dorel europe safety center - unece homepage · 2009-10-20 · dorel europe safety center force...
TRANSCRIPT
![Page 1: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/1.jpg)
Dorel Europe Safety Dorel Europe Safety CenterCenter
Force transmitted by Support leg
Julien KERDREUXFrançois RENAUDIN
Erik SALTERSYoann BRUNETIERE
![Page 2: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/2.jpg)
SummarySummary
• Target• Description of the tests
– Pulses– Measurement device– Type of seats tested– Type of floor flexibility
• Analysis– Force level– Dummy criteria
• Conclusion
![Page 3: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/3.jpg)
Target of the StudyTarget of the Study
1. Measurement of load level transmitted by Support legs on the floor.
2. Evaluation of dummy safety criteria with floor flexibility
![Page 4: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/4.jpg)
Description of the testsDescription of the tests
Pulses
Using a R44 bench 2 types of pulses were applied on each type of seat tested
R44 Pulse
![Page 5: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/5.jpg)
Description of the testsDescription of the tests
Pulses
Using a R44 bench 2 types of pulses were applied on each type of seat tested
Euroncap type pulse
![Page 6: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/6.jpg)
Description of the testsDescription of the tests
Measurement Device
Load Sensor :Mono AxialMax Load 500 DaN/sensor
Support Leg
Load sensor * 4
Rigid floor
R44 Bench
Sled
![Page 7: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/7.jpg)
Description of the testsDescription of the tests
Type of Seats
Seat A :
Group 1 FWF
Maxi Cosi Priorifix
Weight : 14.6 kg
![Page 8: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/8.jpg)
Description of the testsDescription of the tests
Type of Seats
Seat B :
Group 1 RWF
Recaro Polaric
Weight : 13.6 kg
![Page 9: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/9.jpg)
Description of the testsDescription of the tests
Type of Seats
Seat C :Group 0+ RWFMaxi Cosi Cabriofix+ Easyfix baseWeight : 12.2 kg
Tests performed only in R44
![Page 10: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/10.jpg)
Description of the testsDescription of the tests
Type of Floor
Different type of 50 mm thick materials were placed on the initial bench floor:
• A rigid spacer• A 84 g/l foam• A 35 g/l foam• A 25 g/l foam
The different foam were given by Renault. They seem to be EPP foams
25 g/l35 g/l
84 g/l
![Page 11: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/11.jpg)
Analysis of ResultsAnalysis of Results
Force to the Floor – R44
Gr1 RWF Seat B
Gr1 FWF Seat A
Gr0+ RWF Seat C
SeatA
PrioriFix
BRecaro Polaric
CCabrioFix (EasyFix)
Dummy P3 P3 P1.5 Maximum Force (N) 3956 5681 2750
![Page 12: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/12.jpg)
Analysis of ResultsAnalysis of Results
Force to the Floor – EuroNcap
Gr1 RWF Seat B
Gr1 FWF Seat A
SeatA
PrioriFix
BRecaro Polaric
Dummy P3 P3 Maximum Force (N) 4295 6334
![Page 13: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/13.jpg)
Analysis of ResultsAnalysis of Results
Force to the Floor / Floor Flexibility / R44
R44
2500
3000
3500
4000
4500
5000
5500
6000
∞ 84 35.5 25
Material Floor density (kg/m3)
Max
imu
m F
orc
ei (
N)
Seat C CabrioFix Seat A PrioriFix Seat B Polaric
R44
0
10
20
30
40
50
60
∞ 84 35.5 25
Material Floor density (kg/m3)
Max
imum
cru
sh (
mm
)
Seat C CabrioFix Seat A PrioriFix Seat B Polaric
![Page 14: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/14.jpg)
Analysis of ResultsAnalysis of Results
Force to the Floor / Floor Flexibility
EuroNcap
0
1000
2000
3000
4000
5000
6000
7000
8000
∞ 84 35.5
Material Floor density
Max
imum
For
ce (
N)
Seat A PrioriFIx Seat B Polaric
EuroNcap
0
10
20
30
40
50
60
∞ 84 35.5
Material Floor density
Max
imum
Cru
sh (
mm
)
Seat A PrioriFIx Seat B Polaric
![Page 15: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/15.jpg)
Analysis of ResultsAnalysis of Results
Force to the lower Isofix Anchorages – R44
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
Max
imum
For
ce (
N)
∞ 84 35.5 25
Floor Density (kg/m3)
R44 - Lower Anchorage Maximum Load
Seat A PrioriFix Seat C CabrioFix Seat B Polaric
![Page 16: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/16.jpg)
Analysis of ResultsAnalysis of Results
Dummy criteria – Head Excursion Seat A
R44
355
360
365
370
375
380
385
390
395
400
405
410
0 10 20 30 40 50 60
Crush (mm)
Hea
d D
isp
lace
men
t /C
r (m
m)
PrioriFix
![Page 17: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/17.jpg)
Analysis of ResultsAnalysis of Results
Dummy criteria – Head Excursion Seat B and C
R44
510
520
530
540
550
560
570
580
590
0 5 10 15 20 25 30 35 40 45 50
Crush (mm)
Hea
d D
isp
lace
men
t / C
r (m
m)
Seat B Polaric Seat C Cabriofix
![Page 18: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/18.jpg)
Analysis of ResultsAnalysis of Results
Dummy criteria – Thorax and Head Acceleration
R44
0
10
20
30
40
50
60
acce
lera
tion
(g)
∞ 84 35.5
Floor Density (kg/m3)
R44 Head Acceleration
Seat A Priorifix Seat B Polaric Seat C Cabriofix
0
5
10
15
20
25
30
35
40
45
acce
lera
tion
(g)
∞ 84 35.5
Floor Density (kg/m3)
R44 Chest Acceleration
Seat A Priorifix Seat B Polaric Seat C Cabriofix
![Page 19: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/19.jpg)
Analysis of ResultsAnalysis of Results
Dummy criteria – Thorax and Head Acceleration
R44
44
46
48
50
52
54
56
acce
lera
tion
(g)
∞ 84 35.5
Floor Density (kg/m3)
EuroNcap Head Acceleration
Seat A Priorifix Seat B Polaric
0
10
20
30
40
50
60
acce
lera
tion
(g)
∞ 84 35.5
Floor Density (kg/m3)
EuroNcap Chest Acceleration
Seat A Priorifix Seat B Polaric
![Page 20: Dorel Europe Safety Center - UNECE Homepage · 2009-10-20 · Dorel Europe Safety Center Force transmitted by Support leg JulienKERDREUX François RENAUDIN Erik SALTERS YoannBRUNETIERE](https://reader030.vdocument.in/reader030/viewer/2022040510/5e59d58b8162250c1b130301/html5/thumbnails/20.jpg)
ConclusionConclusion
• Force transmitted by support leg are dependant of CRS weight and configuration.
• The highest load are given by Gr1 Rearward Facing.• The floor flexibility range given by Renault were either too
stiff without big deformation or too soft reaching the maximum available deformation.
• The floor flexibility didn’t show significant increase of Head or Thorax deceleration
• The support leg intrusion into the floor can produce increase of Head Displacement and must be limited.