER GBT REALTY CORPORATION 9010 OVERLOOK BLVD BRENTWOOD, TN 37027 (615) 370-0670 [email protected] CIVIL BRAD SLAYDEN, PE RAGAN SMITH & ASSOCIATES, INC. 315 WOODLAND STREET NASHVILLE, TN 37206 (615) 244-8591 [email protected] ARCHITECTURE GRESHAM SMITH & PARTNERS 222 2ND AVE, SUITE 1400 NASHVILLE, TN 37201 (615) 770-8100 SURVEY YOUNG-HOBBS AND ASSOCIATES 1202 CROSSLAND AVE. CLARKSVILLE, TN 37040 931-645-2524 CONTACTS CIVIL PLANS SHEET DESCRIPTION PURPOSE NOTE THE PURPOSE OF THIS SP IS TO REZONE TO PERMIT A MAXIMUM OF 375 RESIDENTIAL UNITS AND A MAXIMUM OF 70,000 SF OF OTHER USES PERMITTED WITHIN THE MUG-A. SHORT TERM RENTAL PROPERTY OWNER OCCUPIED AND NOT OWNER OCCUPIED SHALL BE PERMITTED. EXISTING PROPERTY INFORMATION COUNCIL DISTRICT NUMBER: 21 DISTRICT COUNCIL MEMBER: BRANDON TAYLOR PROPERTY OWNER(1): GTOM WEST END, LLC 9010 OVERLOOK BLVD BRENTWOOD, TN 37027 PROPERTY OWNER(2): TIDMAN, J. HASKELL JR. ET AL 1155 CRATER HILL DRIVE NASHVILLE, TN 37215 PROPERTY OWNER(3): BAURLE, ERIC J & EADS, MATTHEW B & ELLIS, TRUITT ETAL 4421 SHEPPARD PL NASHVILLE, TN 37205 PARCELS & ACREAGE: (PARCELS 016, 131, 132, 133) TOTAL AREA: 37,897 SF [0.87 AC] (CS = 0.49 AC; MUG-A = 0.38 AC) EX. BUILDING SF: 22,197 SF TAX MAP: 104-03, 92-15 METRO GIS ID: 10403001600, 09215013100, 09215013200, 09215013300 STREET ADDRESS: 2416 WEST END AVE, 2413 ELLISTON PL, 2412 WEST END AVE, 2410 WEST END AVE NASHVILLE, TN 37203 ZONING: OV-UZO, CS (COMMERCIAL SERVICE) MUG-A (MIXED USE GENERAL -ALTERNATIVE) EXISTING LAND USE: PARCEL 016: RESTAURANT/VACANT PARCEL 131: VACANT PARCEL 132: RESTAURANT PARCEL 133: RETAIL COMMUNITY PLAN: GREEN HILLS-MIDTOWN COMMUNITY PLAN POLICY AREA: 10-MT-T5-MU-01 (T5 CENTER MIXED USE NEIGHBORHOOD AREA 1) BUILDING SETBACKS FRONT 0'-15' Measured from back of sidewalk SIDE 0' Measured from back of sidewalk REAR 20' MAX HEIGHT: 20 STORIES (AND ABOVE) BUFFER YARDS: N/A MAX FAR: CS: 0.6; MUG-A: 3.0 MAX ISR: CS: 0.9; MUG-A: 0.9 EXISTING SIDEWALKS: ELLISTON PLACE: SIDEWALK WIDTH VARIES 8'-10', NO GRASS STRIP WEST END AVE: SIDEWALK WIDTH VARIES 8'-10', NO GRASS STRIP PROPOSED DEVELOPMENT SUMMARY APPLICATION DATE: 06/09/2021 SP NUMBER: 2021SP-045-001 ZONING: SP LOTS: LOT 1; TOTAL LOT AREA = 37,897 SF (0.87 AC) PROPOSED LAND USE: ALL USES ALLOWED UNDER MUG-A ZONING PROPOSED BUILDING ABOVE GRADE GROSS AREA (SF): 556,000 SF GROSS BUILDING AREA MAX SF OF NON-RESIDENTIAL: NON-RESIDENTIAL MAX SF IS LIMITED TO 70,000 SF. ABOVE GRADE NON-RESIDENTIAL USES SHALL BE LOCATED ON LEVELS 1 AND 2. THE TOTAL SQUARE FOOTAGE SHALL INCLUDE ANY LEASABLE SPACES ABOVE OR BELOW GRADE ASSOCIATED WITH THE NON-RESIDENTIAL USES MAX RESIDENTIAL UNITS: MAXIMUM RESIDENTIAL UNITS = 375 UNITS (PROPOSED DEVELOPMENT SUMMARY CONTINUED) STRP (SHORT TERM RENTAL PROPERTY) NOTE: NON-OWNER OCCUPIED AND OWNER OCCUPIED STRPs SHALL BE PERMITTED BULK REGULATIONS: MIN BUILDING SETBACKS FRONT 0' Measured from back of sidewalk SIDE 0' Measured from back of sidewalk REAR 0' MAX BUILDING HEIGHT: THE BUILDING HEIGHT AT THE TALLEST POINT IS 374'-0" FROM THE LOBBY, NOT INCLUDING THE PARAPET AS SHOWN ON THE UPDATED ELEVATION. WHEN MEASURING THE HIGHEST POINT OF THE BUILDING FROM THE LOWEST ADJACENT STREET GRADE (THE NORTHEAST CORNER OF THE PROPERTY), THE TALLEST POINT OF THE BUILDING IS 380'-0" ABOVE STREET GRADE. MAX BUILDING STORIES: 27 STORIES ABOVE GRADE (MECHANICAL EQUIPMENT PENTHOUSES ARE NOT INCLUDED) BUFFER YARDS: N/A MAX FAR: 15.0 (THE MAX FAR EXCLUDES ALL BELOW GRADE AREAS). (16.0 MAX FAR IF INCLUDING ALL LEASABLE SPACE EXCLUDING GARAGE) MAX ISR: 1.0 PROPOSED SIDEWALKS (PER MCSP): ELLISTON PLACE (T5-M-AB3): 4' FURNISHING ZONE (4'X6' TREE WELLS), 10' SIDEWALK WEST END AVE (T5-M-AB6-IM): 4' FURNISHING ZONE (4'X6' TREE WELLS), 10' SIDEWALK, 4' FRONTAGE ZONE PARKING SUMMARY REQ. PARKING STATEMENT: BASED ON METRO REQUIREMENTS FOR USES. [17.20.030 & 17.20.040) PARKING ADJUSTMENT PER 17.20.040: 17.20.040.G - WITHIN THE URBAN ZONING OVERLAY, NO PARKING SHALL BE REQUIRED FOR USES LOCATED ON MULTIMODAL CORRIDORS, AS DESIGNATED IN THE MAJOR AND COLLECTOR STREET PLAN (MCSP). THE MCSP DESIGNATES WEST END AVENUE AS A MULTIMODAL CORRIDOR. PROPOSED PARKING: 4.5 STORIES BELOW GRADE REQ. ADA PARKING SPACES: PER CODE PROP. ADA PARKING SPACES: PER CODE LOADING SPACE REQ.: PER 17.20.130 LOADING SPACES PROPOSED: SEE PLANS REQ. BICYCLE STATEMENT: BASED ON METRO REQUIREMENTS [BL2014-714] (17.20.135) PROPOSED BICYCLE SPACES: BASED ON METRO REQUIREMENTS [BL2014-714] (17.20.135) THE FINAL SP WILL ALLOCATE BIKE PARKING PER THE CODE WHICH IS DETERMINED BY THE FINAL RESIDENTIAL UNIT COUNT AND RETAIL SF. DEVELOPMENT STANDARDS 1. BUILDINGS SHALL AVOID CONTINUOUS UNINTERRUPTED BLANK FACADES. SEE ARCHITECTURAL ELEVATIONS AND RENDERINGS FOR ADDITIONAL DETAIL. 2. SIDEWALKS SHALL BE CONSTRUCTED TO THE STANDARD OF THE MAJOR AND COLLECTOR STREET PLAN OR, IF ON A LOCAL STREET, TO LOCAL STREET STANDARDS. THE BUILD-TO ZONE FOR ALTERNATIVE ZONING DISTRICTS SHALL BE MEASURED SHAll BE MEASURED FROM THE STANDARD RIGHT-OF-WAY LINE AS ESTABLISHED BY THE TABLE ENTITLED “STANDARD STREET RIGHT-OF-WAY WIDTHS” IN THE MAJOR AND COLLECTOR STREET PLAN. 3. THE POTENTIAL PEDESTRIAN ENTRANCES DISPLAYED ON THE SITE LAYOUT PLAN ARE SUBJECT TO CHANGE IN THE FINAL SP AND TENANT IMPROVEMENT PLANS SUBMITTAL TO CODES. GENERAL NOTES 1. ANY STANDARD NOT SPECIFICALLY ADDRESSED HEREIN SHALL COMPLY WITH THE MUG-A BASE ZONING REQUIREMENTS AS OF THE APPLICATION DATE OF THIS PRELIMINARY SP. 2. LOT IS TO BE SERVED WITH PUBLIC WATER AND SANITARY SEWER. 3. SITE, OPEN SPACES, WATER QUALITY & DETENTION FACILITIES TO BE MAINTAINED BY PROPERTY OWNER OR PROPERTY OWNER'S ASSOCIATION. 4. REFUSE COLLECTION, RECYCLING AND MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW BY THE COMBINATION OF FENCES, WALLS OR LANDSCAPING (SECTION 17.24.060 OF THE METRO ZONING CODE). 5. THE DEVELOPER'S FINAL CONSTRUCTION DRAWINGS SHALL COMPLY WITH THE DESIGN REGULATIONS ESTABLISHED BY THE DEPARTMENT OF PUBLIC WORKS. FINAL DESIGN MAY VARY BASED ON FIELD CONDITIONS. 6. ALL WORK IN THE PUBLIC RIGHT-OF-WAY REQUIRES A PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS. 7. STORM WATER WILL BE ROUTED THROUGH A STORMWATER QUALITY MANAGEMENT SYSTEM, SIZED PER THE DESIGN CRITERIA SET FORTH BY THE METRO STORMWATER MANAGEMENT MANUAL. 8. APPROVAL OF ANY SPECIFIC PLAN DOES NOT EXEMPT ANY PARCEL SHOWN ON THE PLAN OR ANY DEVELOPMENT WITHIN THE SP FROM COMPLIANCE WITH ALL PROVISIONS OF THE METRO ZONING CODE WITH RESPECT TO FLOODPLAIN, STEEP SLOPES, UNSTABLE SOILS, SINKHOLES, ROCK OUTCROPPINGS, STREAMS, SPRINGS AND CRITICAL LOTS. 9. IF REQUIRED, A SUBDIVISION PLAT WILL BE SUBMITTED WITH THE FINAL SP DOCUMENTS. 10. THE FINAL SITE PLAN/ BUILDING PERMIT SITE PLAN SHALL DEPICT THE REQUIRED PUBLIC SIDEWALKS, ANY REQUIRED GRASS STRIP OR FRONTAGE ZONE AND THE LOCATION OF ALL EXISTING AND PROPOSED VERTICAL OBSTRUCTIONS WITHIN THE REQUIRED SIDEWALK AND GRASS STRIP OR FRONTAGE ZONE. PRIOR TO THE ISSUANCE OF USE AND OCCUPANCY PERMITS, IT SHALL BE CONSIDERED FOR EXISTING VERTICAL OBSTRUCTIONS TO BE RELOCATED OUTSIDE OF THE REQUIRED SIDEWALK. VERTICAL OBSTRUCTIONS ARE ONLY PERMITTED WITHIN THE REQUIRED GRASS STRIP OR FRONTAGE ZONE. 11. BILLBOARDS SHALL NOT BE PERMITTED. 12. SIDEWALK CONSTRUCTION TO COMPLY WITH MCSP. SIDEWALKS ARE TO BE LOCATED WITHIN DEDICATED R.O.W. 13. FEDERAL COMPLIANCE: ALL DEVELOPMENT WITHIN THE BOUNDARIES OF THIS PLAN SHALL MEET THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT AND THE FAIR HOUSING ACT. ADA: HTTP://WWW.ADA.ORG US JUSTICE DEPT: HTTP://WWW.JUSTICE.GOV/CRT/HOUSE/FAIRHOUSING/ABOUT_ FAIRHOUSINGACT.HTML 14. 78-840 NOTE: ANY EXCAVATION, FILL OR DISTURBANCE OF THE EXISTING GROUND ELEVATION MUST BE DONE IN ACCORDANCE WITH STORM WATER MANAGEMENT ORDINANCE NO. 78/840 AND APPROVED BY THE METROPOLITAN DEPT. OF WATER SERVICES. 15. ACCESS NOTE: METRO WATER SERVICES SHALL BE PROVIDED SUFFICIENT & UNENCUMBERED ACCESS IN ORDER TO MAINTAIN AND REPAIR UTILITIES IN THIS SITE. 16. FIRE DEPT. NOTE: FIRE-FLOW SHALL MEET THE REQUIREMENTS OF THE INTERNATIONAL FIRE CODE - 2012 EDITION; AS AMENDED. 17. PRELIMINARY PLAN NOTE: MINOR MODIFICATIONS TO THIS PRELIMINARY SP PLAN MAY BE APPROVED BY THE PLANNING COMMISSION OR ITS DESIGNEE BASED UPON FINAL ARCHITECTURAL, ENGINEERING OR SITE DESIGN AND ACTUAL SITE CONDITIONS. ALL MODIFICATIONS SHALL BE CONSISTENT WITH THE PRINCIPLES AND FURTHER THE OBJECTIVES OF THE APPROVED PLAN. MODIFICATIONS SHALL NOT BE PERMITTED, EXCEPT THROUGH AN ORDINANCE APPROVED BY METRO COUNCIL THAT INCREASE THE PERMITTED DENSITY OR FLOOR AREA, ADD USES NOT OTHERWISE PERMITTED, ELIMINATE SPECIFIC CONDITIONS OR REQUIREMENTS CONTAINED IN THE PLAN AS ADOPTED THROUGH THIS ENACTING ORDINANCE, OR ADD VEHICULAR ACCESS POINTS NOT CURRENTLY PRESENT OR APPROVED. 18. STORMWATER PRELIMINARY PLAN NOTE: DRAWING IS FOR ILLUSTRATION PURPOSES TO INDICATE THE BASIC PREMISE OF THE DEVELOPMENT, AS IT PERTAINS TO STORMWATER APPROVAL / COMMENTS ONLY. THE FINAL LOT COUNT AND DETAILS OF THE PLAN SHALL BE GOVERNED BY THE APPROPRIATE STORMWATER REGULATIONS AT THE TIME OF FINAL APPLICATION. 19. FEMA NOTE: NO PORTION OF THIS PARCEL DESCRIBED HEREON LIES WITHIN FLOOD HAZARD AREA IN ACCORDANCE WITH "INSURANCE RATE MAP PANEL NO. 47037C0243H", DATED: APRIL 5, 2017 (PANEL NOT PRINTED). 20. SURVEY NOTE: TOPOGRAPHIC INFORMATION AND BOUNDARY INFORMATION TAKEN FROM SURVEYS PREPARED BY YOUNG - HOBBS AND ASSOCIATES DECEMBER 20, 2020. 21. BUFFER NOTE: THE BUFFER ALONG WATERWAYS WILL BE AN AREA WHERE THE SURFACE IS LEFT IN A NATURAL STATE IS NOT DISTURBED BY CONSTRUCTION ACTIVITY. THIS IS IN ACCORDANCE WITH THE STORMWATER MANAGEMENT MANUAL VOLUME 1 REGULATIONS. 22. C/D NOTE: SIZE DRIVEWAY CULVERTS PER THE DESIGN CRITERIA SET FORTH BY THE METRO STORMWATER MANAGEMENT MANUAL (MINIMUM DRIVEWAY CULVERT IN METRO ROW IS 15" CMP). 23. SITE SOILS: THE HYDROLOGIC SOIL GROUP CLASSIFICATION FOR THIS 0.87 LAND AREA IS McB (MAURY-URBAN LAND COMPLEX, 2 TO 7 PERCENT SLOPES) WHICH IS GROUP B RATING 24. BALCONIES ARE TO BE ALLOWED. GENERAL PLAN CONSISTENCY LAND USE POLICY THIS SITE IS LOCATED IN THE T5 MU DISTRICT OF THE GREEN HILLS / MIDTOWN COMMUNITY PLAN. T5 MU IS INTENDED TO MAINTAIN, ENHANCE, AND CREATE HIGH-INTENSITY URBAN MIXED USE NEIGHBORHOODS WITH A DEVELOPMENT PATTERN THAT CONTAINS A DIVERSE MIX OF RESIDENTIAL AND NON-RESIDENTIAL LAND USES. T5 MU AREAS ARE INTENDED TO BE AMONG THE MOST INTENSE AREAS IN DAVIDSON COUNTY. T5 MU AREAS INCLUDE SOME OF NASHVILLE'S MAJOR EMPLOYMENT CENTERS SUCH AS MIDTOWN THAT REPRESENT SEVERAL SECTORS OF THE ECONOMY INCLUDING HEALTH CARE, FINANCE, RETAIL, THE MUSIC INDUSTRY, AND LODGING. T5 MU AREAS ALSO INCLUDE LOCATIONS THAT ARE PLANNED TO EVOLVE TO A SIMILAR FORM AND FUNCTION. COMMUNITY PLAN COMPLIANCE THE PROPOSED DEVELOPMENT WILL PROVIDE COMMERCIAL AND RESIDENTIAL LAND USES TO THE NEARBY LAND USES. ACCESS WITHIN THE OVERALL DEVELOPMENT IS DESIGNED TO BE PEDESTRIAN FRIENDLY WITH CROSSWALKS AND SIDEWALKS TO PROVIDE SAFE INTERACTION BETWEEN PEDESTRIAN AND VEHICULAR TRAFFIC. THE BUILDING IS ORIENTED TOWARDS THE STREET WITH BUILDING FORMS THAT COMPLIMENT THE ADJACENT NEIGHBORHOODS. LIGHTING WILL BE PROVIDED THROUGHOUT THE DEVELOPMENT TO PROVIDE SAFETY AT BUILDINGS AND VEHICULAR AND PEDESTRIAN AREAS WHILE ENHANCING THE CHARACTER OF THE CENTER. SITE DATA EXISTING CONDITIONS SITE LAYOUT PLAN TRUCK MOVEMENT PLAN C0.2 C1.1 C1.2 BUILDING ELEVATION - NORTH A01 ARCHITECTURAL PLANS BUILDING ELEVATION - SOUTH A02 BUILDING ELEVATION - WEST AND EAST A03 CONCEPTUAL RENDERINGS A04 ROOF PLAN A228

Upload: others

Post on 16-Oct-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CONSTRUCTIONNOT FOR

G:\2

02

03

-2

08

3\1

-C

IV

IL E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\2

08

3 C

OV

ER

.D

WG

PLO

TT

ED

B

Y M

IC

KY

D

OB

SO

N O

N: 8

/1

8/2

02

1 1

0:4

3 A

M

LA

ST

U

PD

AT

ED

B

Y M

DO

BS

ON

O

N: 8

/1

6/2

021

1:4

4 P

M

G:\2

02

03

-2

08

3\1

-C

IV

IL E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\2

08

3 C

OV

ER

.D

WG

PLO

TT

ED

B

Y M

IC

KY

D

OB

SO

N O

N: 8

/1

8/2

02

1 1

0:4

3 A

M

LA

ST

U

PD

AT

ED

B

Y M

DO

BS

ON

O

N: 8

/1

6/2

021

1:4

4 P

M

C0.0

COVER SHEET

METRO CASE #: 2021SP-045-001

EXCAVATION PERMIT #: ----------

SWGR PERMIT #: ----------

SEWER PROJECT #: ----------

BUILDING PERMIT #: ----------

PARCEL IDs: ----------

GreshamSmith.com

Draw

n B

y:

Checked B

y:

Approved B

y:

DATE:

PROJECT:

LINE IS 3 INCHES WHEN PRINTED FULL SIZE

FULL SHEET SIZE = 34"X44"

222 2nd Avenue South,

Nashville, TN 37201

615.770.8100

SEAL

PROJECT

CLIENT

CONSULTANT

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

12/18/2020 1:48:13 PM

BIM

360://44011.00 Circle South R21/44011.01_CS_O

ffice_500K_R21.rvt

20203-2083

08/09/21

Author

Checker

Approver

2416 W

est End

Nashville, D

avidson County, TN

PRELIM

IN

ARY SP

Revision

No. Date Description

METRO

CASE#

2021-SP-045-001

16.29.21 SP Resubmittal

27.08.21 SP Resubmittal

38.05.21 SP Resubmittal

SITE

2416 WEST END AVENUE

PRELIMINARY SP

LOCATION: 821, 823, 825, & 827 19TH AVE S, NASHVILLE, TN

COVER SHEETC0.0

INDEX OF SHEETS

DEVELOPER

FIONA HAULTER

GBT REALTY CORPORATION

9010 OVERLOOK BLVD

BRENTWOOD, TN 37027

(615) 370-0670

[email protected]

CIVIL

BRAD SLAYDEN, PE

RAGAN SMITH & ASSOCIATES, INC.

315 WOODLAND STREET

NASHVILLE, TN 37206

(615) 244-8591

[email protected]

ARCHITECTURE

GRESHAM SMITH & PARTNERS

222 2ND AVE, SUITE 1400

NASHVILLE, TN 37201

(615) 770-8100

SURVEY

YOUNG-HOBBS AND ASSOCIATES

1202 CROSSLAND AVE.

CLARKSVILLE, TN 37040

931-645-2524

CONTACTS

CIVIL PLANS

SHEET DESCRIPTION

PURPOSE NOTE

THE PURPOSE OF THIS SP IS TO REZONE TO PERMIT A MAXIMUM OF 375 RESIDENTIAL

UNITS AND A MAXIMUM OF 70,000 SF OF OTHER USES PERMITTED WITHIN THE MUG-A.

SHORT TERM RENTAL PROPERTY OWNER OCCUPIED AND NOT OWNER OCCUPIED SHALL

BE PERMITTED.

EXISTING PROPERTY INFORMATION

COUNCIL DISTRICT NUMBER: 21

DISTRICT COUNCIL MEMBER: BRANDON TAYLOR

PROPERTY OWNER(1): GTOM WEST END, LLC

9010 OVERLOOK BLVD

BRENTWOOD, TN 37027

PROPERTY OWNER(2): TIDMAN, J. HASKELL JR. ET AL

1155 CRATER HILL DRIVE

NASHVILLE, TN 37215

PROPERTY OWNER(3): BAURLE, ERIC J & EADS,

MATTHEW B & ELLIS, TRUITT ETAL

4421 SHEPPARD PL

NASHVILLE, TN 37205

PARCELS & ACREAGE: (PARCELS 016, 131, 132, 133) TOTAL AREA: 37,897 SF [0.87 AC]

(CS = 0.49 AC; MUG-A = 0.38 AC)

EX. BUILDING SF: 22,197 SF

TAX MAP: 104-03, 92-15

METRO GIS ID: 10403001600, 09215013100,

09215013200, 09215013300

STREET ADDRESS: 2416 WEST END AVE, 2413 ELLISTON PL,

2412 WEST END AVE, 2410 WEST END AVE

NASHVILLE, TN 37203

ZONING: OV-UZO, CS (COMMERCIAL SERVICE)

MUG-A (MIXED USE GENERAL -ALTERNATIVE)

EXISTING LAND USE: PARCEL 016: RESTAURANT/VACANT

PARCEL 131: VACANT

PARCEL 132: RESTAURANT

PARCEL 133: RETAIL

COMMUNITY PLAN: GREEN HILLS-MIDTOWN COMMUNITY PLAN

POLICY AREA: 10-MT-T5-MU-01

(T5 CENTER MIXED USE NEIGHBORHOOD AREA 1)

BUILDING SETBACKS

FRONT 0'-15' Measured from back of sidewalkSIDE 0' Measured from back of sidewalkREAR 20'

MAX HEIGHT: 20 STORIES (AND ABOVE)

BUFFER YARDS: N/A

MAX FAR: CS: 0.6; MUG-A: 3.0

MAX ISR: CS: 0.9; MUG-A: 0.9

EXISTING SIDEWALKS:

ELLISTON PLACE: SIDEWALK WIDTH VARIES 8'-10', NO GRASS STRIP

WEST END AVE: SIDEWALK WIDTH VARIES 8'-10', NO GRASS STRIP

PROPOSED DEVELOPMENT SUMMARY

APPLICATION DATE: 06/09/2021

SP NUMBER: 2021SP-045-001

ZONING: SP

LOTS: LOT 1; TOTAL LOT AREA = 37,897 SF (0.87 AC)

PROPOSED LAND USE: ALL USES ALLOWED UNDER MUG-A ZONING

PROPOSED BUILDING

ABOVE GRADE

GROSS AREA (SF): 556,000 SF GROSS BUILDING AREA

MAX SF OF

NON-RESIDENTIAL: NON-RESIDENTIAL MAX SF IS LIMITED TO 70,000 SF.

ABOVE GRADE NON-RESIDENTIAL USES SHALL BE

LOCATED ON LEVELS 1 AND 2. THE TOTAL SQUARE

FOOTAGE SHALL INCLUDE ANY LEASABLE SPACES ABOVE

OR BELOW GRADE ASSOCIATED WITH THE

NON-RESIDENTIAL USES

MAX RESIDENTIAL UNITS: MAXIMUM RESIDENTIAL UNITS = 375 UNITS

(PROPOSED DEVELOPMENT SUMMARY CONTINUED)

STRP (SHORT TERM RENTAL

PROPERTY) NOTE: NON-OWNER OCCUPIED AND OWNER OCCUPIED STRPs

SHALL BE PERMITTED

BULK REGULATIONS:

MIN BUILDING SETBACKS

FRONT 0' Measured from back of sidewalkSIDE 0' Measured from back of sidewalkREAR 0'

MAX BUILDING HEIGHT: THE BUILDING HEIGHT AT THE TALLEST POINT IS 374'-0"

FROM THE LOBBY, NOT INCLUDING THE PARAPET AS

SHOWN ON THE UPDATED ELEVATION. WHEN

MEASURING THE HIGHEST POINT OF THE BUILDING FROM

THE LOWEST ADJACENT STREET GRADE (THE

NORTHEAST CORNER OF THE PROPERTY), THE TALLEST

POINT OF THE BUILDING IS 380'-0" ABOVE STREET GRADE.

MAX BUILDING STORIES: 27 STORIES ABOVE GRADE (MECHANICAL EQUIPMENT

PENTHOUSES ARE NOT INCLUDED)

BUFFER YARDS: N/A

MAX FAR: 15.0 (THE MAX FAR EXCLUDES ALL BELOW GRADE AREAS).

(16.0 MAX FAR IF INCLUDING ALL LEASABLE SPACE

EXCLUDING GARAGE)

MAX ISR: 1.0

PROPOSED SIDEWALKS (PER MCSP):

ELLISTON PLACE (T5-M-AB3): 4' FURNISHING ZONE (4'X6' TREE WELLS), 10' SIDEWALK

WEST END AVE (T5-M-AB6-IM): 4' FURNISHING ZONE (4'X6' TREE WELLS),

10' SIDEWALK, 4' FRONTAGE ZONE

PARKING SUMMARY

REQ. PARKING STATEMENT: BASED ON METRO REQUIREMENTS FOR USES.

[17.20.030 & 17.20.040)

PARKING ADJUSTMENT PER 17.20.040:

17.20.040.G - WITHIN THE URBAN ZONING OVERLAY,

NO PARKING SHALL BE REQUIRED FOR USES LOCATED ON

MULTIMODAL CORRIDORS, AS DESIGNATED IN THE

MAJOR AND COLLECTOR STREET PLAN (MCSP).

THE MCSP DESIGNATES WEST END AVENUE AS A

MULTIMODAL CORRIDOR.

PROPOSED PARKING: 4.5 STORIES BELOW GRADE

REQ. ADA PARKING SPACES: PER CODE

PROP. ADA PARKING SPACES: PER CODE

LOADING SPACE REQ.: PER 17.20.130

LOADING SPACES PROPOSED: SEE PLANS

REQ. BICYCLE STATEMENT: BASED ON METRO REQUIREMENTS [BL2014-714]

(17.20.135)

PROPOSED BICYCLE SPACES: BASED ON METRO REQUIREMENTS [BL2014-714]

(17.20.135)

THE FINAL SP WILL ALLOCATE BIKE PARKING PER THE

CODE WHICH IS DETERMINED BY THE FINAL RESIDENTIAL

UNIT COUNT AND RETAIL SF.

DEVELOPMENT STANDARDS

1. BUILDINGS SHALL AVOID CONTINUOUS UNINTERRUPTED BLANK FACADES. SEE

ARCHITECTURAL ELEVATIONS AND RENDERINGS FOR ADDITIONAL DETAIL.

2. SIDEWALKS SHALL BE CONSTRUCTED TO THE STANDARD OF THE MAJOR AND

COLLECTOR STREET PLAN OR, IF ON A LOCAL STREET, TO LOCAL STREET STANDARDS.

THE BUILD-TO ZONE FOR ALTERNATIVE ZONING DISTRICTS SHALL BE MEASURED SHAll

BE MEASURED FROM THE STANDARD RIGHT-OF-WAY LINE AS ESTABLISHED BY THE

TABLE ENTITLED “STANDARD STREET RIGHT-OF-WAY WIDTHS” IN THE MAJOR AND

COLLECTOR STREET PLAN.

3. THE POTENTIAL PEDESTRIAN ENTRANCES DISPLAYED ON THE SITE LAYOUT PLAN ARE

SUBJECT TO CHANGE IN THE FINAL SP AND TENANT IMPROVEMENT PLANS SUBMITTAL

TO CODES.

GENERAL NOTES

1. ANY STANDARD NOT SPECIFICALLY ADDRESSED HEREIN SHALL COMPLY WITH THE

MUG-A BASE ZONING REQUIREMENTS AS OF THE APPLICATION DATE OF THIS

PRELIMINARY SP.

2. LOT IS TO BE SERVED WITH PUBLIC WATER AND SANITARY SEWER.

3. SITE, OPEN SPACES, WATER QUALITY & DETENTION FACILITIES TO BE MAINTAINED BY

PROPERTY OWNER OR PROPERTY OWNER'S ASSOCIATION.

4. REFUSE COLLECTION, RECYCLING AND MECHANICAL EQUIPMENT SHALL BE FULLY

SCREENED FROM PUBLIC VIEW BY THE COMBINATION OF FENCES, WALLS OR

LANDSCAPING (SECTION 17.24.060 OF THE METRO ZONING CODE).

5. THE DEVELOPER'S FINAL CONSTRUCTION DRAWINGS SHALL COMPLY WITH THE DESIGN

REGULATIONS ESTABLISHED BY THE DEPARTMENT OF PUBLIC WORKS. FINAL DESIGN

MAY VARY BASED ON FIELD CONDITIONS.

6. ALL WORK IN THE PUBLIC RIGHT-OF-WAY REQUIRES A PERMIT FROM THE DEPARTMENT

OF PUBLIC WORKS.

7. STORM WATER WILL BE ROUTED THROUGH A STORMWATER QUALITY MANAGEMENT

SYSTEM, SIZED PER THE DESIGN CRITERIA SET FORTH BY THE METRO STORMWATER

MANAGEMENT MANUAL.

8. APPROVAL OF ANY SPECIFIC PLAN DOES NOT EXEMPT ANY PARCEL SHOWN ON THE

PLAN OR ANY DEVELOPMENT WITHIN THE SP FROM COMPLIANCE WITH ALL PROVISIONS

OF THE METRO ZONING CODE WITH RESPECT TO FLOODPLAIN, STEEP SLOPES,

UNSTABLE SOILS, SINKHOLES, ROCK OUTCROPPINGS, STREAMS, SPRINGS AND

CRITICAL LOTS.

9. IF REQUIRED, A SUBDIVISION PLAT WILL BE SUBMITTED WITH THE FINAL SP

DOCUMENTS.

10. THE FINAL SITE PLAN/ BUILDING PERMIT SITE PLAN SHALL DEPICT THE REQUIRED

PUBLIC SIDEWALKS, ANY REQUIRED GRASS STRIP OR FRONTAGE ZONE AND THE

LOCATION OF ALL EXISTING AND PROPOSED VERTICAL OBSTRUCTIONS WITHIN THE

REQUIRED SIDEWALK AND GRASS STRIP OR FRONTAGE ZONE. PRIOR TO THE

ISSUANCE OF USE AND OCCUPANCY PERMITS, IT SHALL BE CONSIDERED FOR EXISTING

VERTICAL OBSTRUCTIONS TO BE RELOCATED OUTSIDE OF THE REQUIRED SIDEWALK.

VERTICAL OBSTRUCTIONS ARE ONLY PERMITTED WITHIN THE REQUIRED GRASS STRIP

OR FRONTAGE ZONE.

11. BILLBOARDS SHALL NOT BE PERMITTED.

12. SIDEWALK CONSTRUCTION TO COMPLY WITH MCSP. SIDEWALKS ARE TO BE LOCATED

WITHIN DEDICATED R.O.W.

13. FEDERAL COMPLIANCE: ALL DEVELOPMENT WITHIN THE BOUNDARIES OF THIS PLAN

SHALL MEET THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT AND THE

FAIR HOUSING ACT.

ADA: HTTP://WWW.ADA.ORG

US JUSTICE DEPT: HTTP://WWW.JUSTICE.GOV/CRT/HOUSE/FAIRHOUSING/ABOUT_

FAIRHOUSINGACT.HTML

14. 78-840 NOTE: ANY EXCAVATION, FILL OR DISTURBANCE OF THE EXISTING GROUND

ELEVATION MUST BE DONE IN ACCORDANCE WITH STORM WATER MANAGEMENT

ORDINANCE NO. 78/840 AND APPROVED BY THE METROPOLITAN DEPT. OF WATER

SERVICES.

15. ACCESS NOTE: METRO WATER SERVICES SHALL BE PROVIDED SUFFICIENT &

UNENCUMBERED ACCESS IN ORDER TO MAINTAIN AND REPAIR UTILITIES IN THIS SITE.

16. FIRE DEPT. NOTE: FIRE-FLOW SHALL MEET THE REQUIREMENTS OF THE

INTERNATIONAL FIRE CODE - 2012 EDITION; AS AMENDED.

17. PRELIMINARY PLAN NOTE: MINOR MODIFICATIONS TO THIS PRELIMINARY SP PLAN MAY

BE APPROVED BY THE PLANNING COMMISSION OR ITS DESIGNEE BASED UPON FINAL

ARCHITECTURAL, ENGINEERING OR SITE DESIGN AND ACTUAL SITE CONDITIONS. ALL

MODIFICATIONS SHALL BE CONSISTENT WITH THE PRINCIPLES AND FURTHER THE

OBJECTIVES OF THE APPROVED PLAN. MODIFICATIONS SHALL NOT BE PERMITTED,

EXCEPT THROUGH AN ORDINANCE APPROVED BY METRO COUNCIL THAT INCREASE

THE PERMITTED DENSITY OR FLOOR AREA, ADD USES NOT OTHERWISE PERMITTED,

ELIMINATE SPECIFIC CONDITIONS OR REQUIREMENTS CONTAINED IN THE PLAN AS

ADOPTED THROUGH THIS ENACTING ORDINANCE, OR ADD VEHICULAR ACCESS POINTS

NOT CURRENTLY PRESENT OR APPROVED.

18. STORMWATER PRELIMINARY PLAN NOTE: DRAWING IS FOR ILLUSTRATION PURPOSES

TO INDICATE THE BASIC PREMISE OF THE DEVELOPMENT, AS IT PERTAINS TO

STORMWATER APPROVAL / COMMENTS ONLY. THE FINAL LOT COUNT AND DETAILS OF

THE PLAN SHALL BE GOVERNED BY THE APPROPRIATE STORMWATER REGULATIONS AT

THE TIME OF FINAL APPLICATION.

19. FEMA NOTE: NO PORTION OF THIS PARCEL DESCRIBED HEREON LIES WITHIN FLOOD

HAZARD AREA IN ACCORDANCE WITH "INSURANCE RATE MAP PANEL NO. 47037C0243H",

DATED: APRIL 5, 2017 (PANEL NOT PRINTED).

20. SURVEY NOTE: TOPOGRAPHIC INFORMATION AND BOUNDARY INFORMATION TAKEN

FROM SURVEYS PREPARED BY YOUNG - HOBBS AND ASSOCIATES DECEMBER 20, 2020.

21. BUFFER NOTE: THE BUFFER ALONG WATERWAYS WILL BE AN AREA WHERE THE

SURFACE IS LEFT IN A NATURAL STATE IS NOT DISTURBED BY CONSTRUCTION

ACTIVITY. THIS IS IN ACCORDANCE WITH THE STORMWATER MANAGEMENT MANUAL

VOLUME 1 REGULATIONS.

22. C/D NOTE: SIZE DRIVEWAY CULVERTS PER THE DESIGN CRITERIA SET FORTH BY THE

METRO STORMWATER MANAGEMENT MANUAL (MINIMUM DRIVEWAY CULVERT IN METRO

ROW IS 15" CMP).

23. SITE SOILS: THE HYDROLOGIC SOIL GROUP CLASSIFICATION FOR THIS 0.87 LAND AREA

IS McB (MAURY-URBAN LAND COMPLEX, 2 TO 7 PERCENT SLOPES) WHICH IS GROUP B

RATING

24. BALCONIES ARE TO BE ALLOWED.

GENERAL PLAN CONSISTENCY

LAND USE POLICY

THIS SITE IS LOCATED IN THE T5 MU DISTRICT OF THE GREEN HILLS / MIDTOWN

COMMUNITY PLAN. T5 MU IS INTENDED TO MAINTAIN, ENHANCE, AND CREATE

HIGH-INTENSITY URBAN MIXED USE NEIGHBORHOODS WITH A DEVELOPMENT PATTERN

THAT CONTAINS A DIVERSE MIX OF RESIDENTIAL AND NON-RESIDENTIAL LAND USES. T5

MU AREAS ARE INTENDED TO BE AMONG THE MOST INTENSE AREAS IN DAVIDSON COUNTY.

T5 MU AREAS INCLUDE SOME OF NASHVILLE'S MAJOR EMPLOYMENT CENTERS SUCH AS

MIDTOWN THAT REPRESENT SEVERAL SECTORS OF THE ECONOMY INCLUDING HEALTH

CARE, FINANCE, RETAIL, THE MUSIC INDUSTRY, AND LODGING. T5 MU AREAS ALSO

INCLUDE LOCATIONS THAT ARE PLANNED TO EVOLVE TO A SIMILAR FORM AND FUNCTION.

COMMUNITY PLAN COMPLIANCE

THE PROPOSED DEVELOPMENT WILL PROVIDE COMMERCIAL AND RESIDENTIAL LAND USES

TO THE NEARBY LAND USES. ACCESS WITHIN THE OVERALL DEVELOPMENT IS DESIGNED

TO BE PEDESTRIAN FRIENDLY WITH CROSSWALKS AND SIDEWALKS TO PROVIDE SAFE

INTERACTION BETWEEN PEDESTRIAN AND VEHICULAR TRAFFIC. THE BUILDING IS

ORIENTED TOWARDS THE STREET WITH BUILDING FORMS THAT COMPLIMENT THE

ADJACENT NEIGHBORHOODS. LIGHTING WILL BE PROVIDED THROUGHOUT THE

DEVELOPMENT TO PROVIDE SAFETY AT BUILDINGS AND VEHICULAR AND PEDESTRIAN

AREAS WHILE ENHANCING THE CHARACTER OF THE CENTER.

SITE DATA

EXISTING CONDITIONS

SITE LAYOUT PLAN

TRUCK MOVEMENT PLAN

C0.2

C1.1

C1.2

BUILDING ELEVATION - NORTHA01

ARCHITECTURAL PLANS

BUILDING ELEVATION - SOUTHA02

BUILDING ELEVATION - WEST AND EASTA03

CONCEPTUAL RENDERINGSA04

ROOF PLANA228

AutoCAD SHX Text
NTS
Page 2: CONSTRUCTIONNOT FOR

UGE

UGE

UG

EU

GE

UG

E

UGE

UGE

UGE

UGE

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

8''W

8''W

8''W

8''W

G

GG

G

GG

GG

GG

G

GG

G

DYH

DYH

DYH

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

PP

PP

P

PP

PP

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P P

PP

UG

E

UG

E

UG

E

UG

E

UG

E

8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W

WEST END AVE93' R/W AS PER MAPS

12''W

12''W

12''W

12''W

12''W

12''W

12''W

12''W

12''W

12''W

12''W

12''W

FOC FOC

FOC

FOC

FOC

FOC

FOC

FOC

FOC

10''S

10''S

10''S

10''S

10''S

ELLISTON PLACE

71' R/W AS PER MAPS

UGE

UGE

UGE

UGE

UGE

UGE

UG

E

UG

E

UGE

UGE

UGEUGE

UGEUGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

S59°34'22"W 100.97'S59°34'22"W 100.97'

S30°45'49"E 174.86'

N30°35'06"W

89.73'

N44°57'00"E 176.81'

N44°49'05"E 104.29'

S30°45'49"E174.86'

N44°49'05"E 104.29'

S62°23'33"W 63.79' S59°34'22"W 61.65'

Δ=86°40'03"R=10.00'L=15.13'T=9.43'CHD=13.72'N74°19'31"W

Δ=2°49'00"R=750.00'

L=36.87'T=18.44'

CHD=36.87'S60°58'54"W

S30°45'49"E174.86'

ELLIS

TON P

L

G:\2

0203

-208

3\1-

CIV

IL E

NG

INEE

RIN

G\3

-PLA

N S

HEE

TS\2

083

EXIS

T.D

WG

PLO

TTED

BY

BAR

AKA

PATT

ERSO

N O

N: 7

/8/2

021

2:48

PM

LA

ST U

PDAT

ED B

Y BP

ATTE

RSO

N O

N: 7

/8/2

021

10:5

1 AM

Know what'sbelow.before you dig.CallG

:\202

03-2

083\

1-C

IVIL

EN

GIN

EER

ING

\3-P

LAN

SH

EETS

\208

3 EX

IST.

DW

GPL

OTT

ED B

Y BA

RAK

A PA

TTER

SON

ON

: 7/8

/202

1 2:

48 P

M

LAST

UPD

ATED

BY

BPAT

TER

SON

ON

: 7/8

/202

1 10

:51

AM

RSA

N

E

W

METRO CASE #: 2021SP-045-001EXCAVATION PERMIT #: ----------

SWGR PERMIT #: ----------SEWER PROJECT #: ----------BUILDING PERMIT #: ----------

PARCEL IDs: ----------

GreshamSmith.com

Dra

wn

By:

Che

cked

By:

Appr

oved

By:

DATE:PROJECT:

LINE IS 3 INCHES WHEN PRINTED FULL SIZEFULL SHEET SIZE = 34"X44"

222 2nd Avenue South,Nashville, TN 37201

615.770.8100

SEAL

PROJECT

CLIENT

CONSULTANT

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

12/18/2020 1:48:13 PM

BIM

360://44011.00 Circle South R21/44011.01_CS_O

ffice_500K_R21.rvt

20203-2083

06/09/21

Author

Checker

Approver

2416 W

est End

Nashville, D

avidson County, TN

PRELIM

IN

ARY SP

Revision

No. Date Description

METRO

CASE#

2021-SP-045-001

16.29.21 SP Resubmittal

27.08.21 SP Resubmittal

C0.2

EXISTINGCONDITIONS

LEGEND

DY

H

Ü

OWNER: 2400 TNWESTEND AVENUE, LLCADDRESS: 2400 WEST END AVE

PARCEL ID: 09215013700SALE INSTRUMENT: DB-20110103 0000645

OWNER: VANDERBILT UNIVERSITYADDRESS: 2415 VANDERBILT PL

PARCEL ID: 10404000100SALE INSTRUMENT: QC-00006491 0000286

OWNER: DEMETROS, HARRY ET ALADDRESS: 2408 ELLISTON PL

PARCEL ID: 09215005000SALE INSTRUMENT: QC-00007540 0000744

OWNER: H.M. & L.CO., L.P.ADDRESS: 200 25TH AVE NPARCEL ID: 09215004800

SALE INSTRUMENT: QC-00009484 0000261

OWNER: METRO GOV'T P CENTENNIALADDRESS: 2500 WEST END AVE

PARCEL ID: 09214007600SALE INSTRUMENT: DB-00004581 0000964

OWNER: MARSHALL-DONNELLY-COMBSFUNERAL DIRECTOR

ADDRESS: 201 25TH AVE NPARCEL ID: 10403001500

SALE INSTRUMENT: DB-00004596 0000445

Page 3: CONSTRUCTIONNOT FOR

UGE

UGE

UG

E

UG

E

UG

E

U

G

E

U

G

E

U

G

E

U

G

E

F

O

C

FO

C

F

O

C

F

O

C

FO

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

8''W

8''W

8''W

8''W

G

G

G

G

G

G

G

G

G

G

G

G

G

G

D

Y

H

D

Y

H

D

Y

H

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

PP

U

G

E

U

G

E

UG

E

UG

E

UG

E

8''W

8''W

8''W

8''W

8''W

8''W

8''W

8''W

8''W

8''W

8''W

8''W

8''W

8''W 8''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

1

2

''W

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

F

O

C

1

0

''S

1

0

''S

1

0

''S

1

0

''S

1

0

''S

U

G

E

U

G

E

U

G

E

U

G

E

U

G

E

U

G

E

U

G

E

U

G

E

U

G

E

U

G

E

UG

E

UG

E

UGE

UG

E

UGE

UGE

UGE

UGE

UGE

UGEUGE

UGE

UGE

UGE

UGE

WEST END AVE

93' R/W AS PER MAPS

E

L

L

IS

T

O

N

P

L

A

C

E

7

1

' R

/W

A

S

P

E

R

M

A

P

S

W

W

W

S

S

T

S

T

S

T

S

T

W

RAMP DOWN TO PARKING

SHARED TRUCK BAY

SHARED TRUCK BAY

TRASH

TRASH

ONLY

PROPOSED

BUILDING

4' FRONTAGE ZONE

10' CONCRETE SIDEWALK (TYP.)

METRO DWG. No. ST-310

10' CONCRETE SIDEWALK (TYP.)

METRO DWG. No. ST-310

P

L

A

N

T

IN

G

Z

O

N

E

P

U

B

L

IC

S

ID

E

W

A

L

K

D

R

IV

E

L

A

N

E

D

R

IV

E

L

A

N

E

S

P

A

C

E

F

O

R

F

U

T

U

R

E

B

IK

E

L

A

N

E

D

R

IV

E

L

A

N

E

1

0

'

4

'

1

0

'

1

0

'

1

0

'

PLANTING ZONE

PUBLIC SIDEWALK

8

'

10

'4

'1

0.5

'1

0.4

'9

.6

'1

1.1

'9

.5

'1

0.1

'9

.9

'

FRONTAGE ZONE

P

A

R

A

L

L

E

L

P

A

R

K

IN

G

D

R

I

V

E

L

A

N

E

D

R

I

V

E

L

A

N

E

P

L

A

N

T

I

N

G

Z

O

N

E

P

U

B

L

I

C

S

I

D

E

W

A

L

K

10' CONCRETE SIDEWALK (TYP.)

METRO DWG. No. ST-310

4'

EX. DRIVE LANE

EX. DRIVE LANE

EX. DRIVE LANE

EX. DRIVE LANE

EX. DRIVE LANE

EX. DRIVE LANE

EX. DRIVE LANE

(LEFT TURN LANE)

PROPOSED ROW

PROPOSED ROW

COMMERCIAL DRIVEWAY

RAMP ENTRANCE (TYP.)

RIGHT IN, RIGHT OUT

COMMERCIAL DRIVEWAY

RAMP ENTRANCE (TYP.)

RIGHT IN, RIGHT OUT

13'

13'

26'

35'

SP BOUNDARY

5.9

'

6.4

'

5.4'

PROPOSED

STORM SEWER

PROPOSED SITE

STORM SEWER CONNECTION

POINT

PROPOSED

SANITARY SEWER

SERVICE

PROPOSED

WATER SERVICE

5

'

5

'

5

.8

'

PROPOSED

FIRE HYDRANT

PROPOSED

FIRE HYDRANT

EXISTING LOT LINE

EXISTING LOT LINE

BUILDING

OVERHEAD

(TYP.)

2'

3.6'

BUILDING OVERHEAD

(TYP.)

2.8'

STREET TREE

CANOPY (TYP.)

STREET TREE

CANOPY (TYP.)

STREET TREE

UNDERSTORY (TYP.)

STREET TREE

UNDERSTORY (TYP.)

4

3

'

ELLISTON PLACE

CL (CENTER LINE)

WEST END AVE.

CL (CENTER LINE)

51

'

58.9'

4' PLANTING ZONE (TYP.)

103.3'

ELLISTON PLACE

CL (CENTER LINE)

EXISTING POLE TO REMAIN

IN PLANTING ZONE

EXISTING POLE TO REMAIN

IN PLANTING ZONE

EXISTING POLE MAY BE

RELOCATED IF NEEDED

R.O.W.

DEDICATION

R.O.W.

DEDICATION

R.O.W.

DEDICATION

R.O.W.

DEDICATION

R.O.W.

DEDICATION

R.O.W.

DEDICATION

EXISTING WEGO BUS STOP TO BE

BROUGHT UP TO CURRENT STANDARDS

WITHIN THE PUBLIC ROW OF WEST END.

FINAL DETAILS AND LOCATION TO BE

COORDINATED WITH WEGO AT TIME OF

CONSTRUCTION.

8'

55'

5.5'

BUILDING OVERHEAD

(TYP.)

POTENTIAL PEDESTRIAN ENTRANCES

(TYP)

POTENTIAL PEDESTRIAN ENTRANCES

(TYP)

POTENTIAL PEDESTRIAN ENTRANCES

(TYP)

BICYCLE

CROSSWALK

BICYCLE

CROSSWALK

REVISED CURB

LINE

PEDESTRIAN

CROSSWALK

PEDESTRIAN

CROSSWALK

5

'

1

'

5

'

S

P

A

C

E

F

O

R

F

U

T

U

R

E

B

IK

E

L

A

N

E

A

N

D

B

U

F

F

E

R

1

1

'

1

1

'

5

'

4

'

1

0

'

S

P

A

C

E

F

O

R

F

U

T

U

R

E

B

I

K

E

L

A

N

E

A

N

D

B

U

F

F

E

R

PROPOSED

CURB & GUTTER

U

G

E

U

G

E

U

G

E

UGE

UG

E

UG

E

UGE

UGE

U

G

E

ONLY

D

R

I

V

E

L

A

N

E

BICYCLE

CROSSWALK

REVISED CURB

LINE

PEDESTRIAN

CROSSWALK

ENLARGED

PEDESTRIAN

REFUGE ISLAND

RECONFIGURED

MEDIAN

1

1

'

G:\2

02

03

-2

08

3\1

-C

IV

IL E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\2

08

3 L

AY

OU

T.D

WG

PLO

TT

ED

B

Y M

IC

KY

D

OB

SO

N O

N: 8

/1

8/2

02

1 4

:5

8 P

M

LA

ST

U

PD

AT

ED

B

Y M

DO

BS

ON

O

N: 8

/1

8/2

021

4:5

7 P

M

Know what'sbelow.before you dig.Call

G:\2

02

03

-2

08

3\1

-C

IV

IL E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\2

08

3 L

AY

OU

T.D

WG

PLO

TT

ED

B

Y M

IC

KY

D

OB

SO

N O

N: 8

/1

8/2

02

1 4

:5

8 P

M

LA

ST

U

PD

AT

ED

B

Y M

DO

BS

ON

O

N: 8

/1

8/2

021

4:5

7 P

M

R

S

A

N

E

W

METRO CASE #: 2021SP-045-001

EXCAVATION PERMIT #: ----------

SWGR PERMIT #: ----------

SEWER PROJECT #: ----------

BUILDING PERMIT #: ----------

PARCEL IDs: ----------

GreshamSmith.com

Draw

n B

y:

Checked B

y:

Approved B

y:

DATE:

PROJECT:

LINE IS 3 INCHES WHEN PRINTED FULL SIZE

FULL SHEET SIZE = 34"X44"

222 2nd Avenue South,

Nashville, TN 37201

615.770.8100

SEAL

PROJECT

CLIENT

CONSULTANT

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

12/18/2020 1:48:13 PM

BIM

360://44011.00 Circle South R21/44011.01_CS_O

ffice_500K_R21.rvt

20203-2083

08/09/21

Author

Checker

Approver

2416 W

est End

Nashville, D

avidson County, TN

PRELIM

IN

ARY SP

Revision

No. Date Description

METRO

CASE#

2021-SP-045-001

16.29.21 SP Resubmittal

27.08.21 SP Resubmittal

38.05.21 SP Resubmittal

LEGEND

PROPOSED BUILDING

CONCRETE (HEAVY DUTY)

CONCRETE

EXISTING ASPHALT

PROPOSED ASPHALT

EXISTING PROPERTY LINE

PROPOSED PROPERTY LINE

C1.1

SITE LAYOUT PLAN

STORMWATER NOTES:

1. IT IS ANTICIPATED THE PROJECT WILL PROPOSE TO UTILIZE LOW IMPACT

DEVELOPMENT (LID) MEASURES WHERE POSSIBLE, INCLUDING THE

CONSIDERATION OF SOME EXTENT OF URBAN BIORETENTION, GREEN

ROOF, ETC. THE SITE IS LOCATED IN THE T5 MU DISTRICT OF THE GREEN

HILLS / MIDTOWN COMMUNITY PLAN, WHICH PER DEVELOPMENTAL

STANDARDS ARE INTENDED TO BE AMONGST THE MOST INTENSE HIGH

DENSITY DEVELOPMENT AREAS IN DAVIDSON COUNTY. THUS THE

MAJORITY OF THE SITE IS PROPOSED TO BE OCCUPIED BY PROPOSED

BUILDING OR GARAGE LEVEL FOOTPRINT. THEREFORE IF DEEMED

INADEQUATE SPACE IS AVAILABLE TO FULLY SATISFY LID REQUIREMENTS,

THE PROJECT MAY CONSIDER APPLYING FOR A PSQPF OR LID WAIVER TO

ACHIEVE FULL COMPLIANCE.

2. NOTE: ANY EXCAVATION, FILL OR DISTURBANCE OF THE EXISTING

GROUND ELEVATION MUST BE DONE IN ACCORDANCE WITH STORM

WATER MANAGEMENT ORDINANCE NO.78-840 AND APPROVED BY THE

METROPOLITAN DEPARTMENT OF WATER SERVICES..

3. SIZE DRIVEWAY CULVERTS PER THE DESIGN CRITERIA SET FORTH BY THE

METRO STORMWATER MANAGEMENT MANUAL (MINIMUM DRIVEWAY

CULVERT IN METRO R.O.W. IS 15" CMP)

4. METRO WATER SERVICE SHALL BE PROVIDED SUFFICIENT AND

UNENCUMBERED INGRESS AND EGRESS AT ALL TIMES IN ORDER TO

MAINTAIN, REPAIR, REPLACE AND INSPECT ANT STORMWATER FACILITIES

WITHIN THE PROPERTY.

5. ALL LOTS SHALL HAVE INDIVIDUAL WATER AND SEWER SERVICE.

NOTE

THE FINAL SITE PLAN/BUILDING PERMIT SITE PLAN DEPICTS THE REQUIRED PUBLIC

SIDEWALKS, ANY REQUIRED GRASS STRIP OR FRONTAGE ZONE AND THE LOCATION OF ALL

EXISTING AND PROPOSED VERTICAL OBSTRUCTIONS WITHIN THE REQUIRED SIDEWALK AND

GRASS STRIP OR FRONTAGE ZONE. PRIOR TO THE ISSUANCE OF USE AND OCCUPANCY

PERMITS, EXISTING VERTICAL OBSTRUCTIONS SHALL BE RELOCATED OUTSIDE OF THE

REQUIRED SIDEWALK. VERTICAL OBSTRUCTIONS ARE ONLY PERMITTED WITHIN THE

REQUIRED GRASS STRIP OR FRONTAGE ZONE. THERE SHALL BE NO VERTICAL

OBSTRUCTION (UTILITY POLES) BLOCKING PUBLIC SIDEWALKS.

METRO PUBLIC WORKS NOTES

1. THE DEVELOPER'S FINAL CONSTRUCTION DRAWINGS SHALL COMPLY WITH THE DESIGN

REGULATIONS ESTABLISHED BY THE DEPARTMENT OF PUBLIC WORKS, IN EFFECT AT THE

TIME OF THE APPROVAL OF THE PRELIMINARY DEVELOPMENT PLAN OR FINAL

DEVELOPMENT PLAN OR BUILDING PERMIT, AS APPLICABLE. FINAL DESIGN MAY VARY

BASED ON FIELD CONDITIONS.

2. SUBMIT RECORDED COPY OF ROW DEDICATION PRIOR TO BUILDING PERMIT APPROVAL

BY MPW.

AT GRADE AMENITY AREA

(FINAL DESIGNS TO BE ESTABLISHED AT FINAL SP)

LANDSCAPE NOTES:

1. LANDSCAPING AND TREE DENSITY

REQUIREMENTS PER METRO ZONING ORDINANCE.

2. ALL TREES SHALL BE PLANTED A MIN. OF 15' AWAY

FROM ANY UTILITY POLE.

PROPOSED URBAN

BIORETENTION AREA

LANDSCAPE SITE DATA

PROPERTY INFORMATION:

PROJECT NAME: 2416 WEST END PRELIMINARY SP

PARCEL/S ACREAGE: .87± AC [37,897± SF]

STREET ADDRESS: 2416 WEST END

ZONING SP

TREE DENSITY WORKSHEET

ACREAGE (SURVEYED): .79 ± AC.

MINUS BUILDING COVERAGE AREA: .63 ± AC.

EQUALS ADJUSTED ACREAGE: .16 ± AC.

MULTIPLIED BY REQ. TDU/ACRE: x 22

EQUALS REQ. TDU/PROJECT: 3.52

DENSITY UNITS PROVIDED ON ABOVE SCHEDULES

TOTAL TDU FOR PROTECTED TREES: 0

TOTAL TDU FOR NEW TREES: 3.52

TOTAL TDU PROVIDED: 3.55 (STREET TREES)

TOTAL $ TO TREE BANK: N/A

BUFFER REQUIREMENTS

N/A

STREET TREE REQUIREMENTS

WEST END AVE - 236.82 LF OF FRONTAGE

REQUIRED (236.82/40): 6 TREES

PROVIDED: 6 TREES

ELLISTON PLACE - 261.03 LF OF FRONTAGE

REQUIRED (261.03/40): 7 TREES

PROVIDED: 7 TREES

PROPOSED GRASS STRIP

AND TREE WELLS

POTENTIAL PEDESTRIAN

ENTRANCE

MATCH LINE INSERT

SCALE: 1" = 10'

MA

TC

H L

IN

E - S

EE

T

HIS

S

HE

ET

MA

TC

H L

IN

E - S

EE

T

HIS

S

HE

ET

NOTE:

WEST END AVENUE AND 25TH AVENUE INTERSECTION

IMPROVEMENTS DISPLAYED PER TRAFFIC IMPACT STUDY

RECOMMENDATIONS BY KCI TECHNOLOGIES.

AutoCAD SHX Text
30" BRICK
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
NO PARKING SIGN
AutoCAD SHX Text
NO PARKING SIGN
AutoCAD SHX Text
VANDERBILT SIGN
AutoCAD SHX Text
BUS SIGN
AutoCAD SHX Text
BENCH
AutoCAD SHX Text
BIKE ROUTE SIGN
AutoCAD SHX Text
SIGN
AutoCAD SHX Text
SMOOTHIE KING SIGN
AutoCAD SHX Text
BIKE RACK
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
30 MPH SIGN
AutoCAD SHX Text
SIGN
AutoCAD SHX Text
S 59°13'11" W 269.70' (M) S 59°13'48" W 269.75' (R)
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
18"RCP
AutoCAD SHX Text
18"RCP
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
6" PVC
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
30" BRICK
AutoCAD SHX Text
520
AutoCAD SHX Text
521
AutoCAD SHX Text
522
AutoCAD SHX Text
519
AutoCAD SHX Text
518
AutoCAD SHX Text
518
AutoCAD SHX Text
517
AutoCAD SHX Text
516
AutoCAD SHX Text
517
AutoCAD SHX Text
516
AutoCAD SHX Text
517
AutoCAD SHX Text
519
AutoCAD SHX Text
517
AutoCAD SHX Text
521
AutoCAD SHX Text
30" BRICK
AutoCAD SHX Text
517
AutoCAD SHX Text
0
AutoCAD SHX Text
10
AutoCAD SHX Text
20
Page 4: CONSTRUCTIONNOT FOR

WEST END AVE93' R/W AS PER MAPS

ELLISTON PLACE

71' R/W AS PER MAPS

RAMP DOWN TO PARKING

SHARED TRUCK BAY

SHARED TRUCK BAY

TRASH

TRASH

PROPOSEDBUILDING

LOADING AREA

TRASH AREA

WEST END AVE93' R/W AS PER MAPS

ELLISTON PLACE

71' R/W AS PER MAPS

RAMP DOWN TO PARKING

SHARED TRUCK BAY

SHARED TRUCK BAY

TRASH

TRASH

PROPOSEDBUILDING

LOADING AREA

TRASH AREA

G:\2

0203

-208

3\1-

CIV

IL E

NG

INEE

RIN

G\3

-PLA

N S

HEE

TS\2

083

TRU

CK.

DW

GPL

OTT

ED B

Y BA

RAK

A PA

TTER

SON

ON

: 7/8

/202

1 2:

49 P

M

LAST

UPD

ATED

BY

BPAT

TER

SON

ON

: 7/8

/202

1 2:

46 P

M

Know what'sbelow.before you dig.CallG

:\202

03-2

083\

1-C

IVIL

EN

GIN

EER

ING

\3-P

LAN

SH

EETS

\208

3 TR

UC

K.D

WG

PLO

TTED

BY

BAR

AKA

PATT

ERSO

N O

N: 7

/8/2

021

2:49

PM

LA

ST U

PDAT

ED B

Y BP

ATTE

RSO

N O

N: 7

/8/2

021

2:46

PM

RSA

N

E

W

METRO CASE #: 2021SP-045-001EXCAVATION PERMIT #: ----------

SWGR PERMIT #: ----------SEWER PROJECT #: ----------BUILDING PERMIT #: ----------

PARCEL IDs: ----------

GreshamSmith.com

Dra

wn

By:

Che

cked

By:

Appr

oved

By:

DATE:PROJECT:

LINE IS 3 INCHES WHEN PRINTED FULL SIZEFULL SHEET SIZE = 34"X44"

222 2nd Avenue South,Nashville, TN 37201

615.770.8100

SEAL

PROJECT

CLIENT

CONSULTANT

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

12/18/2020 1:48:13 PM

BIM

360://44011.00 Circle South R21/44011.01_CS_O

ffice_500K_R21.rvt

20203-2083

06/09/21

Author

Checker

Approver

2416 W

est End

Nashville, D

avidson County, TN

PRELIM

IN

ARY SP

Revision

No. Date Description

METRO

CASE#

2021-SP-045-001

16.29.21 SP Resubmittal

27.08.21 SP Resubmittal

PROPOSED TRUCKWHEEL PATH (TYP.)

PROPOSED TRUCKBUMPER OVERHANG (TYP.)

PROPOSED TRUCKWHEEL PATH (TYP.)

PROPOSED TRUCKBUMPER OVERHANG (TYP.)

LEGEND

PROPOSED BUILDING

CONCRETE (HEAVY DUTY)

CONCRETEEXISTING ASPHALT

PROPOSED ASPHALT

EXISTING PROPERTY LINEPROPOSED PROPERTY LINE PROPOSED URBAN

BIORETENTION AREA

C1.2

TRUCK MOVMENTPLAN

30

4 20

SU-30 - Single Unit TruckOverall Length 30.000ftOverall Width 8.000ftOverall Body Height 13.500ftMin Body Ground Clearance 1.367ftTrack Width 8.000ftLock-to-lock time 5.00sMax Steering Angle (Virtual) 31.80°

30

4 20

SU-30 - Single Unit TruckOverall Length 30.000ftOverall Width 8.000ftOverall Body Height 13.500ftMin Body Ground Clearance 1.367ftTrack Width 8.000ftLock-to-lock time 5.00sMax Steering Angle (Virtual) 31.80°

AT GRADE AMENITY AREA(FINAL DESIGNS TO BE ESTABLISHED AT FINAL SP)

Page 5: CONSTRUCTIONNOT FOR

TOP OF ROOF 374'-0"*

*HEIGHT DOES NOT INCLUDE PARAPET

MASONRY OR EQUIVALENT

GLASS WINDOW WALL, OR EQUIVALENT

CLEAR GLAZING STOREFRONT, OR EQUIVALENT

MASONRY OR EQUIVALENT

METAL PANEL, OR EQUIVALENT

LVL 27

LVL 17

LVL 16

LVL 15

LVL 14

LVL 13

LVL 12

LVL 11

LVL 10

LVL 09

10

' -

6"

10

' -

6"

10

' -

6"

10

' -

6"

10

' -

6"

10

' -

6"

10

' -

6"

10

' -

6"

12

' -

0"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

PEDESTRIAN ENTRANCES ARE SUBJECT TO CHANGE IN FINAL SP

GreshamSmith.com

Dra

wn B

y:

Checked B

y:

Appro

ved B

y:

222 Second Avenue SouthSuite 1400

Nashville, TN 37201

615.770.8100

This Line is 3 Inches When Printed Full Size

7/8

/20

21

10

:02:1

4 P

MB

IM 3

60

://4

490

4.0

0 G

BT

We

st E

nd R

21

/44

90

4_

210

52

8_G

BT

_W

est_

En

d_

op2

_2

.rvt

ELEVATION

A0144904.00

07.07.2021

Auth

or

Checker

Appro

ver

2416 W

est E

nd A

ve., N

ashvill

e,

Tennessee 3

7203

Revision

No. Date Description

0' 10' 40'20' 60'1" = 20'-0"1

BUILDING ELEVATION - NORTH

Page 6: CONSTRUCTIONNOT FOR

MASONRY OR EQUIVALENT

GLASS WINDOW WALL, OR EQUIVALENT

CLEAR GLAZING STOREFRONT, OR EQUIVALENT

METAL AWNING OR EQUIVALENT

TOP OF ROOF 374'-0"*

*HEIGHT DOES NOT INCLUDE PARAPET

LVL 27

12

' -

0"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

7' -

6"

PEDESTRIAN ENTRANCES ARE SUBJECT TO CHANGE IN FINAL SP

GreshamSmith.com

Dra

wn B

y:

Checked B

y:

Appro

ved B

y:

222 Second Avenue SouthSuite 1400

Nashville, TN 37201

615.770.8100

This Line is 3 Inches When Printed Full Size

7/8

/20

21

10

:02:3

3 P

MB

IM 3

60

://4

490

4.0

0 G

BT

We

st E

nd R

21

/44

90

4_

210

52

8_G

BT

_W

est_

En

d_

op2

_2

.rvt

ELEVATION

A0244904.00

07.07.2021

Auth

or

Checker

Appro

ver

2416 W

est E

nd A

ve., N

ashvill

e,

Tennessee 3

7203

Revision

No. Date Description

0' 10' 40'20' 60'1" = 20'-0"1

BUILDING ELEVATION - SOUTH

Page 7: CONSTRUCTIONNOT FOR

MASONRY OR EQUIVALENT

MASONRY OR EQUIVALENT

MASONRY OR EQUIVALENT

GLASS WINDOW WALL,OR EQUIVALENT

TOP OF ROOF 374'-0"*

*HEIGHT DOES NOT INCLUDE PARAPET

EXTRUDED METAL MULLION

EXTRUDED METAL MULLION

METAL PANEL,OR EQUIVALENT

GLASS WINDOW WALL,OR EQUIVALENT

TOP OF ROOF 374'-0"*

*HEIGHT DOES NOT INCLUDE PARAPET

PEDESTRIAN ENTRANCES ARE SUBJECT TO CHANGE IN FINAL SP

GreshamSmith.com

Dra

wn B

y:

Checked B

y:

Appro

ved B

y:

222 Second Avenue SouthSuite 1400

Nashville, TN 37201

615.770.8100

This Line is 3 Inches When Printed Full Size

7/8

/20

21

10

:02:5

4 P

MB

IM 3

60

://4

490

4.0

0 G

BT

We

st E

nd R

21

/44

90

4_

210

52

8_G

BT

_W

est_

En

d_

op2

_2

.rvt

ELEVATION

A0344904.00

07.07.2021

Auth

or

Checker

Appro

ver

2416 W

est E

nd A

ve., N

ashvill

e,

Tennessee 3

7203

Revision

No. Date Description

1" = 20'-0"1

BUILDING ELEVATION - EAST1" = 20'-0"

2BUILDING ELEVATION - WEST

Page 8: CONSTRUCTIONNOT FOR

GreshamSmith.com

Dra

wn

By:

Che

cked

By:

Appr

oved

By:

222 Second Avenue SouthSuite 1400

Nashville, TN 37201

615.770.8100

This Line is 3 Inches When Printed Full Size

6/29

/202

1 11

:52:

49 A

MBI

M 3

60://

4490

4.00

GBT

Wes

t End

R21

/449

04_2

1052

8_G

BT_W

est_

End_

op2_

2.rv

t

RENDERINGS

A0444904.00

06.03.2021

Auth

or

Che

cker

Appr

over

2416

Wes

t End

Ave

., N

ashv

ille,

Tenn

esse

e 37

203

RevisionNo. Date Description

VIEW FROM WEST END LOOKING NORTHWEST

VIEW FROM WEST END LOOKING EAST

VIEW FROM ELLISTON PLACE LOOKING EAST

Page 9: CONSTRUCTIONNOT FOR

ST

EP

BA

CK

30' - 4

31/3

2"

ST

EP

BA

CK

6' - 1

0"

LVL 09 LVL 10

ST

EP

BA

CK

18' -

4"

ST

EP

BA

CK

12' -

10"

ST

EP

BA

CK

8' -

0"

LVL 11 LVL 12 LVL 13 LVL 14 LVL 15 LVL 16 LVL 17

LVL 27

LVL 03

ELLISTON PLACE

WEST END AVE

GreshamSmith.com

Dra

wn B

y:

Checked B

y:

Appro

ved B

y:

222 Second Avenue SouthSuite 1400

Nashville, TN 37201

615.770.8100

This Line is 3 Inches When Printed Full Size

7/8

/20

21

10

:02:5

6 P

MB

IM 3

60

://4

490

4.0

0 G

BT

We

st E

nd R

21

/44

90

4_

210

52

8_G

BT

_W

est_

En

d_

op2

_2

.rvt

ROOF PLAN

A22844904.00

07.07.2021

Auth

or

Checker

Appro

ver

2416 W

est E

nd A

ve., N

ashvill

e,

Tennessee 3

7203

06.0

3.20

21

Revision

No. Date Description

0' 12'8'4'2'1/16" = 1'-0"1

LEVEL ROOF