Cooling Solutionsfor the IT environment
� For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-�89-6�68
Heat Density
(per rack)
Server Room / Wiring Closet
Solutions Product / Applications Data Center Solutions Product / Applications30 kW &
above
Rack Air ContainmentHigh Density RacksBest predictability
23 kW Hot Aisle Containment SystemHigh Density ZonesBest capacity sharingBest predictabilityBest floor space utilizationImproved redundancy and efficiency
10 kW
InRow™ RC & CDU, RPMedium to high densitymodular and scalable
7 kW
InRow SCIn-row air conditioning for server rooms and wiring closets
Air Removal UnitHot spot problem solver
4 kW
NetworkAIR PAPortable, self-contained air conditioning
NetworkAIR FMLow densityVery flexible
Wiring Closet Ventilation UnitRapidly deployable wall and ceiling mount heat removal
Air Distribution UnitRaised floor air distribution
Side Air Distribution UnitSide to side air distribution
System-level solutions for data centers on demand
InfraStruXure, APC’s innovative methodology for designing, deploy-
ing and optimizing data centers, fully integrates power, cooling,
security, and environmental management within a rack-optimized
design. Using an open, building-block approach, InfraStruXure
allows the selection of standardized components to create a solu-
tion through modular configurations. This standardization enables
an easily scalable architecture designed to meet changing needs
and future expansion. This award-winning, patent-pending approach
increases availability, improves adaptability, speeds deployment,
and lowers the total cost of ownership for IT environments—from
wiring closets to server rooms to data centers.
“ APC has the complete cooling solutions line for your data center
needs. We offer a range of products to meet all density levels for
wiring closets, small, medium, and large data centers. Our highly
efficient, scaleable solutions with active response controls offer pre-
dictable cooling for your needs today and in the future.”
Donna WilliamSDirector, Product Line Management, Cooling Solutions
moDular/HigH-DenSity air ConDitioning 4infraStruXure® inrow™ rC
infraStruXure® Cooling Distribution unit
infraStruXure® inrow™ rP
infraStruXure® inrow™ SC
Hot aisle Containment System
rack air Containment System
air DiStribution/FanS 9Wiring Closet Ventilation unit
rack air removal unit SX
rack air Distribution unit
rack Side air Distribution unit
room air ConDitioning 13networkair Fm
networkair Pa
Heat rejeCtion 15Chillers
The support structure of all highly available networks consists of power, cooling, racks and physical structure, security and fire protection, cabling, and the management and servicing of these elements.
For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-�89-6�68 3
Heat Density
(per rack)
Server Room / Wiring Closet
Solutions Product / Applications Data Center Solutions Product / Applications30 kW &
above
Rack Air ContainmentHigh Density RacksBest predictability
23 kW Hot Aisle Containment SystemHigh Density ZonesBest capacity sharingBest predictabilityBest floor space utilizationImproved redundancy and efficiency
10 kW
InRow™ RC & CDU, RPMedium to high densitymodular and scalable
7 kW
InRow SCIn-row air conditioning for server rooms and wiring closets
Air Removal UnitHot spot problem solver
4 kW
NetworkAIR PAPortable, self-contained air conditioning
NetworkAIR FMLow densityVery flexible
Wiring Closet Ventilation UnitRapidly deployable wall and ceiling mount heat removal
Air Distribution UnitRaised floor air distribution
Side Air Distribution UnitSide to side air distribution
3 kW
Ensuring the proper environment for IT systems is essen-
tial to maintaining high availability. Regardless of applica-
tion, IT equipment produces heat that can be damaging to
both uptime and the longevity of your investment.
Designed to provide cool air distribution and heat remov-
al in any IT environment at the rack, row, and room level,
APC cooling solutions give you the maximum amount
of cooling in the least amount of floor space. Scalable
solutions, including air distribution/fans, portables, and
precision cooling systems, are tailored to meet the unique
cooling demands of your environment, from wiring clos-
ets and computer rooms to data centers of all sizes.
4 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Modular/HIgH denSITy aIr CondITIonIng
InfraStruXure® Inrow™ rCIn-row air conditioning for medium to large data centers
including high density applications.
Data center heat densities continue to increase, making it more diffi-
cult to provide adequate cooling. To ensure proper airflow paths the
distance between the heat source and heat removal system must
decrease. The in-row concept closely couples cooling with heat load,
preventing exhaust air recirculation to sensitive IT equipment. The
InfraStruXure InRow RC is a computer room air conditioning system
designed for installation in the row to maximize sensible cooling
and increase efficiency. The unit captures heat directly from the hot
aisle and distributes cool air ensuring that equipment temperatures
are constantly held to setpoint conditions. The energy-efficient
design lowers total cost of ownership by monitoring IT equipment
inlet temperatures to modulate capacity based on the demand for
cooling. Fan speed is controlled based on the demand to reduce
energy consumption during off-peak cooling periods. Heat rejection
for the unit can be handled through an existing chilled water system
or an APC-supplied chiller. The modular, scalable solution improves
agility by enabling you to add cooling as demand increases, making
the InRow RC ideal for small to large datacenters.
Features and benefits
Availability • Active response controls Monitor and actively adjust cooling capacity
to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
• Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
• Dual A-B power inputs Draws power from the UPS for power protection with dual feeds for redundancy.
• Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Total Cost of Ownership • Variable speed fans Variable speed fans reduce energy consumption
during off-peak cooling periods.
• In-Row architecture In-row architecture enables pay-as-you-grow deployment of cooling.
Manageability • Microprocessor controller Utilizes intelligent, proactive control and
real-time capacity monitoring. The system is controlled by a master microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display.
• Building management system integration Sends alarms and data points allowing you to manage critical building infrastructure from a single system.
• Infrastruxure manager compatible Enables centralized management via the APC InfraStruXure® Manager.
ACRC100 ACRC103
Cooling Option Chilled Water
Capacity up to 30 kW
Airflow 2900 CFM
Nominal Input Voltage 100V,120V 200V
Input Power 1100 Watts 1380 Watts
Input Frequency 50/60 Hz
Rack Height 42U
Input Connections NEMA L5-20P IEC 309 16A 2P+E
Control panel Multi-function LCD status and control console
Maximum Height 78.39 in (1991.00 mm)
Maximum Width 11.81 in (300.00 mm)
Maximum depth 42.126 in (1070.00 mm)
Net Weight 358 lbs. (162.73 kg)
Color Black
Units per Pallet 1
Regulatory Approvals cUL Listed,FCC Part 15 Class A,ICES-003,Industry
Canada,MEA,UL Listed,VCCI
C-tick,CE,EN 55022 Class A,EN 55024,EN 60950,IEC 60950,IEC 61000-3-2,IEC
61000-3-3,MEA,VDE
Standard Warranty 1 year (parts only)
Agility • Modular design Provides scalable solutions to add cooling as demand
increases.
Serviceability • Hot swappable fans Allow system to remain operational if a fan
replacement is required.
5For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
InfraStruXure® Cooling distribution unitFlexible chilled water distribution system for the
InfraStruXure® Inrow™ rC.
The Cooling Distribution Unit provides centralized cooling, balanc-
ing and distribution through jointless and flexible chilled water
piping in the data center. The Cooling Distribution Unit and Chilled
Water Whip system allows for quick deployment and enables
customer infrastructure the flexibility to grow and change with
minimal labor and installation costs.
PEX-AL-PEX piping, used for chilled water piping between the
CDU and InRow RC, allows the chilled water to be routed without
the use of elbows or any intermediate joints from the CDU to each
InRow RC. This application greatly improves the reliability of the
system by dramatically reducing the chance of leakage.
PEX-AL-PEX is a multi-layered composite tubing consisting of
aluminum tubing sandwiched between inner and outer layers of
cross-linked polyethylene, providing flexibility of the piping to be
routed through the data center with the rigidity to stay in place.
With smooth interior walls and the chemical properties of the
material, PEX-AL-PEX is resistant to mineral buildup, corrosion,
and the risk of pinholes. The multi-press fittings provide a reliable
and leak resistant connection to both the CDU and InRow RC.
The individual chilled water lines to the RC are both flexible and
jointless, enabling customer infrastructure to be deployed quickly,
added for future expansion, or rerouted with minimal time as
demands change.
Features and benefits
Agility • Flexible piping Flexible piping allows for quick deployment and start up.
Availability • Jointless piping Jointless piping minimizes the risk of fluid leaks.
Serviceability • Coolant isolation Allows isolation of cooling circuits for servicing.
ACFD12-CXX-T ACFD12-CXX-B
Cooling Options Glycol, Chilled Water
Capacity up to 12 InRow RC units
Maximum Height 78.40 inches (1991 mm)
Maximum Width 42.13 inches (1070 mm)
Maximum depth 29.53 inches (750 mm)
Net Weight 500 lbs. (227.27 kg)
Color Black
Units per Pallet 1
Regulatory Approvals cUL Listed,MEA,UL Listed
Standard Warranty 1 year (parts only)
Modular/HIgH denSITy aIr CondITIonIng
6 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Modular/HIgH denSITy aIr CondITIonIng
InfraStruXure® Inrow™ rPIn-row precision air conditioning for medium to large data
centers including high density applications.
InfraStruXure InRow RP is a high capacity precision air condition-
ing unit designed to maximize sensible cooling for high efficiency
operation. The InRow RP product increases the capacity range
for chilled water applications and includes an air cooled solution.
Both the chilled water and air cooled products offer the ability to
control humidity with canister humidifiers and electric reheat,
enabling data center designs to leverage the InRow Architecture
for both sensible cooling of the IT load in the row, and humidity
control of the entire data center. The in-row concept closely cou-
ples cooling with the heat load, preventing exhaust air recircula-
tion to sensitive IT equipment. The energy-efficient design lowers
total cost of ownership by monitoring IT equipment inlet tem-
peratures to modulate capacity based on the demand for cooling.
Fan speed is controlled based on the demand to reduce energy
consumption during off-peak cooling periods. The modular, scal-
able solution improves agility by enabling you to add cooling as
demand increases, making the InRow RP ideal for small to large
data centers.
Features and benefits
Availability • Active response controls Monitor and actively adjust cooling capacity
to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
• Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
• Rack inlet control Guarantees inlet temperature to IT equipment.• Steam humidifier Humidity is managed through a self-contained steam
canister humidifier for maximum efficiency and ease of maintenance. The pure-steam canister maintains consistent capacity output, and requires very little scheduled maintenance.
• Real-Time capacity monitoring Real-time display of current and available cooling.• Electric reheat Prevents overcooling during dehumidification
Total Cost of Ownership • Variable speed fans Reduce energy consumption during off-peak cooling
periods.• In-Row architecture Enables pay-as-you-grow deployment of cooling.
Agility• Modular design Provides scalable solutions to add cooling as demand
increases.
Serviceability• Field replaceable components Fans and electronics module can be
readily replaced without uninstalling the unit.
Manageability• Microprocessor controller An 80-character LCD backlit alphanumeric
display provides communication and alarm indication.
ACRP100 ACRP101 ACRP102 ACRP500 ACRP501 ACRP502
Cooling Options R407C Chilled Water
Capacity 10–37 kW up to 70 kW
Airflow 4800 6950
Nominal Inout Voltage 200–240 3PH 460–480 3PH 380–415 3PH 200–240 3PH 460–480 3PH 380–415 3PH
Input Power 13737W 11212W 13056W 3204W 2054W 2818W
Input Frequency 50/60 60 50 50/60 60 50
Input Connections Hardwire 4-wire (3PH+G)
Warranty 1 year parts only
7For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
Modular/HIgH denSITy aIr CondITIonIng
InfraStruXure® Inrow™ SCrapidly deployable, in-row air conditioning for server rooms
and wiring closets.
New technologies are increasing heat loads in today’s server rooms
and wiring closets, which often lack adequate cooling. The APC
InfraStruXure InRow SC is a self-contained cooling solution that
maximizes availability within small IT rooms. This energy-efficient
unit lowers operating costs by using variable speed fans, capacity
modulation, and an in-row form factor. The InRow SC’s plug-and-
play design allows for rapid installation without the need for running
refrigerant lines or providing remote heat exchangers. The predictive
failure notification and high head pressure protection features, along
with hot-swappable fans, improve the availability of IT equipment.
Features and benefits
Agility • Easy to install Self-contained design allows for fast installation without
refrigerant lines or remote heat exchangers. Unit requires only power, condensate drain and an available return plenum to provide effective cooling.
• In-Row architecture Provides increased predictability of cooling performance.
• Modular design Provides scalable solutions to add cooling as demand increases.
Manageability • Real-Time capacity monitoring Displays current and available cooling.
• Microprocessor controller Displays an 80-character LCD backlit alphanumeric display that provides communication and alarm indication.
• Network manageable View the user interface with a browser. Gives quick access from anywhere on the network
• InfraStruXure Manager compatible Enables centralized management via the APC InfraStruXure Manager.
• Building management system integration Allows you to send alarms and data points to manage critical building infrastructure from a single system.
Availability • Ducted condenser air Uses unconditioned air from plenum space to reject
the heat rather than conditioned room air.
• Built-In condensate pump Factory installed pump collects and removes water from the air conditioner, ensuring continuous operation.
• High head pressure protection Ensures the InRow SC remains operational even when the condenser inlet air is restricted or very hot.
• Coil freeze protection Hot gas bypass prevents evaporator coil from freezing during light load conditions.
• Predictive failure notification Maximizes system availability by providing early warning of required fan or filter replacement.
• Automatic restart In the event of a power failure the InRow™ SC will resume operation.
Serviceability • Hot swappable fans Allow system to remain operational if a fan
replacement is required.
• Washable filters Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
Total Cost of Ownership • Rack inlet temperature control Reduces the risk of hot spots at the rack level.• Variable speed fans Reduce energy consumption during off-peak cooling
periods.• Green refrigerant Environmentally friendly refrigerant that can offer LEED points.
ACSC100 ACSC101Cooling Option R410A
Capacity up to 7 kW
Compressor Type Rotary
Air Discharge Patterns Horizontal
Intake Air Rear Return
Refrigerant R410A
Air Flow 1200 CFM
Nominal Input Voltage 200V, 208V, 230V
Input Power 2940 Watts 2530 Watts
Input Frequency 60 Hz +/- 3 Hz 50 Hz +/- 3 Hz
Input Connections NEMA L6–20P IEC 309 16A 2P+E
Control panel Multi-function LCD status and control console
Maximum Height 1991.00 mm
Maximum Width 300.00 mm
Maximum depth 1069.00 mm
Net Weight 165.91 kg
Color Black
Regulatory Approvals BSMI,EN 55022 Class A,FCC Part 15 Class A,ICES-003,UL
Listed,VCCI,VDE, CCC
BSMI, EN 55022 Class A, FCC Part 15 Class A,
ICES-003,UL Listed, VDE, VCCI C-tick, CE, CCC
Standard Warranty 1 year repair or replace
Modular/HIgH denSITy aIr CondITIonIng
8 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
Modular/HIgH denSITy aIr CondITIonIng
Hot aisle containment for high-density configurations.
Mixing of hot and cold air streams in the data center lowers avail-
ability of IT equipment. Returning the warmest possible air to the
computer room air conditioners increases the efficiency and capacity
of the system. The hot aisle containment system ensures proper air
distribution by completely separating supply and return air paths.
The hot aisle is sealed off using doors and transparent ceiling tiles
that extend the width of the hot aisle. Ceiling tiles are available for
both 19” and 23” racks. Two-rack kits complete with ceiling tile and
hardware are available for future expansion.
Features and benefits
Availability • Cable access brush strip Blocks air from escaping through holes
surrounding cabling.
Agility • Ceiling tiles Close off the top of the hot aisle to prevent warm air from
mixing with room air.
Hot aisle Containment
rack air Containment
Modular air containment system designed to maximize
cooling predictability, capacity, and efficiency.
Deployment of high density loads in IT environments can create areas
of unpredictable cooling performance. APC’s Rack Air Containment
is a modular system designed to work in conjunction with APC
NetShelter® SX enclosures and InRow™ cooling units to provide max-
imum cooling predictability, capacity, and efficiency. By attaching
to the rear of the NetShelter SX, air exhausted from IT equipment
is forced to pass through the cooling unit where it is conditioned.
This ensures that warm exhaust air does not find its way back to
the air inlets of installed servers. N+1 and 2N configurations allow
for maximum availability. Front containment can also be added to
provide additional isolation and noise dampening.
Features and benefits
Adaptability • Modular design Compatible with standard NetShelter SX racks, providing
maximum system flexibility and scalability.
• Front containment Ensures cold supply air is not captured by neighboring equipment.
• Rear containment Ensures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.
• One-way locking door Secures the hot aisle while allowing for quick exit in case of emergency.
• Scaleable densities Allow higher density cooling to be achieved by integrating the hot aisle containment system with in-row architecture.
• Modular design Modular design provides scalable solutions to add cooling as demand increases.
Total Cost of Ownership • Energy efficiency Increases cooling capacity of the associated air
conditioners without driving up power consumption.
Availability • Redundancy Systems can be configured to included an additional InRow
cooling unit to provide N+1 or 2N redundancy.
• Integrated pressure sensors Pressure sensors in the InRow cooling units provide fan speed control for optimum system efficiency.
Convenience • Noise dampening Containment of both front and rear provides reduction of
noise caused by installed equipment.
• Plexiglass door inserts Provides required air containment and a consistent look across the racks while allowing visibility to installed IT equipment.
• Easy to install Innovative design allows for fast, easy installation by almost anybody.
Modular/HIgH denSITy aIr CondITIonIng
9For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
Wiring Closet Ventilation unitrapidly deployable wall and ceiling mount heat removal for
wiring closets.
Wiring closet heat loads are rising due to deployment of tech-
nologies such as VoIP and Power over Ethernet. The Wiring Closet
Ventilation Unit is a rapidly deployable wall and ceiling mount heat
removal system designed specifically for the wiring closet environ-
ment. By exhausting hot air from the closet to an adjacent space
it allows conditioned air (entering through the Air Intake Grill) to
cool the load. Dual fans increase availability while LED status indi-
cators and dry contact outputs enhance the unit’s manageability.
Selectable fan speeds allow the user to choose between maximum
performance and quiet operation.
Features and benefits
Availability • Fault-tolerant fan system In event of a fan failure the remaining fan
automatically speeds up to compensate. Fans are N+1 redundant up to 300 CFM of airflow.
• Selectable speed fans Selectable fan speed (high/low) via toggle switch provides options for maximum performance or quiet operation.
Adaptability • Multiple mounting methods Flexible design allows for both drywall and
ceiling mount installations.
• Easy to install Innovative design allows for fast, easy installation by almost anybody.
• Hardwire capable For installations where hard wiring is required or prefered.
• Architecturally neutral Unobstrusive design and coloring blends in with the surroundings.
Manageability • Predictive failure notification Maximizes system availability by providing
early warning of required fan replacement.
• Dry contact output Provides remote notification of failures when used with APC environmental monitoring unit or system.
• LED status indicators Provide visual notification of fan failure.
ACF301
Cooling Capacity Options 3 kW of heat removal
Air Flow 475.00 CFM
Nominal Input Voltage 100–240V, 50/60 Hz
Input Power 85 Watts Input
Input Connections Hard Wire 3-wire, IEC-320 C14, NEMA 5-15P
Maximum Height 12.80 inches (325 mm)
Maximum Width 17.10 inches (434 mm)
Maximum depth 7.00 inches (178 mm)
Color White
Regulatory Approvals cUL Listed,CE,EN 55022 Class A,EN 55024, FCC Part 15 Class A,VCCI
Standard Warranty 2 years repair or replace
aIr dISTrIbuTIon/FanS
10 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
rack air removal unit SXPerformance heat removal for high-density equipment in
netShelter® SX and VX enclosures.
High-density equipment creates an environment where traditional
air distribution methods are often not effective. Densely packed
enclosures can cause IT equipment to overheat, resulting in down-
time. The Rack Air Removal Unit SX captures exhaust heat, duct-
ing it to the return air plenum and eliminating hot spots. Through
automatic fan speed adjustment based on temperature or power
consumption, the fans will self-adjust for optimal performance.
With a unit-mounted LCD display users can view temperatures at
the rack, monitor alarm conditions and adjust unit set points. The
integrated network management card allows for remote monitor-
ing and control of the Rack Air Removal Unit SX. This space-sav-
ing product mounts to the back of either the NetShelter SX or VX
enclosure – requiring zero U space.
Features and benefits
Manageability • Network manageable View the user interface with a browser. Gives quick
access from anywhere on the network
• InfraStruXure® Manager compatible Enables centralized management via the APC InfraStruXure Manager.
• Temperature monitoring Allows up to 3 remote sensors to monitor rack inlet temperature.
• LCD display Accessible without opening the door for easy operation. Allows user to locally monitor and control the unit.
Availability • Fault-tolerant fan system In event of a fan failure the remaining fans will
speed up to compensate. Fans are N+1 redundant up to 1500 CFM of airflow.
• Dual A-B power inputs Draw power from the UPS for power protection with dual feeds for redundancy.
• Ducted Exhaust System Removes hot air from the data center to prevent recirculation and eliminate air mixing.
• Field replaceable components Fans and electronics module can be readily replaced without uninstalling the unit.
Adaptability • Adjustable mounting frame The frame can mount on Netshelter SX or VX
enclosures and extends to accommodate 42U, 47U or 48U rack heights.
• Zero “U” Solution Mounts to the rear of the rack, leaving valuable rack space for other equipment.
Total Cost of Ownership • Easy to install Innovative design allows for fast, easy installation by almost
anybody.
• Variable speed fans Reduce energy consumption during off-peak cooling periods.
• Increased capacity Higher rate of heat removal allows more equipment to be installed in each rack.
ACF400 ACF402
Cooling Capacity Options 23 kW
Air Discharge Patterns Upflow,Ducted Upflow,Ducted
Air Flow 2000 CFM
Nominal Input Voltage 100V,120V,200V,208V,230V
Input Power 1200 Watts
Input Frequency 50/60 Hz
Input Connections IEC-320 C14, NEMA 5–15P
Control panel Multi-function LCD status and control console
Maximum Height 1918.00 mm
Maximum Width 597.00 mm 737.00 mm
Maximum depth 254 mm
Net Weight 67.27 KG 77.27 KG
Color Black
Regulatory Approvals cUL Listed,CE,EN 55022 Class A,EN 55024,FCC Part 15 Class A,ICES-003,IEC 61000-3-2,IEC 61000-3-3,UL Listed,VDE,VCCI
Standard Warranty 2 years repair or replace
aIr dISTrIbuTIon/FanS
11For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
rack air distribution unitair distribution for power dense enclosures and low
pressure areas
The Rack Air Distribution Unit is a 2U fan unit that works with an
existing precision air conditioning system to deliver cool air to the
equipment contained in a rack enclosure. The Rack Air Distribution
Unit connects into the raised floor and pulls supply air directly into
the enclosure. This prevents the conditioned air from mixing with
warmer room air before reaching the equipment.
The Rack Air Distribution Unit minimizes temperature differences
between the top and bottom of the enclosure. It also prevents hot
exhaust air from recirculating to the inlet of the enclosure.
The product is recommended for rack enclosures with loads
greater than 1.5kW and can provide airflow for loads up to 3.5kW.
It is also ideal for enclosures in raised floor environments where
underfloor air distribution is inadequate.
Features and benefits:
Availability• Dual fans Deliver air to equipment in the rack where floor tile velocity is
inadequate for proper cooling.
• Raised floor duct Delivers cool, conditioned air directly from the raised floor to the inlet of the IT equipment.
Agility• Air filtration Removes dirt and other particulates from the intake air for
cleaner supply air.
• Fan control switches Users can turn one or both fans on and off depending on the heat load.
• Mounting rails Adjustable depth allows the unit to fit APC's NetShelter® enclosure or other 19" EIA-310-D enclosure.
• Fan guards A safety measure that provides protection from the fan opening by covering the inlet.
Total Cost of Ownership• Dual A-B power inputs Draw power from the UPS for power protection
with dual feeds for redundancy.
ACF001 ACF002 ACF003
Air Flow 503 CFM 420 CFM 503 CFM
Amp Draw Nominal 2A 1A 2A
Nominal Input Voltage 120V 208V, 230V 100V
Input Power 240 Watts 230 Watts 200 Watts
Input Frequency 60 Hz +/- 1Hz 50/60 Hz 50/60 Hz
Rack Height 2U
Input Connections C-13 NEMA 5–15P
C-13 IEC-320 C14
C-13 NEMA 5–15P
Maximum Height 89.00 mm
Maximum Width 422.00 mm 421.00 mm
Maximum depth 737 mm
Net Weight 18.64 KG
Color Black
Regulatory Approvals UL Recognized CE, UL Recognized
METI Denan, UL Recognized
Standard Warranty 2 years repair or replace
aIr dISTrIbuTIon/FanS
12 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
ACF201BLK ACF202BLK
Nominal Input Voltage 120V 208V, 230V
Input Power 150 Watts
Input Frequency 60Hz 50/60Hz
Air Flow 260 CFM
Amp Draw Nominal 2 A 1 A
Net Weight 32 lbs (15kg)
Max. Height 3.44 inches (87.4 mm)
Max. Width 16.98 inches (431 mm)
Max. Depth 26.34 inches (669 mm)
Color Black
Approvals UL Recognized CE
Standard warranty 2 years repair or replace
air distribution for networking equipment with side to
side airflow
Housing equipment with side to side airflow creates many chal-
lenges for IT and facility managers, particularly in regards to cool-
ing. Because most enclosures are designed for a front to back air-
flow pattern, it is difficult to maintain ideal operating temperatures
on side to side airflow equipment. The Rack Side Air Distribution
Unit allows for greater security and organization by allowing racks
to be placed adjacent to one another without impeding airflow.
The Rack Side Air Distribution Unit is a 2U rack mountable air
distribution product for networking equipment or servers with
side to side airflow. It pulls in conditioned air from the front of
the rack and distributes it to the side air intake of the networking
equipment. This extends equipment life by providing proper inlet
temperatures.
This product is recommended for one or more networking products
that are stacked consecutively in a rack. Rack Side Air Distribution
Units may be placed above and/or below the networking equip-
ment. Airflow pattern is user configurable via an interchangeable
air turning vane.
Features and benefits:
Availability• Dual fans Deliver air to equipment in the rack where floor tile velocity is
inadequate for proper cooling.
• Fan control switches Users can turn one or both fans on and off depending on the heat load.
Agility• Mounting rails Adjustable depth allows the unit to fit APC's NetShelter®
enclosure or other 19" EIA-310-D enclosure.
• Fan guard A safety measure that provides protection from the fan opening by covering the inlet.
Total Cost of Ownership• Dual A-B power inputs Draw power from the UPS for power protection
with dual feeds for redundancy.
• Air turning vane Directs air up or down the side of the rack, supplying cool air to the inlet of side to side airflow equipment.
Manageability• LED status indicators Indicate the operating condition of the unit including
power-on and alarm state.
rack Side air distribution unit
aIr dISTrIbuTIon/FanS
13For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
Economy• Dedicated dehumidification Boosts system efficiency by adding latent
capacity without overcooling or increasing the requirement for reheat, resulting in up to 15% lower energy consumption (N/A chilled water systems).
• SCR electric reheat Modulates capacity to save energy. Exacting amounts of reheat loaded equally on all three phases.
Manageability• Programmable input/output contacts Allows device contacts to be
connected to the air conditioner and mapped to customer outputs or system alarms.
• Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character alphanumeric display.
• Network interface Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
• Redundant group control Allows up to 4 groups of precision air conditioners to communicate with each other for redundancy, demand fighting prevention, mode assist, and global sharing of certain settings.
networkaIr® FMModular floor mount precision air conditioning for
environmentally sensitive equipment areas
The NetworkAIR FM utilizes leading edge precision air technolo-
gies. Modular construction, variable frequency drives, dedicated
dehumidification, tandem scroll compressors, and front service
access are all integrated into one high efficiency system. A scal-
able design enables customers to meet the changing needs of their
environments.
Features and benefits
Availability• Tandem scroll compressors Quiet and efficient operation of scroll
compressors, connected on a common circuit for staged capacity control (N/A chilled water systems).
• Direct drive motors Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced which lowers vibration and expedites startup. Eliminates the need for unreliable belts, pulleys and special bearings.
• Variable frequency drives Enable the fans to be soft started, saving energy during power up. Controlling the motor speed simplifies the adjustment for static pressure and gives the option of back-draft prevention.
• Steam humidifier Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure-steam canister maintains consistent capacity output, and requires very little scheduled maintenance.
Serviceability• Front service access The system has full service, front access for routine
servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
Protection• Double-walled panels Separates insulation from the air stream, which
prevents periodic maintenance of the insulation and reduces noise levels. Small particles of insulation can be picked up by the air stream if not isolated.
FM-DX 60Hz FM-CW 60Hz FM40H-AGB-ESD FM40B-CFB-ESD
Cooling Options Air, Water, Glycol, Economizer, Multicool Chilled Water Air Chilled Water
Humidification Capacity 10 lbs/hr 10 lbs/hr
Compressor Type / Refrigerant Tandem Scroll / R22 N/A Tandem Scroll / R407C N/A
Input Frequency 60 Hz 50 Hz
Nominal Input Voltage 208V 3PH, 480V 3PH, 600V 3PH 400V 3PH
Air Discharge Patterns Downflow, Upflow Front Return, Upflow Rear Return Downflow
Control Panel Microprocessor Controller
Net Weight 2,360 lbs (1072.73 kg) 1,180 lbs (536 kg) 2,360 lbs (1072.73 kg) 1,180 lbs (536 kg)
Max. Height 76.89 inches(1953.01 mm)
Max. Width 70.87 inches (1800.1 mm)
Max. Depth 35.00 inches (889.00 mm)
Approvals CSA, MEA, UL Listed CE, Eurovent
Standard Warranty 1 year (parts only) optional extended warranties available.
rooM aIr CondITIonIng
14 For more information about APC’s Cooling Solutions, visit www.apc.com or call 1-888-289-6268
ACPA4000 AP7003
Cooling Capacity 3.9kW 1.6kW
Cooling Options Air
Compressor Type Rotary
Nominal Input Voltage 120V
Input Power 1,610 Watts 692 Watts
Input Frequency 60Hz
Coolant R22
Air Flow 600 CFM 170 CFM
Condensate Tank N/A 3.5 qt
Condensate Pump 1.6 gal/hr N/A
Approvals UL Listed
Standard Warranty 1 year repair or replace
networkaIr® Pa*
Portable, self-contained air conditioning solutions for small
rooms and data closets
Inconsistent and high temperatures can lower the expected life of,
and permanently damage your electronic equipment. IT refreshes
and equipment relocation result in unpredictable and ever-chang-
ing environments. The NetworkAIR PA provides portable cooling
for your sensitive electronic equipment to meet the environmental
demands of small rooms and data closets.
This self-contained solution does not require an external con-
denser, refrigerant piping, or building water source for operation.
Heat is rejected to a drop ceiling or adjacent area via a flexible duct
kit. The NetworkAIR PA can be installed quickly and inexpensively,
without the need for building modifications.
Features and benefits:
Availability • Automatic restart Returns the unit to its last operating status in the event
of a power failure, in order to protect the compressor and the environment. (Not available on the AP7003 unit).
• Ducting kit Allows hot air to be removed and distributed to a drop ceiling or hard-ducted return. This increases the efficiency of the computer room air conditioning system in both capacity and dehumidification.
• High head pressure protection Prevents compressor damage (not available on AP7003 unit).
Agility • Easy to install Self-contained, air cooled design allows for fast, easy
installation.
• Replacement ceiling tile Fits into a standard drop ceiling to provide a connection point for the ducting kit. (Not available on the AP7003 unit).
• Casters Provide flexibility to move the unit to wherever cooling is required.
Manageability • Network manageable Remotely monitor and control NetworkAIR PA4000
environmental information from anywhere on the network via a Web browser (not available on the AP7003 unit).
• LED status indicators Four (4) external status indicator LEDs represent: major alarm; minor alarm; check log (new alarm/warning has occurred); system on (evaporator blower is running). Not available on the AP7003 unit.
• On/off scheduling Allows the user to determine when the unit operates, saving energy costs. (Not available on the AP7003 unit).
*available in North America only
rooM aIr CondITIonIng
15For more information about APC’s Availability Cooling, visit www.apc.com or call 1-888-289-6268
air Cooled Modular Chillers*
air Cooled Chillers for air conditioning equipment in data
centers, server rooms and wiring closets.
APC air cooled chillers for air conditioning equipment in data
centers are a new generation of leading-edge technology. These
all-in-one integrated packages reduce time and cost of installation.
Features and benefits:
Manageability • Microprocessor controller Provides proactive control and real-time
monitoring via a four line, eighty character, alphanumeric display.
• ModBus translator Optional feature allows integration with Building Management System.
Total Cost of Ownership • Variable speed fans Reduce energy consumption during off-peak cooling
periods.
• Integrated hydronics package Includes all the necessary components to make one connection to the chilller without the need of external connections to auxiliary equipment such as pumps, increasing the speed of deployment.
Availability • Scroll compressors Utilize few moving parts for increased reliability and
life expectancy.
• Independent power feed Optional feed to the pumps allows for wiring to the UPS, thus ensuring chilled water availability during generator start-up when used with a storage tank.
• Dual redundant pumps Provide reliable chilled water flow sized for full capacity.
• Low ambient controls Enable chiller operation in temperatures down to -20°F.
Convenience• Optional storage tank Fits under chiller without increasing footprint.
SKU Series ACCH050 ACCH084 ACCH120 ACCH167 ACCH200 ACCH220
Capacity 50kW 84KW 120KW 167KW 200KW 220KW
UPSable pump (optional) Yes Yes Yes Yes N/A N/A
Storage tank option ACTA1100 ACTA1101 ACTA1102 ACTA1102 N/A N/A
Windbaffle option ACAC30001 ACAC30002 ACAC30003 ACAC30004 ACAC30005 ACAC30005
Voltages 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH 208/3PH, 480/3PH
Height in inches* 52 52 52 52 90 90
Width in inches* 82 108 108 108 95 95
Depth in inches* 43 43 90 90 89 89
Weight in lbs* 1298 1819 3134 3603 4705 4911
Standard Warranty 1 year (parts only), optional extended warranties available
* Weights and dimensions do not include storage tank or windbaffles
*available in North America only
HeaT rejeCTIon
For more information call:Tel: 800 800 4APC - US & CanadaTel: 401 789 0204 - World wide
APC CorporateAPC North America132 Fairgrounds RoadWest Kingston, RI 02892 USACall: 800 800 4APCFax: 401 789 3710
APC Latin America5301 Blue Lagoon Drive Suite #610Miami, FL 33126 USACall: 305 266 5005Fax: 305 266 9695
APC EuropeAPC IrelandBallybrit Business ParkGalway, IrelandCall: +353 91 702000Fax: +353 91 756909
APC Asia PacificAPC AustraliaLevel 13 The Denison65 Berry StreetNorth Sydney, NSW 2060Call: +61 2 9955 9366Fax: +61 2 9955 2844
Visit: www.apc.come-mail: [email protected] Support: : support. apc.com
©2007. All rights reserved. All APC trademarks are property of American Power Conversion. Other trademarks are property of their respective owners. Specifications are subject to change without notice. PART# 996-2854B
APC’s quality system is certified by ISO 9002 standards
Since 1981, APC has been a global leader in power availability solutions, setting the
industry standard for quality, innovation, and support. From its corporate head-
quarters in West Kingston, Rhode Island, APC operates sales offices throughout
the world and manufacturing facilities on four continents and distribution facilities on
five continents. APC ships products to over 150 countries.
Over 30 million satisfied customers worldwide depend on APC’s Legendary Reliability®.
Propelled by real-world experience and a drive towards technological innovation, APC
has the experience, scale, global presence, and stability to respond to emerging IT
availability needs.
Choose the optimal service solution to increase your system availability.
Receive your FREE APC white paper “Cooling Strategies for Ultra-High
Density Racks and Blade Servers”. Visit us online at http://promo.apc.com
and enter key code s369y.
As the recipient of hundreds of awards worldwide, APC is recognized for excellence in both its business and product performance. Every year since 1999, APC has been named to the Forbes Platinum 400 list of the Best Big Companies in America. For 11 years in a row, APC has received the Channel Champion award in the UPS category.
Cooling Strategies
for Ultra-high
density racks and
blade servers