development application · 2020. 8. 13. · development application pdplanpmtd-2020/009857...
TRANSCRIPT
![Page 1: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/1.jpg)
DEVELOPMENT APPLICATION
PDPLANPMTD-2020/009857
APPLICANT: Creative Homes Hobart
PROPOSAL: 4 Multiple Dwellings
LOCATION: 5 Jardinelle Road, ROKEBY
RELEVANT PLANNING SCHEME: Clarence Interim Planning Scheme 2015
ADVERTISING EXPIRY DATE: 31 August 2020
In addition to the Application Form(s), Certificate of Title(s) and any associated
consent documents the following information is available on request:
• Nil
The relevant plans and documents can be inspected at the Council offices, 38 Bligh
Street, Rosny Park, during normal office hours until 31 August 2020.
Any person may make representations about the application to the General
Manager, by writing to PO Box 96, Rosny Park, 7018 or by electronic mail to
[email protected]. Representations must be received by Council on or before
31 August 2020.
To enable Council to contact you if necessary, would you please also include a day
time contact number in any correspondence you may forward.
Any personal information submitted is covered by Council’s privacy policy, available
at www.ccc.tas.gov.au or at the Council offices.
![Page 2: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/2.jpg)
PROJECT ADDRESS: 5 JARDINELLE ROAD, ROKEBY
TITLE REFERENCE: VOLUME: FOLIO: 431
CLIENTS: Le Minh Trang Phan
DESIGNER: INGE BROWN, CC 6652
DRAWINGS: 01 PROPOSED SITE PLAN02 PROPOSED UNIT 1 FLOOR PLAN03 PROPOSED UNIT 1 ROOF PLAN04 PROPOSED UNIT 2 FLOOR PLAN05 PROPOSED UNIT 2 ROOF PLAN06 PROPOSED UNIT 3 FLOOR PLAN07 PROPOSED UNIT 3 ROOF PLAN08 PROPOSED UNIT 4 FLOOR PLAN09 PROPOSED UNIT 4 ROOF PLAN10 PROPOSED UNIT 1 ELEVATIONS11 PROPOSED UNIT 1 ELEVATIONS12 PROPOSED UNIT 2 ELEVATIONS13 PROPOSED UNIT 2 ELEVATIONS14 PROPOSED UNIT 3 ELEVATIONS15 PROPOSED UNIT 3 ELEVATIONS16 PROPOSED UNIT 4 ELEVATIONS17 PROPOSED UNIT 4 ELEVATIONS18 TYPICAL SECTION A-A19 TYPICAL WINDOW SCHEDULE
FLOOR AREAS:
SOIL CLASSIFICATION: PWIND CLASSIFICATION: N2CLIMATE ZONE: 7BUSHFIRE ATTACK LEVEL: N/AALPINE AREA: N/ACORROSION ENVIRONMENT: N/A
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
PER UNIT:
FLOOR AREA: 113.4 m²PORCH: 0.8 m²GARAGE: 24.8 m²
TOTAL AREA: 139.1 m²
![Page 3: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/3.jpg)
LOT 431, NO 5
PROPOSED SITE PLAN
NOTESBUILDER AND SUBCONTRACTORS TO VERIFY ALL DIMENSIONSAND LEVELS PRIOR TO THE COMMENCEMENT OF ANY WORK.GIVE 24 HOURS MINIMUM NOTICE WHERE AMENDMENTS AREREQUIRED TO DESIGN OF WORKING DRAWINGS. THESEDRAWINGS ARE TO BE READ IN CONJUNCTION WITHENGINEERS AND SURVEYORS DRAWINGS AND NOTES. DO NOTSCALE DRAWINGS.DIMENSIONS ARE TO TAKE PREFEREENCE OVER SCALE.BUILDING SPECIFICATION AND ENGINEERS DRAWINGS SHALLOVERRIDE ARCHITECTURAL DRAWINGS.
IMPORTANT NOTICE FOR ATTENTION OF OWNERTHE OWNERS ATTENTION IS DRAWN TO THE FACT THATFOUNDATIONS AND ASSOCIATED DRAINAGE IN ALL SITESREQUIRES CONTINUING MAINTENANCE TO ASSIST FOOTINGPERFORMANCE. ADVICE FOR FOUNDATION MAINTENANCE ISCONTAINED IN THE CSIRO BUILDING TECHNOLOGY FILE 18AND IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SITE INACCORDANCE WITH THIS DOCUMENT.
-THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALLOTHER DRAWINGS SHEETS, CONSULTANTS DRAWINGS,DOCUMENTS, SCHEDULES AND SPECIFICATIONS (ASAPPLICABLE).-THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALLSTORMWATER DRAINS, SEWER PIPES AND THE LIKE ARELOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDINGSFOOTING AND/OR SLAB EDGE BEAMS SO AS TO PREVENTGENERAL MOISTURE PENETRATION, DAMPNESS, WEAKENING &UNDERMINING OF ANY BUILDING AND ITS FOOTING SYSTEM.- LOCATION OF ALL EXISTING ONSITE SERVICES TO BECONFIRMED ONSITE PRIOR TO CONSTRUCTION
SOIL AND WATER MANAGEMENT NOTES:SITE TO BE VEGETATED AND PLANTED ACCORDING TO THEHOBART REGIONAL SOIL AND WATER MANAGEMENT CODEOF PRACTICE.
SITE TO BE DISTURBED AS MINIMALLY AS POSSIBLE, (I.E. ONLY
BUILDING, DRAINAGE AND IMMEDIATE ADJOINING AREAS).INSTALL ALL DRAINAGE LINES PRIOR TO PLACEMENT OF ROOFAND GUTTERING.CONNECT IMMEDIATELY ONCE DWELLING IS ROOFED.APPLY TEMPORARY COVERING (E.G. WATERPROOF BLANKETS,VEGETATION OR MULCH) TO ALL DISTURBED AREAS WHERECONSTRUCTION IS ONLY PARTIALLY COMPLETED, WHICH WILLREMAIN EXPOSED FOR A PERIOD OF 14 DAYS OR MORE.
PROTECT ANY NEARBY OR ON-SITE DRAINAGE PITS FROMSEDIMENT BY INSTALLING SEDIMENT TRAPS AROUND THEM.LIMIT ENTRY/EXIT TO ONE POINT AND STABILISE. INSTALLFACILITIES TO REMOVE DIRT/ MUD FROM VEHICLE WHEELSBEFORE THEY LEAVE THE SITE.
NOTEFINAL FFL'S AND DRIVEWAY GRADIENT TBC BYBUILDER AND TO COMPLY WITH BCA ANDAUSTRALIAN STANDARDS
IMPORTANT!SITE INFORMATION AS DRAWN ISAPPROXIMATE ONLY. FINAL SITEINFORMATION IS SUBJECT TO ADETAILED CONTOUR SURVEY BY
LICENSED SURVEYOR.
SOIL CLASSIFICATION:
WIND CLASSIFICATION:
P
N2
m²
%
90mm DOWNPIPEDP
NOTE:ALL PROPOSED STORMWATERTO BE DISCHARGED TO EXISTINGINFRASTRUCTURE
SITE COVERAGESITE AREA 1610.6
PROPOSED BUILDING FOOTPRINT 556.3PROPOSED SITE COVERAGE 34.54
m²EROSION AND SEDIMENT CONTROLMEASURES ARE TO BE IMPLEMENTEDON THE SITE IN ACCORDANCE WITHCOUNCIL REQUIREMENTS
PROPOSEDUNIT 1
DECK
PORCH
GARAGE PARKINGUNIT 1
PROPOSEDUNIT 2
DECK
PORCH
GARAGE PARKINGUNIT 2
PROPOSEDUNIT 3
DECK
PORCH
GARAGE PARKINGUNIT 3
PROPOSEDUNIT 4
DECK
PORCH
GARAGE
PARKINGUNIT 4
TURNING
VISITORPARKING
1500
1500
1500
1500
1500
4000
3400
625563555855
7600
5865
DRIVEWAY433.0m²DRIVEWAY
5500
5870
6015 6615
5835
5980 6580
5800
5945 6545
5765
5905
6510
PASSING BA
Y
PASSING BA
Y
PRIVATE OPEN SPACE
PRIVATE OPEN SPACE
GENERAL NOTES:
1. THIS PLAN HAS BEEN PREPARED BY SURVEY PLUS FROM ACOMBINATION OF EXISTING RECORDS AND FIELD SURVEY FOR THEPURPOSES OF SHOWING THE PHYSICAL FEATURES OF THE LANDAND SHOULD NOT BE USED FOR ANY OTHER PURPOSE.
2. TITLE BOUNDARIES SHOWN WERE NOT VERIFIED OR MARKED ATTHE TIME OF THIS SURVEY.
3. SERVICES SHOWN ON THIS PLAN WERE LOCATED WHEREPOSSIBLE BY FIELD SURVEY. THEY ARE NOT A COMPLETE PICTURE OFSERVICES ON SITE. ALL SERVICE LOCATIONS ARE TO BE VERIFIEDBEFORE COMMENCEMENT OF ANY WORK ON SITE, IN PARTICULARTHOSE SERVICES NOT PREVIOUSLY LOCATED THROUGH FIELDSURVEY.
4. SURVEY PLUS CAN NOT ACCEPT LIABILITY WHATSOEVER FORLOSS OR DAMAGE CAUSED TO ANY UNDERGROUND SERVICEWHETHER SHOWN BY OUR SURVEY OR NOT.
5. THIS NOTE IS AN INTEGRAL PART OF THIS PLAN/DATA.REPRODUCTION OF THIS PLAN OR ANY PART OF IT WITHOUT THISNOTE BEING INCLUDED IN FULL WILL RENDER THE INFORMATIONSHOWN ON SUCH A REPRODUCTION INVALID AND NOT SUITABLEFOR USE WITHOUT PRIOR AUTHORITY OF SURVEY PLUS.
6. HORIZONTAL DATUM IS MGA (Map Grid Australia).
7. VERTICAL DATUM IS AHD (Australian Height Datum).
8. CONTOUR INTERVAL IS 0.2 METRES, INDEX IS 1.0 METRES.
9. SURVEY BY ROBOTIC TOTAL STATION AND GPS.
1 . BOUNDARIES ARE COMPILED ONLY FROM S ANDRELEVANT SURVEY INFORMATION OBTAINED FROM LAND TITLESOFFICE AND ARE APPROXIMATE AND SUBJECT TO SURVEY.
11. ALL WINDOWS WERE NOT ABLE TO BE LOCATED DUE TOOBSTRUCTION OF LINE OF SIGHT FROM TOTAL STATION.WINDOW LOCATIONS ARE APPROXIMATE ONLY DUE TO BEINGUNABLE TO BE PERPENDICULAR TO WINDOWS WHEN LOCATINGWITH TOTAL STATION.
3D DATA TURNED OFF IN LAYER CONTROL.· 3D TIN· MAJOR CONTOUR 3D· MINOR CONTOUR 3D
IMPERVIOUS AREASITE AREA 1610.62
PROPOSED BUILDINGS FOOTPRINT 556.3
PROPOSED DRIVEWAYS 433.0
PROPOSED TOTAL IMPERVIOUS AREA 989.3
PROPOSED TOTAL IMPERVIOUS AREA 61.42
m²
%
m²
m²m²
WASTESTORAGE
WASTESTORAGE
WASTESTORAGE
WASTESTORAGE
LIGHTING INACCORDANCE
WITH AS &COUNCIL
REQUIREMENTS
LIGHTING INACCORDANCE
WITH AS &COUNCIL
REQUIREMENTS
SCREENSCREENSCREEN
MAILBOXES
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
DP
FFL RL. 42.60 FFL RL. 42.00 FFL RL. 41.60 FFL RL. 41.60
FFL RL. 42.55FFL RL. 41.95
FFL RL. 41.95FFL RL. 42.55
FFL RL. 41.55 FFL RL. 41.55
FFL RL. 41.55 FFL RL. 41.551.
8mH
TIMBE
R FE
NC
E
1.8mH TIMBER
FENCE
1.8m
H TIM
BER
FEN
CE
1.8m
H TIM
BER
FEN
CE
1.8m
H TIM
BER
FEN
CE
4500
LANDSCAPING
RID
GE
RL. 4
6.98
RID
GE
RL. 4
6.38
RID
GE
RL. 4
5.98
RID
GE
RL. 4
5.98
TIMBER FENCE TO BE WHOLLY LOCATEDBEHIND THE 4.5M FRONT OFFSET
PRIVATE OPEN SPACE
PRIVATE OPEN SPACE
UNIT 4 PRIVATEOPEN SPACE
164.7m²
UNIT 3 PRIVATEOPEN SPACE
93.3m²
UNIT 2 PRIVATEOPEN SPACE
96.5m²
UNIT 1 PRIVATEOPEN SPACE
139.3m²
UPUP
UP
CONCRETESLAB TO
ENGINEER'SDETAILS
4565
FENCE TO BDY
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:250
1I. Brown CC6652
01
![Page 4: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/4.jpg)
PROPOSED FLOOR PLANRESIDENCE: 139.1m²
CEILING MOUNTEDINTERCONNECTED SMOKEDETECTORS, MAINS WIRED WITHBATTERY BACKUP, ALL INACCORDANCE WITH AS 3786.
AREAS:
FLOOR AREA: 113.4 m²PORCH: 0.8 m²GARAGE: 24.8 m²
TOTAL AREA: 139.1 m²
MASONRY ARTICULATION JOINT -LOCATION TO ENGINEER'S DETAILS
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
90mm DOWNPIPEDP
UP
820
720
720
820
820
P
RH/C
T/UB
O
DW
REF
820
720
2 X
SLD
DRS
2 X
SLD
DRS
KITCHEN
LDY
LINEN
LOUNGE
DRESSING
BATHGARAGE
BEDROOM 3
BEDROOM 2
2 X SLD DRS
ROBE
ROBE
ENTRY
ENSUITE
DINING
DECK MASTERBEDROOM
S
820
CONCRETE S
LAB T
O
ENGIN
EER'S
DETAILS
820
22.5m²CH:2400
FF:Concrete
9.0m²CH:2400FF:Tiles
18.1m²CH:2400
FF:Carpet
11.9m²CH:2400 FF:Carpet
2.8m²CH:2400
FF:Carpet
14.2m²CH:2400
FF:Carpet
10.8m²CH:2400
FF:Carpet
13.8m²CH:2400
FF:Carpet
5.8m²CH:2400
FF:Carpet
6.6m²CH:2400 FF:Tiles
4.0m²CH:2400 FF:Tiles
11990
3000 8990250 4550 90 3850 250
250 7550 90 1860 90 1900 250
4100 1010 3180 3700
250 3000 90510250 1010 90 3000 90 3450 250
250 3600 90 1170 90
250 2800 90 1970 90
250 2800 9051090 4060
1010 90 1900 90
90 3850 250
160 61
011
860
1263
0
9630
3000
250
3400
9023
5090
3200
250
250
2300
9010
1090
910
9013
5090
6200
250
230
6000
9021
0090
3100
250
230
6600
9015
0090
9043
9090
51090
2270
90
9049
9090
7050
250
840
250
4240
DP
DP
DP
DP
DP
RoofAccess
AAW1818AAW1818
AA
W06
18A
AW
1006
AAW1818
OBS
C.
AAW1818
AAW1018
ASD
2121
AA
W06
12A
AW
1012
OBS
C.
BTH SHR
WC VB
SHR
VB WC
EXTENT OF STEPS TO BECONFIRMED ON SITE
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS - UNIT 1 & 2
TWM
AAW1818
FALL
FALL
FALL
FALL
CONCRETE SLAB TO ENGINEER'S DETAILS- UNIT 3 & 4
UNIT 1
P.CONC.
FFL RL. 41.55
FFL RL. 41.60
FFL RL. 41.55
FFL RL. 41.60
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
2I. Brown CC6652
02
![Page 5: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/5.jpg)
PROPOSED FLOOR PLANRESIDENCE: 139.1m²
CEILING MOUNTEDINTERCONNECTED SMOKEDETECTORS, MAINS WIRED WITHBATTERY BACKUP, ALL INACCORDANCE WITH AS 3786.
AREAS:
FLOOR AREA: 113.4 m²PORCH: 0.8 m²GARAGE: 24.8 m²
TOTAL AREA: 139.1 m²
MASONRY ARTICULATION JOINT -LOCATION TO ENGINEER'S DETAILS
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
90mm DOWNPIPEDP
UP
820
720
720
820
820
P
RH/C
T/UB
O
DW
REF
820
720
2 X
SLD
DRS
2 X
SLD
DRS
KITCHEN
LDY
LINEN
LOUNGE
DRESSING
BATHGARAGE
BEDROOM 3
BEDROOM 2
2 X SLD DRS
ROBE
ROBE
ENTRY
ENSUITE
DINING
DECK MASTERBEDROOM
S
820
CONCRETE S
LAB T
O
ENGIN
EER'S
DETAILS
820
22.5m²CH:2400
FF:Concrete
9.0m²CH:2400FF:Tiles
18.1m²CH:2400
FF:Carpet
11.9m²CH:2400 FF:Carpet
2.8m²CH:2400
FF:Carpet
14.2m²CH:2400
FF:Carpet
10.8m²CH:2400
FF:Carpet
13.8m²CH:2400
FF:Carpet
5.8m²CH:2400
FF:Carpet
6.6m²CH:2400 FF:Tiles
4.0m²CH:2400 FF:Tiles
11990
3000 8990250 4550 90 3850 250
250 7550 90 1860 90 1900 250
4100 1010 3180 3700
250 3000 90510250 1010 90 3000 90 3450 250
250 3600 90 1170 90
250 2800 90 1970 90
250 2800 9051090 4060
1010 90 1900 90
90 3850 250
160 61
011
860
1263
0
9630
3000
250
3400
9023
5090
3200
250
250
2300
9010
1090
910
9013
5090
6200
250
230
6000
9021
0090
3100
250
230
6600
9015
0090
9043
9090
51090
2270
90
9049
9090
7050
250
840
250
4240
DP
DP
DP
DP
DP
RoofAccess
AAW1818AAW1818
AA
W06
18A
AW
1006
AAW1818
OBS
C.
AAW1818
AAW1018
ASD
2121
AA
W06
12A
AW
1012
OBS
C.
BTH SHR
WC VB
SHR
VB WC
EXTENT OF STEPS TO BECONFIRMED ON SITE
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS - UNIT 1 & 2
TWM
AAW1818
FALL
FALL
FALL
FALL
CONCRETE SLAB TO ENGINEER'S DETAILS- UNIT 3 & 4
UNIT 2
P.CONC.
FFL RL. 41.55
FFL RL. 41.55
FFL RL. 41.60
FFL RL. 41.60
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
3I. Brown CC6652
03
![Page 6: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/6.jpg)
PROPOSED FLOOR PLANRESIDENCE: 139.1m²
CEILING MOUNTEDINTERCONNECTED SMOKEDETECTORS, MAINS WIRED WITHBATTERY BACKUP, ALL INACCORDANCE WITH AS 3786.
AREAS:
FLOOR AREA: 113.4 m²PORCH: 0.8 m²GARAGE: 24.8 m²
TOTAL AREA: 139.1 m²
MASONRY ARTICULATION JOINT -LOCATION TO ENGINEER'S DETAILS
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
90mm DOWNPIPEDP
UP
820
720
720
820
820
P
RH/C
T/UB
O
DW
REF
820
720
2 X
SLD
DRS
2 X
SLD
DRS
KITCHEN
LDY
LINEN
LOUNGE
DRESSING
BATHGARAGE
BEDROOM 3
BEDROOM 2
2 X SLD DRS
ROBE
ROBE
ENTRY
ENSUITE
DINING
DECK MASTERBEDROOM
S
820
CONCRETE S
LAB T
O
ENGIN
EER'S
DETAILS
820
22.5m²CH:2400
FF:Concrete
9.0m²CH:2400FF:Tiles
18.1m²CH:2400
FF:Carpet
11.9m²CH:2400 FF:Carpet
2.8m²CH:2400
FF:Carpet
14.2m²CH:2400
FF:Carpet
10.8m²CH:2400
FF:Carpet
13.8m²CH:2400
FF:Carpet
5.8m²CH:2400
FF:Carpet
6.6m²CH:2400 FF:Tiles
4.0m²CH:2400 FF:Tiles
11990
3000 8990250 4550 90 3850 250
250 7550 90 1860 90 1900 250
4100 1010 3180 3700
250 3000 90510250 1010 90 3000 90 3450 250
250 3600 90 1170 90
250 2800 90 1970 90
250 2800 9051090 4060
1010 90 1900 90
90 3850 250
160 61
011
860
1263
0
9630
3000
250
3400
9023
5090
3200
250
250
2300
9010
1090
910
9013
5090
6200
250
230
6000
9021
0090
3100
250
230
6600
9015
0090
9043
9090
51090
2270
90
9049
9090
7050
250
840
250
4240
DP
DP
DP
DP
DP
RoofAccess
AAW1818AAW1818
AA
W06
18A
AW
1006
AAW1818
OBS
C.
AAW1818
AAW1018
ASD
2121
AA
W06
12A
AW
1012
OBS
C.
BTH SHR
WC VB
SHR
VB WC
EXTENT OF STEPS TO BECONFIRMED ON SITE
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS - UNIT 1 & 2
TWM
AAW1818
FALL
FALL
FALL
FALL
CONCRETE SLAB TO ENGINEER'S DETAILS- UNIT 3 & 4
UNIT 3
P.CONC.
FFL RL. 42.00
FFL RL. 41.95
FFL RL. 41.95
FFL RL. 42.00
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
4I. Brown CC6652
04
![Page 7: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/7.jpg)
PROPOSED FLOOR PLANRESIDENCE: 139.1m²
CEILING MOUNTEDINTERCONNECTED SMOKEDETECTORS, MAINS WIRED WITHBATTERY BACKUP, ALL INACCORDANCE WITH AS 3786.
AREAS:
FLOOR AREA: 113.4 m²PORCH: 0.8 m²GARAGE: 24.8 m²
TOTAL AREA: 139.1 m²
MASONRY ARTICULATION JOINT -LOCATION TO ENGINEER'S DETAILS
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
90mm DOWNPIPEDP
UP
820
720
720
820
820
P
RH/C
T/UB
O
DW
REF
820
720
2 X
SLD
DRS
2 X
SLD
DRS
KITCHEN
LDY
LINEN
LOUNGE
DRESSING
BATHGARAGE
BEDROOM 3
BEDROOM 2
2 X SLD DRS
ROBE
ROBE
P.
ENTRY
ENSUITE
DINING
DECK MASTERBEDROOM
S
820
CONCRETE S
LAB T
O
ENGIN
EER'S
DETAILS
820
22.5m²CH:2400
FF:Concrete
9.0m²CH:2400FF:Tiles
18.1m²CH:2400
FF:Carpet
11.9m²CH:2400 FF:Carpet
2.8m²CH:2400
FF:Carpet
14.2m²CH:2400
FF:Carpet
10.8m²CH:2400
FF:Carpet
13.8m²CH:2400
FF:Carpet
5.8m²CH:2400
FF:Carpet
6.6m²CH:2400 FF:Tiles
4.0m²CH:2400 FF:Tiles
11990
3000 8990250 4550 90 3850 250
250 7550 90 1860 90 1900 250
4100 1010 3180 3700
250 3000 90510250 1010 90 3000 90 3450 250
250 3600 90 1170 90
250 2800 90 1970 90
250 2800 9051090 4060
1010 90 1900 90
90 3850 250
160 61
011
860
1263
0
9630
3000
250
3400
9023
5090
3200
250
250
2300
9010
1090
910
9013
5090
6200
250
230
6000
9021
0090
3100
250
230
6600
9015
0090
9043
9090
51090
2270
90
9049
9090
7050
250
840
250
4240
DP
DP
DP
DP
DP
RoofAccess
AAW1818AAW1818
AA
W06
18A
AW
1006
AAW1818
OBS
C.
AAW1818
AAW1018
ASD
2121
AA
W06
12A
AW
1012
OBS
C.
BTH SHR
WC VB
SHR
VB WC
EXTENT OF STEPS TO BECONFIRMED ON SITE
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS - UNIT 1 & 2
CONC.
TWM
AAW1818
FALL
FALL
FALL
FALL
CONCRETE SLAB TO ENGINEER'S DETAILS- UNIT 3 & 4
UNIT 4
FFL RL. 42.60
FFL RL. 42.55
FFL RL. 42.60
FFL RL. 42.55
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
5I. Brown CC6652
05
![Page 8: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/8.jpg)
EASTERN ELEVATION
2400
2400
SOUTHERN ELEVATION
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).UNIT 1
450
FFL RL. 41.60
CL RL. 44.00
FFL RL. 41.60
CL RL. 44.00
610 450
450
610
450 450
SELECTED LIGHTWEIGHT CLADDINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
SELECTED LIGHTWEIGHT CLADDINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
SELECTED ENTRY DOOR
(SLOPE RELATIONSHIP)
RISER AND GOING DIMENSIONS
= 250 mm
SLIP RESISTANCE OF STAIR TREADS TOCOMPLY WITH NCC 3.9.1.4 AND AS 4586.NOTE: BALUSTRADE MUST BE CAPABLE OFBEARING LOADING FORCESACCORDING TO AS1170.1
= 190mm
= 630 mm
ALUMINIUM FRAMED WINDOWS
SELECTED GARAGE DOOR
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
ALUMINIUM FRAMED WINDOWS
OBSCURED SAFETY GLASS
CONCRETE SLAB TO ENGINEER'S DETAILS
SELECTED ENTRY DOOR
ROOF PITCH 22.5°
ROOF PITCH 22.5° ROOF PITCH 22.5°
ROOF PITCH 22.5°
BOUN
DA
RY
BUILDING ENVELOPE45°
3000
4.5m
FRO
NT
OFF
SET
4835
MA
X HE
IGHT
FRO
M N
GL
4835
SCRE
EN H
EIG
HT A
BOV
E FF
L
RIDGE RL. 45.98
RIDGE RL. 45.98
CONCRETE SLAB TO ENGINEER'S DETAILS
1800H TIMBER FENCE
SELECTED TIMBER SLAT SCREEN (OR EQUIV.)INSTALLED IN ACCORDANCE WITH COUNCILREQUIREMENTS WITH MINIMUM 25% TRANSPARENCY
SCREEN ELEVATION
1700
SCRE
EN H
EIG
HT A
BOV
E FF
L
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
10I. Brown CC6652
10
![Page 9: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/9.jpg)
NORTHERN ELEVATION
2400
2400
WESTERN ELEVATION
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
FFL RL. 41.60
CL RL. 44.00
FFL RL. 41.60
CL RL. 44.00
450 450 450
450 450 450
(SLOPE RELATIONSHIP)
RISER AND GOING DIMENSIONS
= 250 mm
SLIP RESISTANCE OF STAIR TREADS TOCOMPLY WITH NCC 3.9.1.4 AND AS 4586.NOTE: BALUSTRADE MUST BE CAPABLE OFBEARING LOADING FORCESACCORDING TO AS1170.1
= 190mm
= 630 mm
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS
ALUMINIUM FRAMED WINDOWS
ALUMINIUM FRAMED WINDOWS
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
OBSCURED SAFETY GLASS
SELECTED FACE BRICK
ALUMINIUM FRAMED SLIDING DOOR
ROOF PITCH 22.5°
ROOF PITCH 22.5°
ROOF PITCH 22.5°
ROOF PITCH 22.5°
BOUN
DA
RY
BUILD
ING ENVEL
OPE
45°
3000
4835
MA
X HE
IGHT
FRO
M N
GL
4835
MA
X HE
IGHT
FRO
M N
GL
BUILDING ENVELOPE
EXTENT OF EXCAVATIONBATTER MAX 1:1.5
RIDGE RL. 45.98
RIDGE RL. 45.98
UNIT 1
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
11I. Brown CC6652
11
![Page 10: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/10.jpg)
2400
2400
SOUTHERN ELEVATION
EASTERN ELEVATION
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
450 610 450
450
610
450 450
SELECTED LIGHTWEIGHT CLADDINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
SELECTED LIGHTWEIGHT CLADDINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
SELECTED ENTRY DOOR
(SLOPE RELATIONSHIP)
RISER AND GOING DIMENSIONS
= 250 mm
SLIP RESISTANCE OF STAIR TREADS TOCOMPLY WITH NCC 3.9.1.4 AND AS 4586.NOTE: BALUSTRADE MUST BE CAPABLE OFBEARING LOADING FORCESACCORDING TO AS1170.1
= 190mm
= 630 mm
ALUMINIUM FRAMED WINDOWS
SELECTED GARAGE DOOR
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
ALUMINIUM FRAMED WINDOWS
OBSCURED SAFETY GLASS
CONCRETE SLAB TO ENGINEER'S DETAILS
SELECTED ENTRY DOOR
ROOF PITCH 22.5°
ROOF PITCH 22.5° ROOF PITCH 22.5°
ROOF PITCH 22.5°
BOUN
DA
RY
BUILDING ENVELOPE
45°
3000
4885
MA
X HE
IGHT
FRO
M N
GL
4885
MA
X HE
IGHT
FRO
M N
GL
UNIT 2
FFL RL. 41.60
CL RL. 44.00
RIDGE RL. 45.98
FFL RL. 41.60
CL RL. 44.00
RIDGE RL. 45.98
BUILDING ENVELOPE
CONCRETE SLAB TO ENGINEER'S DETAILS
1800H TIMBER FENCE
SELECTED TIMBER SLAT SCREEN (OR EQUIV.)INSTALLED IN ACCORDANCE WITH COUNCILREQUIREMENTS WITH MINIMUM 25% TRANSPARENCY
SCREEN ELEVATION
1700
SCRE
EN H
EIG
HT A
BOV
E FF
L
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
12I. Brown CC6652
12
![Page 11: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/11.jpg)
NORTHERN ELEVATION
2400
2400
WESTERN ELEVATION
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
450 450 450
450 450 450
(SLOPE RELATIONSHIP)
RISER AND GOING DIMENSIONS
= 250 mm
SLIP RESISTANCE OF STAIR TREADS TOCOMPLY WITH NCC 3.9.1.4 AND AS 4586.NOTE: BALUSTRADE MUST BE CAPABLE OFBEARING LOADING FORCESACCORDING TO AS1170.1
= 190mm
= 630 mm
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS
ALUMINIUM FRAMED WINDOWS
ALUMINIUM FRAMED WINDOWS
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
OBSCURED SAFETY GLASS
SELECTED FACE BRICK
ALUMINIUM FRAMED SLIDING DOOR
ROOF PITCH 22.5°
ROOF PITCH 22.5°
ROOF PITCH 22.5°
ROOF PITCH 22.5°
BOUN
DA
RY
BUILD
ING EN
VELOPE
45°
3000
4885
MA
X HE
IGHT
FRO
M N
GL
4885
MA
X HE
IGHT
FRO
M N
GL
BUILDING ENVELOPE
EXTENT OF EXCAVATIONBATTER MAX 1:1.5
UNIT 2
FFL RL. 41.60
CL RL. 44.00
RIDGE RL. 45.98
FFL RL. 41.60
CL RL. 44.00
RIDGE RL. 45.98
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
13I. Brown CC6652
13
![Page 12: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/12.jpg)
2400
2400
SOUTHERN ELEVATION
EASTERN ELEVATION
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
450 610 450
450
610
450 450
SELECTED LIGHTWEIGHT CLADDINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
SELECTED LIGHTWEIGHT CLADDINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
SELECTED ENTRY DOOR
(SLOPE RELATIONSHIP)
RISER AND GOING DIMENSIONS
= 250 mm
SLIP RESISTANCE OF STAIR TREADS TOCOMPLY WITH NCC 3.9.1.4 AND AS 4586.NOTE: BALUSTRADE MUST BE CAPABLE OFBEARING LOADING FORCESACCORDING TO AS1170.1
= 190mm
= 630 mm
ALUMINIUM FRAMED WINDOWS
SELECTED GARAGE DOOR
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
ALUMINIUM FRAMED WINDOWS
OBSCURED SAFETY GLASS
CONCRETE SLAB TO ENGINEER'S DETAILS
SELECTED ENTRY DOOR
ROOF PITCH 22.5°
ROOF PITCH 22.5° ROOF PITCH 22.5°
ROOF PITCH 22.5°
BOUN
DA
RY
BUILDING ENVELOPE45°
3000
4820
MA
X HE
IGHT
FRO
M N
GL
4820
MA
X HE
IGHT
FRO
M N
GL
UNIT 3
RIDGE RL. 46.38
FFL RL. 42.00
CL RL. 44.40
RIDGE RL. 46.38
FFL RL. 42.00
CL RL. 44.40
BUILDING ENVELOPE
CONCRETE SLAB TO ENGINEER'S DETAILS
1800H TIMBER FENCE
SELECTED TIMBER SLAT SCREEN (OR EQUIV.)INSTALLED IN ACCORDANCE WITH COUNCILREQUIREMENTS WITH MINIMUM 25% TRANSPARENCY
SCREEN ELEVATION
1700
SCRE
EN H
EIG
HT A
BOV
E FF
L
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
14I. Brown CC6652
14
![Page 13: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/13.jpg)
NORTHERN ELEVATION
2400
2400
WESTERN ELEVATION
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
450 450 450
450 450 450
(SLOPE RELATIONSHIP)
RISER AND GOING DIMENSIONS
= 250 mm
SLIP RESISTANCE OF STAIR TREADS TOCOMPLY WITH NCC 3.9.1.4 AND AS 4586.NOTE: BALUSTRADE MUST BE CAPABLE OFBEARING LOADING FORCESACCORDING TO AS1170.1
= 190mm
= 630 mm
SELECTED CONCRETE SLAB TO ENGINEER'SDETAILS
ALUMINIUM FRAMED WINDOWS
ALUMINIUM FRAMED WINDOWS
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
OBSCURED SAFETY GLASS
SELECTED FACE BRICK
ALUMINIUM FRAMED SLIDING DOOR
ROOF PITCH 22.5°
ROOF PITCH 22.5°
ROOF PITCH 22.5°
ROOF PITCH 22.5°
BOUN
DA
RY
BUILD
ING ENVEL
OPE
45°
3000
4820
MA
X HE
IGHT
FRO
M N
GL
4820
MA
X HE
IGHT
FRO
M N
GL
BUILDING ENVELOPE
EXTENT OF EXCAVATIONBATTER MAX 1:1.5
UNIT 3
RIDGE RL. 46.38
FFL RL. 42.00
CL RL. 44.40
RIDGE RL. 46.38
FFL RL. 42.00
CL RL. 44.40
SELECTED CONCRETE SLAB TO ENGINEER'SDETAILS
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
15I. Brown CC6652
15
![Page 14: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/14.jpg)
2400
2400
SOUTHERN ELEVATION
EASTERN ELEVATION
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
450 610 450
450
610
450 450
SELECTED LIGHTWEIGHT CLADDINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
SELECTED LIGHTWEIGHT CLADDINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
SELECTED ENTRY DOOR
(SLOPE RELATIONSHIP)
RISER AND GOING DIMENSIONS
= 250 mm
SLIP RESISTANCE OF STAIR TREADS TOCOMPLY WITH NCC 3.9.1.4 AND AS 4586.NOTE: BALUSTRADE MUST BE CAPABLE OFBEARING LOADING FORCESACCORDING TO AS1170.1
= 190mm
= 630 mm
ALUMINIUM FRAMED WINDOWS
SELECTED GARAGE DOOR
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
ALUMINIUM FRAMED WINDOWS
OBSCURED SAFETY GLASS
CONCRETE SLAB TO ENGINEER'S DETAILS
SELECTED ENTRY DOOR
ROOF PITCH 22.5°
ROOF PITCH 22.5° ROOF PITCH 22.5°
ROOF PITCH 22.5°
BOUN
DA
RY
BUILDING ENVELOPE
45°
3000
4680
MA
X HE
IGHT
FRO
M N
GL
4680
MA
X HE
IGHT
FRO
M N
GL
UNIT 4
CONCRETE SLAB TO ENGINEER'S DETAILS
1800H TIMBER FENCE
BUILDING ENVELOPE
FFL RL. 42.60
CL RL. 45.00
RIDGE RL. 46.98
FFL RL. 42.60
CL RL. 45.00
RIDGE RL. 46.98
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
16I. Brown CC6652
16
![Page 15: DEVELOPMENT APPLICATION · 2020. 8. 13. · DEVELOPMENT APPLICATION PDPLANPMTD-2020/009857 APPLICANT: Creative Homes Hobart PROPOSAL: 4 Multiple Dwellings LOCATION: 5 Jardinelle Road,](https://reader034.vdocument.in/reader034/viewer/2022052010/601ff55feeebb929e60f62f4/html5/thumbnails/15.jpg)
NORTHERN ELEVATION
2400
2400
WESTERN ELEVATION
Framing part 3.4 NCCAll timber framing, fixing and bracing shallcomply with AS 1684 and the requirementsof NCC part 3.4.3 manufactured sizes mustnot be undersized to those specified, for alltimber sizes, stress grades, spacing and wallbracing refer to Engineer's details. Tie-downdetails shall comply with the requirements oftables 3.4.3.8 and 3.4.3.9. Structural steelmembers shall comply with the requirementsof clauses in part 3.4.4. Refer to Engineer'sdetails where provided.
Glazing part 3.6 NCC All windows to bealuminium awning style, double glazed(obscured safety glass to bathrooms asshown on drawings) all glazing shall complywith the requirements of AS 2047-AS 1288and NCC clauses in part 3.6.
Human impact safety requirements shallcomply with NCC clauses 3.6.4 pane within500mm from finished floor level & glazed fullheight
Note:Builder and subcontractors to verify alldimension and levels prior to thecommencement of any work. Give 24hrsminimum notice where amendments arerequired to design of working drawings.These drawings are to be read inconjunction with Engineer's and Surveyor'sdrawings and notes. Do not scale drawings.Dimensions are to take preference overscale. Building specification and Engineer'sdrawings shall override architecturaldrawings. All construction work shall becarried out in accordance with the statebuilding regulations, local council by-lawsand relevant NCC and AS codes.
Important notice for attention of Owners:the Owners attention is drawn to the factthat foundations and associated drainagein all sites requires continuing maintenanceto assist footing performance. Advice forfoundation maintenance is contained in theCSIRO building technology file 18 and it isthe Owners responsibility to maintain the sitein accordance with this document. Energyefficiency bulk insulation between externalstuds to be insulated with min R2.0. (Ensurebatts fit within cavity without compression,making sure that there is at least 25mm gapfrom the reflective surface).
External walls are to be clad with perforatedreflective foil over the outside of the timberframe. Ceiling to be insulated with R4.0 andreflective foil. Floor to be insulated with R2.0batts. Seal exhaust fans to Ensuite,Bathroom, Laundry and Kitchen. Building tobe sealed in accordance with NCC part3.12.3Construction of the external walls, floor androof compliance of air leakage to complywith NCC part 3.12.3.5
General:All flashings to be in accordance with part3.3 of the NCC. Weep holes and dampproof coursing in accordance with 3.3.4.4and 3.3.4.5 of the NCC. Fibre cement sheetin accordance with 3.5.3.4 of the NCC.Block construction in accordance with NCCrequirements. Plasterboard to internal walllinings and ceilings with selected cornice.(see below for wet areas)
Health & amenity part 3.8 NCC: showers,baths and wall fixtures to all wet areas shallcomply with the requirements of clauses,3.8.1.1, 3.8.1.2, 3.8.1.3, 3.8.1.4, 3.8.1.5 and3.8.1.6. In all wet areas provide selectedceramic tiles to concrete floors or over15mm cement sheeting where timberframed floors are proposed.
Provide waterproof plasterboard sheeting toall walls and ceilings. Provide ceramic tiles,lamipanel or other approved water resistantlining to a minimum height of 1800mm toshower walls and to a height of min 150mmbehind baths, basins, sinks, troughs, washingmachines and wall fixtures, for the requiredextent of area to be protected refer tofigures 3.8.1.1, 3.8.1.2 and 3.8.1.1.
For typical installation requirements ofshower recesses, tap flanges, showertroughs, floors & waterproof membranesrefer to figures 3.8.1.5, 3.8.1.6, 3.8.1.7, 3.8.1.8and 3.8.1.9. For typical installationrequirements & sealing of wall junctions withbenchtops, laundry sinks & baths refer tofigures 3.8.1.10 and 3.8.1.11. Materials shallcomply with the requirements of clauses3.8.1.3, 3.8.1.4 and 3.8.1.5. Refer to AS3740-2010 for waterproofing of domesticwet areas, as well as appropriate wall &floor treatment when not using aprefabricated shower unit (eg. Min 1:100 fallto waste).
450 450 450
450 450 450
(SLOPE RELATIONSHIP)
RISER AND GOING DIMENSIONS
= 250 mm
SLIP RESISTANCE OF STAIR TREADS TOCOMPLY WITH NCC 3.9.1.4 AND AS 4586.NOTE: BALUSTRADE MUST BE CAPABLE OFBEARING LOADING FORCESACCORDING TO AS1170.1
= 190mm
= 630 mm
SELECTED CONCRETE SLAB TO ENGINEER'SDETAILS
SELECTED TIMBER DECK WITH STAIR TOENGINEER'S DETAILS AND INSTALLED INACCORDANCE WITH NCC & AS
ALUMINIUM FRAMED WINDOWS
ALUMINIUM FRAMED WINDOWS
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
SELECTED COLORBOND ROOFINGINSTALLED TO MANUFACTURER'SSPECIFICATIONS
COLORBOND FASCIA AND GUTTERING
OBSCURED SAFETY GLASS
SELECTED FACE BRICK
ALUMINIUM FRAMED SLIDING DOOR
ROOF PITCH 22.5°
ROOF PITCH 22.5°
ROOF PITCH 22.5°
ROOF PITCH 22.5°
BOUN
DA
RY
BUILD
ING ENVEL
OPE
45°
3000
4680
MA
X HE
IGHT
FRO
M N
GL
4680
MA
X HE
IGHT
FRO
M N
GL
BUILDING ENVELOPE
EXTENT OF EXCAVATIONBATTER MAX 1:1.5
UNIT 4
FFL RL. 42.60
CL RL. 45.00
RIDGE RL. 46.98
FFL RL. 42.60
CL RL. 45.00
RIDGE RL. 46.98
D
ABCD
IBIBIBIB
5/6/209/6/2022/7/2011/8/20
ISSUED FOR APPROVALWINDOW CHANGESCOUNCIL RFI, WINDOW CHANGESCOUNCIL RFI, PLAN OF EACH UNIT
5 Jardinelle RoadRokeby
Le Minh Trang Phan
MAY 2020
116621Custom
of 19
DRAWING NO:
DESIGN TYPE:
CLIENT:JOB ADDRESS:
DRAWN:
SHEET:
SCALE: REV:
©
ALWAYS USE WRITTEN DIMENSIONS.DO NOT SCALE DRAWINGS.
ANY WORK OR MAKING ANY SHOP DRAWINGS.AND LEVELS AT THE JOB PRIOR TO COMMENCINGCONTRACTOR MUST VERIFY ALL DIMENSIONS DATE:INITIAL:DESCRIPTION:REV:PROJECT NORTH
CHECKED: DATE:
DATE:
ACCRED. NO.:DESIGNER:
CREATIVE HOMES HOBART, CNR OF ELWICK ROAD & BROOKER HIGHWAY, GLENORCHY 7010 PH: 03 6272 3000
Creative HomesHOBART
COPYRIGHT IN WHOLE OR IN PART
I. Brown
1:100
17I. Brown CC6652
17