craigie engineering sales and services ltd
TRANSCRIPT
T
Tel: +44 (0)7802 916577 E-mail: [email protected] Homepage: http://www.cess.co.uk
GTMM9484
New 279MW Siemens SGT5 - 4000F, 20 kV 50 Hz
Craigie Engineering Sales and Services Ltd
GTMM9484
New 279MW Siemens SGT5 - 4000F, 20 kV 50 Hz
GTMM9470
2 x 40MW Dual Fuel GE Frame 6C
in CCGT with 42 MW GE
Steam turbine with 11.5/154 kV
Transformers
(2005)
GTMM9491 New & unused 30MW
Siemens SGT700 Gas Turbine
Dual Fuel, 50 Hz, 11 kV (2011)
STGMM9376
2 x 500MW Coal-fired plant.
Recently refurbished with Parsons
Steam Turbines 50 Hz
(1976)
DEMM9474 14 x 16CM32 Caterpillar
HFO Diesels 7.68MW
11 kV 50 Hz = 100MW
(2005)
GTMM9360
Solar Titan 130 13.6MW, 11 kV
Unused Gas Turbine with HRSG
(2012)
New 2015
Map of UK Grid now available to
download or you can order paper copy at:
http://www.cess.co.u
k/specials/uk-grid-map/product/listing
FOR SALE : June 2015 – 50 Hz
These units are from our databases which list over 202,000MW of surplus power plant.
If you don’t see what you need drop us an e-mail: [email protected]
BO = Boiler CO = Compressor DE = Diesel Engines GT = Gas Turbine STG = Steam Turbines TF = Transformer WT = Wind Turbine
Specialists in the Valuation, Marketing, Sourcing and Relocation of Surplus Power Plant & Auxiliary Equipment
T
Tel: +44 (0)7802 916577 E-mail: [email protected] Homepage: http://www.cess.co.uk
GTMM9612
105MW
11.5KV 50 Hz GE LMS100PA
Gas Fuel Gas Turbine
(2013)
STGMM9378-9380 Various
3MW, 6MW +12MW biomass, wood-
waste and coal-fired Boilers &
Steam Turbine plants (2003)
Craigie Engineering Sales and Services Ltd
GTMM9499
GTMM9499 38MW
diesel/gas/naphtha GE Frame 6B in
CCGT with Siemens 37MW Steam Turbine
& 11/33 kV T/F
(1999)
MM1409179,
4 X 135kV
Circuit Breakers €295,000 for all 4
Ex-Works
As-Is, Where-Is
GTMM9367
GE Frame 6B & LM2500 Gas
Turbines in CCGT with 33MW
Siemens Steam Turbine to give
94MW
STGMM9388
2 X Alstom CFB coal-fired
101 Bar Boilers & 151MW,
5.75/132kV Siemens-Stal steam turbine
(2001)
GTMM9126
2 x GE Frame 6B 39MW 11 kV
gas fuel (dismantled 2010)
Barge-mounted 2015 (1993)
GTMM9400
2 X 125MW
GE Frame 9E 50 Hz, dual fuel
Gas Turbines (2013)
STGMM9318-9 2 X Ansaldo 12.5-
15MW 11 kV Steam Turbines
in CCGT 70 Bar 500 C
See GTMM9280-81 Frame 6B (1994-8)
GTMM9164
New Allison 501KB7
Gas Turbine 11 kV (2012)
GTMM9414
2 x unused 250MW GE Frame 9FA gas fuel 15.75/400 kV in
CCGT with HRSG’s & 289MW
Steam Turbine 2011
BOMM956
2 x 65 Bar, 480 C 176,000 lbs/hr
Standard Fasel Oil/gas-fired
standby boilers <3000 hours
(1999)
June 2015
2014
T
Tel: +44 (0)7802 916577 E-mail: [email protected] Homepage: http://www.cess.co.uk
GTMM9298
70MW 50 Hz GE Frame 6FA
gas turbine gen set + 32MW Pignone steam turbine generator with 11.5/132 kV T/F
(1998)
Craigie Engineering Sales and Services Ltd
GTMM9188
70MW GE Frame 6FA CCGT
with 53MW Ansaldo Steam Turbine
+ 11/132 kV T/F (1998)
STGMM9402 New & Unused
Toshiba 215MW, 18 kV, 50 Hz
Steam Turbine Gen set 104 Bar
Condensing (2009)
GTMM9622
Zero houred Pratt & Whitney dual fuel 50+MW
Twinpac units 3 x FT4C-1D 4 x FT4C-3F 50 Hz, 11 kV
(1977-80)
DEMM9486
4 x Cat G3613
6.6 kV 3655kW
35044-37210 hrs (2000)
STGMM9333 4.7MW Triveni
extraction / condensing
Steam turbine with 2 unused wood/biomass Boilers 62 Bar
480C (2009)
DEMM7058 4 x 22MW
50Hz, 11kV, Pielstick 18PC4-2B
HFO/Diesel Generator Sets, +/- 20,000 hrs,
(2000-2002)
CESS has access
to a fleet of 8 x 250+MW
GE Frame 9FA Units
GTMM9470
2 x GE Frame 6C Gas Turbines in
CCGT with 40 MW Steam Turbine
2005
GTMM9296
Advanced Order 3 x GE PGT LM2500+G4
SAC Compressor Drives + 2 x Nuovo
Pignone Compressors
2BCL406/C - 350 bar (2013)
GTMM9333
21.9MW 50 Hz GE LM2500PE
Gas Turbine 6.3 kV CCGT with
4.9MW Alstom steam turbine 120,000 hours
(1994)
June 2015
T
Tel: +44 (0)7802 916577 E-mail: [email protected] Homepage: http://www.cess.co.uk
ALTMM936
New & Unused 1100kVA EWE 6-pole, 400V 1000 RPM
(2012)
Combustion, Energy and Steam Specialists Ltd.
STGMM9353
STGMM9353
6MW, 50 Hz, Thermodyne Boiler & Bellis-Toyi Denki
Biomass Plant
(2000)
CESS will be present
at O&M and Lifecycle Management
Strategies for CCGT Power Plants, Asia-Pacific:
http://goo.gl/CMBXrX
http://goo.gl/1HZhYy
TFMM967
5 X 80 MVA ONAN 60%, ONAF 100%) 110kV/11kV
of-circuit tap changers +/- 2 x 2.5%
Ynd11 (2014)
DEMM9447 New & unused 3.4MW 50 Hz Huatai Fujian
HTP3400 1,000 RPM
Diesel Generator
(2014)
STGMM9379
12 MW KALUGA
Biomass/Coal fired Power Plant
(2003)
TFMM966 2 X 80 MVA ONAN 60%, ONAF 100%) 220kV/11kV off-circuit
tap changers +/- 2 x 2.5%
Ynd11 (2014)
DEMM9478
DEMM9478 4 x 47.5MW,
Hyundai 12K90MC-S 50Hz, 11/132kV,
HFO/Diesel Gen Sets,
+/- 90,000 hrs, (2000)
STGMM9190
Blohm & Voss model KR 35/50/2
1345kW, 41 bar, 450 C
Cond 0.16 barA Steam 6.23 T/hr
(1988)
STGMM9345 6.6MW, 50 Hz,
11 kV, 44 /3.5 bar 430 C Siemens Back Pressure/
Extraction @ 11 bar Steam Turbine
(1996)
DEMM9353A
4 x 6.587MW, 50 Hz, 11 kV Wartsila Vasa
18V32LN Diesel/HFO
Generator Sets
(2001)
DEMM9359
7.25MW, 50 Hz, 6 kV Warstlia 18V32
Diesel/HFO Generator Set
(1992)
June 2015
T
DEMM7134
4 x 3.2 MW HFO Diesels, 50 Hz, Niigata Pielstick
16V25HS, (38000-45000 hrs)
(1996)
DEMM7135
1 x 1,200 kW, 50 Hz, HFO Diesel, Niigata
Pielstick 6L26HS 3,384 hours,
(1996)
Craigie Engineering Sales and Services Ltd
.
DEMM7128
3 x 2.3 MW 6.6 kV, 50 Hz Caterpillar
8MC25, HFO diesels from cancelled order, 750 RPM, new with
full Cat warranty (2007)
DEMM7064
2 x Deutz 3,535 kW,
50 Hz, 6.6 kV Gas Engine Model
TBG 632V16 with 6.5 Bar steam
and hot water boilers, 1600/5300 hours only
(2000)
DEMM7156
2 x 5.8 MW, 50 Hz, 6.6 kV, Pielstick 16-PC2V
Diesel Generators, HFO, 500 RPM,
(1984)
DEMM7147
8 x 9.5 MW HFO Diesels, 50 Hz, 10.5 kV Niigata Pielstick 18PC2-
6/2V, 500 RPM, 37000-44500
hrs, (1993)
DEMM7141
20 MW MAN B&W
9L58/64 HFO Diesel, 50 Hz, 11 kV, 428
RPM, operated until
November (2004)
DEMM7143
2 x 10,560 kW Diesels, 50 Hz MAN B&W
18V40/45, 500 RPM, 93000-96250 hrs,
(1993)
June 2015
14201421Aug
2013
I have now been in this business for over 37 years and am 63 next month. I am looking to gradually reduce my investment in the Company which has to date reached a fairly
impressive total (impresses the hell out of me anyway) of over 103,513MW (valued at over US$8 Billion) of valuation experience in the past 19 years. These appraisals have included:
744 gas turbines (including Allison, Rolls Royce, GE, Solar, Pratt & Whitney, Fiat, Ruston, GEC, Alstom, Westinghouse, Mitsubishi, Siemens & ABB/Alstom)
292 steam turbines (including AEG, ABB, Ansaldo, Blohm & Voss, Elliott, Fuji, GE, Hitachi, Westinghouse, Siemens, Terry, Mitsubishi, Parsons, Stal, Allen, KKK, Peter Brotherhood, Daniel
Adamson, AEI/EE, Worthington, Zamec & Alstom) 687 diesels (including Niigata, Pielstick, Crossley, Colt, Polar, MTU, MWM Deutz, Mirrlees,
Enterprise-De Laval, Superior, MAN/B&W, Wartsila/NSD, Ruston, Cummins, Caterpillar/MAK, Rolls Royce/Ulstein
Craigie Engineering Sales & Services Ltd (CESS) have to date been instrumental in the sale of 81 gas turbines (total 2,895MW), 37 steam turbines (1,362MW), 108 diesel/gas engines (277MW), and 45
transformers (total 616 MVA). Worth over $197M CESS database includes 1,810 different gas turbines, 2,587 diesels, & 2,100 steam turbines.
The project database has 24,515 enquiries since 1995 in 139 countries. 42% of these came from existing clients; 24% were from our Website or Internet; 18% were from as referrals from existing
clients; 12% were from advertising or marketing, and 4% were from site visits or trade shows The Gas/Steam Turbines/Diesels databases and Project files were independently appraised as being
worth £450,000 in 2007 when they contained 4,500 different generators (now 6,500) and 23,000 customers, so we have provisionally assessed their value now at US$ 250,000 each.
Our e-mail list has 38,000+ e-mail addresses and I have I have 4,603 contacts on Linked In http://www.linkedin.com/pub/mike-craigie/6/2b1/126 I have 1,470 members in my ‘Linked In’ Valuation Group.
https://www.linkedin.com/groups?viewMembers=&gid=3697918&sik=1398451416864
We are now planning to open an office in Subic or KL and looking to bring in new investors/shareholders whose regional support
and/or expertise can enhance our global reputation.
CESS Project Experience
Valuation Marketing Sourcing Sale
Gas Turbines Number 744 399 173 81
Capacity (MW) 46915 23842 6960 2895
Steam Turbines Number 292 208 59 37
Capacity (MW) 34049 20914.5 8646 1362
Diesel Engines Number 687 372 209 110
Capacity (MW) 3325.5 2036.4 856.4 280.4
Barges Number 41 24 91 6
Capacity (MW) 2466 1441 5452 354
Transformers Number 307 198 84 45
Capacity (MW) 16757.9 7192.4 1134.4 616.4
HDHDHDHDHDHDHDJFJHFJFJFJFJJFJJGFJ
Tel: +44 (0)7802 916577 E-mail: [email protected] Homepage: http://www.cess.co.uk
Craigie Engineering Sales and Services Ltd
2014 year end figures:
This past year we have been involved in the appraisal of 12,842MW
Download CESS Valuation Experience: http://www.cess.co.uk/images/Experience/CESS2Valuation.pdf
Craigie Engineering Sales & Services Ltd (CESS) have to date been instrumental in the sale of 81 gas turbines (total 2,895MW), 37 steam turbines (1,362MW), 110 diesel/gas engines
(280MW), and 45 transformers (total 616 MVA).
CESS has now reached an impressive total of over 103,993MW (>$8.1 Billion) of valuation experience in the past 16 years and these valuations have included:
744 gas turbines (including Allison, Rolls Royce, GE, Solar, Pratt & Whitney, Fiat, Ruston, GEC Alstom, Westinghouse, Mitsubishi, Siemens & ABB/Alstom)
295 steam turbines (including AEG, ABB, Ansaldo, Blohm & Voss, Elliott, Fuji, GE, Hitachi, Westinghouse, Siemens, Terry, Mitsubishi, Parsons, Stal, Allen, KKK, Peter Brotherhood, Daniel Adamson, AEI/EE, Worthington, Zamec & Alstom)
687 diesels (including Niigata, Pielstick, Crossley, Colt, Polar, MTU, MWM Deutz, Mirrlees, Enterprise-De Laval, Superior, MAN/B&W, Wartsila/NSD, Ruston, Cummins, Caterpillar/MAK, Rolls Royce/Ulstein/Allen)
170 312 285 38
1146976 905
26452572
1457
2687
54885252
6628
783387018863
10108
12842
0
2000
4000
6000
8000
10000
12000
14000
19961997199819992000200120022003200420052006200720082009201020112012201320142015
S…
June 2015
Tel: +44 (0)7802 916577 E-mail: [email protected] Homepage: http://www.cess.co.uk
Craigie Engineering Sales and Services Ltd
CESS is also available to undertake the decommissioning, dismantling, relocation and re-installation and commissioning of such plants and have extensive experience in this field.
http://www.cess.co.uk/reference.html
This last year we have listed: a. 486 diesels totalling 1,112MW (average 2.3MW) b. 192 gas turbines totalling 9,394MW (average 29MW) c. 138 steam turbines totalling 4,413MW (average 31.97MW).
For further info: Mike Craigie
Craigie Engineering Sales & Services Ltd Energy House, 45 Hamnavoe Stromness, Orkney Islands, KW16 3JQ Tel: +44-7802 916 577
e-mail: [email protected] Website: www.cess.co.uk
June 2015