copy of plati errection process
TRANSCRIPT
-
7/29/2019 Copy of Plati Errection Process
1/14
Span of the suspended bridge 186.67 m
Dia of
Cable
Gross
Area
Metalic Area Area
reduction
factor
level deffernce between saddle support 0.00 m 13 132.67 73 0.55
20 314 74 0.24
26 530.66 292 0.55
Live load for bridge=3.18+53/l 3.463924 KN/m 32 803.84 442 0.55
DL of bridge deck excluding of the cable 0.56 KN/m 36 1017.4 560 0.5540 1256 691 0.55
For 4-40dia main cable and 2-36 dia hand rail cable 48 1808.6 994.75 0.55
Cable self wt 0.3338 KN/m
Total DL 0.8938 KN/m
DL +LL Combinations for 1.06m walk way 4.357724 KN/m
9841382433, pramod pokhrel
-
7/29/2019 Copy of Plati Errection Process
2/14
Breaking
load
Actual
breaking
stress
Grade of
fiber
Strength
reduction
factor KN/m
103 1410.959 1570 0.8987 0.0064
104 1405.405 1571 0.894593 1.0064
386 1321.918 1570 0.841986 0.0251
585 1323.529 1570 0.843012 0.038
740 1321.429 1570 0.841674 0.0481914 1322.721 1570 0.842497 0.0594
1315.06 1322 1570 0.84 0.078088
2.73523
63.28125
-
7/29/2019 Copy of Plati Errection Process
3/14
Equation of Three point Parabola or Two point and Sag option
SAG
X* tan(alfa)-S=Y=ax2+bx
to evaluate Coefficients 'a' and 'b'
Origin at Left Support
Sign Convensions: Vertical ordinate +ve
Horizontal Span 32.00 m
Level difference 0.00 m
First point, A 0.00 0.00
Second Point, B x y Unit
32.00 0.00 m
Third Point,C L h Unit
32.00 0.00 m
Expected Maximum Sag,Max 2.00 m
Adopt sag if length does not match,from
supplied and polygonal calculation 2.00 m
Coeff, a 0.01
Coeff, b -0.25
Sag,Max 2.00 m From Constant, a
Sag,Max 2.00 m From Constant, b
Main cable Rope ID 6X7(6/1)F.C 40.00 mmDia
Nos of Main cable 1.00 nos
Wt/100m of the cable 554.00 Kg/100 m 0.06 KN/m
HORIZONTAL Reaction 3.55 KN
Length of Cable from polygonal profile Driving horiz m
PROFILE OF CABLE ON SELF LOAD
Segmental
Length,Sqrt((DeltaX)^2+(DeltaY)^2) X Y dy/dx
Slope
in
Radian
Slope in
Degree
Tension
Incable,KN
0.00 0.00 -0.25 -0.24 -14.04 3.65
2.05 2.00 -0.47 -0.22 -0.22 -12.34 3.63
2.04 4.00 -0.88 -0.19 -0.19 -10.62 3.61
2.03 6.00 -1.22 -0.16 -0.15 -8.88 3.59
2.02 8.00 -1.50 -0.13 -0.12 -7.13 3.57
2.01 10.00 -1.72 -0.09 -0.09 -5.36 3.56
2.01 12.00 -1.88 -0.06 -0.06 -3.58 3.55
2.00 14.00 -1.97 -0.03 -0.03 -1.79 3.55
2.00 16.00 -2.00 0.00 0.00 0.00 3.55
2.00 18.00 -1.97 0.03 0.03 1.79 3.55
2.00 20.00 -1.88 0.06 0.06 3.58 3.552.01 22.00 -1.72 0.09 0.09 5.36 3.56
2.01 24.00 -1.50 0.13 0.12 7.13 3.57
2.02 26.00 -1.22 0.16 0.15 8.88 3.59
2.03 28.00 -0.88 0.19 0.19 10.62 3.61
2.04 30.00 -0.47 0.22 0.22 12.34 3.63
2.05 32.00 0.00 0.25 0.24 14.04 3.65
Reaction due to point load
-
7/29/2019 Copy of Plati Errection Process
4/14
span 32.00 m
sag 2.00 m
chord length 16.12 m
Cos 0.12 Radian
wt to transfer, W 20.00 KN
Tension in cable, T = W/2 Cos 80.62 KN
Assume factor of safety for cable 2.00
Factored tension 161.25 KN
Tension in cable 164.90
or use 1- 20 dia cable corresponding to breaking strength of 200 KN
Tower Design Check
Tower height 4.00 m
Resulatant force 164.90 KN
Inclination of resultant force from vertical tow 21.90 Degree
0.38 Radian
Vertical compression in tower 153.01 KN
Horizontal force in tower top 61.48 KN
Tower height, h 4.00 m
Tower base moment, M 245.90 KN-m
leg to leg distance 0.50 m
tension or compression in leg 245.90 KN
Area of 65X65X6 angle 1200.00 mm2
Tensile strength 180.00 KN
ompressive force in each leg 38.25 KN
O O
W = 20 KN
T
2T Cos O
5500
7000
T= 200 KN
T= 200 KN
T= 200 KN
21
.9
4000
400
150 dia pipe , 8 mm thk
50 mm dia pin
ISA75X75X8
50.8
-
7/29/2019 Copy of Plati Errection Process
5/14
Compression capacity of each leg 96.00 KN
Tower leg is safe in compression
Connection of tower leg with pin
Anchor Block
Cable tension : 164.90 KN
Check during breaking of cable
Cable breaking strength 200.00 KN
Inclination of angle with horizontal 51.80 Degree
0.90 Radian
horizontal force 123.75 KN
Vertical force 157.11 KN
wt of the block> 404.62 KN
volume 20.23 m3Assume, L 3.00
Bredth, B 2.50
Height, H 2.70
Volume 20.23 m3
Unit wt 20.00 KN/m3
Wt of the block 404.62 KN
for frictional coefficient 0.50
Vertical reaction from ground 247.51 KN
Resisting frictional force for sliding 123.75 KN
Driving horizontal force 123.75
Factor of safety during breaking of cable 1.00
Block will slide during tension corresponding to brea
overturning bending moment 333.82 KN-m
Resisting bending moment 505.78 KN-m
Factor of safety against overturning 1.52 >1
Safe
Check during working load
Cable tension including impact 164.90 KN
Inclination of angle with horizontal 51.80 Degree
0.90 Radian
horizontal force 102.03 KN
400
150 dia pipe , 8 mm thk
50 mm dia pin
-
7/29/2019 Copy of Plati Errection Process
6/14
Vertical force 129.54 KN
Wt of the block 404.62 KN
for frictional coefficient 0.50
Vertical reaction from ground 275.08 KN
Resisting frictional force for sliding 137.54 KN
Driving horizontal force 102.03
Factor of safety during breaking of cable 1.35 1.5
Safe against sliding failure
overturning bending moment 306.10 KN-m
Resisting bending moment 675.00 KN-m
Factor of safety against overturning 2.21 >2
Safe
-
7/29/2019 Copy of Plati Errection Process
7/14
what is this?
0,0
2,-0.46875
4,-0.875
6,-1.21875
8,-1.5
10,-1.71875
12,-1.875
14,-1.96875
16,-2
18,-1.96875
20,-1.87522,-1.71875
24,-1.5
26,-1.21875
28,-0.875
30,-0.46875
32,0
-
7/29/2019 Copy of Plati Errection Process
8/14
T
-
7/29/2019 Copy of Plati Errection Process
9/14
ing of cable
-
7/29/2019 Copy of Plati Errection Process
10/14
Gross Are
-
7/29/2019 Copy of Plati Errection Process
11/14
-
7/29/2019 Copy of Plati Errection Process
12/14
-
7/29/2019 Copy of Plati Errection Process
13/14
-
7/29/2019 Copy of Plati Errection Process
14/14
Metalic AreArea reduc Breaking loActual Grade of KN/m