DECK HANDOUT - Updated 2019 BUILDING PERMITS: This handout intends to provide information on the minimum requirements applicable to the construction of a deck, whether attached to or detached from a residential dwelling. The Zoning Ordinance requires the issuance of a building permit prior to the construction of an attached deck or detached deck that is 30 inches or more above grade at any point within 5 feet of the perimeter of the deck. Decks and platforms less than 30 inches above adjacent grade and not attached to a structure with frost footings do not require a building permit. Please contact the Building Department at 952.447.9850 or Planning Department at 952.447.9810 for information on your specific project. SUBMITTALS FOR PERMIT: May be submitted online @ bsaonline.com/MunicipalDirectory the city website has a link. Signed completed building permit application - unless completing the application online. Attach a copy of the deck plan, drawn to scale and including: All dimensions drawn to scale Size, direction and spacing of joists Size and depth of footings Size and spacing of posts Size of beams and headers Size, direction and type of decking Stair location (if applicable) Attach a copy of a Certificate of survey with the deck drawn on it to scale. An existing certificate of survey may be used if all existing buildings, property lines, setback hubs, and easements are shown. The existing survey must be signed by a registered land surveyor. A current and updated survey may be required if additional information is needed to determine ordinance compliance such as yard setbacks, bluff setback, OHW setback, etc. The owner may elect to replace the existing deck with an exact replacement. By utilizing the replacement deck option, current setbacks are not required to be met. The replacement deck must be drawn on the existing survey to scale and must meet IBC/IRC requirements. The location and size of existing deck must be verified by City staff. Residential Decks City of Prior Lake Requirements

Upload: others

Post on 24-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

BUILDING PERMITS: This handout intends to provide information on the minimum requirements applicable to the construction of a deck, whether attached to or detached from a residential dwelling. The Zoning Ordinance requires the issuance of a building permit prior to the construction of an attached deck or detached deck that is 30 inches or more above grade at any point within 5 feet of the perimeter of the deck. Decks and platforms less than 30 inches above adjacent grade and not attached to a structure with frost footings do not require a building permit. Please contact the Building Department at 952.447.9850 or Planning Department at 952.447.9810 for information on your specific project. SUBMITTALS FOR PERMIT: May be submitted online @ bsaonline.com/MunicipalDirectory the city website has a link.

Signed completed building permit application - unless completing the application online. Attach a copy of the deck plan, drawn to scale and including:

All dimensions drawn to scale Size, direction and spacing of joists Size and depth of footings Size and spacing of posts Size of beams and headers Size, direction and type of decking Stair location (if applicable)

Attach a copy of a Certificate of survey with the deck drawn on it to scale. An existing

certificate of survey may be used if all existing buildings, property lines, setback hubs, and easements are shown. The existing survey must be signed by a registered land surveyor. A current and updated survey may be required if additional information is needed to determine ordinance compliance such as yard setbacks, bluff setback, OHW setback, etc.

The owner may elect to replace the existing deck with an exact replacement. By utilizing the replacement deck option, current setbacks are not required to be met. The replacement deck must be drawn on the existing survey to scale and must meet IBC/IRC requirements. The location and size of existing deck must be verified by City staff.

Residential Decks City of Prior Lake Requirements

Page 2: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

ZONING CODE REQUIREMENTS

MINIMUM SETBACKS: The Zoning Ordinance requires that decks maintain the following minimum setbacks in the R-1, R-2, and R-3 use districts:

Front: 25 feet Side: 10’ feet1 Rear: 25 feet

Shoreland: 75 feet2 Wetland: 30 feet Bluff: Minimum 25 feet3

Replacement decks that do not meet the minimum required setbacks may be replaced provided the deck: (1) existed on May 1, 1999, (2) is (a) the same size and (b) location, (c) constructed of wood, and (d) not covered, and (3) not located within an easement, the public right-of-way or over a property line. In lieu of a survey a site plan may be accepted. A Site Plan is a to-scale plan showing setbacks, existing structures, dimensions, distance from lot lines and the proposed replacement deck. ADDITIONAL ZONING INFORMATION: Decks with ¼ inch floorboard spacing are not considered impervious surface under the shoreland ordinance.

______________________________________________

1Non-conforming lots of record in the R-1 and R-2 use districts may have a reduced setback, but no less than 5 feet. See Section 1101.502 (8). 2Shoreland ordinance permits the use of the average setback of those properties within 150 feet, but setback can be no less than 50 feet. See Section 1104.308 (2). 3Bluff setback is the upper end of a segment at least 25 feet in length having an average slope less than 18 percent.

BUILDING CODE REQUIREMENTS

The International Building Code provides the following standards for the construction of a

deck requiring a permit. FROST FOOTINGS: Required for any deck attached to a dwelling, porch or garage that has frost footings. The minimum depth to the base of the footing is 42”. LIVE LOAD: All decks shall be designed to support a live load of forty (40) pounds per square foot.

Page 3: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

GUARDS: Required on all decks more than thirty (30) inches above grade or higher measured at 5’- 0” from deck perimeter. Guards must be thirty-six (36) inches minimum in height. Open guards must have intermediate rails or an ornamental pattern that a four (4) inch sphere cannot pass through. Guards are required on all stairs over thirty (30) inches above grade or higher. Guard height minimum is thirty-four (34) inches measured vertically from the stair tread nosing. The triangular openings formed by the riser, tread and bottom rail cannot let a 6” sphere pass through. Spacing for spindles of guards on the sides of stair treads shall not allow a four and three eighths (4 3/8”) inch sphere to pass through. CANTILEVERS “OVERHANGING JOISTS AND BEAMS”: 2’ x 10’ joists should not overhang beams by more than two (2) feet, nor should beams overhang posts by more than one (1) foot unless a special design is approved. 2’ x 8’ joists should not overhang beams by more than 1-1/2’ (18”), 2’ x 6’ joists should not overhang beams by more than 1’ (12”). FLASHING: All connections between deck and dwelling shall be weatherproof with an approved corrosion-resistant flashing and shall be applied shingle fashion in such a manner as to prevent entry of water into the wall cavity or penetration of water into the building structural framing components. Flashing is required for all ledger boards. FRAMING DETAILS: Header beams and joists over six (6) feet long that frame into ledgers or beams shall be supported by approved framing anchors such as joist hangers or beam hangers. NAILS & SCREWS: Use only stainless steel, high strength aluminum or hot-dipped galvanized fasteners. WOOD REQUIRED: All exposed wood used in the construction of decks is required to be of approved wood of natural resistance to decay (redwood, cedar, etc.) or approved treated wood. This includes posts, beams, joists, decking and railings. STAIRS: Minimum width is thirty-six (36) inches. Maximum rise is seven and three quarters (7 3/4) inches, minimum rise is four (4) inches. Minimum run is ten (10) inches. Largest tread width or riser height shall not exceed the smallest by more than three eighths (3/8) inch. Open risers are permitted, provided openings between treads do not permit the passage of a four (4) inch sphere. HANDRAILS: Stairways having four (4) or more risers shall have at least one (1) handrail. Handrails must be continuous for the full length of the stairs. The top shall be placed not less than thirty-four (34) inches or more than thirty-eight (38”) inches above the nosing of the treads. Handrail ends shall be returned or terminated at posts or walls. The hand grips shall not be less than one and one quarter (1 1/4) inches or more than two (2“) inches in cross-sectional dimension or the shape shall provide an equivalent graspability. The handgrip shall have a smooth surface with no sharp corners.

Page 4: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

SPECIAL DESIGN NOTE: Some deck designs may not be appropriate should the placement of a screen porch or three (3) season porch on the deck platform be a future consideration. Also special design provisions may be needed for decks being supported by cantilevered floor joist systems. LEDGER BOARD: Secure ledger board with two (2) 3/8 inch stainless steel, triple dipped zinc lag screws or equivalent at sixteen (16”) inches on center to support live loads of 40# per square foot and dead load of 10# per square foot and fastened to structural members (house rim or studs) with minimum of one and one half (1½”) inch penetration. The deck ledger must be protected to prevent moisture from entering the home’s wall system and properly flashed at the top of the ledger board. REQUIRED INSPECTIONS: 1. Footings: after the holes are dug, but PRIOR TO POURING CONCRETE!!

2. Framing, when less than 30” high and prior to deck board placement. 3. Final: when the structure has been completed. GENERAL NOTES: 1. The stamped, approved plans and survey shall be kept on the job until the final inspection has been made. 2. The Inspection Record Card shall be placed on the outside exterior wall near the deck and shall remain posted until the final inspection has been made.

3. Call 952.447.9850 between 8:00 a.m. and 4:30 p.m. to arrange for an inspection. 4. Prior to digging, call Gopher State One Call at 811 to verify utility locations. Forty - eight (48) hour notice is required, excluding weekends and holidays.

ALLOW 24 HOURS FOR ALL INSPECTIONS!!

Page 5: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

Beam splices must be directly over posts, minimum of 1½” bearing.

Deck ledger boards must be secured and attached to the structure per table R507.2 and R507.2.1within this handout.

Joist hangers are required wherever joists do not have at least 1½” of bearing. (Exceptions: cantilevered ends.)

Galvanized connectors are required for footing to post, post to beam, and beam to joist connections.

Guards are required on all decks more than 30” above grade. Guards must be 36” minimum in height. Open guards must have intermediate rails or an ornamental pattern that a 4” sphere cannot pass through. Guards must be able to withstand 200 lbs. of applied pressure.

Stairways must be 36” between guards for the full length of the stairway.

The maximum rise is 7 ¾”, the minimum run is 10”. Treads, risers and nosing’s shall be consistent within 3/8”. Open risers on stairs with a total rise greater than 30” is not permitted to allow the passage of a 4” diameter sphere. A nosing not less than ¾ inch or greater than 1 ¼” shall be provided on stairways. Spiral stairs are to comply with Section R311.7.9.1.

Stairways require a guard not less than 34” in height from the nose of the treads. Open guards shall have intermediate rails or an ornamental pattern such that a sphere 4 3/8” in diameter cannot pass through. The triangular openings formed by the riser, tread and bottom rail of guards shall be such that a sphere 6” in diameter cannot pass through.

Handrails are required on stairs with four or more risers.

.

Page 6: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

Handrails must have a continuous graspable surface and be 34” to 38” above the tread nosing and run the full length of the stairs with ends returned. Handrails shall have a space of not less than 1½” between the handrail and the wall or guard. The handrails shall be not less than 1¼” or more than 2” in diameter.

Structural members of exterior decks must be cedar, redwood, treated wood or an approved composite material.

Hangers, connectors and fasteners used in conjunction with ACQ treated lumber are required to be ACQ compatible.

Special designs or engineering may be required for a 3-season porch or if spas/whirlpool tubs will be placed/located on decks.

Revised plan review fees shall be incurred in the event an additional plan review becomes necessary due to revised building plans.

Alternative footing designs, such as Diamond Pier footings, will be evaluated on an individual basis.

4x4” posts (when used for rails and guards) may only be notched a maximum of 7/8 of an inch. 6x6” posts (when used for rails and guards) may be notched up to ½ of the thickness of the post.

Joists may only be cantilevered a maximum of 2 feet. Beams may only be

cantilevered a maximum of 1 foot.

Decks cannot bear on cantilevered floors. Additional framing will be required.

Page 7: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

DECK LEDGER REQUIREMENTS R507.1 Decks. Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads. Such attachment shall not be accomplished by the use of toenails or nails subject to withdrawal. Where positive connection to the primary building structure cannot be verified during inspection, decks shall be self-supporting. For decks with cantilevered framing members, connections to exterior walls or other framing members, shall be designed and constructed to resist uplift resulting from the full live load specified in Table R301.5 acting on the cantilevered portion of the deck. R507.2 Deck ledger connection to band joist. For decks supporting a total design load of 50 pounds per square foot (2394 Pa) [40 pounds per square foot (1915 Pa) live load plus 10 pounds per square foot (479 Pa) dead load], the connection between a deck ledger of pressure-preservative-treated Southern Pine, incised pressure-preservative-treated Hem-Fir or approved decay-resistant species, and a 2-inch (51 mm) nominal lumber band joist bearing on a sill plate or wall plate shall be constructed with 1/2-inch (12.7 mm) lag screws or bolts with washers in accordance with Table R507.2. Lag screws, bolts and washers shall be hot-dipped galvanized or stainless steel. TABLE R507.2 FASTENER SPACING FOR A SOUTHERN PINE OR HEM-FIR DECK LEDGER AND A 2-INCH-NOMINAL SOLID-SAWN SPRUCE-PINE-FIR BAND JOISTc, f, g (Deck live load = 40 psf, deck dead load = 10 psf)

JOIST SPAN 6′ and less 6′ 1″ to 8′ 8′ 1″ to 10′ 10′ 1″ to 12′ 12′ 1″ to 14′ 14′ 1″ to 16′ 16′ 1″ to 18′

Connection details On-center spacing of fastenersd, e 1/2 “ diameter lag screw with 15/32 “ maximum sheathinga 30 23 18 15 13 11 10 1/2 “ diameter bolt with 15/32 “ maximum sheathing 36 36 34 29 24 21 19 1/2 “ diameter bolt with 15/32 “ maximum sheathing and 1/2 “ stacked washersb, h 36 36 29 24 21 18 16

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. 1 pound per square foot = 0.0479 kPa.

a. The tip of the lag screw shall fully extend beyond the inside face of the band joist.

b. The maximum gap between the face of the ledger board and face of the wall sheathing shall be 1/2 inch.

c. Ledgers shall be flashed to prevent water from contacting the house band joist.

d. Lag screws and bolts shall be staggered in accordance with Section R507.2.1.

e. Deck ledger shall be minimum 2 × 8 pressure-preservative-treated No. 2 grade lumber, or other approved materials as established by standard engineering practice.

f. When solid-sawn pressure-preservative-treated deck ledgers are attached to a minimum 1-inch-thick engineered wood product (structural composite lumber, laminated veneer lumber or wood structural panel band joist), the ledger attachment shall be designed in accordance with accepted engineering practice.

g. A minimum 1 × 91/2 Douglas Fir laminated veneer lumber rim board shall be permitted in lieu of the 2-inch nominal band joist.

h. Wood structural panel sheathing, gypsum board sheathing or foam sheathing not exceeding 1 inch in thickness shall be permitted. The maximum distance between the face of the ledger board and the face of the band joist shall be 1 inch.

Page 8: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

R507.2.1 Placement of lag screws or bolts in deck ledgers and band joists. The lag screws or bolts in deck ledgers and band joists shall be placed in accordance with Table R507.2.1 and Figures R507.2.1(1) and R507.2.1(2). TABLE 507.2.1 PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS

MINIMUM END AND EDGE DISTANCES AND SPACING BETWEEN ROWS

TOP EDGE BOTTOM EDGE ENDS ROW SPACING

Ledgera 2 inchesd 1/4 inch 2 inchesb 15/8 inchesb

Band Joistc 3/4 inch 2 inches 2 inchesb 15/8 inchesb

For SI: 1 inch = 25.4 mm.

a. Lag screws or bolts shall be staggered from the top to the bottom along the horizontal run of the deck ledger in accordance with Figure R507.2.1(1).

b. Maximum 5 inches.

c. For engineered rim joists, the manufacturer’s recommendations shall govern.

d. The minimum distance from bottom row of lag screws or bolts to the top edge of the ledger shall be in accordance with Figure R507.2.1(1).

FIGURE R507.2.1(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS

Page 9: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

Page 10: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

Page 11: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019

Page 12: DECK HANDOUT - Updated 2019'hfn ohgjhu erdugv pxvw eh vhfxuhg dqg dwwdfkhg wr wkh vwuxfwxuh shu wdeoh 5 dqg 5 zlwklq wklv kdqgrxw -rlvw kdqjhuv duh uhtxluhg zkhuhyhu mrlvwv gr qrw

DECK HANDOUT - Updated 2019