DATA CENTER COOLING CONDENSERS / EVAPORATORS / FLUID HEAT EXCHANGERS www.superradiatorcoils.com Phoenix, AZ (800) 899-2645 Chaska, MN (800) 394-2645 Richmond, VA (800) 229-2645 Tube Diameters: 5mm, 5/16", 3/8", ", 5/8", 7/8", 1" Tube Materials for Construction: Aluminum, Copper, Cupro-Nickel & Stainless Steel Fin Materials for Construction: Aluminum, Copper, Cupro-Nickel & Stainless Steel Fin Enhancements: Flat, Embossed, Corrugated Wave, Sine Wave, X-Fin (Louvered) Materials of Construction Applications CRAH (Computer Room Air Handlers) CRAC (Computer Room Air Conditioning) Data Centers Hybrid, Free Cooling, Submerge Systems Liquid Cooling, Air Cooling , Refrigerants Cooling, CO 2 Racks, Rows & Rooms Supercomputers Products Condensers Dielectric Cooling Coils Evaporators Glycol Cooling Coils Water Cooing Coils Water Cooling Coil Glycol Cooling Coils Evaporators Quality Assured: 100% of our Coils are Leak Tested for your Confidence

Upload: others

Post on 13-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DATA CENTER COOLING - superradiatorcoils.com · Cooling now accounts for an average of 30% of a data center’s OPEX and CAPEX. Thermal optimization is a fundamental requirement across

DATA CENTER COOLINGCONDENSERS / EVAPORATORS / FLUID HEAT EXCHANGERS

www.superradiatorcoils.com

Phoenix, AZ (800) 899-2645

Chaska, MN(800) 394-2645

Richmond, VA(800) 229-2645

Tube Diameters: 5mm, 5/16", 3/8", 1/2", 5/8", 7/8", 1"

Tube Materials for Construction: Aluminum, Copper, Cupro-Nickel

& Stainless Steel

Fin Materials for Construction: Aluminum, Copper, Cupro-Nickel &

Stainless Steel

Fin Enhancements: Flat, Embossed, Corrugated Wave, Sine Wave,

X-Fin (Louvered)

Materials of Construction

ApplicationsCRAH (Computer Room Air Handlers)

CRAC (Computer Room Air Conditioning)

Data Centers

Hybrid, Free Cooling, Submerge Systems

Liquid Cooling, Air Cooling , Refrigerants Cooling, CO2

Racks, Rows & Rooms

Supercomputers

ProductsCondensers

Dielectric Cooling Coils

Evaporators

Glycol Cooling Coils

Water Cooing Coils

Water Cooling Coil Glycol Cooling Coils

Evaporators

Quality Assured: 100% of our Coils are Leak Tested for your Confidence

Page 2: DATA CENTER COOLING - superradiatorcoils.com · Cooling now accounts for an average of 30% of a data center’s OPEX and CAPEX. Thermal optimization is a fundamental requirement across

Wind Tunnel Test Lab

Capabilities

%

Air temperature from 23°F to 140°F (-5°C to 60°C) Entering Water temperatures up to 180°F (82°C)

Entering Glycol temperatures range from 20°F to 200°F

(-6°C to 93°C)

MultiTherm Oil temperatures up to 400°F (204°C)

Humidity from 20% to 95%

Separate fluid testing loops for: Water, Glycol, Oil, Steam,

Refrigerants, and Other Fluids

Airflow from 100 to 8,500 cubic feet per minute

(0.05 – 4.00 m3/s)

Steam pressures from 15 to 150 psi

Steam temperatures from 250°F to 366°F

(121°C to 185°C)

Energy Costs Continue to Rise & Thermal Optimization is a Top PriorityCooling now accounts for an average of 30% of a data center’s OPEX and CAPEX. Thermal optimization is a fundamental requirement across the

industry and Super Radiator Coils is fully equipped to help.

Located in our Richmond, VA facility, our Wind Tunnel Test Lab can handle a wide range of application tests including airflow, temperature stability,

humidity and fluid testing loops for all mediums. We welcome you to use our facility to prove new concepts, technology and systems, verify coil

performance and most of all build confidence.

Energy Efficiency Testing & Capabilities

Certifications

CRN

All tests approved and directed by Dr. Jian Yu

Register to use our Enterprise Selection Software App: https://apps.superradiatorcoils.com