detección lineal de temperatura o cable detector
TRANSCRIPT
A D D R E S S A B L E
L I N E A R H E A T D E T E C T I O N
▪ Innovations
▪ Solutions
▪ SupportLinear Heat Detection
Now for Use on ANY Addressable Panel
Just Add an Addressable Contact Monitor Module
Compatible with ANY Conventional Fire Alarm Panel
Better
Up to 10,000 Linear Feet (3,000m) of SafeCable per Zone
RF Tested up to 10,000 Linear Feet (3,000m)
Longer Spool Lengths Available
Farther
Lower Material Costs
Less Installation Time
No Expensive Linear Heat Detection Panels to Buy and Maintain
Lower Cost
Up to 10,000 Linear Feet per Zone
▪ Longer Runs
▪ Less Resistance
▪ Lower cost
Advanced Design Allows Up to 10,000 Linear Feet of SafeCableper Zone
Tri-Metallic Core Reduces Resistance to Only .05 ohms/ftResistance per Twisted Pair Wire
Designed to be Compatible with ALL Addressable andConventional Fire Alarm Control and Releasing Panels
Reduce Material and Installation Costs with Less Splicing,Longer Spool Lengths, and Easier Installation
Multiple alarm temperatures can be combined on the samezone
Total zone length replacement unnecessary after alarm
Pro
du
cts
Detection
Temperatures:
155 F (68 C)
172 F (78 C)
190 F (88 C)
220 F (105 C)
Nylon - UV protected for outdoor applications and extradurable for harsh industrial environments.
Polypropylene – For chemically harsh and causticenvironments such as wet benches.
GuideWire – For spanning distances up to 250 ft. (76m)with supports every 15 ft. (4.6m).
Up to 10,000 Linear Feet per Zone
▪ Longer Runs
▪ Less Resistance
▪ Lower cost
Detection
Temperatures:
155 F (68 C)
172 F (78 C)
190 F (88 C)
220 F (105 C)
TC155NG
Temperature
Nylon
Guidewire
Multiple Outer Coverings Available for Specific Hazards
Alarm Point Distance Locating
Up to 10,000 Linear Feet per Zone
▪ Longer Runs
▪ Less Resistance
▪ Lower cost
Detection
Temperatures:
155 F (68 C)
172 F (78 C)
190 F (88 C)
220 F (105 C)Alarm Point Distance Locating Displays in Both Feet and Meters
May be Used for Both Class “A” and “B” Applications
Only .05 ohms/ft resistance per Twisted Pair
▪ Longer Runs
▪ Less Resistance
▪ Lower cost
Pro
du
cts
SPACING AND TEMPERATURE
Temperature Rating UL, C-UL-US FM
155 F (68 C) 35’ (10.7m) 30’ (9.1m)
172 F (78 C) 35’ (10.7m) 30’ (9.1m)
190 F (88 C) 35’ (10.7m) 30’ (9.1m)
220 F (105 C) 35’ (10.7m) 25’ (7.6m)
35’ (10.7m)
17’6” (5.3m).7x
Area Spacing
Listed Spacing
▪ Any Panel
▪ Addressable
▪ ConventionalSystem Components
Co
mp
on
en
ts
▪ Any Panel
▪ Addressable
▪ ConventionalTypical System Configurations
ADDRESSABLE SYSTEM
CONFIGURATION
CONVENTIONAL SYSTEM
CONFIGURATION
Installation Accessories
▪ Mounting
▪ Connecting
▪ Splicing
Acc
ess
ori
es
Clamps, Clips, Ties, Mounts, Adhesive
Mounting
Junction Boxes and Fittings
Connecting
Terminal Blocks, Tapes, Sealers
Splicing
▪ Commercial
▪ Industrial
▪ UtilitiesFlexibility to Adapt to Your Environment
Addressable / Conventional Linear Heat Detection
▪ Any Panel
▪ Addressable
▪ Conventional
Linear Heat Detection
One Company, Five Great Products