differential pressure transmitter dpw201
TRANSCRIPT
1
n Analog voltage or 2-wire 4~20 mA output
n High pressure ranges available
n Standard accuracy : ±0.5% of span ±2Pa High accuracy : 1% of span
n Output can be assigned to DP or Air Velocity or Air Flow
n IP65 protection
n Dual row backlit LCD option
n Parameter configuration and calibration - Using PC & USB to serial converter DCC501 - Using handheld configurator (Order code: 2863)
n Heartbeat LED
n Duct mount option available for static pressure measurement
n Wall mount with rear side cable entry option available on request
n Field selectable ranges
n Convenient installation with 2-part housing with fixed back and removable electronics
n Enclosure opens with 1/4 turn rotation screws
n Provision for 1/2" conduit clamping (for US)
DIFFERENTIAL
PRESSURE /
AIR VELOCITY /
AIR FLOW,
MULTI-RANGE,
HEARTBEAT LED,
IP65
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
www.radix.co.in
DPW201 measures Air Flow and Air Velocity using Differential Pressure measurement. It generates an analog output that can be assigned to DP or Air Velocity or Air Flow.
It is available with; a) single loop-powered 4~20 mA output; b) single loop-powered 4~20 mA / 0~10V output (field selectable); c) dual, isolated, loop-powered, 4~20 mA outputs.
n Measurement of very low pressure applications such as hospitals, fume hoods, computer rooms etc.
n HVAC/building monitoring
n Greenhouse monitoring
n Process system monitoring
n Air economizers
n Duct mount application
ABOUT DPW201
APPLICATIONS
CONFIGURATOR FOR DPW201
PC Configurator
DCC501 USB to Serial converter can be used to program the parameters. The Programmer DCC501 must be purchased separately.
USB INTERFACE
DCC501
USB to Serial converter
Handheld Configurator
Handheld Configurator can be used to configure and calibrate the parameters. The Configurator must be purchased separately.
Handheld Configurator
2www.radix.co.in
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
3
All specifications at ambient of 25 °C, 24VDC unless specified otherwise
SPECIFICATIONS
MEASURED PARAMETERS
Differential Pressure
Maximum pressure range See Table 1
Units Pa, mmWC, mbar, inWC, inHG, PSI, mmHG, KPa
Over pressure ±1PSI
Current consumption 50mA max
Service Air and non-combustible, compatible gases
Accuracy See Table 2 & 3
Stability ±1% span / year
Measurement resolution 0.1Pa for ±125Pa, 0~125Pa, ±250Pa, 0~250 Pa ranges with high accuracy 1Pa for all ranges with standard accuracy
Air Flow
Maximum air flow range -999~9999 KCFM OR -999~9999 KM3H
Units CFM (Standard cubic feet per minute)
M3H (Cubic meter per hour)
K-factor User configurable
Area User configurable
Accuracy ±5 % of span
Air Velocity
Maximum air velocity range See Table 1
Units FPM (Standard feet per minute)
MPS (Meter per second)
K-factor User configurable
Accuracy ±5 % of span
POWER SUPPLY
Supply voltage For 4~20 mA output, 12~30 VDC
For 0~10 VDC output, 18~30 VAC/DC
Power consumption For 4~20 mA output, <40 mW
For 0~10 VDC output, <450 mW
Supply voltage effect ± 0.002% of span / V
Supply ripple effect ± 0.005% of span 50/60 hz, 5 Vp - p
INDICATION
Display Dual row LCD display
Digits Upper row, 6-digit, 10.5mm height, with unit indication
Lower row, 7-digit, 6.94mm height, with unit indication
Backlight Enable/Disable option
Status indication Healthy and failure conditions
Display resolution 0.1 Pa/1 Pa (See Table 2 & 3)
www.radix.co.in
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
4
All specifications at ambient of 25 °C, 24VDC unless specified otherwise
SPECIFICATIONS
OUTPUT
Analog output current 1 or 2, isolated 4~20 mA loop powered output with load 500 Ω @ 24 V DC
Mutual isolation between loop powered output 1500 V AC RMS, 50 hz / 1 minute
Analog output voltage 0~10 V DC, Load > 1K
(0~1 V DC, 0~5 V DC Outputs available on request)
Output resolution (For 4~20mA or 0~10V output)
0.025% of span OR corresponding to display/measurement resolution (0.1 or 1Pa), whichever is greater (minimum 4 µA or 2.5 mV)
CALIBRATION, CONFIGURATION
Zero & span a) Handheld configurator
b) Through PC using serial converter (To be ordered separately)
TEMPERATURE, HUMIDITY
Enviornment With display Without display
Ambient, storage -20~70 °C (-68~158 °F) -40~70 °C (-104~158 °F)
Ambient, operation -5~60 °C (-41~140 °F) -5~60 °C (-41~140 °F)
Media Air & non combustible, compatible gases
Relative humidity 0~95% RH, non-condensing
ELECTRICAL CONNECTIONS
Screw type suitable for cable 14~22AWG
Torque 4kgf.cm/M2.5
Mounting orientation Not position sensitive
MECHANICAL
Dimensions See Fig 3, Fig 4
Mounting Wall mount / Duct mount
Material Polycarbonate
Protection IP65
Conduit connection Provision for 1/2" conduit clamping
Tubing size
Wall surface mount 5mm ID, Max OD 9mm
Duct mount 14mm ID, Max OD 16mm
PARAMETERS SET VIA DIP
Range
Backlight
Polarity : Unipolar, Bipolar
Display assignment
www.radix.co.in
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
5
CONNECTION DIAGRAM
Note : Each DPW201 should have a separate winding or transformer
24 VAC Connection
-
-
DPW201-1
24 VAC
24 VAC
230 VAC
230 VAC DPW201-2
Vs+
Vs+
Vs
Vs
OP+
OP+
OP
OP
-
-
-
-
PID CONTROLLER
VIN+
VIN+
VIN -
VIN -
+ -
1
DPW201
Isolated Dual 4~20 mA output
V1
24 VDC POWERSUPPLY
Analog Current Output1 Receiver
Analog Current Output2 Receiver
I1 V2 I22 3 4
+ -24 VDC POWERSUPPLY
PLC/Scanner/
Controller1
V1Loop powered
Output 14~20 mA
4~20 mA
DPW201
Loop powered
Output 2
1.5 KV isolation
VTX
VTX
IIN
IIN
I1
V2
I2
PLC/Scanner/
Controller2
Loop supply from PLC
Fig 1VOLTAGE OUTPUT
Fig 2SINGLE/DUAL, 4~20 mA, LOOP POWERED
1
DPW201
24VAC/DC COM Vout2 3
24 VDC/VAC PowerSupply
+ + Analog Voltage
ReceiverOutput
www.radix.co.in
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
6
TABLE 1 - DP AND VELOCITY RANGES
User selectable ranges (by DIP switches)
Note1 : Unipolar ranges : R1, R2, R3, R4, R5, R6, R7 Bipolar ranges : R8, R9, R10, R11, R12, R13, R14
Note2 : Range Configuration : Example Range code is R1. User can select 25, 40, 50, 125 range using DIP switch. Any range from 0~125Pa can be set using Configurator HHC202 or DCC501 or internal keys if DIP switch off.
www.radix.co.in
Order Code Pa mmWC mbar inWC mmHg PSI inHg KPaAir Velocity
in FPMAir Velocity
in mps
2882 XXXXXR1
12, 40, 50, 125
1.2, 4.0,5.0, 12.5
0.12, 0.40, 0.50, 1.25
0.05, 0.16, 0.20, 0.50
0.09, 0.30, 0.37, 0.94
0.002, 0.005, 0.007, 0.018
0.004, 0.011, 0.014, 0.036
0.012, 0.040, 0.050, 0.125
878,1604,1794,2836
4.46,8.15,9.11,14.41
2882 XXXXXR8
±12, ±40, ±50, ±125
±1.2, ±4.0, ±5.0, ±12.5
±0.12,±0.40, ±0.50, ±1.25
±0.05, ±0.16, ±0.20, ±0.50
±0.09, ±0.30, ±0.37, ±0.94
±0.002, ±0.005, ±0.007, ±0.018
±0.004, ±0.011, ±0.014, ±0.036
±0.012, ±0.040, ±0.050, ±0.125
±878,±1604,±1794,±2836
±4.46,±8.15,±9.11,±14.41
2882 XXXXXR2
25,100,200,250
2.5,10.0,20.0,25.0
0.25,1.00,2.00,2.50
0.10,0.40,0.06,1.00
0.19,0.75,1.50,1.88
0.004,0.014,0.029,0.036
0.007,0.030,0.059,0.073
0.025,0.100,0.200,0.250
1268,2537,3588,4011
6.44,12.89,18.23,20.37
2882 XXXXXR9
±25,±100,±200,±250
±2.5,±10.0,±20.0,±25.0
±0.25,±1.00,±2.00,±2.50
±0.10,±0.40,±0.06,±1.00
±0.19,±0.75,±1.50,±1.88
±0.004,±0.014,±0.029,±0.036
±0.007,±0.030,±0.059,±0.073
±0.025,±0.100,±0.200,±0.250
±1268,±2537,±3588,±4011
±6.44,±12.89,±18.23,±20.37
2882 XXXXXR3
300, 350, 400,500
30.0, 35.0, 40.0, 51.0
3.00, 3.50, 4.00, 5.00
1.20, 1.41, 1.61, 2.01
2.25, 2.63, 3.00, 3.75
0.043, 0.050, 0.058, 0.072
0.088, 0.103, 0.118, 0.148
0.300,0.350, 0.400, 0.500
4394,4746,5074,5673
22.32,24.11,25.77,28.82
2882 XXXXXR10
±300, ±350, ±400, ±500
±30.0, ±35.0, ±40.0, ±50.0
±3.00, ±3.50, ±4.00, ±5.00
±1.20, ±1.41, ±1.61, ±2.01
±2.25, ±2.63, ±3.00, ±3.75
±0.043, ±0.050, ±0.058, ±0.072
±0.088, ±0.103, ±0.118, ±0.148
±0.300, ±0.350, ±0.400, ±0.500
±4394,±4746,±5074,±5673
±22.32,±24.11,±25.77,±28.82
2882 XXXXXR4
250, 600, 750, 1000
25.0, 60.0, 75.0, 100.0
2.50, 6.00, 7.50, 10.00
1.00, 2.41, 3.01, 4.01
1.88, 4.50, 5.63, 7.50
0.036, 0.087, 0.109, 0.145
0.073, 0.177, 0.221, 0.295
0.250, 0.600, 0.750, 1.000
4011,6214,6948,8023
20.37,31.57,35.29,40.75
2882 XXXXXR11
±250, ±600, ±750, ±1000
±25.0, ±60.0, ±75.0, ±100.0
±2.50, ±6.00, ±7.50, ±10.00
±1.00, ±2.41, ±3.01, ±4.01
±1.88, ±4.50, ±5.63, ±7.50
±0.036, ±0.087, ±0.109, ±0.145
±0.073, ±0.177, ±0.221, ±0.295
±0.250, ±0.600, ±0.750, ±1.000
±4011,±6214,±6948,±8023
±20.37,±31.57,±35.29,±40.75
2882 XXXXXR5
800, 1200, 1500, 2000
80.0, 120.0, 150.0, 200.0
8.00, 12.00, 15.00, 20.00
3.21, 4.82, 6.02, 8.03
6.00, 9.00, 11.30, 15.00
0.116, 0.174, 0.218, 0.290
0.236, 0.354, 0.443, 0.591
0.800, 1.200, 1.500, 2.000
7176,8789,9826,11346
36.45,44.64,49.91,57.64
2882 XXXXXR12
±800, ±1200, ±1500, ±2000
±80.0, ±120.0, ±150.0, ±200.0
±8.00, ±12.00, ±15.00, ±20.00
±3.21, ±4.82, ±6.02, ±8.03
±6.00, ±9.00, ±11.30, ±15.0
±0.116, ±0.174, ±0.218, ±0.290
±0.236, ±0.354, ±0.443, ±0.591
±0.800, ±1.200, ±1.500, ±2.000
±7176,±8789,±9826,±11346
±36.45,±44.64,±49.91,±57.64
2882 XXXXXR6
2500, 3000, 3500, 4000
250.0, 300.0, 350.0, 400.0
25.00, 30.00, 35.00, 40.00
10.00, 12.00, 14.10, 16.10
18.80, 22.50, 3.38, 30.00
0.363, 0.435, 0.508, 0.580
0.738, 0.886, 1.030, 1.180
2.500, 3.000, 3.500, 4.000
12686,13896,15010,16046
64.44,70.59,76.25,81.51
2882 XXXXXR13
±2500, ±3000, ±3500, ±4000
±250.0, ±300.0, ±350.0, ±400.0
±25.00, ±30.00, ±35.00, ±40.00
±10, ±12, ±14.1, ±16.1
±18.80, ±22.50, ±3.38, ±30.00
±0.363, ±0.435, ±0.508, ±0.580
±0.738, ±0.886, ±1.030, ±1.180
±2.500, ±3.000, ±3.500, ±4.000
±12686,±13896,±15010,±16046
±64.44,±70.59,±76.25,±81.51
2882 XXXXXR7
4250, 5000, 8000, 10000
425.0, 500.0, 800.0, 1000.0
42.50, 50.00, 80.00, 100.00
17.10, 20.10,32.10, 40.10
31.90, 37.50, 60.00, 75.00
0.616, 0.725, 1.160, 1.450
1.260, 1.480, 2.360, 2.95
4.250,5.000, 8.000, 10.000
16540,17940,22693,25372
84.03,91.13,115.28,128.89
2882 XXXXXR14
±4250, ±5000, ±8000, ±10000
±425.0, ±500.0, ±800.0, ±1000.0
±42.50, ±50.00, ±80.00, ±100.00
±17.10, ±20.1,±32.1, ±40.1
±31.90, ±37.50, ±60.00, ±75.00
±0.616, ±0.725, ±1.160, ±1.450
±1.260, ±1.480, ±2.360, ±2.950
±4.250, ±5.000, ±8.000, ±10.000
±16540,±17940,±22693,±25372
±84.03,±91.13,±115.28,±128.89
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
7www.radix.co.in
ACCURACY & RESOLUTION
Pa
mmWC
mbar
inWC
PSI
inHg
mmHg
KPa
Unit
Typical Accuracy
At 30 °C
(% span)
± 0.5% ± 2 Pa
± 0.5% ± 0.02 KPa
± 0.5% ± 0.2 mmWC
± 0.5% ± 0.02 mbar
± 0.5% ± 0.008 inWC
± 0.5% ± 0.0003 PSI
± 0.5% ± 0.0007 inHG
± 0.5% ± 0.016 mmHG
Worst Case
Accuracy
(°C / % span)
Min span
± 1.5% of reading ±3 Pa
± 1.5% of reading ±0.03 KPa
10% of span
10% of span
± 1.5% of reading ±0.3 mmWC 10% of span
± 1.5% of reading ±0.03 mbar 10% of span
± 1.5% of reading ±0.012 inWC 10% of span
± 1.5% of reading ±0.00045 PSI 10% of span
± 1.5% of reading ±0.0008 inHG
± 1.5% of reading ±0.024 mmHG
10% of span
10% of span
Display/Measurement
Resolution
1
0.01
0.1
0.01
0.01
0.001
0.001
0.01
UnitTypical Accuracy At 30 °C (% span)
Min span Display/Measurement Resolution
Pa ±1% 10% of span 0.1/1
mmWC ±1% 10% of span 0.01/0.1
mbar ±1% 10% of span 0.001/0.01
inWC ±1% 10% of span 0.001/0.01
PSI ±1% 10% of span 0.0001/0.001
inHg ±1% 10% of span 0.0001/0.001
mmHg ±1% 10% of span 0.001/0.01
KPa ±1% 10% of span 0.001/0.01
TABLE 2 - Standard Accuracy : Ranges - R1 To R14
TABLE 3 - High Accuracy : Ranges - R1, R2, R8, R9
INSTALLATION
Removable front with electronics
Fixed back for cabling
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
8www.radix.co.in
DIMENSIONS mm
Fig 3 : Wall Mount
Fig 5 : Wall mount with rear cable entry
73
89.6
0
82
73
89.6
0
82
70
41.4
0
Front View
Front View
Rear View
Rear View
Side View
Side View
Bottom View
Bottom View
89.6
0
41.40
12
41.4
0
1 or 2 Cable Gland EntryM16 X 1.5 or PG7
73
89.6
0
82
Front View
Rear View
Side View Bottom View
Fig 4 : Duct mounting option available for static pressure measurement1
4 50
89
.60
280.7
240.2
40.5
12
80
40.5
0
28
0.7
0
24
0.2
0
Cable Gland Entry
M16 X 1.5 or PG7
60
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
73
89.6
0
82
BOTTOM VIEWISOMETRIC VIEW
ISOMETRIC VIEW
FRONT VIEW SIDE VIEWBACK VIEW
89.6
0
42.1
63
70
41.4
0
12
41.9
Cable Gland Entry PG7
9
Example 2882 1 1 2 2 1 1 1 R1
Order code 2882
Transmitter Selection1 Only DP
2 Universal DP / Air Flow / Air Velocity
Housing Type
1 Wall mount (see Fig 3)
2 Duct mount (see Fig 4)
3 Wall mount with rear cable entry (see Fig 5)
LCD Display1 None
2 Provided
Configuration
1 Single loop powered current output
2 Field-selectable voltage / current output
3 Dual Isolated loop powered current outputs
Pressure Unit
1 Pa
2 mmWC
3 mbar
4 inWC
5 mmHg
6 PSI
7 inHg
Accuracy
1Standard Accuracy: ±0.5% span ±2Pa See Table2 (All ranges)
2High Accuracy: ±1% span See table 3 (Ranges R1, R2, R8, R9 only)
Test & calibration report 1 No #
2 Yes**
Pressure Range(see Table1)*
R1 12, 40, 50, 125 Pa
R2 25,100, 200, 250 Pa
R3 300, 350, 400, 500 Pa
R4 250, 600, 750, 1000 Pa
R5 800, 1200, 1500, 2000 Pa
R6 2500, 3000, 3500, 4000 Pa
R7 4250, 5000, 8000, 10000 Pa
R8 ±25, ±40, ±50, ±125 Pa
R9 ±135, ±150, ±175, ±250 Pa
R10 ±300, ±350, ±400, ±500 Pa
R11 ±250, ±600, ±750, ±1000 Pa
R12 ±800, ±1200, ±1500, ±2000 Pa
R13 ±2500, ±3000, ±3500, ±4000 Pa
R14 ±4250, ±5000, ±8000, ±10000 Pa
EXAMPLE
2882 1 1 2 2 1 1 1 R1
USB-to-Serial Converter
Handheld Configurator
Product
2555 0
2863
DCC501
HHC202
Model Order Code
CONFIGURATORS* Non-standard ranges, eg ±60 Pa, can be provided. Contact sales.# Certificate Of Conformance is included** Chargeable
LCD Display : Provided
Housing type : Surface wall mount
Transmitter selection : Only DP
Pressure Unit : Pa
Standard Accuracy : 0.5% of FS +_2Pa
Test & calibration report : No
Pressure range : 125 Pa
Configuration : Field-selectable voltage / current output
www.radix.co.in
ORDERING INFORMATION
DIFFERENTIAL PRESSURE TRANSMITTERDPW201
10
CA
T#694
R6/T
** To be purchased separately.
** To be purchased separately.
ITEM ORDER CODE
Averaging flow sensor, 3-5/32" (8.02 cm) insertion length. 2960 1
Averaging flow sensor, 5-13/32" (13.73 cm) insertion length 2960 2
Averaging flow sensor, 7-21/32" (19.55 cm) insertion length 2960 3
Averaging flow sensor, 9-29/32" (25.26 cm) insertion length 2960 4
Averaging flow sensor, 12-1/2" (31.75 cm) insertion length 2960 5
Averaging flow sensor, 14-3/4" (37.47 cm) insertion length 2960 6
Averaging flow sensor, 17-1/8" (43.50 cm) insertion length 2960 7
Averaging flow sensor, 19-13/32" (49.29 cm) insertion length 2960 8
Averaging flow sensor, 21-21/32" (55.01 cm) insertion length 2960 9
Averaging flow sensor, 23-29/32" (60.72 cm) insertion length 2960 10
**Accessories for Air Velocity or Air Flow measurement
AVERAGING FLOW SENSORS
PITOT TUBE
Pitot tubes with varying length to be checked
ITEM ORDER CODE
Ellipsoidal tip Pitot tube, 0.2 meter insertion length 2961 1
Ellipsoidal tip Pitot tube, 0.3 meter insertion length 2961 2
Ellipsoidal tip Pitot tube, 0.48 meter insertion length 2961 3
Ellipsoidal tip Pitot tube, 0.8 meter insertion length 2961 4
Ellipsoidal tip Pitot tube, 1.0 meter insertion length. 2961 5
Ellipsoidal tip Pitot tube, 1.22 meter insertion length 2961 6
Ellipsoidal tip Pitot tube, 1.52 meter insertion length 2961 7
Ellipsoidal tip Universal Pitot tube, attaches to any length of 3/4" sch. 40 pipe
2961 8
RADIX ELECTROSYSTEMS PVT LTDEL-135/136/137, Electronics Zone, TTC Indl. Area, MIDC, MahapeNavi Mumbai - 400 710, India+ 91 22 42537707 · [email protected]
NQ
UIR
IES Instruments: [email protected]
Sensors: [email protected]
Gauges: [email protected]
Automation: [email protected]
Level: [email protected]: [email protected]
www.radix.co.in
ORDERING INFORMATION