deploying a point-to-(multi)point backhaul network - engenius · point-to-(multi)point backhaul...

21
Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 1 of 21 Deploying a Point-to-(Multi)Point Backhaul Network Jason D. Hintersteiner, CWNE #171 Gabriel Reyes Field Application Engineering, EnGenius Technologies, Inc. This document summarizes the procedure for configuring and deploying a point-to-point (PTP) or point- to-multipoint (PMP) backhaul network utilizing EnGenius hardware. In this document, a wireless link is defined as a wireless connection between a root node and one (or more) remote nodes. The wireless link uses a technology called Wireless Distribution System (WDS) bridging, which dedicates a radio to communicate with one or more other radios, specified by the MAC address of the remote radio(s). When in WDS bridge mode, the radio cannot be simultaneously used for client access. All Layer 2 traffic parameters, most especially MAC address of downstream clients and VLAN tags, are encapsulated and preserved across the link. Point-to-(Multi)Point Overview Typically, wireless links are used for outdoor / multi-building applications, so the typical deployment uses outdoor access points with directional antennas. Sometimes, omni-directional antennas can be used at the root node, if multiple remote nodes are deployed in different directions. An example of this is shown in Figure 1. Figure 1: Depiction of a point-to-multipoint wireless link. Indoor deployments of WDS Bridge links are done in scenarios where installing Ethernet or fiber cabling runs is either impossible or impractical, but power at each of the remote AP locations is available. It is

Upload: buikhue

Post on 27-Mar-2019

227 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 1 of 21

Deploying a Point-to-(Multi)Point Backhaul

Network

Jason D. Hintersteiner, CWNE #171

Gabriel Reyes

Field Application Engineering, EnGenius Technologies, Inc.

This document summarizes the procedure for configuring and deploying a point-to-point (PTP) or point-

to-multipoint (PMP) backhaul network utilizing EnGenius hardware.

In this document, a wireless link is defined as a wireless connection between a root node and one (or

more) remote nodes. The wireless link uses a technology called Wireless Distribution System (WDS)

bridging, which dedicates a radio to communicate with one or more other radios, specified by the MAC

address of the remote radio(s). When in WDS bridge mode, the radio cannot be simultaneously used for

client access. All Layer 2 traffic parameters, most especially MAC address of downstream clients and VLAN

tags, are encapsulated and preserved across the link.

Point-to-(Multi)Point Overview Typically, wireless links are used for outdoor / multi-building applications, so the typical deployment uses

outdoor access points with directional antennas. Sometimes, omni-directional antennas can be used at

the root node, if multiple remote nodes are deployed in different directions. An example of this is shown

in Figure 1.

Figure 1: Depiction of a point-to-multipoint wireless link.

Indoor deployments of WDS Bridge links are done in scenarios where installing Ethernet or fiber cabling

runs is either impossible or impractical, but power at each of the remote AP locations is available. It is

Page 2: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 2 of 21

best practice to utilize the 5 GHz band for wireless link applications, to take advantage of fewer sources

of interference from access points on the 2.4 GHz band as well as the larger channel selection and capacity

of 40 MHz channels on the 5 GHz band with 802.11n technology (e.g. EnStation5), and 80 MHz channels

on the 5 GHz band with 802.11ac technology (e.g. EnStationAC). The use of the 2.4 GHz band for wireless

links should be reserved only for scenarios where the property is isolated from remote interference,

where there is no co-located Wi-Fi coverage, and where there may be trees or other objects that partially

obstruct the Fresnel zone of the path (e.g. a farm or nursery utilizing remote cameras for surveillance).

By convention, the root node is defined as the upstream side of the link (i.e. towards demarc on the

property) and the remote / slave node is defined as the downstream side of the link (i.e. towards the

remote AP and/or camera). Unlike other vendors, however, there is no distinction in the EnGenius

hardware – both sides of the link are configured in the same manner.

A typical WDS Bridge link is shown in Figure 2. Parallel (i.e. point-to-multipoint) WDS bridge links are

shown in Figure 3.

Figure 2: Logical network diagram of a point-to-point link.

Page 3: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21

Figure 3: Logical network diagram of a point-to-multipoint link.

In larger deployments, wireless links can be daisy-chained / relayed in series, as shown in Figure 4. In this

scenario, a wireless link shall connect the demarc building to an intermediate building (“hub”), and then

one or more additional wireless links shall connect the hub to another remote location. This technique is

useful at properties where all of the remote locations do not have direct line of sight to the demarc, and/or

where the number of backhaul links need to be physically spread out across multiple buildings.

Figure 4: Logical network diagram of a serial point-to-point link.

When only one or two devices are connected on the remote end to a slave node, a PoE switch is not

required and the devices can be linked through the PoE (802.3af) pass-through port on the EnStationACs

Page 4: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 4 of 21

secondary LAN port, as shown in Figure 6. Note that the EnStationAC itself is powered via PoE+ (802.3at),

which can be supplied either by the enclosed PoE+ injector or a PoE+ (802.3at) switch.

Figure 5: Connecting a PoE (802.3af) device such as a remote IP camera to the secondary LAN port of an EnStationAC.

For the older EnStation2 (2.4 GHz 802.11n) and EnStation5 (5 GHz 802.11n) products, remote powered

devices like IP cameras can be connected by cross-connecting the data ports on PoE injectors. Examples

of this are shown in Figure 6 and Figure 7. Note that the EnStation2 and EnStation5 require proprietary

PoE injectors (24V) that come with the access points. Additionally, the EnStation2 / EnStation5 have an

auxiliary Ethernet interface which can be used to connect up to two devices at the remote end without a

switch, as shown in Figure 8 and Figure 9, or to connect up to two devices without a switch at an

intermediate relay location, as shown in Figure 10.

Figure 6: Cross-connecting PoE injectors for a single remote device (e.g. remote IP camera).

Page 5: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 5 of 21

Figure 7: Wiring configuration for one AP per slave backhaul link.

Figure 8: Wiring configuration for two APs per slave backhaul link.

Network(Data only)

AP/Bridge(Data + Power)

Slave Node

Remote Access Point

Primary Interface

Network(Data only)

AP/Bridge(Data + Power)

SecondaryInterface

Network(Data only)

AP/Bridge(Data + Power)

Network(Data only)

AP/Bridge(Data + Power)

Slave Node

Remote Access Points

PrimaryInterface

Network(Data only)

AP/Bridge(Data + Power)

Page 6: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 6 of 21

Figure 9: Wiring configuration for two cameras per slave backhaul link.

Figure 10: Wiring configuration for two cameras per intermediate relay point backhaul link without a PoE switch.

In general, a dedicated radio shall be used in a design of a wireless link, connecting to remote access points

or cameras. In instances where only a single remote AP and/or camera is required, a dual-radio access

point can be used with the 5 GHz radio is dedicated to the WDS bridge link. Note that Wi-Fi clients will

only be served on the 2.4 GHz radio in this case, as shown in Figure 11.

Page 7: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 7 of 21

Figure 11: Logical design diagram showing a single remote AP connected via WDS on its 5 GHz radio. Clients are served on the

2.4 GHz band only for such APs.

Figure 12: Logical design diagram showing an omni-directional AP at the root location, for connecting multiple remote locations

that do not fall within the 18o directional envelope of a standard EnStation. Clients may optionally be served with Wi-Fi on the

2.4 GHz band from such omni-directional APs.

Page 8: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 8 of 21

Configuration Best Practices For point-to-multipoint networks, a maximum of eight remote nodes (EnStationAC) or four remote notes

(EnStation2 / EnStation5) can be configured to connect to a root node. It is generally best practice to keep

the number of remote / slave nodes to one or two per wireless link. This is done for several reasons:

- It limits the total amount of traffic going over any particular wireless link

- It minimizes the effect of an outage due to equipment failure

- It leaves some design margin in case additional locations for remote access are required

In the absence of external interference for short distance links (under ½ mile), the following sustained

data throughputs are achievable:

- EnStationAC (802.11ac, 80 MHz channel): 400 Mbps

- EnStation5 (802.11n, 40 MHz channel): 80 Mbps

- EnStation2 (802.11n, 20 MHz channel): 40 Mbps

At larger distances, the signal gets weaker and the wireless data rates get slower, leading to a lower overall

data throughput. Signal is measured by the receive signal strength indicator (RSSI), which indicates how

well a particular radio can hear the remote connected client radios. For point-to-(multi)point applications,

the optimal RSSI on each end of the wireless link is between -40 dBm and -50 dBm to achieve the highest

possible data rates.

Setting Appropriate Transmit Power The best practice is to pre-configure the radios with a transmit power of 17 dBm and validate that a link

is properly established (which serves to validate security and MAC address settings as well). Once the

access points are physically mounted in place, look at the RSSI readings on each radio and adjust the

transmit power settings on each side of the link up or down to get the RSSI to within the -40 dBm to -50

dBm range.

If the signal strength is greater than -35 dBm (typical for wireless links under 50 feet), then the electronic

amplifiers get saturated because the signal is too strong, which degrades throughput performance. In

such scenarios, turning down the power to minimum (11 dBm) may be insufficient, and if so we

recommend purposely misaligning the antennas.

If the signal strength is less than -75 dBm (typical for very long distance shots over 4 miles), it may be

difficult to sustain a link reliably or to achieve high throughputs, especially in the presence of external

interference. For long distance shots, EnGenius recommends using laser tooling to optimize the antenna

alignment so as to maximize the signal.

Setting Appropriate Channels In non-rural environments, the entire 2.4 GHz band (channels 1 – 11) and the UNII-1 and UNII-3 portions

of the 5 GHz band (channels 36 – 48 and 149 – 165) are commonly used by dual-band access points for

Wi-Fi. These Wi-Fi access points can create significant co-channel interference (CCI) with point-to-

(multi)point links and degrade their performance. It is therefore recommended that wireless point-to-

point links be established on the 5 GHz band and that channels are restricted to the UNII-2 and UNII-2e

portions of the band (channels 52-64 and 100-140). When utilizing multiple point-to-(multipoint) links,

please keep the neighboring channels independent and use an alternating sequence to maximize their

Page 9: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 9 of 21

separation. The following alternating scheme for adjacent / co-located wireless links is recommended.

Note that halving the channel size will halve the maximum data capacity of the link, but will double the

number of independent channels:

- 80 MHz (EnStationAC): 100, 52, 116

- 40 MHz (EnStation5/EnStationAC): 52, 100, 116, 132, 60, 108, 124

- 20 MHz (EnStation5/EnStationAC): 52, 100, 116, 132, 60, 108, 124, 56, 104, 120, 136, 64, 112, 128

Considerations for Video Surveillance Applications Point-to-(multi)point links are commonly used for surveillance applications, where one or multiple IP

cameras need to be positioned at a remote location. When designing such applications, it is important

that the bandwidth requirements per camera are understood, so as not to exceed the capacity of the

backhaul link. It is therefore important to consider the quantity of cameras, number of pixels per camera,

and frame rate. Furthermore, H.264 (or better) encoding should always be used to maximize video data

compression when utilizing wireless links.

When deploying IP cameras for remotely located video surveillance across a property, it is best practice

to evaluate and explicitly quantify the average data rate per camera, which is based on number of pixels,

frame rate, and compression scheme (H.264 or better encoding is always recommended when using

wireless links). The total number of cameras per wireless link should be limited to 50% - 60% of the total

capacity of the link. This ensures that there will be sufficient bandwidth on the wireless link in case of link

degradation due to external interference effects, as well as leaving some design margin in case additional

cameras are added to the video surveillance design at the last minute or at a future point in time.

When calculating the throughput link budget of a wireless point-to-(multi)point system, it is important to

remember that all downstream hops have an additive effect on the total upstream throughput. An

example of this is shown in Figure 13.

Figure 13: Example link budget calculation for multiple point-to-point shots in series.

Page 10: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 10 of 21

EnGenius Access Point Models Supporting Point-to-(Multi)Point All EnGenius Electron APs can be configured in WDS bridge mode to establish point-to-(multi)point links.

For most applications, using models with internal directional antennas will be appropriate, though in some

cases, the use of omni-directional antennas is appropriate at the root to reach remote locations in

opposite directions. The full list of EnGenius APs that can be configured in WDS Bridge mode are shown

in Table 1. The models highlighted in green are specifically designed for WDS Bridge applications and thus

recommended for most applications, though can also be operated as single-band access points.

Table 1: List of EnGenius Access Points capable of WDS bridge mode.

Technology MIMO

EnGenius Electron

(Standalone APs)

Indoor Outdoor

802.11n

2.4 GHz only 2x2:2

EAP300

EAP350

ECB350*

EnStation2†

ENS202†

ENS202EXT*

ENH202†

ENH220EXT*

802.11n

5 GHz only 2x2:2

EnStation5†

ENS500†

ENS500EXT*

ENH500†

802.11n

dual-band

2x2:2 EAP600 ENH710EXT*

3x3:3 ENH900EXT*

802.11ac

wave 1

5 GHz only

2x2:2 EnStationAC†

802.11ac

wave 1

dual-band

2x2:2 EAP1200H

ECB1200* ENS1200

3x3:3 EAP1750H

ECB1750*

ENS1750

ENH1750EXT*

* Denotes AP models with external antennas

† Denotes AP models with internal direcOonal antennas

Design Example #1: RV Park Figure 14 shows an RV park using EnGenius equipment to supply managed Wi-Fi. EnGenius Neutron

EWS860 outdoor access points are located at all of the poles with red pins (other poles in the park are

shown with yellow pins). There are approximately 40 client devices per access point during peak usage

times. All access points require point-to-multipoint backhaul to the main distribution frame containing

the AP controller, router, and Internet feed, which is in the Registration building at the lower right corner

of the property. There is fiber running to one distribution pole, with all other links being wireless utilizing

EnStationAC.

Page 11: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 11 of 21

Figure 14: Design example of a point-to-multipoint network spanning an RV park to provide Wi-Fi and wireless backhaul.

For channelization on the 5 GHz band, the access points are all set with static 40 MHz channels on UNII-

1 (36 – 48) and UNII-3 (149 – 161). The point-to-multipoint links are all set with static 80 MHz channels

on UNII-2 (52 – 64) and UNII-2e (100 – 140) bands to maximize capacity. This is shown in Table 2.

Page 12: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 12 of 21

Table 2: AP locations with individual static channel and power settings per band for RV Park application.

Design Example #2: Urban Surveillance The following is a surveillance application at an apartment complex in Brooklyn, NY. There are 59

apartment buildings, each equipped with 16 cameras and an NVR. All buildings have line-of-sight to the

main distribution frame (MDF). A central security operations center is located in the MDF building, with

the requirement to be able to view multiple cameras across the complex. A series of point-to-multipoint

links are established from the main building to connect to the 58 other buildings, as shown in Figure 15.

Location AP Model2.4 GHz

Channel

2.4 GHz

Channel

Size

2.4 GHz

Power

5 GHz

Channel

5 GHz

Channel

Size

5 GHz

Power

Access Points

Registration* EWS860AP 1 20 MHz 20 dBm 36 40 MHz 23 dBm

Pole at Distribution* EWS860AP 6 20 MHz 20 dBm 149 40 MHz 23 dBm

Pole at 7 / 8 EWS860AP 11 20 MHz 20 dBm 157 40 MHz 23 dBm

Bath House 1* EWS860AP 6 20 MHz 20 dBm 36 40 MHz 23 dBm

Pole at 70/71 EWS860AP 1 20 MHz 17 dBm 44 40 MHz 23 dBm

Pole at 98 / 99 EWS860AP 11 20 MHz 20 dBm 149 40 MHz 23 dBm

Pole at 135 / 136 EWS860AP 1 20 MHz 17 dBm 157 40 MHz 23 dBm

Pole at 168* EWS860AP 6 20 MHz 20 dBm 36 40 MHz 23 dBm

Pole at 174 / 175 EWS860AP 11 20 MHz 20 dBm 44 40 MHz 23 dBm

Pole at 226* EWS860AP 6 20 MHz 20 dBm 36 40 MHz 23 dBm

Pole at 336* EWS860AP 1 20 MHz 20 dBm 149 40 MHz 23 dBm

Pole at 411 / 412 EWS860AP 1 20 MHz 17 dBm 44 40 MHz 23 dBm

Pole at 424 / 425 EWS860AP 1 20 MHz 20 dBm 149 40 MHz 23 dBm

Pole at 342 EWS860AP 11 20 MHz 20 dBm 157 40 MHz 23 dBm

Pole at C1 / C2 EWS860AP 1 20 MHz 17 dBm 157 40 MHz 23 dBm

Pole At Pet Area EWS860AP 6 20 MHz 20 dBm 36 40 MHz 23 dBm

Barn EWS860AP 11 20 MHz 14 dBm 157 40 MHz 23 dBm

Point-to-(Multi)Point Links

Registration (facing Barn) EnStationAC N/A N/A N/A 100 80 MHz 17 dBm

Barn (facing Reg) EnStationAC N/A N/A N/A 100 80 MHz 17 dBm

Barn (facing pole 226) EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Barn (facing pole 168) EnStationAC N/A N/A N/A 52 80 MHz 17 dBm

Pole 226 (facing Barn) EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole 168 (facing Barn) EnStationAC N/A N/A N/A 52 80 MHz 17 dBm

Distro (facing pole 98/99) EnStationAC N/A N/A N/A 52 80 MHz 17 dBm

Distro (facing Bath House 1) EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole 98/99 (facing Distro) EnStationAC N/A N/A N/A 52 80 MHz 17 dBm

Bath House 1 (facing Distro) EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Registration (facing Truck Wash) EnStationAC N/A N/A N/A 52 80 MHz 17 dBm

Truck Wash (facing Barn) EnStationAC N/A N/A N/A 52 80 MHz 17 dBm

Truck Wash (facing Park) EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole at 7 / 8 EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole at 70/71 EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole at 135 / 136 EnStationAC N/A N/A N/A 52 80 MHz 17 dBm

Pole at 174 / 175 EnStationAC N/A N/A N/A 52 80 MHz 17 dBm

Pole at 411 / 412 EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole at 424 / 425 EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole at 336 EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole at 342 EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole at C1 / C2 EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Pole At Pet Area EnStationAC N/A N/A N/A 116 80 MHz 17 dBm

Page 13: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 13 of 21

Figure 15: Design example of a point-to-multipoint network spanning rooftops in an urban environment for surveillance.

Because of the data requirements, the use of 80 MHz channels was required. A shielded metal tower

was constructed to keep the neighboring EnStationAC units on the roof of the MDF isolated from each

other so that channels could be re-used, as shown in Figure 16.

Figure 16: Custom tower used to isolate neighboring EnStationACs on the roof of the MDF.

Page 14: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 14 of 21

As the buildings were brick and the links were all above the roof line, the interference from Wi-Fi in the

apartment units was minimal so channels 36 and 149 were also used in this case. The complete

channelization plan is shown in Table 3.

Table 3: AP locations with individual static channel and power settings per band for urban surveillance application.

Location AP ModelAntenna

DirectionGroup

5 GHz

Channel

5 GHz

Channel

Size

5 GHz

Power

Point-to-(Multi)Point Links - Root

MDF - 1368 New York Ave EnStationAC Tower SW-R 1 36 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower SW-L 2 100 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower W-R 3 149 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower W-L 4 52 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower NW-R 5 116 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower NW-L 6 36 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower N-R 7 100 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower NW-R 8 149 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower NW-L 9 52 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower W-R 10 116 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower W-L 11 36 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower SW-R 12 100 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower SW-L 13 149 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower S-R 14 52 80 MHz 17 dBm

MDF - 1368 New York Ave EnStationAC Tower S-L 15 116 80 MHz 17 dBm

Point-to-(Multi)Point Links - Remote

1404 New York Ave EnStationAC N 1 36 80 MHz 17 dBm

1402 New York Ave EnStationAC N 1 36 80 MHz 17 dBm

1416 New York Ave EnStationAC N 1 36 80 MHz 17 dBm

1414 New York Ave EnStationAC N 1 36 80 MHz 17 dBm

1406 New York Ave EnStationAC NNE 2 100 80 MHz 17 dBm

1408 New York Ave EnStationAC NNE 2 100 80 MHz 17 dBm

1410 New York Ave EnStationAC NNE 2 100 80 MHz 17 dBm

1412 New York Ave EnStationAC NNE 2 100 80 MHz 17 dBm

1366 New York Ave EnStationAC E 3 149 80 MHz 17 dBm

1364 New York Ave EnStationAC E 3 149 80 MHz 17 dBm

1362 New York Ave EnStationAC E 3 149 80 MHz 17 dBm

3101 Foster Ave EnStationAC E 3 149 80 MHz 17 dBm

3103 Foster Ave EnStationAC ESE 4 52 80 MHz 17 dBm

3104 Newkirk Ave EnStationAC ESE 4 52 80 MHz 17 dBm

1360 New York Ave EnStationAC ESE 4 52 80 MHz 17 dBm

1358 New York Ave EnStationAC ESE 4 52 80 MHz 17 dBm

3102 Newkirk Ave EnStationAC SE 5 116 80 MHz 17 dBm

1356 New York Ave EnStationAC SE 5 116 80 MHz 17 dBm

1354 New York Ave EnStationAC SE 5 116 80 MHz 17 dBm

Location AP ModelAntenna

DirectionGroup

5 GHz

Channel

5 GHz

Channel

Size

5 GHz

Power

1352 New York Ave EnStationAC SSE 6 36 80 MHz 17 dBm

1350 New York Ave EnStationAC S 6 36 80 MHz 17 dBm

1372 New York Ave EnStationAC S 6 36 80 MHz 17 dBm

1370 New York Ave EnStationAC S 6 36 80 MHz 17 dBm

1351 New York Ave EnStationAC SW 7 100 80 MHz 17 dBm

1353 New York Ave EnStationAC SW 7 100 80 MHz 17 dBm

1355 New York Ave EnStationAC SW 7 100 80 MHz 17 dBm

3303 Foster Ave EnStationAC SW 7 100 80 MHz 17 dBm

3305 Foster Ave EnStationAC SSW 8 149 80 MHz 17 dBm

3401 Foster Ave EnStationAC SSW 8 149 80 MHz 17 dBm

3403 Foster Ave EnStationAC SSW 8 149 80 MHz 17 dBm

3405 Foster Ave EnStationAC SSW 8 149 80 MHz 17 dBm

3301 Foster Ave EnStationAC W 9 52 80 MHz 17 dBm

3501 Foster Ave EnStationAC SSW 9 52 80 MHz 17 dBm

3503 Foster Ave EnStationAC SSW 9 52 80 MHz 17 dBm

3505 Foster Ave EnStationAC W 9 52 80 MHz 17 dBm

1405 Brooklyn Ave EnStationAC NNW 10 116 80 MHz 17 dBm

1402 Brooklyn Ave EnStationAC NNW 10 116 80 MHz 17 dBm

1404 Brooklyn Ave EnStationAC NNW 10 116 80 MHz 17 dBm

1406 Brooklyn Ave EnStationAC NNW 10 116 80 MHz 17 dBm

1408 Brooklyn Ave EnStationAC NNW 11 36 80 MHz 17 dBm

1410 Brooklyn Ave EnStationAC NNW 11 36 80 MHz 17 dBm

1421 Brooklyn Ave EnStationAC NNW 11 36 80 MHz 17 dBm

1425 New York Ave EnStationAC NNW 11 36 80 MHz 17 dBm

1416 Brooklyn Ave EnStationAC NNW 12 100 80 MHz 17 dBm

1418 Brooklyn Ave EnStationAC NNW 12 100 80 MHz 17 dBm

1420 Brooklyn Ave EnStationAC NNW 12 100 80 MHz 17 dBm

1407 New York Ave EnStationAC NNW 12 100 80 MHz 17 dBm

1412 Brooklyn Ave EnStationAC NNW 13 149 80 MHz 17 dBm

1403 New York Ave EnStationAC NNW 13 149 80 MHz 17 dBm

1405 New York Ave EnStationAC NNW 13 149 80 MHz 17 dBm

1409 New York Ave EnStationAC NNW 13 149 80 MHz 17 dBm

1414 Brooklyn Ave EnStationAC NNW 14 52 80 MHz 17 dBm

1401 New York Ave EnStationAC NNW 14 52 80 MHz 17 dBm

1411 New York Ave EnStationAC NNW 14 52 80 MHz 17 dBm

1413 New York Ave EnStationAC NNW 14 52 80 MHz 17 dBm

1415 New York Ave EnStationAC NNW 15 116 80 MHz 17 dBm

1417 New York Ave EnStationAC NNW 15 116 80 MHz 17 dBm

1419 New York Ave EnStationAC NNW 15 116 80 MHz 17 dBm

Page 15: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 15 of 21

Configuring the Access Points for Point-to-(Multi)Point Applications To create a wireless link, the radio on the access must be configured for “WDS Bridge” mode. Once that

is done, the MAC address of the access point other side of the wireless link. For point-to-multipoint

applications, the MAC addresses of the multiple slave nodes shall all be specified on the root node. On

the slave nodes, only the MAC address of the root node is listed.

The configuration procedure is as follows:

(1) Log into the Access Point

a. http://192.168.1.1

b. Default Username: admin

c. Default Password: admin

(2) Go to the Operation Mode screen.

a. Set the access point into WDS mode (for dual band APs, do this for the 5 GHz radio)

b. Set the Country / Region

c. Provide a unique name for the AP

Figure 17: Operation Mode screen [EnStation2].

(3) Go to the IP Settings screen. Provide a unique static IP address for the AP on your LAN.

Page 16: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 16 of 21

Figure 18: IP Settings screen [EnStation2].

(4) Go to the WDS Link Settings screen.

a. Security Type: AES (WEP and TKIP are deprecated. Do not use.)

b. AES Passphrase: <8-64 characters> (Choose a passphrase. Must match on both sides of

link.)

c. MAC Addresses: Enable and enter the MAC address(es) of the remote access points.

(Note, only the root node should have multiple MAC address listings for up to 4 slave nodes

when creating a point-to-multipoint link. When doing links in serial, use a separate slave

node for the first link and co-located root node on a different channel for the second link.)

Page 17: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 17 of 21

Figure 19: WDS Link Settings screen [EnStation2].

Figure 20: WDS Link Settings of a 5 GHz root node wireless point-to-multipoint link in WDS Bridge mode [EAP1750H].

(5) Go to the Wireless Network screen.

a. Set wireless mode: 802.11n or 802.11n/ac only (Disable 802.11a)

b. Channel HT mode:

i. 2.4 GHz radios: 20 MHz

Page 18: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 18 of 21

ii. 5 GHz 802.11n radios: 40 MHz

iii. 5 GHz 802.11ac radios: 80 MHz

c. Extension Channel: <ignore> (This is not relevant for 20 MHz channels, and will be

selected automatically for 40 MHz / 80 MHz channels

d. Channel / Frequency: <unique> (Choose a unique, non-overlapping channel for your band.

In large deployments, channels can be re-used but make sure they are not on neighboring

/ co-located links. Also be sure to not conflict with your AP channels if deploying

802.11n/ac access points. If EnGenius has supplied a design, a recommended channel

allocation is generally included. These should be considered “starting points”, as

external Wi-Fi sources present at the site may necessitate selecting alternate channels

with less interference.

i. 2.4 GHz Channels (20 MHz): 1, 6, 11

ii. 5 GHz 802.11n Channels (40 MHz): 36, 44, 52, 60, 100, 108, 116, 124, 132, 1401,

149, 157

iii. 5 GHz 802.11ac Channels (80 MHz): 36, 52, 100, 116, 1321, 149

Figure 21: Wireless Network Settings screen [EnStation2].

1 Channel 140 (40 MHz) or 132 (80 MHz) is only available if channel 144 is available on the access point.

Page 19: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 19 of 21

Figure 22: 5 GHz portion of wireless Network Settings screen [ENH1750EXT].

(6) Go to the Wireless Advanced Setting screen. Most settings here should be left on default unless

you are specifically advised to change them by an EnGenius Field Application Engineer.

a. Data Rate: Auto [default]. This allows the AP to dynamically adjust the data rate based

on the strength and condition of the wireless link.)

b. Transmit Power: 17 dBm [initial]. Must be set on both sides of link based on distance and

any obstructions. When the link is established, the RSSI of the other side should be

between -65 dBm to -40 dBm. If the signal is weaker than -65 dBm, the data rate will not

be optimal and thus you will not get the full capacity of the link. If the signal is stronger

than -35 dBm, then the signal is too strong, the amplifiers in the AP will be saturated, and

the link quality will degrade. For very short links (<< 50 feet), minimal power level of 11

dBm should be set and potentially the links may need to be purposely misaligned to get

the power level below -35 dBm.

c. RTS/CTS Threshold: 2346 [default]. This is a protection mechanism to allow newer APs to

talk to older 802.11 clients. Not used in WDS.

d. Distance: 1 km [default]. For very long links, additional delays for message

acknowledgements are sometimes required. For most applications, this can be left at

default.

e. Aggregation: Enable, 32 Frames, 50000 bytes [default]. Frame aggregation is a

mechanism used by 802.11n/ac to reduce overhead. Leave enabled at default settings.

f. Wireless Traffic Shaping: Disabled [default]. This provides bandwidth limits per SSID.

Generally we want to maximize the capacity of the link, so leave this disabled.

Page 20: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 20 of 21

Figure 23: Wireless Advanced Settings screen [EnStation2].

To see if the link is established and to verify the RSSI values, click on the “WDS Link List” tab (or

“Connections” tab on 802.11ac models).

Figure 24: Connections / WDS Link List screen to view list of connected access points [EnStationAC].

Page 21: Deploying a Point-to-(Multi)point Backhaul Network - EnGenius · Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 3 of 21 Figure 3: Logical network diagram of a point-to-multipoint

Point-to-(Multi)point Backhaul Network [h266] © 2014-2016 Page 21 of 21

Powering the Wireless Links The EnStationAC is powered via 802.3at, and can be powered from any standard PoE+ (802.3at) switch or

injector. A PoE+ injector is included with the hardware.

All of the outdoor 802.11n access points with internal directional antennas (e.g. EnStation2, EnStation5,

ENS500, ENS202) are powered via 24V passive PoE injectors, instead of standard 802.3af (i.e. PoE at 48V,

up to 15.4W) or 802.3at (i.e. PoE+ at 48V, up to 30W) used to power network devices, such as access

points and cameras. A 24V PoE injector is included with the hardware.

EnGenius offers the EPD4824, which is a 48V PoE active to 24V passive PoE converter. This converter is

powered from of a conventional PoE / PoE+ network switch, and thus does not require a separate power

cord for the PoE injector. For applications where remote PoE switches are deployed for APs and cameras,

the use of this converter for power is highly recommended.

Figure 25: EPD4824 converter to go from PoE 48V (802.3af) to PoE 24V (proprietary).

There is also a third party appliance, the POE24 from Digital Loggers, which provides an 8 port 24V PoE

injector with a web power switch for powering 24V devices in a 1U chassis. This appliance can be deployed

in demarc and hub locations where several 24V PTP/PMP access points are located. This device can be

configured to ping the IP address of the remote end of each link and power cycle the particular PoE port

if the link is detected as offline:

Spec sheet: http://www.digital-loggers.com/poe24spec.pdf

Web site: http://www.digital-loggers.com/poe24.html

Figure 26: Digital Loggers POE24 8 port 24V PoE injector.