CyberMate CRAC
• XRow Row-base Cooling Solution
• XRack Rack-base Cooling Solution
Challenge of Data Center
5kW 7kW 12kW 16kW 20kW 30kW 35kW 40kW 45kW 50kW 55kW 60kW 70kW 80kW 90kW 100kW 110kW 130kW 150kW……
CyberMate SeriesDX:6kW~100kW,CW:35kW~150kW
CyberMate Series Modular CRAC: CW:90kW~220kW
iFreecooling Series Adaptive Multi-jointEnergy Saving System
30kW~100kW
XRow® Row-based CoolingDX :12kW~40kWCW:24kW~66kW
Containerized Data Center Cooling
CW:50kW~300kW
CRU Series CRU:80kW~240kW
XR:30kW~50kWXRack™ Micro-Modular CabinetDX:3kW~20kW
Overview of Cooling Solutions
Electric Reheater
Evo Controllerl Teakm work function (Max. 32 units)l Auto Running/Rotationl RS485 port, Ethernet card with TCP/IP, SNMP communicationl Large screen graphic interfacel GPRS SMS alarm
High efficiency Copeland Scroll Compressor
Electrode Humidifierl Adapt to bad quality waterl Easy disassembly for cleaningl Auto flush processl Low noise water solenoid valvel Intelligent alarm functionl Less power and larger capacity
High efficient EC Fans
Electrical Expension Valve
Highlights of CyberMate CRAC
CyberMate CRAC Outdoor Unit
CyberMate Evo Controller
Multi-Temp. & Humidity Sensing &Remote Monitoring
Evo
Temp. & Hum sensor I/O Card
RS485
Serial Port
GPRS (option)
CAN CAN
CyberMate Evo Controller
Energy efficient
Flexible
Reliable
External motor
“Intelligent” Fan
High performance motor
Backward Fan
Higher static pressure
Compact design
Longer lifetime
Maintenance free
deliver to the customer significant energy savings (30%) due to part load operation
Indoor EC Fan
Reference – China Unicom Beijing Muxiyuan IDC data center
Reference - China Unicom Beijing Yizhuang IDC data center
Reference – Shenzhou Communication IDC
Reference – Kuala Lumpur Monorail Data Center
Reference – Railway GSM-R BTS & Signal Control Room
Reference – Shenzhen Boan Airport Radio Administration Bureau
Reference – Beijing Telecom (Da Jiaoting)
CyberMate CRAC
• XRow Row-base Cooling Solution
• XRack Rack-base Cooling Solution
Content
CyberMate CRAC
Electric Reheater
Evo Controllerl Teakm work function (Max. 32 units)l Auto Running/Rotationl RS485 port, Ethernet card with TCP/IP, SNMP communicationl Large screen graphic interfacel GPRS SMS alarm
Electrode Humidifierl Adapt to bad quality waterl Easy disassembly for cleaningl Auto flush processl Low noise water solenoid valvel Intelligent alarm functionl Less power and larger capacity
High efficient EC Fans
Electrical Expension Valve
Cooling Solution - Closer to the Heat Source
XRow outdoor Unit
Energy efficient
Flexible
Reliable
External motor
“Intelligent” Fan
High performance motor
Backward Fan
Higher static pressure
Compact design
Longer lifetime
Maintenance free
deliver to the customer significant energy savings (30%) due to part load operation
Indoor EC Fan
Large LCD Touch Screen DisplayØ Strong teamwork control
Ø Event Log: large storage alarms history
Ø Unit Diary: Operation data saved every minutes,
can be get through protocol
Ø View status of all cooling units
Ø View system averages of entire cooling unit
network
Ø Multiple level password security
Ø SNMP or TCP/IP interface option
Ø GPRS module option for remote monitoring
EVO Controller
Team-Work Mode: up to 32 units in teamwork mode.
Multi-Temp. & Humidity Sensing &Remote Monitoring
Evo
Temp. & Hum sensor I/O Card
RS485
Serial Port
GPRS (option)
CAN CAN
XRow EVO Controller
“EC” scroll compressorüElectronic controlled DC inverter scroll compressor
üRapid response to rack level heat load fluctuation
üBetter temp control by adapting to the load
üEnvironmentally friendly R410a refrigerant
üImproved reliability by avoiding cycling
üLower operating costs due to more efficient operation
“EC” Scroll Compressor
Ø Dual power supply option
Ø Automatic standby for safety
Ø Close to heat source
Ø CFD application in air
distribution
Ø DC inverter compressor and
Variable cooling output
Ø Advanced EVO Controller
ensure optimum performance;
XRow Advantages
Ø Up to 20~40kW per rack
Ø Flow distribution well
Ø Short air supply distance and
low fan power consumption
Ø High air return temperature
Ø High EER
XRow DX SolutionØ DC inverter scroll compressor
Ø Variable air flow
Ø EEV
Ø Team work function
Ø N+1 fan redundancy
Ø Up to 30kW per rack
RackXROw
RackXROw
Condenser Condenser
XRow CW SolutionØ Dynamic distributionØ Water temperature controlØ Team work functionØ N+1 fan redundancyØ Up to 40kW per rack
RackXROw
RackXROw
CDU
ChillerWater
Reference – Tencent Micro Modular Data Center
Reference – ZTE Micro-modular CDU180+XR030C
Reference – ZTE Micro-modular CDU180+XR030C
Reference – WASU VOD Containerized Data Center
Application – WASU VOD Container Data Center
Reference – Tianjin Containerized Data Center
Reference – Data Center – Sichuan Financial Bureau
DX Technical Specifications
Return Air: 37℃ / 24%RH, EC fansCooling Type DXIndoor Unit Model XR012A XR023A XR040APower Input 380V 3Ph 50Hz 380V 3Ph 50Hz 380V 3Ph 50HzCooling CapacityCooling Capacity - kW 12.4 22.9 40.0 Sensible Cooling Capacity - kW 12.4 22.9 40.0 Cooling + Humidifying + Reheating Indoor Unit FLA –A 16.8 23.4 41.5 Indoor Unit Fan Section Air Flow – CMH 2500 5000 8000Quantity of fans 6 6 3Reheat SectionReheating Capacity – Kw 3 3 6 Humidifier SectionHumidifying Capacity - kg/h 3 3 3 Connection SizesLiquid Line – mm 12.7 12.7 15.88Hot Gas Line – mm 19 19 22Inlet pipe of humidifier (female) G1/2'' G1/2'' G1/2''Condensate Drain -OD, mm 6 6 6Physical DataLength –mm 300 300 600Depth – mm 1080 1080 1080 Height – mm 2000 2000 2000 Weight –kg 120 150 330Input Power Section
Cooling + Humidifying + Reheating Breaker –A 32 32 63Power Cable -mm2 6 6 10
DX Technical Specifications
Return Air: 37℃ / 24%RH, EC fansCooling Type DXIndoor Unit Model XR012A XR023A XR040A
Outdoor Unit SectionOutdoor Unit Model XRC16 XRC27 XRC55Outdoor Unit FLA -A 10.5 15.3 26.4 Physical DataLength -mm 1280 1150 1950 Depth - mm 360 700 700 Height - mm 1260 1520 1520 Weight -kg 90 120 240Input Power Section
Outdoor UnitBreaker -A 32 32 40
Power Cable -mm2 4 4 6
CW Technical Specifications
Return Air: 37℃ / 24%RH, EWT/OWT = 10/15℃, EC fansCooling Type CWIndoor Unit Model XR024C XR066CPower Input 380V 3Ph 50Hz 380V 3Ph 50HzCooling CapacityCooling Capacity - kW 23.9 66.8 Sensible Cooling Capacity - kW 23.9 66.8 Cooling + Humidifying + Reheating Indoor Unit FLA -A 8.0 15.2 Indoor Unit Fan SectionAir Flow - CMH 5000 12000Quantity of fans 6 3Reheat SectionReheating Capacity - kW 3 6 Humidifier SectionHumidifying Capacity - kg/h 3 3Evaporator SectionWater Flow - m3/h 4.1 11.5 Connection SizesInlet pipe of CW - mm 32 42Outlet pipe of CW - mm 32 42Inlet pipe of humidifier (female) G1/2‘’ G1/2‘’Condensate Drain -OD, mm 6 6Physical DataLength -mm 300 600Depth - mm 1080 1080 Height - mm 2000 2000 Weight -kg 155 340Input Power Section
Cooling + Humidifying + ReheatingBreaker -A 16 32Power Cable -mm2 2.5 4
CyberMate CRAC
• XRow Row-base Cooling Solution
• XRack Rack-base Cooling Solution
Content
Rack-based Air Conditioner Cooling Solution
Small & Enterprise data center / server room IT infrastructure of financial branch IT infrastructure of chain business Server room of government branch office Office building in CBD ……
XRackTM is a flexible IT infrastructure solution w/o a separate room and standard
decoration
Combination of Server Rack & Cooling Unit
Cleanness due to the enclosed rack structure
Temperature & humidity control—Fast implementation
Flexibility in location Easy to be re-located Intelligent interface for monitoring Low noise level with compressor in
outdoor unit Saving the space costs
Enclosed Space w/ IT Environmental Standard
Cooling for the rack only vs. the room Air flow design fitting thermal design of server Efficient row-based cooling placed close to the heat
source High EER cooling unit applied Variable cooling capacity output basing on heat load
inside Less ON/OFF for compressor by EC compressor Soft start function with low start current N+1 redundancy for fans
Energy Efficiency Cooling
Smoke Sensor
EVO ControllerMonitor the environment / current / server working conditions of cabinet and provide sound & light alarm
XRow® Row-based Cooling Unit Temperature & Humidity Sensor
Door-open SensorRecord and store door-open record
Water Leakage Sensor
Intelligent PDUPDU assembled with air plugMonitor each electric circuitOne more PDU as optional
Rack-mounted UPS(Optional)
UPS Battery(Optional)
Configuration & Options
Smoke Sensor
EVO Controller
XRow® Row-based Cooling Unit
Temperature & Humidity Sensors
Door-open Sensor
Water Leakage Sensor
Intelligent PDU(Optional)
Rack-mounted UPS(Optional)
UPS Battery(Optional)
Door-open Sensors
XRack Configuration & Options
Standard Configuration Server Rack: 1 rack (42U) Front door: single layer glass, magnetic lock (180kg) X2
Back door: metal door, magnetic lock (180kg) X2
Emergency auto-open-door device X2
Door-open sensor X4
Smoke detection X1
Cooling System X1 Indoor unit: XR005A X1
Condenser unit: XR005C X1
Temperature sensor (supply air) X2
Temperature sensor (return air) X2
Humidity sensor (return air) X1
Water leakage X1
Optional Configuration Condensing pump Humidifier UPS w/ Battery Monitoring modular PDU ATS for dual AC power input Magnetic coded lock (280kg protection)
Configuration of XR005
Stepless condenserü Energy conservation
ü Anticorrosion, long life design
ü Condenser is easy to install,can be
installed on the roof,platform
ü Small volume, light weight
ü Ultra low noise
Reference – DX Outdoor Unit
Reference – XRack
Enterprise“Server Cooler” Data Center
RackRowBasedAC
Hot aisle
Cold aisle
XRack Configurations
Hot aisle
Cold aisle
Rack RowBasedAC
Rack
XRack Configurations
Rack RackRack RackRowBasedAC
Hot aisle
Cold aisle
XRack Configurations
Rack Rack Rack Rack Rack Rack
Hot aisle
Cold aisle
RowBasedAC
RowBasedAC
RowBasedAC
XRack Configurations
Technical Specifications
Thank you!