7/21/2019 Fcsreport Cmfs100m 50 Gpm http://slidepdf.com/reader/full/fcsreport-cmfs100m-50-gpm 1/1 Micro Motion Calculation Summary Date: 08/28/15 Company: - Project Name: - Service: Diesel B5 Sensor Model #: CMFS100M Sensor Tag(s): FE-029 Transmitter Model #: - Transmitter Tag(s): FQIT-029 Wetted Material: 316L SS Fluid: Custom: Diesel B5 Fluid State: Liquid Mass Flow Accuracy at Operating Flow (+/- % of Rate): 0.1000 Density Accuracy at all Rates ( +/- ): 0.0020 g/cm3 Pressure Drop at Operating Flow: 12.1250 psi Sensor Minimum Pressure at operating conditions: 27.1157 psig Velocity at Operating Flow: 26.7828 ft/sec Min Operating* Max Design Units Flow Rate: 4.5000 50.0000 - - USGPM Pressure: - 41.0000 - - psig Process Fluid Temperature: - 20.0000 - - C Ambient Temperature: - 20.0000 - - C Density: - 0.8700 - - g/cm3 Viscosity: - 4.9000 - - cP  Gas Only  Base Reference Temperature: F - Density: Base Reference Pressure: psia - Base Reference Density: lb/ft3 - Process Connection: - Process Connection Pressure Rating: - @Temperature: - Flow Rate USGPM Mass Flow Accuracy +/- % of Rate Pressure Drop* psi Velocity* ft/sec Re 50.0000 0.10 12.13 12.13 13270 45.4500 0.10 10.14 10.14 12060 40.9000 0.10 8.34 8.34 10850 36.3500 0.10 6.70 6.70 9639 31.8000 0.10 5.25 5.25 8429 27.2500 0.10 3.99 3.99 7219 22.7000 0.10 2.93 2.93 6009 18.1500 0.10 2.05 2.05 4799 13.6000 0.10 1.34 1.34 3589 9.0500 0.10 0.77 0.77 2380 4.5000 0.10 0.28 0.28 1170 Flow Rate (USGPM) .  5  0  0  0  6 .  3  0  0  8 .  0  0  9 .  9  6  0  0 .  8  0  0  3 .  6  0  0  0  5 .  0  0 .  0  0  9 .  0  6  0  0  0 .  8  8  0  0 .  0  0  0 .  5  0  0  6 .  3  0  0  8 .  6  0  0  9 .  9  8  0  0  3 .  8  0  0  0  3  3 .  6  0  0  3  5 .  0  0  3 .  6  0  0  3  9 .  0  8  0  0  0 .  9  0  0  0 .  0  0 .  5  0  0  6 .  3  6  0  0  8 .  8  0  0  5  0 .  0  0  0  0    F    l   o   w     A   c   c   u   r   a   c   y -0.12 -0.08 -0.04 0.00 0.04 0.08 0.12   e  s  s  u  e  o  p  (  p  s  ) 0 3 6 9 12 15 18 Flow Accuracy Pressure Drop Flow Accuracy Sizing Details *All pressure drop and velocity results are based on the process conditions (except flow rate) that are entered in the Operating column. Notes: - Prepared By: GGUTIERREZ@INSPECTRA PERU.COM Project ID: 482899 Oracle Version: 11.5.10.2 Application:  CT Puerto Maldonado

Upload: sergio-panta-abad

Post on 05-Mar-2016

221 views

Category:

Documents


0 download

DESCRIPTION

Fcsreport Cmfs100m 50 Gpm

TRANSCRIPT

Page 1: Fcsreport Cmfs100m 50 Gpm

7/21/2019 Fcsreport Cmfs100m 50 Gpm

http://slidepdf.com/reader/full/fcsreport-cmfs100m-50-gpm 1/1

Micro Motion Calculation SummaryDate: 08/28/15

Company: -

Project Name: -

Service: Diesel B5

Sensor Model #: CMFS100M

Sensor Tag(s): FE-029

Transmitter Model #: -

Transmitter Tag(s): FQIT-029

Wetted Material: 316L SS

Fluid: Custom: Diesel B5Fluid State: Liquid

Mass Flow Accuracy at Operating Flow (+/- % of Rate): 0.1000

Density Accuracy at all Rates ( +/- ): 0.0020 g/cm3

Pressure Drop at Operating Flow: 12.1250 psi

Sensor Minimum Pressure at operating conditions: 27.1157 psig

Velocity at Operating Flow: 26.7828 ft/sec

Min Operating* Max Design Units

Flow Rate: 4.5000 50.0000 - - USGPM

Pressure: - 41.0000 - - psig

Process Fluid Temperature: - 20.0000 - - C

Ambient Temperature: - 20.0000 - - C

Density: - 0.8700 - - g/cm3

Viscosity: - 4.9000 - - cP Gas Only 

Base Reference Temperature: F - Density:

Base Reference Pressure: psia -

Base Reference Density: lb/ft3 -

Process Connection: -

Process Connection Pressure Rating: -

@Temperature: -

Flow Rate USGPMMass Flow

Accuracy +/- % of RatePressure

Drop*psi Velocity* ft/sec Re

50.0000 0.10 12.13 12.13 1327045.4500 0.10 10.14 10.14 12060

40.9000 0.10 8.34 8.34 10850

36.3500 0.10 6.70 6.70 963931.8000 0.10 5.25 5.25 8429

27.2500 0.10 3.99 3.99 721922.7000 0.10 2.93 2.93 600918.1500 0.10 2.05 2.05 4799

13.6000 0.10 1.34 1.34 35899.0500 0.10 0.77 0.77 2380

4.5000 0.10 0.28 0.28 1170

Flow Rate (USGPM)

4 . 5  0  0  0 

 6 . 3 2  0  0 

 8 .1 4  0  0 

 9 . 9  6  0  0 

1 1 .7  8  0  0 

1  3 . 6  0  0  0 

1  5 .4 2  0  0 

1 7 .2 4  0  0 

1  9 . 0  6  0  0 

2  0 . 8  8  0  0 

2 2 .7  0  0  0 

2 4 . 5 2  0  0 

2  6 . 3 4  0  0 

2  8 .1  6  0  0 

2  9 . 9  8  0  0 

 3 1 . 8  0  0  0 

 3  3 . 6 2  0  0 

 3  5 .4 4  0  0 

 3 7 .2  6  0  0 

 3  9 . 0  8  0  0 

4  0 . 9  0  0  0 

4 2 .7 2  0  0 

4 4 . 5 4  0  0 

4  6 . 3  6  0  0 

4  8 .1  8  0  0 

 5  0 . 0  0  0  0 

   F   l  o

  w    A

  c  c  u  r  a  c  y

-0.12

-0.08

-0.04

0.00

0.04

0.08

0.12   P r  e s  s  ur  eD r  o p

 (   p s i   )  

0

3

6

9

12

15

18

FlowAccuracy

PressureDrop

FlowAccuracy

Sizing Details

*All pressure drop and velocity results are based on the process conditions (except flow rate) that are entered in the Operatingcolumn.

Notes: -

Prepared By:[email protected]

Project ID: 482899

Oracle Version: 11.5.10.2 Application:  CT Puerto Maldonado