MAIN GLU-LAM BEAMS 200X600MM SPANING THE ENTIRE ROOF WHICH STRAP TO THE CLT VIERENDEEL WALL THAT TIE BACK TO THE MAIN CLT AUDITORIUM STRUCTURE SERIES OF I-JOISTS SPANING IN BETWEEN THE BEAMS AND THE WALLS AT 600 CTRS. BESPOKE SKYLIGHT WITH SCHUCO TRANSOMS. HARDENED LAMINATED GLASS IS TO BE MASTICLY SEALED WITH STRUCTURAL MASTIC SEAL AS PER MANUFACTURERS SPECIFICATION AT HORIZONTAL AXIS TO ALLOW WATER RUN OFF. 200MM CLT VIERENDEEL WALL 15MM OSB TO BE FIXED ON TOP OF BEAMS TO CREATE LEVEL PLANE TO LAY SPECIFIED TAPERED PIR INSULATION OVER AT FALLS 1:60 250MM GGBS CONCRETE STAIR CORE CORE BESPOKE RIB CAGE CORNER SYSTEM COMPOSING OF A SERIES OF GLUE-LAM BEAMS WEBBED TOGETHER DESIGNED FOR THE SOLE PURPOSE OF AIDING TO COUNTERACT BENDING MOMENT AT THE FAR REACH OF THE CONTILEVERED VIERINDEEL WALL STRUCTURES. 200MM CLT VIERENDEEL WALL TO BE STRAPPED BACK TO 250MM CLT AUDITORIUM WALL WITH GALVINISED STEEL BRACKETS AND BESPOKE GALVINISED STEEL SHELVING BRACKETS CUSTOM CUT 200MM CLT FLOOR SLAB MEMBER THAT SIT ABOVE POST AND BEAM STRUCTURE AT FOYER 150MM CONCRETE KICKERS ARE TO BE CAST WHERE CLT WALLS / BLU-LAM POSTS AREA TO BE ERECTED. 200MM CLT ROOF PANELS TO BE BRACKETED DOWN TO CLT WALLS. THICKNESS SHOWN INCLUDES INSULATION Nabil Ghnewa C13470042 DT175 02 2017 Naul Village Dublin 53.586°N 6.290°W LEGEND GENERAL DESIGN NOTES KEY PLAN 08/01/2018 21:43:17 1 : 500 DT175 TDS Music Centre Project STRUCTURAL MATRIX A115 NABIL GHNEWA JIM ROCHE JIM ROCHE JIM ROCHE STRUCTURAL MATRIX BAUDER BIODIVERSE ROOF PRODUCT SPECIFICATION POSI GLAZE FRAMELESS GLASS BALUSTRADE GUIDE KLH CLT SPECIFICATION GUIDE FIRE PIPE COLLAR B150 GUTEX MULTITHERM ROCK PANNEL INSTALLATION GUIDE INSULATED SUSPENDED CEILING RHEINZINK REVEAL PANNEL GUIDE CLT TO BE FITTED TO MANUFACTURERS SPECIFICATION UTILISING GLVINIZED STEEL BRACKETS. EACH PANNEL RESTING ON CONCRETE KICKER TO HAVE LAYER ON DPC UNDERNEATH TO PROVENT RISING DAMP FROM ENTERING THE STRUCTURE. GUTEX WALL WOOD FIBRE BOARD FOLLOWING ON-CENTRE DISTANCES APPLY: 40 MM BOARD THICKNESS MAX. ON-CENTRE IS 62.5 CM 60 - 200 MM BOARD THICKNESS MAX. ON-CENTRE IS 83.5 CM ALL MEMBRANES ARE TO BE TAPED AND PIPES THAT PUNCTURE THROUGH THE MEMBRANES ARE TO BE SEALED WITH MANUFACTURERS SUPPLIED TAPE TO ENSURE CONTINUITY AIR AND WATER TIGHTNESS AT ROOF LEVEL. ALL PERFERATIONS THROUGH VAPOUR PERMEABLE MEMBRANE ARE TO BE TAPED TO ENSURE INTEGRITY OF MEMBRANE AND VAPOUR DIFFUSION RATE. WINDOW FRAME TO HAVE PLASTIC THERMAL BREAK PACKER BETWEEN ALUMINIUM FRAME AND CLT WALL TO PREVENT POTENCIAL CONDINSATION OCCURENCE BETWEEN BOTH MATERIALS WITH WIND PROOF TAPE TO BE APPLIED TO PREVENT THERMAL BRIDGING. TAPRED PIR IS TO BE INTALLED TO MANUFACTURERS SPECIFICATION AND AT A FALL OF 1:80. SUSPENDED ACOUSTIC CEILING PANNELS ARE TO BE HUNG LEVEL IN ACCOURDANCE TO MANUFACTURERS SPECIFICATION. FIRE COLLARS ARE REQUIRED FOR EVERY PIPE THAT MAY PENETRATE A FLOOR OR WALL. FIRE COLLARS SUPPLIED WITH DIFFERENT SIZES DEPENDING ON PIPE SIZE ARE TO FITTED TO MANUFACURERS SPECIFICATION. ALUMINIUM RAIN WATER PIPES THAT ARE TAKEN THROUGH THE BUILDING MUST BE INSULATED AND HIDDEN BEHIND THIN CLT WALL TO MAINTAIN CONTINUITY IN THE AESTHETIC EFFECT AND CONTRIBUTE TO THERMAL MASS EFFECT. WHEN INSTALLING ROCKPANEL BOARDS ON ALUMINIUM LOAD-BEARING SECTIONS, FXED POINTS, SLOTTED HOLES AND MOVING POINTS SHOULD BE APPLIED. BY APPLICATIONS OF FXED POINTS AND MOVING POINTS THE FXED POINTS SHOULD BE PRE-DRILLED WITH Ø 5.2 MM, SLOTTED POINTS Ø 5,2 X 8 MM AND THE MOVING POINTS WITH Ø 8 MM. THE SLIDING ATTACHMENT MUST BE DONE WITH A ‘RIVET SPACER’ SO THAT THE ATTACHMENT CAN MOVE EASILY. INSTEAD OF DRILLING FX POINTS AND SLOTTED HOLES ALSO FX-POINT SLEEVES AND SIDE SLEEVES CAN BE USED TO ACHIEVE THE REQUIRED HOLES. CONTACT THE ROCKPANEL GROUP FOR MORE INFORMATION. PURE VISTA OR (E/A) GLASS BALUSTRADE . THE MEGAGRIP BASE RAIL SHOULD BE PLACED ONTO ITS DESIGNATED POSITION AND THE HOLES MARKED ON THE SUBSTRATE FOR DRILLING. ONCE THE SHOE IS LEVEL INSERT THE FIXINGS AND TIGHTENED UP TO MAKE THE CHANNEL RIGID. THE FIXINGS MUST BE TIGHTENED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. M12 COUNTERSUNK BOLTS MUST BE USED. N S E W N REVISED

Upload: others

Post on 05-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: C:UsersmarkoDesktopDT175-03 GHNEWA N C13470042 … · 2019. 2. 20. · vierendeel wall that tie back to the main clt auditorium structure series of i-joists spaning in between the

MAIN GLU-LAM BEAMS 200X600MM SPANING THE ENTIRE ROOF WHICH STRAP TO THE CLT VIERENDEEL WALL THAT TIE BACK TO THE MAIN CLT AUDITORIUM STRUCTURE

SERIES OF I-JOISTS SPANING IN BETWEENTHE BEAMS AND THE WALLS AT 600 CTRS.

BESPOKE SKYLIGHT WITH SCHUCO TRANSOMS. HARDENED LAMINATEDGLASS IS TO BE MASTICLY SEALED WITH STRUCTURAL MASTIC SEAL ASPER MANUFACTURERS SPECIFICATION AT HORIZONTAL AXIS TO ALLOW WATER RUNOFF.

200MM CLT VIERENDEEL WALL

15MM OSB TO BE FIXED ON TOP OF BEAMS TOCREATE LEVEL PLANE TO LAY SPECIFIED TAPEREDPIR INSULATION OVER AT FALLS 1:60

250MM GGBS CONCRETESTAIR CORE CORE

BESPOKE RIB CAGE CORNER SYSTEM COMPOSING OF A SERIES OF GLUE-LAM BEAMS WEBBED TOGETHER DESIGNEDFOR THE SOLE PURPOSE OF AIDING TO COUNTERACTBENDING MOMENT AT THE FAR REACH OF THE CONTILEVEREDVIERINDEEL WALL STRUCTURES.

200MM CLT VIERENDEEL WALLTO BE STRAPPED BACK TO 250MM CLT AUDITORIUM WALLWITH GALVINISED STEEL BRACKETS AND BESPOKE GALVINISED STEEL SHELVING BRACKETS

CUSTOM CUT 200MM CLT FLOOR SLAB MEMBERTHAT SIT ABOVE POST AND BEAM STRUCTUREAT FOYER

150MM CONCRETE KICKERS ARE TO BE CAST WHERE CLT WALLS / BLU-LAM POSTSAREA TO BE ERECTED.

200MM CLT ROOF PANELS TO BEBRACKETED DOWN TO CLT WALLS.THICKNESS SHOWN INCLUDES INSULATION

Checked byDesigned By Approved By - Date

Project Address/Coordinates

Scale

Project Name

Sheet Name

Rev No Rev Note Date/Time North Checked

1 2 3 4 5 6 7 8 9 10 11 12 13

1 2 3 4 5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

Nabil Ghnewa C13470042 DT175 02 2017

Sheet Number

Naul Village Dublin53.586°N 6.290°W

14

LEGEND

GENERAL DESIGN NOTES

KEY PLAN

08/01/2018 21:43:17

1 : 500

DT175 TDS MusicCentre Project

STRUCTURAL MATRIX

A115

NABIL GHNEWA JIM ROCHE JIM ROCHE

JIM ROCHE

STRUCTURAL MATRIX

BAUDER BIODIVERSE ROOFPRODUCT SPECIFICATION

POSI GLAZE FRAMELESS GLASSBALUSTRADE GUIDE

KLH CLT SPECIFICATION GUIDE

FIRE PIPE COLLARB150

GUTEX MULTITHERM

ROCK PANNEL INSTALLATION GUIDE

INSULATED SUSPENDED CEILING

RHEINZINK REVEAL PANNEL GUIDE

CLT TO BE FITTED TO MANUFACTURERS SPECIFICATION UTILISING GLVINIZED STEEL BRACKETS. EACH PANNEL RESTING ON CONCRETEKICKER TO HAVE LAYER ON DPC UNDERNEATH TO PROVENT RISING DAMP FROMENTERING THE STRUCTURE.

GUTEX WALL WOOD FIBRE BOARD

FOLLOWING ON-CENTRE DISTANCES APPLY:40 MM BOARD THICKNESS → MAX. ON-CENTRE IS 62.5 CM60 - 200 MM BOARD THICKNESS → MAX. ON-CENTRE IS 83.5 CM

ALL MEMBRANES ARE TO BE TAPED AND PIPES THAT PUNCTURE THROUGHTHE MEMBRANES ARE TO BE SEALED WITH MANUFACTURERS SUPPLIEDTAPE TO ENSURE CONTINUITY AIR AND WATER TIGHTNESS AT ROOF LEVEL.

ALL PERFERATIONS THROUGH VAPOUR PERMEABLE MEMBRANE ARE TOBE TAPED TO ENSURE INTEGRITY OF MEMBRANE AND VAPOUR DIFFUSION RATE.

WINDOW FRAME TO HAVE PLASTIC THERMAL BREAK PACKER BETWEEN ALUMINIUM FRAME AND CLT WALL TO PREVENT POTENCIAL CONDINSATIONOCCURENCE BETWEEN BOTH MATERIALS WITH WIND PROOF TAPE TO BE APPLIEDTO PREVENT THERMAL BRIDGING.

TAPRED PIR IS TO BE INTALLED TO MANUFACTURERS SPECIFICATION AND AT A FALLOF 1:80.

SUSPENDED ACOUSTIC CEILING PANNELS ARE TO BE HUNG LEVEL IN ACCOURDANCETO MANUFACTURERS SPECIFICATION.

FIRE COLLARS ARE REQUIRED FOR EVERY PIPE THAT MAY PENETRATE A FLOOROR WALL. FIRE COLLARS SUPPLIED WITH DIFFERENT SIZES DEPENDING ON PIPESIZE ARE TO FITTED TO MANUFACURERS SPECIFICATION.

ALUMINIUM RAIN WATER PIPES THAT ARE TAKEN THROUGH THE BUILDING MUST BE INSULATED AND HIDDEN BEHIND THIN CLT WALL TO MAINTAIN CONTINUITYIN THE AESTHETIC EFFECT AND CONTRIBUTE TO THERMAL MASS EFFECT.

WHEN INSTALLING ROCKPANEL BOARDS ONALUMINIUM LOAD-BEARING SECTIONS, FXED POINTS,SLOTTED HOLES AND MOVING POINTS SHOULD BE APPLIED. BY APPLICATIONSOF FXED POINTS AND MOVING POINTS THE FXED POINTS SHOULD BEPRE-DRILLED WITH Ø 5.2 MM, SLOTTED POINTS Ø 5,2 X 8 MM AND THEMOVING POINTS WITH Ø 8 MM. THE SLIDING ATTACHMENT MUST BE DONEWITH A ‘RIVET SPACER’ SO THAT THE ATTACHMENT CAN MOVE EASILY.INSTEAD OF DRILLING FX POINTS AND SLOTTED HOLES ALSO FX-POINT SLEEVESAND SIDE SLEEVES CAN BE USED TO ACHIEVE THE REQUIRED HOLES.CONTACT THE ROCKPANEL GROUP FOR MORE INFORMATION.

PURE VISTA OR (E/A) GLASS BALUSTRADE .

THE MEGAGRIP BASE RAIL SHOULD BE PLACED ONTO ITSDESIGNATED POSITION AND THE HOLES MARKED ON THESUBSTRATE FOR DRILLING. ONCE THE SHOE IS LEVEL INSERTTHE FIXINGS AND TIGHTENED UP TO MAKE THE CHANNELRIGID. THE FIXINGS MUST BE TIGHTENED IN ACCORDANCEWITH THE MANUFACTURERS INSTRUCTIONS.M12 COUNTERSUNK BOLTS MUST BE USED.

N

S

E

W

N

REVISED