development application · 2021. 4. 22. · development application pdplanpmtd-2021/017523...
TRANSCRIPT
DEVELOPMENT APPLICATION
PDPLANPMTD-2021/017523
APPLICANT: Hotondo Homes
PROPOSAL: Dwelling
LOCATION: 1 Venerable Drive, Rokeby
RELEVANT PLANNING SCHEME: Clarence Interim Planning Scheme 2015
ADVERTISING EXPIRY DATE: 10 May 2021
In addition to the Application Form(s), Certificate of Title(s) and any associated
consent documents the following information is available on request:
• Nil
The relevant plans and documents can be inspected at the Council offices, 38 Bligh
Street, Rosny Park, during normal office hours until 10 May 2021. In addition to
legislative requirements, plans and documents can also be viewed at
www.ccc.tas.gov.au during these times.
Any person may make representations about the application to the General Manager,
by writing to PO Box 96, Rosny Park, 7018 or by electronic mail to
[email protected]. Representations must be received by Council on or before
10 May 2021.
To enable Council to contact you if necessary, would you please also include a day
time contact number in any correspondence you may forward.
Any personal information submitted is covered by Council’s privacy policy, available
at www.ccc.tas.gov.au or at the Council offices.
BUILDING DRAWINGS
No DRAWING
01 SITE PLAN
02 SITE DRAINAGE PLAN
03 FLOOR PLAN
04 DOOR AND WINDOW SCHEDULES
05 ELEVATIONS
06 ELEVATIONS
07 ROOF PLAN
08 ELECTRICAL/REFLECTED CEILING PLAN
09 GROUND FLOOR PLUMBING PLAN
10 PERSPECTIVES
GENERAL PROJECT INFORMATIONTITLE REFERENCE: 25/178880
SITE AREA: 907 m2DESIGN WIND SPEED: N3SOIL CLASSIFICATION: P
CLIMATE ZONE: 7ALPINE AREA: NO
CORROSIVE ENVIRONMENT: NOBAL RATING: EXEMPT
OTHER KNOWN HAZARDS: NONE KNOWN
p(h)+
Accredited Building Practitioner: Frank Geskus -No CC246A
160 New Town Road, New Town, Hobart 7008
info@ primedesigntas.com.au primedesigntas.com.au 03 6228 4575
p(l) + 10 Goodman Court , Invermay Launceston 7248
03 6332 3790
APRIL 2021
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
PLANNING
J. COAD & S. DOBBYPDH20010
SELECTED HOTONDO PLAN: CASCADE 121 (MODIFIED)SELECTED HOTONDO FACADE: THEO
H229
GARAGE AREA 23.28 m2 ( 2.50 SQUARES )
LIVING AREA 118.42 m2 ( 12.73 SQUARES )
PORCH 1.46 m2 ( 0.16 SQUARES )
TOTAL AREA 143.16 15.39 SQUARES )m2 (
25
26
PEDESTRIAN PATH
BACK OF KERB
EDGE OF BITUMEN
TO
P O
F B
ANK
TO
P O
F B
ANK
CROSSOVER
PROPOSED DRIVEWAY51 m2
PROPOSED RESIDENCEFFL. 25.300
PIP
ELIN
E S
ER
VIC
ES E
ASEM
ENT
MO
CKR
IDG
E R
OAD
VENERABLE DRIVE
PATH 1.0m WIDE
EX. TREE
STORMWATER CONN.
SEWER LOT CONN.RL. 24.71
SEWER MAIN
STORMWATER MAIN
BOUNDARY 5.99 m
BO
UND
AR
Y 2
7.9
7 m
BOUNDARY 21.62 m
BO
UND
AR
Y 4
0.2
9 m
BOUNDARY 16.75 m
BO
UND
AR
Y 9
.31 m
ELEC. TURRET
COMM. LOT CONN.
ELEC. LOT CONN.
WATER METER
STORMWATER MANHOLERL. 23.62
DATUMSEWER MANHOLERL. 23.67
STORMWATER MANHOLERL. 23.56
SEWER MANHOLE
RL. 25.52
STORMWATER MANHOLE
RL. 25.18
3600
52632273
9000
6903
5255
1529
1500
LOCATION OF SLAB FORPROPOSED FUTURE SHED
6m x 9m(NOTE SHED IS NOT PART OF THIS
APPLICATION)
9524
STORMWATER MAIN
SEWER MAIN
17862
P2
P1
PRIVATE OPEN SPACE24m2 IS SHOWN TO THE NORTH AND LOCATED OFF THE MAIN LIVING ROOM.WITH A MINIMUM DIMENSION OF 4mGRADIENT NO STEEPER THAN 1:10
FALL
1:20
PIT
TOP OF BATTER
TOP OF BATTER
TO
P O
F B
ATTER
TO
P O
F B
ATTER
TO
P O
F B
ATTER
TOE OF BATTER
TOE OF BATTER
TO
E O
F B
ATTER
TO
E O
F B
ATTER
TOE OF BATTER
TOE OF BATTER
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
1 : 200
A.C.M.T.L.H.
SITE PLAN
PDH20010 -01
20.04.2021
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
PLANNING
J. COAD & S. DOBBY
04
LOT No. LOT AREA 50% 25%
850 425 212
NOTE: DIMENSIONED BOUNDARY OFFSETS TO THE PROPOSED BUILDING ARE TO THE EXTERNAL CLADDING U.N.O.
1 : 200
SITE PLAN
GENERAL NOTES• CHECK & VERIFY ALL DIMENSIONS & LEVELS ON SITE• WRITTEN DIMENSIONS TO TAKE PREFERENCE OVER
SCALED• ALL WORK TO BE STRICTLY IN ACCORDANCE WITH NCC
2019, ALL S.A.A.. CODES & LOCAL AUTHORITY BY-LAWS• ALL DIMENSIONS INDICATED ARE FRAME TO FRAME AND
DO NOT ALLOW FOR WALL LININGS• CONFIRM ALL FLOOR AREAS• ALL PLUMBING WORKS TO BE STRICTLY IN
ACCORDANCE WITH A.S. 3500 & APPROVED BY COUNCIL INSPECTOR
• BUILDER/PLUMBER TO ENSURE ADEQUATE FALL TO SITE CONNECTION POINTS IN ACCORDANCE WITH A.S. 3500 FOR STORMWATER AND SEWER BEFORE CONSTRUCTION COMMENCES
• THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE ENGINEER'S STRUCTURAL DRAWINGS
• ALL WINDOWS AND GLAZING TO COMPLY WITH A.S. 1288 & A.S. 2047
• ALL SET OUT OF BUILDINGS & STRUCTURES TO BE CARRIED OUT BY A REGISTERED LAND SURVEYOR AND CHECKED PRIOR TO CONSTRUCTION
• IF CONSTRUCTION OF THE DESIGN IN THIS SET OF DRAWINGS DIFFER FROM THE DESIGN AND DETAIL IN THESE AND ANY ASSOCIATED DOCUMENTS BUILDER AND OWNER ARE TO NOTIFY DESIGNER
• BUILDER'S RESPONSIBILITY TO COMPLY WITH ALL PLANNING CONDITIONS
• BUILDER TO HAVE STAMPED BUILDING APPROVAL DRAWINGS AND PERMITS PRIOR TO COMMENCEMENT OF CONSTRUCTION
• CONSTRUCTION TO COMPLY WITH AS 3959, READ IN CONJUNCTION WITH BUSHFIRE ATTACK LEVEL (BAL) ASSESSMENT REPORT.
SITE DETAIL
HORIZONTAL DATUM IS ARBITRARY
VERTICAL DATUM IS ARBITRARY
WARNINGS: THE DETAIL SHOWN / RECORDED • MAY ONLY BE CORRECT AT THE DATE OF SURVEY. • IS NOT A COMPLETE REPRESENTATION OF ALL
SURFACE AND UNDERGROUND DETAIL. • SHOULD ONLY BE USED FOR THE PURPOSES
INTENDED.
THE LOCATIONS OF UNDERGROUND SERVICES ARE APPROXIMATE ONLY AS INDICATED BY SURFACE FEATURES.
PRIOR TO ANY CONSTRUCTION REFER TO RELEVANT AUTHORITIESFOR DETAILED LOCATION OF ALL SERVICES.
CONTOUR INTERVAL 0.2m
SEWER AND WATER SERVICES• ALL WORKS IN
ACCORDANCE WITH WATER SUPPLY CODE OF AUSTRALIA AND TASWATER SUPPLEMENTS
• WORKS TO BE DONE BY TASWATER AT DEVELOPERS COST
DRIVEWAY GRADIENTMAXIMUM GRADIENT 1:4 (25%)TO AS 2890
CAR PARKING GRADIENTPARALLEL TO PARKING ANGLE 1:20 (5%)CROSSFALL 1:16 (6.25%)
25
26
BO
UND
AR
Y 4
0.2
9 m
BO
UND
AR
Y 2
7.9
7 m
BOUNDARY 21.62 m
BOUNDARY 16.75 mBOUNDARY 5.99 m
P2
P1
PEDESTRIAN PATH
BACK OF KERB
EDGE OF BITUMEN
TO
P O
F B
ANK
TO
P O
F B
ANK
CROSSOVER
PROPOSED DRIVEWAY51 m2
PATH 1.0m WIDE
EX. TREE
STORMWATER CONN.
SEWER LOT CONN.RL. 24.71
SEWER MAIN
STORMWATER MAIN
ELEC. TURRET
COMM. LOT CONN.
ELEC. LOT CONN.
WATER METER
STORMWATER MANHOLERL. 23.62STORMWATER MANHOLE
RL. 23.56
SEWER MANHOLE
RL. 25.52
STORMWATER MANHOLE
RL. 25.18
LOCATION OF SLAB FORPROPOSED FUTURE SHED
6m x 9m
STORMWATER MAIN
SEWER MAIN
FALL
BO
UND
AR
Y 9
.31 m
PIP
ELIN
E S
ER
VIC
ES E
ASEM
ENT
TOP OF BATTER
TOP OF
BATTER
TO
P O
F B
ATTER
TO
P O
F B
ATTER
TO
P O
F B
ATTER
TOE OF BATTER
TOE OF BATTER
TO
E O
F B
ATTER
TO
E O
F B
ATTER
TOE OF BATTER
TOE OF BATTER
D.P.I.O.
I.O.
I.O.
ORG
D.P.
H.P.
D.P.
D.P.
D.P.
PIT
S.B.
HWC
D.P.
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
1 : 200
A.C.M.B.K.S.
SITE DRAINAGE PLAN
PDH20010 -02
20.04.2021
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
PLANNING
J. COAD & S. DOBBY
041 : 200
SITE DRAINAGE PLAN
PITS: ALL GRATED PITS SIZED AND INSTALLED PER AS/NZS 3500.2018 PART 3
ORGS: OVERFLOW RELIEF GULLYS TO BE BRANCHED SEPERATE AND NOT PASS THROUGH. REFER AS/NZS 3500.2018 PART 2
S/W: STORMWATER PIPES TO BE SIZED PER ASNZS 3500.2018 PART 3
VENTS: DRAINAGE VENTS TO BE LOCATED BEFORE LAST FITTING AT THE END OF THE LINE PER AS/NZS 3500.2018 PART 2
240v SMOKE ALARM
EXHAUST FAN-VENT TO OUTSIDE AIR.
SLIDING DOOR
FLOOR WASTE
LEGEND
S/D
COLUMNCOL
GLASS SCREENG.S.
HOT WATER CYLINDERHWC
FW
TOWEL RAILT.R.
SKYLIGHTS/L
DISHWASHERDW
MICROWAVE SPACEMW
36001200
450 900 4080
3290
6970
3250
360
050
0
3200
620
0
W/CSHR
SHELVES
VAN.
VAN.
SHRB
ATH
W/M
S/D
TV
TV
W/C
B'BAR
O/H
T.R.
T.R
.
G.S
.
G.S
.
MWDW
HWC
312
016
60
180
0290
0290
0
510
12040 O/A
8750
8750 3290
8270
2740 4890
16001600
FR
H/P
P
1885
6680
5755
350
02440
7720
1450
90
0
HALL
5730
14320
O/A
711
0
120
090
0
BED 1BED 2
BED 3
ENS.WIR
BATH
GARAGE
L'DRY
LIVINGDINING
KITCHEN
HALL
W4
W1W2W3
1
2
W5
W8
W7
W6
W10
W0
9
7 8
3
4
5
6
2.6W X 2.1H PANELLIFT DOOR
ROBE ROBE
LINEN
COL.
0.92 m²
PORCH
SINK
TR
750
900x 900
900x 1200
900
1011
S/L
9
H.P.
H.P.S/L
S.B
.
12
1696 1814
100
015
017
35
100
0360
140
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
1 : 100
A.C.M.T.L.H.
FLOOR PLAN
PDH20010 -03
20.04.2021
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
PLANNING
J. COAD & S. DOBBY
04
NOTE:FLOOR AREAS INCLUDE TO EXTERNAL FACE OF BUILDING AND GARAGE, UNLESS OTHERWISE STATED. DECKS AND OUTDOOR AREAS ARE CALCULATED SEPARATELY.
GARAGE AREA 23.28 m2 ( 2.50 SQUARES )
LIVING AREA 118.42 m2 ( 12.73 SQUARES )
PORCH 1.46 m2 ( 0.16 SQUARES )
TOTAL AREA 143.16 15.391 : 100
FLOOR PLAN
SQUARES )m2 (
ALUMINIUM WINDOWS DOUBLE GLAZING COMPLETE WITH FLY SCREENS TO SUIT EXEMPT BAL RATING.ALL WINDOW MEASUREMENTS TO BE VERIFIED ON SITEPRIOR TO ORDERING
DOOR SCHEDULE
MARK WIDTH TYPE REMARKS
1 820 EXTERNAL ENTRY DOOR
2 820 INTERNAL TIMBER DOOR
3 820 INTERNAL TIMBER DOOR
4 720 INTERNAL TIMBER DOOR
5 820 INTERNAL TIMBER DOOR
6 720 INTERNAL TIMBER DOOR
7 720 INTERNAL TIMBER DOOR
8 720 INTERNAL TIMBER DOOR
9 820 INTERNAL TIMBER DOOR
10 820 INTERNAL TIMBER DOOR
11 820 EXTERNAL HALF GLASS
12 4398 EXTERNAL GLAZED DOOR
WINDOW SCHEDULE
MARK HEIGHT WIDTH TYPE REMARKS
W1 1800 610 AWNING WINDOW
W2 1800 610 AWNING WINDOW
W3 1800 610 AWNING WINDOW
W4 1800 2050 AWNING WINDOW CUSTOM WINDOW
W5 1200 1450 AWNING WINDOW
W6 1200 1450 AWNING WINDOW OPAQUE
W7 2100 1450 SLIDING DOOR
W8 2100 1810 AWNING WINDOW
W09 1800 1210 AWNING WINDOW
W10 1800 1210 AWNING WINDOW
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
Project:
Client name:
Drafted by: Approved by:
DOOR AND WINDOWSCHEDULES
PDH20010 04
20.04.2021
PLANNING
04
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
J. COAD & S. DOBBY
A.C.M.T.L.H.
FLOOR25300
CEILING
240
0
BO
UND
AR
Y
BO
UND
AR
Y
E.S.L.
F.S.L.
F.
22.5°
F.
45.0°
45.0°
FLOOR25300
CEILING
240
0
BO
UND
AR
Y
E.S.L.
F.S.L.
W10 W09
22.5°
1:205.00%1:14
7.03%
1 : 100
NORTHERN ELEVATION
1 : 100
EASTERN ELEVATION
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
1 : 100
A.C.M.T.L.H.
ELEVATIONS
PDH20010 -05
20.04.2021
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
PLANNING
J. COAD & S. DOBBY
04
DOORS AND WINDOWS TO BESEALED IN ACCORDANCE WITHNCC 2019 PART 2 3.12.3
ROOF FRAMING PREFABRICATED ROOF TRUSSES @ 900 CRS MAX BRACING BY OTHERS
ROOF CLADDINGCOLORBOND CUSTOM ORB TO CLIENTS SPECS.
BRICKWORK SELECTED FIRED CLAY FACE BRICKS. RAKED JOINTS, STRETCHER BOND REFER ENGINEER FOR ARTICULATION JOINTS ALL MASONRY TO COMPLYWITH NCC 2019 PART 3.3
WALL CLADDING INSTALL AND COAT TO MANUFACTURERS SPECIFICATIONS.
FLOOR25300
CEILING
240
0
BO
UND
AR
Y
E.S.L.
F.S.L.
W6 W5
F.
22.5°
W8 W7
FLOOR25300
CEILING
240
0
E.S.L.
F.S.L.414
BO
UND
AR
YW4 W3 W2 W1B
OUND
AR
Y
22.5°
45.0°
45.0°
4561
1 : 100
WESTERN ELEVATION
1 : 100
SOUTHERN ELEVATION
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
1 : 100
A.C.M.T.L.H.
ELEVATIONS
PDH20010 -06
20.04.2021
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
PLANNING
J. COAD & S. DOBBY
04
CONCRETE LANDING
ROOF FRAMING PREFABRICATED ROOF TRUSSES @ 900 CRS MAX BRACING BY OTHERS
ROOF CLADDINGCOLORBOND CUSTOM ORB TO CLIENTS SPECS.
DOORS AND WINDOWS TO BESEALED IN ACCORDANCE WITHNCC 2019 PART 2 3.12.3
WALL CLADDINGTO CLIENTS SPECS.
TEXTURE COATED BRICKWORKSELECTED FIRED CLAY BRICKSFLUSH JOINTS, STRETCHER BOND REFER ENGINEER FOR ARTICULATION JOINTS ALL MASONRY TO COMPLY WITH NCC 2019 PART 3.3
BRICKWORK SELECTED FIRED CLAY FACE BRICKS. RAKED JOINTS, STRETCHER BOND REFER ENGINEER FOR ARTICULATION JOINTS ALL MASONRY TO COMPLYWITH NCC 2019 PART 3.3
PANEL LIFT DOOR 2600 WIDE x 2100 HIGH CLADDING PANELS TO CLIENTSSPEC FIXED IN ACCORDANCE WITHMANUFACTURERS SPEC
WALL CLADDING INSTALL AND COAT TO MANUFACTURERS SPECIFICATIONS.
GUTTER
GUTTERD.P.
D.P.
D.P.
D.P.
D.P.
RID
GE
RIDGE
HIP
HIPHIP
HIPHIP
HIP
HIP
HIP
VALL
EY
VALL
EY
VALLEY
RID
GE
GABLE END
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
22.5° FALL 22.5° FALL
22.5
° FALL
22.5
° FALL
22.5
° FALL
22.5
° FALL
22.5° FALL
22.5° FALL22.5° FALL
22.5
° FALL
SKYLIGHT600X700
D.P.
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
Project:
Client name:
Drafted by: Approved by:
1 : 100
ROOF PLAN
PDH20010 07
20.04.2021
PLANNING
04
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
J. COAD & S. DOBBY
A.C.M.T.L.H.
1 : 100
ROOF PLAN
ROOF PLUMBING NOTES:
GUTTER INSTALLATIONTO BE IN ACCORDANCE WITH NCC 2019 PART 3.5.2.4. WITH FALL NO LESS THAN 1:100 FOR BOX GUTTERS1:500 FOR EAVES GUTTER
UNLESS FIXED TO METAL FASCIA EAVES GUTTER TO BE FIXED @ 1200 CRS MAX.
VALLEY GUTTERS ON A ROOF WITH A PITCH:A) MORE THAN 12.5° DEGREES - MUSTHAVE A WIDTH OF NOT LESS THAN 400mm AND ROOF OVERHANG OF NOT LESS THAN 150mm EACH SIDE OFVALLEYGUTTER. B) LESS THAN 12.5° DEGREES, MUST BE DESIGNED AS A BOX GUTTER.
LAP GUTTERS 75mm IN THE DIRECTION OF FLOW, RIVET & SEAL WITH AN APPROVED SILICONE SEALANT.
DOWNPIPE POSITIONS SHOWN ON THIS PLAN ARE NOMINAL ONLY. EXACT LOCATION & NUMBER OF D.P'S REQUIRED ARE TO BE IN ACCORDANCE WITH NCC 2019 PART 3.5.2.5 REQUIREMENTS. SPACING BETWEEN DOWNPIPES MUST NOT BE MORE THAN 12m & WITHIN 1.2m FROM A VALLEY GUTTER.
ADDITIONAL ROOF LOADNO SOLAR P.V. SYSTEM HAS BEEN ALLOWED FOR,NO SOLAR HOT WATER HAS BEEN ALLOWED FOR.
METAL ROOFMETAL SHEETING ROOF TO BE INSTALLED IN ACCORDANCE WITH NCC 2019 PART 3.5.1.3.REFER TO TABLE 3.5.3.1a FOR ACCEPTABLE CORROSION PROTECTION FOR SHEET ROOFING, REFER TO TABLE 3.5.1.1 FOR ACCEPTABILITY OF CONTACT BETWEEN DIFFERENT ROOFING MATERIALS.FOR FIXING, SHEET LAYING SEQUENCE, FASTENER FREQUENCY FOR TRANVERSE FLASHINGS AND CAPPINGS, ANTI CAPILLARY BREAKS, FLASHING DETAILS REFER TO NCC 2019 PART 3.5.1.5-3.5.1.7 ROOF PENETRATION FLASHING DETAILS.REFER TO NCC 2019 PART 3.5.1.5-3.5.1.7 ROOF SHEETING MUST OVERHANG MIN 35mm AS PER NCC 2019 PART 3.5.1.8
WEATHER PROOF OUTLET
GENERAL PURPOSE OUTLET (DOUBLE)
ELECTRICAL INDEX
240v SMOKE ALARMSECURITY LIGHT
SWITCH BOX
ONE-WAY SWITCH
TWO-WAY SWITCH
HANGING PENDANT
EXHAUST FAN, VENT TO OUTSIDE AIR, PROVIDE POWER
T.V. OUTLET
WEATHERPROOF WALL LIGHT
LIGHTING SWITCH TYPE
WALL OUTLETS
OTHER
Wi-Fi
HOTPLATE SAFETY CUT-OFF
HEAT PUMP
DENOTES CEILING HEIGHT
CEILING
XXXX
HEATING
HEAT PUMP, OUTDOOR UNIT
*INSTALL AS PER MANUFACTURERSSPECIFICATION
FOUR LIGHT TASTIC EXHAUST FAN, C/W DAMPER,EXHAUST TO OUTSIDE*
MANHOLEMH
O/H
O/H
O/H
O/H
S.B
.
HW
C
FR
W/M
H.P.
H.P.
NBN
2400
2400
24002400
2400
2400
2400
MH
DW MW
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
Project:
Client name:
Drafted by: Approved by:
1 : 100
ELECTRICAL/REFLECTEDCEILING PLAN
PDH20010 08
20.04.2021
PLANNING
04
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
J. COAD & S. DOBBY
A.C.M.B.K.S.
1 : 100
ELECTRICAL PLAN
IMPORTANT:PLEASE REFER TO ENERGY ASSESSMENT REPORT FOR FULL DETAILS.ENERGY ASSESSMENT IS BASED ON THE ABOVE ELECTRICAL LAYOUT AND TYPES AS NOTED IN THE REPORT.IF MORE PENETRATIONS ARE INCLUDED OR ANY OTHER ASPECT OF THE BUILDING IS MODIFIED, A NEW ENERGY ASSESSMENT WILL BE REQUIRED.
ARTIFICIAL LIGHTINGRESIDENCES TO BE IN COMPLIANCE WITH NCC2019 PART 3.12.5.5.
ARTIFICIAL LIGHTING MUST NOT EXCEED:• 5W/m2 FOR CLASS 1 RESIDENCE• 4W/m2 FOR VERANDAHS & BALCONIES• 3W/m2 FOR CLASS 10 GARAGE, STORAGE• REFER TO LIGHTING CALCULATOR FOR FURTHERDETAILS.
ELECTRICALALL ELECTRICAL WORKS TO BE CARRIED OUT BY A GRADE ELECTRICAL CONTRACTOR. ALL WORKS TO COMPLY WITH LOCAL AUTHORITIES AND A.S.3000
SMOKE ALARMS• ALL ALARMS TO BE
INTERCONNECTED WHERE MORE THAN ONE ALARM IS INSTALLED.
• TO BE INTERCONNECTED BETWEEN FLOORS WHERE APPLICABLE.
• SMOKE ALARMS TO BE LOCATED ON ALL FLOORS IN ACCORDANCE WITH NCC 2019 PART 3.7.5.2
HWC
S.B
.
H.P.
H.P.
D.P.
D.P.
D.P.
D.P. D
.P.
D.P.
ORG
I.O.
I.O.
I.O.
W/C
VAN.
SHRW/C
SINK
VAN.SHR
BATH
TR
CONNECT STORMWATER TO COUNCIL STORMWATER CONNECTION
CONNECT SEWER TO TASWATER SEWER CONNECTION
FALL
FALL
FALL
FALL
FALL
TAP
TAP
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
Project:
Client name:
Drafted by: Approved by:
1 : 100
GROUND FLOOR PLUMBINGPLAN
PDH20010 09
20.04.2021
PLANNING
04
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
J. COAD & S. DOBBY
A.C.M.B.K.S.
1 : 100
PLUMBING PLAN
PLUMBING NOTES:ALL DRAINAGE WORK SHOWN IS PROVISIONALONLY AND IS SUBJECT TO AMENDMENT TOCOMPLY WITH THE REQUIREMENTS OF THE LOCALAUTHORITIES. ALL WORK IS TO COMPLY WITH THE REQUIREMENTS OF AS 3500.2018 & THE NATIONAL CONSTRUCTION CODE. AND MUST BE CARRIED OUT BY A LICENCEDTRADESMAN ONLY.
LEGEND OF DIAMETERSTROUGH = 50mmSINK = 50mm BATH = 40mmBASIN = 40mm SHOWER = 50mm WC = 100mm SEWER = 100mm uPVC ORG = OVERFLOW RELIEF GULLY VENT = 50mm DP = 90mmDOWNPIPE STORMWATER = 90mm uPVC
THE INSTALLATION OF WATER PIPE LINES, USE POLY OR COPPER PIPE, MUST COMPLY WITH AS/NZS 3500.2018. MAIN COLD WATER LINE FROM METER TO HOUSETO BE DN 25mm WITH DN 16mm BRANCHES & HOT WATER MAIN LINES TO BE DN 20mm WITH DN 16mm BRANCHES TO FIXTURES, ALL OTHER PRODUCTS USED ARE TO COMPLY WITH THE REQUIREMENTS OF AS/NZS 3500.2018.
HOT WATER INSTALLATION SHALL DELIVER HOT WATER TO ALL SANITARY FIXTURES USED FOR PERSONAL HYGIENE AT 50deg C, KITCHEN SINK & LAUNDRY SHALL BE 60deg C TO COMPLY WITH REQUIREMENTS OF AS/NZS 3500.2018.
AT THE PROPERTY BOUNDARY, AN APPROVEDBACKFLOW PROTECTION VALVE IS TO BE FITTED BEFORE EXTENDING THE DOMESTIC SUPPLY TO THE DWELLING.
FINAL PITS LOCATION AND NUMBER TO BE CONFIRMED ON SITE TO ENSURE SURFACE WATER IS REMOVED FROM AROUND HOUSE.
300X300 EVERHART SURFACE DRAINAGE PIT
450x450 SURFACE DRAINAGE PITAT LOCATION OF DRIVEWAY/BATTERS
HOT WATER CYLINDER TO BE INSTALLED AS PER NCC 2019 VOL 3
Hotondo Homes Craig Ellis148 New Town Road, New Town 7008Ph: 0400 653 681
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p(l)+ 03 6332 3790 160 New Town Road, New Town, Hobart 7008p(h)+ 03 6228 [email protected] primedesigntas.com.au
A.C.M.T.L.H.
PERSPECTIVES
PDH20010 -10
20.04.2021
PROPOSED NEW RESIDENCE1 (LOT 25) VENERABLE DRIVEROKEBY
PLANNING
J. COAD & S. DOBBY
04