WIRING INSTRUCTIONS CR102 S ERIES C ABLE R EDUCTION B OX CR102 S ERIES C ABLE R EDUCTION B OX 1. Strip outer jacket of cable back 1¼ in. and remove all of the shielding. 2. Separate the internal wires from the shield and twist the shield. 3. Strip red and black insulation back ¼ in. 4. Locate the appropriate plug, identified by channel number, remove the plug and install the wires using a small flathead screwdriver. Push plug back into location. Orientation is as follows: a. Red insulated conductor wire is connected to (+). b. Black insulated conductor wire is connected to (-). c. Shield drain wire is connected to ground (GND). d. Depress selected position button on input terminal block to open terminal for respective wire. (May need mini flat head screwdriver). (-) Common Shield / Drain wire (+) Signal / Power 1¼” ¼” Visit our website to download the full manual for CR102 enclosures.

Upload: others

Post on 30-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Wiring instructionsCR102 SeRieS Cable ReduCtion boxCR102 SeRieS Cable ReduCtion box

    1. Strip outer jacket of cable back 1¼ in. and remove all of the shielding.

    2. Separate the internal wires from the shield and twist the shield.

    3. Strip red and black insulation back ¼ in.

    4. Locate the appropriate plug, identified by channel number, remove the plug and install the wires using a small flathead screwdriver. Push plug back into location.

    Orientation is as follows: a. Red insulated conductor wire is connected to (+). b. Black insulated conductor wire is connected to (-). c. Shield drain wire is connected to ground (GND). d. Depress selected position button on input terminal block to open terminal for respective wire. (May need mini flat head screwdriver).

    (-) Common

    Shield / Drain wire

    (+) Signal / Power1¼”

    ¼”

    Visit our website to download the full manual for CR102 enclosures.

    https://www.ctconline.com/epicor/MM-CR102-12_Rev_A.pdf

  • Wiring instructionsCR102 SeRieS Cable ReduCtion boxCR102 SeRieS Cable ReduCtion box

    ENSIONS E SHEET

    INPUTS OUTPUTS

    SENSOR INPUTS Red/White = Positive Black = Common Grey = Shield/Ground

    ENSIONS E SHEET

    INPUTS OUTPUTS

    SENSOR INPUTS Red/White = Positive Black = Common Grey = Shield/Ground

    Inputs Outputs

    Mw-Cr102-12/Rev A