Transcript
Page 1: AutoAuto IIA500A500 IA500.pdf · 0.1-2.5 g/L 0.27-2.60 g/L 0.28-4.10 g/L ALB PAB ApoA1 Apo B AT3 D-Dimer Lp(a) 5-124 g/L 0.04-1.34 g/L 0.24-4.10 g/L 0.24-5.20 g/L 0.06-0.75 g/L 0.28-15.70

Features

Throughput: l00 tests/hour26 positions for samples30 positions for reagentsAuto identification of reagents by RFID technologyOn-board reagent coolingProbe with liquid level detection and collision protection automatic Antigen Excess detectionroad test menu, more than 35 assays available onDesktop PC along with analyzer

Auto IA500Auto IA500

System Description

MethodsOperative ModeThroughputSample PositionSample Containers

Sampling

Minimum Reaction Volume:Reagents

ControlReaction CuvettesReaction TemperatureOptic ModuleOptional AccessoriesPower RequirementsDimensions and Weight

Operating Environment Requirements

Control UnitConnection

Designed for clinical laboratories, Auto IA 500 is a random access bench top, fully automated immuno-Nephelometry SystemFixed time immunonephelometryBatch, random, STATUp to 100 tests/hour26 positions STAT sample availablePrimary tubes (diameter from 8 to 16mm ; height up to 100mm), Cups of different sizesSample volume: 6uL-20uL (1µL inr)Automatic sample probe washing (internal and external)Probe wash cycle is operator-programmable230µL30 positions available for reagent, Auto Reagent Identification , Reagent disk with non-stop cooling functionsAuto drawing of control Levey-Jennings and Westguard QC chart50 disposable , optic grade cuvettesConstantly and precisely monitored (37°C + 0.1)Laser 670 nm 1mWPrinter, Barcode reader100-240VA C, 50/60 Hz60 x 55 x 65cm (H x W x L)Weight: 60kgRoom temperature: 18-32°CRelative humidity: 30-85%Smart information management system with mass data storageCan be connected to LIS by Protocol HL7

Page 2: AutoAuto IIA500A500 IA500.pdf · 0.1-2.5 g/L 0.27-2.60 g/L 0.28-4.10 g/L ALB PAB ApoA1 Apo B AT3 D-Dimer Lp(a) 5-124 g/L 0.04-1.34 g/L 0.24-4.10 g/L 0.24-5.20 g/L 0.06-0.75 g/L 0.28-15.70

Intelligent Software

Intuitive operator interfaceQuick view of real-time running statusLevey-Jennings QC chartsSTAT programming

Reagent tray

30 positions for reagentReagent disk with non-stop cooling functions Reagent can be auto-identified by RFID technology Ready to use, liquid reagent

Carefree Cleaning SystemProbe can be washed by external-inter-nal way

Smart Pipetting System3D transferring armProbe with liquid level detection and collision protectionAuto tracking of reagent residual to ensure the continuity of analysis

Precise Dispensing SystemTeflon piston technology, longer duration Dispensing CV% < 1%

Auto-IA5001

2

34

Sample tray

26 sample positions. Both standard blood collection tube and centrifuge tube can be placed in sample disk STAT samples can be inserted and it's prior to routine samples

Assays availableAssay

Immune Disease

Accute Phase Protein

Linear range

Cardiovascular Disease

Kidney Disease

Diabetes

IgAIgGIgMC3C4ASORF C1 IN KAPLAM

bCRPUsCRPCRPSAAHPTTRFCER AATAAG

0.9-380.0 mg/L0.22-19.00 mg/L1.6-152.0 mg/L3-200 mg/L0.15-3.80 g/L0.25-6.10 g/L0.1-2.5 g/L0.27-2.60 g/L0.28-4.10 g/L

ALBPABApoA1Apo BAT3D-DimerLp(a)

5-124 g/L0.04-1.34 g/L0.24-4.10 g/L0.24-5.20 g/L0.06-0.75 g/L0.28-15.70 mg/L60-1200 mg/L

mALBBMGAMGA1 MIgG U TRFUCys CRBP

9.5-230.0 mg/L0.4-13.0 mg/L0.28-7.20 g/L5-200 mg/L4-100 mg/L1-80 mg/L0.4-7.6 mg/L5-160 mg/L

HbA1c 2.8%-15.5%

0.23-5.10 g/L1.8-26.0 g/L0.18-4.60 g/L0.19-4.70 g/L0.06-2.20 g/L41-607 IU/mL20-306 IU/mL0.05-1.00 g/L0.88-12.20 g/L0.65-7.10 g/L


Top Related