![Page 1: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/1.jpg)
© 2009 PETROLIAM NASIONAL BERHAD (PETRONAS)
All rights reserved. No part of this document may be reproduced, stored in a retrieval system or transmitted in any form or by any means (electronic, mechanical, photocopying, recording or otherwise) without the permission of the copyright owner.
MAKING IT HAPPENMAKING IT HAPPEN
MLNG/PLM/2010/0013PROVISION OF CONDITIONAL ASSESSMENT & REMAINING LIFE ANALYSIS FOR MODULE 2 BOILERS IN PETRONAS LNG COMPLEX
INTERNAL USE
Presented toBidder’s Site Visit on 17th May 2010ByZamsyari Bin MadhanMLNG
![Page 2: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/2.jpg)
2MAKING IT HAPPENMAKING IT HAPPEN2
1. Objectives
2. General MLNG Boiler Arrangement
3. Scope of Inspections
Appendix I: PhotosAppendix II: Work Specification
Contents
![Page 3: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/3.jpg)
3MAKING IT HAPPENMAKING IT HAPPEN
General MLNG Boiler Arrangement
3
![Page 4: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/4.jpg)
4MAKING IT HAPPENMAKING IT HAPPEN
General MLNG Boiler Arrangement
4
![Page 5: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/5.jpg)
5MAKING IT HAPPENMAKING IT HAPPEN5
To brief the bidder with on MLNG/PLM/2010/0013 Conditional Assessment & Remaining Life Analysis For Module 2 Boilers In PETRONAS LNG Complex.
Objectives
![Page 6: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/6.jpg)
6MAKING IT HAPPENMAKING IT HAPPEN6
Scope Of Inspections
Test Conducted
1 Visual Inspection (VI) 8 Remote Field Electromagnetic Test (RFET)
2 Dye Penetrant Test (DPT) 9 Remote Visual Inspection (RVI)
3 Magnetic Particle Test (MPT) 10 In Situ Metallography (IM)
4 Ultrasonic Flaw Detection (UFD) 11 Hardness Testing (HT)
5 Ultrasonic Thickness Measurement (UTM) 12 Dimensional Measurement (DM)
6 Non Destructive Oxide Thickness Inspection (NOTI) 13 Metallographic Replication (MR)
7 Non Destructive Hydrogen Damage Inspection (NDHDI) 14 Deposit Collection (DC)
![Page 7: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/7.jpg)
7MAKING IT HAPPENMAKING IT HAPPEN
Scope Of Inspections
7
DC &DM
Drums, Stack
DPT Drums, Headers & All weld joints
MPT Drums, Headers & all weld joints
UFD Headers , Drums
UTM Headers , Drums & Stack, MSL, PSH & SSH, DSH
NOTI PSH & SSH tubes
NDHDI Furnace wall tubes
RFET Boiler bank tubes, Furnace wall tubes
RVI Headers & Drums
IM Furnace wall tubes, PSH&SSH tubes
HT Headers, Drums & MSL
DM Headers, Drums & MSL, All tubes
MR Furnace wall tubes, PSH & SSH tubes
VI All pressured parts, insulation , Structure & Drums Supports
![Page 8: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/8.jpg)
8MAKING IT HAPPENMAKING IT HAPPEN8
Photos
Visual Inspection (VI)
Mud Drum Steam Drum
![Page 9: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/9.jpg)
9MAKING IT HAPPENMAKING IT HAPPEN9
Photos
Dye Penetrant Test (DPT)
Buckstay Steam Drum
![Page 10: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/10.jpg)
10MAKING IT HAPPENMAKING IT HAPPEN10
Photos
Magnetic Particle Test (MPT)
SSH Header Steam Drum
![Page 11: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/11.jpg)
11MAKING IT HAPPENMAKING IT HAPPEN11
Photos
Ultrasonic Flaw Detection (UFD)
Steam Drum Steam Drum
![Page 12: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/12.jpg)
12MAKING IT HAPPENMAKING IT HAPPEN12
Photos
Non Destructive Oxide Thickness Inspection Service (NOTI)
Primary & Secondary Superheater
![Page 13: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/13.jpg)
13MAKING IT HAPPENMAKING IT HAPPEN13
Photos
Non Destructive Hydrogen Damage Inspection (NDHDI)
![Page 14: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/14.jpg)
14MAKING IT HAPPENMAKING IT HAPPEN14
Photos
Remote Field Electromagnetic Test (RFET)
Steam Drum Steam Drum
![Page 15: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/15.jpg)
15MAKING IT HAPPENMAKING IT HAPPEN15
Photos
Remote Visual Inspection (RVI)
Primary Superheater Header
![Page 16: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/16.jpg)
16MAKING IT HAPPENMAKING IT HAPPEN16
Photos
In Situ Metallography (IM)
Primary Superheater Outlet
![Page 17: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/17.jpg)
17MAKING IT HAPPENMAKING IT HAPPEN17
Photos
Metallographic Replication (MR)
![Page 18: Boiler - Conditional Assesment - Remaining Life Analysist CARLA](https://reader030.vdocument.in/reader030/viewer/2022020713/552701a649795900108b46f6/html5/thumbnails/18.jpg)
18MAKING IT HAPPENMAKING IT HAPPEN18
Thank You