daycare facility 1171 e calaveras blvd, …...project directory phong nguyen [email protected] the...

7
DN UP UP 853 SF 109 E 25 INFANTS/WADDLERS 829 SF 107 E 24 PRESCHOOL 2 573 SF 108 E 17 PRESCHOOL 3 753 SF 106 E 22 PRESCHOOL 1 397 SF 101 E 27 LOBBY 683 SF 111 E 20 PRESCHOOL 4 83 SF 110 E ELECT./STOR. 59 SF 104 E 0 STAFF RESTROOM 1 175 SF 103 E 12 KITCHEN 87 SF 102 E 1 OFFICE 3375 SF 119 E 68 PLAYGROUND 20 1 12 19 27 59 25 17 24 41 22 EXIT #1 LONGEST PATH (1ST FLR ONLY): 50' - 10.5" LONGEST PATH 1ST+2ND FLR: 124' - 11.25" 9' - 0 1/2" 9' - 5 1/2" 32' - 4 1/2" 34 34 34 34 EXIT #2 LONGEST PATH: 40' - 11.5" 23' - 1 1/2" 17' - 10" EXIT #3 LONGEST PATH: 51' - 2.5" 20 25 17' - 3" 33' - 11 1/2" EXIT #4 LONGEST PATH: 68' - 3.5" 6' - 3 1/2" 17' - 6" 17' - 6" 8' - 5" 24' - 10 1/2" EXIT #5 LONGEST PATH: 51' - 8" 9' - 0" 23' - 0 1/2" 19' - 7 1/2" 22 1883 SF 201 E 19 OPEN OFFICE 61 SF 202 E 0 STAFF RESTROOM 2 ROOF ROOF 19 18' - 3 3/4" 23' - 8" 20' - 0" 12' - 1" 3' - 0" GENERAL NOTES A. OCCUPANT LOAD FACTORS ARE ACCORDING TO CBC SECTION 1004, TABLE 1004.1.2. B. WHERE OCCUPANT LOAD SIGN IS REQUIRED, THE SIGN SHALL BE POSTED NEAR THE MAIN EXIT FROM THE ROOM. REFER TO SIGNAGE SCHEDULE FOR DETAILS. EXIT PLAN LEGEND OPEN OFFICE = ROOM NAME 130 = ROOM NUMBER B = OCCUPANCY GROUP * = ACCESSORY USE TO MAIN OCCUPANCY 2146 SF = FLOOR AREA IN SQUARE FEET 20 = OCCUPANT LOAD (CBC TABLE 1004.1.2) PATH OF EGRESS - 20 = OCCUPANT LOAD EXIT SIGN EXIT WIDTH CALCULATIONS EXIT WIDTH REQUIRED EXIT WIDTH PROVIDED x .15 = 8.85" 36" EXIT #1 20 B 2146 SF 130 OPEN OFFICE OCCUPANT LOAD SCHEDULE PER CBC 2013 TABLE 1004.1.2 SPACE USE OCCUPANT LOAD FACTOR SF / OCCUPANT ACCESSORY STORAGE AREAS MECHANICAL EQUIPMENT ROOM 300 GROSS 100 GROSS BUSINESS AREA 35 NET DAYCARE SITE ACCESSIBLE PATH OF TRAVEL FIRE EXTINGUISHER x .15 = 3" 36" EXIT #2 20 15 NET ASSEMBLY WITHOUT FIXED SEATS - UNCONCENTRATED TABLES & CHAIRS 50 GROSS EXERCISE ROOMS TOTAL OCCUPANTS TOTAL OCCUPANTS x .15 = 3.75" 36" EXIT #3 x .15 = 6.15" 36" EXIT #4 x .15 = 3.3" 36" EXIT #5 59 20 25 41 22 ENGINEER ARCHITECT Drawing Number Project Number Scale Date i n t e r i o r s p l a n n i n g a r c h i t e c t u r e 165 11th Street CA, 94103 [ T ] 415.314.7386 [ T ] 510.612.7758 www.studiobanaa.com indicates drawings have been released for construction. GENERAL NOTES 4. Copyright Bunton Mousavi Architecture Inc. 2019 2. This sheet is not to be used for construction unless the architect's 3. These plans and prints thereof, as instruments of service, 1. This sheet is part of a set and is not to be used alone. written consent of the architect is forbidden. stamp and signature appear on the drawings and the status box only. Reproduction and/or distribution without the prior are owned by the architect and are for use on this project REVISION HISTORY KEY Studio BANAA REN. 3-31-21 E R E C T E I I L T R O F C A C-36022 T O N T S L I A H DANE W. BUNTON C D A F A S N C I E As indicated A0.0 19009 07/19/2019 DAYCARE FACILITY PROJECT INFORMATION 1171 E CALAVERAS BLVD, MILPITAS, CA 95035 PLANNING SUBMITTAL ARCHITECT OWNER PROJECT DIRECTORY Phong Nguyen [email protected] THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT 1171 E. CALAVERAS BLVD IN MILPITAS. THE PROPOSAL WILL CONVERT A VACANT RESTAURANT AND MEDICAL OFFICE BUILDING INTO A DAYCARE FACILITY INCLUDING FOUR (4) PRESCHOOL ROOMS, (1) INFANT ROOM, A COMMON LOBBY, PRIVATE OFFICE, AND ADMINISTRATIVE OFFICES RELATED TO THE DAYCARE FACILITY ON THE SECOND FLOOR. THERE WILL BE NO DAYCARE OPERATION RELATED TO CHILDREN LOCATED ON THE SECOND FLOOR. EXTERIOR IMPROVEMENTS INCLUDE ADDITION OF A PLAYGROUND AREA, ADDITION OF EXTERIOR DOORS, AND MINOR RESTRIPING OF THE PARKING LOT TO INDICATE LOADING STALLS. CODES AND REGULATIONS USE THE FOLLOWING CODES AND REGULATIONS WITH LATEST AMENDMENTS AND SUPPLEMENTS: 1. CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, 2016 A. 2016 BUILDING STANDARDS ADMINISTRATIVE CODE PART 1, TITLE 24 C.C.R. B. 2016 CALIFORNIA BUILDING CODE (CBC) PART 2, TITLE 24, C.C.R. C. ASME A17.1 - 2013/CSA B44 - 13 SAFETY CODE FOR ELEVATORS AND ESCALATORS D. 2016 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24 C.C.R. E. TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS. 2. STRUCTURAL AND SEISMIC REQUIREMENTS: PART 2, TITLE 24 C.C.R. 3. ACCESSIBILITY GUIDELINES: CCR TITLE 24, PARTS 2, 3 AND 5 (DSA INTERPRETIVE MANUAL) 4. FIRE SAFETY (STATE FIRE MARSHAL): A. 2016 CALIFORNIA FIRE CODE (CFC), PART 9 TITLE 24 C.C.R. B. NFPA 72, NATIONAL FIRE ALARM, 2016 EDITION. C. CCR TITLE 19, CSFM REQUIREMENTS. D. NFPA - 13 INSTALLATION OF SPRINKLERS (2016 EDITION) E. NFPA - 14 STANDPIPE SYSTEMS (2016 EDITION) F. NFPA - 17 DRY CHEMICAL EXTINGUISHING SYSTEMS (2016 EDITION) G. NFPA - 17A WET CHEMICAL SYSTEMS (2016 EDITION) H. NFPA 20 STATIONARY PUMPS (2016 EDITION) I. NFPA - 24 PRIVATE FIRE MAINS (2016 EDITION) J. NFPA 72 NATIONAL FIRE ALARM CODE (CALIFORNIA AMENDED) (2016 EDITION) (NOTE SEE UL STANDARD 1971 FOR "VISUAL DEVICES") K. NFPA 253 CRITICAL RADIANT FLUX OF FLOOR COVERING SYSTEMS (2015 EDITION) L. NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS (2015 EDITION) REFERENCE CODE SECTION FOR NFPA STANDARDS - 2016 CBC (SFM) CHAPTER 35 5. ELECTRICAL REQUIREMENTS: 2016 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. 6. MECHANICAL REQUIREMENTS: 2016 CALIFORNIA MECHANICAL CODE (CMC) PART 4, TITLE 24 C.C.R. 7. PLUMBING REQUIREMENTS: 2016 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. 8. 2016 CALIFORNIA ENERGY CODE PART 6, TITLE 24 C.C.R. 9. 2016 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R. 10. CONSTRUCTION SAFETY (CAL - OSHA), CCR TITLE 8. 11. RULES AND REGULATIONS OF THE LOCAL TELEPHONE COMPANY 12. RULES AND REGULATIONS OF THE LOCAL UTILITY COMPANIES PROJECT DESCRIPTION Bunton Mousavi Architecture Inc. d.b.a. "Studio BANAA" 165 11th Street San Francisco, CA 94103 Dane Bunton (C36022) Principal Architect 510 - 612 - 7758 [email protected] LIST OF DRAWINGS ARCHITECTURAL BUILDING DATA APN #:_____________________________________________029 - 13 - 039 BUILDING USE (EXISTING):_______RESTAURANT & MEDICAL OFFICE BUILDING USE (PROPOSED): __________________________DAYCARE BUILDING OCCUPANCY (EXISTING):___________A - 2 (RESTAURANT) / B (MEDICAL OFFICE) BUILDING OCCUPANCY (PROPOSED): _________________________E TYPE OF CONSTRUCTION (EXISTING):________________________V - B TYPE OF CONSTRUCTION (PROPOSED):___________ ___________V - B FULLY SPRINKLERED (EXISTING)?____________________________NO FULLY SPRINKLERED (PROPOSED)?_________________________YES (FULLY SPRINKLERED) SQUARE FOOTAGE : ________________________________7,379 SQ FT # OF STORIES:______________________________________2 STORIES LOT SIZE: __________________________________________0.69 ACRES OVERALL ADDED FLOOR AREA:____________________________NONE N PROJECT SITE VICINITY MAP A0.0 PROJECT INFORMATION A1.0 SITE PLAN - EXISTING A1.1 SITE PLAN - PROPOSED A2.0 FLOOR PLANS - EXISTING/ DEMOLITION A2.1 FLOOR PLANS - PROPOSED A5.0 EXTERIOR ELEVATIONS - EXISTING/ DEMOLITION A5.1 EXTERIOR ELEVATIONS - PROPOSED DAYCARE FACILITY DEFERRED APPROVALS NONE EXISTING/PROPOSED EXTERIOR NO. REMARKS DATE 1 Plan Check #1 7/18/2019 1171 E CALAVERAS BLVD, MILPITAS, CA 95035 CHILD CARE CALCULATION 35/sf INTERIOR SPACE PER CHILD ROOM NAME SQ. FT. # OF CHILDREN AGE OF CHILD PRESCHOOL 1 753 sf 753/35 = 22 (21.5) 2 - 4 years PRESCHOOL 2 829 sf 829/35 = 24 (23.6) 2 - 4 years PRESCHOOL 3 573 sf 573/35 = 17 (16.37) 2 - 4 years PRESCHOOL 4 683 sf 683/35 = 20 (19.5) 2 - 4 years INFANTS/WADDLERS 853 sf 853/35 = 25 (24.37) 6weeks - 2yr TOTAL 108 CHILDREN 1 CODE ANALYSIS 1 1/16" = 1' - 0" 1 GROUND FLOOR / SITE - EXIT PLAN 1 1/16" = 1' - 0" 2 SECOND FLOOR EXIT PLAN

Upload: others

Post on 25-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DAYCARE FACILITY 1171 E CALAVERAS BLVD, …...PROJECT DIRECTORY Phong Nguyen phong59@gmail.com THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT

DN

UP

UP

853 SF

109E

25

INFANTS/WADDLERS

829 SF

107E

24

PRESCHOOL 2

573 SF

108E

17

PRESCHOOL 3

753 SF

106E

22

PRESCHOOL 1

397 SF

101E

27

LOBBY

683 SF

111E

20

PRESCHOOL 4

83 SF

110E

ELECT./STOR.

59 SF

104E

0

STAFFRESTROOM 1

175 SF

103E

12

KITCHEN

87 SF

102E

1

OFFICE

3375 SF

119E

68

PLAYGROUND

20

1

12

19

27

59

25

1724

41

22

EXIT #1LONGEST PATH (1ST FLR ONLY): 50'-10.5"LONGEST PATH 1ST+2ND FLR: 124'-11.25"

9' - 0

1/2

"

9' - 5 1/2"

32' -

4 1/

2"

34 34

34

34

EXIT #2LONGEST PATH: 40'-11.5"

23' -

1 1/

2"

17' - 10"

EXIT #3LONGEST PATH: 51'-2.5"

20

25

17' -

3"

33' - 11 1/2"

EXIT #4LONGEST PATH: 68'-3.5"

6' - 3 1/2"

17' -

6"

17' - 6"

8' - 5

"

24' - 10 1/2"

EXIT #5LONGEST PATH: 51'-8"

9' - 0"

23' -

0 1/

2"

19' - 7 1/2"

22

1883 SF

201E

19

OPEN OFFICE

61 SF

202E

0

STAFFRESTROOM 2

ROOF

ROOF

19

18' - 3 3/4"

23' - 8"

20' -

0"

12' - 1"

3' - 0

"

GENERAL NOTES

A. OCCUPANT LOAD FACTORS ARE ACCORDING TO CBC SECTION 1004, TABLE 1004.1.2.

B. WHERE OCCUPANT LOAD SIGN IS REQUIRED, THE SIGN SHALL BE POSTED NEAR THE MAIN EXIT FROM THE ROOM. REFER TO SIGNAGE SCHEDULE FOR DETAILS.

EXIT PLAN LEGEND

OPEN OFFICE = ROOM NAME

130 = ROOM NUMBER

B = OCCUPANCY GROUP* = ACCESSORY USE TO MAIN OCCUPANCY

2146 SF = FLOOR AREA IN SQUARE FEET

20 = OCCUPANT LOAD (CBC TABLE 1004.1.2)

PATH OF EGRESS - 20 = OCCUPANT LOAD

EXIT SIGN

EXIT WIDTH CALCULATIONS

EXIT WIDTH REQUIRED

EXIT WIDTH PROVIDED

x .15 = 8.85" 36"EXIT #1

20

B

2146 SF

130OPEN OFFICE

OCCUPANT LOAD SCHEDULEPER CBC 2013 TABLE 1004.1.2

SPACE USEOCCUPANT LOAD FACTOR

SF / OCCUPANT

ACCESSORY STORAGE AREASMECHANICAL EQUIPMENT ROOM 300 GROSS

100 GROSSBUSINESS AREA

35 NETDAYCARE

SITE ACCESSIBLE PATH OF TRAVEL

FIRE EXTINGUISHER

x .15 = 3" 36"EXIT #2

20

15 NETASSEMBLY WITHOUT FIXED SEATS -UNCONCENTRATED TABLES & CHAIRS

50 GROSSEXERCISE ROOMS

TOTAL OCCUPANTS

TOTAL OCCUPANTS

x .15 = 3.75" 36"EXIT #3

x .15 = 6.15" 36"EXIT #4

x .15 = 3.3" 36"EXIT #5

59

20

25

41

22

ENGINEERARCHITECT

Drawing Number

Project Number

Scale

Date

i n t e r i o r sp l a n n i n ga r c h i t e c t u r e

165 11th StreetCA, 94103

[ T ] 415.314.7386[ T ] 510.612.7758

www.studiobanaa.com

indicates drawings have been released for construction.

GENE

RAL N

OTES

4. Copyright Bunton Mousavi Architecture Inc. 2019

2. This sheet is not to be used for construction unless the architect's

3. These plans and prints thereof, as instruments of service,

1. This sheet is part of a set and is not to be used alone.

written consent of the architect is forbidden.

stamp and signature appear on the drawings and the status box

only. Reproduction and/or distribution without the prior are owned by the architect and are for use on this project

REVI

SION

HIS

TORY

KEY

Studio BANAA

REN. 3-31-21

E R

EC

TE

I

I

L T

R

OF CA

C-36022

T

ON

T

S

L I

A

H

DANE W. BUNTON

CD A

F

A

SN

CIE

As indicated A0.019009

07/19/2019

DAYCARE FACILITY

PROJECT INFORMATION

1171 E CALAVERAS BLVD,MILPITAS, CA 95035

PLANNING SUBMITTAL

ARCHITECT

OWNER

PROJECT DIRECTORY

Phong [email protected]

THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT 1171 E. CALAVERAS BLVD IN MILPITAS. THE PROPOSAL WILL CONVERT A VACANT RESTAURANT AND MEDICAL OFFICE BUILDING INTO A DAYCARE FACILITY INCLUDING FOUR (4) PRESCHOOL ROOMS, (1) INFANT ROOM, A COMMON LOBBY, PRIVATE OFFICE, AND ADMINISTRATIVE OFFICES RELATED TO THE DAYCARE FACILITY ON THE SECOND FLOOR.

THERE WILL BE NO DAYCARE OPERATION RELATED TO CHILDREN LOCATED ON THE SECOND FLOOR. EXTERIOR IMPROVEMENTS INCLUDE ADDITION OF A PLAYGROUND AREA, ADDITION OF EXTERIOR DOORS, AND MINOR RESTRIPING OF THE PARKING LOT TO INDICATE LOADING STALLS.

CODES AND REGULATIONSUSE THE FOLLOWING CODES AND REGULATIONS WITH LATEST AMENDMENTS AND SUPPLEMENTS:

1. CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, 2016A. 2016 BUILDING STANDARDS ADMINISTRATIVE CODE PART 1, TITLE

24 C.C.R.B. 2016 CALIFORNIA BUILDING CODE (CBC) PART 2, TITLE 24, C.C.R. C. ASME A17.1-2013/CSA B44-13 SAFETY CODE FOR ELEVATORS AND

ESCALATORSD. 2016 CALIFORNIA REFERENCED STANDARDS CODE, PART 12,

TITLE 24 C.C.R.E. TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL

REGULATIONS.

2. STRUCTURAL AND SEISMIC REQUIREMENTS: PART 2, TITLE 24 C.C.R.

3. ACCESSIBILITY GUIDELINES: CCR TITLE 24, PARTS 2, 3 AND 5 (DSA INTERPRETIVE MANUAL)

4. FIRE SAFETY (STATE FIRE MARSHAL):A. 2016 CALIFORNIA FIRE CODE (CFC), PART 9 TITLE 24 C.C.R.B. NFPA 72, NATIONAL FIRE ALARM, 2016 EDITION.C. CCR TITLE 19, CSFM REQUIREMENTS.D. NFPA-13 INSTALLATION OF SPRINKLERS (2016 EDITION)E. NFPA-14 STANDPIPE SYSTEMS (2016 EDITION)F. NFPA -17 DRY CHEMICAL EXTINGUISHING SYSTEMS (2016

EDITION)G. NFPA-17A WET CHEMICAL SYSTEMS (2016 EDITION)H. NFPA 20 STATIONARY PUMPS (2016 EDITION)I. NFPA-24 PRIVATE FIRE MAINS (2016 EDITION)J. NFPA 72 NATIONAL FIRE ALARM CODE (CALIFORNIA AMENDED)

(2016 EDITION) (NOTE SEE UL STANDARD 1971 FOR "VISUAL DEVICES")K. NFPA 253 CRITICAL RADIANT FLUX OF FLOOR COVERING

SYSTEMS (2015 EDITION)L. NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS (2015

EDITION) REFERENCE CODE SECTION FOR NFPA STANDARDS - 2016 CBC (SFM) CHAPTER 35

5. ELECTRICAL REQUIREMENTS: 2016 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. 6. MECHANICAL REQUIREMENTS: 2016 CALIFORNIA MECHANICAL CODE (CMC) PART 4, TITLE 24 C.C.R. 7. PLUMBING REQUIREMENTS: 2016 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. 8. 2016 CALIFORNIA ENERGY CODE PART 6, TITLE 24 C.C.R.

9. 2016 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R. 10. CONSTRUCTION SAFETY (CAL-OSHA), CCR TITLE 8.

11. RULES AND REGULATIONS OF THE LOCAL TELEPHONE COMPANY

12. RULES AND REGULATIONS OF THE LOCAL UTILITY COMPANIES

PROJECT DESCRIPTION

Bunton Mousavi Architecture Inc.d.b.a. "Studio BANAA"165 11th StreetSan Francisco, CA 94103

Dane Bunton (C36022)Principal [email protected]

LIST OF DRAWINGSARCHITECTURAL

BUILDING DATA

APN #:_____________________________________________029-13-039

BUILDING USE (EXISTING):_______RESTAURANT & MEDICAL OFFICE

BUILDING USE (PROPOSED): __________________________DAYCARE

BUILDING OCCUPANCY (EXISTING):___________A-2 (RESTAURANT) / B (MEDICAL OFFICE)

BUILDING OCCUPANCY (PROPOSED): _________________________E

TYPE OF CONSTRUCTION (EXISTING):________________________V-B

TYPE OF CONSTRUCTION (PROPOSED):___________ ___________V-B

FULLY SPRINKLERED (EXISTING)?____________________________NO

FULLY SPRINKLERED (PROPOSED)?_________________________YES(FULLY SPRINKLERED)

SQUARE FOOTAGE : ________________________________7,379 SQ FT

# OF STORIES:______________________________________2 STORIES

LOT SIZE: __________________________________________0.69 ACRES

OVERALL ADDED FLOOR AREA:____________________________NONE

N

PROJECT SITE

VICINITY MAP

A0.0 PROJECT INFORMATIONA1.0 SITE PLAN - EXISTINGA1.1 SITE PLAN - PROPOSEDA2.0 FLOOR PLANS - EXISTING/ DEMOLITIONA2.1 FLOOR PLANS - PROPOSEDA5.0 EXTERIOR ELEVATIONS - EXISTING/

DEMOLITIONA5.1 EXTERIOR ELEVATIONS - PROPOSED

DAYCARE FACILITY

DEFERRED APPROVALS

NONE

EXISTING/PROPOSED EXTERIOR

NO. REMARKS DATE1 Plan Check #1 7/18/2019

1171 E CALAVERAS BLVD, MILPITAS, CA 95035

CHILD CARE CALCULATION

35/sf INTERIOR SPACE PER CHILD

ROOM NAME SQ. FT. # OF CHILDREN AGE OF CHILD

PRESCHOOL 1 753 sf 753/35 = 22 (21.5) 2-4 yearsPRESCHOOL 2 829 sf 829/35 = 24 (23.6) 2-4 yearsPRESCHOOL 3 573 sf 573/35 = 17 (16.37) 2-4 yearsPRESCHOOL 4 683 sf 683/35 = 20 (19.5) 2-4 yearsINFANTS/WADDLERS 853 sf 853/35 = 25 (24.37) 6weeks - 2yr

TOTAL 108 CHILDREN

1

CODE ANALYSIS

1

1/16" = 1'-0"1GROUND FLOOR / SITE - EXIT PLAN

1

1/16" = 1'-0"2SECOND FLOOR EXIT PLAN

daneb
Dane Stamp
Page 2: DAYCARE FACILITY 1171 E CALAVERAS BLVD, …...PROJECT DIRECTORY Phong Nguyen phong59@gmail.com THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT

PT PTPT

SW SWSW

UP

DN

DN

SW

SWSW

SWSW

SWSW

SWSW

SW

PT

PT

PTPT

PTPT

PTPT

PTPT

SWSW SWSWSWSWSWSWSWSW

LEGENDSITE PROPERTY LINE

AREA OF MODIFICATION

INDICATES EXISTING SHRUB TO REMAIN

INDICATES EXISTING TREE TO REMAIN

INDICATES EXISTING PARKING SPACE TO REMAIN

INDICATES EXISTING ACCESSIBLE PARKING SPACE TO REMAIN

INDICATES EXISTING TREE TO REMAIN

INDICATES EXISTING SHRUB TO BE REMOVED

INDICATES EXISTING CURB/ WALL TO BE REMOVED

INDICATES EXISTING CURB/ WALL TO REMAIN

INDICATES EXISTING S.O.G. TO REMAIN

INDICATES EXISTING S.O.G. TO BE REMOVED

INDICATES NEW SLAB-ON-GRADE

INDICATES EXISTING LANDSCAPE AREA TO REMAIN

INDICATES EXISTING LANDSCAPE AREA TO BE REMOVED

INDICATES NEW TREE

(E) SANITARY SEWER

(E) P.T. & T.

GENERAL NOTES1. NONE

PARKING CALCULATIONTENANT SF/# ZONING REQ. TOTAL

REQ.TOTAL PROV.

CLASSROOMS 3,931 sfor 5

1 PER CLASSROOM OR 1 PER 500 SF, WHICHEVER IS GREATER

8 (SF CALC)

8

EMPLOYEES11 EMPLOYEES

1 PER 1.5 EMPLOYEES 8 8

OFFICE 1,883 sf 1 PER 240 sf 8 9

LOADING/UNLOADING

-

1 PER 6 CHILDREN UP TO 5 STALLS, THEREAFTER 1 PER 10 CHILDREN

13 13

TOTAL PARKING 37 37

INCLUDES (2) ACCESSIBLE

(E) STORAGE (E) SERVICE YARD

1171 E. CALAVERAS BLVD.2-STORY BUILDING

1

2

3

4

5

6

7

8

9

10

1112131415161720

38

37

36

35

34

33

32

31

30

1819

AYER STREET

TRASH/ RECYCLE LOCATION

29(COMPACT)

28(COMPACT)

27(COMPACT)

26(COMPACT)

25(COMPACT)

24(COMPACT)

23(COMPACT)

22(COMPACT)

21(COMPACT)

REMOVE (E) EUCALYPTUS TREE. 40" CIRCUMFERENCE

(E) SANITARY SEWER EASEMENT20' - 0"

(E) P.T. & T. EASEMENT25' - 0"

(E) 10'-0" P.M.U.E.

(E) 10'-0" P.M.U.E.(E) 10'-0" P.M.U.E.

(E) ELECT.

(E) DRIVEWAY(E) DRIVEWAY

(E) RAMP

(E) SPEED BUMP

(E) DRIVEWAY

ENGINEERARCHITECT

Drawing Number

Project Number

Scale

Date

i n t e r i o r sp l a n n i n ga r c h i t e c t u r e

165 11th StreetCA, 94103

[ T ] 415.314.7386[ T ] 510.612.7758

www.studiobanaa.com

indicates drawings have been released for construction.

GENE

RAL N

OTES

4. Copyright Bunton Mousavi Architecture Inc. 2019

2. This sheet is not to be used for construction unless the architect's

3. These plans and prints thereof, as instruments of service,

1. This sheet is part of a set and is not to be used alone.

written consent of the architect is forbidden.

stamp and signature appear on the drawings and the status box

only. Reproduction and/or distribution without the prior are owned by the architect and are for use on this project

REVI

SION

HIS

TORY

KEY

Studio BANAA

REN. 3-31-21

E R

EC

TE

I

I

L T

R

OF CA

C-36022

T

ON

T

S

L I

A

H

DANE W. BUNTON

CD A

F

A

SN

CIE

As indicated A1.019009

07/19/2019

DAYCARE FACILITY

SITE PLAN - EXISTING

1171 E CALAVERAS BLVD,MILPITAS, CA 95035

PLANNING SUBMITTAL

N

3/32" = 1'-0"1SITE PLAN - EXISTING/ DEMOLITION

NO. REMARKS DATE1 Plan Check #1 7/18/2019

daneb
Dane Stamp
Page 3: DAYCARE FACILITY 1171 E CALAVERAS BLVD, …...PROJECT DIRECTORY Phong Nguyen phong59@gmail.com THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT

PT PTPT

SW SWSW

DN

UP

SW

SWSW

SWSW

SWSW

SWSW

SW

PT

PT

PTPT

PTPT

PTPT

PTPT

SWSW SWSWSWSWSWSWSWSW

LEGENDSITE PROPERTY LINE

AREA OF MODIFICATION

INDICATES EXISTING SHRUB TO REMAIN

INDICATES EXISTING TREE TO REMAIN

INDICATES EXISTING PARKING SPACE TO REMAIN

INDICATES EXISTING ACCESSIBLE PARKING SPACE TO REMAIN

INDICATES EXISTING TREE TO REMAIN

INDICATES EXISTING SHRUB TO BE REMOVED

INDICATES EXISTING CURB/ WALL TO BE REMOVED

INDICATES EXISTING CURB/ WALL TO REMAIN

INDICATES EXISTING S.O.G. TO REMAIN

INDICATES EXISTING S.O.G. TO BE REMOVED

INDICATES NEW SLAB-ON-GRADE

INDICATES EXISTING LANDSCAPE AREA TO REMAIN

INDICATES EXISTING LANDSCAPE AREA TO BE REMOVED

INDICATES NEW TREE

(E) SANITARY SEWER

(E) P.T. & T.

GENERAL NOTES1. NONE

PARKING CALCULATIONTENANT SF/# ZONING REQ. TOTAL

REQ.TOTAL PROV.

CLASSROOMS 3,931 sfor 5

1 PER CLASSROOM OR 1 PER 500 SF, WHICHEVER IS GREATER

8 (SF CALC)

8

EMPLOYEES11 EMPLOYEES

1 PER 1.5 EMPLOYEES 8 8

OFFICE 1,883 sf 1 PER 240 sf 8 9

LOADING/UNLOADING

-

1 PER 6 CHILDREN UP TO 5 STALLS, THEREAFTER 1 PER 10 CHILDREN

13 13

TOTAL PARKING 37 37

INCLUDES (2) ACCESSIBLE

1171 E. CALAVERAS BLVD.2-STORY BUILDING

1

2

3

4

5

TRASH/ RECYCLE LOCATION

37

36

35

34

33

32

31

30

29

LOADING17

LOADING16

LOADING15

LOADING14

LOADING13

LOADING12

LOADING11

LOADING10

LOADING9

LOADING8

LOADING6

AYER STREET

(N) 6' HIGH WOOD FENCE

GRADE (E) TOPOGRAPHY

PRIMARY ENTRANCE

(N) WOOD GATE TO MATCH FENCE

INFANT/WADDLER PRIMARY ENTRANCE

28(COMPACT)

27(COMPACT)

26(COMPACT)

25(COMPACT)

24(COMPACT)

23(COMPACT)

22(COMPACT)

21(COMPACT)

20(COMPACT)

ACCESSIBLE19

ACCESSIBLELOADING

18

APPLE TREE,OR APPROVED EQUAL WITH NON-INVASIVE ROOT SYSTEM

LOADING7

(N) CONC. WALKWAY(E) SANITARY SEWER EASEMENT20' - 0"

(E) P.T. & T. EASEMENT25' - 0"

(E) 10'-0" P.M.U.E.

(E) 10'-0" P.M.U.E.(E) 10'-0" P.M.U.E.

(E) ELECT.

(E) DRIVEWAY

(E) RAMP

(E) SPEED BUMP

5' - 8

"

(N) WOOD GATE TO MATCH FENCE3375 SF

PLAYGROUND119

20' -

0" C

LR. A

CCES

S PA

TH

20' - 0" CLR. ACCESS PATH

20' -

0" C

LR. A

CCES

S PA

TH

20' - 0" CLR. ACCESS PATH

(E) DRIVEWAY

ENGINEERARCHITECT

Drawing Number

Project Number

Scale

Date

i n t e r i o r sp l a n n i n ga r c h i t e c t u r e

165 11th StreetCA, 94103

[ T ] 415.314.7386[ T ] 510.612.7758

www.studiobanaa.com

indicates drawings have been released for construction.

GENE

RAL N

OTES

4. Copyright Bunton Mousavi Architecture Inc. 2019

2. This sheet is not to be used for construction unless the architect's

3. These plans and prints thereof, as instruments of service,

1. This sheet is part of a set and is not to be used alone.

written consent of the architect is forbidden.

stamp and signature appear on the drawings and the status box

only. Reproduction and/or distribution without the prior are owned by the architect and are for use on this project

REVI

SION

HIS

TORY

KEY

Studio BANAA

REN. 3-31-21

E R

EC

TE

I

I

L T

R

OF CA

C-36022

T

ON

T

S

L I

A

H

DANE W. BUNTON

CD A

F

A

SN

CIE

As indicated A1.119009

07/19/2019

DAYCARE FACILITY

SITE PLAN - PROPOSED

1171 E CALAVERAS BLVD,MILPITAS, CA 95035

PLANNING SUBMITTAL

N

3/32" = 1'-0"1SITE PLAN - PROPOSED

NO. REMARKS DATE1 Plan Check #1 7/18/2019

1

1

1

1

1

1

daneb
Dane Stamp
Page 4: DAYCARE FACILITY 1171 E CALAVERAS BLVD, …...PROJECT DIRECTORY Phong Nguyen phong59@gmail.com THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT

UP

UP

DN

DN

DN

1

5

D

2

4

ABC

3

3.5

(E) STORAGE (E) SERVICE YARD

ELECTRICAL

(E) STORAGE #2

(E) COOKING AREA

(E) WALK-IN REFRIGERATOR/ FREEZER (E) DINING ROOM #2

(E) LOBBY

(E) DINING ROOM #3(E) COCKTAIL LOUNGE

(E) DINING ROOM #1

(E) SERVICE STATION #2

(E) SERVICE STATION #1

(E) ENTRY

(E) BAR

(E) DISHWASHING

GENERAL NOTES

1. REMOVE ALL EXISTING INTERIOR WALL FINISHES, U.O.N.

2. PRESERVE (E) FLOOR WHERE APPLICABLE, SEE FINISH PLAN A2.3 & A2.4

LEGEND

EXISTING WALL TO REMAIN

DEMOLISHED WALL/ELEMENT

1

5

D

2

4

ABC

3

3.5

(E) ROOF DECK

(E) ROOFTOP MECH AREA

OPEN TO BELOW

(E) ROOF

DINING AREA #4B

STAFF ROOM

WOMEN'S DRESSING

MEN'S DRESSING

(E) DINING AREA #4C

(E) STORAGE ROOM #4

(E) DINING AREA #4A

(E) SERVICE STATION #4

1/8" = 1'-0"1GROUND FLOOR PLAN - EXISTING/ DEMOLITION

ENGINEERARCHITECT

Drawing Number

Project Number

Scale

Date

i n t e r i o r sp l a n n i n ga r c h i t e c t u r e

165 11th StreetCA, 94103

[ T ] 415.314.7386[ T ] 510.612.7758

www.studiobanaa.com

indicates drawings have been released for construction.

GENE

RAL N

OTES

4. Copyright Bunton Mousavi Architecture Inc. 2019

2. This sheet is not to be used for construction unless the architect's

3. These plans and prints thereof, as instruments of service,

1. This sheet is part of a set and is not to be used alone.

written consent of the architect is forbidden.

stamp and signature appear on the drawings and the status box

only. Reproduction and/or distribution without the prior are owned by the architect and are for use on this project

REVI

SION

HIS

TORY

KEY

Studio BANAA

REN. 3-31-21

E R

EC

TE

I

I

L T

R

OF CA

C-36022

T

ON

T

S

L I

A

H

DANE W. BUNTON

CD A

F

A

SN

CIE

As indicated A2.019009

07/19/2019

DAYCARE FACILITY

FLOOR PLANS -EXISTING/ DEMOLITION

1171 E CALAVERAS BLVD,MILPITAS, CA 95035

PLANNING SUBMITTAL

1/8" = 1'-0"2FIRST FLOOR PLAN - EXISTING/ DEMOLITION

NO. REMARKS DATE

0 8' 16'

N

0 8' 16'

N

daneb
Dane Stamp
Page 5: DAYCARE FACILITY 1171 E CALAVERAS BLVD, …...PROJECT DIRECTORY Phong Nguyen phong59@gmail.com THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT

UP

UP

DN

DN

DN

1

5

D

2

A5.1

4

4

ABC

3

3.5

6' - 4 1/2"4' - 0"

853 SF

INFANTS/WADDLERS109

829 SF

PRESCHOOL 2107

573 SF

PRESCHOOL 3108

753 SF

PRESCHOOL 1106

397 SF

LOBBY101

683 SF

PRESCHOOL 4111

83 SF

ELECT./STOR.110

PART

IAL H

T. W

ALL

PART

IAL H

T. W

ALL

PART

IAL H

T. W

ALL

REF. REF. REF.CHANGING

59 SF

STAFF RESTROOM 1104

41 SF

CLOSET105

1' - 0"

4' - 0"

REF. REF.

DWDW

175 SF

KITCHEN103

87 SF

OFFICE102

5' - 0

"

(N) EXIT DOOR

(N) EXIT DOOR(N) EXIT DOOR

4' - 0"

94 SF

RESTROOM PS4115

50 SF

RESTROOM PS3116

50 SF

RESTROOM PS2117

48 SF

RESTROOM PS1118

1

5

D

2

4

ABC

3

3.5

OPEN TO BELOW

1883 SF

OPEN OFFICE201

61 SF

STAFF RESTROOM 2202

PATCH FLOOR, MATCH EXISTING

54 SF

STORAGE114

ROOF

ROOF

ENGINEERARCHITECT

Drawing Number

Project Number

Scale

Date

i n t e r i o r sp l a n n i n ga r c h i t e c t u r e

165 11th StreetCA, 94103

[ T ] 415.314.7386[ T ] 510.612.7758

www.studiobanaa.com

indicates drawings have been released for construction.

GENE

RAL N

OTES

4. Copyright Bunton Mousavi Architecture Inc. 2019

2. This sheet is not to be used for construction unless the architect's

3. These plans and prints thereof, as instruments of service,

1. This sheet is part of a set and is not to be used alone.

written consent of the architect is forbidden.

stamp and signature appear on the drawings and the status box

only. Reproduction and/or distribution without the prior are owned by the architect and are for use on this project

REVI

SION

HIS

TORY

KEY

Studio BANAA

REN. 3-31-21

E R

EC

TE

I

I

L T

R

OF CA

C-36022

T

ON

T

S

L I

A

H

DANE W. BUNTON

CD A

F

A

SN

CIE

1/8" = 1'-0" A2.119009

07/19/2019

DAYCARE FACILITY

FLOOR PLANS -PROPOSED

1171 E CALAVERAS BLVD,MILPITAS, CA 95035

PLANNING SUBMITTAL

1/8" = 1'-0"1GROUND FLOOR PLAN - PROPOSED0 8' 16'

N

NO. REMARKS DATE

1/8" = 1'-0"2SECOND FLOOR PLAN - PROPOSED 0 8' 16'

N

daneb
Dane Stamp
Page 6: DAYCARE FACILITY 1171 E CALAVERAS BLVD, …...PROJECT DIRECTORY Phong Nguyen phong59@gmail.com THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT

T.O.GROUNDFLOOR

0' - 0"

T.O. FIRST FLOOR11' - 6"

D

B.O.ROOF22' - 6"

A B C

ROOF RIDGE36' - 2 1/2"

T.O.GROUNDFLOOR

0' - 0"

T.O. FIRST FLOOR11' - 6"

15 2

B.O.ROOF22' - 6"

4 3 3.5

ROOF RIDGE36' - 2 1/2"

T.O.GROUNDFLOOR

0' - 0"

T.O. FIRST FLOOR11' - 6"

D

B.O.ROOF22' - 6"

ABC

ROOF RIDGE36' - 2 1/2"

T.O.GROUNDFLOOR

0' - 0"

T.O. FIRST FLOOR11' - 6"

1 52

B.O.ROOF22' - 6"

433.5

ROOF RIDGE36' - 2 1/2"

EXISTING STUCCO

EXISTING WOOD SIDING

LEGEND

EXISTING ROOF SHINGLES

EXISTING ELEMENTS TO BE DEMOLISHED

ENGINEERARCHITECT

Drawing Number

Project Number

Scale

Date

i n t e r i o r sp l a n n i n ga r c h i t e c t u r e

165 11th StreetCA, 94103

[ T ] 415.314.7386[ T ] 510.612.7758

www.studiobanaa.com

indicates drawings have been released for construction.

GENE

RAL N

OTES

4. Copyright Bunton Mousavi Architecture Inc. 2019

2. This sheet is not to be used for construction unless the architect's

3. These plans and prints thereof, as instruments of service,

1. This sheet is part of a set and is not to be used alone.

written consent of the architect is forbidden.

stamp and signature appear on the drawings and the status box

only. Reproduction and/or distribution without the prior are owned by the architect and are for use on this project

REVI

SION

HIS

TORY

KEY

Studio BANAA

REN. 3-31-21

E R

EC

TE

I

I

L T

R

OF CA

C-36022

T

ON

T

S

L I

A

H

DANE W. BUNTON

CD A

F

A

SN

CIE

As indicated A5.019009

07/19/2019

DAYCARE FACILITY

EXTERIOR ELEVATIONS -EXISTING/ DEMOLITION

1171 E CALAVERAS BLVD,MILPITAS, CA 95035

PLANNING SUBMITTAL

1/8" = 1'-0"4EXISTING EAST ELEVATION

1/8" = 1'-0"1EXISTING SOUTH ELEVATION

1/8" = 1'-0"2EXISTING WEST ELEVATION

1/8" = 1'-0"3EXISTING NORTH ELEVATION

NO. REMARKS DATE

daneb
Dane Stamp
Page 7: DAYCARE FACILITY 1171 E CALAVERAS BLVD, …...PROJECT DIRECTORY Phong Nguyen phong59@gmail.com THE PROJECT CONSISTS OF AN INTERIOR REMODEL TO AN EXISTING COMMERCIAL SPACE LOCATED AT

T.O.GROUNDFLOOR

0' - 0"

T.O. FIRST FLOOR11' - 6"

5 2

B.O.ROOF22' - 6"

4 3 3.5

ROOF RIDGE36' - 2 1/2"

(N)

T.O.GROUNDFLOOR

0' - 0"

T.O. FIRST FLOOR11' - 6"

D

B.O.ROOF22' - 6"

ABC

ROOF RIDGE36' - 2 1/2"

GENERAL NOTES

-ALL ELEMENTS ARE EXISTING,UNLESS NOTED OTHERWISE (E) RETAINING WALL TO REMAIN

FINISH LEGEND

EXISTING WALL TO REMAIN

HARDIPANEL VERTICAL SIDING, WHITE

EXISTING ROOF TO REMAIN

T.O.GROUNDFLOOR

0' - 0"

T.O. FIRST FLOOR11' - 6"

D

B.O.ROOF22' - 6"

A B C

ROOF RIDGE36' - 2 1/2"

(N) W

OOD

FENC

E, P

TD6'

- 0"

(N) WOOD (PAINTED) & GLASS EXTERIOR DOOR

(N) WOOD (PAINTED) & GLASS EXTERIOR DOOR

T.O.GROUNDFLOOR

0' - 0"

T.O. FIRST FLOOR11' - 6"

1 52

B.O.ROOF22' - 6"

433.5

ROOF RIDGE36' - 2 1/2"

(N) WOOD (PAINTED) & GLASS EXTERIOR DOOR

(N) W

OOD

FENC

E, P

TD.

6' - 0

" (N)

ENGINEERARCHITECT

Drawing Number

Project Number

Scale

Date

i n t e r i o r sp l a n n i n ga r c h i t e c t u r e

165 11th StreetCA, 94103

[ T ] 415.314.7386[ T ] 510.612.7758

www.studiobanaa.com

indicates drawings have been released for construction.

GENE

RAL N

OTES

4. Copyright Bunton Mousavi Architecture Inc. 2019

2. This sheet is not to be used for construction unless the architect's

3. These plans and prints thereof, as instruments of service,

1. This sheet is part of a set and is not to be used alone.

written consent of the architect is forbidden.

stamp and signature appear on the drawings and the status box

only. Reproduction and/or distribution without the prior are owned by the architect and are for use on this project

REVI

SION

HIS

TORY

KEY

Studio BANAA

REN. 3-31-21

E R

EC

TE

I

I

L T

R

OF CA

C-36022

T

ON

T

S

L I

A

H

DANE W. BUNTON

CD A

F

A

SN

CIE

As indicated A5.119009

07/19/2019

DAYCARE FACILITY

EXTERIOR ELEVATIONS -PROPOSED

1171 E CALAVERAS BLVD,MILPITAS, CA 95035

PLANNING SUBMITTAL

1/8" = 1'-0"1PROPOSED SOUTH ELEVATION

1/8" = 1'-0"4PROPOSED WEST ELEVATION

NO. REMARKS DATE

1/8" = 1'-0"2PROPOSED EAST ELEVATION

daneb
Dane Stamp