260

FNES LED Series Self-Contained Emergency Lighting with Self-Test SystemZone 2 - 21 and 22

Applications• Providesadequatelightingand/orvisualindicationof

accessandexitroutesduringanevacuationinahazardousenvironment.

• CanbeinstalledinhazardousareasdesignatedasZone2,21and22.

• Typicalapplicationsincludeoilrefineries,petrochemicalplants,pulp,papermillsandsilos.

Features• Powersupply230Vac50/60Hz.• 1hourduration(emergency).• Non-maintained.• Operatesinanyposition.• Batterypack. —Escaperoutelighting:2.4V-1.5Ah(2cells-Nicd).

—Spacelighting:7.2V-2.2Ah(6cells-NiMh).• OpenandcloseusinganAllenkey(size10)ora6mmflat

screwdriver.• Connectiontoplug-interminalblockvia2x5x2.5mm2

terminals.• TwoM20clearanceholessuppliedwithonecablegland(dia.

6.5to14.5mm),oneblankingplugandtwolocknuts.• ChargeindicatorbygreenLED(lifetimeover10years).• Automaticbuilt-inself-testsystem(SATI)withmemorizationof

testsindicatedbyLEDs.• Usingamicroprocessorandaninternalclock,theunitwillcarry

outautomatictests.• Weeklytest:Lampcheckduration6seconds.• Quarterlytest:Emergencyoperationandlampcheckfor1hour.• Canberemotelycontrolledandcheckedwithoutswitching

themainsoffwithremotecontrolunitfromLegrand(CatalogNumber03901)orURA(CatalogNumber095448and095450)manufacturers.

• Theremotecontrolunitinstalledinasafeareaorinsideaflameproofboxallowsmanualignitionofalltheunits(max.300units)forvisualinspectionoftheiroperation.

• Escaperoutelighting:55lumens,0.50wattage.• Spacelighting:540lumens,0.95wattage.

Standard Materials• Body:fiberglassreinforcedpolyester• Diffuser(hingedtobody):polycarbonate• Gasket:elastomer• Fixingbrackets:zincplatedsteel,graypaintedaluminumor316

stainlesssteel• Cableglandandblankingplug:polyamide• Locknut:nickel-platedbrass

Options• Addressableversions:

—Providingtheregulatorycontroloftheemergencylightingunitsandcentralizinginformationcomingfromthoseunitsonacomputerizedmanagementsystem.

—Operatingwithoutanyspecialline,communicationbetweenunitsandthecontrolsystemisrealizedviamains-bornesignalsontheremotecontrolline.

—Capacity:onecontrolsystemfor200emergencylightingunits.—Max.capacity:1000emergencylightingunitswithboosters.

• Addressablemonitoringsoftware,pleaseconsultfactory.• Lowtemperatureapplication,pleaseconsultfactory.

Certifications and Compliances• CertificationType:FLn• Zone2 —ConformingtoATEX94/9/CE:CE0081 II3G —ATEX/IECProtection:ExnRII —TRating:T6• Zone21-22 —ConformingtoATEX94/9/CE:CE0081 II2D —ATEX/IECProtection:ExtDA21andExtDA22 —SurfaceTemperature:T167°F/T75°C• AmbientTemperature:-40°F/-40°Cto131°F/55°C• CEDeclarationofConformity:50212(Zone2-22)and50227

(Zone21)• ATEXCertificate:LCIE03ATEX6072(Zone2-22),LCIE02ATEX

6067(Zone21)• IECExCertificate:IECExLCI04.0021(Zone2-22)• OtherCertifications:GOST• IndexofProtection(solidandliquid):IP66/67• ImpactResistance(shock):IK10• Exstandards:EN/IEC60079-0;60079-15/61241-0;61241-1• Productstandards:EN/IEC60598-1;60598-2-22• EMCstandards:EN/IEC55015;61547• Otherstandards:EN/IEC60529(IP);62262(IK)

FNES LED

Zone 2 - 21 and 22 II 2 D and II 3 GD

ATEX / IECEx IP66/67 - IK10

Optimum operating temperature for battery is 23 °F/-5 °C to 86 °F/+30 °C.

Page 2: FNES LED Series Self-Contained Emergency Lighting with ...w3.cebeo.eu/pdf_nl/4573328.pdf · Lighting I S AFETY/ FL L KHEAD o ee a o ona a (800) 621-106 Deee 2011 262 FNES LED Series

LightingLighting: increased safety/fLameproof — BuLkhead

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © December 2011

261

Catalog Numbering Guide

FNES LED XX A A

Series:FNES

Zone2,21and22ATEX/IECCertified

LampType:LED

CableEntry:A-ArmoredM20U-UnarmoredM20N-Unarmored

SL-SpaceLightingE-EscapeRouteLighting

Options:A-AddressableW-WithSwitch(Automaticmainscut-off)

Unswitched Version – 1 hour duration - Non-maintained - Two M20 clearance entries

Type Power and Lamp Lumen Output Weight (kg) Volume (dm3) Pack Catalog Number

SpaceLightingLEDArray

540lm 7.2 32.3 1 FNESLEDSLU

EscapeRouteLighting 55lm 7.2 32.3 1 FNESLEDEU

Accessories

Description Catalog Number

Half Clamps Brackets - Set of Two

1-1/4"(dia.42mm)to1-1/2"(dia.49mm)

Zincplatedsteel FEHC49Z

316stainlesssteel FEHC49S

2"(dia.60mm)

Zincplatedsteel FEHC60Z

316stainlesssteel FEHC60S

M8 Ring Bolts - Set of Two

Zincplatedsteel FERBM8Z

Hinged Brackets - Set of two brackets for adjusting luminaire when wall-mounted

Aluminum(graypainted) FEHBA

316stainlesssteel FEHBS

Brackets for Surface Mounting - Set of two

Aluminum(graypainted) FESBA

316stainlesssteel FESBS

Fixing Brackets - Set of two brackets for ease of surface installation

Zincplatedsteel FEFBZ

316stainlesssteel FEFBS

FNES LED Series Self-Contained Emergency Lighting with Self-Test SystemZone 2 - 21 and 22

Zone 2 - 21 and 22 II 2 D and II 3 GD

ATEX / IECEx IP66/67 - IK10

CableEntry:A-ArmoredM20U-UnarmoredM20N-Unarmored

Series:FNES

Zone2,21and22ATEX/IECCertified

Page 3: FNES LED Series Self-Contained Emergency Lighting with ...w3.cebeo.eu/pdf_nl/4573328.pdf · Lighting I S AFETY/ FL L KHEAD o ee a o ona a (800) 621-106 Deee 2011 262 FNES LED Series

Ligh

ting

Light

ing:

incr

ease

d sa

fety

/fLa

mepr

oof

— Bu

Lkhe

ad

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © December 2011

262

FNES LED Series Self-Contained Emergency Lighting with Self-Test SystemZone 2 - 21 and 22

Zone 2 - 21 and 22 II 2 D and II 3 GD

ATEX / IECEx IP66/67 - IK10

Electrical Wiring Diagram

PE N L (B) (A)

Non-MaintainedEmergency

Lighting Unit

U

N

PE

-(B)

+(A)

Mains Remote (Optional)- +

LED Indicator

Battery not Connected or Faulty

Dimensions (in/mm)

15.8/400

31.0/785

2 x M8

8.54/217

5.71

/145

Page 4: FNES LED Series Self-Contained Emergency Lighting with ...w3.cebeo.eu/pdf_nl/4573328.pdf · Lighting I S AFETY/ FL L KHEAD o ee a o ona a (800) 621-106 Deee 2011 262 FNES LED Series

LightingLighting: increased safety/fLameproof — BuLkhead

Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © December 2011

263

LED Indicator

FNES LED Series Self-Contained Emergency Lighting with Self-Test SystemZone 2 - 21 and 22

Zone 2 - 21 and 22 II 2 D and II 3 GD

ATEX / IECEx IP66/67 - IK10


Top Related