disclaimer for review of plansnotice.sfplanning.org/2016-012089var.pdf · 2017. 11. 8. · 101...
TRANSCRIPT
-
Disclaimer for Review of Plans The San Francisco Planning Code requires that the plans of certain proposed projects be providedto members of the public prior to the City s approval action on the project. Accordingly, anyimages of plans featured on this website are provided for the primary purpose of facilitatingpublic input prior to the City s action. The City and County of San Francisco does not own thecopyright to these images. Please be aware that the unauthorized reproduction, distribution, oralteration of these images may result in a violation of Federal Copyright Law (17 U.S.C.A.Sections 101 et seq.) and that any party who seeks to reproduce or alter these images does so at hisor her own risk.
Additionally, plans provided on this website are limited to site plans, elevations and/or sectiondetails (floor plans and structural details may not be included). These are DRAFT PLANS beingprovided for public review PRIOR to the City’s approval action on the project. Final plans maydiffer from those that are currently available for review.
Memo
-
中文詢問請電: 415.575.9010 | Para Información en Español Llamar al: 415.575.9010 | Para sa Impormasyon sa Tagalog Tumawag sa: 415.575.9121
1650 Miss ion Street , Sui te 400 • San Franc isco, CA 94103 • Fax (415) 558-6409
NOTICE OF PUBLIC HEARING Hearing Date: Wednesday, December 6, 2017 Time: Not before 9:00 AM Location: City Hall, 1 Dr. Carlton B. Goodlett Place, Room 408 Case Type: Variance Hearing Body: Zoning Administrator
P R O P E R T Y I N F O R M A T I O N A P P L I C A T I O N I N F O R M A T I O N
The proposal is a horizontal and vertical addition to an existing, 3-story residential building containing 2 Dwelling Units. The proposal would excavate under the existing structure and lift the existing floor plates approximately 3 feet, 6 inches, creating a new fourth floor. The project would add a two-car garage, with two garage doors measuring 8 feet wide (each). A new roof deck accessible via a roof hatch is included in the proposal. PER SECTION 134 OF THE PLANNING CODE, a rear yard of approximately 15 feet is required for the subject property. The project proposes a horizontal and vertical addition within a portion of the side yard and the rear yard. A portion of the horizontal and vertical addition encroaches into the required rear yard by approximately 6 feet, 8 inches. Therefore, a variance is required.
Project Address: 33-35 Aladdin Terrace Cross Street(s): Taylor/Mason Streets Block /Lot No.: 0100/021B Zoning District(s): RM-1/ 40-X Area Plan: N/A
Case No.: 2016-012089VAR Building Permit: 201609026778 Applicant: Blake Evans Telephone: (415) 346-9990 E-Mail: [email protected]
FOR MORE INFORMATION, PLEASE CONTACT PLANNING DEPARTMENT STAFF: Planner: Nicholas Foster Telephone: (415) 575-9167 E-Mail: [email protected]
P R O J E C T D E S C R I P T I O N
ARCHITECTURAL PLANS: The site plan and elevations of the proposed project are available on the Planning Department’s website at: http://notice.sfplanning.org/2016-012089VAR.pdf Members of the public are not required to provide personal identifying information when they communicate with the Commission or the Department. All written or oral communications, including submitted personal contact information, may be made available to the public for inspection and copying upon request and may appear on the Department’s website or in other public documents.
A D D I T I O N A L I N F O R M A T I O N
mailto:[email protected]
-
GENERAL INFORMATION ABOUT PROCEDURES
HEARING INFORMATION
You are receiving this notice because you are either a property owner or resident that is adjacent to the proposed project or are an interested party on record with the Planning Department. You are not required to take any action. For more information regarding the proposed work, or to express concerns about the project, please contact the Applicant or Planner listed on this notice as soon as possible. Additionally, you may wish to discuss the project with your neighbors and/or neighborhood association, as they may already be aware of the project.
Persons who are unable to attend the public hearing may submit written comments regarding this application to the Planner listed on the front of this notice, Planning Department, 1650 Mission Street, Suite 400, San Francisco, CA 94103, by 5:00 pm the day before the hearing. These comments will be made a part of the official public record and will be brought to the attention of the person or persons conducting the public hearing.
Comments that cannot be delivered by 5:00 pm the day before the hearing may be taken directly to the hearing at the location listed on the front of this notice. Comments received at 1650 Mission Street after the deadline will be placed in the project file, but may not be brought to the attention of the Zoning Administrator at the public hearing.
BUILDING PERMIT APPLICATION INFORMATION
Pursuant to Planning Code Section 311, the Building Permit Application for this proposal may also be subject to notification of property owners and residents within 150-feet of the subject property.
APPEAL INFORMATION
An appeal of the approval (or denial) of a Variance application by the Zoning Administrator may be made to the Board of Appeals within 10 calendar days after the Variance Decision Letter is issued by the Zoning Administrator.
An appeal of the approval (or denial) of a building permit application by the Planning Commission may be made to the Board of Appeals within 15 calendar days after the building permit is issued (or denied) by the Director of the Department of Building Inspection.
Appeals must be submitted in person at the Board's office at 1650 Mission Street, 3rd Floor, Room 304. For further information about appeals to the Board of Appeals, including current fees, contact the Board of Appeals at (415) 575-6880.
-
DN
A101 1
A1011
CL
A101 1
0
A3
NameElevation
1A101
Room name
101150 SF
TYPTYP ?
1A101
01
110AGP01
?
1i
A1011
P01
E01
F01
ALADDIN TERRACE
33-35 ALADDIN TERRACE4 STORIES
870 UNION STREET
870 UNION STREETUNDER PERMIT#
2015.1113.2622 AND2015.1113.2623)
1914 TAYLOR STREET
1916-1918 TAYLOR STREET
15ALADDIN
LOT
DEPT
H(E
) 54'
-9"
LOT WIDTH(E) 25'-9"
PROPERTY LINE
AREA OF WORK.SEE SITE PLANSA002A & A002B
PROPERTYLINE
1926-1930 TAYLOR STREET(E) 4 STORY
1920-1924 TAYLOR STREET(E) 3 STORY
3 STORIES+/- 40'-7"
+/- 43'-0"
+/- 42'-0"
878-882 UNIION(E) 3 STORY
+/- 56'-0"
UNION ST
FILBERT ST
TAYLOR ST
KENT ST
MASON
ST
ALADDIN TER.
PROJECT LOCATION
GREEN ST
VALPARAISO ST
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990LOCATIONMAP
SCOPE OF WORK INCLUDES THE REMOVAL OF EXISTINGINTERIOR WALLS, DOORS, FINISHES AND FIXTURES ANDCONSTRUCTION OF NEW INTERIOR WALLS, DOORS, FINISHESAND FIXTURES. SCOPE INCLUDES ADDITION OF NEW LIVINGLEVEL AT STREET GRADE WITH NEW GARAGE, INFILL OFEXISTING SIDE SETBACK AND INFILL OF EXISTING LIGHTWELL.EXTERIOR WORK INCLUDES NEW WINDOWS, DOORS ANDROOF DECK AT TOP OF BUILDING.
SCOPE OF WORK TO INCLUDE A FULLY AUTOMATICSPRINKLER SYSTEM. NFPA STANDARD SYSTEM TYPE TO BEDETERMINED BY S.F.F.D.
ADDRESS:
LOT SIZE:STORIES:
AREA OF LARGESTSINGLE STORY:
ZONING:CONSTRUCTION TYPE:
SPRINKLER SYSTEM:
OCCUPANCY TYPE:USE:
AREA OF WORK:FLOOR LEVELS AFFECTED:
PROPOSED PLOT PLANABBREVIATIONS
&@C±P#A.F.F.AL.ALUM.ANOD.APPROX.A.R.ARCH.A/VBD.BLDG.BLK.BLKG.B.O.BTWN.CAB.CLG.CLKG.CLOS.CLR.CMUC.O.COL.CONC.CONN.CONSTR.CONT.CORR.CTR.CTSK.DBL.DEPT.DET.D.F.DIA.DIM.DISP.DN.D.O.DR.DWG.DWR.(E)EEA.E.J.E.ELEC.ELEV.EMER.ENGR.E.P.EQ.EQPT
ANDATCENTERLINEPLUS OR MINUSPROPERTY LINEPOUND OR NUMBERABOVE FINISH FLOORALUMINUMALUMINUMANODIZEDAPPROXIMATEAS REQUIREDARCHITECTURALAUDIO/VISUALBOARDBUILDINGBLOCKBLOCKINGBOTTOM OFBETWEENCABINETCEILINGCAULKINGCLOSETCLEARCONCRETE MASONRY UNITCLEAN OUTCOLUMNCONCRETECONNECTIONCONSTRUCTIONCONTINUOUSCORRIDORCENTERCOUNTERSUNKDOUBLEDEPARTMENTDETAILDRINKING FOUNTATINDIAMETERDIMENSIONDISPENSERDOWNDOOR OPENINGDOORDRAWINGDRAWEREXISTINGEASTEACHEXPANSION JOINTELEVATIONELECTRICALELEVATIONEMERGENCYENGINEERELECTRIAL PANEL BOARDEQUALEQUIPMENT
EXISTINGEXTERIOREXTRUSIONFIRE ALARMFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIRE HOSE CABINETFINISHFLOORFLUORESCENTFACE OF CONCRETEFACE OF FINISHFACE OF PLYWOODFACE OF STUDFIRE RETARDENT or FIRE RATEDFOOT or FEETFURRINGFUTUREFIELD VERIFYGAUGEGALVANIZEDGENERAL CONTRACTORGENERALGYPSUM WALL BOARDGYPSUMHOSE BIBHANDICAPPEDHOLLOW METALHORIZONTALHOURHEIGHTHOT WATER DISPENSERHOT WATER HEATERINSULATIONINTERIORJANITORJANITOR'S CLOSETJOINTKITCHENLAMINATELAVATORYMAXIMUMMEDIUM DENSITY FIBERBOARDMECHANICALMEMBRANEMETALMEZZANINEMANUFACTURERMINIMUMMISCELLANEOUSMASONRY OPENINGMOUNTEDMOUNTINGMULLIONNEWNORTHNOT IN CONTRACTNUMBERNOMINAL
NOT TO SCALEOVERALLON CENTEROFFICEOUTSIDE FACE OF STUDPLASTIC LAMINATEPLYWOODPAIRPOINTPARTITIONRISERREFERENCEREFIGERATORREQUIREDREINFORCED FIBERGLASS PANELROOMROUGH OPENINGSOUTHSEE CIVIL DRAWINGSSCHEDULESECTIONSEE ELECTRICAL DRAWINGSSQUARE FEETSIMILARSEE MECHANICAL DRAWINGSSPECIFICATIONSQUARESEE STRUCTURAL DRAWINGSSTAINLESS STEELSTANDARDSTEELSTORAGESTRUCTURALTREADTO BE DETERMINEDTONGUE AND GROOVETELEPHONETEMPORARYTHICKTOP OFTOP OF SLABTOP OF WALLTYPICALUNDERWRITERS LABORATORYUNLESS OTHERWISE NOTEDUTILITYVARIESVINYL COMPOSITION TILEVERTICALVERIFY IN FIELDVOLUMEWESTWIDE or WIDTHWITHWATER CLOSETWOODWHERE OCCURSWITHOUTWEIGHTYARDBY
L
L
BLOCKPLAN
DRAWING INDEX
PROJECTDATA
2013 CALIFORNIA BUILDING CODE2013 CALIFORNIA ELECTRICAL CODE2013 CALIFORNIA MECHANICAL CODE2013 CALIFORNIA PLUMBING CODE2013 CALIFORNIA FIRE CODE2013 CALIFORNIA ENERGY CODE2013 CALIFORNIA TITLE 24 ENERGY EFFICIENCY STANDARDS2013 CALIFORNIA GREEN BUILDING CODE
2013 SAN FRANCISCO BUILDING CODE AMENDMENTS2013 SAN FRANCISCO ELECTRICAL CODE AMENDMENTS2013 SAN FRANCISCO MECHANICAL CODE AMENDMENTS2013 SAN FRANCISCO PLUMBING CODE AMENDMENTS2013 SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS2013 SAN FRANCISCO HOUSING CODE AMENDMENTS2013 SAN FRANCISCO FIRE CODE AMENDMENTSNFPA 13 & NFPA 13R
EXST.EXT.EXTR.F.F.F.E.F.E.C.F.H.C.FIN.FL.FLUOR.F.O.C.F.O.F.F.O.P.F.O.S.F.R.FT.FURR.FUT.F.V.GA.GALV.G.C.GEN.GWB.GYP.H.B.H.C.H.M.HORIZ.HR.HT.H.W.D.H.W.H.INSUL.INT.JAN.J.C.JT.KIT.LAM.LAV.MAX.M.D.F.MECH.MEMB.MET.MEZZ.MFR.MIN.MISC.M.O.MTD.MTG.MUL.(N)N.N.I.C.NO.NOM.
N.T.S.O.A.O.C.OFF.O.F.S.P.LAMPLYWD.PR.PT.PTN.R.REF.REFR.REQ.R.F.P.RM.R.O.S.S.C.D.SCHED.SECT.S.E.D.S.F.SIM.S.M.D.SPEC.SQ.S.S.D.SST.STD.STL.STOR.STRUCT.T.B.D.T.T>EL.TEMP.THK.T.O.T.O.S.T.O.W.TYP.U.L.U.O.N.UTIL.VAR.V.C.T.VERT.V.I.F.VOL.W.WD.W/W.C.WD.W.O.W/OWT.YD.X or x
1,410 SFEXISTING: 3PROPOSED: 4
EXISTING: 988 SFPROPOSED: 1149 SFRM-1TYPE V-BPROPOSED (N) THROUGHOUT
R-3TWO-UNIT RESIDENTIAL (NOCHANGE)
+ 1866 SF1, 2, 3, ROOF
FRONT: 0'-0"REAR: 24' -6"EAST: 0'-0"WEST : 0'-0"EXISTING: NONEPROPOSED: ENCLOSED ATGROUND LEVEL (2 SPACES)
SYMBOLSPROJECTTEAM
PARTITION TYPE
NORTH ARROW
ELEVATION MARKER
REVISION CLOUD AND REVISION NUMBER.
CENTERLINE
ALIGN(SURFACES, PLANES OR OBJECTS ARE INALIGNMENT)
DETAIL TAG
FINISH TAG
FIXTURE TAG
KEYNOTE
DOOR TAG
EQUIPMENT TAG
WINDOW TAG
CALLOUT / AREA OF DETAIL
DETAIL NUMBER
SHEET NUMBER
DOOR AND HARDWARE TAGDOOR NUMBERHARDWARE NUMBER
ELEVATION - BUILDING
ELEVATION NUMBERELEVATION - INTERIOR
SHEET NUMBER
ROOM TAG
ROOM NAMEROOM NUMBER
SECTION - BUILDINGSECTION NUMBERSHEET NUMBER
OWNER:33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133CONTACT: ANDY AND LISA BAYNE ASTORPHONE: 415.231.2500
ARCHITECT OF RECORD:MARTINKOVIC MILFORD ARCHITECTS101 MONTGOMERY STREET - SUITE 650SAN FRANCISCO, CA 94104CONTACT: BRIAN MILFORDPHONE: 415.346.9990FAX: 415.398.0116
INCLUDED
INCLUDED AND REVISED
LEGEND
08.1
6.16
●
○
NAM
E OF
SET
DATE
DRE
V.
SITE
PER
MIT
SET
ARCH
ITEC
TURA
L
CALLOUT NUMBER
SHEET NUMBER
CALLOUT AREA
BLACK CLOUD INDICATES CURRENTGRAY CLOUD INDICATES PRIOR
FLOOR TAG
STRUCTURAL GRID LINE
SECTION - DETAILSECTION NUMBERSHEET NUMBER
ELEVATION NUMBERSHEET NUMBER
SCOPE OFWORK
APPLICABLECODES
ADDITIONALNOTES
Drawn By:Checked By:
REQUIRED SETBACKS:
PARKING:
SITE INFORMATION:
DEFERRED SUBMITTALS & COORDINATING SCOPE OFWORK AS REQUIRED
LIFE SAFETYLANDSCAPINGSHORING AND/OR UNDERPINNINGFIRE ALARM AND/OR LIFE SAFETYFIRE SPRINKLERCIVIL ENGINEERINGSTRUCTURAL
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
BLOCK/LOT0100 / 021B
DRAWING TITLE
DRAWING NUMBER
DRAWING SERIES
STRUCTURAL ENGINEER:TBD
GENERAL CONTRACTOR:TBD
PROJECT DESIGNER:RIAZ INC.2417 17TH STREETSAN FRANCISCO, CA 94110CONTACT: DIEGO PABONPHONE: 415.657.1775
EXISTING AND PROPOSEDUNIT AREASGROSS SQUARE FOOTAGE BY FLOOR :UNIT 1 EXISTING: 897 SFUNIT 1 PROPOSED: 1317 SFUNIT 2 EXISTING: 900 SFUNIT 2 PROPOSED: 2050 SFEXISTING COMMON AREAS AND COMMON STAIRS: 1011 SFPROPOSED GARAGE, CORRIDORS AND COMMON STAIRS: 895 SFEXISTING YARDS AND DECKS: 282 SFPROPOSED YARDS AND DECKS: 1308 SF
TOTAL EXISTING GROSS BUILDING AREA: 2877 SFTOTAL PROPOSED GROSS BUILDING AREA: 4486 SF55.92% INCREASE IN GROSS SF
UNIT 1 EXISTING BEDROOMS: 2UNIT 1 PROPOSED BEDROOMS: 2UNIT 2 EXISTING BEDROOMS: 2UNIT 2 PROPOSED BEDROOMS: 3
TOTAL EXISTING BEDROOMS: 4TOTAL PROPOSED BEDROOMS: 5
ARCHITECT OF RECORD
PROJECT DESIGNER
08.2
2.17
SITE
PER
MIT
SET
REV
ISIO
N 1
8/23
/201
7 8:
37:2
2 AM
A001
TITLE SHEET
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACE REMODEL & ADDITION
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
A001 TITLE SHEET ● ●C001 BOUNDARY SURVEY ● ○A002A EXISTING SITE PLAN ● ○A002B PROPOSED SITE PLAN ● ●A003 EXISTING CONDITIONS - PHOTOGRAPHS ● ○A004A SECTION 317B CALCULATIONS ●A004B SECTION 317B CALCULATIONS ●A101 FIRST & SECOND FLOOR EXISTING/DEMO PLANS ● ○A102 THIRD FLOOR & ROOF EXISTING/DEMO PLANS ● ○A111 1ST & 2ND FLOOR CONSTRUCTION PLAN ● ●A112 3RD & 4TH FLOOR CONSTRUCTION PLANS ● ○A113 ROOF CONSTRUCTION PLAN ● ●A201 EXTERIOR ELEVATIONS ● ●A202 EXTERIOR ELEVATIONS ● ●A203 EXTERIOR ELEVATIONS ● ●A204 EXTERIOR ELEVATIONS ● ●A301 BUILDING SECTIONS ● ○A901 SCHEDULES ● ●A902 SCHEDULES ● ●
0'SCALE:
4' 8' 16' 32'1/8" = 1'-0"
SCALE: N.T.S.
SEE PLOT PLANBLOCK/LOT: 0100/021B
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
A2041
A201
1
A203 1
A202
1
(E) SLOPED ROOF3 STORIES
DN
DN
DN
DN
DN
(PROPOSED NEWRESIDENCE UNDER PERMIT#
2015.1113.2622 AND2015.1113.2623)
870 UNIION(E) 3 STORY
878-882 UNIION(E) 3 STORY
1926-1930 TAYLOR STREET(E) 4 STORY
1920-1924 TAYLOR STREET(E) 3 STORY
1916-1918 TAYLOR STREET(E) 2 STORY
1914 TAYLOR STREET(E) 4 STORY
ALADDIN TERRACE
TAY
LOR
STR
EE
T
(E) SLOPED ROOF3 STORIES
4.2:
12
34-36 ALADDIN TERRACE(E) 3 STORY
1932 TAYLOR STREET(E) 3 STORY
28-30 ALADDIN TERRACE(E) 4 STORY
22 ALADDIN TERRACE(E) 4 STORY
(E) ADJACENT STAIRS
(E) ADJACENT STAIRS
0.6:
12
38' - 11 1/2"
+/- 56'-0"
3 STORIES+/- 40'-7"
+/- 44'-1"
+/- 43'-0"
+/- 30'-0"
+/- 42'-0"
+/- 25'-0" +/- 32'-0" +/- 33'-6"+/- 24'-6"
+/- 62'-0"
(E) +/- 7'-1 1/2"
LIGHTWELL DEPTH(E) +/- 2'-11"
(E) A
DJAC
ENT
LIGH
T W
ELL
(E) REAR YARD
PROPERTY LINE
PROPERTY LINE
(E) CURB @STREET BELOW
SIDE YARD(E) +/- 4'-2 1/4"
(E) WOOD FENCE
(E) WOODFENCE
(E) WOOD ANDMETAL FENCE
(E) 4
6'-4
1/2
" BUI
LDIN
G DE
PTH
(E) 5
4'-9
" LOT
DEP
TH
LOT WIDTH(E) 25'-9"
ALLE
Y W
IDTH
(E) 1
6'-0
"
SIDE
WAL
K(E
) 3'-0
"
(E) ADJACENT REAR YARD
(E) ADJACENT REAR YARD
(E) ADJACENT REAR YARD
(E) ADJACENT REAR YARD
(E) ADJACENTREAR YARD
(E) STAIR TO ROOF (E) STAIR TO CRAWLSPACE STORAGE
(E) 1
4'-8
3/4
"(E
) +/-
18'-4
1/2
" LIG
HTW
ELL
WID
TH
(E) +/- 1'-2"(E) +/- 9'-10 1/2" (E) +/- 14'-8 3/4"
(E) 1
9'-4
3/4
"(E
) 13'
-8 1
/4"
(E) +
/- 2'
-5"
25%
REA
R YA
RD S
ETBA
CK13
'-8 1
/4"
45%
REA
R YA
RD S
ETBA
CK24
'-6"
SETB
ACK
15'-0
"
37' - 10"
(E) ROOF HATCH
1A301
(E) BAY WINDOW
13' - 6"
36' - 7"
0' - 0"
(E) STAIRAT ROOF
@ FRONT OFBUILDING
(E) S
LOPE
@ REAR OFBUILDING
@ REARYARD
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
37:2
4 AM
A002A
EXISTING SITE PLAN
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
3/16" = 1'-0"1 EXISTING SITE PLAN
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.2016
-
DN
DN
A2042
A202
A203
A201
2
2
2
2A301
25%
REA
R YA
RD S
ETBA
CK13
'-8 1
/4"
45%
REA
R YA
RD S
ETBA
CK24
'-6"
46'-4
1/2
"
870 UNIION(E) 3 STORY
878-882 UNIION(E) 3 STORY
1926-1930 TAYLOR STREET(E) 4 STORY
1920-1924 TAYLOR STREET(E) 3 STORY
1916-1918 TAYLOR STREET(E) 2 STORY
1914 TAYLOR STREET(E) 4 STORY
ALADDIN TERRACE
TAY
LOR
STR
EE
T
34-36 ALADDIN TERRACE(E) 3 STORY
1932 TAYLOR STREET(E) 3 STORY
28-30 ALADDIN TERRACE(E) 4 STORY
22 ALADDIN TERRACE(E) 4 STORY
(E) ADJACENT STAIRS
(E) ADJACENT STAIRS
+/- 56'-0"
+/- 40'-7"
+/- 44'-1"
+/- 43'-0"
+/- 30'-0"
+/- 42'-0"
+/- 25'-0" +/- 32'-0" +/- 33'-6"+/- 24'-6"
+/- 62'-0"
(E) A
DJAC
ENT
LIGH
T W
ELL
(N) DECK @SECOND FLOOR100sf
PROPERTY LINE
PROPERTY LINE
(E) WOOD FENCE
(E) WOOD ANDMETAL FENCE
(E) ADJACENT REAR YARD
(E) ADJACENT REAR YARD
(E) ADJACENT REAR YARD
(E) ADJACENT REAR YARD
(E) ADJACENTREAR YARD
(N) SLIDING SKYLIGHT,ROOF DECK ACCESS
(E) 2
'-5"
(E) 5
4'-9
" LOT
DEP
TH
(E) 25'-9" LOT WIDTH(E) 1'-2" (E) 9'-10 1/2" (E) 14'-8 3/4" AL
LEY
WID
TH(E
) 16'
-0"
SIDE
WAL
K(E
) 3'-0
"
SETB
ACK
15'-0
"
9' - 6 1/4"-0' - 6"
(PROPOSED NEWRESIDENCE UNDER PERMIT#
2015.1113.2622 AND2015.1113.2623)
(E) BAY WINDOW
(E) CURB @STREET BELOW
0' - 0"
(N) LOWEREDREAR YARD @FIRST FLOOR
40' - 0"
(N) ROOF DECK1060sf
(N) METAL GUARDRAIL
(N) METAL GUARDRAIL
40' - 9 1/4"
(N) FLAT ROOF
(N) FLAT ROOF
5'-0
"
5'-0"5'-0"
5'-0
"
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
37:2
4 AM
A002B
PROPOSED SITE PLAN
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
3/16" = 1'-0"1 (N) SITE PLAN
1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
1926-1930 TAYLOR STREETSUBJECT PROPERTY
34-36 ALADDIN TERRACE1932-1938 TAYLOR STREET
15 ALADDIN TERRACE 878-882 UNION STREET870 UNION STREETSUBJECT PROPERTY
SUBJECT PROPERTY878-882 UNION STREET SUBJECT PROPERTY
SUBJECT PROPERTY870 UNION STREET
15 ALADDIN TERRACE SUBJECT PROPERTY
34-36 ALADDIN TERRACE1932-1938 TAYLOR STREET 28-30 ALADDIN TERRACE 34-36 ALADDIN TERRACE 28-30 ALADDIN TERRACE
1920-1924 TAYLOR STREET 1926-1930 TAYLOR STREET1916-1918 TAYLOR STREET
1914 TAYLOR STREET
SUBJECT PROPERTY
(PROPOSED NEWRESIDENCE UNDER PERMIT#
2015.1113.2622 AND2015.1113.2623)
870 UNIION(E) 3 STORY
878-882 UNIION(E) 3 STORY
1926-1930 TAYLOR STREET(E) 4 STORY
1920-1924 TAYLOR STREET(E) 3 STORY
1916-1918 TAYLOR STREET(E) 2 STORY
1914 TAYLOR STREET(E) 4 STORY
ALADDIN TERRACE
TAY
LOR
STR
EE
T
34-36 ALADDIN TERRACE(E) 3 STORY
1932 TAYLOR STREET(E) 3 STORY
28-30 ALADDIN TERRACE(E) 4 STORY
22 ALADDIN TERRACE(E) 4 STORY
+/- 56'-0"
3 STORIES+/- 40'-7"
+/- 44'-1"
+/- 43'-0"
+/- 30'-0"
+/- 42'-0"
+/- 25'-0" +/- 32'-0"+/- 33'-6"
+/- 24'-6"
+/- 62'-0"
33-35 ALADDIN TERRACESUBJECT PROPERTY
(E) 3 STORIES+/- 38'-11"
132
45
6
7
8
9
10
11
12
13
1932 TAYLOR STREET 1926-1930 TAYLOR STREETSUBJECT PROPERTY34-36 ALADDIN TERRACE
28-30 ALADDIN TERRACE
1920-1924 TAYLOR STREET
1926-1930 TAYLOR STREET
1916-1918 TAYLOR ST.1926-1930 TAYLOR STREET
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:1
0 AM
A003
EXISTING CONDITIONS -PHOTOGRAPHS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
2 SOUTH SIDE OF ALADDIN TERRACE6 NORTH SIDE OF ALADDIN TERRACE
12 VIEWS FROM SUBJECT PROPERTY ROOF
7 REAR OF SUBJECT BUILDING8 ADJACENT BUILDING TO SOUTH
3 FRONT OF SUBJECT BUILDING 1 SOUTH SIDE OF ALADDIN TER.5 Existing Photos - north 2 4 Existing Photos - north 3
11 Existing Photos - from roof 2
1/8" = 1'-0"EXISTING SITE PLAN
13 ALADDIN TERRACE FROM TAYLOR ST
9 ADJACENT BUILDING TO WEST10 ADJACENT BUILDING TO WEST
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.2016
-
(E) STORAGE
(E) OFFICE
(E) MECHANICAL
(E) ADJACENT PROPERTY
(E) REAR YARD
(E) SIDE YARD
UP
UP
UP
DN
UP
PROPERTY LINE
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(E) T.O.CURB0' - 0"
(E) REAR T.O.ROOF36' - 7 7/8"
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(N) FOURTH FLOOR29' - 2 1/2"
(E) T.O.CURB0' - 0"
(E) REAR T.O.ROOF36' - 7 7/8"
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(E) T.O.CURB0' - 0"
(E) REAR T.O.ROOF36' - 7 7/8"
(E) KITCHEN(E) DINING ROOM
(E) LIVING ROOM
(E) BATH
(E) BEDROOM
(E) BEDROOM
UP
DN
DN
UPDN
(E) ADJACENT PROPERTY
PROPERTY LINE
(E) LIVING/DINING
(E) KITCHEN
(E) BATH
(E) BEDROOM
(E) CLOSET
(E) CLOSET
(E) BEDROOM
DN
UP
DN
(E) ADJACENT PROPERTY
PROPERTY LINE
(E) SLOPED ROOF
(E) ADJACENT PROPERTY
DNDN
PROPERTY LINE
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(N) FOURTH FLOOR29' - 2 1/2"
(N) THIRD FLOOR19' - 1"
(N) SECOND FLOOR9' - 6 1/4"
(E) REAR T.O.ROOF36' - 7 7/8"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(E) REAR T.O.ROOF36' - 7 7/8"
SECTION 317(b) DEMOLITION CALCULATIONS - METHOD 2
ABOVE GRADE VERTICAL ELEMENTS IN SQUAREFEET
EXISTING PROPOSEDREMOVAL
PERCENTREMOVAL
PERCENT BYCODE
COMPLIES?
FRONT (NORTH) ELEVATION
REAR (SOUTH) ELEVATION
WEST ELEVATION
EAST ELEVATION
TOTAL:
966.8 SF
482.9 SF
1668.8 SF
1389.5 SF
4508 SF
364.8 SF
321.8 SF
742.8 SF
587.5 SF
2016.9
37.7%
66.6 %
44.5 %
42.3 %
44.7% 50% YES
ABOVE GRADE HORIZONTAL ELEMENTS IN SQUAREFEET
EXISTING PROPOSEDREMOVAL
PERCENTREMOVAL
PERCENT BYCODE
COMPLIES?
FIRST FLOOR (SLAB ON GRADE)
SECOND FLOOR
THIRD FLOOR
ROOF
TOTAL: 2890 SF 2890 SF 100% 50% NO
N/A
947 SF
941 SF
1002 SF
N/A
947 SF
941 SF
1002 SF
N/A
100%
100%
100%
-SURFACE AREA TO BE REMOVED
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:2
4 AM
A004A
SECTION 317BCALCULATIONS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AuthorApprover
1/8" = 1'-0"1 HORIZONTAL DEMOLITION CALCULATION DIAGRAMS
1/8" = 1'-0"2 VERTICAL DEMOLITION CALCULATION DIAGRAMSEXISTING SIDE ELEVATION (EAST)EXISTING REAR ELEVATION (NORTH) EXISTING SIDE ELEVATION (WEST)
SECOND FLOOR EXISTING/DEMOLITION PLAN THIRD FLOOR EXISTING/DEMOLITION PLAN ROOF EXISTING/DEMOLITION PLANFIRST FLOOR EXISTING/DEMOLITION PLAN (SLAB ON GRADE)
EXISTING FRONT ELEVATION (SOUTH)
1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
(E) STORAGE
(E) OFFICE(E) MECHANICAL
(E) REAR YARD
(E) SIDE YARD
UP
UP
UP
2'-1 1/2" 8'-0" 0'-6 1/2" 5'-6" 0'-7"
21'-6 3/4"
PROPERTY LINE
1'-0" 8'-0"
(E) STORAGE
(E) OFFICE(E) MECHANICAL
(E) REAR YARD
(E) SIDE YARD
UP
UP
UP
6'-3
1/2
"
2'-11 1/4"
16'-1
0 3/
4"
2'-1 1/2"
26'-9
3/4
"7'-1 1/2"
12'-8
"
21'-6 3/4"
2'-11"
3'-3 1/4
"
14'-8
3/4
"
8'-0" 0'-6 1/2" 5'-6" 0'-7"
PROPERTY LINE
1'-0" 8'-0"
SECTION 317(b) DEMOLITION CALCULATIONS - METHOD 1
SUM OF FRONT AND REAR WALLS MEASUREDIN LINEAL FEET AT THE FOUNDATION
EXISTING PROPOSEDREMOVAL
PERCENTREMOVAL
PERCENT BYCODE
COMPLIES?
FRONT (NORTH) ELEVATION
REAR (SOUTH) ELEVATION
TOTAL:
25'-7"
21'-6 3/4"
46'-1 3/4"
21'-6"
0'-0"
21'-6"
86%
0%
46.6% 50% YES
SUM OF EXTERIOR WALLS MEASURED INLINEAL FEET AT THE FOUNDATION
EXISTING PROPOSEDREMOVAL
PERCENTREMOVAL
PERCENT BYCODE
COMPLIES?
PERIMETER 65% YES150'-1/2" 73'-7 1/4" 49.1%
-SURFACE AREA TO BE REMOVED
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:2
6 AM
A004B
SECTION 317BCALCULATIONS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AuthorApprover
3/16" = 1'-0"1 FRONT & REAR WALL DIAGRAM 3/16" = 1'-0"2 PERIMETER WALL DIAGRAM
1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
HB
G
PLAN LEGEND
X1
(E) CONSTRUCTION TO BE REMOVED
(N) NON-RATED PTN
(N) 1HR-RATED, INSULATED INT. PTN.
DASHED LINE INDICATES ADDITIONALBACKING TO BE MOUNTED. SEE 1/A111FOR LOCATIONS. PROVIDE BACKING FORMILLWORK A.R. ALL BACKING TO BECONCEALED
AREA NOT IN CONTRACT.
(N) 2HR-RATED, INSULATED INT. PTN.
(N) NON-RATED ACOUSTIC INT PTN.
(N) SWING DOOR
WALL TAG
(E) PTN TO REMAIN
01GP01
(N) DOOR TAG
(E) CONSTRUCTION TO BE REMOVED
(N) INT. TEMPERED GLASS PTN.
ITEMS OVERHEAD
HOSE BIB
GAS SHUTOFF VALVE
A2041
A201
1
A203 1
A202
1
(E) SHAREDSTORAGE
(E) SHAREDOFFICE
(E) SHAREDMECHANICAL
(E) ADJACENT PROPERTY
(E) ADJACENTPROPERTY
EXTEIOR STAIR
PROPOSEDLIGHTWELL
ATADJACENTPROPERTY
(E) +
/- 18
'-4 1
/2" L
IGHT
WEL
L(E
) +/-
14'-8
3/4
"
(E) REAR YARD
ALADDIN TERRACE1
A301
(E) +
/- 8'
-4 3
/4"
(E) SIDE YARD
(E) +/- 7'-1 1/2"
(E) +/- 4'-2 1/4"
(E) +
/- 26
'-9 3
/4"
UP
UP
UP
DN
UP
(E)LIGHTWELL
D12
D1
D2D5
D5
D12
D7
D2
D2
D2
D2
D2
D5
D5
D10
D3 D3
D9
D3
D1
D1
D1
D1
D12
D9
D9D9
D7
D7
D4
D4
D5
D11D11
D1
D8
D8
D8
D8
D8
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPERTY LINE
2'-11"
A2041
A201
1
A203 1
A202
1
(E) KITCHEN(E) DINING ROOM
(E) LIVING ROOM
(E) BATH
(E) BEDROOM
(E) BEDROOM
1A301
UP
DN
DN
UPDN
(E) ADJACENT PROPERTY
(E) ADJACENTPROPERTY
EXTEIOR STAIR
(E) +
/- 8'
-4 3
/4"
(E) +
/- 46
'-4 1
/2" B
UILD
ING
DEPT
H
(E) +
/- 18
'-4 1
/2" L
IGHT
WEL
L
(E) +
/- 26
'-9 3
/4"
(E) +/- 7'-1 1/2"
(E) +/- 4'-2 1/4"
PROPOSEDLIGHTWELL
ATADJACENTPROPERTY
(E)LIGHTWELL
REAR
BAY
(E) +
/- 0'
-11
3/4"
(E) +
/- 2'
-5"
(E) +/- 1'-2"(E) +/- 9'-10 1/2"
D3
D3
D3
D3
D3
D3
D3
D3
D3 D3
D3
D2
D2D2
D2
D2
D2
D2
D5
D5
D5
D5
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D14
D13
D6
D13
D3
D1
D1
D1D1
D19
D8
D8
D8
D8
D8
D8
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPERTY LINE
2'-11"
(E) UNIT 1897 SF
D6
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:2
8 AM
A101
FIRST & SECOND FLOOREXISTING/DEMO PLANS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
KEYNOTESDEMOLITION
D1 REMOVE (E) WALL TO ACCOMMODATE (N) WORKD2 REMOVE (E) DOORD3 REMOVE (E) WINDOW TO ACCOMMODATE (N) WORKD4 REMOVE (E) PLUMBING FIXTURE; CAP OFF/RE-ROUTE UTILITY
LINES AS REQ'DD5 REMOVE (E) STAIRS AND (E) HANDRAIL W.O.D6 REMOVE PORTION OF (E) FLOOR PLATE TO ACCOMMODATE (N)
WORK - SEE NEW CONSTRUCTION SHEETS A111-A113D7 REMOVE (E) COLUMNSD8 REMOVE (E) WALL FINISHES. (E) FRAMING TO REMAIND9 REMOVE (E) FLOOR SLAB AND EXCAVATE AS REQUIRED FOR (N)
FIRST FLOOR SLABD10 RELOCATE (E) RADIANT HEAT MANIFOLD AND TANKLESS WATER
HEATERD11 (E) REAR YARD TO BE EXCAVATED TO ACCOMMODATE (N) WORKD12 REMOVE (E) FOUNDATION WALLD13 (E) FLOOR ASSEMBLY TO BE RAISED, SEE (E) AND (N) LEVELS ON
ELEVATION SHEETS A201-A204D14 REMOVE (E) REAR POPOUTD19 REMOVE (E) WALL VENT
GENERAL NOTESDEMOLITION PLAN
1 SEE SHEET A001 FOR LEGEND AND ABBREVIATIONS2 CONTRACTOR SHALL COORDINATE THE EXTENT OF THE
DEMOLITION WITH NEW CONSTRUCTION. REFER TO PLANS ANDELEVATIONS. PROTECT ALL PORTIONS OF (E) STRUCTURE TOREMAIN.
3 REMOVE ALL (E) FINISHES, HARDWARE, EQUIPMENT, CONDUIT,PLUMBING, AND FRAMING NECESSARY TO ACCOMMODATE ALLNEW WORK.
4 CAP OFF ALL PLUMBING, GAS, & ELECTRICAL LINES WHEREAPPLIANCES AND FIXTURES ARE DISCONNECTED.
5 CONTRACTOR SHALL ENSURE THE STABILITY OF ALL (E)STRUCTURE, FRAMING AND FOUNDATIONS TO REMAIN DURINGDEMOLITION AND CONSTRUCTION OF NEW WORK
6 CONTRACTOR SHALL REPLACE ALL DAMAGED OR DECAYEDEXISTING WOOD FRAMING, FLOOR, OR SHEATHING IN AREAS OFREMODEL AND REPAIR. NOTIFY ARCHITECT IF DAMAGED ORDECAYED CONDITIONS ARE ENCOUNTERED PRIOR TOCOMMENCING REPAIR WORK.
7 DOCUMENTATION HEREIN DOES NOT AUTHORIZE, DESCRIBE,REQUIRE OR INCLUDE THE REMOVAL OF ANY HAZARDOUSMATERIALS OR ELEMENTS, INCLUDING, BUT NOT LIMITED TOLEAD PAINT, ASBESTOS AND PCB'S. GENERAL CONTRACTORSHALL COMPLY WITH ALL APPLICABLE LAWS, REGULATIONS,ORDINANCES AND RULES RELATING TO ANY HAZARDOUS ORTOXIC MATERIALS. IF GENERAL CONTRACTOR DISCOVERS ANYSUCH MATERIALS ON THE PROPERTY, GENERAL CONTRACTORSHALL PROMPTLY NOTIFY THE OWNER. ANY REMOVAL OFHAZARDOUS MATERIALS SHALL BE DOCUMENTED SEPARATELY,AND SHALL OCCUR AS REQUIRED BY CODE AND REGULATORYREQUIREMENTS.
1/4" = 1'-0"1 FIRST FLOOR EXISTING/DEMOLITION PLAN 1/4" = 1'-0"2 SECOND FLOOR EXISTING/DEMOLITION PLAN
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.2016
-
HB
G
PLAN LEGEND
X1
(E) CONSTRUCTION TO BE REMOVED
(N) NON-RATED PTN
(N) 1HR-RATED, INSULATED INT. PTN.
DASHED LINE INDICATES ADDITIONALBACKING TO BE MOUNTED. SEE 1/A111FOR LOCATIONS. PROVIDE BACKING FORMILLWORK A.R. ALL BACKING TO BECONCEALED
AREA NOT IN CONTRACT.
(N) 2HR-RATED, INSULATED INT. PTN.
(N) NON-RATED ACOUSTIC INT PTN.
(N) SWING DOOR
WALL TAG
(E) PTN TO REMAIN
01GP01
(N) DOOR TAG
(E) CONSTRUCTION TO BE REMOVED
(N) INT. TEMPERED GLASS PTN.
ITEMS OVERHEAD
HOSE BIB
GAS SHUTOFF VALVE
A2041
A201
1
A203 1
A202
1
(E) LIVING/DINING
(E) KITCHEN
(E) BATH
(E) BEDROOM
(E) CLOSET
(E) CLOSET
(E) BEDROOM
DN
UP
DN
(E) ADJACENT PROPERTY
(E) ADJACENTPROPERTY
EXTEIOR STAIR
(E) +/- 4'-2 1/4"
(E) +/- 7'-1 1/2"
(E) +
/- 8'
-4 3
/4"
(E) +
/- 46
'-4 1
/2" B
UILD
ING
DEPT
H
(E) +
/- 2'
-5"
(E) +
/- 26
'-9 3
/4"
(E) +/- 1'-2"(E) +/- 9'-10 1/2"
(E) +
/- 18
'-4 1
/2"
(E) +
/- 14
'-8 3
/4"
REAR
BAY
(E) +
/- 0'
-11
3/4"
1A301
D5
D14D3
D2
D3D3
D2 D1
D1D1
D3
D3
D1
D2
D6
D6
D2
D5
D1
D2
D1D1
D2
D3 D1
D3
D3
D3D1
D1
D20
D3
D3
D1
D1D1
D3
D3
D6D6
D3
D1
D19
D1
D2
D1
D8
D8
D8
D8
D8
D8
D8
PROPOSEDLIGHTWELL
ATADJACENTPROPERTY
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPERTY LINE
(E)LIGHTWELL
2'-11"
D6
(E) UNIT 2900 SF
A2041
A201
1
A203 1
A202
1
(E) SLOPED ROOF
(E) +
/- 0.
6:12
(E) +
/- 4.
2:12
(E) +/- 4'-2 1/4"
(E) +/- 7'-1 1/2"
(E) +
/- 8'
-4 3
/4"
(E) +
/- 46
'-4 1
/2" B
UILD
ING
DEPT
H
(E) +
/- 18
'-4 1
/2"
(E) +
/- 14
'-8 3
/4"
(E) ADJACENT PROPERTY
(E) ADJACENTPROPERTY
EXTEIOR STAIR
DN
DN
1A301
D6
D17D17
D21
D5
D5
D17
D14
D1
D1
D1D1
D1
D1D1
PROPOSEDLIGHTWELL
ATADJACENTPROPERTY
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPERTY LINE
(E) +
/- 2'
-5"
(E) +
/- 26
'-4"
(E) +/- 1'-2"(E) +/- 9'-10 1/2"
2'-11"
(E)LIGHTWELL
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:3
1 AM
A102
THIRD FLOOR & ROOFEXISTING/DEMO PLANS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
KEYNOTESDEMOLITION
D1 REMOVE (E) WALL TO ACCOMMODATE (N) WORKD2 REMOVE (E) DOORD3 REMOVE (E) WINDOW TO ACCOMMODATE (N) WORKD5 REMOVE (E) STAIRS AND (E) HANDRAIL W.O.D6 REMOVE PORTION OF (E) FLOOR PLATE TO ACCOMMODATE (N)
WORK - SEE NEW CONSTRUCTION SHEETS A111-A113D8 REMOVE (E) WALL FINISHES. (E) FRAMING TO REMAIND14 REMOVE (E) REAR POPOUTD17 REMOVE (E) ROOF TO ACCOMMODATE (N) WORKD19 REMOVE (E) WALL VENTD20 REMOVE (E) FIREPLACE AND SURROUNDD21 REMOVE (E) ROOF ACCESS HATCH
GENERAL NOTESDEMOLITION PLAN
1 SEE SHEET A001 FOR LEGEND AND ABBREVIATIONS2 CONTRACTOR SHALL COORDINATE THE EXTENT OF THE
DEMOLITION WITH NEW CONSTRUCTION. REFER TO PLANS ANDELEVATIONS. PROTECT ALL PORTIONS OF (E) STRUCTURE TOREMAIN.
3 REMOVE ALL (E) FINISHES, HARDWARE, EQUIPMENT, CONDUIT,PLUMBING, AND FRAMING NECESSARY TO ACCOMMODATE ALLNEW WORK.
4 CAP OFF ALL PLUMBING, GAS, & ELECTRICAL LINES WHEREAPPLIANCES AND FIXTURES ARE DISCONNECTED.
5 CONTRACTOR SHALL ENSURE THE STABILITY OF ALL (E)STRUCTURE, FRAMING AND FOUNDATIONS TO REMAIN DURINGDEMOLITION AND CONSTRUCTION OF NEW WORK
6 CONTRACTOR SHALL REPLACE ALL DAMAGED OR DECAYEDEXISTING WOOD FRAMING, FLOOR, OR SHEATHING IN AREAS OFREMODEL AND REPAIR. NOTIFY ARCHITECT IF DAMAGED ORDECAYED CONDITIONS ARE ENCOUNTERED PRIOR TOCOMMENCING REPAIR WORK.
7 DOCUMENTATION HEREIN DOES NOT AUTHORIZE, DESCRIBE,REQUIRE OR INCLUDE THE REMOVAL OF ANY HAZARDOUSMATERIALS OR ELEMENTS, INCLUDING, BUT NOT LIMITED TOLEAD PAINT, ASBESTOS AND PCB'S. GENERAL CONTRACTORSHALL COMPLY WITH ALL APPLICABLE LAWS, REGULATIONS,ORDINANCES AND RULES RELATING TO ANY HAZARDOUS ORTOXIC MATERIALS. IF GENERAL CONTRACTOR DISCOVERS ANYSUCH MATERIALS ON THE PROPERTY, GENERAL CONTRACTORSHALL PROMPTLY NOTIFY THE OWNER. ANY REMOVAL OFHAZARDOUS MATERIALS SHALL BE DOCUMENTED SEPARATELY,AND SHALL OCCUR AS REQUIRED BY CODE AND REGULATORYREQUIREMENTS.
1/4" = 1'-0"1 THIRD FLOOR EXISTING/DEMOLITION PLAN 1/4" = 1'-0"2 ROOF EXISTING/DEMOLITION PLAN
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.2016
-
UP
UP
UP
DN
DN
UP
DN
G
G
HB
G
A2042
A202
A203
A201
2
2
2
ALADDIN TERRACE
(N) GARAGE
(N) COMMONENTRY
ELEVATOR
(N) ELEVATORVESTIBULE
(N) MASTERBEDROOM
(N) MASTERBATHROOM
MASTER CLOSET
MASTER CLOSET
(N) LOWERED REARYARD
CLOSET
MAI
L
2A301
(E) 25'-9" LOT WIDTH
(E) 5
4'-9
" LOT
DEP
TH
3'-0
"
3'-1
3/4
"
2 TR
EADS
@ 1
0" M
IN3
RISE
RS @
7 1
/8" M
AX
3'-0
"
8'-3
"
3'-4 1/2" 4'-4"
1
3
5
10
9
7
4
2
11
1
6
(E) UNIT 11317sf TOTAL
3'-0 1/4"
3'-0"
(N) EXIT PASSAGE
(E) +
/- 8'
-4 3
/4"
3'-0
"
6 TREADS @ 10" MIN7 RISERS @ 7 1/4" MAX
830
" MIN
C15
C7
C15
C8
C17C17
C15 C20
C2
C2
C10
C2C2
C5
C11
C21
C22
18'-0
"
18'-0
"
8'-0" 8'-0"
PROPERTY LINE
9 RI
SERS
@ 7
1/4
" MAX
8 TR
EADS
@ 1
0" M
IN
C27
C9
C28
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPOSEDLIGHTWELL
ATADJACENTPROPERTY
STAIR ALCOVE
C21
37
A2042
A202
A203
A201
2
2
2
3'-5 1/2"
100 SF
(N) PRIVATE REARDECK
(N) BEDROOM
(N) KITCHEN
(N) BATH
CLOSET
LIVING ROOM
DINING ROOM
(N) ELEVATOR
DESK
W/D
REF
DW
12 TREADS @ 10" MIN13 RISERS @ 7 1/4" MAX 3'-0"
2'-1"
3'-0"
4'-4"
(E) UNIT 11317sf TOTAL
2A301
16 6
15
14
13
12
17
(E) 25'-9" LOT WIDTH
(E) 5
4'-9
" LOT
DEP
TH
(E) +
/- 8'
-4 3
/4"
7 TR
EADS
@ 1
0" E
A8
RISE
RS @
7 1
/4" E
A3'
-0"
3'-0"8 TREADS @ 10" MIN
9 RISERS @ 7 1/4" MAX
3'-0
"
3'-0" MIN
C1
C1
C5
C5
C6
C14
C2
C5
C1
C19
C8
C8
C15
C15
C15C8
C7
C8
C7
C14
C4C13
C3
PROPERTY LINE
4 3 2
5C11C11
(N) LOWERED REARYARD BELOW
(N) MECH.CHASE
C29
UNIT 1
C29
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPOSEDLIGHTWELL
ATADJACENTPROPERTYCOMMON STAIR
C2C2
PLAN LEGEND
X1
(E) CONSTRUCTION TO BE REMOVED
(N) NON-RATED PTN
(N) 1HR-RATED, INSULATED INT. PTN.
DASHED LINE INDICATES ADDITIONALBACKING TO BE MOUNTED. SEE 1/A111FOR LOCATIONS. PROVIDE BACKING FORMILLWORK A.R. ALL BACKING TO BECONCEALED
AREA NOT IN CONTRACT.
(N) 2HR-RATED, INSULATED INT. PTN.
(N) NON-RATED ACOUSTIC INT PTN.
(N) SWING DOOR
WALL TAG
(E) PTN TO REMAIN
01GP01
(N) DOOR TAG
(E) CONSTRUCTION TO BE REMOVED
(N) INT. TEMPERED GLASS PTN.
ITEMS OVERHEAD
HOSE BIB
GAS SHUTOFF VALVE
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:3
6 AM
A111
1ST & 2ND FLOORCONSTRUCTION PLAN
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
KEYNOTESCONSTRUCTION
C1 (N) APPLIANCES AND EQUIPMENTC2 (N) PLUMBING FIXTURES, TYP.C3 (N) BUILT-IN CASEWORKC4 (N) FULL HEIGHT BUILT-IN CASEWORKC5 (N) BASE CABINETS AND COUNTERSC6 (N) UPPER CABINETSC7 (N) GRIPPABLE HANDRAIL @ 36" ABOVE NOSING; DESIGN SHALL
RESIST LINEAR LOAD OF 50 PLF IN ACCORDANCE W/ SECTION 4.5.1OF ASCE 7 PER CBC 1607.8.1
C8 (N) GUARDRAIL @ 42" W/ 4" MAX OPENING; DESIGN SHALL RESISTLINEAR LOAD OF 50 PLF IN ACCORDANCE W/ SECTION 4.5.1 OFASCE 7 PER CBC 1607.8.1
C9 MINIMUM 200 SQ. INCH LOUVER FOR GARAGE VENTILATIONC10 (N) TEMPERED GLASS SHOWER ENCLOSUREC11 (N) WINDOW TO BE OPERABLE AND COMPLY W/ EGRESS
REQUIREMENTS PER CBC 1029C13 (N) WASHER/DRYER AND HOOK UPS. VENT DRYER TO EXTERIORC14 (N) GAS SHUTOFFC15 (N) CARPENTER-BUILT STAIR; (3) 2X12 WOOD STRINGERS MIN 2/
3/4" PLYWOOD TREADS & RISERS; P.T. LUMBER AT ALL EXTERIORCONDITIONS
C17 WALLS AND CEILING OF PASSAGE SHALL BE RATED ANDCONSTRUCTED PER CBC 707 & 711 (CBC TABLE 721.1(3) 13-1.4)
C19 (N) EXHAUST HOOD COMPLIANT WITH CBC 2013, EXTERIOR VENTC20 (N) PASSENGER ELEVATORC21 PROVIDE 5/8" GYPSUM BOARD ON UNDERSIDE OF STAIRSC22 (N) DECK ABOVEC27 (N) DEDICATED VERTICAL BICYCLE RACKS PER SF ZONING
ADMINISTRATOR BULLETIN NO. 9C28 LOCATION OF EQUAL ACCESS FOR STORAE, COLLECTION AND
LOADING OF RECYCLABLE, COMPOSTABLE AND LAND FILLMATERIALS
C29 (N) PAINTED WOOD GUARDRAIL
1/4" = 1'-0"1 FIRST FLOOR CONSTRUCTION PLAN 1/4" = 1'-0"2 SECOND FLOOR CONSTRUCTION PLAN
GENERAL NOTESCONSTRUCTION PLAN (RES)
SEE SHEET A004 FOR ACCESSIBLE CLEARANCES & FURTHERINFORMATION ON RECEPTION DESKSEE GENERAL NOTES ON SHEET A002.
1 ALL (N) WALLS TYPE "A" U.O.N. SEE SCHEDULE, A901.2 ALL DIMENSIONS ARE TO FACE OF FINISH, CENTERLINE OF
OPENING OR EDGE OF JAMB FRAME, U.O.N.3 CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING.ARCHITECT TO REVIEW ALL CHALK LINES IN FIELD PRIOR TOSTUD INSTALLATION.
4 DOORS NOT LOCATED BY DIMENSION SHALL BE PLACED 3" OFFJAMB, U.O.N. REFER TO DOOR SCHEDULE FOR TYPES AND SIZESON SHEET A901.
5 PROVIDE & INSTALL FLASHING, COUNTERFLASHING, CAPFLASHING, METAL TRIM, OTHER FABRICATED ITEMS ANDMISCELLANEOUS SHEET METALWORK AT JUNCTIONS OF A ROOFAND WALL, AT CHIMNEYS, OVER EXPOSED DOORS ANDWINDOWS, AT CHANGES OF SIDING MATERIAL IN ROOF VALLEYSOR WHERE REQUIRED TO PROVIDE COMPLETE WATERTIGHT ANDWATERPROOF CONSTRUCTION.
6 PROVIDE & INSTALL ONE PIECE GSM PAN FLASHING AT ALL NEWAND REPLACEMENT EXTERIOR DOORS. COMPLY WITH ASTME2112-07, STANDARD PRACTICE FOR INSTALLATION OF EXTERIORWINDOWS, DOORS, AND SKYLIGHTS.
7 WATERPROOFING SHALL OVERLAP FLASHINGS FOR POSITIVEDRAINAGE AT ALL CONDITIONS.
8 FLASHING & SHEET METALWORK SHALL BE FABRICATED ANDINSTALLED IN ACCORDANCE WITH SHEET METAL & AIRCONDITIONING CONTRACTORS' NATIONAL ASSOCIATION(SMACNA) ARCHITECTURAL SHEET METAL MANUAL. COMPLYWITH MINIMUM THICKNESS OR GAGE REQUIREMENTS ASSPECIFIED IN SMACNA ARCHITECTURAL SHEET METAL MANUAL
9 ISOLATE AND PROTECT DISSIMILAR METALS FROM CONTACTWITH EACH OTHER BY APPLYING SPECIFIED ISOLATIONMATERIAL TO CONTACT SURFACES. PROTECT SURFACES OFSHEET METAL IN CONTACT WITH CONCRETE, TREATED WOOD, ORALUMINUM WITH A HEAVY COATING OF BITUMINOUS PAINT ASRECOMMENDED BY MANUFACTURER/FABRICATOR.
10 FLASHING & SHEET METALWORK WILL NOT BE MEASUREDSEPARATELY FOR PAYMENT BUT WILL BE PAID FOR AS PART OFTHE CONTRACT LUMP SUM PRICE FOR ARCHITECTURAL WORK.
11 PROVIDE MINIMUM OF R-19 BATT INSULATION IN EXTERIORWALLS ADJACENT TO LIVING SPACE.
12 PROVIDE CEMENT BOARD BACKING IN AREAS TO RECEIVE TILEFINISH.
13 WOOD LOCATED NEARER THAN 6" TO EARTH SHALL BE TREATEDWOOD.
14 ALL DOORS AND WINDOWS NOT TAGGED ARE EXISTING TOREMAIN U.O.N.
15 ALL TOILETS TO HAVE A MINIMUM CLEARANCE OF 24" IN FRONTAND 15" FROM CENTERLINE OF THE TOILET TO EACH SIDE.
16 STAIRWAYS SHALL HAVE A MINIMUM HEADROOM CLEARANCEOF 80 INCHES ABOVE THE FRONT EDGE OF THE NOSING.
17 ALL APPLIANCES WITH QUICK-ACTING VALVES, INCLUDING BUTNOT LIMITED TO DISHWASHERS & CLOTHES WASHERS, SHALLHAVE WATER HAMMER ARRESTORS (CPC 609.10).
18 ALL EXISTING NON-COMPLIANT AND NEW PLUMBING FIXTURESSHALL COMPLY WITH CALIFORNIA SB-407 (2009).
19 WATER HEATERS SHALL HAVE SEISMIC STRAPPING AT A POINTWITHIN THE UPPER 1/3 AND THE LOWER 1/3 OF THE WATERHEATER’S VERTICAL DIMENSIONS. AT THE LOWER POINT, AMINIMUM DISTANCE OF FOUR (4) INCHES SHALL BE MAINTAINEDABOVE THE CONTROLS TO THE STRAP. (CPC 507.2).
20 KITCHEN RANGES SHALL BE PROVIDED WITH A METALVENTILATING HOOD. A VERTICAL CLEARANCE OF 24" MINIMUMBETWEEN THE COOKTOP & METAL VENTILATING HOOD SHALLBE MAINTAINED. THE HOOD SHALL BE AS WIDE AS THE RANGEAND CENTERED OVER THE UNIT. THE METAL HOOD SHALL BE0.0122" MINIMUM THICK (2013 CMC 920.3).
21 KITCHEN IS REQUIRED TO HAVE AN EXHAUST FAN DUCTED TOTHE OUTSIDE WITH A MINIMUM VENTILATION RATE OF 100 CFM.
22 ALL EXHAUST FAN DUCTING, INCLUDING BUT NOT LIMITED TO TOKITCHEN AND BATHROOM EXHAUST FANS, SHALL BE SIZEDACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1.
23 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL BEACCESSIBLE THROUGH AN OPENING AND PASSAGEWAY ATLEAST AS LARGE AS THE LARGEST COMPONENT OF THEAPPLIANCE, AND NOT LESS THAN 22 INCHES BY 30 INCHES. (CPC508.4).
24 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL HAVEA SOLID FLOOR PASSAGEWAY OF NOT LESS THAN 24 INCHESAND A WORK PLATFORM OF NOT LESS THAN 30 INCHES BY 30INCHES IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CPC508.4.2 & 508.4.3).
25 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL HAVEA PERMANENT 120-VOLT RECEPTACLE OUTLET AND A LIGHTINGFIXTURE NEAR THE APPLIANCE. (CPC 508.4.4).
26 ALL GLASS SHALL BE BIRD SAFE GLAZING PER SAN FRANCISCOSTANDARDS FOR BIRD SAFE BUILDINGS.
1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
UP
DN
DN
UP
GG
HB
G
A2042
A202
A203
A201
2
2
2
(N) BEDROOM
(N) BEDROOM
(N) BATH
MASTERBATHROOM
(N) MASTERBEDROOM
MASTER CLOSET
MASTER CLOSET
CLOSET
ELEV
(E) UNIT 22050sf TOTAL
CLOSET
CLOS
ET
2A301
3'-8" 18
19
20
22
23
24
25
26
27
28
29
11 13
21
3'-7
1/4
"
(N) HALLWAY
(E) 25'-9" LOT WIDTH
(E) 5
4'-9
" LOT
DEP
TH
(E) +
/- 8'
-4 3
/4"
3'-0"
7 TREADS @ 10" MIN8 RISERS @ 7 1/4" MAX
30" M
IN
3'-0
"
3'-0"
7 TR
EADS
@ 1
0" M
IN8
RISE
RS @
7 1
/4" M
AX
BAY WIDTH(E) +/- 9'-4 3/4"
BAY
DEPT
H(E
) +/-
2'-5
"
C10
C2
C2
C5
C2
C23
C23
C20
C8
C7C15
C2C2C4
C5
C2
C3
C7
C8C15
C24
PROPERTY LINE
C29
9
8 7
1210
C11
C11
C21C21
C11
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPOSEDLIGHTWELL
ATADJACENTPROPERTY
C2
A2042
A202
A203
A201
2
2
2
(N) BATH
(N) LAUNDRY
ELEV
PANTRY
CLOS
ET
(N) FLEX ROOM
(N) KITCHEN
(N) LIVING/ DINING
MURPHY BED
DESK
T.C.
REF
DW
2A301
3'-0"8 TREADS @ 10" MIN
9 RISERS @ 7 1/4" MAX
W
D
18 20
33
32
31
30
34
35
UNIT 22050sf TOTAL
(E) 25'-9" LOT WIDTH
(E) 5
4'-9
" LOT
DEP
TH
(E) +
/- 8'
-4 3
/4"
3'-0
"3'
-0"
BAY WIDTH(E) +/- 9'-10 1/2"
BAY
DEPT
H(E
) +/-
2'-5
"
9 RISERS @ 7 1/4" MAX8 TREADS @ 10" MIN
C4
C1
C2
C1
C14
C1
C6
C23
C5C5C19
C23
C3
C15C8
C7
C7
C3C23
C2
C2
C5
C13
C14
C6C13
C24C20
PROPERTY LINE
C29
C30
C21
16
15 14
1917
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPOSEDLIGHTWELL
ATADJACENTPROPERTY
21
C2
PLAN LEGEND
X1
(E) CONSTRUCTION TO BE REMOVED
(N) NON-RATED PTN
(N) 1HR-RATED, INSULATED INT. PTN.
DASHED LINE INDICATES ADDITIONALBACKING TO BE MOUNTED. SEE 1/A111FOR LOCATIONS. PROVIDE BACKING FORMILLWORK A.R. ALL BACKING TO BECONCEALED
AREA NOT IN CONTRACT.
(N) 2HR-RATED, INSULATED INT. PTN.
(N) NON-RATED ACOUSTIC INT PTN.
(N) SWING DOOR
WALL TAG
(E) PTN TO REMAIN
01GP01
(N) DOOR TAG
(E) CONSTRUCTION TO BE REMOVED
(N) INT. TEMPERED GLASS PTN.
ITEMS OVERHEAD
HOSE BIB
GAS SHUTOFF VALVE
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:4
1 AM
A112
3RD & 4TH FLOORCONSTRUCTION PLANS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
1/4" = 1'-0"1 THIRD FLOOR CONSTRUCTION PLAN 1/4" = 1'-0"2 FOURTH FLOOR CONSTRUCTION PLAN
KEYNOTESCONSTRUCTION
C1 (N) APPLIANCES AND EQUIPMENTC2 (N) PLUMBING FIXTURES, TYP.C3 (N) BUILT-IN CASEWORKC4 (N) FULL HEIGHT BUILT-IN CASEWORKC5 (N) BASE CABINETS AND COUNTERSC6 (N) UPPER CABINETSC7 (N) GRIPPABLE HANDRAIL @ 36" ABOVE NOSING; DESIGN SHALL
RESIST LINEAR LOAD OF 50 PLF IN ACCORDANCE W/ SECTION 4.5.1OF ASCE 7 PER CBC 1607.8.1
C8 (N) GUARDRAIL @ 42" W/ 4" MAX OPENING; DESIGN SHALL RESISTLINEAR LOAD OF 50 PLF IN ACCORDANCE W/ SECTION 4.5.1 OFASCE 7 PER CBC 1607.8.1
C10 (N) TEMPERED GLASS SHOWER ENCLOSUREC11 (N) WINDOW TO BE OPERABLE AND COMPLY W/ EGRESS
REQUIREMENTS PER CBC 1029C13 (N) WASHER/DRYER AND HOOK UPS. VENT DRYER TO EXTERIORC14 (N) GAS SHUTOFFC15 (N) CARPENTER-BUILT STAIR; (3) 2X12 WOOD STRINGERS MIN 2/
3/4" PLYWOOD TREADS & RISERS; P.T. LUMBER AT ALL EXTERIORCONDITIONS
C19 (N) EXHAUST HOOD COMPLIANT WITH CBC 2013, EXTERIOR VENTC20 (N) PASSENGER ELEVATORC21 PROVIDE 5/8" GYPSUM BOARD ON UNDERSIDE OF STAIRSC23 (N) FLOOR INFILLC24 (N) MECHANICAL SPACEC29 (N) PAINTED WOOD GUARDRAILC30 MINIMUM 100 SQ. IN. LOUVER FOR MECHANICAL VENTILATION
GENERAL NOTESCONSTRUCTION PLAN (RES)
SEE SHEET A004 FOR ACCESSIBLE CLEARANCES & FURTHERINFORMATION ON RECEPTION DESKSEE GENERAL NOTES ON SHEET A002.
1 ALL (N) WALLS TYPE "A" U.O.N. SEE SCHEDULE, A901.2 ALL DIMENSIONS ARE TO FACE OF FINISH, CENTERLINE OF
OPENING OR EDGE OF JAMB FRAME, U.O.N.3 CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING.ARCHITECT TO REVIEW ALL CHALK LINES IN FIELD PRIOR TOSTUD INSTALLATION.
4 DOORS NOT LOCATED BY DIMENSION SHALL BE PLACED 3" OFFJAMB, U.O.N. REFER TO DOOR SCHEDULE FOR TYPES AND SIZESON SHEET A901.
5 PROVIDE & INSTALL FLASHING, COUNTERFLASHING, CAPFLASHING, METAL TRIM, OTHER FABRICATED ITEMS ANDMISCELLANEOUS SHEET METALWORK AT JUNCTIONS OF A ROOFAND WALL, AT CHIMNEYS, OVER EXPOSED DOORS ANDWINDOWS, AT CHANGES OF SIDING MATERIAL IN ROOF VALLEYSOR WHERE REQUIRED TO PROVIDE COMPLETE WATERTIGHT ANDWATERPROOF CONSTRUCTION.
6 PROVIDE & INSTALL ONE PIECE GSM PAN FLASHING AT ALL NEWAND REPLACEMENT EXTERIOR DOORS. COMPLY WITH ASTME2112-07, STANDARD PRACTICE FOR INSTALLATION OF EXTERIORWINDOWS, DOORS, AND SKYLIGHTS.
7 WATERPROOFING SHALL OVERLAP FLASHINGS FOR POSITIVEDRAINAGE AT ALL CONDITIONS.
8 FLASHING & SHEET METALWORK SHALL BE FABRICATED ANDINSTALLED IN ACCORDANCE WITH SHEET METAL & AIRCONDITIONING CONTRACTORS' NATIONAL ASSOCIATION(SMACNA) ARCHITECTURAL SHEET METAL MANUAL. COMPLYWITH MINIMUM THICKNESS OR GAGE REQUIREMENTS ASSPECIFIED IN SMACNA ARCHITECTURAL SHEET METAL MANUAL
9 ISOLATE AND PROTECT DISSIMILAR METALS FROM CONTACTWITH EACH OTHER BY APPLYING SPECIFIED ISOLATIONMATERIAL TO CONTACT SURFACES. PROTECT SURFACES OFSHEET METAL IN CONTACT WITH CONCRETE, TREATED WOOD, ORALUMINUM WITH A HEAVY COATING OF BITUMINOUS PAINT ASRECOMMENDED BY MANUFACTURER/FABRICATOR.
10 FLASHING & SHEET METALWORK WILL NOT BE MEASUREDSEPARATELY FOR PAYMENT BUT WILL BE PAID FOR AS PART OFTHE CONTRACT LUMP SUM PRICE FOR ARCHITECTURAL WORK.
11 PROVIDE MINIMUM OF R-19 BATT INSULATION IN EXTERIORWALLS ADJACENT TO LIVING SPACE.
12 PROVIDE CEMENT BOARD BACKING IN AREAS TO RECEIVE TILEFINISH.
13 WOOD LOCATED NEARER THAN 6" TO EARTH SHALL BE TREATEDWOOD.
14 ALL DOORS AND WINDOWS NOT TAGGED ARE EXISTING TOREMAIN U.O.N.
15 ALL TOILETS TO HAVE A MINIMUM CLEARANCE OF 24" IN FRONTAND 15" FROM CENTERLINE OF THE TOILET TO EACH SIDE.
16 STAIRWAYS SHALL HAVE A MINIMUM HEADROOM CLEARANCEOF 80 INCHES ABOVE THE FRONT EDGE OF THE NOSING.
17 ALL APPLIANCES WITH QUICK-ACTING VALVES, INCLUDING BUTNOT LIMITED TO DISHWASHERS & CLOTHES WASHERS, SHALLHAVE WATER HAMMER ARRESTORS (CPC 609.10).
18 ALL EXISTING NON-COMPLIANT AND NEW PLUMBING FIXTURESSHALL COMPLY WITH CALIFORNIA SB-407 (2009).
19 WATER HEATERS SHALL HAVE SEISMIC STRAPPING AT A POINTWITHIN THE UPPER 1/3 AND THE LOWER 1/3 OF THE WATERHEATER’S VERTICAL DIMENSIONS. AT THE LOWER POINT, AMINIMUM DISTANCE OF FOUR (4) INCHES SHALL BE MAINTAINEDABOVE THE CONTROLS TO THE STRAP. (CPC 507.2).
20 KITCHEN RANGES SHALL BE PROVIDED WITH A METALVENTILATING HOOD. A VERTICAL CLEARANCE OF 24" MINIMUMBETWEEN THE COOKTOP & METAL VENTILATING HOOD SHALLBE MAINTAINED. THE HOOD SHALL BE AS WIDE AS THE RANGEAND CENTERED OVER THE UNIT. THE METAL HOOD SHALL BE0.0122" MINIMUM THICK (2013 CMC 920.3).
21 KITCHEN IS REQUIRED TO HAVE AN EXHAUST FAN DUCTED TOTHE OUTSIDE WITH A MINIMUM VENTILATION RATE OF 100 CFM.
22 ALL EXHAUST FAN DUCTING, INCLUDING BUT NOT LIMITED TO TOKITCHEN AND BATHROOM EXHAUST FANS, SHALL BE SIZEDACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1.
23 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL BEACCESSIBLE THROUGH AN OPENING AND PASSAGEWAY ATLEAST AS LARGE AS THE LARGEST COMPONENT OF THEAPPLIANCE, AND NOT LESS THAN 22 INCHES BY 30 INCHES. (CPC508.4).
24 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL HAVEA SOLID FLOOR PASSAGEWAY OF NOT LESS THAN 24 INCHESAND A WORK PLATFORM OF NOT LESS THAN 30 INCHES BY 30INCHES IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CPC508.4.2 & 508.4.3).
25 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL HAVEA PERMANENT 120-VOLT RECEPTACLE OUTLET AND A LIGHTINGFIXTURE NEAR THE APPLIANCE. (CPC 508.4.4).
26 ALL GLASS SHALL BE BIRD SAFE GLAZING PER SAN FRANCISCOSTANDARDS FOR BIRD SAFE BUILDINGS.
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.2016
-
HB
G
A2042
A202
A203
A201
2
2
2
477 SF
(N) PRIVATE ROOFDECK
2A301
23'-9
"
(E) 5
4'-9
" LOT
DEP
TH
(E) 25'-9" LOT WIDTH
BAY WINDOW BELOW(E) +/- 9'-10 1/2"
WIN
DOW
BEL
OW(E
) +/-
2'-5
" BAY
UNIT 2
3'-0"7 TREADS @ 10" MIN
8 RISERS @ 7 1/4" MAX
3'-0
"
40' - 0"
C8
C7
C7
C15C15
C25C25
C8
C26
C26
PROPERTY LINE
(PROPOSED NEWRESIDENCE UNDERPERMIT#2015.1113.2622 AND2015.1113.2623)
PROPOSEDLIGHTWELL
ATADJACENTPROPERTY
MIN
5'-0
"
MIN
5'-0
"
MIN5'-0"
MIN5'-0"
9'-9"
C8
C8
C8
C8
SL1M
IN2'
-6"
MIN
2'-6
"C32
PLAN LEGEND
X1
(E) CONSTRUCTION TO BE REMOVED
(N) NON-RATED PTN
(N) 1HR-RATED, INSULATED INT. PTN.
DASHED LINE INDICATES ADDITIONALBACKING TO BE MOUNTED. SEE 1/A111FOR LOCATIONS. PROVIDE BACKING FORMILLWORK A.R. ALL BACKING TO BECONCEALED
AREA NOT IN CONTRACT.
(N) 2HR-RATED, INSULATED INT. PTN.
(N) NON-RATED ACOUSTIC INT PTN.
(N) SWING DOOR
WALL TAG
(E) PTN TO REMAIN
01GP01
(N) DOOR TAG
(E) CONSTRUCTION TO BE REMOVED
(N) INT. TEMPERED GLASS PTN.
ITEMS OVERHEAD
HOSE BIB
GAS SHUTOFF VALVE
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:4
2 AM
A113
ROOF CONSTRUCTIONPLAN
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
1/4" = 1'-0"1 ROOF CONSTRUCTION PLAN
KEYNOTESCONSTRUCTION
C7 (N) GRIPPABLE HANDRAIL @ 36" ABOVE NOSING; DESIGN SHALLRESIST LINEAR LOAD OF 50 PLF IN ACCORDANCE W/ SECTION 4.5.1OF ASCE 7 PER CBC 1607.8.1
C8 (N) GUARDRAIL @ 42" W/ 4" MAX OPENING; DESIGN SHALL RESISTLINEAR LOAD OF 50 PLF IN ACCORDANCE W/ SECTION 4.5.1 OFASCE 7 PER CBC 1607.8.1
C15 (N) CARPENTER-BUILT STAIR; (3) 2X12 WOOD STRINGERS MIN 2/3/4" PLYWOOD TREADS & RISERS; P.T. LUMBER AT ALL EXTERIORCONDITIONS
C25 (N) DECK PAVERS ON ADJUSTABLE PEDASTALS - PAVERS TO BENONCOMBUSTABLE PER SFBC SECTIONS 104A.2.8 AND 1509.6
C26 (N) RATED PARAPETS @ 42" ABOVE FINISHED DECKC32 (N) 1-HOUR FIRE-RATED PARAPET, MINIMUM 30" A.F.R.
GENERAL NOTESCONSTRUCTION PLAN (RES)
SEE SHEET A004 FOR ACCESSIBLE CLEARANCES & FURTHERINFORMATION ON RECEPTION DESKSEE GENERAL NOTES ON SHEET A002.
1 ALL (N) WALLS TYPE "A" U.O.N. SEE SCHEDULE, A901.2 ALL DIMENSIONS ARE TO FACE OF FINISH, CENTERLINE OF
OPENING OR EDGE OF JAMB FRAME, U.O.N.3 CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING.ARCHITECT TO REVIEW ALL CHALK LINES IN FIELD PRIOR TOSTUD INSTALLATION.
4 DOORS NOT LOCATED BY DIMENSION SHALL BE PLACED 3" OFFJAMB, U.O.N. REFER TO DOOR SCHEDULE FOR TYPES AND SIZESON SHEET A901.
5 PROVIDE & INSTALL FLASHING, COUNTERFLASHING, CAPFLASHING, METAL TRIM, OTHER FABRICATED ITEMS ANDMISCELLANEOUS SHEET METALWORK AT JUNCTIONS OF A ROOFAND WALL, AT CHIMNEYS, OVER EXPOSED DOORS ANDWINDOWS, AT CHANGES OF SIDING MATERIAL IN ROOF VALLEYSOR WHERE REQUIRED TO PROVIDE COMPLETE WATERTIGHT ANDWATERPROOF CONSTRUCTION.
6 PROVIDE & INSTALL ONE PIECE GSM PAN FLASHING AT ALL NEWAND REPLACEMENT EXTERIOR DOORS. COMPLY WITH ASTME2112-07, STANDARD PRACTICE FOR INSTALLATION OF EXTERIORWINDOWS, DOORS, AND SKYLIGHTS.
7 WATERPROOFING SHALL OVERLAP FLASHINGS FOR POSITIVEDRAINAGE AT ALL CONDITIONS.
8 FLASHING & SHEET METALWORK SHALL BE FABRICATED ANDINSTALLED IN ACCORDANCE WITH SHEET METAL & AIRCONDITIONING CONTRACTORS' NATIONAL ASSOCIATION(SMACNA) ARCHITECTURAL SHEET METAL MANUAL. COMPLYWITH MINIMUM THICKNESS OR GAGE REQUIREMENTS ASSPECIFIED IN SMACNA ARCHITECTURAL SHEET METAL MANUAL
9 ISOLATE AND PROTECT DISSIMILAR METALS FROM CONTACTWITH EACH OTHER BY APPLYING SPECIFIED ISOLATIONMATERIAL TO CONTACT SURFACES. PROTECT SURFACES OFSHEET METAL IN CONTACT WITH CONCRETE, TREATED WOOD, ORALUMINUM WITH A HEAVY COATING OF BITUMINOUS PAINT ASRECOMMENDED BY MANUFACTURER/FABRICATOR.
10 FLASHING & SHEET METALWORK WILL NOT BE MEASUREDSEPARATELY FOR PAYMENT BUT WILL BE PAID FOR AS PART OFTHE CONTRACT LUMP SUM PRICE FOR ARCHITECTURAL WORK.
11 PROVIDE MINIMUM OF R-19 BATT INSULATION IN EXTERIORWALLS ADJACENT TO LIVING SPACE.
12 PROVIDE CEMENT BOARD BACKING IN AREAS TO RECEIVE TILEFINISH.
13 WOOD LOCATED NEARER THAN 6" TO EARTH SHALL BE TREATEDWOOD.
14 ALL DOORS AND WINDOWS NOT TAGGED ARE EXISTING TOREMAIN U.O.N.
15 ALL TOILETS TO HAVE A MINIMUM CLEARANCE OF 24" IN FRONTAND 15" FROM CENTERLINE OF THE TOILET TO EACH SIDE.
16 STAIRWAYS SHALL HAVE A MINIMUM HEADROOM CLEARANCEOF 80 INCHES ABOVE THE FRONT EDGE OF THE NOSING.
17 ALL APPLIANCES WITH QUICK-ACTING VALVES, INCLUDING BUTNOT LIMITED TO DISHWASHERS & CLOTHES WASHERS, SHALLHAVE WATER HAMMER ARRESTORS (CPC 609.10).
18 ALL EXISTING NON-COMPLIANT AND NEW PLUMBING FIXTURESSHALL COMPLY WITH CALIFORNIA SB-407 (2009).
19 WATER HEATERS SHALL HAVE SEISMIC STRAPPING AT A POINTWITHIN THE UPPER 1/3 AND THE LOWER 1/3 OF THE WATERHEATER’S VERTICAL DIMENSIONS. AT THE LOWER POINT, AMINIMUM DISTANCE OF FOUR (4) INCHES SHALL BE MAINTAINEDABOVE THE CONTROLS TO THE STRAP. (CPC 507.2).
20 KITCHEN RANGES SHALL BE PROVIDED WITH A METALVENTILATING HOOD. A VERTICAL CLEARANCE OF 24" MINIMUMBETWEEN THE COOKTOP & METAL VENTILATING HOOD SHALLBE MAINTAINED. THE HOOD SHALL BE AS WIDE AS THE RANGEAND CENTERED OVER THE UNIT. THE METAL HOOD SHALL BE0.0122" MINIMUM THICK (2013 CMC 920.3).
21 KITCHEN IS REQUIRED TO HAVE AN EXHAUST FAN DUCTED TOTHE OUTSIDE WITH A MINIMUM VENTILATION RATE OF 100 CFM.
22 ALL EXHAUST FAN DUCTING, INCLUDING BUT NOT LIMITED TO TOKITCHEN AND BATHROOM EXHAUST FANS, SHALL BE SIZEDACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1.
23 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL BEACCESSIBLE THROUGH AN OPENING AND PASSAGEWAY ATLEAST AS LARGE AS THE LARGEST COMPONENT OF THEAPPLIANCE, AND NOT LESS THAN 22 INCHES BY 30 INCHES. (CPC508.4).
24 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL HAVEA SOLID FLOOR PASSAGEWAY OF NOT LESS THAN 24 INCHESAND A WORK PLATFORM OF NOT LESS THAN 30 INCHES BY 30INCHES IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CPC508.4.2 & 508.4.3).
25 APPLIANCES IN ATTIC AND UNDER-FLOOR SPACES SHALL HAVEA PERMANENT 120-VOLT RECEPTACLE OUTLET AND A LIGHTINGFIXTURE NEAR THE APPLIANCE. (CPC 508.4.4).
26 ALL GLASS SHALL BE BIRD SAFE GLAZING PER SAN FRANCISCOSTANDARDS FOR BIRD SAFE BUILDINGS.
1
1
1
1
1
1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(E) T.O.CURB0' - 0"
ADJACENT NEIGHBOR1926, 1928, 1930 TAYLOR STREET
(D)
(D)(D)
(D)
(D)
(D)(D)
(E) STREET GRADE
11
55
34
22
1919
6PROPOSED NEW RESIDENCEAT 870 UNION STREET PERMIT#2015.1113.2622 AND 2015.1113.2623
(E) 2
1'-8
3/4
" BAY
WIN
DOW
13
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(N) FIRST FLOOR0' - 0"
(N) T.O.DECK40' - 0"
(N) FOURTH FLOOR29' - 2 1/2"
(N) THIRD FLOOR19' - 1"
(N) SECOND FLOOR9' - 6 1/4"
(N) T.O.PENTHOUSE48' - 0"
3'-6
1/4
"3'
-6 1
/4"
(N) T.O.ROOF39' - 9 1/4"
2'-1
3/4
"
(E) +
/- 21
'-8 3
/4" B
AY W
INDO
W3'
-6"
(N)(N)
(N)(N)
(N)(N) (N)
(N)
(N)
(N)(N)
ADJACENT NEIGHBOR1926, 1928, 1930 TAYLOR STREET
PROPOSED NEW RESIDENCEAT 870 UNION STREET PERMIT#2015.1113.2622 AND 2015.1113.2623
(E) STREET GRADE
0'-1
0"
2020 1111
11 51
(N)
29292929
2929
29
29
29
19
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:4
6 AM
A201
EXTERIOR ELEVATIONS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
3/16" = 1'-0"1 EXISTING FRONT ELEVATION (SOUTH)
3/16" = 1'-0"2 PROPOSED FRONT ELEVATION (SOUTH)
KEYNOTESEXTERIOR ELEVATION
(D) (E) DOOR OR WINDOW TO REMAIN(N) (N) DOOR OR WINDOW, SEE SCHEDULE A901 AND A9021 (E) PAINTED WOOD SIDING TO BE REMOVED2 (E) PAINTED WOOD SHINGLE SIDING TO BE REPLACED IN KIND3 (E) ENTRY CONCRETE STAIR TO BE REMOVED4 REMOVE PORTION OF (E) CURB TO ACCOMMODATE (N) GARAGE
ENTRY5 (E) CONCRETE FINISH TO REMAIN6 (E) PAINTED WOOD STAIRS TO BE REMOVED9 (N) PAINTED METAL GUARDRAIL11 (N) PAINTED METAL FINISH13 PORTION OF (E) BAY WINDOW TO BE REMOVED TO
ACCOMMODATE (N) CONSTRUCTION19 (E) PAINTED WOOD SHINGLE SIDING TO BE REMOVED20 (N) PAINTED WOOD SHINGLE SIDING29 (N) WINDOW GLASS FACE TO BE SET BACK MINIMUM 3" FROM
PRIMARY WALL FACE1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) T.O.CURB0' - 0"
(D)
(D)
(D)
(D)
(D)
(D)
(D)
(D)
(D)
ADJACENT NEIGHBOR1920, 1922, 1924 TAYLOR STREET
(E) REAR T.O.ROOF36' - 7 7/8"
PROPOSED NEW RESIDENCEAT 870 UNION STREET PERMIT#2015.1113.2622 AND 2015.1113.2623
(E) T.O.CURB @ ALADDIN TERRACE
SIDE PROPERTY LINE SIDE PROPERTY LINE
21
22
2525
2323
22
11
1
24
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(N) FIRST FLOOR0' - 0"
(N) T.O.DECK40' - 0"
(N) FOURTH FLOOR29' - 2 1/2"
(N) THIRD FLOOR19' - 1"
(N) SECOND FLOOR9' - 6 1/4"
(N) T.O.PENTHOUSE48' - 0"
(N) T.O.ROOF39' - 9 1/4"0
'-9 1
/4"
ADJACENT NEIGHBOR1920, 1922, 1924 TAYLOR STREET
(N)
(N)(N)
(N)(N)
(N)
(N)
(N)
(N)(N)
(N)(N)(N)
2'-1
3/4
"3'
-6 1
/4"
3'-6
1/4
"0'
-10"
PROPOSED NEW RESIDENCEAT 870 UNION STREET PERMIT#2015.1113.2622 AND 2015.1113.2623
9
22
2020
9
15
26
15
26
SIDE PROPERTY LINE SIDE PROPERTY LINE
27
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:5
0 AM
A202
EXTERIOR ELEVATIONS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
3/16" = 1'-0"1 EXISTING REAR ELEVATION (NORTH)
3/16" = 1'-0"2 PROPOSED REAR ELEVATION (NORTH)
KEYNOTESEXTERIOR ELEVATION
(D) (E) DOOR OR WINDOW TO REMAIN(N) (N) DOOR OR WINDOW, SEE SCHEDULE A901 AND A9021 (E) PAINTED WOOD SIDING TO BE REMOVED2 (E) PAINTED WOOD SHINGLE SIDING TO BE REPLACED IN KIND9 (N) PAINTED METAL GUARDRAIL15 (N) CONCRETE RETAINING WALL20 (N) PAINTED WOOD SHINGLE SIDING21 ROOF LINE BEYOND22 (E) WOOD STAIRS TO BE REMOVED23 AREA OF REAR YARD TO BE EXCAVATED TO ACCOMMODATE (N)
WORK24 (E) LOW BRICK WALL TO BE REMOVED25 (E) BAY TO BE REMOVED26 (N) PAINTED WOOD GUARDRAIL27 (N) CARPENTER-BUILT STAIR; (3) 2X12 WOOD STRINGERS MIN 2/
3/4" PLYWOOD TREADS & RISERS; P.T. LUMBER AT ALL EXTERIORCONDITIONS
1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(E) T.O.CURB0' - 0"
(D) (D)
(D) (D)
(D)
(D)(D)
(E) REAR T.O.ROOF36' - 7 7/8"
ADJACENT NEIGHBOR1920, 1922, 1924 TAYLOR STREET
IN FOREGROUND
ADJACENT NEIGHBOR1926, 1928, 1930 TAYLOR STREETIN FOREGROUND
FRONT PROPERTY LINE REAR PROPERTY LINE
(E) 2
1'-8
3/4
" BAY
WIN
DOW
13
12
22
2
22
11
11
21
55
PROPOSED NEW RESIDENCEAT 870 UNION STREET PERMIT#2015.1113.2622 AND 2015.1113.2623 INBACKGROUND
22
2323
25
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(N) FIRST FLOOR0' - 0"
(N) T.O.DECK40' - 0"
(N) FOURTH FLOOR29' - 2 1/2"
(N) THIRD FLOOR19' - 1"
(N) SECOND FLOOR9' - 6 1/4"
(N) T.O.PENTHOUSE48' - 0"
(N) T.O.ROOF39' - 9 1/4"
(E) +
/- 21
'-8 3
/4" B
AY W
INDO
W
ADJACENT NEIGHBOR1920, 1922, 1924 TAYLOR STREET
IN FOREGROUND
ADJACENT NEIGHBOR1926, 1928, 1930 TAYLOR STREETIN FOREGROUND
2'-1
3/4
"3'
-6 1
/4"
3'-6
1/4
"
0'-1
0"
26
11
FRONT PROPERTY LINE REAR PROPERTY LINE
28
2020
21
(N)
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:5
5 AM
A203
EXTERIOR ELEVATIONS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
3/16" = 1'-0"1 EXISTING SIDE ELEVATION (EAST)
3/16" = 1'-0"2 PROPOSED SIDE ELEVATION (EAST)
KEYNOTESEXTERIOR ELEVATION
(D) (E) DOOR OR WINDOW TO REMAIN(N) (N) DOOR OR WINDOW, SEE SCHEDULE A901 AND A9021 (E) PAINTED WOOD SIDING TO BE REMOVED2 (E) PAINTED WOOD SHINGLE SIDING TO BE REPLACED IN KIND5 (E) CONCRETE FINISH TO REMAIN11 (N) PAINTED METAL FINISH12 (E) BAY TO REMAIN13 PORTION OF (E) BAY WINDOW TO BE REMOVED TO
ACCOMMODATE (N) CONSTRUCTION20 (N) PAINTED WOOD SHINGLE SIDING21 ROOF LINE BEYOND22 (E) WOOD STAIRS TO BE REMOVED23 AREA OF REAR YARD TO BE EXCAVATED TO ACCOMMODATE (N)
WORK25 (E) BAY TO BE REMOVED26 (N) PAINTED WOOD GUARDRAIL28 (N) STEPPED CONCRETE FOUNDATION
1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(E) T.O.CURB0' - 0"
(E) REAR T.O.ROOF36' - 7 7/8"
(D)(D)
(D)
(D)(D)
(D)
(D)
(D)(D)
(D) (D)
PROPOSED NEW RESIDENCEAT 870 UNION STREET PERMIT#2015.1113.2622 AND2015.1113.2623 IN FOREGROUND
REAR PROPERTY LINEFRONT PROPERTY LINE
13
(E) 2
1'-8
3/4
" BAY
WIN
DOW
12
221
24
22
25
1111
221919
22
2323
ADJACENT NEIGHBOR1920, 1922, 1924 TAYLOR
STREET IN BACKGROUNDADJACENT NEIGHBOR1926, 1928, 1930 TAYLORSTREET IN BACKGROUND
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(N) FIRST FLOOR0' - 0"
(N) T.O.DECK40' - 0"
(N) FOURTH FLOOR29' - 2 1/2"
(N) THIRD FLOOR19' - 1"
(N) SECOND FLOOR9' - 6 1/4"
(N) T.O.PENTHOUSE48' - 0"
(N) T.O.ROOF39' - 9 1/4"
PROPOSED NEW RESIDENCEAT 870 UNION STREET PERMIT#
2015.1113.2622 AND2015.1113.2623 IN FOREGROUND
0'-9
1/4
"21
'-8 3
/4"
2'-1
3/4
"3'
-6 1
/4"
3'-6
1/4
"0'
-10"
REAR PROPERTY LINE FRONT PROPERTY LINE
2815
2020
26
11
21
ADJACENT NEIGHBOR1920, 1922, 1924 TAYLOR STREET
IN BACKGROUND
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
38:5
9 AM
A204
EXTERIOR ELEVATIONS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
3/16" = 1'-0"1 EXISTING SIDE ELEVATION (WEST)
3/16" = 1'-0"2 PROPOSED SIDE ELEVATION (WEST)
KEYNOTESEXTERIOR ELEVATION
(D) (E) DOOR OR WINDOW TO REMAIN1 (E) PAINTED WOOD SIDING TO BE REMOVED2 (E) PAINTED WOOD SHINGLE SIDING TO BE REPLACED IN KIND11 (N) PAINTED METAL FINISH12 (E) BAY TO REMAIN13 PORTION OF (E) BAY WINDOW TO BE REMOVED TO
ACCOMMODATE (N) CONSTRUCTION15 (N) CONCRETE RETAINING WALL19 (E) PAINTED WOOD SHINGLE SIDING TO BE REMOVED20 (N) PAINTED WOOD SHINGLE SIDING21 ROOF LINE BEYOND22 (E) WOOD STAIRS TO BE REMOVED23 AREA OF REAR YARD TO BE EXCAVATED TO ACCOMMODATE (N)
WORK24 (E) LOW BRICK WALL TO BE REMOVED25 (E) BAY TO BE REMOVED26 (N) PAINTED WOOD GUARDRAIL28 (N) STEPPED CONCRETE FOUNDATION
1
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.20161 SITE PERMIT REVISION 1 08.22.2017
-
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(E) T.O.CURB0' - 0"
(E) OFFICE(E) STORAGE
(E) DINING ROOM (E) LIVING ROOM (E) BATH (E) BEDROOM
(E) LIVING/DINING ROOM
(E) KITCHEN(E) BATH(E) BEDROOM(E) BEDROOM
(E) C
LOSE
T
(E) +
/- 9'
-3 1
/2"
(E) +
/- 9'
-3 3
/4"
(E) +
/- 7'
-4"
(E) REAR T.O.ROOF36' - 7 7/8"
UNIT 1
UNIT 2
AREA TO BE EXCAVATED (498 SQ.FT)
(E) 2
1'-8
3/4
" BAY
WIN
DOW
(E) FIRST FLOOR7' - 4 1/2"
(E) SECOND FLOOR15' - 6 3/4"
(E) THIRD FLOOR25' - 8 1/4"
(E) FRONT T.O.ROOF38' - 11 3/8"
(N) FIRST FLOOR0' - 0"
(N) T.O.DECK40' - 0"
(N) FOURTH FLOOR29' - 2 1/2"
(N) THIRD FLOOR19' - 1"
(N) SECOND FLOOR9' - 6 1/4"
(N) T.O.PENTHOUSE48' - 0"
(N) ELEVATORVESTIBULE
(N) MASTERBEDROOM
(N) PRIVATE REARDECK
(N) BEDROOM
CLOS
ET LIVING ROOMDINING ROOM
(N) BEDROOM(N) MASTERBEDROOM
(N) FLEX ROOM (N) LIVING/ DINING
HALL
WAY
ROOF DECK
(N) HALLWAY
(N) GARAGE
(E) +
/- 9'
-3 1
/2"
(E) +
/- 9'
-3 3
/4"
(N) 8
'-9"
(N) 8
'-8 1
/2"
(N) 9
'-2 1
/2"
(N) LOWERREAR YARD
(N) T.O.ROOF39' - 9 1/4"
2'-1
3/4
"3'
-6 1
/4"
3'-6
1/4
"0'
-10"
3'-6
"(E
) +/-
21'-8
3/4
" BAY
WIN
DOW
UNIT 2
UNIT 2
UNIT 1
UNIT 1
EXCAVATION AREA
FIRST FLOOR 25'-9 LOT WIDTH x 498 SQ.FT = 12,823.5 CU.FT
12,823.5 CU.FT x 1 CU.YD/27 CU.FT= 474.9 CU.YD
Project Number:
SHEET NUMBER
101 Montgomery Street Suite 650San Francisco, CA 94104
T 415 346 9990
Drawn By:Checked By:
8/23
/201
7 8:
39:0
1 AM
A301
BUILDING SECTIONS
1639.1
33-35 ALADDINTERRACE
REMODEL &ADDITION
SITE PERMIT SET REVISION 1
33-35 ALADDIN TERRACESAN FRANCISCO, CA 94133
AWBE
3/16" = 1'-0"1 EXISTING BUILDING SECTION
3/16" = 1'-0"2 PROPOSED BUILDING SECTION
N0. RECORD OF DRAWING ISSUANCE DATE
0 SITE PERMIT SET 08.16.2016
170822 - 33-35 Aladdin Terrace - Revised Site Permit Se_311 Sett.pdfSheetsA001 - TITLE SHEETA002A - EXISTING SITE PLANA002B - PROPOSED SITE PLANA003 - EXISTING CONDITIONS - PHOTOGRAPHSA004A - SECTION 317B CALCULATIONSA004B - SECTION 317B CALCULATIONSA101 - FIRST & SECOND FLOOR EXISTING/DEMO PLANSA102 - THIRD FLOOR & ROOF EXISTING/DEMO PLANSA111 - 1ST & 2ND FLOOR CONSTRUCTION PLANA112 - 3RD & 4TH FLOOR CONSTRUCTION PLANSA113 - ROOF CONSTRUCTION PLANA201 - EXTERIOR ELEVATIONSA202 - EXTERIOR ELEVATIONSA203 - EXTERIOR ELEVATIONSA204 - EXTERIOR ELEVATIONSA301 - BUILDING SECTIONSA901 - SCHEDULESA902 - SCHEDULES