copy of plati errection process

Upload: rkmallik

Post on 04-Apr-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 Copy of Plati Errection Process

    1/14

    Span of the suspended bridge 186.67 m

    Dia of

    Cable

    Gross

    Area

    Metalic Area Area

    reduction

    factor

    level deffernce between saddle support 0.00 m 13 132.67 73 0.55

    20 314 74 0.24

    26 530.66 292 0.55

    Live load for bridge=3.18+53/l 3.463924 KN/m 32 803.84 442 0.55

    DL of bridge deck excluding of the cable 0.56 KN/m 36 1017.4 560 0.5540 1256 691 0.55

    For 4-40dia main cable and 2-36 dia hand rail cable 48 1808.6 994.75 0.55

    Cable self wt 0.3338 KN/m

    Total DL 0.8938 KN/m

    DL +LL Combinations for 1.06m walk way 4.357724 KN/m

    9841382433, pramod pokhrel

  • 7/29/2019 Copy of Plati Errection Process

    2/14

    Breaking

    load

    Actual

    breaking

    stress

    Grade of

    fiber

    Strength

    reduction

    factor KN/m

    103 1410.959 1570 0.8987 0.0064

    104 1405.405 1571 0.894593 1.0064

    386 1321.918 1570 0.841986 0.0251

    585 1323.529 1570 0.843012 0.038

    740 1321.429 1570 0.841674 0.0481914 1322.721 1570 0.842497 0.0594

    1315.06 1322 1570 0.84 0.078088

    2.73523

    63.28125

  • 7/29/2019 Copy of Plati Errection Process

    3/14

    Equation of Three point Parabola or Two point and Sag option

    SAG

    X* tan(alfa)-S=Y=ax2+bx

    to evaluate Coefficients 'a' and 'b'

    Origin at Left Support

    Sign Convensions: Vertical ordinate +ve

    Horizontal Span 32.00 m

    Level difference 0.00 m

    First point, A 0.00 0.00

    Second Point, B x y Unit

    32.00 0.00 m

    Third Point,C L h Unit

    32.00 0.00 m

    Expected Maximum Sag,Max 2.00 m

    Adopt sag if length does not match,from

    supplied and polygonal calculation 2.00 m

    Coeff, a 0.01

    Coeff, b -0.25

    Sag,Max 2.00 m From Constant, a

    Sag,Max 2.00 m From Constant, b

    Main cable Rope ID 6X7(6/1)F.C 40.00 mmDia

    Nos of Main cable 1.00 nos

    Wt/100m of the cable 554.00 Kg/100 m 0.06 KN/m

    HORIZONTAL Reaction 3.55 KN

    Length of Cable from polygonal profile Driving horiz m

    PROFILE OF CABLE ON SELF LOAD

    Segmental

    Length,Sqrt((DeltaX)^2+(DeltaY)^2) X Y dy/dx

    Slope

    in

    Radian

    Slope in

    Degree

    Tension

    Incable,KN

    0.00 0.00 -0.25 -0.24 -14.04 3.65

    2.05 2.00 -0.47 -0.22 -0.22 -12.34 3.63

    2.04 4.00 -0.88 -0.19 -0.19 -10.62 3.61

    2.03 6.00 -1.22 -0.16 -0.15 -8.88 3.59

    2.02 8.00 -1.50 -0.13 -0.12 -7.13 3.57

    2.01 10.00 -1.72 -0.09 -0.09 -5.36 3.56

    2.01 12.00 -1.88 -0.06 -0.06 -3.58 3.55

    2.00 14.00 -1.97 -0.03 -0.03 -1.79 3.55

    2.00 16.00 -2.00 0.00 0.00 0.00 3.55

    2.00 18.00 -1.97 0.03 0.03 1.79 3.55

    2.00 20.00 -1.88 0.06 0.06 3.58 3.552.01 22.00 -1.72 0.09 0.09 5.36 3.56

    2.01 24.00 -1.50 0.13 0.12 7.13 3.57

    2.02 26.00 -1.22 0.16 0.15 8.88 3.59

    2.03 28.00 -0.88 0.19 0.19 10.62 3.61

    2.04 30.00 -0.47 0.22 0.22 12.34 3.63

    2.05 32.00 0.00 0.25 0.24 14.04 3.65

    Reaction due to point load

  • 7/29/2019 Copy of Plati Errection Process

    4/14

    span 32.00 m

    sag 2.00 m

    chord length 16.12 m

    Cos 0.12 Radian

    wt to transfer, W 20.00 KN

    Tension in cable, T = W/2 Cos 80.62 KN

    Assume factor of safety for cable 2.00

    Factored tension 161.25 KN

    Tension in cable 164.90

    or use 1- 20 dia cable corresponding to breaking strength of 200 KN

    Tower Design Check

    Tower height 4.00 m

    Resulatant force 164.90 KN

    Inclination of resultant force from vertical tow 21.90 Degree

    0.38 Radian

    Vertical compression in tower 153.01 KN

    Horizontal force in tower top 61.48 KN

    Tower height, h 4.00 m

    Tower base moment, M 245.90 KN-m

    leg to leg distance 0.50 m

    tension or compression in leg 245.90 KN

    Area of 65X65X6 angle 1200.00 mm2

    Tensile strength 180.00 KN

    ompressive force in each leg 38.25 KN

    O O

    W = 20 KN

    T

    2T Cos O

    5500

    7000

    T= 200 KN

    T= 200 KN

    T= 200 KN

    21

    .9

    4000

    400

    150 dia pipe , 8 mm thk

    50 mm dia pin

    ISA75X75X8

    50.8

  • 7/29/2019 Copy of Plati Errection Process

    5/14

    Compression capacity of each leg 96.00 KN

    Tower leg is safe in compression

    Connection of tower leg with pin

    Anchor Block

    Cable tension : 164.90 KN

    Check during breaking of cable

    Cable breaking strength 200.00 KN

    Inclination of angle with horizontal 51.80 Degree

    0.90 Radian

    horizontal force 123.75 KN

    Vertical force 157.11 KN

    wt of the block> 404.62 KN

    volume 20.23 m3Assume, L 3.00

    Bredth, B 2.50

    Height, H 2.70

    Volume 20.23 m3

    Unit wt 20.00 KN/m3

    Wt of the block 404.62 KN

    for frictional coefficient 0.50

    Vertical reaction from ground 247.51 KN

    Resisting frictional force for sliding 123.75 KN

    Driving horizontal force 123.75

    Factor of safety during breaking of cable 1.00

    Block will slide during tension corresponding to brea

    overturning bending moment 333.82 KN-m

    Resisting bending moment 505.78 KN-m

    Factor of safety against overturning 1.52 >1

    Safe

    Check during working load

    Cable tension including impact 164.90 KN

    Inclination of angle with horizontal 51.80 Degree

    0.90 Radian

    horizontal force 102.03 KN

    400

    150 dia pipe , 8 mm thk

    50 mm dia pin

  • 7/29/2019 Copy of Plati Errection Process

    6/14

    Vertical force 129.54 KN

    Wt of the block 404.62 KN

    for frictional coefficient 0.50

    Vertical reaction from ground 275.08 KN

    Resisting frictional force for sliding 137.54 KN

    Driving horizontal force 102.03

    Factor of safety during breaking of cable 1.35 1.5

    Safe against sliding failure

    overturning bending moment 306.10 KN-m

    Resisting bending moment 675.00 KN-m

    Factor of safety against overturning 2.21 >2

    Safe

  • 7/29/2019 Copy of Plati Errection Process

    7/14

    what is this?

    0,0

    2,-0.46875

    4,-0.875

    6,-1.21875

    8,-1.5

    10,-1.71875

    12,-1.875

    14,-1.96875

    16,-2

    18,-1.96875

    20,-1.87522,-1.71875

    24,-1.5

    26,-1.21875

    28,-0.875

    30,-0.46875

    32,0

  • 7/29/2019 Copy of Plati Errection Process

    8/14

    T

  • 7/29/2019 Copy of Plati Errection Process

    9/14

    ing of cable

  • 7/29/2019 Copy of Plati Errection Process

    10/14

    Gross Are

  • 7/29/2019 Copy of Plati Errection Process

    11/14

  • 7/29/2019 Copy of Plati Errection Process

    12/14

  • 7/29/2019 Copy of Plati Errection Process

    13/14

  • 7/29/2019 Copy of Plati Errection Process

    14/14

    Metalic AreArea reduc Breaking loActual Grade of KN/m