KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
COVER ASSEMBLIES • CONTROL STATIONS
XCS SERIES
Single Push Button
For other than standard marking, refer to the special feature section of price list.
C18. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Three nameplates supplied (Start/Stop, Blank, Emergency Stop) with XCS maintained push button. Operation – when push button is depressed and contact activated, operator will remain in depressed position
until pulled out in normal position.
Push-Pull Mushroom Maintained
Push Button
Three Mini-Push Button
Double Push Button
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
FEATURES-SPECIFICATIONS
XCS MOMENTARY CONTACT SINGLE PUSH BUTTONCATALOG NUMBER
HUB SIZE DIAGRAM BUTTON COLOR NAMEPLATE MARKINGCOVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU
XCS-0B1XCS-1B1 XCS-4B1 1/2”
Green StartXCS-2B1 XCS-5B1 3/4”
XCS-0B2XCS-1B2 XCS-4B2 1/2”
Red StopXCS-2B2 XCS-5B2 3/4”
XCS-0B3XCS-1B3 XCS-4B3 1/2”
Black SpecifyXCS-2B3 XCS-5B3 3/4”
XCS MOMENTARY CONTACT DOUBLE PUSH BUTTONCATALOG NUMBER
HUB SIZE DIAGRAM BUTTON COLOR NAMEPLATE MARKETINGCOVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU
XCS-0B4XCS-1B4 XCS-4B4 1/2”
Green-Red Start/StopXCS-2B4 XCS-5B4 3/4”
XCS-0B4-UXCS-1B4-U XCS-4B4-U 1/2”
Green-Red Start/StopXCS-2B4-U XCS-5B4-U 3/4”
XCS-0B5XCS-1B5 XCS-4B5 1/2”
Green-Green Start/StartXCS-2B5 XCS-5B5 3/4”
XCS-0B7XCS-1B7 XCS-4B7 1/2”
Black-Black SpecifyXCS-2B7 XCS-5B7 3/4”
XCS MOMENTARY CONTACT DOUBLE PUSH BUTTONCATALOG NUMBER
HUB SIZE DIAGRAM BUTTON COLOR NAMEPLATE MARKETINGCOVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU
XCS-0A8XCS-1A8 XCS-4A8 1/2” Green-Red Start/StopXCS-2A8 XCS-5A8 3/4” Black Specify
XCS-0A9XCS-1A9 XCS-4A9 1/2”
Black SpecifyXCS-2A9 XCS-5A9 3/4”
XCS MAINTAINED CONTACT PUSH PULL MUSHROOM PUSH BUTTON
CATALOG NUMBER (COVER WITH DEVICE) DIAGRAM BUTTON COLOR NAMEPLATE MARKING
XCS-OMMG3 GREEN
XCS-OMMR3 REDXCS-OMMK3 BLACK
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K2L3F22D XCS-42K2L3F22D XCS-45K2L3F22D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3M6G32D XCS-42K3M6G32D XCS-45K3M6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3L6G32D XCS-42K3L6G32D XCS-45K3L6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3R6G32D XCS-42K3R6G32D XCS-45K3R6G32D 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
All key operators are furnished keyed different. If keyed alike is required substitute letter “A” for “D” at end of catalog number. Keys are removable in left position for 2 position selectors and in center position for 3 position selectors. For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Key Operated
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
Pilot Light Double Pilot Light
Pilot LightPush Button
Pilot LightTwo Mini Push Buttons
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
For other than standard marking, refer to the special feature section of price list.
catalog number.
desired, use SWB-14, indicating conduit openings required from chart on page C20 of this section. See page C18 for required transformer suffix. One transformer required for each lamp. For control stations with 1” conduit openings or for multi-gang assemblies, order cover and box as separate components.
FEATURES-SPECIFICATIONS
XCS PILOT LIGHTCATALOG NUMBER
HUB SIZE DIAGRAM LAMP VOLTS LENS COLOR NAMEPLATE MARKINGCOVER WITH
DEVICECOMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU
XCS-0B24-CLXCS-1B24-CL XCS-4B24-CL 1/2”
120V Clear SpecifyXCS-2B24-CL XCS-5B24-CL 3/4”
XCS-0B24-GLXCS-1B24-GL XCS-4B24-GL 1/2”
120V Green SpecifyXCS-2B24-GL XCS-5B24-GL 3/4”
XCS-0B24-RLXCS-1B24-RL XCS-4B24-RL 1/2”
120V Red SpecifyXCS-2B24-RL XCS-5B24-RL 3/4”
XCS DOUBLE PILOT LIGHTCATALOG NUMBER
HUB SIZE DIAGRAM LAMP VOLTS LENS COLOR NAMEPLATE MARKINGCOVER WITH
DEVICECOMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU
XCS-0B30-CLXCS-1B30-CL XCS-4B30-CL 1/2”
120V Clear SpecifyXCS-2B30-CL XCS-5B30-CL 3/4”
XCS-0B30-GLXCS-1B30-GL XCS-4B30-GL 1/2”
120V Green SpecifyXCS-2B30-GL XCS-5B30-GL 3/4”
XCS-0B30-RLXCS-1B30-RL XCS-4B30-RL 1/2”
120V Red SpecifyXCS-2B30-RL XCS-5B30-RL 3/4”
XCS-0B30RL-GLXCS-1B30RL-GL XCS-4B30RL-GL 1/2”
120V Red/Green SpecifyXCS-2B30RL-GL XCS-5B30RL-GL 3/4”
XCS MOMENTARY CONTACT PUSH BUTTON AND PILOT LIGHTCATALOG NUMBER
HUB SIZE DIAGRAM BUTTON COLOR LENS COLORNAMEPLATE MARKING
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU BUTTON LENS
XCS-0B13-CXCS-1B13-C XCS-4B13-C 1/2”
Red Red Stop SpecifyXCS-2B13-C XCS-5B13-C 3/4”
XCS-0B13-0XCS-1B13-0 XCS-4B13-0 1/2”
Green Red Start SpecifyXCS-2B13-0 XCS-5B13-0 3/4”
XCS-0B13-UXCS-1B13-U XCS-4B13-U 1/2”
Black Red Specify SpecifyXCS-2B13-U XCS-5B13-U 3/4”
XCS MOMENTARY CONTACT TWO MINI PUSH BUTTONS AND PILOT LIGHTCATALOG NUMBER
HUB SIZE DIAGRAM BUTTON COLOR LENS COLORNAMEPLATE MARKING
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU BUTTON LENS
XCS-0A15XCS-1A15 XCS-4A15 1/2” Red
RedStop
SpecifyXCS-2A15 XCS-5A15 3/4” 120 VAC Green Start
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
FEATURES-SPECIFICATIONSSelector Switch Key Operated
For other than standard marking, refer to the special feature section of the price list. These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1” conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
For other than standard marking, refer to the special feature section of the price list. These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1” conduit openings or for multi-gang assemblies, order
cover with devices and box as separate components.
* Key removal in all positions for 2 & 3 position key operated selectors. Consult factory for variations.
XCS TWO POSITION SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBERHUB SIZE
TWO POSITION DIAGRAM
NAMEPLATE MARKING
LEFT POSITION RIGHT POSITION
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)LEFT BLOCKS RIGHT BLOCKS LEFT BLOCKS RIGHT BLOCKS
DEAD-END FEED-THRU
XCS-0S2A1XCS-1S2A1 XCS-4S2A1 1/2”
OFF/ONXCS-2S2A1 XCS-5S2A1 3/4”
XCS-0S2A5 XCS-42S2A5 XCS-45S2A5 3/4” OFF/ON
XCS TWO POSITION KEY OPERATED SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBERHUB SIZE
TWO POSITION DIAGRAM
NAMEPLATE MARKING
LEFT POSITION RIGHT POSITION
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)LEFT BLOCKS RIGHT BLOCKS LEFT BLOCKS RIGHT BLOCKS
DEAD-END FEED-THRU
XCS-0K2A1DXCS-1K2A1D XCS-4K2A1D 1/2”
OFF/ONXCS-2K2A1D XCS-5K2A1D 3/4”
XCS-0K2A5D XCS-42K2A5D XCS-45K2A5D 3/4” OFF/ON
XCS THREE POSITION SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBERHUB SIZE
THREE POSITION DIAGRAM
NAMEPLATE MARKING
LEFT POSITION CENTER POSITION RIGHT POSITION
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT BLOCKS
RIGHT BLOCKS
LEFT BLOCKS
RIGHT BLOCKS
LEFT BLOCKS
RIGHT BLOCKSDEAD-END FEED-THRU
XCS-0S3C4XCS-1S3C4 XCS-4S3C4 1/2”
HOAXCS-2S3C4 XCS-5S3C4 3/4”
XCS-0S3C5 XCS-42S3C5 XCS-45S3C5 3/4” HOA
XCS THREE POSITION KEY OPERATED SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBERHUB SIZE
THREE POSITION DIAGRAM
NAMEPLATE MARKING
LEFT POSITION CENTER POSITION RIGHT POSITION
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT BLOCKS
RIGHT BLOCKS
LEFT BLOCKS
RIGHT BLOCKS
LEFT BLOCKS
RIGHT BLOCKSDEAD-END FEED-THRU
XCS-0K3C4DXCS-1K3C4D XCS-4K3C4D 1/2”
HOAXCS-2K3C4D XCS-5K3C4D 3/4”
XCS-0K3C5D XCS-42K3C5D XCS-45K3C5D 3/4” HOA
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
DEVICE BODIES FOR USE WITH XCS / XS / XT COVER ASSEMBLIES
SWB SERIES
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - L R 117 12S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass l, Zones 1 & 2, Groups llB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
Maximum size drilled and tapped opening 1” – Shallow device bodies. Maximum size drilled and tapped opening 1-1/2” – Deep device bodies. SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use
SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13
page for custom conduit information.
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Feed Thru SWB-10-11-12
Dead End SWB-1-2-3
Feed Thru SWB-4-5-6 Dead End
SWB-7-8-9
SWB-32
SWB-42 (3/4” Dead End)
SWB-45 (3/4” Feed Thru)
SWB-48 (Two 1/2”on Bottom)
SWB-49 (Two 3/4”on Bottom)
SWB-21
FEATURES-SPECIFICATIONS SWB DEVICE BODIES AND DIMENSIONSCATALOG NUMBER HUB SIZE
EXTERNAL MOUNTINGLENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-2 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-3 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-4 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-5 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-6 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-7 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-8 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-9 1" 5-7/8”(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-10 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-11 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-12 1" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)
SWB-13 5-1/4"(133) 3-5/8"(92) 2-1/2"(64) 6-1/8"(156) 2-3/8"(60)
SWB-14 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
SWB-17 10-3/8"(264) 3-5/8"(92) 2-1/2"(64) 11-3/8"(289) 2-1/8"(54)
SWB-18 5-1/4"(133) 7-1/8"(181) 3-5/16"(84) 6"(152) 5-3/4"(146)
SWB-19 5-1/4"(133) 10-5/8"(270) 3-5/16"(84) 6"(152) 9-3/16"(233)
SWB-20 5-1/4"(133) 14-1/8"(359) 3-5/16"(84) 6"(152) 12-11/16"(322)
SWB-21 5-1/4"(133) 17-5/8"(448) 3-5/16"(84) 6"(152) 16-3/16"(411)
SWB-32 12"(305) 10-5/8"(270) 3-5/16"(84) 11-1/8"(283) 9-3/16"(233)
SWB-33 10-3/8”(264) 14-1/8"(359) 3-5/16"(84) 11-3/16"(284) 12-3/4"(324)
SWB-34 12"(305) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-38 17-1/8"(435) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-42 3/4" 5-1/4"(133) 3-5/8" (92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-45 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-49 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K2L3F22D XCS-42K2L3F22D XCS-45K2L3F22D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3M6G32D XCS-42K3M6G32D XCS-45K3M6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3L6G32D XCS-42K3L6G32D XCS-45K3L6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3R6G32D XCS-42K3R6G32D XCS-45K3R6G32D 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
All key operators are furnished keyed different. If keyed alike is required substitute letter “A” for “D” at end of catalog number. Keys are removable in left position for 2 position selectors and in center position for 3 position selectors. For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Key Operated
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
Pilot Light Double Pilot Light
Pilot LightPush Button
Pilot LightTwo Mini Push Buttons
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
For other than standard marking, refer to the special feature section of price list.
catalog number.
desired, use SWB-14, indicating conduit openings required from chart on page C20 of this section. See page C18 for required transformer suffix. One transformer required for each lamp. For control stations with 1” conduit openings or for multi-gang assemblies, order cover and box as separate components.
FEATURES-SPECIFICATIONS
XCS PILOT LIGHTCATALOG NUMBER
HUB SIZE DIAGRAM LAMP VOLTS LENS COLOR NAMEPLATE MARKINGCOVER WITH
DEVICECOMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU
XCS-0B24-CLXCS-1B24-CL XCS-4B24-CL 1/2”
120V Clear SpecifyXCS-2B24-CL XCS-5B24-CL 3/4”
XCS-0B24-GLXCS-1B24-GL XCS-4B24-GL 1/2”
120V Green SpecifyXCS-2B24-GL XCS-5B24-GL 3/4”
XCS-0B24-RLXCS-1B24-RL XCS-4B24-RL 1/2”
120V Red SpecifyXCS-2B24-RL XCS-5B24-RL 3/4”
XCS DOUBLE PILOT LIGHTCATALOG NUMBER
HUB SIZE DIAGRAM LAMP VOLTS LENS COLOR NAMEPLATE MARKINGCOVER WITH
DEVICECOMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU
XCS-0B30-CLXCS-1B30-CL XCS-4B30-CL 1/2”
120V Clear SpecifyXCS-2B30-CL XCS-5B30-CL 3/4”
XCS-0B30-GLXCS-1B30-GL XCS-4B30-GL 1/2”
120V Green SpecifyXCS-2B30-GL XCS-5B30-GL 3/4”
XCS-0B30-RLXCS-1B30-RL XCS-4B30-RL 1/2”
120V Red SpecifyXCS-2B30-RL XCS-5B30-RL 3/4”
XCS-0B30RL-GLXCS-1B30RL-GL XCS-4B30RL-GL 1/2”
120V Red/Green SpecifyXCS-2B30RL-GL XCS-5B30RL-GL 3/4”
XCS MOMENTARY CONTACT PUSH BUTTON AND PILOT LIGHTCATALOG NUMBER
HUB SIZE DIAGRAM BUTTON COLOR LENS COLORNAMEPLATE MARKING
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU BUTTON LENS
XCS-0B13-CXCS-1B13-C XCS-4B13-C 1/2”
Red Red Stop SpecifyXCS-2B13-C XCS-5B13-C 3/4”
XCS-0B13-0XCS-1B13-0 XCS-4B13-0 1/2”
Green Red Start SpecifyXCS-2B13-0 XCS-5B13-0 3/4”
XCS-0B13-UXCS-1B13-U XCS-4B13-U 1/2”
Black Red Specify SpecifyXCS-2B13-U XCS-5B13-U 3/4”
XCS MOMENTARY CONTACT TWO MINI PUSH BUTTONS AND PILOT LIGHTCATALOG NUMBER
HUB SIZE DIAGRAM BUTTON COLOR LENS COLORNAMEPLATE MARKING
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)DEAD-END FEED-THRU BUTTON LENS
XCS-0A15XCS-1A15 XCS-4A15 1/2” Red
RedStop
SpecifyXCS-2A15 XCS-5A15 3/4” 120 VAC Green Start
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
FEATURES-SPECIFICATIONSSelector Switch Key Operated
For other than standard marking, refer to the special feature section of the price list. These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1” conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
For other than standard marking, refer to the special feature section of the price list. These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1” conduit openings or for multi-gang assemblies, order
cover with devices and box as separate components.
* Key removal in all positions for 2 & 3 position key operated selectors. Consult factory for variations.
XCS TWO POSITION SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBERHUB SIZE
TWO POSITION DIAGRAM
NAMEPLATE MARKING
LEFT POSITION RIGHT POSITION
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)LEFT BLOCKS RIGHT BLOCKS LEFT BLOCKS RIGHT BLOCKS
DEAD-END FEED-THRU
XCS-0S2A1XCS-1S2A1 XCS-4S2A1 1/2”
OFF/ONXCS-2S2A1 XCS-5S2A1 3/4”
XCS-0S2A5 XCS-42S2A5 XCS-45S2A5 3/4” OFF/ON
XCS TWO POSITION KEY OPERATED SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBERHUB SIZE
TWO POSITION DIAGRAM
NAMEPLATE MARKING
LEFT POSITION RIGHT POSITION
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER)LEFT BLOCKS RIGHT BLOCKS LEFT BLOCKS RIGHT BLOCKS
DEAD-END FEED-THRU
XCS-0K2A1DXCS-1K2A1D XCS-4K2A1D 1/2”
OFF/ONXCS-2K2A1D XCS-5K2A1D 3/4”
XCS-0K2A5D XCS-42K2A5D XCS-45K2A5D 3/4” OFF/ON
XCS THREE POSITION SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBERHUB SIZE
THREE POSITION DIAGRAM
NAMEPLATE MARKING
LEFT POSITION CENTER POSITION RIGHT POSITION
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT BLOCKS
RIGHT BLOCKS
LEFT BLOCKS
RIGHT BLOCKS
LEFT BLOCKS
RIGHT BLOCKSDEAD-END FEED-THRU
XCS-0S3C4XCS-1S3C4 XCS-4S3C4 1/2”
HOAXCS-2S3C4 XCS-5S3C4 3/4”
XCS-0S3C5 XCS-42S3C5 XCS-45S3C5 3/4” HOA
XCS THREE POSITION KEY OPERATED SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBERHUB SIZE
THREE POSITION DIAGRAM
NAMEPLATE MARKING
LEFT POSITION CENTER POSITION RIGHT POSITION
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT BLOCKS
RIGHT BLOCKS
LEFT BLOCKS
RIGHT BLOCKS
LEFT BLOCKS
RIGHT BLOCKSDEAD-END FEED-THRU
XCS-0K3C4DXCS-1K3C4D XCS-4K3C4D 1/2”
HOAXCS-2K3C4D XCS-5K3C4D 3/4”
XCS-0K3C5D XCS-42K3C5D XCS-45K3C5D 3/4” HOA
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
DEVICE BODIES FOR USE WITH XCS / XS / XT COVER ASSEMBLIES
SWB SERIES
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - L R 117 12S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass l, Zones 1 & 2, Groups llB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
Maximum size drilled and tapped opening 1” – Shallow device bodies. Maximum size drilled and tapped opening 1-1/2” – Deep device bodies. SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use
SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13
page for custom conduit information.
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Feed Thru SWB-10-11-12
Dead End SWB-1-2-3
Feed Thru SWB-4-5-6 Dead End
SWB-7-8-9
SWB-32
SWB-42 (3/4” Dead End)
SWB-45 (3/4” Feed Thru)
SWB-48 (Two 1/2”on Bottom)
SWB-49 (Two 3/4”on Bottom)
SWB-21
FEATURES-SPECIFICATIONS SWB DEVICE BODIES AND DIMENSIONSCATALOG NUMBER HUB SIZE
EXTERNAL MOUNTINGLENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-2 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-3 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-4 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-5 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-6 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-7 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-8 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-9 1" 5-7/8”(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-10 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-11 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-12 1" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)
SWB-13 5-1/4"(133) 3-5/8"(92) 2-1/2"(64) 6-1/8"(156) 2-3/8"(60)
SWB-14 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
SWB-17 10-3/8"(264) 3-5/8"(92) 2-1/2"(64) 11-3/8"(289) 2-1/8"(54)
SWB-18 5-1/4"(133) 7-1/8"(181) 3-5/16"(84) 6"(152) 5-3/4"(146)
SWB-19 5-1/4"(133) 10-5/8"(270) 3-5/16"(84) 6"(152) 9-3/16"(233)
SWB-20 5-1/4"(133) 14-1/8"(359) 3-5/16"(84) 6"(152) 12-11/16"(322)
SWB-21 5-1/4"(133) 17-5/8"(448) 3-5/16"(84) 6"(152) 16-3/16"(411)
SWB-32 12"(305) 10-5/8"(270) 3-5/16"(84) 11-1/8"(283) 9-3/16"(233)
SWB-33 10-3/8”(264) 14-1/8"(359) 3-5/16"(84) 11-3/16"(284) 12-3/4"(324)
SWB-34 12"(305) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-38 17-1/8"(435) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-42 3/4" 5-1/4"(133) 3-5/8" (92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-45 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-49 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K2L3F22D XCS-42K2L3F22D XCS-45K2L3F22D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3M6G32D XCS-42K3M6G32D XCS-45K3M6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3L6G32D XCS-42K3L6G32D XCS-45K3L6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3R6G32D XCS-42K3R6G32D XCS-45K3R6G32D 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
All key operators are furnished keyed different. If keyed alike is required substitute letter “A” for “D” at end of catalog number. Keys are removable in left position for 2 position selectors and in center position for 3 position selectors. For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Key Operated
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1” conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Selector Switch
FEATURES-SPECIFICATIONS
XCS SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0S2L3F XCS-42S2L3F XCS-45S2L3F 3/4”
XCS SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0S3M6G XCS-42S3M6G XCS-45S3M6G 3/4”
XCS SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0S3L6G XCS-42S3L6G XCS-45S3L6G 3/4”
XCS SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0S3R6G XCS-42S3R6G XCS-45S3R6G 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K2L3F22D XCS-42K2L3F22D XCS-45K2L3F22D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3M6G32D XCS-42K3M6G32D XCS-45K3M6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3L6G32D XCS-42K3L6G32D XCS-45K3L6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3R6G32D XCS-42K3R6G32D XCS-45K3R6G32D 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
All key operators are furnished keyed different. If keyed alike is required substitute letter “A” for “D” at end of catalog number. Keys are removable in left position for 2 position selectors and in center position for 3 position selectors. For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Key Operated
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
DEVICE BODIES FOR USE WITH XCS / XS / XT COVER ASSEMBLIES
SWB SERIES
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - L R 117 12S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass l, Zones 1 & 2, Groups llB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
Maximum size drilled and tapped opening 1” – Shallow device bodies. Maximum size drilled and tapped opening 1-1/2” – Deep device bodies. SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use
SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13
page for custom conduit information.
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Feed Thru SWB-10-11-12
Dead End SWB-1-2-3
Feed Thru SWB-4-5-6 Dead End
SWB-7-8-9
SWB-32
SWB-42 (3/4” Dead End)
SWB-45 (3/4” Feed Thru)
SWB-48 (Two 1/2”on Bottom)
SWB-49 (Two 3/4”on Bottom)
SWB-21
FEATURES-SPECIFICATIONS SWB DEVICE BODIES AND DIMENSIONSCATALOG NUMBER HUB SIZE
EXTERNAL MOUNTINGLENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-2 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-3 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-4 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-5 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-6 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-7 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-8 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-9 1" 5-7/8”(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-10 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-11 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-12 1" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)
SWB-13 5-1/4"(133) 3-5/8"(92) 2-1/2"(64) 6-1/8"(156) 2-3/8"(60)
SWB-14 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
SWB-17 10-3/8"(264) 3-5/8"(92) 2-1/2"(64) 11-3/8"(289) 2-1/8"(54)
SWB-18 5-1/4"(133) 7-1/8"(181) 3-5/16"(84) 6"(152) 5-3/4"(146)
SWB-19 5-1/4"(133) 10-5/8"(270) 3-5/16"(84) 6"(152) 9-3/16"(233)
SWB-20 5-1/4"(133) 14-1/8"(359) 3-5/16"(84) 6"(152) 12-11/16"(322)
SWB-21 5-1/4"(133) 17-5/8"(448) 3-5/16"(84) 6"(152) 16-3/16"(411)
SWB-32 12"(305) 10-5/8"(270) 3-5/16"(84) 11-1/8"(283) 9-3/16"(233)
SWB-33 10-3/8”(264) 14-1/8"(359) 3-5/16"(84) 11-3/16"(284) 12-3/4"(324)
SWB-34 12"(305) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-38 17-1/8"(435) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-42 3/4" 5-1/4"(133) 3-5/8" (92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-45 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-49 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K2L3F22D XCS-42K2L3F22D XCS-45K2L3F22D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3M6G32D XCS-42K3M6G32D XCS-45K3M6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3L6G32D XCS-42K3L6G32D XCS-45K3L6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3R6G32D XCS-42K3R6G32D XCS-45K3R6G32D 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
All key operators are furnished keyed different. If keyed alike is required substitute letter “A” for “D” at end of catalog number. Keys are removable in left position for 2 position selectors and in center position for 3 position selectors. For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Key Operated
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1” conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Selector Switch
FEATURES-SPECIFICATIONS
XCS SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0S2L3F XCS-42S2L3F XCS-45S2L3F 3/4”
XCS SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0S3M6G XCS-42S3M6G XCS-45S3M6G 3/4”
XCS SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0S3L6G XCS-42S3L6G XCS-45S3L6G 3/4”
XCS SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0S3R6G XCS-42S3R6G XCS-45S3R6G 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K2L3F22D XCS-42K2L3F22D XCS-45K2L3F22D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3M6G32D XCS-42K3M6G32D XCS-45K3M6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3L6G32D XCS-42K3L6G32D XCS-45K3L6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3R6G32D XCS-42K3R6G32D XCS-45K3R6G32D 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
All key operators are furnished keyed different. If keyed alike is required substitute letter “A” for “D” at end of catalog number. Keys are removable in left position for 2 position selectors and in center position for 3 position selectors. For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Key Operated
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
DEVICE BODIES FOR USE WITH XCS / XS / XT COVER ASSEMBLIES
SWB SERIES
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - L R 117 12S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass l, Zones 1 & 2, Groups llB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
Maximum size drilled and tapped opening 1” – Shallow device bodies. Maximum size drilled and tapped opening 1-1/2” – Deep device bodies. SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use
SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13
page for custom conduit information.
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Feed Thru SWB-10-11-12
Dead End SWB-1-2-3
Feed Thru SWB-4-5-6 Dead End
SWB-7-8-9
SWB-32
SWB-42 (3/4” Dead End)
SWB-45 (3/4” Feed Thru)
SWB-48 (Two 1/2”on Bottom)
SWB-49 (Two 3/4”on Bottom)
SWB-21
FEATURES-SPECIFICATIONS SWB DEVICE BODIES AND DIMENSIONSCATALOG NUMBER HUB SIZE
EXTERNAL MOUNTINGLENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-2 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-3 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-4 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-5 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-6 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-7 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-8 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-9 1" 5-7/8”(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-10 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-11 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-12 1" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)
SWB-13 5-1/4"(133) 3-5/8"(92) 2-1/2"(64) 6-1/8"(156) 2-3/8"(60)
SWB-14 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
SWB-17 10-3/8"(264) 3-5/8"(92) 2-1/2"(64) 11-3/8"(289) 2-1/8"(54)
SWB-18 5-1/4"(133) 7-1/8"(181) 3-5/16"(84) 6"(152) 5-3/4"(146)
SWB-19 5-1/4"(133) 10-5/8"(270) 3-5/16"(84) 6"(152) 9-3/16"(233)
SWB-20 5-1/4"(133) 14-1/8"(359) 3-5/16"(84) 6"(152) 12-11/16"(322)
SWB-21 5-1/4"(133) 17-5/8"(448) 3-5/16"(84) 6"(152) 16-3/16"(411)
SWB-32 12"(305) 10-5/8"(270) 3-5/16"(84) 11-1/8"(283) 9-3/16"(233)
SWB-33 10-3/8”(264) 14-1/8"(359) 3-5/16"(84) 11-3/16"(284) 12-3/4"(324)
SWB-34 12"(305) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-38 17-1/8"(435) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-42 3/4" 5-1/4"(133) 3-5/8" (92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-45 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-49 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
XCS SERIES
COVER ASSEMBLIES • CONTROL STATIONS
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – TWO POSITION SPRING RETURN TO LEFTCATALOG NUMBER
HUB SIZETWO POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION RIGHT POSITIONDEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K2L3F22D XCS-42K2L3F22D XCS-45K2L3F22D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT AND LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3M6G32D XCS-42K3M6G32D XCS-45K3M6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM RIGHT, MAINTAIN IN LEFTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3L6G32D XCS-42K3L6G32D XCS-45K3L6G32D 3/4”
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH – THREE POSITION SPRING RETURN TO CENTER FROM LEFT, MAINTAIN IN RIGHTCATALOG NUMBER
HUB SIZE
THREE POSITION DIAGRAM
COVER WITH DEVICE
COMPLETE UNITS (BOX & COVER) LEFT POSITION CENTER POSITION RIGHT POSITION
DEAD-END FEED-THRU LEFT BLOCK RIGHT BLOCK LEFT BLOCK RIGHT
BLOCK LEFT BLOCK RIGHT BLOCK
XCS-0K3R6G32D XCS-42K3R6G32D XCS-45K3R6G32D 3/4”
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - F i l e L R 117 14
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass I, Zones 1 & 2, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
All key operators are furnished keyed different. If keyed alike is required substitute letter “A” for “D” at end of catalog number. Keys are removable in left position for 2 position selectors and in center position for 3 position selectors. For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49. For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Key Operated
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
DEVICE BODIES FOR USE WITH XCS / XS / XT COVER ASSEMBLIES
SWB SERIES
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - L R 117 12S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass l, Zones 1 & 2, Groups llB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
Maximum size drilled and tapped opening 1” – Shallow device bodies. Maximum size drilled and tapped opening 1-1/2” – Deep device bodies. SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use
SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13
page for custom conduit information.
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Feed Thru SWB-10-11-12
Dead End SWB-1-2-3
Feed Thru SWB-4-5-6 Dead End
SWB-7-8-9
SWB-32
SWB-42 (3/4” Dead End)
SWB-45 (3/4” Feed Thru)
SWB-48 (Two 1/2”on Bottom)
SWB-49 (Two 3/4”on Bottom)
SWB-21
FEATURES-SPECIFICATIONS SWB DEVICE BODIES AND DIMENSIONSCATALOG NUMBER HUB SIZE
EXTERNAL MOUNTINGLENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-2 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-3 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-4 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-5 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-6 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-7 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-8 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-9 1" 5-7/8”(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-10 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-11 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-12 1" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)
SWB-13 5-1/4"(133) 3-5/8"(92) 2-1/2"(64) 6-1/8"(156) 2-3/8"(60)
SWB-14 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
SWB-17 10-3/8"(264) 3-5/8"(92) 2-1/2"(64) 11-3/8"(289) 2-1/8"(54)
SWB-18 5-1/4"(133) 7-1/8"(181) 3-5/16"(84) 6"(152) 5-3/4"(146)
SWB-19 5-1/4"(133) 10-5/8"(270) 3-5/16"(84) 6"(152) 9-3/16"(233)
SWB-20 5-1/4"(133) 14-1/8"(359) 3-5/16"(84) 6"(152) 12-11/16"(322)
SWB-21 5-1/4"(133) 17-5/8"(448) 3-5/16"(84) 6"(152) 16-3/16"(411)
SWB-32 12"(305) 10-5/8"(270) 3-5/16"(84) 11-1/8"(283) 9-3/16"(233)
SWB-33 10-3/8”(264) 14-1/8"(359) 3-5/16"(84) 11-3/16"(284) 12-3/4"(324)
SWB-34 12"(305) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-38 17-1/8"(435) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-42 3/4" 5-1/4"(133) 3-5/8" (92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-45 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-49 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK DISTRIBUTION
DIS
TRIBUTION
DIS
TRIBUTION
H A Z LOC
H A Z LOC
COMPACT NON-FUSED DISCONNECT SWITCHES
B7NFD SERIES
Class I, Div. 1 & 2, Groups B, C, DClass l, Zones 1 & 2, Groups llB+ H2, llAClass II, Div. 1 & 2, Groups E, F, GClass IIINEMA 3, 4, 4X, 7 (B, C, D) 9 (E, F, G)
C e r t i fi e d - F i l e L R 117 14
B7NFD1 B7NFD2
Applications
The PRISM® B7 Series of non-fused disconnect switches are used: • In locations made hazardous due to the
presence of flammable gasses or vapors or ignitable dusts, fibers and flyings.
• Outdoors or indoors in damp, wet and dirty locations, or in areas where frequent washdowns, heavy rain or water spray routinely occurs.
• Use as motor circuit disconnect.
PRISM® enclosures universal design accomodates the following manufacturers switches as standard:• Advance Controls 14046 Series• Allen-Bradley 194E Series (B7NFD1 only)• ABB OT Series• Cutler-Hammer C362N Series• Sprecher + Schuh LA7 Series• Ferraz Shawmut LBS Series
Advance Controls © Advance Controls Inc.Allen-Bradley © Rockwell AutomationABB © Tne ABB GroupCutler-Hammer © Eaton CorporationSprecher + Schuh © Sprecher + Schuh
Features
• Compact size enclosures provide application flexibility with cost savings over industry standard sizes
• Fewer cover bolts reduces installation and maintenance time
• Gasketed flange with O-ring located in side bolt circle to seal out moisture
• Rotary handle style operating mechanism with lockout provision as standard
• Removable ductile mounting lugs adjust to irregular mounting surfaces
• Bodies have top and bottom drilled and tapped conduit entrances for power connection, with custom openings available
• ABB UL98 certified switch supplied for 30-100 Amp units
ADAPTER KIT
• Required for Allen-Bradley and Sprecher + Schuh disconnects Order separately B7KIT - NRW
Standard Materials /Finish
• Enclosures: Copper-free aluminum (less than 4/10 of 1% copper content)
• Cover Bolts: 316 Stainless Steel• O-ring Gasket: Silicone• Finish: Grey Powder Polyester painted
exterior, electrostatically applied.• Electrical rating: 600VAC, 30 - 100 Amp
FEATURES-SPECIFICATIONS
MODIFICATIONSSUFFIX
NUMBER DESCRIPTION
KIT-251 100 amp ground lugSU-2 SU-2 Hinge-9 InstalledSU3* Drain & Breather installed (NEMA 7CD)
SU3B* Drain & Breather installed (NEMA 7BCD)SU9 Special paint finish
A 1 NC+1NO AuxiliaryB7SPNPT Change std. conduit size and location
SU14 Fungus proofing of enclosures * NOTE: The installation of a Drain & Breather will
void the NEMA 4-4X ratings of enclosure.
CATALOG NUMBER SWITCH SINGLE PHASE HP THREE PHASE HP DC HPWIRE SIZE** CONDUIT
SIZESENCLOSURE ONLY W/ABB AMPS / PHASE 120VAC 230VAC 208VAC 230VAC 480VAC 600VAC 230VDCB7NFD1 B7NFD13A 30 / 3P 2 5 10 10 20 30 1 #14-10 1 NPTB7NFD2 B7NFD26A 60 / 3P 3 7.5 20 20 40 40 10 #14-4 1-1/2 NPTB7NFD2 B7NFD21A 100 / 3P 5 15 25 30 50 50 20 #8-1 1-1/2 NPT
** Use MN. 75°C wire
DIMENSIONS
ENCLOSUREOUTSIDE BOX DIMENSIONS NOMINAL INSIDE BOX MOUNTING DIMENSIONS
A B C D E F G H I J KB7NFD1 5-3/4 8-1/16 6-5/16 3-5/8 5-13/16 5-1/16 3-1/8 8-1/8 - - 1-1/4B7NFD2 8-1/8 13-1/16 7-13/16 4-1/4 9-3/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16
Fixed Lug Position For B7NFD1Optional Position For B7NFD2
Standard Lug Position For B7NFD2
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
DEVICE BODIES FOR USE WITH XCS / XS / XT COVER ASSEMBLIES
SWB SERIES
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - L R 117 12S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass l, Zones 1 & 2, Groups llB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
Maximum size drilled and tapped opening 1” – Shallow device bodies. Maximum size drilled and tapped opening 1-1/2” – Deep device bodies. SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use
SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13
page for custom conduit information.
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Feed Thru SWB-10-11-12
Dead End SWB-1-2-3
Feed Thru SWB-4-5-6 Dead End
SWB-7-8-9
SWB-32
SWB-42 (3/4” Dead End)
SWB-45 (3/4” Feed Thru)
SWB-48 (Two 1/2”on Bottom)
SWB-49 (Two 3/4”on Bottom)
SWB-21
FEATURES-SPECIFICATIONS SWB DEVICE BODIES AND DIMENSIONSCATALOG NUMBER HUB SIZE
EXTERNAL MOUNTINGLENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-2 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-3 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-4 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-5 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-6 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-7 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-8 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-9 1" 5-7/8”(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-10 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-11 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-12 1" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)
SWB-13 5-1/4"(133) 3-5/8"(92) 2-1/2"(64) 6-1/8"(156) 2-3/8"(60)
SWB-14 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
SWB-17 10-3/8"(264) 3-5/8"(92) 2-1/2"(64) 11-3/8"(289) 2-1/8"(54)
SWB-18 5-1/4"(133) 7-1/8"(181) 3-5/16"(84) 6"(152) 5-3/4"(146)
SWB-19 5-1/4"(133) 10-5/8"(270) 3-5/16"(84) 6"(152) 9-3/16"(233)
SWB-20 5-1/4"(133) 14-1/8"(359) 3-5/16"(84) 6"(152) 12-11/16"(322)
SWB-21 5-1/4"(133) 17-5/8"(448) 3-5/16"(84) 6"(152) 16-3/16"(411)
SWB-32 12"(305) 10-5/8"(270) 3-5/16"(84) 11-1/8"(283) 9-3/16"(233)
SWB-33 10-3/8”(264) 14-1/8"(359) 3-5/16"(84) 11-3/16"(284) 12-3/4"(324)
SWB-34 12"(305) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-38 17-1/8"(435) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-42 3/4" 5-1/4"(133) 3-5/8" (92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-45 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-49 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK DISTRIBUTION
DIS
TRIBUTION
DIS
TRIBUTION
H A Z LOC
H A Z LOC
COMPACT NON-FUSED DISCONNECT SWITCHES
B7NFD SERIES
Class I, Div. 1 & 2, Groups B, C, DClass l, Zones 1 & 2, Groups llB+ H2, llAClass II, Div. 1 & 2, Groups E, F, GClass IIINEMA 3, 4, 4X, 7 (B, C, D) 9 (E, F, G)
C e r t i fi e d - F i l e L R 117 14
B7NFD1 B7NFD2
Applications
The PRISM® B7 Series of non-fused disconnect switches are used: • In locations made hazardous due to the
presence of flammable gasses or vapors or ignitable dusts, fibers and flyings.
• Outdoors or indoors in damp, wet and dirty locations, or in areas where frequent washdowns, heavy rain or water spray routinely occurs.
• Use as motor circuit disconnect.
PRISM® enclosures universal design accomodates the following manufacturers switches as standard:• Advance Controls 14046 Series• Allen-Bradley 194E Series (B7NFD1 only)• ABB OT Series• Cutler-Hammer C362N Series• Sprecher + Schuh LA7 Series• Ferraz Shawmut LBS Series
Advance Controls © Advance Controls Inc.Allen-Bradley © Rockwell AutomationABB © Tne ABB GroupCutler-Hammer © Eaton CorporationSprecher + Schuh © Sprecher + Schuh
Features
• Compact size enclosures provide application flexibility with cost savings over industry standard sizes
• Fewer cover bolts reduces installation and maintenance time
• Gasketed flange with O-ring located in side bolt circle to seal out moisture
• Rotary handle style operating mechanism with lockout provision as standard
• Removable ductile mounting lugs adjust to irregular mounting surfaces
• Bodies have top and bottom drilled and tapped conduit entrances for power connection, with custom openings available
• ABB UL98 certified switch supplied for 30-100 Amp units
ADAPTER KIT
• Required for Allen-Bradley and Sprecher + Schuh disconnects Order separately B7KIT - NRW
Standard Materials /Finish
• Enclosures: Copper-free aluminum (less than 4/10 of 1% copper content)
• Cover Bolts: 316 Stainless Steel• O-ring Gasket: Silicone• Finish: Grey Powder Polyester painted
exterior, electrostatically applied.• Electrical rating: 600VAC, 30 - 100 Amp
FEATURES-SPECIFICATIONS
MODIFICATIONSSUFFIX
NUMBER DESCRIPTION
KIT-251 100 amp ground lugSU-2 SU-2 Hinge-9 InstalledSU3* Drain & Breather installed (NEMA 7CD)
SU3B* Drain & Breather installed (NEMA 7BCD)SU9 Special paint finish
A 1 NC+1NO AuxiliaryB7SPNPT Change std. conduit size and location
SU14 Fungus proofing of enclosures * NOTE: The installation of a Drain & Breather will
void the NEMA 4-4X ratings of enclosure.
CATALOG NUMBER SWITCH SINGLE PHASE HP THREE PHASE HP DC HPWIRE SIZE** CONDUIT
SIZESENCLOSURE ONLY W/ABB AMPS / PHASE 120VAC 230VAC 208VAC 230VAC 480VAC 600VAC 230VDCB7NFD1 B7NFD13A 30 / 3P 2 5 10 10 20 30 1 #14-10 1 NPTB7NFD2 B7NFD26A 60 / 3P 3 7.5 20 20 40 40 10 #14-4 1-1/2 NPTB7NFD2 B7NFD21A 100 / 3P 5 15 25 30 50 50 20 #8-1 1-1/2 NPT
** Use MN. 75°C wire
DIMENSIONS
ENCLOSUREOUTSIDE BOX DIMENSIONS NOMINAL INSIDE BOX MOUNTING DIMENSIONS
A B C D E F G H I J KB7NFD1 5-3/4 8-1/16 6-5/16 3-5/8 5-13/16 5-1/16 3-1/8 8-1/8 - - 1-1/4B7NFD2 8-1/8 13-1/16 7-13/16 4-1/4 9-3/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16
Fixed Lug Position For B7NFD1Optional Position For B7NFD2
Standard Lug Position For B7NFD2
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
DEVICE BODIES FOR USE WITH XCS / XS / XT COVER ASSEMBLIES
SWB SERIES
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - L R 117 12S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass l, Zones 1 & 2, Groups llB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
Maximum size drilled and tapped opening 1” – Shallow device bodies. Maximum size drilled and tapped opening 1-1/2” – Deep device bodies. SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use
SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13
page for custom conduit information.
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Feed Thru SWB-10-11-12
Dead End SWB-1-2-3
Feed Thru SWB-4-5-6 Dead End
SWB-7-8-9
SWB-32
SWB-42 (3/4” Dead End)
SWB-45 (3/4” Feed Thru)
SWB-48 (Two 1/2”on Bottom)
SWB-49 (Two 3/4”on Bottom)
SWB-21
FEATURES-SPECIFICATIONS SWB DEVICE BODIES AND DIMENSIONSCATALOG NUMBER HUB SIZE
EXTERNAL MOUNTINGLENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-2 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-3 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-4 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-5 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-6 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-7 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-8 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-9 1" 5-7/8”(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-10 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-11 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-12 1" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)
SWB-13 5-1/4"(133) 3-5/8"(92) 2-1/2"(64) 6-1/8"(156) 2-3/8"(60)
SWB-14 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
SWB-17 10-3/8"(264) 3-5/8"(92) 2-1/2"(64) 11-3/8"(289) 2-1/8"(54)
SWB-18 5-1/4"(133) 7-1/8"(181) 3-5/16"(84) 6"(152) 5-3/4"(146)
SWB-19 5-1/4"(133) 10-5/8"(270) 3-5/16"(84) 6"(152) 9-3/16"(233)
SWB-20 5-1/4"(133) 14-1/8"(359) 3-5/16"(84) 6"(152) 12-11/16"(322)
SWB-21 5-1/4"(133) 17-5/8"(448) 3-5/16"(84) 6"(152) 16-3/16"(411)
SWB-32 12"(305) 10-5/8"(270) 3-5/16"(84) 11-1/8"(283) 9-3/16"(233)
SWB-33 10-3/8”(264) 14-1/8"(359) 3-5/16"(84) 11-3/16"(284) 12-3/4"(324)
SWB-34 12"(305) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-38 17-1/8"(435) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-42 3/4" 5-1/4"(133) 3-5/8" (92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-45 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-49 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK DISTRIBUTION
DIS
TRIBUTION
DIS
TRIBUTION
H A Z LOC
H A Z LOC
COMPACT NON-FUSED DISCONNECT SWITCHES
B7NFD SERIES
Class I, Div. 1 & 2, Groups B, C, DClass l, Zones 1 & 2, Groups llB+ H2, llAClass II, Div. 1 & 2, Groups E, F, GClass IIINEMA 3, 4, 4X, 7 (B, C, D) 9 (E, F, G)
C e r t i fi e d - F i l e L R 117 14
B7NFD1 B7NFD2
Applications
The PRISM® B7 Series of non-fused disconnect switches are used: • In locations made hazardous due to the
presence of flammable gasses or vapors or ignitable dusts, fibers and flyings.
• Outdoors or indoors in damp, wet and dirty locations, or in areas where frequent washdowns, heavy rain or water spray routinely occurs.
• Use as motor circuit disconnect.
PRISM® enclosures universal design accomodates the following manufacturers switches as standard:• Advance Controls 14046 Series• Allen-Bradley 194E Series (B7NFD1 only)• ABB OT Series• Cutler-Hammer C362N Series• Sprecher + Schuh LA7 Series• Ferraz Shawmut LBS Series
Advance Controls © Advance Controls Inc.Allen-Bradley © Rockwell AutomationABB © Tne ABB GroupCutler-Hammer © Eaton CorporationSprecher + Schuh © Sprecher + Schuh
Features
• Compact size enclosures provide application flexibility with cost savings over industry standard sizes
• Fewer cover bolts reduces installation and maintenance time
• Gasketed flange with O-ring located in side bolt circle to seal out moisture
• Rotary handle style operating mechanism with lockout provision as standard
• Removable ductile mounting lugs adjust to irregular mounting surfaces
• Bodies have top and bottom drilled and tapped conduit entrances for power connection, with custom openings available
• ABB UL98 certified switch supplied for 30-100 Amp units
ADAPTER KIT
• Required for Allen-Bradley and Sprecher + Schuh disconnects Order separately B7KIT - NRW
Standard Materials /Finish
• Enclosures: Copper-free aluminum (less than 4/10 of 1% copper content)
• Cover Bolts: 316 Stainless Steel• O-ring Gasket: Silicone• Finish: Grey Powder Polyester painted
exterior, electrostatically applied.• Electrical rating: 600VAC, 30 - 100 Amp
FEATURES-SPECIFICATIONS
MODIFICATIONSSUFFIX
NUMBER DESCRIPTION
KIT-251 100 amp ground lugSU-2 SU-2 Hinge-9 InstalledSU3* Drain & Breather installed (NEMA 7CD)
SU3B* Drain & Breather installed (NEMA 7BCD)SU9 Special paint finish
A 1 NC+1NO AuxiliaryB7SPNPT Change std. conduit size and location
SU14 Fungus proofing of enclosures * NOTE: The installation of a Drain & Breather will
void the NEMA 4-4X ratings of enclosure.
CATALOG NUMBER SWITCH SINGLE PHASE HP THREE PHASE HP DC HPWIRE SIZE** CONDUIT
SIZESENCLOSURE ONLY W/ABB AMPS / PHASE 120VAC 230VAC 208VAC 230VAC 480VAC 600VAC 230VDCB7NFD1 B7NFD13A 30 / 3P 2 5 10 10 20 30 1 #14-10 1 NPTB7NFD2 B7NFD26A 60 / 3P 3 7.5 20 20 40 40 10 #14-4 1-1/2 NPTB7NFD2 B7NFD21A 100 / 3P 5 15 25 30 50 50 20 #8-1 1-1/2 NPT
** Use MN. 75°C wire
DIMENSIONS
ENCLOSUREOUTSIDE BOX DIMENSIONS NOMINAL INSIDE BOX MOUNTING DIMENSIONS
A B C D E F G H I J KB7NFD1 5-3/4 8-1/16 6-5/16 3-5/8 5-13/16 5-1/16 3-1/8 8-1/8 - - 1-1/4B7NFD2 8-1/8 13-1/16 7-13/16 4-1/4 9-3/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16
Fixed Lug Position For B7NFD1Optional Position For B7NFD2
Standard Lug Position For B7NFD2
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK CONTROLS
H A Z LO C
H A Z LO C
CONTROLS
CONTROLS
DEVICE BODIES FOR USE WITH XCS / XS / XT COVER ASSEMBLIES
SWB SERIES
L i s t e d - F i l e E 5 3 3 6 0
C e r t i fi e d - L R 117 12S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
Class I, Div. 1 & 2, Groups C, DClass l, Zones 1 & 2, Groups llB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IllNEMA 7 (C, D) 9 (E, F, G)
Maximum size drilled and tapped opening 1” – Shallow device bodies. Maximum size drilled and tapped opening 1-1/2” – Deep device bodies. SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included. Use
SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information. SWB-13
page for custom conduit information.
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Feed Thru SWB-10-11-12
Dead End SWB-1-2-3
Feed Thru SWB-4-5-6 Dead End
SWB-7-8-9
SWB-32
SWB-42 (3/4” Dead End)
SWB-45 (3/4” Feed Thru)
SWB-48 (Two 1/2”on Bottom)
SWB-49 (Two 3/4”on Bottom)
SWB-21
FEATURES-SPECIFICATIONS SWB DEVICE BODIES AND DIMENSIONSCATALOG NUMBER HUB SIZE
EXTERNAL MOUNTINGLENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-2 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-3 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-4 1/2" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-5 3/4" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-6 1" 5-7/8"(149) 3"(76) 2-1/4"(57) 5-3/8"(137) 2-3/8"(60)SWB-7 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-8 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-9 1" 5-7/8”(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-10 1/2" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-11 3/4" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)SWB-12 1" 5-7/8"(149) 6-1/2"(165) 2-1/4"(57) 5-3/8"(137) 2-1/2"(64)
SWB-13 5-1/4"(133) 3-5/8"(92) 2-1/2"(64) 6-1/8"(156) 2-3/8"(60)
SWB-14 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
SWB-17 10-3/8"(264) 3-5/8"(92) 2-1/2"(64) 11-3/8"(289) 2-1/8"(54)
SWB-18 5-1/4"(133) 7-1/8"(181) 3-5/16"(84) 6"(152) 5-3/4"(146)
SWB-19 5-1/4"(133) 10-5/8"(270) 3-5/16"(84) 6"(152) 9-3/16"(233)
SWB-20 5-1/4"(133) 14-1/8"(359) 3-5/16"(84) 6"(152) 12-11/16"(322)
SWB-21 5-1/4"(133) 17-5/8"(448) 3-5/16"(84) 6"(152) 16-3/16"(411)
SWB-32 12"(305) 10-5/8"(270) 3-5/16"(84) 11-1/8"(283) 9-3/16"(233)
SWB-33 10-3/8”(264) 14-1/8"(359) 3-5/16"(84) 11-3/16"(284) 12-3/4"(324)
SWB-34 12"(305) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-38 17-1/8"(435) 17-3/4"(451) 3-5/16"(84) 11-5/16"(287) 16-1/4"(413)
SWB-42 3/4" 5-1/4"(133) 3-5/8" (92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-45 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)SWB-49 3/4" 5-1/4"(133) 3-5/8"(92) 3-5/16"(84) 6-1/8"(156) 2-3/8"(60)
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK DISTRIBUTION
DIS
TRIBUTION
DIS
TRIBUTION
H A Z LOC
H A Z LOC
COMPACT NON-FUSED DISCONNECT SWITCHES
B7NFD SERIES
Class I, Div. 1 & 2, Groups B, C, DClass l, Zones 1 & 2, Groups llB+ H2, llAClass II, Div. 1 & 2, Groups E, F, GClass IIINEMA 3, 4, 4X, 7 (B, C, D) 9 (E, F, G)
C e r t i fi e d - F i l e L R 117 14
B7NFD1 B7NFD2
Applications
The PRISM® B7 Series of non-fused disconnect switches are used: • In locations made hazardous due to the
presence of flammable gasses or vapors or ignitable dusts, fibers and flyings.
• Outdoors or indoors in damp, wet and dirty locations, or in areas where frequent washdowns, heavy rain or water spray routinely occurs.
• Use as motor circuit disconnect.
PRISM® enclosures universal design accomodates the following manufacturers switches as standard:• Advance Controls 14046 Series• Allen-Bradley 194E Series (B7NFD1 only)• ABB OT Series• Cutler-Hammer C362N Series• Sprecher + Schuh LA7 Series• Ferraz Shawmut LBS Series
Advance Controls © Advance Controls Inc.Allen-Bradley © Rockwell AutomationABB © Tne ABB GroupCutler-Hammer © Eaton CorporationSprecher + Schuh © Sprecher + Schuh
Features
• Compact size enclosures provide application flexibility with cost savings over industry standard sizes
• Fewer cover bolts reduces installation and maintenance time
• Gasketed flange with O-ring located in side bolt circle to seal out moisture
• Rotary handle style operating mechanism with lockout provision as standard
• Removable ductile mounting lugs adjust to irregular mounting surfaces
• Bodies have top and bottom drilled and tapped conduit entrances for power connection, with custom openings available
• ABB UL98 certified switch supplied for 30-100 Amp units
ADAPTER KIT
• Required for Allen-Bradley and Sprecher + Schuh disconnects Order separately B7KIT - NRW
Standard Materials /Finish
• Enclosures: Copper-free aluminum (less than 4/10 of 1% copper content)
• Cover Bolts: 316 Stainless Steel• O-ring Gasket: Silicone• Finish: Grey Powder Polyester painted
exterior, electrostatically applied.• Electrical rating: 600VAC, 30 - 100 Amp
FEATURES-SPECIFICATIONS
MODIFICATIONSSUFFIX
NUMBER DESCRIPTION
KIT-251 100 amp ground lugSU-2 SU-2 Hinge-9 InstalledSU3* Drain & Breather installed (NEMA 7CD)
SU3B* Drain & Breather installed (NEMA 7BCD)SU9 Special paint finish
A 1 NC+1NO AuxiliaryB7SPNPT Change std. conduit size and location
SU14 Fungus proofing of enclosures * NOTE: The installation of a Drain & Breather will
void the NEMA 4-4X ratings of enclosure.
CATALOG NUMBER SWITCH SINGLE PHASE HP THREE PHASE HP DC HPWIRE SIZE** CONDUIT
SIZESENCLOSURE ONLY W/ABB AMPS / PHASE 120VAC 230VAC 208VAC 230VAC 480VAC 600VAC 230VDCB7NFD1 B7NFD13A 30 / 3P 2 5 10 10 20 30 1 #14-10 1 NPTB7NFD2 B7NFD26A 60 / 3P 3 7.5 20 20 40 40 10 #14-4 1-1/2 NPTB7NFD2 B7NFD21A 100 / 3P 5 15 25 30 50 50 20 #8-1 1-1/2 NPT
** Use MN. 75°C wire
DIMENSIONS
ENCLOSUREOUTSIDE BOX DIMENSIONS NOMINAL INSIDE BOX MOUNTING DIMENSIONS
A B C D E F G H I J KB7NFD1 5-3/4 8-1/16 6-5/16 3-5/8 5-13/16 5-1/16 3-1/8 8-1/8 - - 1-1/4B7NFD2 8-1/8 13-1/16 7-13/16 4-1/4 9-3/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16
Fixed Lug Position For B7NFD1Optional Position For B7NFD2
Standard Lug Position For B7NFD2
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
KDB/KB SERIES
DRAINS / BREATHERS / FLAME ARRESTORS
KDB-1 KB1B KB1DI E C E x C S A 10 . 0 0 0 7 US I R A 10 AT E X13 51U
Class I, Div. 1 & 2, Groups B, C, D Class I, Zones 1 & 2, Groups IIB + H2Class II, Div. 1 & 2, Groups E, F, GClass III, NEMA Type 3II 2 G Ex d IIB IIC T226C Gb IP44Ta = -50°C to +60°C
ApplicationsWhen installed in the top of an enclosure, these fittings act as breathers which allows air flow through the enclosure. Bottom installations permit water from condensation
KB/KD SERIES DRAIN & BREATHERSto drain from the enclosure continuously. The drains and breathers are offered in a variety of hub sizes, 1/4, 3/8 & 1/2 inch NPT and metric M16 & M20.
Body MaterialAluminum with optional stainless steel or brass available for special orders.VolumeFor use in enclosures with a maximum internal volume to 9526 cubic inches or 160 liters.
CATALOG NUMBER THREAD SIZE BODY MATERIAL THIRD PARTY SUITABILITY USA THIRD
PARTY SUITABILITY CANADA THIRD PARTY
SUITABILITY ATEX/IEC Ex
KB1B BREATHERKB1D DRAINKB1BCEN BREATHERKB1DCEN DRAINKBM20BCEN BREATHERKBM20DCEN DRAIN
1/2 NPT1/2 NPT1/2 NPT1/2 NPT
M20M20
ALUMINUMALUMINUMALUMINUMALUMINUMALUMINUMALUMINUM
UL, FM & CSAusUL, FM & CSAus
CSAusCSAusCSAusCSAus
CLASS I GROUPS B, C & DCLASS I, ZONES 1 & 2 GR IIB+H2
CLASS II GROUPS E, F, & GCLASS III ENCL TYPE 3
c CSAc CSAc CSAc CSAc CSAc CSA
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III ENCL TYPE 3SIRA/CSASIRA/CSASIRA/CSASIRA/CSA
II2 G Ex d IICT226C Gb IP44
KDB-1 DRAIN / BREATHERKDB-250 DRAIN / BREATHERKDB-375 DRAIN / BREATHERKDB-250CEN DRAIN / BREATHERKDB-375CEN DRAIN / BREATHERKDB-M16CEN DRAIN / BREATHER
1/2 NPT1/4 NPT3/8 NPT1/4 NPT
38/8 NPTM16
STAINLESS STEELALUMINUMALUMINUMALUMINUMALUMINUMALUMINUM
UL, FM & CSAusCSAusCSAusCSAusCSAusCSAus
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III ENCL TYPE 3
c CSAc CSAc CSAc CSAc CSAc CSA
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III ENCL TYPE 3 SIRA/CSASIRA/CSASIRA/CSA
II 2 G Ex d IIBT3 Gb IP44
See chart below for suitability
Warning – not for use in acetylene atmosphere
ATEX/IEC Ex Certified
KB SERIES FLAME ARRESTOR
I E C E x C S A 10 . 0 0 0 7 US I R A 10 AT E X13 51U See chart below for suitability Warning – not for use in acetylene atmospheres
ATEX/IEC Ex Certified Class I, Div. 1 & 2, Groups B, C, D Class I, Zones 1 & 2, Groups IIB + H2Class II, Div. 1 & 2, Groups E, F, GClass III, NEMA Type 3, 4II 2 G Ex d IIB IICk T3 Gb IP66Ta = -50°C to + 60°C
Applications
The flame arrestor provides a means to connect gas analysis equipment and electro pneumatic devices’ pipe or tubing system through the wall of an explosion-proof enclosure.
Body Material: 6061-T6 series aluminum provided as standard. Optional stainless steel or brass for special orders.
C e r t i fi e d - F i l e L R 117 16
CATALOG NUMBER EXTERNAL THREAD SIZE
INTERNAL THREAD SIZE THIRD PARTY SUITABILITY USA THIRD
PARTY SUITABILITY CANADA THIRD PARTY
SUITABILITY ATEX/IEC Ex
KB1FA25 1/2 NPT 1/4 NPT CSAus CLASS I GROUPS B, C & DCLASS I, ZONES 1 & 2 GR IIB+H2
CLASS II GROUPS E, F, & GCLASS III TYPE 3 & 4
c CSAc CSA
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III TYPE 3 & 4
SIRA/CSA II2 G Ex d IICT3 Gb IP66
KDB-1 DRAIN / BREATHERKDB-250 DRAIN / BREATHERKDB-375 DRAIN / BREATHER
1/2 NPTM20M20
M161/4 NPT
M16
CSAusCSAusCSAus
CLASS I GROUPS B, C & DCLASS I ZONES 1 & 2 GR IIB+H2
CLASS II GROUPS E, F & GCLASS III TYPE 3
c CSAc CSAc CSA
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III TYPE 3
SIRA/CSASIRA/CSASIRA/CSA
II 2 G Ex d IICT3 Gb IP65
TYPICAL INSTALLATION
Air flow = 83 + 15 / -25 SCFH at 5PSI Pressure drop = 1.3 PSI at 100 PSI Maximum flow pressure = 800 PSI Volume = For use in enclosures with a maximum internal volume of 9526 cubic inches or 160 liters.
7/8”
2.96”
C e r t i fi e d - F i l e L R 117 16
C e r t i fi e d F i l e 2 5 2 15
L i s t e d - F i l e E10 514
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KB1FA25SS6
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
EY SERIES
SEALING FITTINGS
Class I, Div. 1 & 2, Groups A, B, C, DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
Consideration for selection seals:
Select the proper sealing fitting for the hazardous gas/vapor involved; i.e., Class I Groups A, B, C, or D. Zone 1, Groups IIC, IIB, IIC.
Select a sealing fitting for the proper use in respect to mounting position. This is particularly critical when the conduit runs between hazardous and nonhazardous areas. Some seals are designed to be mounted in any position; others are restricted to vertical mounting.
Drains
Where there is a probability that liquid or other condensed vapor may be trapped within enclosures for control equipment or at any point in the raceway system, approved means – such as installation of drain seals – shall be provided to prevent moisture accumulation.
For more complete data or special applications, consult the code or your local inspector.
Sealing compounds shall be approved for the purpose and shall not be affected by the surrounding atmosphere or liquids, and shall not have a melting point of less than 93°C. (200°F.).
In the complete seal, the minimum thickness of the sealing compound shall not be less than the trade size of the conduit, and in no case less than 5/8 inch.
Note: The amount of Killark sealing compound and
volume hub size and mounting position of the seal. Refer to installation data table on page F50 for
Schematic drawings illustrate the
dams, and installed seal with drain.
Splices and taps shall not be made in fittings intended only for sealing with compound, nor shall other fittings in which splices or taps are made be filled with compound.
Killark sealing fittings are produced with utmost care to insure a substantial margin of safety. Threads are clean, deep, and snug. When properly installed with Killark sealing compound (SC Type) and Killark non-asbestos fiber (PF Type) for the dams, you can be sure your installation will provide more than adequate safety.
EY EY with Nipple(For Vertical Conduit)
EYD EYD with Nipple(Drain/Seal for Vertical Conduit)
EYS EYS with Nipple(For Vertical or Horizontal Conduit)
ENY ENY with Nipple(For Vertical or Horizontal Conduit)
ENY-2(Fixture Hanger) (See Page L146)
Application & Installation Class I, Divisions 1 and 2
The purpose of seals in a Class I hazardous location is to minimize the passage of gases and vapors and prevent the passage of flames from one electrical installation to another through the conduit system. Seals are required to be installed within 18 inches on any conduit run entering an enclosure which contains devices that may produce arcs, sparks, or high temperature. Where two enclosures are connected by a run of conduit not over 3 ft. long, a single seal located at the center of the run is considered satisfactory. Only explosionproof unions, couplings, elbows, and conduit bodies similar to “L”, “T”, and “X” type shall be permitted between the sealing fitting and the enclosure.
Seals shall be located within 18 inches of the enclosure or fitting on each conduit run of 2 inch size or larger entering an enclosure or fitting that contains terminals, splices, or taps.
Each run of conduit from a hazardous location to a nonhazardous location should be sealed to minimize the amount of gases and vapors communicated beyond the seal.
Class II, Divisions 1 and 2
Where a raceway provides communication between an enclosure which is required to be dust-ignitionproof and one which is not, suitable means shall be provided to prevent the entrance of dust into the dust-ignitionproof enclosure through the raceway.
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS SERIES
SEALING FITTINGS
ENY-3 ENY-3-T with Nipple(For Vertical or Horizontal Conduit) (For Vertical or Horizontal Conduit)
EYS-3 EYS-3-T with Nipple
ENY-1, 2, 3, 4, 5, 6Class I, Div. 1 & 2, Groups A, B, C, DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IIIEYS SeriesClass I, Div. 1 & 2, Groups C, DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
ENY Series EYS Series
Dimensions
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electrostatically applied powder coating
FEATURES-SPECIFICATIONS
EYS SEALING FITTINGS EYS WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” EYS-1 — 2-15/16”(75) 1-13/16”(46) 1-3/16”(30) EYS-1-T —3/4” EYS-2 — 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) EYS-2-T —1” EYS-3 — 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) EYS-3-T —
1-1/4” EYS-4 — 5-3/8”(137) 3”(76) 1-25/32”(45) EYS-4-T —1-1/2” EYS-5 — 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) EYS-5-T —
2” EYS-6 — 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) EYS-6-T —2-1/2” EYS-7 EYS-7M 7-5/8”(194) 4-1/2”(114) 4-1/8”(105) EYS-7-T EYS-7TM
3” EYS-8 EYS-8M 7-5/8”(194) 4-1/2”(114) 4-3/8”(111) EYS-8-T EYS-8TM3-1/2” EYS-9 EYS-9M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-9-T EYS-9TM
4” EYS-0 EYS-0M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-0-T EYS-0TM
ENY SEALING FITTINGS ENY WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” ENY-1 ENY-1M 3-15/16”(100) 1-13/16”(46) 1-3/16”(30) ENY-1-T ENY-1TM3/4” ENY-2 ENY-2M 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) ENY-2-T ENY-2TM1” ENY-3 ENY-3M 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) ENY-3-T ENY-3TM
1-1/4” ENY-4 ENY-4M 5-3/8”(137) 3”(76) 1-25/32”(45) ENY-4-T ENY-4TM1-1/2” ENY-5 ENY-5M 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) ENY-5-T ENY-5TM
2” ENY-6 ENY-6M 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) ENY-6-T ENY-6TM
L i s t e d F i l e N o . E10 514C e r t i fi e d F i l e N o . L R 117 16
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS/EY/EYD SERIES
SEALING MATERIALS
Sealing Compound Packing Fiber Thread Lubricants
Series SC/PF/LUBG
Sealing Materials
SC Series Sealing compound is a cement used extensively for sealing conduit to prevent the spread of explosive gases. It is non-shrinking and a secure seal is formed. SC Series resists acids, water, oil, etc. It is UL Listed for use with Killark ENY, EY, and EYS Series. Also CSA certified for use with any CSA certified sealing fitting.
Packing Fiber
Killark’s Packing Fiber is made from an environmentally safe, non-asbestos material. It is easy to use and forms a positive dam to hold compound (Killark SC Type) in ENY, EY, and EYS Series fittings.
Threaded Lubricants
Two special blends of lubricants have been developed by Killark for use with threaded joints. These lubricants are to be used to prevent galling of pipe threads when threaded into a coupling, junction box, etc. They insure a quick release of undamaged male and female threads when parts are disassembled.
LUBG is a general purpose lubricant to be used in temperatures ranging from 0° to 125°F.
LUBT is a high-quality lubricant to be used in temperatures ranging from -40° to +500°F. It is recommended to be used on hazardous location lighting fixtures.
ENY/EYS suitable for both horizontal or vertical applications.
FEATURES-SPECIFICATIONS
THREAD LUBRICANTSCATALOG NUMBER CONTAINER PACKAGE
LUBT-2 2 oz.LUBG-6 6 oz.
PACKING FIBERCATALOG NUMBER SIZE PACKAGE
PF-2 2 oz.PF-4 4 oz.PF-16 1 lb.
SEALING COMPOUNDCATALOG NUMBER SIZE PACKAGE
SC-4 OZ 4 oz.SC-8 OZ 8 oz.SC-1 LB 1 lb.SC-5 LB 5 lbs.
OUNCES REQUIRED PER FITTINGSEALING COMPOUND
PACKING FIBERHUB SIZE ENY EYS EY/EYD
1/2” 1.5 oz. 3.0 oz. 1.0 oz. 1/16 oz.3/4” 2.0 oz. 3.0 oz. 2.0 oz. 1/8 oz.1” 3.0 oz. 8.0 oz. 4.5 oz. 1/4 oz.
1-1/4” 6.5 oz. 8.5 oz. 7.5 oz. 1/2 oz.1 1/2” 8.5 oz. 17.5 oz. 12.0 oz. 1 oz.
2” 15.0 oz. 27.0 oz. 24.0 oz. 2 oz.2-1/2” — 42.0 oz. 44.0 oz. 3 oz.
3” — 47.0 oz. 44.0 oz. 4 oz.3-1/2” — 56.0 oz. 75.0 oz. 6 oz.
4” — 56.0 oz. 75.0 oz. 9 oz.
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
KDB/KB SERIES
DRAINS / BREATHERS / FLAME ARRESTORS
KDB-1 KB1B KB1DI E C E x C S A 10 . 0 0 0 7 US I R A 10 AT E X13 51U
Class I, Div. 1 & 2, Groups B, C, D Class I, Zones 1 & 2, Groups IIB + H2Class II, Div. 1 & 2, Groups E, F, GClass III, NEMA Type 3II 2 G Ex d IIB IIC T226C Gb IP44Ta = -50°C to +60°C
ApplicationsWhen installed in the top of an enclosure, these fittings act as breathers which allows air flow through the enclosure. Bottom installations permit water from condensation
KB/KD SERIES DRAIN & BREATHERSto drain from the enclosure continuously. The drains and breathers are offered in a variety of hub sizes, 1/4, 3/8 & 1/2 inch NPT and metric M16 & M20.
Body MaterialAluminum with optional stainless steel or brass available for special orders.VolumeFor use in enclosures with a maximum internal volume to 9526 cubic inches or 160 liters.
CATALOG NUMBER THREAD SIZE BODY MATERIAL THIRD PARTY SUITABILITY USA THIRD
PARTY SUITABILITY CANADA THIRD PARTY
SUITABILITY ATEX/IEC Ex
KB1B BREATHERKB1D DRAINKB1BCEN BREATHERKB1DCEN DRAINKBM20BCEN BREATHERKBM20DCEN DRAIN
1/2 NPT1/2 NPT1/2 NPT1/2 NPT
M20M20
ALUMINUMALUMINUMALUMINUMALUMINUMALUMINUMALUMINUM
UL, FM & CSAusUL, FM & CSAus
CSAusCSAusCSAusCSAus
CLASS I GROUPS B, C & DCLASS I, ZONES 1 & 2 GR IIB+H2
CLASS II GROUPS E, F, & GCLASS III ENCL TYPE 3
c CSAc CSAc CSAc CSAc CSAc CSA
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III ENCL TYPE 3SIRA/CSASIRA/CSASIRA/CSASIRA/CSA
II2 G Ex d IICT226C Gb IP44
KDB-1 DRAIN / BREATHERKDB-250 DRAIN / BREATHERKDB-375 DRAIN / BREATHERKDB-250CEN DRAIN / BREATHERKDB-375CEN DRAIN / BREATHERKDB-M16CEN DRAIN / BREATHER
1/2 NPT1/4 NPT3/8 NPT1/4 NPT
38/8 NPTM16
STAINLESS STEELALUMINUMALUMINUMALUMINUMALUMINUMALUMINUM
UL, FM & CSAusCSAusCSAusCSAusCSAusCSAus
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III ENCL TYPE 3
c CSAc CSAc CSAc CSAc CSAc CSA
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III ENCL TYPE 3 SIRA/CSASIRA/CSASIRA/CSA
II 2 G Ex d IIBT3 Gb IP44
See chart below for suitability
Warning – not for use in acetylene atmosphere
ATEX/IEC Ex Certified
KB SERIES FLAME ARRESTOR
I E C E x C S A 10 . 0 0 0 7 US I R A 10 AT E X13 51U See chart below for suitability Warning – not for use in acetylene atmospheres
ATEX/IEC Ex Certified Class I, Div. 1 & 2, Groups B, C, D Class I, Zones 1 & 2, Groups IIB + H2Class II, Div. 1 & 2, Groups E, F, GClass III, NEMA Type 3, 4II 2 G Ex d IIB IICk T3 Gb IP66Ta = -50°C to + 60°C
Applications
The flame arrestor provides a means to connect gas analysis equipment and electro pneumatic devices’ pipe or tubing system through the wall of an explosion-proof enclosure.
Body Material: 6061-T6 series aluminum provided as standard. Optional stainless steel or brass for special orders.
C e r t i fi e d - F i l e L R 117 16
CATALOG NUMBER EXTERNAL THREAD SIZE
INTERNAL THREAD SIZE THIRD PARTY SUITABILITY USA THIRD
PARTY SUITABILITY CANADA THIRD PARTY
SUITABILITY ATEX/IEC Ex
KB1FA25 1/2 NPT 1/4 NPT CSAus CLASS I GROUPS B, C & DCLASS I, ZONES 1 & 2 GR IIB+H2
CLASS II GROUPS E, F, & GCLASS III TYPE 3 & 4
c CSAc CSA
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III TYPE 3 & 4
SIRA/CSA II2 G Ex d IICT3 Gb IP66
KDB-1 DRAIN / BREATHERKDB-250 DRAIN / BREATHERKDB-375 DRAIN / BREATHER
1/2 NPTM20M20
M161/4 NPT
M16
CSAusCSAusCSAus
CLASS I GROUPS B, C & DCLASS I ZONES 1 & 2 GR IIB+H2
CLASS II GROUPS E, F & GCLASS III TYPE 3
c CSAc CSAc CSA
CLASS I GROUPS C & DCLASS I, ZONES 1 & 2 GR IIBCLASS II GROUPS E, F & G
CLASS III TYPE 3
SIRA/CSASIRA/CSASIRA/CSA
II 2 G Ex d IICT3 Gb IP65
TYPICAL INSTALLATION
Air flow = 83 + 15 / -25 SCFH at 5PSI Pressure drop = 1.3 PSI at 100 PSI Maximum flow pressure = 800 PSI Volume = For use in enclosures with a maximum internal volume of 9526 cubic inches or 160 liters.
7/8”
2.96”
C e r t i fi e d - F i l e L R 117 16
C e r t i fi e d F i l e 2 5 2 15
L i s t e d - F i l e E10 514
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KB1FA25SS6
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
EY SERIES
SEALING FITTINGS
Class I, Div. 1 & 2, Groups A, B, C, DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
Consideration for selection seals:
Select the proper sealing fitting for the hazardous gas/vapor involved; i.e., Class I Groups A, B, C, or D. Zone 1, Groups IIC, IIB, IIC.
Select a sealing fitting for the proper use in respect to mounting position. This is particularly critical when the conduit runs between hazardous and nonhazardous areas. Some seals are designed to be mounted in any position; others are restricted to vertical mounting.
Drains
Where there is a probability that liquid or other condensed vapor may be trapped within enclosures for control equipment or at any point in the raceway system, approved means – such as installation of drain seals – shall be provided to prevent moisture accumulation.
For more complete data or special applications, consult the code or your local inspector.
Sealing compounds shall be approved for the purpose and shall not be affected by the surrounding atmosphere or liquids, and shall not have a melting point of less than 93°C. (200°F.).
In the complete seal, the minimum thickness of the sealing compound shall not be less than the trade size of the conduit, and in no case less than 5/8 inch.
Note: The amount of Killark sealing compound and
volume hub size and mounting position of the seal. Refer to installation data table on page F50 for
Schematic drawings illustrate the
dams, and installed seal with drain.
Splices and taps shall not be made in fittings intended only for sealing with compound, nor shall other fittings in which splices or taps are made be filled with compound.
Killark sealing fittings are produced with utmost care to insure a substantial margin of safety. Threads are clean, deep, and snug. When properly installed with Killark sealing compound (SC Type) and Killark non-asbestos fiber (PF Type) for the dams, you can be sure your installation will provide more than adequate safety.
EY EY with Nipple(For Vertical Conduit)
EYD EYD with Nipple(Drain/Seal for Vertical Conduit)
EYS EYS with Nipple(For Vertical or Horizontal Conduit)
ENY ENY with Nipple(For Vertical or Horizontal Conduit)
ENY-2(Fixture Hanger) (See Page L146)
Application & Installation Class I, Divisions 1 and 2
The purpose of seals in a Class I hazardous location is to minimize the passage of gases and vapors and prevent the passage of flames from one electrical installation to another through the conduit system. Seals are required to be installed within 18 inches on any conduit run entering an enclosure which contains devices that may produce arcs, sparks, or high temperature. Where two enclosures are connected by a run of conduit not over 3 ft. long, a single seal located at the center of the run is considered satisfactory. Only explosionproof unions, couplings, elbows, and conduit bodies similar to “L”, “T”, and “X” type shall be permitted between the sealing fitting and the enclosure.
Seals shall be located within 18 inches of the enclosure or fitting on each conduit run of 2 inch size or larger entering an enclosure or fitting that contains terminals, splices, or taps.
Each run of conduit from a hazardous location to a nonhazardous location should be sealed to minimize the amount of gases and vapors communicated beyond the seal.
Class II, Divisions 1 and 2
Where a raceway provides communication between an enclosure which is required to be dust-ignitionproof and one which is not, suitable means shall be provided to prevent the entrance of dust into the dust-ignitionproof enclosure through the raceway.
FEATURES-SPECIFICATIONS
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS SERIES
SEALING FITTINGS
ENY-3 ENY-3-T with Nipple(For Vertical or Horizontal Conduit) (For Vertical or Horizontal Conduit)
EYS-3 EYS-3-T with Nipple
ENY-1, 2, 3, 4, 5, 6Class I, Div. 1 & 2, Groups A, B, C, DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IIIEYS SeriesClass I, Div. 1 & 2, Groups C, DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
ENY Series EYS Series
Dimensions
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electrostatically applied powder coating
FEATURES-SPECIFICATIONS
EYS SEALING FITTINGS EYS WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” EYS-1 — 2-15/16”(75) 1-13/16”(46) 1-3/16”(30) EYS-1-T —3/4” EYS-2 — 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) EYS-2-T —1” EYS-3 — 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) EYS-3-T —
1-1/4” EYS-4 — 5-3/8”(137) 3”(76) 1-25/32”(45) EYS-4-T —1-1/2” EYS-5 — 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) EYS-5-T —
2” EYS-6 — 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) EYS-6-T —2-1/2” EYS-7 EYS-7M 7-5/8”(194) 4-1/2”(114) 4-1/8”(105) EYS-7-T EYS-7TM
3” EYS-8 EYS-8M 7-5/8”(194) 4-1/2”(114) 4-3/8”(111) EYS-8-T EYS-8TM3-1/2” EYS-9 EYS-9M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-9-T EYS-9TM
4” EYS-0 EYS-0M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-0-T EYS-0TM
ENY SEALING FITTINGS ENY WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” ENY-1 ENY-1M 3-15/16”(100) 1-13/16”(46) 1-3/16”(30) ENY-1-T ENY-1TM3/4” ENY-2 ENY-2M 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) ENY-2-T ENY-2TM1” ENY-3 ENY-3M 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) ENY-3-T ENY-3TM
1-1/4” ENY-4 ENY-4M 5-3/8”(137) 3”(76) 1-25/32”(45) ENY-4-T ENY-4TM1-1/2” ENY-5 ENY-5M 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) ENY-5-T ENY-5TM
2” ENY-6 ENY-6M 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) ENY-6-T ENY-6TM
L i s t e d F i l e N o . E10 514C e r t i fi e d F i l e N o . L R 117 16
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS/EY/EYD SERIES
SEALING MATERIALS
Sealing Compound Packing Fiber Thread Lubricants
Series SC/PF/LUBG
Sealing Materials
SC Series Sealing compound is a cement used extensively for sealing conduit to prevent the spread of explosive gases. It is non-shrinking and a secure seal is formed. SC Series resists acids, water, oil, etc. It is UL Listed for use with Killark ENY, EY, and EYS Series. Also CSA certified for use with any CSA certified sealing fitting.
Packing Fiber
Killark’s Packing Fiber is made from an environmentally safe, non-asbestos material. It is easy to use and forms a positive dam to hold compound (Killark SC Type) in ENY, EY, and EYS Series fittings.
Threaded Lubricants
Two special blends of lubricants have been developed by Killark for use with threaded joints. These lubricants are to be used to prevent galling of pipe threads when threaded into a coupling, junction box, etc. They insure a quick release of undamaged male and female threads when parts are disassembled.
LUBG is a general purpose lubricant to be used in temperatures ranging from 0° to 125°F.
LUBT is a high-quality lubricant to be used in temperatures ranging from -40° to +500°F. It is recommended to be used on hazardous location lighting fixtures.
ENY/EYS suitable for both horizontal or vertical applications.
FEATURES-SPECIFICATIONS
THREAD LUBRICANTSCATALOG NUMBER CONTAINER PACKAGE
LUBT-2 2 oz.LUBG-6 6 oz.
PACKING FIBERCATALOG NUMBER SIZE PACKAGE
PF-2 2 oz.PF-4 4 oz.PF-16 1 lb.
SEALING COMPOUNDCATALOG NUMBER SIZE PACKAGE
SC-4 OZ 4 oz.SC-8 OZ 8 oz.SC-1 LB 1 lb.SC-5 LB 5 lbs.
OUNCES REQUIRED PER FITTINGSEALING COMPOUND
PACKING FIBERHUB SIZE ENY EYS EY/EYD
1/2” 1.5 oz. 3.0 oz. 1.0 oz. 1/16 oz.3/4” 2.0 oz. 3.0 oz. 2.0 oz. 1/8 oz.1” 3.0 oz. 8.0 oz. 4.5 oz. 1/4 oz.
1-1/4” 6.5 oz. 8.5 oz. 7.5 oz. 1/2 oz.1 1/2” 8.5 oz. 17.5 oz. 12.0 oz. 1 oz.
2” 15.0 oz. 27.0 oz. 24.0 oz. 2 oz.2-1/2” — 42.0 oz. 44.0 oz. 3 oz.
3” — 47.0 oz. 44.0 oz. 4 oz.3-1/2” — 56.0 oz. 75.0 oz. 6 oz.
4” — 56.0 oz. 75.0 oz. 9 oz.
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS SERIES
SEALING FITTINGS
ENY-3 ENY-3-T with Nipple(For Vertical or Horizontal Conduit) (For Vertical or Horizontal Conduit)
EYS-3 EYS-3-T with Nipple
ENY-1, 2, 3, 4, 5, 6Class I, Div. 1 & 2, Groups A, B, C, DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IIIEYS SeriesClass I, Div. 1 & 2, Groups C, DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
ENY Series EYS Series
Dimensions
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electrostatically applied powder coating
FEATURES-SPECIFICATIONS
EYS SEALING FITTINGS EYS WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” EYS-1 — 2-15/16”(75) 1-13/16”(46) 1-3/16”(30) EYS-1-T —3/4” EYS-2 — 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) EYS-2-T —1” EYS-3 — 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) EYS-3-T —
1-1/4” EYS-4 — 5-3/8”(137) 3”(76) 1-25/32”(45) EYS-4-T —1-1/2” EYS-5 — 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) EYS-5-T —
2” EYS-6 — 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) EYS-6-T —2-1/2” EYS-7 EYS-7M 7-5/8”(194) 4-1/2”(114) 4-1/8”(105) EYS-7-T EYS-7TM
3” EYS-8 EYS-8M 7-5/8”(194) 4-1/2”(114) 4-3/8”(111) EYS-8-T EYS-8TM3-1/2” EYS-9 EYS-9M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-9-T EYS-9TM
4” EYS-0 EYS-0M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-0-T EYS-0TM
ENY SEALING FITTINGS ENY WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” ENY-1 ENY-1M 3-15/16”(100) 1-13/16”(46) 1-3/16”(30) ENY-1-T ENY-1TM3/4” ENY-2 ENY-2M 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) ENY-2-T ENY-2TM1” ENY-3 ENY-3M 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) ENY-3-T ENY-3TM
1-1/4” ENY-4 ENY-4M 5-3/8”(137) 3”(76) 1-25/32”(45) ENY-4-T ENY-4TM1-1/2” ENY-5 ENY-5M 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) ENY-5-T ENY-5TM
2” ENY-6 ENY-6M 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) ENY-6-T ENY-6TM
L i s t e d F i l e N o . E10 514C e r t i fi e d F i l e N o . L R 117 16
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS/EY/EYD SERIES
SEALING MATERIALS
Sealing Compound Packing Fiber Thread Lubricants
Series SC/PF/LUBG
Sealing Materials
SC Series Sealing compound is a cement used extensively for sealing conduit to prevent the spread of explosive gases. It is non-shrinking and a secure seal is formed. SC Series resists acids, water, oil, etc. It is UL Listed for use with Killark ENY, EY, and EYS Series. Also CSA certified for use with any CSA certified sealing fitting.
Packing Fiber
Killark’s Packing Fiber is made from an environmentally safe, non-asbestos material. It is easy to use and forms a positive dam to hold compound (Killark SC Type) in ENY, EY, and EYS Series fittings.
Threaded Lubricants
Two special blends of lubricants have been developed by Killark for use with threaded joints. These lubricants are to be used to prevent galling of pipe threads when threaded into a coupling, junction box, etc. They insure a quick release of undamaged male and female threads when parts are disassembled.
LUBG is a general purpose lubricant to be used in temperatures ranging from 0° to 125°F.
LUBT is a high-quality lubricant to be used in temperatures ranging from -40° to +500°F. It is recommended to be used on hazardous location lighting fixtures.
ENY/EYS suitable for both horizontal or vertical applications.
FEATURES-SPECIFICATIONS
THREAD LUBRICANTSCATALOG NUMBER CONTAINER PACKAGE
LUBT-2 2 oz.LUBG-6 6 oz.
PACKING FIBERCATALOG NUMBER SIZE PACKAGE
PF-2 2 oz.PF-4 4 oz.PF-16 1 lb.
SEALING COMPOUNDCATALOG NUMBER SIZE PACKAGE
SC-4 OZ 4 oz.SC-8 OZ 8 oz.SC-1 LB 1 lb.SC-5 LB 5 lbs.
OUNCES REQUIRED PER FITTINGSEALING COMPOUND
PACKING FIBERHUB SIZE ENY EYS EY/EYD
1/2” 1.5 oz. 3.0 oz. 1.0 oz. 1/16 oz.3/4” 2.0 oz. 3.0 oz. 2.0 oz. 1/8 oz.1” 3.0 oz. 8.0 oz. 4.5 oz. 1/4 oz.
1-1/4” 6.5 oz. 8.5 oz. 7.5 oz. 1/2 oz.1 1/2” 8.5 oz. 17.5 oz. 12.0 oz. 1 oz.
2” 15.0 oz. 27.0 oz. 24.0 oz. 2 oz.2-1/2” — 42.0 oz. 44.0 oz. 3 oz.
3” — 47.0 oz. 44.0 oz. 4 oz.3-1/2” — 56.0 oz. 75.0 oz. 6 oz.
4” — 56.0 oz. 75.0 oz. 9 oz.
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS SERIES
SEALING FITTINGS
ENY-3 ENY-3-T with Nipple(For Vertical or Horizontal Conduit) (For Vertical or Horizontal Conduit)
EYS-3 EYS-3-T with Nipple
ENY-1, 2, 3, 4, 5, 6Class I, Div. 1 & 2, Groups A, B, C, DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IIIEYS SeriesClass I, Div. 1 & 2, Groups C, DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
ENY Series EYS Series
Dimensions
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electrostatically applied powder coating
FEATURES-SPECIFICATIONS
EYS SEALING FITTINGS EYS WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” EYS-1 — 2-15/16”(75) 1-13/16”(46) 1-3/16”(30) EYS-1-T —3/4” EYS-2 — 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) EYS-2-T —1” EYS-3 — 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) EYS-3-T —
1-1/4” EYS-4 — 5-3/8”(137) 3”(76) 1-25/32”(45) EYS-4-T —1-1/2” EYS-5 — 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) EYS-5-T —
2” EYS-6 — 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) EYS-6-T —2-1/2” EYS-7 EYS-7M 7-5/8”(194) 4-1/2”(114) 4-1/8”(105) EYS-7-T EYS-7TM
3” EYS-8 EYS-8M 7-5/8”(194) 4-1/2”(114) 4-3/8”(111) EYS-8-T EYS-8TM3-1/2” EYS-9 EYS-9M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-9-T EYS-9TM
4” EYS-0 EYS-0M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-0-T EYS-0TM
ENY SEALING FITTINGS ENY WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” ENY-1 ENY-1M 3-15/16”(100) 1-13/16”(46) 1-3/16”(30) ENY-1-T ENY-1TM3/4” ENY-2 ENY-2M 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) ENY-2-T ENY-2TM1” ENY-3 ENY-3M 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) ENY-3-T ENY-3TM
1-1/4” ENY-4 ENY-4M 5-3/8”(137) 3”(76) 1-25/32”(45) ENY-4-T ENY-4TM1-1/2” ENY-5 ENY-5M 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) ENY-5-T ENY-5TM
2” ENY-6 ENY-6M 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) ENY-6-T ENY-6TM
L i s t e d F i l e N o . E10 514C e r t i fi e d F i l e N o . L R 117 16
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS/EY/EYD SERIES
SEALING MATERIALS
Sealing Compound Packing Fiber Thread Lubricants
Series SC/PF/LUBG
Sealing Materials
SC Series Sealing compound is a cement used extensively for sealing conduit to prevent the spread of explosive gases. It is non-shrinking and a secure seal is formed. SC Series resists acids, water, oil, etc. It is UL Listed for use with Killark ENY, EY, and EYS Series. Also CSA certified for use with any CSA certified sealing fitting.
Packing Fiber
Killark’s Packing Fiber is made from an environmentally safe, non-asbestos material. It is easy to use and forms a positive dam to hold compound (Killark SC Type) in ENY, EY, and EYS Series fittings.
Threaded Lubricants
Two special blends of lubricants have been developed by Killark for use with threaded joints. These lubricants are to be used to prevent galling of pipe threads when threaded into a coupling, junction box, etc. They insure a quick release of undamaged male and female threads when parts are disassembled.
LUBG is a general purpose lubricant to be used in temperatures ranging from 0° to 125°F.
LUBT is a high-quality lubricant to be used in temperatures ranging from -40° to +500°F. It is recommended to be used on hazardous location lighting fixtures.
ENY/EYS suitable for both horizontal or vertical applications.
FEATURES-SPECIFICATIONS
THREAD LUBRICANTSCATALOG NUMBER CONTAINER PACKAGE
LUBT-2 2 oz.LUBG-6 6 oz.
PACKING FIBERCATALOG NUMBER SIZE PACKAGE
PF-2 2 oz.PF-4 4 oz.PF-16 1 lb.
SEALING COMPOUNDCATALOG NUMBER SIZE PACKAGE
SC-4 OZ 4 oz.SC-8 OZ 8 oz.SC-1 LB 1 lb.SC-5 LB 5 lbs.
OUNCES REQUIRED PER FITTINGSEALING COMPOUND
PACKING FIBERHUB SIZE ENY EYS EY/EYD
1/2” 1.5 oz. 3.0 oz. 1.0 oz. 1/16 oz.3/4” 2.0 oz. 3.0 oz. 2.0 oz. 1/8 oz.1” 3.0 oz. 8.0 oz. 4.5 oz. 1/4 oz.
1-1/4” 6.5 oz. 8.5 oz. 7.5 oz. 1/2 oz.1 1/2” 8.5 oz. 17.5 oz. 12.0 oz. 1 oz.
2” 15.0 oz. 27.0 oz. 24.0 oz. 2 oz.2-1/2” — 42.0 oz. 44.0 oz. 3 oz.
3” — 47.0 oz. 44.0 oz. 4 oz.3-1/2” — 56.0 oz. 75.0 oz. 6 oz.
4” — 56.0 oz. 75.0 oz. 9 oz.
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS SERIES
SEALING FITTINGS
ENY-3 ENY-3-T with Nipple(For Vertical or Horizontal Conduit) (For Vertical or Horizontal Conduit)
EYS-3 EYS-3-T with Nipple
ENY-1, 2, 3, 4, 5, 6Class I, Div. 1 & 2, Groups A, B, C, DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IIIEYS SeriesClass I, Div. 1 & 2, Groups C, DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
ENY Series EYS Series
Dimensions
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electrostatically applied powder coating
FEATURES-SPECIFICATIONS
EYS SEALING FITTINGS EYS WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” EYS-1 — 2-15/16”(75) 1-13/16”(46) 1-3/16”(30) EYS-1-T —3/4” EYS-2 — 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) EYS-2-T —1” EYS-3 — 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) EYS-3-T —
1-1/4” EYS-4 — 5-3/8”(137) 3”(76) 1-25/32”(45) EYS-4-T —1-1/2” EYS-5 — 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) EYS-5-T —
2” EYS-6 — 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) EYS-6-T —2-1/2” EYS-7 EYS-7M 7-5/8”(194) 4-1/2”(114) 4-1/8”(105) EYS-7-T EYS-7TM
3” EYS-8 EYS-8M 7-5/8”(194) 4-1/2”(114) 4-3/8”(111) EYS-8-T EYS-8TM3-1/2” EYS-9 EYS-9M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-9-T EYS-9TM
4” EYS-0 EYS-0M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-0-T EYS-0TM
ENY SEALING FITTINGS ENY WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” ENY-1 ENY-1M 3-15/16”(100) 1-13/16”(46) 1-3/16”(30) ENY-1-T ENY-1TM3/4” ENY-2 ENY-2M 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) ENY-2-T ENY-2TM1” ENY-3 ENY-3M 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) ENY-3-T ENY-3TM
1-1/4” ENY-4 ENY-4M 5-3/8”(137) 3”(76) 1-25/32”(45) ENY-4-T ENY-4TM1-1/2” ENY-5 ENY-5M 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) ENY-5-T ENY-5TM
2” ENY-6 ENY-6M 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) ENY-6-T ENY-6TM
L i s t e d F i l e N o . E10 514C e r t i fi e d F i l e N o . L R 117 16
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS/EY/EYD SERIES
SEALING MATERIALS
Sealing Compound Packing Fiber Thread Lubricants
Series SC/PF/LUBG
Sealing Materials
SC Series Sealing compound is a cement used extensively for sealing conduit to prevent the spread of explosive gases. It is non-shrinking and a secure seal is formed. SC Series resists acids, water, oil, etc. It is UL Listed for use with Killark ENY, EY, and EYS Series. Also CSA certified for use with any CSA certified sealing fitting.
Packing Fiber
Killark’s Packing Fiber is made from an environmentally safe, non-asbestos material. It is easy to use and forms a positive dam to hold compound (Killark SC Type) in ENY, EY, and EYS Series fittings.
Threaded Lubricants
Two special blends of lubricants have been developed by Killark for use with threaded joints. These lubricants are to be used to prevent galling of pipe threads when threaded into a coupling, junction box, etc. They insure a quick release of undamaged male and female threads when parts are disassembled.
LUBG is a general purpose lubricant to be used in temperatures ranging from 0° to 125°F.
LUBT is a high-quality lubricant to be used in temperatures ranging from -40° to +500°F. It is recommended to be used on hazardous location lighting fixtures.
ENY/EYS suitable for both horizontal or vertical applications.
FEATURES-SPECIFICATIONS
THREAD LUBRICANTSCATALOG NUMBER CONTAINER PACKAGE
LUBT-2 2 oz.LUBG-6 6 oz.
PACKING FIBERCATALOG NUMBER SIZE PACKAGE
PF-2 2 oz.PF-4 4 oz.PF-16 1 lb.
SEALING COMPOUNDCATALOG NUMBER SIZE PACKAGE
SC-4 OZ 4 oz.SC-8 OZ 8 oz.SC-1 LB 1 lb.SC-5 LB 5 lbs.
OUNCES REQUIRED PER FITTINGSEALING COMPOUND
PACKING FIBERHUB SIZE ENY EYS EY/EYD
1/2” 1.5 oz. 3.0 oz. 1.0 oz. 1/16 oz.3/4” 2.0 oz. 3.0 oz. 2.0 oz. 1/8 oz.1” 3.0 oz. 8.0 oz. 4.5 oz. 1/4 oz.
1-1/4” 6.5 oz. 8.5 oz. 7.5 oz. 1/2 oz.1 1/2” 8.5 oz. 17.5 oz. 12.0 oz. 1 oz.
2” 15.0 oz. 27.0 oz. 24.0 oz. 2 oz.2-1/2” — 42.0 oz. 44.0 oz. 3 oz.
3” — 47.0 oz. 44.0 oz. 4 oz.3-1/2” — 56.0 oz. 75.0 oz. 6 oz.
4” — 56.0 oz. 75.0 oz. 9 oz.
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS SERIES
SEALING FITTINGS
ENY-3 ENY-3-T with Nipple(For Vertical or Horizontal Conduit) (For Vertical or Horizontal Conduit)
EYS-3 EYS-3-T with Nipple
ENY-1, 2, 3, 4, 5, 6Class I, Div. 1 & 2, Groups A, B, C, DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IIIEYS SeriesClass I, Div. 1 & 2, Groups C, DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
ENY Series EYS Series
Dimensions
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electrostatically applied powder coating
FEATURES-SPECIFICATIONS
EYS SEALING FITTINGS EYS WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” EYS-1 — 2-15/16”(75) 1-13/16”(46) 1-3/16”(30) EYS-1-T —3/4” EYS-2 — 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) EYS-2-T —1” EYS-3 — 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) EYS-3-T —
1-1/4” EYS-4 — 5-3/8”(137) 3”(76) 1-25/32”(45) EYS-4-T —1-1/2” EYS-5 — 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) EYS-5-T —
2” EYS-6 — 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) EYS-6-T —2-1/2” EYS-7 EYS-7M 7-5/8”(194) 4-1/2”(114) 4-1/8”(105) EYS-7-T EYS-7TM
3” EYS-8 EYS-8M 7-5/8”(194) 4-1/2”(114) 4-3/8”(111) EYS-8-T EYS-8TM3-1/2” EYS-9 EYS-9M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-9-T EYS-9TM
4” EYS-0 EYS-0M 7-1/8”(181) 5-3/16”(132) 4-3/4”(121) EYS-0-T EYS-0TM
ENY SEALING FITTINGS ENY WITH NIPPLE
HUB SIZECATALOG NUMBER DIMENSIONS
TURNINGRADIUS
CATALOG NUMBERKILLARK
ALUMINUMDURALOY
IRON A B KILLARKALUMINUM
DURALOYIRON
1/2” ENY-1 ENY-1M 3-15/16”(100) 1-13/16”(46) 1-3/16”(30) ENY-1-T ENY-1TM3/4” ENY-2 ENY-2M 4-1/16”(103) 2-1/16”(52) 1-9/32”(33) ENY-2-T ENY-2TM1” ENY-3 ENY-3M 4-25/32”(121) 2-11/32”(60) 1-13/32”(36) ENY-3-T ENY-3TM
1-1/4” ENY-4 ENY-4M 5-3/8”(137) 3”(76) 1-25/32”(45) ENY-4-T ENY-4TM1-1/2” ENY-5 ENY-5M 5-11/16”(144) 3-1/4”(83) 1-29/32”(48) ENY-5-T ENY-5TM
2” ENY-6 ENY-6M 6-3/8”(162) 3-15/16”(100) 2-5/16”(59) ENY-6-T ENY-6TM
L i s t e d F i l e N o . E10 514C e r t i fi e d F i l e N o . L R 117 16
S e e fi l e s f o r d e t a i l s o r c a l l K i l l a r k .
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
ENY/EYS/EY/EYD SERIES
SEALING MATERIALS
Sealing Compound Packing Fiber Thread Lubricants
Series SC/PF/LUBG
Sealing Materials
SC Series Sealing compound is a cement used extensively for sealing conduit to prevent the spread of explosive gases. It is non-shrinking and a secure seal is formed. SC Series resists acids, water, oil, etc. It is UL Listed for use with Killark ENY, EY, and EYS Series. Also CSA certified for use with any CSA certified sealing fitting.
Packing Fiber
Killark’s Packing Fiber is made from an environmentally safe, non-asbestos material. It is easy to use and forms a positive dam to hold compound (Killark SC Type) in ENY, EY, and EYS Series fittings.
Threaded Lubricants
Two special blends of lubricants have been developed by Killark for use with threaded joints. These lubricants are to be used to prevent galling of pipe threads when threaded into a coupling, junction box, etc. They insure a quick release of undamaged male and female threads when parts are disassembled.
LUBG is a general purpose lubricant to be used in temperatures ranging from 0° to 125°F.
LUBT is a high-quality lubricant to be used in temperatures ranging from -40° to +500°F. It is recommended to be used on hazardous location lighting fixtures.
ENY/EYS suitable for both horizontal or vertical applications.
FEATURES-SPECIFICATIONS
THREAD LUBRICANTSCATALOG NUMBER CONTAINER PACKAGE
LUBT-2 2 oz.LUBG-6 6 oz.
PACKING FIBERCATALOG NUMBER SIZE PACKAGE
PF-2 2 oz.PF-4 4 oz.PF-16 1 lb.
SEALING COMPOUNDCATALOG NUMBER SIZE PACKAGE
SC-4 OZ 4 oz.SC-8 OZ 8 oz.SC-1 LB 1 lb.SC-5 LB 5 lbs.
OUNCES REQUIRED PER FITTINGSEALING COMPOUND
PACKING FIBERHUB SIZE ENY EYS EY/EYD
1/2” 1.5 oz. 3.0 oz. 1.0 oz. 1/16 oz.3/4” 2.0 oz. 3.0 oz. 2.0 oz. 1/8 oz.1” 3.0 oz. 8.0 oz. 4.5 oz. 1/4 oz.
1-1/4” 6.5 oz. 8.5 oz. 7.5 oz. 1/2 oz.1 1/2” 8.5 oz. 17.5 oz. 12.0 oz. 1 oz.
2” 15.0 oz. 27.0 oz. 24.0 oz. 2 oz.2-1/2” — 42.0 oz. 44.0 oz. 3 oz.
3” — 47.0 oz. 44.0 oz. 4 oz.3-1/2” — 56.0 oz. 75.0 oz. 6 oz.
4” — 56.0 oz. 75.0 oz. 9 oz.
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
EYD SERIES
DRAIN SEALING FITTING
EYD-75M EYD-75TM
Class I, Div. 1 & 2, Groups B, C, D Class I, Zone 1, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups E, F, G Class III
C e r t i fi e d
Applications
To seal and drain vertical conduits. To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit.
Features
• Threaded for Rigid Conduit or IMC• Tapered threads (NPT)• Simple to install. Internal drainage path
provides a visual means to ensure that the compound chamber is properly filled. No need to use hoses and wires
• Large cover openings for easy packing of fiber dam on 1/2” through 1” sizes
• Temporary plastic sleeve protects thread for drain/breather from contamination when pouring compound
• Unique design enables installation of drain/breather right after compound is poured – no waiting
• Provides continuous water drain path while allowing conduit run to breathe, in compliance with the NEC
• Includes Drain Breather Fitting KDB-375
Material/Finish
Copper-free Aluminum (less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electro-statically applied powder coating
EYD EYD with Nipple
FEATURES-SPECIFICATIONS EYD DRAIN SEALING FITTINGS
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)KILLARK ALUMINUM A B
1/2” EYD-50 3-1/2”(89) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75 3-3/4”(95) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100 4-3/8”(111) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS WITH NIPPLE
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)KILLARK ALUMINUM A B
1/2” EYD-50T 4-3/8”(111) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75T 4-5/8”(118) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100T 5-1/2”(140) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS – IRON
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)DURALOY IRON A B
1/2” EYD-50M 3-1/2”(89) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75M 3-3/4”(95) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100M 4-3/8”(111) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS WITH NIPPLE – IRON
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)DURALOY IRON A B
1/2” EYD-50TM 4-3/8”(111) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75TM 4-5/8”(118) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100TM 5-1/2”(140) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
NEW!DRAIN SEAL
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
EYD SERIES
DRAIN SEALING FITTING
EYD-75M EYD-75TM
Class I, Div. 1 & 2, Groups B, C, D Class I, Zone 1, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups E, F, G Class III
C e r t i fi e d
Applications
To seal and drain vertical conduits. To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit.
Features
• Threaded for Rigid Conduit or IMC• Tapered threads (NPT)• Simple to install. Internal drainage path
provides a visual means to ensure that the compound chamber is properly filled. No need to use hoses and wires
• Large cover openings for easy packing of fiber dam on 1/2” through 1” sizes
• Temporary plastic sleeve protects thread for drain/breather from contamination when pouring compound
• Unique design enables installation of drain/breather right after compound is poured – no waiting
• Provides continuous water drain path while allowing conduit run to breathe, in compliance with the NEC
• Includes Drain Breather Fitting KDB-375
Material/Finish
Copper-free Aluminum (less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electro-statically applied powder coating
EYD EYD with Nipple
FEATURES-SPECIFICATIONS EYD DRAIN SEALING FITTINGS
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)KILLARK ALUMINUM A B
1/2” EYD-50 3-1/2”(89) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75 3-3/4”(95) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100 4-3/8”(111) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS WITH NIPPLE
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)KILLARK ALUMINUM A B
1/2” EYD-50T 4-3/8”(111) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75T 4-5/8”(118) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100T 5-1/2”(140) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS – IRON
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)DURALOY IRON A B
1/2” EYD-50M 3-1/2”(89) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75M 3-3/4”(95) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100M 4-3/8”(111) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS WITH NIPPLE – IRON
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)DURALOY IRON A B
1/2” EYD-50TM 4-3/8”(111) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75TM 4-5/8”(118) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100TM 5-1/2”(140) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
NEW!DRAIN SEAL
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
LZ2NE/LZ2NSE SERIES
EMERGENCY FLUORESCENT
FEATURES-SPECIFICATIONS
Applications
LINEARLITE Emergency Lighting fixtures provide continuous illumination under normal power and switch to emergency battery backup during power outages. Units contain a battery unit that provides the OSHA required 90 minutes of illumination for egress.
Units are available in non-metallic or 316 Stainless construction and designed for wet, harsh and corrosive environments. The LZ2NE and LZ2SE Series can also be used in Class I, Division 2 and Zone 2 hazardous vapors and in Class II areas where combustible dusts may exist. Typical areas used are in refineries, chemical plants, waste water & sewage treatment facilities, as well as in tunnels, food processing and coastal areas.
ABS (American Bureau of Shipping) type approval for use on decks, vessels, platforms, garages, ships and boats. Also suitable for docks and marinas.
Additional DataL191 or L192 - FeaturesL193 - Ballast DataL194 - Mounting AccessoriesL194 - L195 - Photometrics
Features
• NEMA 4 & IP66 rated enclosure• Housing – one piece fiberglass reinforced
polyester or 316 Stainless Steel• Clear Lexan® impact resistant
polycarbonate lens (Lexan is a registered trademark of General Electric)
• Two 3/4” NTP hubs – one at each end (includes one 3/4” close-up plug and two 3/4” X 1/2” reducers for maximum user flexibility
• Two 1/4”- 20 bushings furnished in top of fixture for threaded rod
Digit after E is number of lamps energized during power loss. For optional fused ballasts, add to catalog number F1 for 120V, F4 for 277V, F8 for 230V. Fusing no for marine or Canadian use. Lamps not included.
Magnetic ballast LZ2SE only for Group E LZ2NE is NSF approved
LZ2NE/LZ2SE BATTERY-BACKEDNUMBER OF
LAMPS/WATTSVOLTAGE AC 60 Hz DESCRIPTION LZ2NE LZ2SE
BIAXIAL LAMP TYPE FIXTURES
1-40W 120-277V 2’ 1 - Lamp Biaxial Electronic 50/60 Hz 0°F Start 4-Pin LZ2NE1-40130 LZ2SE1-40130
1-55W 120-277V 2’ 1 - Lamp Biaxial Electronic 50/60 Hz 0°F Start 4-Pin LZ2NE1-55130 LZ2SE1-55130
2-40W 120-277V 2’ 2 - Lamp Biaxial Electronic 50/60 Hz 0°F Start 4-Pin LZ2NE1-40230 LZ2SE1-40230
4-40W 120-277V 4’ 4 - Lamp Biaxial Electronic 50/60 Hz 0°F Start 4-Pin LZ2NE1-40430 LZ2SE1-40430
DOUBLE-ENDED LAMP TYPE FIXTURES
2-17W 120-277V 2’ 2 - Lamp T-8 Electronic 50/60 Hz 0°F Start Medium Bi-Pin LZ2NE2-17230 LZ2SE2-17230
3-17W 120-277V 2’ 3 - Lamp T-8 Electronic 50/60 Hz 0°F Start Medium Bi-Pin LZ2NE2-17330 LZ2SE2-17330
2-28W 120-277V 4’ 2 - Lamp T-5 Electronic 50/60 Hz 0°F Start Miniature Bi-Pin LZ2NE1-28230 LZ2SE1-28230
3-28W 120-277V 4’ 3 - Lamp T-8 Electronic 50/60 Hz 0°F Start Miniature Bi-Pin LZ2NE1-28330 LZ2SE1-28330
2-32W
2-32W
120-277V120-277V
347V
4’ 2 - Lamp T-8 Electronic 50/60 Hz 0°F Start Medium Bi-Pin
LZ2NE1-32230LZ2NE2-32230LZ2NE2-32215
LZ2SE1-32230LZ2SE2-32230LZ2SE2-32215
3-32W
3-32W
120-277V120-277V
347V
4’ 3 - Lamp T-8 Electronic 50/60 Hz 0°F Start Medium Bi-Pin
LZ2NE1-32330LZ2NE2-32330LZ2NE2-32315
LZ2SE1-32330LZ2SE2-32330LZ2SE2-32315
2-40W120V277V
230V 50 Hz
4’ 2-Lamp T-12 Electronic Medium Bi-Pin Start 50°F 40W/60°F 34W
LZ2NE2-40201LZ2NE2-40204LZ2NE2-40208
LZ2SE2-40201LZ2SE2-40204LZ2SE2-40208
2-44W 120-277V 4’ 2-Lamp T-8 Electronic -20°F Start High Output Recessed Double Contact LZ2NE1-44230 LZ2SE1-44230
2-54W 120-277V 4’ 2 - Lamp T-5 Electronic 50/60 Hz -20°F Start Miniature Bi-Pin LZ2NE1-54230 LZ2SE1-54230
2-60W 120-277V 4’ 2-Lamp T-12 Electronic -20°F Start High Output Recessed Double Contact LZ2NE1-60201 LZ2SE1-60230
EMERGENCY LUMEN CHARTLAMPS INITIAL LUMENS
2 X 17 T8 5501 X 40 BIAXIAL 9001 X 55 BIAXIAL 950
1 X 28 T5 11751 X 32 T8 (E1) 9252 X 32 T8 (E2) 625
2 X 40 T12 6101 X 44 T8 9501 X 54 T5 12001 X 60 T12 780
Class I, Div. 2 Groups A, B, C, DClass l, Zones 2, Groups IIC, llB, llAClass II, Div. 1 & 2, Groups E, F, GAEx nAII, Ex nAIIWet LocationsNEMA 4X, IP66
Type ApprovalABSFood HandlingNSF
C e r t i fi e d - F i l e L R 117 13
REPLACEMENT BATTERY UNITKFBP7 KFBP7HO
LZ2NE 2’ Non-metallic
LZ2SE 4’ Stainless
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
NWP SERIES
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES
FEATURES-SPECIFICATIONSApplications
Killark’s NWP Series of fluorescent luminaires are designed for task lighting of wet & corrosive NEMA 4X environments and hazardous locations.
Typical uses include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, agricultural, commercial, industrial, and mining facilities.
NWP surface mount luminaires contain no exposed glass and carry Class II, F&G ratings required for many food proccessing areas.
Features
• Non-metallic housing has a lightweight yet robust low profile construction
• Can be wall mounted or ceiling mounted in horizontal or vertical position
• Energy and labor saving fluorescent• Emergency and normal power models
available.• Emergency version has internal battery
which provides 90 minutes of illumination in the event of a power failure
• Resists corrosive effects of most chemicals, hydrocarbons and solvents
• Designed for indoor and outdoor applications• Includes fluorescent lamp• ‘World Voltage’ ballasts for 120VAC through
277VAC 50/60Hz installations• Wiring terminals are included as standard
Materials
• Enclosure – High strength polycarbonate• Gasket – Silicone• External Hardware – Stainless steel• Lens – Lexan®
• Entry – One ¾” NPT copper-free aluminum hub with ¾ x ½” reducer is standard. A second hub may be purchased separately.
Lexan® is a registered trademark of General Electric
NWP WALLPACK 13-26W FLUORESCENT WLONE 3/4” ALUMINUM HUB
LAMP VOLTAGE DESCRIPTION CAT. NUMBER MAX.AMBIENT SUITIBILITY MIN START
NORMAL POWER MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFN1330A 40°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFN1830A 40°C 15°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFN2630A 40°C 15°C
1-26W 120V DC 26W WALL OR CEILING NWPFN26DC120A 40°C 15°C
NORMAL AND EMERGENCY MODELS1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFE131330A 35°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFE181830A 30°C 15°C
EMERGENCY ONLY MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFEOO1330A 40°C 0°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFEOO1830A 40°C 0°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFE002630A 40°C 0°C
1-26W 120V DC 26W WALL OR CEILING NWPFE0026DC120A 40°C 0°C
Provlded with one 3/4 aluminum hub as standard. T-code measurements taken in 40°C ambient; operating ambient reduced for normal and emergency models to
maintain battery performance.
Class I, Div. 2, Groups A, B, C, DClass I, Zone 2, Groups IIC, IIB, IIAClass II, Div. I, Groups F, GClass IIIMarineNEMA 3, 4, 4X IP66
C e r t i fi e d - F i l e L R 117 13
Catalog Number LogicCatalog Number Logic Constant for NWP seriesPower & Ballast TypeFN – Fluorescent Normal PowerFE – Fluorescent w/ Battery Backup
Supply (input) voltage30 - 120-277V 50/60HzDC120 - FN26
Hubs & AccessoriesA – 3/4” Single Entry aluminumP – 3/4” Single Entry PVC coated zincS – 3/4” Single Entry Stainless SteelM – M20 single entry*AA – 3/4” Feed-Thru, AluminumPP – 3/4” Feed-Thru, PVC Coated ZincSS – 3/4” Feed-Thru, Stainless SteelMM – M20 Feed-Thru entry*PI – Photocell 120V**P2 – Photocell 208-277V**
Lamp Wattage13-13W (AC Normal only operation)18-18W (AC Normal only operation)26-26W (AC or DC Normal only operation)1313-13W (AC ballast w/ battery backup)1818-18W (AC ballast w/ battery backup)0013-13W Emergency only0018-18W Emergency only0026-26W Emergency only
NWP 00 00(00) 00(00) ?
Notes: * ** Photocells for FN Models only – Class *, Div. 2
NEMA 4X only.
Surface Mount Luminaires 13-26W Fluorescent
Wall Mounted
Ceiling Mounted
Exit Sign
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK FITTINGS
H A Z LO C
H A Z LO C
FITTINGS
FITTINGS
EYD SERIES
DRAIN SEALING FITTING
EYD-75M EYD-75TM
Class I, Div. 1 & 2, Groups B, C, D Class I, Zone 1, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups E, F, G Class III
C e r t i fi e d
Applications
To seal and drain vertical conduits. To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit.
Features
• Threaded for Rigid Conduit or IMC• Tapered threads (NPT)• Simple to install. Internal drainage path
provides a visual means to ensure that the compound chamber is properly filled. No need to use hoses and wires
• Large cover openings for easy packing of fiber dam on 1/2” through 1” sizes
• Temporary plastic sleeve protects thread for drain/breather from contamination when pouring compound
• Unique design enables installation of drain/breather right after compound is poured – no waiting
• Provides continuous water drain path while allowing conduit run to breathe, in compliance with the NEC
• Includes Drain Breather Fitting KDB-375
Material/Finish
Copper-free Aluminum (less than 4/10 of 1%)• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chromate sealant, and electro-statically applied powder coating
EYD EYD with Nipple
FEATURES-SPECIFICATIONS EYD DRAIN SEALING FITTINGS
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)KILLARK ALUMINUM A B
1/2” EYD-50 3-1/2”(89) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75 3-3/4”(95) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100 4-3/8”(111) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS WITH NIPPLE
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)KILLARK ALUMINUM A B
1/2” EYD-50T 4-3/8”(111) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75T 4-5/8”(118) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100T 5-1/2”(140) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS – IRON
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)DURALOY IRON A B
1/2” EYD-50M 3-1/2”(89) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75M 3-3/4”(95) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100M 4-3/8”(111) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
EYD DRAIN SEALING FITTINGS WITH NIPPLE – IRON
HUB SIZE
CATALOG NUMBER DIMENSIONS TURNINGRADIUS*
SEALING COMPOUND REQUIRED
PER HUB (PF)DURALOY IRON A B
1/2” EYD-50TM 4-3/8”(111) 1-1/8”(29) 1-5/8”(41) 1-1/4 oz. 1/32 oz.3/4” EYD-75TM 4-5/8”(118) 1-3/8”(35) 1-3/4”(45) 2 oz. 1/16 oz.1” EYD-100TM 5-1/2”(140) 1-3/4”(45) 2-1/8”(54) 4 oz. 1/8 oz.
* Turning radius with plug removed.
NEW!DRAIN SEAL
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
NWP SERIES
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES
FEATURES-SPECIFICATIONSApplications
Killark’s NWP Series of fluorescent luminaires are designed for task lighting of wet & corrosive NEMA 4X environments and hazardous locations.
Typical uses include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, agricultural, commercial, industrial, and mining facilities.
NWP surface mount luminaires contain no exposed glass and carry Class II, F&G ratings required for many food proccessing areas.
Features
• Non-metallic housing has a lightweight yet robust low profile construction
• Can be wall mounted or ceiling mounted in horizontal or vertical position
• Energy and labor saving fluorescent• Emergency and normal power models
available.• Emergency version has internal battery
which provides 90 minutes of illumination in the event of a power failure
• Resists corrosive effects of most chemicals, hydrocarbons and solvents
• Designed for indoor and outdoor applications• Includes fluorescent lamp• ‘World Voltage’ ballasts for 120VAC through
277VAC 50/60Hz installations• Wiring terminals are included as standard
Materials
• Enclosure – High strength polycarbonate• Gasket – Silicone• External Hardware – Stainless steel• Lens – Lexan®
• Entry – One ¾” NPT copper-free aluminum hub with ¾ x ½” reducer is standard. A second hub may be purchased separately.
Lexan® is a registered trademark of General Electric
NWP WALLPACK 13-26W FLUORESCENT WLONE 3/4” ALUMINUM HUB
LAMP VOLTAGE DESCRIPTION CAT. NUMBER MAX.AMBIENT SUITIBILITY MIN START
NORMAL POWER MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFN1330A 40°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFN1830A 40°C 15°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFN2630A 40°C 15°C
1-26W 120V DC 26W WALL OR CEILING NWPFN26DC120A 40°C 15°C
NORMAL AND EMERGENCY MODELS1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFE131330A 35°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFE181830A 30°C 15°C
EMERGENCY ONLY MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFEOO1330A 40°C 0°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFEOO1830A 40°C 0°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFE002630A 40°C 0°C
1-26W 120V DC 26W WALL OR CEILING NWPFE0026DC120A 40°C 0°C
Provlded with one 3/4 aluminum hub as standard. T-code measurements taken in 40°C ambient; operating ambient reduced for normal and emergency models to
maintain battery performance.
Class I, Div. 2, Groups A, B, C, DClass I, Zone 2, Groups IIC, IIB, IIAClass II, Div. I, Groups F, GClass IIIMarineNEMA 3, 4, 4X IP66
C e r t i fi e d - F i l e L R 117 13
Catalog Number LogicCatalog Number Logic Constant for NWP seriesPower & Ballast TypeFN – Fluorescent Normal PowerFE – Fluorescent w/ Battery Backup
Supply (input) voltage30 - 120-277V 50/60HzDC120 - FN26
Hubs & AccessoriesA – 3/4” Single Entry aluminumP – 3/4” Single Entry PVC coated zincS – 3/4” Single Entry Stainless SteelM – M20 single entry*AA – 3/4” Feed-Thru, AluminumPP – 3/4” Feed-Thru, PVC Coated ZincSS – 3/4” Feed-Thru, Stainless SteelMM – M20 Feed-Thru entry*PI – Photocell 120V**P2 – Photocell 208-277V**
Lamp Wattage13-13W (AC Normal only operation)18-18W (AC Normal only operation)26-26W (AC or DC Normal only operation)1313-13W (AC ballast w/ battery backup)1818-18W (AC ballast w/ battery backup)0013-13W Emergency only0018-18W Emergency only0026-26W Emergency only
NWP 00 00(00) 00(00) ?
Notes: * ** Photocells for FN Models only – Class *, Div. 2
NEMA 4X only.
Surface Mount Luminaires 13-26W Fluorescent
Wall Mounted
Ceiling Mounted
Exit Sign
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
NWP SERIES
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES
FEATURES-SPECIFICATIONSApplications
Killark’s NWP Series of fluorescent luminaires are designed for task lighting of wet & corrosive NEMA 4X environments and hazardous locations.
Typical uses include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, agricultural, commercial, industrial, and mining facilities.
NWP surface mount luminaires contain no exposed glass and carry Class II, F&G ratings required for many food proccessing areas.
Features
• Non-metallic housing has a lightweight yet robust low profile construction
• Can be wall mounted or ceiling mounted in horizontal or vertical position
• Energy and labor saving fluorescent• Emergency and normal power models
available.• Emergency version has internal battery
which provides 90 minutes of illumination in the event of a power failure
• Resists corrosive effects of most chemicals, hydrocarbons and solvents
• Designed for indoor and outdoor applications• Includes fluorescent lamp• ‘World Voltage’ ballasts for 120VAC through
277VAC 50/60Hz installations• Wiring terminals are included as standard
Materials
• Enclosure – High strength polycarbonate• Gasket – Silicone• External Hardware – Stainless steel• Lens – Lexan®
• Entry – One ¾” NPT copper-free aluminum hub with ¾ x ½” reducer is standard. A second hub may be purchased separately.
Lexan® is a registered trademark of General Electric
NWP WALLPACK 13-26W FLUORESCENT WLONE 3/4” ALUMINUM HUB
LAMP VOLTAGE DESCRIPTION CAT. NUMBER MAX.AMBIENT SUITIBILITY MIN START
NORMAL POWER MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFN1330A 40°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFN1830A 40°C 15°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFN2630A 40°C 15°C
1-26W 120V DC 26W WALL OR CEILING NWPFN26DC120A 40°C 15°C
NORMAL AND EMERGENCY MODELS1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFE131330A 35°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFE181830A 30°C 15°C
EMERGENCY ONLY MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFEOO1330A 40°C 0°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFEOO1830A 40°C 0°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFE002630A 40°C 0°C
1-26W 120V DC 26W WALL OR CEILING NWPFE0026DC120A 40°C 0°C
Provlded with one 3/4 aluminum hub as standard. T-code measurements taken in 40°C ambient; operating ambient reduced for normal and emergency models to
maintain battery performance.
Class I, Div. 2, Groups A, B, C, DClass I, Zone 2, Groups IIC, IIB, IIAClass II, Div. I, Groups F, GClass IIIMarineNEMA 3, 4, 4X IP66
C e r t i fi e d - F i l e L R 117 13
Catalog Number LogicCatalog Number Logic Constant for NWP seriesPower & Ballast TypeFN – Fluorescent Normal PowerFE – Fluorescent w/ Battery Backup
Supply (input) voltage30 - 120-277V 50/60HzDC120 - FN26
Hubs & AccessoriesA – 3/4” Single Entry aluminumP – 3/4” Single Entry PVC coated zincS – 3/4” Single Entry Stainless SteelM – M20 single entry*AA – 3/4” Feed-Thru, AluminumPP – 3/4” Feed-Thru, PVC Coated ZincSS – 3/4” Feed-Thru, Stainless SteelMM – M20 Feed-Thru entry*PI – Photocell 120V**P2 – Photocell 208-277V**
Lamp Wattage13-13W (AC Normal only operation)18-18W (AC Normal only operation)26-26W (AC or DC Normal only operation)1313-13W (AC ballast w/ battery backup)1818-18W (AC ballast w/ battery backup)0013-13W Emergency only0018-18W Emergency only0026-26W Emergency only
NWP 00 00(00) 00(00) ?
Notes: * ** Photocells for FN Models only – Class *, Div. 2
NEMA 4X only.
Surface Mount Luminaires 13-26W Fluorescent
Wall Mounted
Ceiling Mounted
Exit Sign
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
The following products are held in UK stock by Scattergood & Johnson Ltd:Available for next day delivery.
NWPFN1330PPNWPFE131330PPNWP-DECAL01
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
NWP SERIES
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES
FEATURES-SPECIFICATIONSApplications
Killark’s NWP Series of fluorescent luminaires are designed for task lighting of wet & corrosive NEMA 4X environments and hazardous locations.
Typical uses include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, agricultural, commercial, industrial, and mining facilities.
NWP surface mount luminaires contain no exposed glass and carry Class II, F&G ratings required for many food proccessing areas.
Features
• Non-metallic housing has a lightweight yet robust low profile construction
• Can be wall mounted or ceiling mounted in horizontal or vertical position
• Energy and labor saving fluorescent• Emergency and normal power models
available.• Emergency version has internal battery
which provides 90 minutes of illumination in the event of a power failure
• Resists corrosive effects of most chemicals, hydrocarbons and solvents
• Designed for indoor and outdoor applications• Includes fluorescent lamp• ‘World Voltage’ ballasts for 120VAC through
277VAC 50/60Hz installations• Wiring terminals are included as standard
Materials
• Enclosure – High strength polycarbonate• Gasket – Silicone• External Hardware – Stainless steel• Lens – Lexan®
• Entry – One ¾” NPT copper-free aluminum hub with ¾ x ½” reducer is standard. A second hub may be purchased separately.
Lexan® is a registered trademark of General Electric
NWP WALLPACK 13-26W FLUORESCENT WLONE 3/4” ALUMINUM HUB
LAMP VOLTAGE DESCRIPTION CAT. NUMBER MAX.AMBIENT SUITIBILITY MIN START
NORMAL POWER MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFN1330A 40°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFN1830A 40°C 15°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFN2630A 40°C 15°C
1-26W 120V DC 26W WALL OR CEILING NWPFN26DC120A 40°C 15°C
NORMAL AND EMERGENCY MODELS1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFE131330A 35°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFE181830A 30°C 15°C
EMERGENCY ONLY MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFEOO1330A 40°C 0°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFEOO1830A 40°C 0°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFE002630A 40°C 0°C
1-26W 120V DC 26W WALL OR CEILING NWPFE0026DC120A 40°C 0°C
Provlded with one 3/4 aluminum hub as standard. T-code measurements taken in 40°C ambient; operating ambient reduced for normal and emergency models to
maintain battery performance.
Class I, Div. 2, Groups A, B, C, DClass I, Zone 2, Groups IIC, IIB, IIAClass II, Div. I, Groups F, GClass IIIMarineNEMA 3, 4, 4X IP66
C e r t i fi e d - F i l e L R 117 13
Catalog Number LogicCatalog Number Logic Constant for NWP seriesPower & Ballast TypeFN – Fluorescent Normal PowerFE – Fluorescent w/ Battery Backup
Supply (input) voltage30 - 120-277V 50/60HzDC120 - FN26
Hubs & AccessoriesA – 3/4” Single Entry aluminumP – 3/4” Single Entry PVC coated zincS – 3/4” Single Entry Stainless SteelM – M20 single entry*AA – 3/4” Feed-Thru, AluminumPP – 3/4” Feed-Thru, PVC Coated ZincSS – 3/4” Feed-Thru, Stainless SteelMM – M20 Feed-Thru entry*PI – Photocell 120V**P2 – Photocell 208-277V**
Lamp Wattage13-13W (AC Normal only operation)18-18W (AC Normal only operation)26-26W (AC or DC Normal only operation)1313-13W (AC ballast w/ battery backup)1818-18W (AC ballast w/ battery backup)0013-13W Emergency only0018-18W Emergency only0026-26W Emergency only
NWP 00 00(00) 00(00) ?
Notes: * ** Photocells for FN Models only – Class *, Div. 2
NEMA 4X only.
Surface Mount Luminaires 13-26W Fluorescent
Wall Mounted
Ceiling Mounted
Exit Sign
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
NWP SERIES
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES
FEATURES-SPECIFICATIONSApplications
Killark’s NWP Series of fluorescent luminaires are designed for task lighting of wet & corrosive NEMA 4X environments and hazardous locations.
Typical uses include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, agricultural, commercial, industrial, and mining facilities.
NWP surface mount luminaires contain no exposed glass and carry Class II, F&G ratings required for many food proccessing areas.
Features
• Non-metallic housing has a lightweight yet robust low profile construction
• Can be wall mounted or ceiling mounted in horizontal or vertical position
• Energy and labor saving fluorescent• Emergency and normal power models
available.• Emergency version has internal battery
which provides 90 minutes of illumination in the event of a power failure
• Resists corrosive effects of most chemicals, hydrocarbons and solvents
• Designed for indoor and outdoor applications• Includes fluorescent lamp• ‘World Voltage’ ballasts for 120VAC through
277VAC 50/60Hz installations• Wiring terminals are included as standard
Materials
• Enclosure – High strength polycarbonate• Gasket – Silicone• External Hardware – Stainless steel• Lens – Lexan®
• Entry – One ¾” NPT copper-free aluminum hub with ¾ x ½” reducer is standard. A second hub may be purchased separately.
Lexan® is a registered trademark of General Electric
NWP WALLPACK 13-26W FLUORESCENT WLONE 3/4” ALUMINUM HUB
LAMP VOLTAGE DESCRIPTION CAT. NUMBER MAX.AMBIENT SUITIBILITY MIN START
NORMAL POWER MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFN1330A 40°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFN1830A 40°C 15°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFN2630A 40°C 15°C
1-26W 120V DC 26W WALL OR CEILING NWPFN26DC120A 40°C 15°C
NORMAL AND EMERGENCY MODELS1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFE131330A 35°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFE181830A 30°C 15°C
EMERGENCY ONLY MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFEOO1330A 40°C 0°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFEOO1830A 40°C 0°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFE002630A 40°C 0°C
1-26W 120V DC 26W WALL OR CEILING NWPFE0026DC120A 40°C 0°C
Provlded with one 3/4 aluminum hub as standard. T-code measurements taken in 40°C ambient; operating ambient reduced for normal and emergency models to
maintain battery performance.
Class I, Div. 2, Groups A, B, C, DClass I, Zone 2, Groups IIC, IIB, IIAClass II, Div. I, Groups F, GClass IIIMarineNEMA 3, 4, 4X IP66
C e r t i fi e d - F i l e L R 117 13
Catalog Number LogicCatalog Number Logic Constant for NWP seriesPower & Ballast TypeFN – Fluorescent Normal PowerFE – Fluorescent w/ Battery Backup
Supply (input) voltage30 - 120-277V 50/60HzDC120 - FN26
Hubs & AccessoriesA – 3/4” Single Entry aluminumP – 3/4” Single Entry PVC coated zincS – 3/4” Single Entry Stainless SteelM – M20 single entry*AA – 3/4” Feed-Thru, AluminumPP – 3/4” Feed-Thru, PVC Coated ZincSS – 3/4” Feed-Thru, Stainless SteelMM – M20 Feed-Thru entry*PI – Photocell 120V**P2 – Photocell 208-277V**
Lamp Wattage13-13W (AC Normal only operation)18-18W (AC Normal only operation)26-26W (AC or DC Normal only operation)1313-13W (AC ballast w/ battery backup)1818-18W (AC ballast w/ battery backup)0013-13W Emergency only0018-18W Emergency only0026-26W Emergency only
NWP 00 00(00) 00(00) ?
Notes: * ** Photocells for FN Models only – Class *, Div. 2
NEMA 4X only.
Surface Mount Luminaires 13-26W Fluorescent
Wall Mounted
Ceiling Mounted
Exit Sign
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
NWP SERIES
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES
FEATURES-SPECIFICATIONSApplications
Killark’s NWP Series of fluorescent luminaires are designed for task lighting of wet & corrosive NEMA 4X environments and hazardous locations.
Typical uses include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, agricultural, commercial, industrial, and mining facilities.
NWP surface mount luminaires contain no exposed glass and carry Class II, F&G ratings required for many food proccessing areas.
Features
• Non-metallic housing has a lightweight yet robust low profile construction
• Can be wall mounted or ceiling mounted in horizontal or vertical position
• Energy and labor saving fluorescent• Emergency and normal power models
available.• Emergency version has internal battery
which provides 90 minutes of illumination in the event of a power failure
• Resists corrosive effects of most chemicals, hydrocarbons and solvents
• Designed for indoor and outdoor applications• Includes fluorescent lamp• ‘World Voltage’ ballasts for 120VAC through
277VAC 50/60Hz installations• Wiring terminals are included as standard
Materials
• Enclosure – High strength polycarbonate• Gasket – Silicone• External Hardware – Stainless steel• Lens – Lexan®
• Entry – One ¾” NPT copper-free aluminum hub with ¾ x ½” reducer is standard. A second hub may be purchased separately.
Lexan® is a registered trademark of General Electric
NWP WALLPACK 13-26W FLUORESCENT WLONE 3/4” ALUMINUM HUB
LAMP VOLTAGE DESCRIPTION CAT. NUMBER MAX.AMBIENT SUITIBILITY MIN START
NORMAL POWER MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFN1330A 40°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFN1830A 40°C 15°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFN2630A 40°C 15°C
1-26W 120V DC 26W WALL OR CEILING NWPFN26DC120A 40°C 15°C
NORMAL AND EMERGENCY MODELS1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFE131330A 35°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFE181830A 30°C 15°C
EMERGENCY ONLY MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFEOO1330A 40°C 0°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFEOO1830A 40°C 0°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFE002630A 40°C 0°C
1-26W 120V DC 26W WALL OR CEILING NWPFE0026DC120A 40°C 0°C
Provlded with one 3/4 aluminum hub as standard. T-code measurements taken in 40°C ambient; operating ambient reduced for normal and emergency models to
maintain battery performance.
Class I, Div. 2, Groups A, B, C, DClass I, Zone 2, Groups IIC, IIB, IIAClass II, Div. I, Groups F, GClass IIIMarineNEMA 3, 4, 4X IP66
C e r t i fi e d - F i l e L R 117 13
Catalog Number LogicCatalog Number Logic Constant for NWP seriesPower & Ballast TypeFN – Fluorescent Normal PowerFE – Fluorescent w/ Battery Backup
Supply (input) voltage30 - 120-277V 50/60HzDC120 - FN26
Hubs & AccessoriesA – 3/4” Single Entry aluminumP – 3/4” Single Entry PVC coated zincS – 3/4” Single Entry Stainless SteelM – M20 single entry*AA – 3/4” Feed-Thru, AluminumPP – 3/4” Feed-Thru, PVC Coated ZincSS – 3/4” Feed-Thru, Stainless SteelMM – M20 Feed-Thru entry*PI – Photocell 120V**P2 – Photocell 208-277V**
Lamp Wattage13-13W (AC Normal only operation)18-18W (AC Normal only operation)26-26W (AC or DC Normal only operation)1313-13W (AC ballast w/ battery backup)1818-18W (AC ballast w/ battery backup)0013-13W Emergency only0018-18W Emergency only0026-26W Emergency only
NWP 00 00(00) 00(00) ?
Notes: * ** Photocells for FN Models only – Class *, Div. 2
NEMA 4X only.
Surface Mount Luminaires 13-26W Fluorescent
Wall Mounted
Ceiling Mounted
Exit Sign
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
LZ2N SERIES
NON-METALLIC FLUORESCENT FIXTURES
Class I, Div. 2 Groups A, B, C, DClass l, Zones 2, Groups IIC, llB, llAClass II, Div. 1 & 2, Groups F, GAEx nAII, Ex nAIIWet LocationsNEMA 4X, IP66
4’ Nominal Style
2’ Nominal Style
Type ApprovalABSFood HandlingNSF
Quick release diffuser clamp and hinged cover requires no special tools.
Applications
LINEARLITE ® rugged Non-Metallic fluorescent fixtures are suitable for wet, harsh and hazardous locations. Use where enclosed and gasketed fixtures are required to withstand exposure to moisture, dust and corrosives. The LZ2N Series can also be used in Class I, Division 2 and Zone 2 hazarous vapors and in Class II areas where combustible dusts may exist. Typical areas used are in refineries, chemical plants, waste water & sewage treatment facilities, as well as in tunnels, food processing and coastal areas.
ABS (American Bureau of Shipping) type approval for use on decks, vessels, platforms, barges, ships and boats. Also suitable for docks and marinas.
NSF (National Sanitation Foundation) approved for “Food Handling” areas, typically requiring non-glass lighting.
Features
• Housing – one piece fiberglass reinforced polyester, NEMA 4X & IP66 rated.
• Lexan® Clear Lens, impact resistant polycarbonate
• Two 3/4” NTP aluminum hubs – one at each end (includes one 3/4” close-up plug and two 3/4” x 1/2” reducers for maximum user flexibility)
• Two 1/4”-20 aluminum bushings furnished in top of fixture for threaded rod
• 2’ and 4’ luminaries• Lamp types –
Linear 17, 28, 32, 40, 44, 54, 60W Long compact 40, 55W (single ended)
• Electronic ballast standard• World voltage (most models) 120 thru
277V, 50/60 HzLexan® is a registered trademark of General Electric
Catalog Number Logic
Constant for LZ2N SeriesEmergency (Battery backed)E1 – 40W BIAXIAL, 44W, 60WE2 – 32W, 40WLamp Wattage17283240-Linear & BIAXIAL44545560
Voltage30 – 120-277V 50/60 Hz40, 55 - BIAXIAL 17, 28, 32, 44, 54W01 – 120V 60 Hz 40W, 60W04 – 277V 60 Hz 40W, 60W08 – 230V 50 Hz 40W15 – 347V 60 Hz 32W
LZ2N (E0-) 00 000 F
1 lamp2 lamps3 lamps4 lamps
F – single fuseFF – double fuse QD – Quick Disconnect55C
See page L227 for complete catalog grid listing. Fuses not for marine or Canadian use. 55°C ambient suitability 2 or 3 lamp 32W C1D2 120V-277V only.
LZ2N/LZ2S luminaires contain no exposed glass and carry Class II, “G” ratings required for many food proccessing areas.
C e r t i fi e d - F i l e L R 117 13
FEATURES-SPECIFICATIONS
LZ2N, LZ2NE HAZARDOUS LOCATION APPLICATION DATA
NUMBER OF LAMPS/WATTS
RATED AMBIENT
°C
SUITABLE FOR °C SUPPLY
WIRE
CLASS I, DIV. 2 MAX SURFACE TEMP.
CLASS II, DIV. 1 & 2 MAX. SURFACE TEMP. CLASS III,
DIV. 1 & 2SUITABILITY
NEMA 4X
IP66TEMP. T-CODE GROUPS TEMP. T-CODE GROUPS
2 x 17W 40° 60 85°C T5 A, B, C, D 100°C T5 F, G Yes Yes3 x 17W 40° 60 85°C T5 A, B, C, D 100°C T5 F, G Yes Yes
1 x 40W BIAXIAL 40° 60 100°C T5 A, B, C, D 100°C T5 F, G Yes Yes1 x 55W BIAXIAL 40° 60 160°C T3C A, B, C, D 100°C T5 F, G Yes Yes2 x 40W BIAXIAL 40° 60 100°C T5 A, B, C, D 100°C T5 F, G Yes Yes4 x 40W BIAXIAL 40° 60 120°C T4A A, B, C, D 100°C T5 F, G Yes Yes
2 x 28W 40° 60 120°C T4A A, B, C, D 100°C T5 F, G Yes Yes3 x 28W 40° 60 120°C T4A A, B, C, D 100°C T5 F, G Yes Yes2 x 32W 40° 75 85°C T6 A, B, C, D 100°C T5 F, G Yes Yes
2 x 32W 55° 90 100°C T5 A, B, C, D N/A N/A N/A Yes Yes
3 x 32W 40° 75 85°C T6 A, B, C, D 100°C T5 F, G Yes Yes
3 x 32W 55° 90 100°C T5 A, B, C, D N/A N/A N/A Yes Yes
2 x 40W 40° 60 120°C T4A A, B, C, D 100°C T5 F, G Yes Yes2 x 44W 40° 60 100°C T5 A, B, C, D 100°C T5 F, G Yes Yes
2 x 54W T5 40° 75 160°C T3C A, B, C, D 100°C T5 F, G Yes Yes3 x 54W T5 40° 75 180°C T3A A, B, C, D 120°C T4A F, G Yes Yes
2 x 60W 40° 75 135°C T4 A, B, C, D 100°C T5 F, G Yes Yes
LZ2NE, 40°C max. battery models.
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
KILLARK LIGHTING
H A Z LO C
H A Z LO C
LIGHTING
LIGHTING
NWP SERIES
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES
FEATURES-SPECIFICATIONSApplications
Killark’s NWP Series of fluorescent luminaires are designed for task lighting of wet & corrosive NEMA 4X environments and hazardous locations.
Typical uses include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, agricultural, commercial, industrial, and mining facilities.
NWP surface mount luminaires contain no exposed glass and carry Class II, F&G ratings required for many food proccessing areas.
Features
• Non-metallic housing has a lightweight yet robust low profile construction
• Can be wall mounted or ceiling mounted in horizontal or vertical position
• Energy and labor saving fluorescent• Emergency and normal power models
available.• Emergency version has internal battery
which provides 90 minutes of illumination in the event of a power failure
• Resists corrosive effects of most chemicals, hydrocarbons and solvents
• Designed for indoor and outdoor applications• Includes fluorescent lamp• ‘World Voltage’ ballasts for 120VAC through
277VAC 50/60Hz installations• Wiring terminals are included as standard
Materials
• Enclosure – High strength polycarbonate• Gasket – Silicone• External Hardware – Stainless steel• Lens – Lexan®
• Entry – One ¾” NPT copper-free aluminum hub with ¾ x ½” reducer is standard. A second hub may be purchased separately.
Lexan® is a registered trademark of General Electric
NWP WALLPACK 13-26W FLUORESCENT WLONE 3/4” ALUMINUM HUB
LAMP VOLTAGE DESCRIPTION CAT. NUMBER MAX.AMBIENT SUITIBILITY MIN START
NORMAL POWER MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFN1330A 40°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFN1830A 40°C 15°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFN2630A 40°C 15°C
1-26W 120V DC 26W WALL OR CEILING NWPFN26DC120A 40°C 15°C
NORMAL AND EMERGENCY MODELS1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFE131330A 35°C 15°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFE181830A 30°C 15°C
EMERGENCY ONLY MODELS - AMBIENT SUITABILITY 40°C MAX.1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFEOO1330A 40°C 0°C1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFEOO1830A 40°C 0°C1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFE002630A 40°C 0°C
1-26W 120V DC 26W WALL OR CEILING NWPFE0026DC120A 40°C 0°C
Provlded with one 3/4 aluminum hub as standard. T-code measurements taken in 40°C ambient; operating ambient reduced for normal and emergency models to
maintain battery performance.
Class I, Div. 2, Groups A, B, C, DClass I, Zone 2, Groups IIC, IIB, IIAClass II, Div. I, Groups F, GClass IIIMarineNEMA 3, 4, 4X IP66
C e r t i fi e d - F i l e L R 117 13
Catalog Number LogicCatalog Number Logic Constant for NWP seriesPower & Ballast TypeFN – Fluorescent Normal PowerFE – Fluorescent w/ Battery Backup
Supply (input) voltage30 - 120-277V 50/60HzDC120 - FN26
Hubs & AccessoriesA – 3/4” Single Entry aluminumP – 3/4” Single Entry PVC coated zincS – 3/4” Single Entry Stainless SteelM – M20 single entry*AA – 3/4” Feed-Thru, AluminumPP – 3/4” Feed-Thru, PVC Coated ZincSS – 3/4” Feed-Thru, Stainless SteelMM – M20 Feed-Thru entry*PI – Photocell 120V**P2 – Photocell 208-277V**
Lamp Wattage13-13W (AC Normal only operation)18-18W (AC Normal only operation)26-26W (AC or DC Normal only operation)1313-13W (AC ballast w/ battery backup)1818-18W (AC ballast w/ battery backup)0013-13W Emergency only0018-18W Emergency only0026-26W Emergency only
NWP 00 00(00) 00(00) ?
Notes: * ** Photocells for FN Models only – Class *, Div. 2
NEMA 4X only.
Surface Mount Luminaires 13-26W Fluorescent
Wall Mounted
Ceiling Mounted
Exit Sign
WWW.SCATTS.CO.UKWWW.HUBBELL-KILLARK.COM
The following products are held in UK stock by Scattergood & Johnson Ltd:Available for next day delivery.
LZ2N17230LZ2N32230
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
FEATURES-SPECIFICATIONS
Items in this column are suitable for Class I, Group B in addition to Class I, Groups C, D. Also suitable for Class I, Zone 1, Groups IIB+H2, IIA. Seals must be installed within 6 inches of conduit opening. Items in this column may also be used in Class I, Zone 1, Groups IIB, IIA. Assembly numbers not rated for Group B are shipped as receptacle & back box components. Canadian Codes now allow “T” combination slots for 15A or 20A plugs. Check breaker and wire feed size for proper application ratings.
NOTE: For replacement receptacle cover and hinge, order KIT-173.
RECEPTACLES AND ASSEMBLIESNEMA RATING & CONFIGURATION ENCLOSURE STYLE HUB SIZE SINGLE GANG
GROUPS C, D, F, & GDOUBLE GANG GROUPS C D, F, & G
SINGLE GANG GROUPS B, C, D, F & G
20 Amp125 Volt
5-20R
2 POLE 3 WIRE
RECEPTACLE ONLY – UGRO-20231 UGRO-20231 –
DEAD END1/2" UGR1-20231 UGR7-20231 UGRB1-202313/4" UGR2-20231 UGR8-20231 UGRB2-202311" UGR3-20231 UGR9-20231 UGRB3-20231
FEED-THRU
1/2” UGR4-20231 UGR10-20231 UGRB4-202313/4" UGR5-20231 UGR11-20231 UGRB5-20231
1" UGR6-20231 UGR12-20231 UGRB6-20231
15 Amp125 Volt
5-15R
2 POLE 3 WIRE
RECEPTACLE ONLY – UGROC-15231 UGROC-15231 –
DEAD END1/2" UGR1C-15231 UGR7C-15231 UGRB1C-152313/4" UGR2C-15231 UGR8C-15231 UGRB2C-152311" UGR3C-15231 UGR9C-15231 UGRB3C-15231
FEED-THRU
1/2” UGR4C-15231 UGR10C-15231 UGRB4C-152313/4" UGR5C-15231 UGR11C-15231 UGRB5C-15231
1" UGR6C-15231 UGR12C-15231 UGRB6C-15231
20 Amp250 Volt
6-20R
2 POLE 3 WIRE
RECEPTACLE ONLY – UGRO-20232 UGRO-20232 –
DEAD END1/2" UGR1-20232 UGR7-20232 UGRB1-202323/4" UGR2-20232 UGR8-20232 UGRB2-202321" UGR3-20232 UGR9-20232 UGRB3-20232
FEED-THRU1/2” UGR4-20232 UGR10-20232 UGRB4-202323/4" UGR5-20232 UGR11-20232 UGRB5-202321" UGR6-20232 UGR12-20232 UGRB6-20232
15 Amp250 Volt
6-15R
2 POLE 3 WIRE
RECEPTACLE ONLY – UGROC-15232 UGROC-15232 –
DEAD END1/2" UGR1C-15232 UGR7C-15232 UGRB1C-152323/4" UGR2C-15232 UGR8C-15232 UGRB2C-152321" UGR3C-15232 UGR9C-15232 UGRB3C-15232
FEED-THRU
1/2” UGR4C-15232 UGR10C-15232 UGRB4C-152323/4" UGR5C-15232 UGR11C-15232 UGRB5C-15232
1" UGR6C-15232 UGR12C-15232 UGRB6C-15232
SWB-1, 2, 3 SWB-4, 5, 6 Single Gang Double Gang
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
VSQ & VWSQ INTERLOCKED SWITCHED RECEPTACLES
VERSAMATE® SERIES
• VSQ Hazardous Location Ratings Class I, Div. 1 & 2, Groups B, C, D Class I, Zones I & 2, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups F & G Class lll NEMA 3, 4, 4X, 7 (B, C, D), 9 (F, G)
• N4X with receptacle lid turned shut or with plug locking ring tightened
• Copper-free aluminum construction with electrostatically applied polyester/epoxy finish. Handle mechanism is chemical resistant Valox® (TM General Electric).
• Compact size and footprint• Plug Interlock Mechanism for Deadfront
construction. Switch cannot be turned “ON” without fully inserted plug. Plug cannot be removed with switch in “ON” position
• Plug held in place when switch is “Off” for convenience. Pull operated release mechanism. Plug and wiring do not have to be twisted or held to operate switch
• Factory Wired Receptacle; easy to wire line side of switch
• Easily visible “On-Off” indicator handle• “Off” position is padlockable for
maintenance safety• Auxiliary Contact (late-make early-break)
contact rated 10 Amp, 1/3 HP at 125/250 VAC. Can be used for operating pilot lights or starter coils (standard model only)
• VWSQ for Wet & Corrosive Locations NEMA 3, 4, 4X
Wire Range3 0 A m p R e g u l a r S t r a n d in g M a x # 10
6 0 A m p R e g u l a r S t r a n d in g M a x # 4
Dimensions shown are in inches for 30 AMP: 60 Amp dimensions in ( ).
NOTES: Devices have adjustable ductile lugs (vertical or side) for attachment to uneven surfaces.
60A devices have terminal blocks.
Dimensions
F i l e N o . L R 14 6 6 7V S Q
F i l e N o . E 9 10 4 9V W S Q
FEATURES-SPECIFICATIONS
VersaMate VSQ & VWSQ Receptacles use VersaMate Style II plugs found on pages PR6 & PR7 and are
Arktite® or Appleton® Powertite® plugs (when installed in accordance with instructions furnished with device)
Arktite® is a registered trademark of Crouse-Hinds®.
Powertite® is a registered trademark of Appleton®.
MODIFICATIONS*CATALOG NUMBER DESCRIPTION
S37 Polarization for receptacles, plugs * See page PR5 for more information on this option
• Feed-through construction• Horsepower Rated• Internal switch horsepower rated as
“motor disconnect”
HORSEPOWER RATINGS (VAC) 120 240 480 600
30A1Ø 2 5 10 153Ø 3 7.5 15 20
60A1Ø – 10 15 203Ø – 10 25 30
VSQ & VWSQ RECEPTACLES
AMPS CIRCUITCATALOG NUMBER
VSQ HAZARDOUS VWSQ N4X ONLY VERSAMATE PLUG
302W3P VSQ3023 VWSQ3023 VP33853W4P VSQ3034 VWSQ3034 VP3485
602W3P VSQ6023 VWSQ6023 VP63853W4P VSQ6034 VWSQ6034 VP6485
NOTES: VSQ/VWSQ 30 Amp models come standard with 1” drilled and tapped conduit openings top and bottom
60 amp models come with 1-1/2” openings top and bottom and one 1-1/2” close-up plug.
VSQ & VWSQ Receptacle covers are NOT interchangeable.
Refers to internal switch only.
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
FEATURES-SPECIFICATIONS
Items in this column are suitable for Class I, Group B in addition to Class I, Groups C, D. Also suitable for Class I, Zone 1, Groups IIB+H2, IIA. Seals must be installed within 6 inches of conduit opening. Items in this column may also be used in Class I, Zone 1, Groups IIB, IIA. Assembly numbers not rated for Group B are shipped as receptacle & back box components. Canadian Codes now allow “T” combination slots for 15A or 20A plugs. Check breaker and wire feed size for proper application ratings.
NOTE: For replacement receptacle cover and hinge, order KIT-173.
RECEPTACLES AND ASSEMBLIESNEMA RATING & CONFIGURATION ENCLOSURE STYLE HUB SIZE SINGLE GANG
GROUPS C, D, F, & GDOUBLE GANG GROUPS C D, F, & G
SINGLE GANG GROUPS B, C, D, F & G
20 Amp125 Volt
5-20R
2 POLE 3 WIRE
RECEPTACLE ONLY – UGRO-20231 UGRO-20231 –
DEAD END1/2" UGR1-20231 UGR7-20231 UGRB1-202313/4" UGR2-20231 UGR8-20231 UGRB2-202311" UGR3-20231 UGR9-20231 UGRB3-20231
FEED-THRU
1/2” UGR4-20231 UGR10-20231 UGRB4-202313/4" UGR5-20231 UGR11-20231 UGRB5-20231
1" UGR6-20231 UGR12-20231 UGRB6-20231
15 Amp125 Volt
5-15R
2 POLE 3 WIRE
RECEPTACLE ONLY – UGROC-15231 UGROC-15231 –
DEAD END1/2" UGR1C-15231 UGR7C-15231 UGRB1C-152313/4" UGR2C-15231 UGR8C-15231 UGRB2C-152311" UGR3C-15231 UGR9C-15231 UGRB3C-15231
FEED-THRU
1/2” UGR4C-15231 UGR10C-15231 UGRB4C-152313/4" UGR5C-15231 UGR11C-15231 UGRB5C-15231
1" UGR6C-15231 UGR12C-15231 UGRB6C-15231
20 Amp250 Volt
6-20R
2 POLE 3 WIRE
RECEPTACLE ONLY – UGRO-20232 UGRO-20232 –
DEAD END1/2" UGR1-20232 UGR7-20232 UGRB1-202323/4" UGR2-20232 UGR8-20232 UGRB2-202321" UGR3-20232 UGR9-20232 UGRB3-20232
FEED-THRU1/2” UGR4-20232 UGR10-20232 UGRB4-202323/4" UGR5-20232 UGR11-20232 UGRB5-202321" UGR6-20232 UGR12-20232 UGRB6-20232
15 Amp250 Volt
6-15R
2 POLE 3 WIRE
RECEPTACLE ONLY – UGROC-15232 UGROC-15232 –
DEAD END1/2" UGR1C-15232 UGR7C-15232 UGRB1C-152323/4" UGR2C-15232 UGR8C-15232 UGRB2C-152321" UGR3C-15232 UGR9C-15232 UGRB3C-15232
FEED-THRU
1/2” UGR4C-15232 UGR10C-15232 UGRB4C-152323/4" UGR5C-15232 UGR11C-15232 UGRB5C-15232
1" UGR6C-15232 UGR12C-15232 UGRB6C-15232
SWB-1, 2, 3 SWB-4, 5, 6 Single Gang Double Gang
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
VSQ & VWSQ INTERLOCKED SWITCHED RECEPTACLES
VERSAMATE® SERIES
• VSQ Hazardous Location Ratings Class I, Div. 1 & 2, Groups B, C, D Class I, Zones I & 2, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups F & G Class lll NEMA 3, 4, 4X, 7 (B, C, D), 9 (F, G)
• N4X with receptacle lid turned shut or with plug locking ring tightened
• Copper-free aluminum construction with electrostatically applied polyester/epoxy finish. Handle mechanism is chemical resistant Valox® (TM General Electric).
• Compact size and footprint• Plug Interlock Mechanism for Deadfront
construction. Switch cannot be turned “ON” without fully inserted plug. Plug cannot be removed with switch in “ON” position
• Plug held in place when switch is “Off” for convenience. Pull operated release mechanism. Plug and wiring do not have to be twisted or held to operate switch
• Factory Wired Receptacle; easy to wire line side of switch
• Easily visible “On-Off” indicator handle• “Off” position is padlockable for
maintenance safety• Auxiliary Contact (late-make early-break)
contact rated 10 Amp, 1/3 HP at 125/250 VAC. Can be used for operating pilot lights or starter coils (standard model only)
• VWSQ for Wet & Corrosive Locations NEMA 3, 4, 4X
Wire Range3 0 A m p R e g u l a r S t r a n d in g M a x # 10
6 0 A m p R e g u l a r S t r a n d in g M a x # 4
Dimensions shown are in inches for 30 AMP: 60 Amp dimensions in ( ).
NOTES: Devices have adjustable ductile lugs (vertical or side) for attachment to uneven surfaces.
60A devices have terminal blocks.
Dimensions
F i l e N o . L R 14 6 6 7V S Q
F i l e N o . E 9 10 4 9V W S Q
FEATURES-SPECIFICATIONS
VersaMate VSQ & VWSQ Receptacles use VersaMate Style II plugs found on pages PR6 & PR7 and are
Arktite® or Appleton® Powertite® plugs (when installed in accordance with instructions furnished with device)
Arktite® is a registered trademark of Crouse-Hinds®.
Powertite® is a registered trademark of Appleton®.
MODIFICATIONS*CATALOG NUMBER DESCRIPTION
S37 Polarization for receptacles, plugs * See page PR5 for more information on this option
• Feed-through construction• Horsepower Rated• Internal switch horsepower rated as
“motor disconnect”
HORSEPOWER RATINGS (VAC) 120 240 480 600
30A1Ø 2 5 10 153Ø 3 7.5 15 20
60A1Ø – 10 15 203Ø – 10 25 30
VSQ & VWSQ RECEPTACLES
AMPS CIRCUITCATALOG NUMBER
VSQ HAZARDOUS VWSQ N4X ONLY VERSAMATE PLUG
302W3P VSQ3023 VWSQ3023 VP33853W4P VSQ3034 VWSQ3034 VP3485
602W3P VSQ6023 VWSQ6023 VP63853W4P VSQ6034 VWSQ6034 VP6485
NOTES: VSQ/VWSQ 30 Amp models come standard with 1” drilled and tapped conduit openings top and bottom
60 amp models come with 1-1/2” openings top and bottom and one 1-1/2” close-up plug.
VSQ & VWSQ Receptacle covers are NOT interchangeable.
Refers to internal switch only.
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
30 AMP NEMA 4X METALLIC
VERSAMATE® SERIES
Back Box Dimensions
VRDVRC
C
D
Receptacle
E
Connector
Plug
in accordance with instructions furnished with device). Assemblies containing components from other manufacturers would have the NEMA type rating of the lowest rated device.
such as VersaMate VSQ/VBQ.
– Note, 2, 3 & 4 pole device dimensions are the same. 30 Amp Back Boxes are available in 1/2”, 3/4” and 1” conduit sizes. Size listed for 3/4”. For other available
sizes, change the BOLD “2” in either the assembly or box only number to: 1=1/2”, 2=3/4”, 3=1”. Assembly
Plug
Connector
3116
2316
314223
32
31332
31332 223
32
Receptacle
plug (or connector) over a wide range of cable diameters (competitors often need two – requiring
additional sizing decisions).
• 30 Amp 600VAC/250VDC; 50-400 Hertz NEMA 3, 4, 4X
• PLUGS ONLY: Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D Class l, Zones 1 & 2, llB+H2, llA Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
Wire RangeR e g u l a r S t r a n d in g : # 10 - # 6 o r i g i n a l s t y l e o r “AT ” t y p e
E x t r a fl e x : # 10 - # 8 o r i g i n a l s t y l e o r “AT ” t y p e
F i l e No . E10757 Ce r t i fied F i l e No . LR111846
Origional or AT Terminals. See PR3 for
more information
FEATURES-SPECIFICATIONS
30 AMP PLUGS & CONNECTORS
GROUND STYLE CIRCUIT GROMMET
RANGE
CATALOG NUMBERPLUG CONNECTOR
ORIG. AT ORIG. AT
Style I2W2P .55 - 1.20 IN VP3275 VP3022 VPR3255 VPR30223W3P .55 - 1.20 IN VP3375 VP3033 VPR3355 VPR30334W4P .55 - 1.20 IN VP3475 VP3044 VPR3455 VPR3044
Style II2W3P .55 - 1.20 IN VP3385 VP3023 VPR3365 VPR30233W4P .55 - 1.20 IN VP3485 VP3034 VPR3465 VPR3034
MODIFICATIONS*CATALOG NUMBER DESCRIPTION
S39 Reverse service for receptacles, plugs & connectorsS37 Polarization for receptacles, plugs & connectors
* See page PR5 for more information on these options.
30 AMP RECEPTACLES & BACK BOXES
GROUNDSTYLE CIRCUIT
CATALOG NUMBERE TYPE C TYPE D TYPE RECEPTACLE ONLY
ORIG. AT ORIG. AT ORIG. AT ORIG. AT
Style I2W2P VR321E2 VR3022E2 VR321C2 VR3022C2 VR321D2 VR3022D2 VR321 VR30223W3P VR331E2 VR3033E2 VR331C2 VR3033C2 VR331D2 VR3033D2 VR331 VR30334W4P VR341E2 VR3044E2 VR341C2 VR3044C2 VR341D2 VR3044D2 VR341 VR3044
Style II2W3P VR332E2 VR3023E2 VR332C2 VR3023C2 VR332D2 VR3023D2 VR332 VR30233W4P VR342E2 VR3034E2 VR342C2 VR3034C2 VR342D2 VR3034D2 VR342 VR3034
Splice box only VRE23 VRE23 VRC23 VRC23 VRD23 VRD23 – –
VRE
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
60 AMP NEMA 4X METALLIC
VERSAMATE® SERIES
C
D
Receptacle
E
Connector
Plug
in accordance with instructions furnished with device). Assemblies containing components from other manufacturers would have the NEMA type rating of the lowest rated device.
such as VersaMate VSQ/VBQ.
60 Amp Back Boxes are available in 1”, 1-1/4” and 1-1/2” conduit sizes. Size listed above is 1-1/4”. For other available sizes, change the BOLD “4” in either the assembly or box only number as follows: 3=1”, 4=1-1/4”, 5components.
Plug
Connector
Receptacle
plug (or connector) over a wide range of cable diameters (competitors often need two – requiring
additional sizing decisions).
• 60 Amp 600VAC/250VDC; 50-400 Hertz NEMA 3, 4, 4X
• PLUGS ONLY: Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D Class l, Zones 1 & 2, llB+H2, llA Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
Wire RangeR e g u l a r S t r a n d in g : # 6 - # 2 o r i g i n a l s t y l e o r “AT ” t y p e
E x t r a fl e x : # 6 - # 4 o r i g i n a l s t y l e o r “AT ” t y p e
F i l e No . E10757 Ce r t i fied F i l e No . LR111846
Origional or AT Terminals. See PR3 for
more information
FEATURES-SPECIFICATIONS
30 AMP PLUGS & CONNECTORS
GROUND STYLE CIRCUIT GROMMET
RANGE
CATALOG NUMBERPLUG CONNECTOR
ORIG. AT ORIG. AT
Style I2W2P .65 - 1.50 IN VP6275 VP6022 VPR6255 VPR60223W3P .65 - 1.50 IN VP6375 VP6033 VPR6355 VPR60334W4P .65 - 1.50 IN VP6475 VP6044 VPR6455 VPR6044
Style II2W3P .65 - 1.50 IN VP6385 VP6023 VPR6365 VPR60233W4P .65 - 1.50 IN VP6485 VP6034 VPR6465 VPR6034
MODIFICATIONS*CATALOG NUMBER DESCRIPTION
S39 Reverse service for receptacles, plugs & connectorsS37 Polarization for receptacles, plugs & connectors
* See page PR5 for more information on these options.
30 AMP RECEPTACLES & BACK BOXES
GROUNDSTYLE CIRCUIT
CATALOG NUMBERE TYPE C TYPE D TYPE RECEPTACLE ONLY
ORIG. AT ORIG. AT ORIG. AT ORIG. AT
Style I2W2P VR621E4 VR6022E4 VR621C4 VR6022C4 VR621D4 VR6022D4 VR621 VR60223W3P VR631E4 VR6033E4 VR631C4 VR6033C4 VR631D4 VR6033D4 VR631 VR60334W4P VR641E4 VR6044E4 VR641C4 VR6044C4 VR641D4 VR6044D4 VR641 VR6044
Style II2W3P VR632E4 VR6023E4 VR632C4 VR6023C4 VR632D4 VR6023D4 VR632 VR60233W4P VR642E4 VR6034E4 VR642C4 VR6034C4 VR642D4 VR6034D4 VR642 VR6034
Splice box only VRE46 VRE46 VRC46 VRC46 VRD46 VRD46 – –
Back Box Dimensions
VRDVRCVRE
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
60 AMP NEMA 4X METALLIC
VERSAMATE® SERIES
C
D
Receptacle
E
Connector
Plug
in accordance with instructions furnished with device). Assemblies containing components from other manufacturers would have the NEMA type rating of the lowest rated device.
such as VersaMate VSQ/VBQ.
60 Amp Back Boxes are available in 1”, 1-1/4” and 1-1/2” conduit sizes. Size listed above is 1-1/4”. For other available sizes, change the BOLD “4” in either the assembly or box only number as follows: 3=1”, 4=1-1/4”, 5components.
Plug
Connector
Receptacle
plug (or connector) over a wide range of cable diameters (competitors often need two – requiring
additional sizing decisions).
• 60 Amp 600VAC/250VDC; 50-400 Hertz NEMA 3, 4, 4X
• PLUGS ONLY: Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D Class l, Zones 1 & 2, llB+H2, llA Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
Wire RangeR e g u l a r S t r a n d in g : # 6 - # 2 o r i g i n a l s t y l e o r “AT ” t y p e
E x t r a fl e x : # 6 - # 4 o r i g i n a l s t y l e o r “AT ” t y p e
F i l e No . E10757 Ce r t i fied F i l e No . LR111846
Origional or AT Terminals. See PR3 for
more information
FEATURES-SPECIFICATIONS
60 AMP PLUGS & CONNECTORS
GROUND STYLE CIRCUIT GROMMET
RANGE
CATALOG NUMBERPLUG CONNECTOR
ORIG. AT ORIG. AT
Style I2W2P .65 - 1.50 IN VP6275 VP6022 VPR6255 VPR60223W3P .65 - 1.50 IN VP6375 VP6033 VPR6355 VPR60334W4P .65 - 1.50 IN VP6475 VP6044 VPR6455 VPR6044
Style II2W3P .65 - 1.50 IN VP6385 VP6023 VPR6365 VPR60233W4P .65 - 1.50 IN VP6485 VP6034 VPR6465 VPR6034
MODIFICATIONS*CATALOG NUMBER DESCRIPTION
S39 Reverse service for receptacles, plugs & connectorsS37 Polarization for receptacles, plugs & connectors
* See page PR5 for more information on these options.
60 AMP RECEPTACLES & BACK BOXES
GROUNDSTYLE CIRCUIT
CATALOG NUMBERE TYPE C TYPE D TYPE RECEPTACLE ONLY
ORIG. AT ORIG. AT ORIG. AT ORIG. AT
Style I2W2P VR621E4 VR6022E4 VR621C4 VR6022C4 VR621D4 VR6022D4 VR621 VR60223W3P VR631E4 VR6033E4 VR631C4 VR6033C4 VR631D4 VR6033D4 VR631 VR60334W4P VR641E4 VR6044E4 VR641C4 VR6044C4 VR641D4 VR6044D4 VR641 VR6044
Style II2W3P VR632E4 VR6023E4 VR632C4 VR6023C4 VR632D4 VR6023D4 VR632 VR60233W4P VR642E4 VR6034E4 VR642C4 VR6034C4 VR642D4 VR6034D4 VR642 VR6034
Splice box only VRE46 VRE46 VRC46 VRC46 VRD46 VRD46 – –
Back Box Dimensions
VRDVRCVRE
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
KILLARK RECEPTACLES
H A Z LO C
H A Z LO C
UGR / UGP INTERCHANGEABLE BLADE STYLE
ACCEPTOR® SERIES
The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeable with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with Crouse-Hinds® Ark-Gard®2 and Appleton® U-Line® plugs and receptacles in hazardous locations. No w available in GFCI versions. See pages R21-R22
How The Acceptor System Works
ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45°. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out.
Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings.
Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas.
Applications
• Petroleum Refineries, Chemical Plants• Wet/Damp/Corrosive Areas• Grain Elevators/Feed Mills
Features
• All external hardware is 316 stainless steel to provide low maintenance and long life
• Factory sealed chamber in UGR receptacle contains switch’s arcing components
• No additional external seals are required, except in Group B applications
• Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured
• Spring loaded receptacle cover closes when plug is removed to provide protection when not in use
• Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion
• Electrostatically applied and baked powder epoxy/polyester finish
PLUGACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system’s “turn to engage” feature locks in
listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.
plug and can be used to prevent accidental disengagement of critical equipment.
Plugs for use with type S, SO, ST or STO heavy duty cord.
Class I, Div. 1 & 2, Groups B, C, DClass I, Zones 1 & 2, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups F, GClass IIINEMA 3, 7 (B, C, D), 9 (F, G)
L i s t e d F i l e N o . E 9 10 4 9 a n d /o r E 5 3 6 6 0
C e r t i fi e d F i l e N o . L R 14 6 6 7
FEATURES-SPECIFICATIONS
Plugs Rated Group B when used with properly rated & installed receptacles. See next page.
VOLTAGE NEMACONFIGURATION
CATALOG NUMBERNEMA
CONFIGURATION
CATALOG NUMBER
15 AMP PLUG 15 AMP PLUG W/QUICK WIRING 20 AMP PLUG 20 AMP PLUG W/
QUICK WIRING
125VAC UGP-15231 UGP-15231QW UGP-20231 UGP-20231QW
250VAC UGP-15232 UGP-15232QW UGP-20232 UGP-20232QW
NEW!QW
QUICK WIRING PLUG
Quick Wiring Plug
• Single piece shell for fewer parts
• Transparent wiring entrance holes for easy conductor insertion
• Screws tighten from side with “full sized” screwdriver
• Insulator fits “one way”• Centered cable grip
1.51" 1.69"
2.55"
1/4"
45/8"
3"
UGPQW Plug
UGR Receptacle
WWW.HUBBELL-KILLARK.COMWWW.SCATTS.CO.UK
Stock held in the UK by Scattergood & Johnson Ltd. Available for next day delivery.