Download - Fcsreport Cmfs100m 50 Gpm
7/21/2019 Fcsreport Cmfs100m 50 Gpm
http://slidepdf.com/reader/full/fcsreport-cmfs100m-50-gpm 1/1
Micro Motion Calculation SummaryDate: 08/28/15
Company: -
Project Name: -
Service: Diesel B5
Sensor Model #: CMFS100M
Sensor Tag(s): FE-029
Transmitter Model #: -
Transmitter Tag(s): FQIT-029
Wetted Material: 316L SS
Fluid: Custom: Diesel B5Fluid State: Liquid
Mass Flow Accuracy at Operating Flow (+/- % of Rate): 0.1000
Density Accuracy at all Rates ( +/- ): 0.0020 g/cm3
Pressure Drop at Operating Flow: 12.1250 psi
Sensor Minimum Pressure at operating conditions: 27.1157 psig
Velocity at Operating Flow: 26.7828 ft/sec
Min Operating* Max Design Units
Flow Rate: 4.5000 50.0000 - - USGPM
Pressure: - 41.0000 - - psig
Process Fluid Temperature: - 20.0000 - - C
Ambient Temperature: - 20.0000 - - C
Density: - 0.8700 - - g/cm3
Viscosity: - 4.9000 - - cP Gas Only
Base Reference Temperature: F - Density:
Base Reference Pressure: psia -
Base Reference Density: lb/ft3 -
Process Connection: -
Process Connection Pressure Rating: -
@Temperature: -
Flow Rate USGPMMass Flow
Accuracy +/- % of RatePressure
Drop*psi Velocity* ft/sec Re
50.0000 0.10 12.13 12.13 1327045.4500 0.10 10.14 10.14 12060
40.9000 0.10 8.34 8.34 10850
36.3500 0.10 6.70 6.70 963931.8000 0.10 5.25 5.25 8429
27.2500 0.10 3.99 3.99 721922.7000 0.10 2.93 2.93 600918.1500 0.10 2.05 2.05 4799
13.6000 0.10 1.34 1.34 35899.0500 0.10 0.77 0.77 2380
4.5000 0.10 0.28 0.28 1170
Flow Rate (USGPM)
4 . 5 0 0 0
6 . 3 2 0 0
8 .1 4 0 0
9 . 9 6 0 0
1 1 .7 8 0 0
1 3 . 6 0 0 0
1 5 .4 2 0 0
1 7 .2 4 0 0
1 9 . 0 6 0 0
2 0 . 8 8 0 0
2 2 .7 0 0 0
2 4 . 5 2 0 0
2 6 . 3 4 0 0
2 8 .1 6 0 0
2 9 . 9 8 0 0
3 1 . 8 0 0 0
3 3 . 6 2 0 0
3 5 .4 4 0 0
3 7 .2 6 0 0
3 9 . 0 8 0 0
4 0 . 9 0 0 0
4 2 .7 2 0 0
4 4 . 5 4 0 0
4 6 . 3 6 0 0
4 8 .1 8 0 0
5 0 . 0 0 0 0
F l o
w A
c c u r a c y
-0.12
-0.08
-0.04
0.00
0.04
0.08
0.12 P r e s s ur eD r o p
( p s i )
0
3
6
9
12
15
18
FlowAccuracy
PressureDrop
FlowAccuracy
Sizing Details
*All pressure drop and velocity results are based on the process conditions (except flow rate) that are entered in the Operatingcolumn.
Notes: -
Prepared By:[email protected]
Project ID: 482899
Oracle Version: 11.5.10.2 Application: CT Puerto Maldonado