dbb brochure

8
www.DowelBarsBaskets.com 816.994.9090 Paving T echnologies DBB Dowel Bars and Baskets, LLC ®

Upload: jessie-mcnellis

Post on 28-Mar-2016

228 views

Category:

Documents


2 download

DESCRIPTION

DBB Brochure

TRANSCRIPT

Page 1: DBB Brochure

www.DowelBarsBaskets.com816.994.9090

Paving Technologies

DBBDowel Bars and Baskets, LLC

®

Page 2: DBB Brochure

BesT in ProducT, service and suPPorT

DBB provides the best product, service and support for all of your dowel,

bar, basket needs. A dowel basket is a simple truss structure used to hold

dowel bars at the appropriate height before PCC placement. Typically,

dowel baskets span an entire lane width and are fabricated from thick

gauge wire. They are left in place after the PCC is placed but do not con-

tribute to the pavement structure.

When using dowel baskets, the dowels must be properly aligned and the

dowel basket firmly anchored to the base course. The FHWA recommends

that the dowel baskets be secured with steel stakes with a minimum di-

ameter of 8 mm (0.3 inches) embedded at least 100 mm (4 inches) in

stabilized bases, 150 mm (6 inches) in treated permeable bases and 250

mm (10 inches) for untreated bases or subgrade. Further, a minimum of 8

stakes per basket is recommended.

DBBDowel Bars and Baskets, LLC

®

Page 3: DBB Brochure

Retrofitting dowel bars is a method to reestablish load transfer across

joints or cracks. It requires cutting slots across each joint to house new

dowel bars.

The underlying purpose of retrofitting dowel bars is to repair faulted joints

or cracks and prevent recurrence of the faults. However, if the faulted

joints or cracks are already badly spalled, retrofitting dowels is not

recommended, and full- or partial-depth patching is necessary.

Load transfer refers to the ability of a joint to transfer a portion of a load

applied on one slab to an adjacent slab. The higher the load transfer, the

more evenly a load near a joint is distributed to the subbase and subgrade.

This usually translates into better pavement

performance. Poor load transfer generally leads to

faulting, pumping, corner breaks, or spalling.

load Transfer ProducTs

• Welded Dowel Assemblies

• Wire Baskets

• Basket Stakes

• Dowel Bars

• Tie Bar Assemblies

dowel Bar reTrofiT Technology

DBBDowel Bars and Baskets, LLC

®

Page 4: DBB Brochure

EXPANSION STYLE BASKET CONTRACTION STYLE BASKET

DIA X LENGTH AS SPECIFIED

SECTION : A-A

PROJECT INFORMATION

Name Project #

Nickname Bid Date

City/County Owner/Agency

State/Zip Delivery Date

DATE

DBBDowel Bars and Baskets, LLC

®

Page 5: DBB Brochure

Dowel Diameter

Length

Inch. Other Bond Breaker

Feet Inch. Per AssemblyAssemblyLength Feet Inch.

Tie Wire

Plain (Y or N)

Stake Wire Thickness

Lane Width

Paving Depth

WELDED DOWEL BASKET ASSEMBLY

Tectyl (Y or N)

DBB Product #: Quantity:

Lineal Feet This Item

Specification Thickness (mils)

Leg Type

A J or U

Specification

DOWEL BAR COATING

.262" .306" or .362"

Paint Color

Coverage (3/5 or Full)

Touch Welds (Y or N)

Thickness (mils) Touch Ends (Y or N)

Specification

Center to Center-Inch.

Specification

Thickness (mils) Thickness (mils)

Thickness (mils)

Specification

Contraction or Expansion

Expansion Joint Thickness

WIRE TYPE AND WIRE DIAMETERS

Basket Stake Qty.

Plain (Y or N)

Runner Wire Leg Wire

Epoxy Color

Tie wire will be .177 unless specified above.

Galvanized

.262" .306" or .362"

Epoxy Color

BASKET COATING

Paint Color

S:\Marketing\Creative\DBB\Sheets\page 2

DBBDowel Bars and Baskets, LLC

®

Page 6: DBB Brochure

DBB Product #:

Assembly Length Other Bond Breaker

Feet Inch. Basket Stake Qty.

A J or U

Plain (Y or N)

Tie wire will be .177 unless specified above.

Quantity:LONGITUDINAL LANE TIE OF DEFORMED REBAR WELDED TIE BAR BASKET ASSEMBLY

WIRE TYPE AND WIRE DIAMETERSLeg Wire

Length Center to Center-Inches

Leg Type

Lineal Feet This Item

Paving Depth

Tectyl (Y or N)

Stake Wire Thickness

Tie Bar Diameter

Thickness (mils) Touch Ends (Y or N)

TIE BAR COATINGPlain (Y or N) Epoxy Color GalvanizedPaint Color

Coverage (3/5 or Full)

Touch Welds (Y or N)

Epoxy Color Paint Color

Specification Specification Thickness (mils)

BASKET COATING

Thickness (mils) Specification

Thickness (mils) Specification

Tie Wire .262" .306" or .362"

Specification Thickness (mils)

Per Assembly

Runner Wire .262" .306" or .362"

S:\Marketing\Creative\DBB\Sheets\page 3

DBBDowel Bars and Baskets, LLC

®

Page 7: DBB Brochure

Quantity:

Steel: A36 or

A615-Grade 60

Other Steel:

DBB Product #:

Steel: A36 or A615-Grade 60Other Steel:

DEFORMED REBAR LANE TIE BAR COATINGPlain (Y or N)Paint Color Specification

Epoxy Color Galvanized Specification

Diameter (in) Tectyl (Y or N)Length (in) Other Bond Breaker

Specification Thickness (mils)

DBB Product #:

Paint ColorEpoxy Color

DOWELS ONLY

Other Bond Breaker

Tectyl (Y or N)

Length (in)

Diameter (in)

Bundle Quantity

Specification Thickness (mils)

DOWEL BAR COATING

Specification Thickness (mils)

Plain (Y or N) Galvanized

Bundle Quantity

Touch Ends

DEFORMED REBAR LANE TIE BARS ONLYQuantity:

Coverage (3/5 or Full)

Coverage (3/5 or Full)

Thickness (mils) Specification Thickness (mils) Thickness (mils) Touch Ends

S:\Marketing\Creative\DBB\Sheets\page 4

DBBDowel Bars and Baskets, LLC

®

Page 8: DBB Brochure

www.DowelBarsBaskets.com816.994.9090

Sales & Customer Service 1619 WalnutKansas City, MO 64108 P. (816) 994-9090 F. (816) 994-9091

Manufacturing420 Welch Drive Farmersville, TX 75442

DBBDowel Bars and Baskets, LLC

®