Visit www.panduit.com/datacenter for complete data center solutions with detailed part information. Data Center Power Infrastructure Solutions Don’t let a simple power connection take down your network. Clean and reliable power is key to data center performance and uptime. PANDUIT provides solutions for all of the critical connections from the utility transformer through the network equipment to protect your data center investment. PANDUIT ® P AN-LUG Copper Compression Lugs and Splices are UL Listed, CSA Certified, and are the first and only connectors to meet Network Equipment-Building Systems (NEBS) Level 3 Requirements as tested by Telcordia Technologies. NEBS Level 3 is a set of stringent tests that subject components to extreme environmental conditions. Connectors that meet these requirements help ensure dependable performance over the life of the installation. PANDUIT offers the “Success Depends on the Crimp” training program to help installers achieve a reliable, safe termination to reduce your risk in the data center power infrastructure. Proven Reliability for Mission Critical Applications

Upload: lamnguyet

Post on 17-Mar-2018

242 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: Data Center Power Infrastructure Solutions Center Power Infrastructure... · Visit for complete data center solutions with detailed part information. Data Center Power Infrastructure

Visit www.panduit.com/datacenter for complete data center solutions with detailed part information.

Data Center Power Infrastructure Solutions

Don’t let a simple power connection take down your network. Clean and reliable power is key to data center performanceand uptime. PANDUIT provides solutions for all of the critical connections from the utility transformer through the networkequipment to protect your data center investment.

PANDUIT ®PAN-LUG™Copper Compression Lugs and Splices are UL Listed, CSA Certified, and are the first and onlyconnectors to meet Network Equipment-Building Systems (NEBS) Level 3 Requirements as tested by Telcordia Technologies.NEBS Level 3 is a set of stringent tests that subject components to extreme environmental conditions. Connectors that meetthese requirements help ensure dependable performance over the life of the installation.

PANDUIT offers the “Success Depends on the Crimp” training program to help installers achieve a reliable, safe termination to reduce your risk in the data center power infrastructure.

Proven Reliability for Mission Critical Applications

Page 2: Data Center Power Infrastructure Solutions Center Power Infrastructure... · Visit for complete data center solutions with detailed part information. Data Center Power Infrastructure

1.

2.

3.

U t i l i t y a n d G e n e r a t o r S o u r c e sMaximize uptime and protect network equipment and personnel in your data center by ensuring a reliable and safe power infrastructurewith solutions from PANDUIT.

2

The utility transformer provides the main power to the system. In the event of an interruption, the backup generator provides power.

PAN-LUG™ Copper

Compression Lugs for

Code and Flex Conductor

Labeling Systems

Safety Solutions

Cable Ties

Abrasion

Protection

Lockout/

Tagout

1

2

3

3

4

5

45

6

BackupGenerator

UtilityTransformer

To AC Service Entrance

To Automatic Transfer Switch(switchgear)

Power infrastructure should follow NEC standards/national/regional/local electrical codes.

DUCTSEAL

4.

5.

6.

Page 3: Data Center Power Infrastructure Solutions Center Power Infrastructure... · Visit for complete data center solutions with detailed part information. Data Center Power Infrastructure

3

S e r v i c e E n t r a n c eMaximize uptime and protect network equipment and personnel in your data center by ensuring a reliable and safe power infrastructurewith solutions from PANDUIT.

The automatic transfer switch (switchgear) is connected to the utility and generator sources, and is routed to the uninterruptible power supply (UPS).The UPS includes backup batteries and supplies power to the electrical distribution system which allows time for the backup generator to start.

Labeling Systems

Safety Solutions

Cable Ties

Abrasion

Protection

1

1

111

2

22

2

3

3

4

44

5

5

AC ServiceEntrance

AutomaticTransfer Switch(switchgear)

Batteries

To Batteries

To Power Distribution Unit (PDU)

Telecommunications Bonding Backbone (TBB) To Non

UPS Loads

Power infrastructure should follow NEC standards/national/regional/local electrical codes.

DUCTSEAL

1.

2.

3.

4.

5.

6. STRUCTUREDGROUND™

Grounding

System

PAN-LUG™ Copper

Compression Lugs for

Code and Flex Conductor

1

6

UninterruptiblePower Supply (UPS)

Page 4: Data Center Power Infrastructure Solutions Center Power Infrastructure... · Visit for complete data center solutions with detailed part information. Data Center Power Infrastructure

1.

2.

3.

4.

5.

6.Safety Solutions

Cable Ties

STRUCTUREDGROUND™

Grounding

System

www.panduit.com

For more information or to request a catalog800-777-3300

[email protected]

©2008 PANDUIT CorpALL RIGHTS RESERVED.

Printed in the U.S.A.SA-PCFL01

4/2008

D a t a C e n t e r R a i s e d F l o o rMaximize uptime and protect network equipment and personnel in your data center by ensuring a reliable and safe power infrastructurewith solutions from PANDUIT.

PAN-LUG™ Copper

Compression Lugs for

Code and Flex Conductor

1

5

AC Panel

1

2

2

2

6

3

4

PowerDistributionUnit (PDU)

FromUninterruptiblePower Supply (UPS)

Network Equipment Cabinets

Power infrastructure should follow NEC standards/national/regional/local electrical codes.

For a copy of PANDUIT product warranties, log on to www.panduit.com/warranty

Power Distribution Units (PDUs) provide power to AC panels. AC panels provide power to network equipment cabinets.

Labeling Systems Abrasion Protection

6

DUCTSEAL

6

6