corridor - public works · 2018. 3. 22. · the installatio對n of this project shall be made in...

2
All drawings and written material appearing herein constitute the original and unpublished work of the architect and may not be duplicated, used or disclosed without the prior written consent of the architect. © 2013 Huntsman Architectural Group ABBREVIATIONS LEGEND GENERAL NOTES YEI ENGINEERS, INC.

Upload: others

Post on 27-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CORRIDOR - Public Works · 2018. 3. 22. · the installatio對n of this project shall be made in compliance with the installation of this project shall be made in compliance with

All drawings and written material appearing herein constitute the

original and unpublished work of the architect and may not be

duplicated, used or disclosed without the prior written consent of

the architect. © 2013 Huntsman Architectural Group

ABBREVIATIONS

LEGENDGENERAL NOTES

YEI ENGINEERS, INC.

AutoCAD SHX Text
FAIR OAKS BRANCH
AutoCAD SHX Text
LIBRARY RENOVATION
AutoCAD SHX Text
FIRST FLOOR
AutoCAD SHX Text
2500 MIDDLEFIELD
AutoCAD SHX Text
REDWOOD CITY, CA
AutoCAD SHX Text
1
AutoCAD SHX Text
06.09.17
AutoCAD SHX Text
PERMIT SET
AutoCAD SHX Text
KX,IA/BH,GC
AutoCAD SHX Text
08.18.17
AutoCAD SHX Text
REVISED PERMIT SET
AutoCAD SHX Text
KX,IA/BH,GC
AutoCAD SHX Text
1
AutoCAD SHX Text
ELECTRICAL LEGEND,
AutoCAD SHX Text
ABBREVIATIONS AND GENERAL NOTES
AutoCAD SHX Text
E001
AutoCAD SHX Text
08.17.16
AutoCAD SHX Text
IA
AutoCAD SHX Text
04.06.16
AutoCAD SHX Text
IA
AutoCAD SHX Text
a
AutoCAD SHX Text
OS
AutoCAD SHX Text
Da
AutoCAD SHX Text
F
AutoCAD SHX Text
OS
AutoCAD SHX Text
S
AutoCAD SHX Text
Da
AutoCAD SHX Text
M
AutoCAD SHX Text
J
AutoCAD SHX Text
P,D
AutoCAD SHX Text
J
AutoCAD SHX Text
P,D
AutoCAD SHX Text
1. EXAMINE ALL DRAWINGS AND FIELD VERIFY (E) ELECTRICAL CONDITIONS EXAMINE ALL DRAWINGS AND FIELD VERIFY (E) ELECTRICAL CONDITIONS INCLUDING VOLTAGES, EXISTING CIRCUITS AND EXACT ROUTING OF ALL CONDUITS AND CONDITIONS IN AND AROUND CONDUIT RUNS. 2. COORDINATE ALL WORK TO AVOID INTERFERENCE BETWEEN ALL TRADES COORDINATE ALL WORK TO AVOID INTERFERENCE BETWEEN ALL TRADES INCLUDING OTHER ONGOING CONSTRUCTION WHICH MAY INTERFERE. 3. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS OR SUPPLEMENTS OF APPLICABLE STATUES, ORDINANCES, CODES OR REGULATIONS OF STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 4. REPORT ANY DISCREPANCY TO ARCHITECT/ENGINEER PRIOR TO ANY WORK. REPORT ANY DISCREPANCY TO ARCHITECT/ENGINEER PRIOR TO ANY WORK. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION AND PROVIDE REPAIR CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION AND PROVIDE REPAIR OF ADJACENT EXISTING SURFACES, AREAS AND PROPERTY THAT MAY BE DAMAGED AS A RESULT OF NEW WORK. 6. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION OF ELECTRICAL EQUIPMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONDUITS, SURFACE-MOUNTED RACEWAYS, FITTINGS AND JUNCTION BOXES TO CONFORM WITH FIELD CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY REINFORCING WALLS AND/OR CEILINGS TO SUPPORT LIGHT FIXTURE WEIGHT. COMPLY WITH APPLICABLE CODES. 7. THE INSTALLATION OF THIS PROJECT SHALL BE MADE IN COMPLIANCE WITH THE INSTALLATION OF THIS PROJECT SHALL BE MADE IN COMPLIANCE WITH THE LATEST EDITIONS OF THE NEC, NECA 1 STANDARD PRACTICE OF GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION, IEEE 3001.5-2013 RECOMMENDED PRACTICE FOR THE APPLICATION OF POWER DISTRIBUTION APPARATUS IN INDUSTRIAL & COMMERCIAL POWER SYSTEMS, IEEE 3003.2-2014 RECOMMENDED PRACTICE FOR EQUIPMENT GROUNDING & BONDING IN INDUSTRIAL & COMMERCIAL POWER SYSTEMS, NATIONAL ELECTRICAL SAFETY CODE OR ANSI STANDARD C2 AND APPLICABLE CODES. 8. ALL RACEWAYS SHALL BE CONCEALED IN CEILINGS AND WALLS. ALL RACEWAYS SHALL BE CONCEALED IN CEILINGS AND WALLS. 9. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND MOUNTING HEIGHTS CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND MOUNTING HEIGHTS PRIOR TO ELECTRICAL EQUIPMENT/DEVICE INSTALLATION. 10. VERIFY EXISTING CIRCUITING PRIOR TO ANY WORK. MAINTAIN POWER TO ALL VERIFY EXISTING CIRCUITING PRIOR TO ANY WORK. MAINTAIN POWER TO ALL UN-AFFECTED AREAS. 11. MAINTAIN ALL BUILDING SECURITY, FIRE ALARM & FIRE PROTECTION SYSTEMS MAINTAIN ALL BUILDING SECURITY, FIRE ALARM & FIRE PROTECTION SYSTEMS AT ALL TIME. 12. ALL CONDUITS PENETRATING THROUGH WALLS SHALL BE SEALED. ALL ALL CONDUITS PENETRATING THROUGH WALLS SHALL BE SEALED. ALL PENETRATIONS SHALL HAVE 6" NOMINAL CLEARANCE FROM ANY CONDUITS, PIPING, FINISHED WALLS, EQUIPMENT, DUCTWORK, ETC. SUBMIT PROPOSED LOCATIONS AND DETAIL SHOWING CLEARANCES FOR ENGINEERING APPROVAL.
AutoCAD SHX Text
A/V AUDIO/VISUAL AUDIO/VISUAL AWG AMERICAN WIRE GAUGE AMERICAN WIRE GAUGE BLDG BUILDING BUILDING C CONDUIT CONDUIT CKT CIRCUIT CIRCUIT CO CONDUIT ONLY CONDUIT ONLY (D) DEMOLITION DEMOLITION DWG(S) DRAWING(S) DRAWING(S) (E) EXISTING EXISTING E/ELEC ELECTRICAL ELECTRICAL FLR FLOOR FLOOR GFI GROUND FAULT INTERRUPTER GROUND FAULT INTERRUPTER GND GROUND GROUND IG ISOLATED GROUND ISOLATED GROUND LTG LIGHTING LIGHTING MIN MINIMUM MINIMUM MAX MAXIMUM MAXIMUM (N) NEW NEW N NEUTRAL NEUTRAL NTS NOT TO SCALE NOT TO SCALE REX READY TO EXIT READY TO EXIT RM ROOM ROOM RCPT RECEPTACLE RECEPTACLE TYP TYPICAL TYPICAL UON UNLESS OTHERWISE NOTED UNLESS OTHERWISE NOTED V VOLTAGE VOLTAGE VFD VARIABLE FREQUENCY DRIVE VARIABLE FREQUENCY DRIVE W WATTAGE WATTAGE WP WEATHERPROOF COVERWEATHERPROOF COVER
AutoCAD SHX Text
DEMOLITION CEILING JUNCTION BOX, LETTER DENOTES POWER (P) OR DATA (D) WALL MOUNTED JUNCTION BOX, LETTER DENOTES POWER (P) OR DATA (D) WALL MOUNTED DUPLEX RECEPTACLE, NEMA 5-20R, +18" AFF, UON. WALL MOUNTED RECEPTACLE WITH GROUND FAULT INTERRUPTER, NEMA 5-20R, +18" AFF, UON. WALL DUPLEX RECEPTACLE WITH MARKED CONTROLLED CIRCUIT PER TITLE 24, NEMA 5-20R, +18" AFF, UON WALL MOUNTED QUADRUPLEX RECEPTACLE, NEMA 5-20R, +18" AFF, UON. RECEPTACLE, NEMA 6-50R, 208V, 50A, +18" AFF, UON FLOOR MOUNTED DUPLEX RECEPTACLE, NEMA 5-20R FLOOR MOUNTED QUADRUPLEX RECEPTACLE, NEMA 5-20R FLOOR MOUNTED QUADRUPLEX RECEPTACLE WITH MARKED CONTROLLED CIRCUIT PER TITLE 24, NEMA 5-20R FLUSHED 480/277 PANELBOARD FLUSHED 208/120V PANELBOARD SURFACE 208/120V PANELBOARD CONCEALED EMT CONDUIT IN WALL OR CEILING, 3/4" MIN. PVC CONDUIT UNDER FLOOR, 1" MIN. 1" CONDUIT STUB UP INTO ACCESSIBLE CEILING OR WALL SPACE, UON. CONDUIT HOMERUN TO PANEL. HASHMARKS INDICATE NUMBER OF CONDUCTORS, 3/4"C MIN. WITH #12 MIN., THHN, CU, 600V, DEDICATED #12 AWG NEUTRAL WIRES, AND 1 GROUND WIRE, UON. HOT A, B, C N (DEDICATED) GND MOTOR SWITCH 20A, SINGLE POLE, 120/277V, +48" TO TOP, UON. LETTER DENOTES SWITCHING CIRCUIT DIMMER SWITCH 20A, SINGLE POLE, 120/277V, +48" TO TOP, UON. LETTER DENOTES SWITCHING CIRCUIT WALL MOUNTED INFRARED OCCUPANCY SENSOR WITH DIMMER SWITCH, +48" TO TOP, LETTER DENOTES SWITCHING CIRCUIT CEILING ULTRASONIC AND INFRARED DUAL OCCUPANCY SENSOR, SHALL CONTROL LIGHTS AND CONTROLLED RECEPTACLE WHEN APPLICABLE PER TITLE 24, LETTER DENOTES SWITCHING CIRCUIT CEILING PHOTOCELL SENSOR MOUNTED CLOSE TO SKYLIGHT OPENING, LETTER DENOTES SWITCHING CIRCUIT VOICE/DATA OUTLET AT WALL, +18" AFF FLOOR QUAD VOICE/DATA OUTLET FIRE ALARM PULL STATION, WALL MOUNT, +48" TO TOP, UON. FIRE ALARM STROBE, WALL MOUNT, +96" TO TOP, UON. LIGHT FIXTURE TAG MOUNTING HEIGHT LIGHT FIXTURE TYPE WATTAGE TRANSFORMER FOB ACCESS, COORDINATE WITH REDWOOD CITY CONSULTANT: JOHN DORNIK ([email protected]) DEMAND METER CIRCUIT BREAKER, SIZE AS INDICATED DELTA-WYE TRANSFORMER
AutoCAD SHX Text
S
AutoCAD SHX Text
a
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
WATTAGE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
A1
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
LIGHT FIXTURE SCHEDULE
AutoCAD SHX Text
A2
AutoCAD SHX Text
RECESSED LED EXIT SIGN IN BRUSHED ALUMINUM HOUSING, CLEAR ACRYLIC BACKGROUND, GREEN LETTERS. ARROW DENOTES DIRECTION OF EGRESS, CONNECTED TO EXISTING EMERGENCY CIRCUIT (LITHONIA #EDGR-G-EL OR APPROVED EQUAL)
AutoCAD SHX Text
277V
AutoCAD SHX Text
28W LED
AutoCAD SHX Text
4' LENGTH RECESSED LED DIRECT LIGHT FIXTURE, EXTRUDED AND MACHINED ALUMINUM, CLEAR ANODIZED FINISH, CLASS 2 CONSTANT CURRENT DIMMING DRIVER VODE 707-Z2-48-AE-2-Z-SO-35-S3
AutoCAD SHX Text
277V
AutoCAD SHX Text
42W LED
AutoCAD SHX Text
SAME AS ABOVE BUT 6' LENGTH VODE 707-Z2-72-AE-2-Z-SO-35-S3
AutoCAD SHX Text
C
AutoCAD SHX Text
277V
AutoCAD SHX Text
45W LED
AutoCAD SHX Text
4.5" SQUARE RECESSED LED DOWNLIGHT, DIE-CAST ALUMINUM HOUSING, DIE-FORMED ALUMINUM REFLECTOR, 0-10V DIMMING DRIVER, 3000L, 3500K COLOR TEMPERATURE FOCAL POINT FLC44D-SO-3000L-277-LD1-T // LC44-SQ-3000L-35K-DN
AutoCAD SHX Text
CX
AutoCAD SHX Text
45W LED
AutoCAD SHX Text
SAME AS ABOVE WITH EMERGENCY BATTERY PACK FOCAL POINT FLC44D-SO-3000L-277-LD1-T-EM // LC44EM-SQ-3000L-35K-DN
AutoCAD SHX Text
277V
AutoCAD SHX Text
X
AutoCAD SHX Text
LED
AutoCAD SHX Text
277V
AutoCAD SHX Text
T
AutoCAD SHX Text
www.yeiengineers.com
AutoCAD SHX Text
7700 Edgewater Drive, Suite 128
AutoCAD SHX Text
Oakland, CA 94621 - (510) 383-1050
AutoCAD SHX Text
a
AutoCAD SHX Text
PS
AutoCAD SHX Text
FOB
AutoCAD SHX Text
GFI
AutoCAD SHX Text
M
AutoCAD SHX Text
30A
AutoCAD SHX Text
EMERGENCY LIGHTING UNIT, INJECTION-MOLDED, FLAME-RETARDENT, HIGH-IMPACT THERMOPLASTIC HOUSING, BATTERY PROVIDES 90 MINUTS OF EMERGENCY POWER (LITHONIA #EU2-LED-M12 OR APPROVED EQUAL)
AutoCAD SHX Text
E
AutoCAD SHX Text
2W LED
AutoCAD SHX Text
277V
AutoCAD SHX Text
1
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
R
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
T
AutoCAD SHX Text
O
AutoCAD SHX Text
F
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
No. E. 14107
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
O
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
O
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
I
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
W
AutoCAD SHX Text
K
AutoCAD SHX Text
C
AutoCAD SHX Text
H
AutoCAD SHX Text
E
AutoCAD SHX Text
U
AutoCAD SHX Text
N
AutoCAD SHX Text
G
aoshaghi
Highlight
aoshaghi
Highlight
aoshaghi
Highlight
aoshaghi
Highlight
Page 2: CORRIDOR - Public Works · 2018. 3. 22. · the installatio對n of this project shall be made in compliance with the installation of this project shall be made in compliance with

CORRIDOR

WAITING AREA

J.I.C.STORAGE

101

119

126 FE

FE

FE

BT

BT

BT

LC LC LC

BT

SCO

P

P

P

SHEET NOTES KEY NOTES

YEI ENGINEERS, INC.

All drawings and written material appearing herein constitute the

original and unpublished work of the architect and may not be

duplicated, used or disclosed without the prior written consent of

the architect. © 2013 Huntsman Architectural Group

14 Quad Floor Receptacle

15 Wall receptacle

6 Existing Data Ports

AutoCAD SHX Text
(E) PANEL LB
AutoCAD SHX Text
(E) PANEL RD
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
J
AutoCAD SHX Text
M
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
EF
AutoCAD SHX Text
4
AutoCAD SHX Text
WH
AutoCAD SHX Text
1
AutoCAD SHX Text
WH
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
GFI
AutoCAD SHX Text
23
AutoCAD SHX Text
25
AutoCAD SHX Text
23
AutoCAD SHX Text
23
AutoCAD SHX Text
15
AutoCAD SHX Text
8
AutoCAD SHX Text
12
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
4
AutoCAD SHX Text
+44"
AutoCAD SHX Text
+44"
AutoCAD SHX Text
+44"
AutoCAD SHX Text
+36"
AutoCAD SHX Text
+36"
AutoCAD SHX Text
+36"
AutoCAD SHX Text
J
AutoCAD SHX Text
8
AutoCAD SHX Text
12
AutoCAD SHX Text
RETHERM OVEN
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text
+60"
AutoCAD SHX Text
+60"
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
+38" TYP OF 3
AutoCAD SHX Text
1,3
AutoCAD SHX Text
5
AutoCAD SHX Text
13
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
SERVER
AutoCAD SHX Text
LAPTOP CHARGERS TYP OF 3
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
21
AutoCAD SHX Text
4
AutoCAD SHX Text
T
AutoCAD SHX Text
RD2-1,3 3/4"C, 2#6, 1#10G
AutoCAD SHX Text
RD2-15,17,19,21,29 1"C, 10#12, 1#12G
AutoCAD SHX Text
25
AutoCAD SHX Text
25
AutoCAD SHX Text
23
AutoCAD SHX Text
25
AutoCAD SHX Text
F
AutoCAD SHX Text
18
AutoCAD SHX Text
18
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(R)
AutoCAD SHX Text
(R)
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
11
AutoCAD SHX Text
9
AutoCAD SHX Text
7
AutoCAD SHX Text
5
AutoCAD SHX Text
(E)
AutoCAD SHX Text
6
AutoCAD SHX Text
6
AutoCAD SHX Text
17
AutoCAD SHX Text
19
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
6
AutoCAD SHX Text
16
AutoCAD SHX Text
16
AutoCAD SHX Text
16
AutoCAD SHX Text
18
AutoCAD SHX Text
22
AutoCAD SHX Text
+48"
AutoCAD SHX Text
COFFEE MAKER
AutoCAD SHX Text
MICROWAVE
AutoCAD SHX Text
TOASTER
AutoCAD SHX Text
RD-16,18,20,22 1"C, 8#12, 1#12G
AutoCAD SHX Text
RD2-4,6,8
AutoCAD SHX Text
14
AutoCAD SHX Text
14
AutoCAD SHX Text
14
AutoCAD SHX Text
J
AutoCAD SHX Text
RD2-10,12,14
AutoCAD SHX Text
12
AutoCAD SHX Text
27
AutoCAD SHX Text
27
AutoCAD SHX Text
27
AutoCAD SHX Text
RD2-5,7,9,24 1"C, 8#12, 1#12G
AutoCAD SHX Text
RD2-23,25,26,27 1"C, 8#12, 1#12G
AutoCAD SHX Text
1
AutoCAD SHX Text
TYP
AutoCAD SHX Text
RD2-2,11,13
AutoCAD SHX Text
LB-3,5
AutoCAD SHX Text
8
AutoCAD SHX Text
3
AutoCAD SHX Text
5
AutoCAD SHX Text
TYP
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
(N) PANEL RD2
AutoCAD SHX Text
T
AutoCAD SHX Text
(E) TRANSFORMER TB (IN CEILING)
AutoCAD SHX Text
(N) DOOR STRIKE
AutoCAD SHX Text
9
AutoCAD SHX Text
(E)
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
12
AutoCAD SHX Text
J
AutoCAD SHX Text
D
AutoCAD SHX Text
J
AutoCAD SHX Text
D
AutoCAD SHX Text
J
AutoCAD SHX Text
D
AutoCAD SHX Text
J
AutoCAD SHX Text
D
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
J
AutoCAD SHX Text
D
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
J
AutoCAD SHX Text
P
AutoCAD SHX Text
J
AutoCAD SHX Text
D
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
11
AutoCAD SHX Text
11
AutoCAD SHX Text
GFI/WP
AutoCAD SHX Text
29
AutoCAD SHX Text
FOB
AutoCAD SHX Text
P
AutoCAD SHX Text
J
AutoCAD SHX Text
FOB
AutoCAD SHX Text
P
AutoCAD SHX Text
J
AutoCAD SHX Text
FOB
AutoCAD SHX Text
P
AutoCAD SHX Text
J
AutoCAD SHX Text
12
AutoCAD SHX Text
12
AutoCAD SHX Text
12
AutoCAD SHX Text
6
AutoCAD SHX Text
(N) TRANSFORMER TB2 (IN CEILING)
AutoCAD SHX Text
13
AutoCAD SHX Text
13
AutoCAD SHX Text
13
AutoCAD SHX Text
24
AutoCAD SHX Text
26
AutoCAD SHX Text
26
AutoCAD SHX Text
14
AutoCAD SHX Text
14
AutoCAD SHX Text
14
AutoCAD SHX Text
TYP
AutoCAD SHX Text
FAIR OAKS BRANCH
AutoCAD SHX Text
LIBRARY RENOVATION
AutoCAD SHX Text
FIRST FLOOR
AutoCAD SHX Text
2500 MIDDLEFIELD
AutoCAD SHX Text
REDWOOD CITY, CA
AutoCAD SHX Text
1
AutoCAD SHX Text
06.09.17
AutoCAD SHX Text
PERMIT SET
AutoCAD SHX Text
KX,IA/BH,GC
AutoCAD SHX Text
08.18.17
AutoCAD SHX Text
REVISED PERMIT SET
AutoCAD SHX Text
KX,IA/BH,GC
AutoCAD SHX Text
1
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
NEW WORK FLOOR PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
E201
AutoCAD SHX Text
N O R T H
AutoCAD SHX Text
1. ALL DEVICES AND EQUIPMENT SHOWN ON THIS DWG ARE NEW, UON. ALL DEVICES AND EQUIPMENT SHOWN ON THIS DWG ARE NEW, UON. 2. CONTRACTOR TO MAINTAIN CONTINUITY AND POWER TO UNAFFECTED CONTRACTOR TO MAINTAIN CONTINUITY AND POWER TO UNAFFECTED EQUIPMENT, DEVICES, ETC. OUTSIDE THE PROJECT BOUNDARIES. 3. ALL SWITCHPLATE COVERS TO BE WHITE IN WHITE WALLS, AND ALMOND IN ALL SWITCHPLATE COVERS TO BE WHITE IN WHITE WALLS, AND ALMOND IN YELLOW WALLS.
AutoCAD SHX Text
PROVIDE 1"C STUB UP INTO CEILING WITH PULL STRING. HOMERUN PLENUM RATED DATA CABLES TO DATA SERVER LOCATION. RELOCATE FIRE ALARM DEVICE AND RECONNECT TO NEAREST (E) FIRE ALARM DEVICE. PROVIDE POWER TO (N) INSTANT WATER HEATER. COORDINATE WITH MECHANICAL. MOUNT (N) QUAD RECEPTACLE INSIDE SERVER BOX. COORDINATE HEIGHT AND LOCATION WITH ARCHITECT. CONTROLLED RECEPTACLE SHALL BE CONTROLLED BY THE SAME OCCUPANCY SENSOR CONTROLLING LIGHTS WITHIN THE SAME ENCLOSED ROOM PER TITLE 24. SEE DWG E202 FOR OCCUPANCY SENSOR LOCATION. CONTROLLED RECEPTACLE SHALL BE LABELED IN FIELD ON EACH DEVICE. PROVIDE (N) 15KVA TRANSFORMER TB2 IN CEILING. SEE SINGLE LINE DIAGRAM ON E002 FOR CONDUIT SIZE INFORMATION. CONFIRM INSTALLATION WITH STRUCTURAL ENGINEERS: [email protected] PROVIDE JUNCTION BOX IN CEILING TO TRANSITION FROM CONCEALED CONDUIT TO TRENCHED RACEWAY. COORDINATE FINAL LOCATION WITH ARCHITECTURAL DWGS. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DWGS. PROVIDE (N) SURFACE MOUNTED PANEL RD2 IN CLOSET. SEE SINGLE LINE DIAGRAM ON E002 FOR ADDITIONAL INFORMATION AND DETAILS. PROVIDE RECESSED FLOOR BOX WITH COMBINED POWER AND DATA OUTLETS (LEGRAND RFB4 OR EQUAL). RELOCATE OUTLETS IN WALL TO COORDINATE WITH WALL DISPLAY UNIT. CHECK LOCATION WITH ARCHITECT. (N) FOB SENSOR AND ALL ADDITIONAL CONNECTIONS SHALL BE PROVIDED BY THE VENDOR. REFER TO DETAIL 2 ON THIS SHEET BY VENDOR. PROVIDE POWER TO (N) JUNCTION BOX ABOVE DOOR FOR SECURITY ACCESS REQUIREMENTS. REFER TO DETAIL 2 ON THIS SHEET BY VENDOR. PROVIDE CONDUIT AS NEEDED. PROVIDE UNDER CARPET CABLING FOR POWER RECEPTACLES & DATA OUTLETS (POWER CABLE:TE#3-553079-1, COMMUNICATIONS CABLE:TE#149919-1, RECEPTACLE KITS:TE#554192-1, LOW PROFILE COMMUNICATIONS FLOOR FITTINGS:TE#555287-1)
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
www.yeiengineers.com
AutoCAD SHX Text
7700 Edgewater Drive, Suite 128
AutoCAD SHX Text
Oakland, CA 94621 - (510) 383-1050
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
R
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
T
AutoCAD SHX Text
O
AutoCAD SHX Text
F
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
No. E. 14107
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
O
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
O
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
I
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
W
AutoCAD SHX Text
K
AutoCAD SHX Text
C
AutoCAD SHX Text
H
AutoCAD SHX Text
E
AutoCAD SHX Text
U
AutoCAD SHX Text
N
AutoCAD SHX Text
G
AutoCAD SHX Text
08.17.16
AutoCAD SHX Text
IA
AutoCAD SHX Text
04.06.16
AutoCAD SHX Text
IA
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
SECURITY ACCESS CONNECTIONS
AutoCAD SHX Text
2
AutoCAD SHX Text
NTS
AutoCAD SHX Text
E201
AutoCAD SHX Text
ELECTRICAL NEW WORK FLOOR PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
E201
AutoCAD SHX Text
2"C FROM PULLBOX TO THE NEXT. HOMERUN TO PANEL RD2
AutoCAD SHX Text
LOCATE ABOVE ACCESSIBLE CEILING
AutoCAD SHX Text
CONTROL VOLTAGE PULLBOX INSTALL ON THE SECURED SIDE
AutoCAD SHX Text
1/2"C TO ACCESS CONTROL PULLBOX
AutoCAD SHX Text
MUD BOX, AT GROUTED DOORS TYP
AutoCAD SHX Text
4S BOX W/ 2-GANG RING FOR CARD READER ON UNSECURE SIDE
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
INSTALL 1/2"C INSIDE THE DOOR FRAME ABOVE THE MIDDLE HINGE. MEASURE DOOR ON SITE.
AutoCAD SHX Text
DOOR SWITCH (DS)
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
1/2"C
AutoCAD SHX Text
REX
AutoCAD SHX Text
J
AutoCAD SHX Text
42"
AutoCAD SHX Text
OMIT REX WHERE HARDWARE PROVIDES EQUIVALENT FUNCTIONALITY IN THE DOOR HANDLE OR PANIC HARDWARE. COMPLY WITH THE CBC 1008.13.4 FOR EXITS CONTROLLED BY MAGNETIC LOCKS.
AutoCAD SHX Text
PROVIDE WIRING TO THE DOOR AND POWER SUPPLIES FOR DOOR LOCK OPERATION
AutoCAD SHX Text
MOUNT REX ON DOOR FRAME OR ON THE WALL 1" ABOVE THE DOOR FRAME - REQUEST DIRECTION FROM THE OWNER'S REPRESENTATIVE PRIOR TO PROCEEDING. FURNISH AND INSTALL ELECTRIC LOCK TRANSFER HINGE AND WIRING WITHIN DOOR.
AutoCAD SHX Text
14
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Rectangle
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Callout
Additional Wall Data/Voice
aoshaghi
Callout
Existing Data here, not shown in plans
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Oval
aoshaghi
Rectangle
aoshaghi
Oval
aoshaghi
Callout
IDF Closet