Download - 09 Introduction to GENEX Probe (Ver1.4)
![Page 1: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/1.jpg)
www.huawei.com Huawei confidential, 2007-10
Huawei GENEX Series
![Page 2: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/2.jpg)
2
www.huawei.com Huawei confidential, 2007-10
2
Objectives
Upon completion of this course,
you will be able to:
• Master data collection method of DT
• Master how to use GENEX Probe to
collect drive test data
![Page 3: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/3.jpg)
3
www.huawei.com Huawei confidential, 2007-10
3
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data Collection
Other Features
Case Study
![Page 4: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/4.jpg)
4
www.huawei.com Huawei confidential, 2007-10
4
RNC
GENEX U-Net
Radio Network Planning Tool
Downlink + Uplink
GENEX Probe
GENEX Assistant
Test & Post-Process Tools
GENEX Nastar
Network Performance Analysis System
GENEX U-Net is a radio planning
tool that fully supports the
technologies of GSM,GPRS-EDGE,
CDMA IS95,
WCDMA/UMTS/HSDPA/HSUPA,
CDMA 2000/1xRTT/1xEVDO, and
TD-SCDMA wireless networks.
The GENEX Probe, network
optimization and drive test data
collection system, is an air
interface test tool for
WCDMA/HSDPA/HSUPA/GSM/GP
RS networks.
GENEX Assistant is a
professional wireless test data
post-processing software system.
GENEX Nastar is a platform for
monitoring and optimizing the
performance of
GSM/CDMA/WCDMA wireless
networks
Huawei GENEX Family
![Page 5: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/5.jpg)
5
www.huawei.com Huawei confidential, 2007-10
5
Whole Flow Overview
Radio Network Planning Tool
Air Interface Test Tool and Post-
Processing Tool
Network Performance Analysis
Tool
Make full use of 2G resources
GENEX covers the
network lifecycle
![Page 6: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/6.jpg)
6
www.huawei.com Huawei confidential, 2007-10
6
GENEX Partners in The World
Applied in the Huawei 2G and 3G planning and
optimization projects
Covers more than forty countries, including commercial
and pilot offices
Assists the renowned operators in establishing and
optimizing the network with high quality.
The network operators include but not limited to: China
Mobile, China Unicom, China Telecom, China Netcom,
Vodafone, PBTL, T-Mobile, Orange, CellPlus,
PCCW(Sunday), Telecom, eMobile.
Aims at consistently providing the customers with
professional and high-level solutions for network planning and
optimization.
Employed by network operators and designing institutes all
over 26 provinces and municipalities
Integrates the experiences of renowned operators, advancing
with customers hand by hand.
![Page 7: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/7.jpg)
7
www.huawei.com Huawei confidential, 2007-10
7
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data Collection
Other Features
Case Study
![Page 8: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/8.jpg)
8
www.huawei.com Huawei confidential, 2007-10
8
GENEX Probe drive test system
GARMIN Series
GPS
DTI Scanner
(Built-in GPS)Anritsu
Scanner
Trimble Series
GPS
Qualcomm TM6250/
6275
AT Command
Supported Mobile
Huawei WCDMA/HSDPA
Data card
*Support WCDMA
1800/1900/2100M
Equipment
Composition
support multi UE
carry out different
tests
simultaneously
Physical connection
Equipment bag
easy to carry and
suitable to be used in
the car
Huawei Dual Mode
Mobile(U626/U636)
![Page 9: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/9.jpg)
9
www.huawei.com Huawei confidential, 2007-10
9
DT Operation Flow
1. Probe Installation. HSDPA test need Probe version 1.3 or above; HSUPA
test need Probe version 1.4 or above.
2. Plug Probe dongle.
3. Connect Hardware device to the laptop.
4. Hardware configuration.
5. System Configuration. Set Log mask.
6. Test Plan Configuration.
7. Import engineering parameters, open Map window and import the related
mapinfo file.
8. Open the parameter widows you want to observe, such as RSCP and Ec/Io
in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message,
NAS Message, etc.
9. Start Test, start recording.
10. After the test finished, press "Stop Test“ button.
Notes: If you don't use "Test Plan" to start test automatically, please
"Start Test” first, then start to make call test.
![Page 10: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/10.jpg)
10
www.huawei.com Huawei confidential, 2007-10
10
Probe Interface
Parameter
observation area
Control &
parameter
items
hardware &
system
configuration
HSDPA
parameters
HSUPA
parameters
RRC&NAS
Messages
Throughput
PS service
statistics
![Page 11: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/11.jpg)
11
www.huawei.com Huawei confidential, 2007-10
11
Hardware configuration
PS domain
test must set
Modem port.
Terminals in the following list can support HSDPA test are: Huawei E620
data card , QUALCOMM TM6275 and QUALCOMM TM6280. Huawei
E220 and E6280 will support HSUPA soon.
Configuration Before Test
![Page 12: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/12.jpg)
12
www.huawei.com Huawei confidential, 2007-10
12
Logmask setting
We can make UE report the data we need through Logmask setting.
System Configuration Before Test
![Page 13: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/13.jpg)
13
www.huawei.com Huawei confidential, 2007-10
13
System Configuration Before Test
Event setting
We can define the event we need throuth Event setting.
![Page 14: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/14.jpg)
14
www.huawei.com Huawei confidential, 2007-10
14
System Configuration Before Test
Alarm setting
We can define the alarm event we need through Alarm setting.
![Page 15: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/15.jpg)
15
www.huawei.com Huawei confidential, 2007-10
15
System Configuration Before Test
Other setting
We can set the Time Record Mode for a Log Packet, GPS synchronization Mode,
DialUp Property for Data Service, Display Filter for Log Data, Replay Mode for
Event and Parameters for DTI Scanner which we need through other setting.
![Page 16: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/16.jpg)
16
www.huawei.com Huawei confidential, 2007-10
16
Test Plan Configuration
Control each device's behavior by selecting Test Plan items and setting property
parameters of each test items. Set the Test Plan respectively for each device
(UE/Scanner).
Test Plan Configuration Before Test
1. Select
Test Device
2. Add Test
Scenario
3. Add
Test Item
4. Set Test
Property
![Page 17: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/17.jpg)
17
www.huawei.com Huawei confidential, 2007-10
17
Set Test Plan for DTI Scanner
1. Select
Test Item
2. Set Item
Property
Test Plan Configuration Before Test
![Page 18: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/18.jpg)
18
www.huawei.com Huawei confidential, 2007-10
18
Set Test Plan for Anritsu Scanner
Test Plan Configuration Before Test
1. Select
Test Item
2. Set Test
Property
![Page 19: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/19.jpg)
19
www.huawei.com Huawei confidential, 2007-10
19
Set Test Plan for Anritsu Scanner(Cont.)
Test Plan Configuration Before Test
Unspecified base station measurement :
Set the common properties of test
Items in the unspecified base station measurement
![Page 20: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/20.jpg)
20
www.huawei.com Huawei confidential, 2007-10
20
Set Test Plan for Anritsu Scanner(Cont.)
Test Plan Configuration Before Test
Unspecified base station measurement :
Set the common properties of test
Items in the Conditions base station
![Page 21: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/21.jpg)
21
www.huawei.com Huawei confidential, 2007-10
21
Set Test Plan for Anritsu Scanner(Cont.)
Test Plan Configuration Before Test
Unspecified base station measurement :
Set the common properties of test
Items in the CH limits
![Page 22: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/22.jpg)
22
www.huawei.com Huawei confidential, 2007-10
22
Set Test Plan for Anritsu Scanner(Cont.)
Test Plan Configuration Before Test
Unspecified base station measurement :
Set the common properties of test
Elements in the MeasureChannel Dialog Box
![Page 23: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/23.jpg)
23
www.huawei.com Huawei confidential, 2007-10
23
Set Test Plan for Anritsu Scanner(Cont.)
Test Plan Configuration Before Test
Specified base station measurement :
Set the specified properties of test
![Page 24: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/24.jpg)
24
www.huawei.com Huawei confidential, 2007-10
24
Set Test Plan for UE
1. Voice call
Test Plan Configuration Before Test
Suggestion: When testing voice call, do not perform PS dialup on the Modem of the
outgoing UE manually. Otherwise, voice call maybe hangs up abnormally.
The UE that is performing PS services can serve as an incoming UE for Voice Call
or Video Phone test. Thus, the CS and PS concurrent test can be performed on the
same UE.
![Page 25: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/25.jpg)
25
www.huawei.com Huawei confidential, 2007-10
25
Test Plan Configuration Before Test
Parameters for Voice Call:
1.1 Call type
Continuous Call: The call continues if it does not fail, drop, or hang up. If the call fails,
drops, or hangs up, Probe waits for a call interval to originate another call.
Call by Call: call: The call lasts and waits for the predetermined calling duration and call
interval, and repeats for the times defined in call count.
1.2 Setup time: the maximum time for call setup. If the call cannot be setup
within the defined period, the call setup fails.
1.3 Calling duration: the duration of one call, from call setup to call normal
release. (apply only to call by call)
1.4 Call interval: the time between two calls, from the previous call disconnection
to the beginning of the next call.
1.5 Exceptional Interval :The interval between the exceptional end of a call drop
and the beginning of the next call.
1.6 Count Mode: the limitations on the call number -> Finite / Infinite.
![Page 26: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/26.jpg)
26
www.huawei.com Huawei confidential, 2007-10
26
Set Test Plan for UE
2. Video Phone
Test Plan Configuration Before Test
Suggestion: To conduct this test, the UE and the called terminal must support
the video calls.
![Page 27: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/27.jpg)
27
www.huawei.com Huawei confidential, 2007-10
27
Set Test Plan for UE
3. PING
Test Plan Configuration Before Test
Note: PING packet size have an effect on PING delay time. Usually, the PING packet
size is described in the criterion of the test project, set the parameter according to the
criterion. Otherwise we can use the default setting: 32 Bytes if there is no special
requirement.
![Page 28: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/28.jpg)
28
www.huawei.com Huawei confidential, 2007-10
28
Parameters for PING:
Test Plan Configuration Before Test
![Page 29: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/29.jpg)
29
www.huawei.com Huawei confidential, 2007-10
29
Set Test Plan for UE
4. Ftp Upload / Ftp Download
Test Plan Configuration Before Test
Note: PS connection can be set up by one FTP Download test item if correct
APN has been set in UE.
![Page 30: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/30.jpg)
30
www.huawei.com Huawei confidential, 2007-10
30
Parameters for Ftp Upload / Ftp Download:
Test Plan Configuration Before Test
4.1 User, Password: FTP user name and password. For anonymous login, also
need to input “anonymous” as username.
4.2 Remote File: Destination file address, input the detailed download path, such
as, ftp://10.0.0.1/download/1.dat
4.3 Local File: Local path to save the download file, such as, C:\1.dat
4.4 MultiTask Count: When we use multi-threading download, set the number of
threads here.
4.5 Test Interval (sec): The time interval between multi downloads. After finishing
a download, wait for serveral time, then start another time’s download.
4.6 FTP Count: the total number of ftp download test.
![Page 31: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/31.jpg)
31
www.huawei.com Huawei confidential, 2007-10
31
Parameters for Ftp Upload / Ftp Download:
Test Plan Configuration Before Test
4.7 Disconnection Mode: the mode of Disconnection, there are three choices:
Keep Disconnected: Do not perform PDP context deactivation ( remain RRC
connection) after the target files are loaded completely, just wait for interval time
then continue next ftp download test.
Disconnect By Time: Perform PDP context deactivation periodically. The period for
the PDP context deactivation is represented by the Valid FTP Duration parameter. If
the target files are not loaded completely within the predefined time, the loading
result shows timeout. Probe considers this loading as failure and initiates another
PDP context deactivation in the next loading.
Disconnect After Transfer Complete: Each time when the file load is complete, PDP
context deactivation would be performed.
FTP Upload:
Parameters are the same with FTP download’s. Probe will upload the local file to
the destination path automatically.
Make sure you have the authority to upload file before test.
![Page 32: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/32.jpg)
32
www.huawei.com Huawei confidential, 2007-10
32
Set Test Plan for UE
5. HTTP
Test Plan Configuration Before Test
![Page 33: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/33.jpg)
33
www.huawei.com Huawei confidential, 2007-10
33
Parameters for HTTP:
5.1 URL:Refers to the destination HTTP address of the server.
5.2 Port:Refers to the HTTP serving port. By default, the value is 80.
5.3 Control Mode:Test by time and Test by RRC state.
5.4 Test Interval :Refers to the interval between two HTTP tests. This
parameter takes effect when Control Mode is Test by Count.
5.5 HTTP Count:Refers to the total number of HTTP tests. This parameter
takes effect when Control Mode is Test by Count.
Test Plan Configuration Before Test
![Page 34: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/34.jpg)
34
www.huawei.com Huawei confidential, 2007-10
34
Set Test Plan for UE
6. PDP
Test Plan Configuration Before Test
Note:If False is selected in Auto Dialup, the connections on the signaling plane are
set up. The signaling includes RRC signaling, PDP context activation request, and PDP
context activation receive message. The service plane, however, is not established. In
such a situation, the PING service is not being connected.
If True is selected, the connections on both signaling and service planes are
established. That is, the PC <-> UE <-> CN channel is set up for dialup connection and
providing services.
![Page 35: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/35.jpg)
35
www.huawei.com Huawei confidential, 2007-10
35
Parameters for PDP:
Test Plan Configuration Before Test
Auto Dialup: If the option is false, then only setup signaling plane connection. In
NAS Message window, we can see the Activate PDP context request &
Activate PDP context accept message, but we can’t perform service in this
mode. If the option is true, then there will setup a connection between PC<--
>UE<-->CN, the same as PS Dialup, we can perform service in this mode.
Reserved Duration: The period when the PDP is in active status, thus, it is time
from activate PDP context accept to deactivate PDP context request.
Test Interval: If a PDP test is success, wait for Test Interval to do next PDP test.
Then, it is time from deactivate PDP context accept to activate PDP context
request.
Exceptional Interval: If a PDP test is failed, wait for Exceptional Interval and
then do next PDP Test.
UL/DL Max Rate (Kbps)
UL/DL Guaranteed Rate (Kbps)
![Page 36: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/36.jpg)
36
www.huawei.com Huawei confidential, 2007-10
36
Set Test Plan for UE
7. PS DaiUp / PS HangUp
Test Plan Configuration Before Test
The function of “PS Dialup” is
to setup a PS connection.
![Page 37: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/37.jpg)
37
www.huawei.com Huawei confidential, 2007-10
37
Parameters for PS Dialup:
Test Plan Configuration Before Test
7.1 APN: Access Point Name.
Ask the local PS domain engineer for the access point name. APN is named as
huawei.com or huawei.
7.2 QoS
• Traffic Class
• UL Max V(kbit/s):uplink max rate
• DL Max V(kbit/s):downlink max rate
• UL Guaranteed V(kbit/s):uplink guarantee bit rate
• DL Guaranteed V(kbit/s):downlink guarantee bit rate
Note: For BE service, such as Background Class and Interactive Class, don’t set
the UL & DL Guaranteed V.
The UMTS Specifications specify that BE service has no requirement on
guarantee bit rate. Setting guarantee bit rate may result in PS connection setup
failure for many mobiles do not support the setting.
![Page 38: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/38.jpg)
38
www.huawei.com Huawei confidential, 2007-10
38
Test Plan Configuration Before Test
Supplements about APN, QoS Setting
a) If leave APN, QoS parameters blank
Probe won’t send the associated command to the UE if the parameters mentioned above
is not set, that is the UE’s former setting will be maintained.
b) Methods for setting APN、QoS and their correlationship
1) Set by AT command in MODEM initial command
2) Set by Probe in Test Plan
When both Probe and MODEM have APN and QoS information, because AT command in
MODEM initial command is send to UE more closely before PS connection setup, it will
replace the information send to UE by Probe. That is Probe’s setting doesn’t work if AT
command also exists in the MODEM initial command.
![Page 39: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/39.jpg)
39
www.huawei.com Huawei confidential, 2007-10
39
Set Test Plan for UE
8. SMS
Test Plan Configuration Before Test
![Page 40: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/40.jpg)
40
www.huawei.com Huawei confidential, 2007-10
40
Parameters for SMS:
8.1 Service Center Number:the number of the short message service center;
8.2 Message:The short message content;
8.3 Destination Number:The destination number of the short message service;
8.4 Test Count:The total number of the cyclic sending;
8.5 Test Interval:Interval between two short messages.
Test Plan Configuration Before Test
![Page 41: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/41.jpg)
41
www.huawei.com Huawei confidential, 2007-10
41
Set Test Plan for UE
9. Video Streaming
Test Plan Configuration Before Test
![Page 42: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/42.jpg)
42
www.huawei.com Huawei confidential, 2007-10
42
Parameters for Video Streaming:
9.1 URL:Refers to the URL address of the destination file, for example,
tsp://192.168.34.154/athens/wuhuan.rm;
9.2 Test Count:the number of the cyclic plays.
Test Plan Configuration Before Test
![Page 43: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/43.jpg)
43
www.huawei.com Huawei confidential, 2007-10
43
Set Test Plan for UE
10. Multi-RAB
Test Plan Configuration Before Test
Note: The Multi-RAB test supports PS and CS concurrent service tests. In
addition, this test provides the solution to the problem of failing to stop AMR
automatic test for the same mobile phone when the dialup connection of data
service is set up.
![Page 44: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/44.jpg)
44
www.huawei.com Huawei confidential, 2007-10
44
Parameters for Multi-RAB:
10.1 Concurrent Type:The type of a concurrent test ;
10.2 Startup Priority:The sequence of sub-services in concurrent tests ;
10.3 FTP Type:FTP Upload / FTP Download;
10.4 End Type:By Time / By File
10.5 Test Count:The counts of test;
10.6 Test Interval:The interval between two tests;
10.7 FTP Retry Count:the maximum retry times after the FTP connection fails ;
Test Plan Configuration Before Test
![Page 45: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/45.jpg)
45
www.huawei.com Huawei confidential, 2007-10
45
Parameters for Multi-RAB(Cont.):
10.8 FTP Time:the time for one FTP transmission ; This parameter takes
effect when End Type is set By Time;
10.9 CS and Ftp Interval:the period between initiation of a call and
execution of FTP service ;
10.10 Traffic Class:Background、Conversational、Interactive、Streaming、
Subscribed;
10.11 UL / DL Max Rate (Kbps);
10.12 UL / DL Max Guaranteed Rate (Kbps).
Test Plan Configuration Before Test
![Page 46: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/46.jpg)
46
www.huawei.com Huawei confidential, 2007-10
46
Set Test Plan for UE
11. Key-Emul
Test Plan Configuration Before Test
Note:Not all functions of a mobile phone can be tested by executing commands.
For the functions such as VP calling, MMS, and E-Mail, you can conduct
automatic dialing test through the key emulation.
![Page 47: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/47.jpg)
47
www.huawei.com Huawei confidential, 2007-10
47
Parameters for Key-Emul:
11.1 Key Emulation List;
11.2 Test Interval ;
11.3 Test Count;
Test Plan Configuration Before Test
![Page 48: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/48.jpg)
48
www.huawei.com Huawei confidential, 2007-10
48
Parameters for Key-Emul(Cont.):
Test Plan Configuration Before Test
![Page 49: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/49.jpg)
49
www.huawei.com Huawei confidential, 2007-10
49
Parameters for Key-Emul(Cont.):
Test Plan Configuration Before Test
![Page 50: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/50.jpg)
50
www.huawei.com Huawei confidential, 2007-10
50
Set Test Plan for UE
12. Wait
Test Plan Configuration Before Test
Note:The Wait test is used to set the time interval between two test items.
![Page 51: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/51.jpg)
51
www.huawei.com Huawei confidential, 2007-10
51
Set Test Plan for UE
13. AT Control
Test Plan Configuration Before Test
Note:Test the AT commands on each UE before the AT control test, because the AT commands and their formats supported by different vendor differ in many ways.
![Page 52: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/52.jpg)
52
www.huawei.com Huawei confidential, 2007-10
52
Parameters for AT Control:
13.1 Test Count:The number of the test;
13.2 Command Edition:Right-click the button on the right side to set the test
commands in the AT Command Edit dialog box, can set test groups and add
test commands for each test group.
Test Plan Configuration Before Test
![Page 53: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/53.jpg)
53
www.huawei.com Huawei confidential, 2007-10
53
Parameters for AT Control(Cont.):
Test Plan Configuration Before Test
![Page 54: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/54.jpg)
54
www.huawei.com Huawei confidential, 2007-10
54
Set Test Plan for UE
14. Stop Test
Test Plan Configuration Before Test
Finish the test
![Page 55: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/55.jpg)
55
www.huawei.com Huawei confidential, 2007-10
55
Common used windows for HSDPA & R99
1. Serving, Active Set & Neighboring Cells
Parameter Window
•Display PSC, RSCP, Ec/Io for
active set, monitor set and detective
set
•In the figure, rectangle legend
implicates active set data, circle
implicates monitor set data, and
triangle implicates detected set data.
The data of the same type is
distinguished from each other with
different colors. Move the mouse to
a place to get the scrambling code
of the current point.
•When the UE is in idle state, PSC
in active set is about the cell where
the UE resides.
![Page 56: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/56.jpg)
56
www.huawei.com Huawei confidential, 2007-10
56
Common used windows for HSDPA & R99
2. Power Control
Parameter Window
DL SIR, SIR
Target
Rx: UE received
power;
Tx: UE tx power
UL/DL transmit
power control
![Page 57: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/57.jpg)
57
www.huawei.com Huawei confidential, 2007-10
57
Common used windows for HSDPA & R99
3. WCDMA BLER
Parameter Window
Displays BLER of different
transport channels.
In HSDPA connection mode,
A-DPCH's DL BLER is being
displayed.
![Page 58: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/58.jpg)
58
www.huawei.com Huawei confidential, 2007-10
58
MAC/RLC Messages
The MAC/RLC Messages window displays the messages about Media Access
Control (MAC) and Radio Link Control (RLC). The messages are visible only when
the associated items in LogMask are selected.
Parameter Window
![Page 59: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/59.jpg)
59
www.huawei.com Huawei confidential, 2007-10
59
RRC Messages
All the UEs or single UE are displayed on the window. The messages selected on
the left navigation tree are displayed. The detailed information is displayed by
double-clicking on the message.
Parameter Window
![Page 60: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/60.jpg)
60
www.huawei.com Huawei confidential, 2007-10
60
GSM RR Messages
The GSM RR Messages window displays GSM radio resource messages. You
can observe GSM RR Messages when UE is in GSM mode.
Parameter Window
![Page 61: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/61.jpg)
61
www.huawei.com Huawei confidential, 2007-10
61
NAS Messages
Whatever mode UE is in, WCDMA, HSDPA or GSM, all the NAS messages
are displayed here as follow:
Parameter Window
![Page 62: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/62.jpg)
62
www.huawei.com Huawei confidential, 2007-10
62
App Throughput
Display both UL and DL application layer data rate, NAS rate and TCP
retransmission rate.
Parameter Window
![Page 63: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/63.jpg)
63
www.huawei.com Huawei confidential, 2007-10
63
RLC Throughput
Display both UL and DL RLC layer throughput, UL PDU retransmission ratio
and DL PDU error ratio.
Parameter Window
![Page 64: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/64.jpg)
64
www.huawei.com Huawei confidential, 2007-10
64
PING Service Quality Evaluation
The PING Service Quality Evaluation window displays the associated
indicators on the user plane of the PING service which includes PING time,
QoS, etc.
Service statistics Chart
![Page 65: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/65.jpg)
65
www.huawei.com Huawei confidential, 2007-10
65
PS Common Indicators
Including attach success rate, attach time, PDP activation success rate,
PDP activation time are displayed here.
Service statistics Chart
![Page 66: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/66.jpg)
66
www.huawei.com Huawei confidential, 2007-10
66
FTP Service Quality Evaluation
Displays the associated indicators on the user plane of the FTP service, including
Login time, download time, download rate, etc.
Service statistics Chart
![Page 67: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/67.jpg)
67
www.huawei.com Huawei confidential, 2007-10
67
HTTP Service Quality Evaluation
Displays the associated indicators on the user plane of the HTTP service, such
as page access time, page download time and page down load rate, etc.
Service statistics Chart
![Page 68: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/68.jpg)
68
www.huawei.com Huawei confidential, 2007-10
68
Contents
GENEX Overview
GENEX Probe General workflow
Using Probe for HSDPA / HSUPA DT data collection
Other Features
Case Study
![Page 69: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/69.jpg)
69
www.huawei.com Huawei confidential, 2007-10
69
HSDPA Parameters window
1. HSDPA Physical Channel Window
Parameter Window
![Page 70: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/70.jpg)
70
www.huawei.com Huawei confidential, 2007-10
70
HSDPA Parameters window
1. HSDPA Physical Channel Window (cont.)
Parameter Window
![Page 71: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/71.jpg)
71
www.huawei.com Huawei confidential, 2007-10
71
HSDPA Parameters window
2. HSDPA Decoding Statistics
Parameter Window
![Page 72: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/72.jpg)
72
www.huawei.com Huawei confidential, 2007-10
72
HSDPA Parameters window
3. HSDPA Link Statistic
Parameter Window
![Page 73: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/73.jpg)
73
www.huawei.com Huawei confidential, 2007-10
73
HSDPA Parameters window
3. HSDPA Link Statistic (cont.)
Parameter Window
Item Description
Scheduled Rate-Delta Instantaneous rate that the MAC layer schedules
Scheduled Rate-Average Average rate that the MAC layer schedules
Served Rate-DeltaInstantaneous rate at which the MAC layer transmits.
The transmission here includes Transmission failure and Re-transmission
Served Rate-AverageAverage rate at which the MAC layer transmits.
The transmission here includes: Transmission failure and Re-transmission
MAC Layer Rate-DeltaInstantaneous rate at which the MAC layer transmits.
The transmission here excludes: Transmission failure and Re-transmission
MAC Layer Rate-AverageAverage rate at which the MAC layer transmits.
The transmission here excludes: Transmission failure and Re-transmission
HS-SCCH Success Rate-
DeltaInstantaneous success rate of the HS-SCCH channel
HS-SCCH Success Rate-
AverageAverage success rate of the HS-SCCH channel
![Page 74: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/74.jpg)
74
www.huawei.com Huawei confidential, 2007-10
74
HSDPA Parameters window
3. HSDPA Link Statistic (cont.)
Parameter Window
![Page 75: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/75.jpg)
75
www.huawei.com Huawei confidential, 2007-10
75
Supplement for HSDPA Link Statistic:
Parameter Window
1. Delta vs AverageDelta is the average value in 200ms.
Average is the average value from the beginning of stat. to the current time. You can choose to clear
the former stat. data. The values displayed by Assistant are all belong to Delta series.
2. Parameters about rateScheduled Rate = The total block size scheduled to the UE during stat. time / (Total time slot
scheduled to the UE * 2ms)
Served Rate = The total block size scheduled to the UE during stat. time / stat. time length
HS-SCCH Success Rate = time slot number scheduled to the UE during stat. time / total time slot
number during stat. time
When multi UEs share a HS-SCCH channel, they will share channel resource. So, HS-SCCH Success
Rate reflects the time ratio of a UE occupies HSDPA resource. The closer to 100% of total HS-SCCH
Success Rate from UEs who share a HS-SCCH channel, the better schedule performance the system
has.
Served Rate = Scheduled Rate * HS-SCCH Success Rate
Mac Layer Rate = Served Rate * (1- SBLER)
![Page 76: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/76.jpg)
76
www.huawei.com Huawei confidential, 2007-10
76
Supplement for HSDPA Link Statistic:
Parameter Window
3. IBLER, SBLER vs Res.BLER
IBLER is 1st MAC-hs error block /total 1st MAC-hs transmission blocks. IBLER
Target can be configured on NodeB. And it’s statistic value in Probe is 1st SBLER
in HSDPA Decoding Statistic Window.
SBLER is MAC-hs error block / total MAC-hs transmission blocks, IBLER target
configured on NodeB have an effect on SBLER, now the common value range of
SBLER is 10%~15%.
Res.BLER means remain BLER, which is within RLC layer. One transmission
block only after multi-times’ unsuccessful MAC-hs retransmission, will be
calculated as RLC layer error block, stat. to Res.BLER. Res.BLER is approximate
to 0 in normal instance.
![Page 77: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/77.jpg)
77
www.huawei.com Huawei confidential, 2007-10
77
Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration
![Page 78: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/78.jpg)
78
www.huawei.com Huawei confidential, 2007-10
78
Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)
![Page 79: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/79.jpg)
79
www.huawei.com Huawei confidential, 2007-10
79
Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)
![Page 80: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/80.jpg)
80
www.huawei.com Huawei confidential, 2007-10
80
Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)
![Page 81: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/81.jpg)
81
www.huawei.com Huawei confidential, 2007-10
81
HSUPA Parameter Window
2. HSUPA UL Channel Configuration
Parameter Window
![Page 82: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/82.jpg)
82
www.huawei.com Huawei confidential, 2007-10
82
Parameter Window
HSUPA Parameter Window
3. HSUPA Link Statistics
![Page 83: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/83.jpg)
83
www.huawei.com Huawei confidential, 2007-10
83
HSUPA Parameter Window
3. HSUPA Link Statistics(Cont.)
Parameter Window
![Page 84: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/84.jpg)
84
www.huawei.com Huawei confidential, 2007-10
84
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data Collection
Other Features
Case Study
![Page 85: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/85.jpg)
85
www.huawei.com Huawei confidential, 2007-10
85
2G/3G re-selection and handover test
WCDMA window
Synchronous decoding of 2G/3G
messages
2G/3G power information and cell
information
Events can be displayed in various
modes
2G/3G re-selection and handover test
GSM window
Customized window
Check handover time in
event window
![Page 86: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/86.jpg)
86
www.huawei.com Huawei confidential, 2007-10
86
Scanner test
Top N Pilot test
Top N pilot test
Specified pilot test
Spectrum analysis
Multi-frequency scanning
Multi-path signal analysis
CW test
Professional Scanner test
Spectrum test
Multi-path signal analysis
Multi-frequency
test
![Page 87: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/87.jpg)
87
www.huawei.com Huawei confidential, 2007-10
87
Walking test
Indoor test
Support indoor test
Vertical test
Walking test
• Automatic
• Manual
Vertical test
![Page 88: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/88.jpg)
88
www.huawei.com Huawei confidential, 2007-10
88
Rich and comprehensive predefined
events, for example, call setup, call drop,
handover and so on
Data service analysis events
2G/3G handover events
Events displayed on graphs and maps
Co-Activation of event, signaling data and
measurement data facilitates problem
location
Customized event icons and alert tones
Events auto-detection
Handover
Complete
Attention!
Call Drop!!
![Page 89: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/89.jpg)
89
www.huawei.com Huawei confidential, 2007-10
89
Loading log files as a navigation
of test
Multi-layers display on map, and
user can set offset to any one
Supports SC reuse scene
Friendly interface of drive-testing
Layer offset
Enhanced map display
Event and track preview
![Page 90: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/90.jpg)
90
www.huawei.com Huawei confidential, 2007-10
90
Project Template
Project Template
Site Verification
Optimize
Benchmark
Acceptance
Customize
The Probe supports customizing and
loading project templates. All the project
templates are stored in the sub-folder of
the Template Project folder. When the
Probe is being installed, the following
default folders of different categories are
generated.
You can also set custom project
templates and save them in the directory.
When multiple tests with a similar function
are being performed, you can directly
open the corresponding project template
but need not carry out repeated project
settings.
![Page 91: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/91.jpg)
91
www.huawei.com Huawei confidential, 2007-10
91
Log file replay
1. Parameter Window layout
2. Open log file
3. Set play speed
4. Play log file
Route and event preview
Logfile playing, multi-window co-activation
5. Locate event
![Page 92: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/92.jpg)
92
www.huawei.com Huawei confidential, 2007-10
92
Basic procedure of Probe data export
Export Data
1. select Export data 2. select target format3. set source file, destination
file and data range
4. select device and
Log item to export
5. start export
•Bin
•Text
•QXDM (Qualcomm data format)
•Excel
Data Format
* Exported data used for post-processing of CW
Measurements data, data geographic binning and
filter.
![Page 93: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/93.jpg)
93
www.huawei.com Huawei confidential, 2007-10
93
Setting an Auto View
Setting an Auto View Funtion
You can open the configured window or page by selecting a button on the toolbar.
![Page 94: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/94.jpg)
94
www.huawei.com Huawei confidential, 2007-10
94
The Auto View Config dialog box consists of five tab pages that share the Auto
open and arrange control. If you select the Auto open and arrange check box,
the system creates the configured page and the page view configured in the
page after the auto view is configured.
UE Common
UE Overview
UE Service Stat.
DTI Scanner
Anritsu Scanner
Setting an Auto View
Setting an Auto View Funtion
![Page 95: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/95.jpg)
95
www.huawei.com Huawei confidential, 2007-10
95
Setting an Auto View
UE Common
1. Page Name:
Default Setting:
Messages;
2. Page View:
Select the
needed View
Window.
![Page 96: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/96.jpg)
96
www.huawei.com Huawei confidential, 2007-10
96
Setting an Auto View
UE Overview
1. Set the view and
page name for
every UE under
test on this tab.
This type of
view is
irrespective of
the test plan
configuration.
![Page 97: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/97.jpg)
97
www.huawei.com Huawei confidential, 2007-10
97
Setting an Auto View
UE Service Stat.
![Page 98: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/98.jpg)
98
www.huawei.com Huawei confidential, 2007-10
98
Setting an Auto View
UE Service Stat.
![Page 99: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/99.jpg)
99
www.huawei.com Huawei confidential, 2007-10
99
DTI Scanner
• Page Name:
Default Setting is
DTI Pilot scan;
Every test Item
has a default
View.
Setting an Auto View
![Page 100: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/100.jpg)
100
www.huawei.com Huawei confidential, 2007-10
100
Anritsu Scanner
1. You can set the
view and page
name for testing
Anritsu Scanner on
this tab. This type of
view is irrespective
of the test plan
configuration.
2. By default, the
Page Name is set
to Anritsu Pilot
scan and each test
item has its
corresponding view.
Setting an Auto View
![Page 101: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/101.jpg)
101
www.huawei.com Huawei confidential, 2007-10
101
Convenient View
On the left of the soft, include five Page: Project、Control、Configuration、View、
Property.
Navigation View
![Page 102: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/102.jpg)
102
www.huawei.com Huawei confidential, 2007-10
102
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data Collection
Other Features
Case Study
![Page 103: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/103.jpg)
103
www.huawei.com Huawei confidential, 2007-10
103
Contents
Case1. Inter-RAT handover test
Case2. WCDMA inter-frequency handover test
Case3. Multi-frequency Scanning
![Page 104: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/104.jpg)
104
www.huawei.com Huawei confidential, 2007-10
104
Case1. Inter-RAT handover test
Inter-RAT handover test
Event observation — Location of handover point
![Page 105: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/105.jpg)
105
www.huawei.com Huawei confidential, 2007-10
105
Case1. Inter-RAT handover test
Messages and measurement
from different networks
Inter-RAT handover
Time of Handover
signaling
![Page 106: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/106.jpg)
106
www.huawei.com Huawei confidential, 2007-10
106
Case2. WCDMA inter-frequency handover
test
The signal frequency in
active set is 2137.40
when the test starts
WCDMA inter-frequency handover
Log file:
Signaling window
![Page 107: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/107.jpg)
107
www.huawei.com Huawei confidential, 2007-10
107
Case2. WCDMA inter-frequency handover
test
Signaling
observation before
handover
WCDMA inter-frequency handover process
![Page 108: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/108.jpg)
108
www.huawei.com Huawei confidential, 2007-10
108
Case2. WCDMA inter-frequency handover
test
Observe it again, and the
frequency handover to 2132.40
WCDMA inter-frequency handover process
![Page 109: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/109.jpg)
109
www.huawei.com Huawei confidential, 2007-10
109
Case3. Multi-frequency Scanning
1. Set multi-frequency
Simultaneous scanning of multi-
frequency2. Scanned multi-
frequency
3. Select specified
frequency to observe it
![Page 110: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/110.jpg)
110
www.huawei.com Huawei confidential, 2007-10
110
Case3. Multi-frequency Scanning
Simultaneous observation
of different frequencies
Simultaneous scanning of multi-frequency
![Page 111: 09 Introduction to GENEX Probe (Ver1.4)](https://reader035.vdocument.in/reader035/viewer/2022081716/551141bf4a7959e5028b45cc/html5/thumbnails/111.jpg)
www.huawei.com Huawei confidential, 2007-10