Sandwell MBC
Sandwell Homes
Education
CanVent System
Cooking Equipment
Input & Extract System
Front Entrance
CanVent Wall Mounted Kitchen Canopy
Working closely with Sandwell MBC, Airtherm Engineering have recently
completed the new installation of a kitchen ventilation system, including a
complete control solution that features a thyristor, speed regulators and gas
interlock.
The existing canopy was made of a metal and glass construction which we
removed from site, and a stainless steel wall mounted extraction canopy was
designed and installed in it's place, complete with a provision for tempered
make-up air.
The project had a very tight schedule, however, our expert installation team
ensured the system was fully operational prior to the School kitchen re-
opening on Friday 31st August 2012.Control Solution
-
7/30/2019 Case Study for Tividale Hall Primary School.pdf
2/2
Product Range
Our product range extends from simple condense canopies, extract only, island or wallmounted canopies, through to our air injection island systems allowing both input and
extract. If required, the input air can be pre-heated for additional internal staff
comfort during the cold winter months. All products can be configured to suit each
individual application.
Manufacture
All canopies are manufactured from 304 (En 1.4301) or 316 (En 1.4401) stainless steel
where specified and are suitably braced to prevent product distortion. All joints are
welded and polished.
Our Canopies are cut, punched and folded into sub sections and factory assembled by
means of computer controlled seam welds, and non-visible mechanical fixings.
Systems are manufactured to the strict guidelines of DW/172, British Standards and
conform to HSE for commercial kitchen ventilation. Wall mounted or island canopies
can be manufactured to meet almost any dimension but typically 1000mm to 8000mm
long. The system ductwork is manufactured and installed to incorporate cleaning and
maintenance access doors to fully comply with DW/144 & TR/19 standards.
Allowances:
a) High efficiency stainless steel grease eliminator baffles cells.
b) Grease control system with removable drawers.
c) Factory fitted duct connection collars.
d) Twin fluorescent recessed luminaries manufactured to IP65, steam heat and grease-
proof to provide and average illumination level of 500 lux upon the working plane
below. All pre-wired to junction box situated using heat resistant flex cable.
e) Galvanised ductwork to DW 144 HVCA standards allowing for single wall 0.8mmthk.
f) 2No short cased Elta fans, single phase supply C/w ancillary components & speed
controllers.
g) 20kw heater battery & control system
h) 2No 150mm x 50mm x 2000mm high stainless steel support columns located either
end of unit.
i) 1No 3600mm long x 220mm wide stainless steel rear valance to enclose pipes /
services.
Airtherm Engineering Ltd
Ventilation House
Pedmore
Stoubridge
West Midlands
DY9 0DS
Tel: 0844 8092509
Fax: 01562 887312
xtract Canopy
Grease Filters