Download - Document12

Transcript
Page 1: Document12

Work Order

Work Order NO : 000012 Work Trade :Mechanical

Work Order Status : Closed Work Type : corrective

Work priority : Emergency

Assigned to : FET Collage Received by : ibraheem khress Requester : Dr khaleel Abu shgair Received Data/Time : Phone Number :

PM Target Start Data : PM Target End Data :

Problem Description : Problem in Motion and Spindle Rotation

Note to Technician : small error on dimensions show up

Failure Code : 1 Check list No:

Asset No : 1,2,3,4 Location NO : 2

Asset Name : Fagor Turning Location Name : CNC LAB

Case description Action Taken Prevention Taken

Part and labor Details

**D=Direct Issue , I = Inventory

Data and Time work was started Data : Time :

Data and Time work was completed Data : Time :

Certification and Work Completion Name and Signature of Technician/Engineer Name and Signature of Requester/Supervisor

………………Name ………………Signature Data : Time :

………………Name ………………Signature Data : Time :

Please rate our services :

1-Poor 2-Fair 3-Good 4-Very Good 5-Excellent

Temperature fluctuates as the part is machined

Stabilize the temperature of the blank by providing enough coolant while machining.

Page 2: Document12

Work Order

Work Order NO : 000012 Work Trade :Mechanical

Work Order Status : Open Work Type : Prevention

Work priority : Normal

PM checklist

Checklist No : 4

Checklist Desc:

1- Check spindle belts 2- Check spindle temperature and adjust chiller card 3- Check chiller system and adjust, and clean pump filter, fill if necessary 4- Check drawbar for proper retention and pressure at tool in/out 5- Check and adjust spindle tram 6- Change Spindle Motor filter if applicable 