GENERAL NOTES 1.0 CONSTRUCTION
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepancies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
Flush RevealsFinish glazing and door opening reveals with minimum 18mm thick customwood securedto studs & plates, completed with chamfered edges for taping and flushing smooth withplasterboard. Ensure fixing points are positioned behind proposed extrusion points whereapplicable.
Plasterboard TrimFinish external edges & internal corners with purpose made corner beads & stop beadsflushed smooth with plasterboard. Use continuous lengths to avoid joins
1.3 DEMOLITION
The demolition of all parts nominated is to be done within a pre-arranged program withthe Project Manager. It shall take place to cause least inconvenience to the Owner.Contractor to arrange for the tenancy to remain secure as demolition occurs. TheContractor shall allow for any temporary propping as a result of any items to bedemolished and to minimise interference to internal occupation.Apart from material nominated for re-use within this specification and contract drawings alldemolished materials become the property of the Contractor and shall be removed fromsite at the Contractors expense.
1.4 WALL PANELLING
Supply and install wall panelling where indicated on Smith Madden Group DWG.
1.5 OPERABLE WALLS
Install operable wall to area indicated on Smith Madden Group DWG.
Refer to Finishes Schedule for specification
Operable wall shall consist of top supported, manually operated panels that can be linkedtogether to form a sound retardant closure. Panels shall be constructed of a sandwich ofboard and/or steel separated by acoustics insulation to achieve the specified.
1.6 FIRE RATED PARTITIONS
Generally construct 2-hour fire rated partitions. Refer to Smith Madden Group DWG
Construct partitioning using 92mm steel studs removing ceiling tiles & tee bars asnecessary & restoring as modified. Clad both sides of partitions with two layers of 16mmthick plasterboard staggering joints.
1.7 TRIMS
Generally supply accessories and trim necessary to complete the installation.
1.7.1 Aluminium Glazing FramesInstall glazing frames where nominated on the drawings using extruded aluminiumsections unless otherwise noted in single lengths where possible and mitre corners.Aluminium frames to comply with A.S. 2047 & 2048.
Finish & Framing System: See Finishes Schedule.
1.7.2 Timber Glazing Frames
As per Smith Madden Group DWGS and Schedules.
1.7.3 Aluminium Door Frames
Install full height door frames to doors where nominated on the drawings using extrudedaluminium sections in single lengths and mitre corners. Install rubber covering strips tofixing channels and door seals.
1.7.4 Timber Door Frames
Finish & Framing System: See Door Schedule.
1.7.5 Timber Skirtings
Install full height polished door frames to doors as detailed - refer to door schedule.
As per Finishes Schedule.
1.7.6 Aluminium Skirting
Install 100mm high aluminium skirting to all internal partitioning unless otherwise noted.Use continuous lengths where possible to avoid joins and mitre at corners. Finish : SeeFinishes Schedule.
1.8 DOORS & HATCHES
Definition:
Doorset: An assembly comprising a door or doors and supporting frame, guides and tracksincluding the hardware and accessories necessary for satisfactory operation. Door types:To AS 2688. Installation: To AS 1909· Aluminium Door Sets Material and Performance: AS 2047.1· Construction and Installation: AS 2047.2
Refer to Door Schedule for details.
1.9 HARDWARE (DOOR & WINDOW)
Locks & Latches
Mechanical locksetsStandard: To AS 4145.2
Generally supply & install new hardware to all doors as specified on the door schedule.
DRAWING INDEX
ALL WORKS TO BE UNDERTAKEN IN COMPLIANCE WITH THE CURRENTAUSTRALIAN STANDARDS AND BCA.
This document is a generic scope of works and is intended to provide information for aminimum standard of installation for the works.
The Quotation to be based on but not limited to the following scope of works as per thedrawings and schedules provided by Smith Madden Group. Engineering drawings/scopeof works will be provided when required.
Please make provisions for any items not specified which may be necessary to make thework complete and perfect in all respects and ready for operation. Any additional itemsto be nominated as itemised costs.
The works to be carried out for this project shall be performed in accordance with thegeneral conditions & technical requirements equivalent to that existing on site.
The works shall comply with:o Building Control Acto Relevant Actso Industrial Codeso Current Issue of Relevant Australian Standardso Requirements of Relevant Statutory Authoritieso Occupational Health & Safety Requirementso Tenancy Guidelines for the Buildingo Other Local Regulations Relevant to such Installations
Australian Standards and codes & companion standards & codes current at the tenderdates shall apply to the contract works.
The contractor shall obtain necessary forms and give notice, in the format withsupporting information required to authorities having jurisdiction, obtain requiredapprovals & permits and pay associated fees including all council permit applicationsrelating to hoardings, footpaths, street closure etc.
New materials, equipment and components of first quality & current approvedmanufacturers of the various fittings, equipment and components shall be maintained.
The contractor shall:o Check all dimensions on architectural drawings and on site before construction.o Provide defect and warranty in accordance with the main contract.o Inspect the site and allow for all work necessary to complete the installation.
SHOP DRAWINGS:
Where Engineers drawings are not included PRINCIPAL CONTRACTOR to provideshop DWGS for Hydraulic, Mechanical, Electrical, Comms and Fire Protection Services,SMG and engineer approval for submission of a staged building permit.
TESTING/AS BUILTS CERTIFICATION:
Contractor for each service shall provide 3 hard copies and 1 soft copy (CD) of As BuiltDrawings and certification, inclusive of Certificate of Compliance on completion of Works.The drawings are to be completed using the contractor’s company title block on thedrawing.
Maximum 3 weeks after practical completion.
1.0 CONSTRUCTION
1.1 PRELIMINARIES
All contractors to refer to all of the relevant drawings as noted.
All drawings available upon request from Smith Madden Group. Refer to appropriateschedule for all finish, door, chair, joinery and appliances.
DRAWINGS/SCHEDULESRefer to Drawing Transmittal sheet for full list of project documentation
LOADING & OFF LOADING:Contractor will contact the Smith Madden Group Project Manager regarding the bookingof the goods lift, working hours & general regulations relevant to construction on site.
PARKING:There is no provision for private vehicle parking for trades personnel. Use public parking.
INSPECTION:Contractors will be required inspect the site at the mandatory briefing prior to submittingtenders.
PLASTIC SHEETING:Cover areas effected by partitioning and services alterations with plastic, overlapping andtaping joins in continuous lengths. Covered areas should extend a minimum of threemetres past the effected areas & include traffic points from & to lift cars and stairwells.Ensure all rips & tears in the plastic incurred during construction are repaired immediately.Adequately clean plasterboard dust and building debris from the plastic protection forcleaning of workboots prior to entering lifts or leaving the site.
WORKING HOURS:Normal working hours shall be worked, but some activities may need to be undertakenat times to minimise the disruption to the owner. Such work must agree with the ownerand sufficient notice of intent to perform such work must be given to the owner.
Head Contractor to allow for all slab penetrations, scabbing and chasing to be doneoutside office hours
DUST CONTROL:The Contractor shall allow for providing polyethylene sheet dust proofing between areasof work and areas of occupation.
TEMPORARY SERVICES:The Contractor shall provide sufficient notice of intents. The Project Manager must beprovided with seventy two (72) hours prior to work where services will be interrupted.
SET OUT:Every effort is made to provide sufficient dimensioning for setout. The Contractor shallnotify the Smith Madden Group Project Manager of discrepancies.
CLEANING:On completion thoroughly clean the structure and surroundings.
1.2 PARTITIONING
BCA COMPLIANCE:
General: The work under the Subcontract shall comply with the Building Code of Australia,including but not limited to requirement properties for acoustic attenuation and fireresistance.
Test certificates: Obtain from an Independent Testing Authority approved by theSuperintendent, test certificates which evidence compliance of the respective material,components and assemblies.
Fire Hazard: Comply with BCA requirements. Do not use materials which, when subjectto fire conditions, will emit excessive smoke or dangerous fumes.
CONSTRUCTION GENERALLY:
Refer to drawings for partition type. All partition walls to be type P1 unless otherwiseindicated on the drawings.
Construct partitions generally to manufacturer’s specification, Install studs with compatiblesteel top and base plates secured direct to substrate or suspended ceiling tee bars. Installadditional studs where overhead cabinetwork and fixtures are nominated for securefixings.
InsulationInstall insulation as per Smith Madden Group DWGS to all partitions packing tightlybetween studs & around conduits & the like for maximum sound attenuation unlessotherwise specified or shown on the drawings.
Acoustic Plaster BafflesExtend partitions full height above ceiling to U/S of slab where indicated on drawing.Allow for deflection head to U/S of slab. All holes in plaster due to services penetrations tohave caulking applied.
Acoustic Insulation above Ceiling TilesInsulation to ceiling board above ceiling. Install insulation above ceiling tiles as indicatedon drawings. Type Autex sound blanket ASB4 70mm.
Acoustic SealsEnsure Uniseal foam strips in continuous lengths are installed between top plates & ceilingsurfaces & between partition ends & masonry walls & columns for maximum soundattenuation.
PlasterboardStandard: To AS 2588 generally. To ASTM C630 for water-resistant plasterboard.
Grades:General areas: Standard grade.Moisture prone areas: Water-resistant grade.Fire rated installations: Formulated for additional resistance to fire exposure.Thickness (mm): Unless otherwise specified or shown on the Drawings,13 mm, generally.16 mm, for fire rated elements.Edge finish: Recessed for flush-set plaster joints.Fibre cementStandard: To AS 2908.2Type: Type B category 2.Type: Recessed edge for flush-set plaster joints.Thickness (mm): 6.FastenersSteel nails: Hot dip galvanizedAdhesivesContact adhesives: to AS2131.For plasterboard: To AS 2753.For wallboards: Mastic adhesive.
LiningAcoustic Performance CriteriaFor acoustic performance requirements, including but not limited to: linings, fixingmethods, acoustic isolation, etc.Acoustic PartitionsSTC 35: One layer of 13mm Gyprock either side of 64mm steel stud - no insulation.STC 40: One layer of 13mm Gyprock either side of 64mm steel stud with S3 insulation.STC 46: 2 layers of 13mm Gyprock one side and 1 layer of 13mm Gyprock other side of64mm steel stud with S4 insulation.STC 55: 2 layers of 13mm Fyrchek either side of 84mm staggered steel studs in 92mmsteel top and bottom tracks with S4 insulation.STC 62: 2 layers of 16mm Fyrchek either side of 92mm separated steel studs with S4insulation.Generally:· Clad both sides of studwork with 13mm recessed edged plasterboard, taping &sanding smooth sheet joins & fixing penetrations unless noted otherwise.· All partitioning is to be full height unless otherwise specified.· The existing ceiling height is to be confirmed on site as required. Check at variouslocations to gauge consistency of height.· Where indicated on the drawings half height partitions construct solid partitions toa height as indicated in Smith Madden Group DWG with glass above to full height.· Where partitions abut window mullions, paint reveal ‘black’ & install foam sealingstrip between mullion & partition reveal. Do not screw into window mullions. Wherepartitions do not abut window mullions, glazed fins to be installed and secured by siliconfixing.Cut around sills & ducted skirting as necessary in order to ensure flush joins betweenpartitions & substrate.
1.0 CONSTRUCTION
1.10 GLAZED PARTITION
DesignCertification: Submit certification from a Chartered Professional Engineer confirmingcompliance with AS 1288.Glass toleranceSize, squareness and flatness: To AS 2208.Plate and sheet (i.e. not patterned):
Overall bow and warpage: To AS 2208.Roller wave: Maximum 0.15mm
Float glass qualityGlazing Select Quality q3 to ASTM C 1026.Safety glassesStandard: To AS 2208.
Install clear nominal 10.38mm and/or 12.38mm glazing as required by appropriatebuilding codes and Australian Standards to frames specified to receive glass as shownon drawings.
Where glass panes join leave 10mm gap between panes and fill with clear siliconesealer, cutting smooth with the edges of the glass. All surplus silicone to be cut awayfrom joining.
1.11 PAINTING
GeneralPainting: Comply with the recommendations of those parts of AS 2311 and AS/NZS 2312
Paint the following surfaces in their respective finishes. Refer to SMITH MADDEN GROUPDWG & Schedules for exact locations of paint finishes.
Ceilings & Walls -Plasterboard· Ensure plasterboard is flat and smooth. Nominated areas shall be cleaned of allsurface pollutants to provide a sound surface for repainting. Remaining loose, flaking orblistered paintwork shall be removed by scraping and sanding to a firmly adhered edge.All edges shall then be feathered off using hand sanding prior to bare areas being spotprimed with a suitable primer for the surfaces concerned. Fill cracks and surfaceimperfections and patching plaster. Any gaps from structural movement should be filledwith a paintable flexible gap sealant. Sand smooth and dust off thoroughly
CEILINGS:· First Coat - Acrylic Sealer Undercoat· Second Coat - Wash and Wear Flat Acrylic· Third Coat - Wash and Wear Flat Acrylic
WALLS:
· First Coat - Acrylic Sealer Undercoat· Second Coat - Wash and Wear Low Sheen Acrylic· Third Coat - Wash and Wear Low Sheen Acrylic
Interior Timber - Timber including core doors. Ensure the timber is thoroughly drybefore commencing. Fix any defects such as splits, dents etc with acrylic wood filler andsmooth off. Remaining loose, flaking or blistered paintwork shall be removed by scrapingand sanding to a firmly adhered edge. All edges shall then be feathered off using handsanding prior to bare areas being spot primed with suitable primer for the surfacesconcerned. Make sure area is clean sound and dry.First Coat - PrimerSecond Coat -Semi Gloss EnamelThird Coat -Semi Gloss Enamel2 Pack Paint Finish to MDF - High GlossPrepare imperfections and fill nail holes. Sand smooth cut edges and dust down. Applyprimer and if necessary resand cut edges to smooth down raised fibres.First Coat - Luxepoxy 4 White PrimerSecond Coat - Acrathane IFThird Coat - Acrathane IF
Metal/Steel - Nominated areas shall be cleaned of all surface pollutants to provide asound surface for repainting. Remaining loose, flaking or blistered paintwork shall beremoved by scraping and sanding to a firmly adhered edge. All edges shall then befeathered off using hand sanding prior to bare areas being spot primed with a suitableprimer for the surfaces concerned.
First Coat - PrimerSecond Coat - High Gloss EnamelThird Coat - High Gloss Enamel
The substrates shall receive the following specified coating systems:Existing walls: touch up, one coat systemNew Walls: three coat systemExisting doors and frames: touch up onlyNew doors and frames: three coat systemExisting Stair steelwork touch up, one coat system
1.12 WHITEBOARDS & PINBOARD
Supplied & Installed by Head Contractor. See Loose Furniture Schedule for details.
1.13 CEILING (SUSPENDED)
GeneralSuspended ceilings: To AS 2785Luminaire & Diffuser interfaces; To AS 2946
1.13.1 Ceiling Grid & System Tile (New)
Head contracter to supply & Install new base building ceiling works including grid andtiles unless otherwise indicated.
The contractor is to furnish all materials, labour and equipment for the erection of theRondo Aluminium Ceiling System as indicated on the Smith Madden Group DWG.Rondo Aluminium Ceiling System shall be installed as recommended by manufacturer.
1.0 CONSTRUCTION
1.13.1 Ceiling Grid & System Tile (New) Cont...
Cross Runners shall intersect Main Runners and be positively locked together.Wall angle shall be securely fastened to the wall @ 600mm centres.Ceiling grid to have maximum deflect 1/360o. Extra hangers are to be provided forlight fittings, air conditioning units etc. that are supported by the grid system.
Ceiling Tile : refer to Finishes Schedule.
1.13.2 Ceiling Grid & System Tile (Existing)
The Head Contractor will be responsible for removing existing ceiling tiles for ease ofaccess to ceiling cavity. Store removed ceiling tiles on site and in area nominated bythe Building Supervisor. On completion of trade works, replace stored tiles toprevious positions.Head Contractor will be responsible for replacing any damaged ceiling tiles and teesuspension bars as necessary or as directed by the Project Manager.Partitioner shall allow to supply and install ceiling tiles where all redundant servicessuch as sprinkler heads, mechanical register, light fittings have been removed orrelocated.Partitioner to allow for minimum 10% replacement ceiling tiles as part of tender.
1.13.3 New Flush Plasterboard
Supply and install flush plasterboard suspended ceiling system.Supply and install flush plasterboard ceiling as recommended by manufacturer.The Primary Rail shall be hung on 5mm adjustable suspension rod accurately leveled.Suspension clips shall be at 1200mm centres along primary rail. Primary rails spacedout at 1200mm centers. Furring channels shall run at right angles to the primaryrails and be positively lock at maximum 600mm centers.Screw fixed 13mm plasterboard to furring channels at maximum 200mm center.Tape and set plasterboard joints suitable for painting.Supply and install control joints at 12m maximum centers in both directions.Provide additional hangers to support lights, air-conditioning etc. as required.Refer to Smith Madden Group DWG.
1.13.4 Flush Plasterboard Bulkhead
Contractor to supply and install flush plasterboard bulkheads including recessed lightcoffer as indicated on ceiling drawing and details.Refer to Smith Madden Group DWG
1.13.5 2-Hr Fire Rated Flush
Contractor to install 2-hour fire rated ceiling according to manufacturers instructions.Primary system: Top 2 layers of 16mm Fyrechek plasterboard screw fixed to furringchannels at maximum 200 centres. Furring channels shall be fixed 600 centresclipped to Primary rails at 1200 centres. Primary rails shall be fixed at 1200 centressuspended from concrete soffit by suspension rod system.Secondly system: Bottom 2 layers of 16mm Fyrechek fixed to furring channel of600mm centers screw fixed through to Primary System
Stop and set flush all joints, stagger plasterboard joints 200mm minimum.
1.14 Fire Seal
Fire Seal all penetrations through fire rated floor and walls with flexible water basedgunnable sealant for fire resistant sealing of joints and service penetrations, up to 4hour FRL when tested to AS 1530 part 4.Product to be similar and equal to Fyreguard - Fyre Seal Mastic.Install as recommended by manufacturer.
1.15 Smoke Seal
Smoke seal all penetrations through smoke rated floors and walls and ceiling withflexible gunnable sealant for smoke sealing of joints and penetrations up to 2 hoursto AS 1530 part 4.Product to be similar and equal to Fyreguard - Smoke Seal.Install as recommended by manufacturer.
1.0 CONSTRUCTION
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
A
GLADSTONE REGIONAL COUNCIL
GLADSTONE REGIONAL COUNCILJCTN
RR
400597
A01.01113 GOONDOON STREET, GLADSTONE03.09.12
COVER SHEET TENDER
113 GOONDOON STREET, GLADSTONE
A01.01 COVER SHEET AA01.02 GENERAL NOTES & SPECIFICATIONS AA02 EXISTING CONDITIONS AND DEMOLITION PLAN BA02.01 DEMOLITION STAGING PLAN AA03 PROPOSED FLOOR PLAN AA04 SETOUT PLAN AA05 REFLECTED CEILING PLAN AA06 FINISHES PLAN AA06.01 FEATURE CARPET PLAN AA07 WORKSTATION PLAN & DETAILS AA08.01 JOINERY COVER SHEET AA08.02 JOINERY PLAN AA08.03 JOINERY DETAILS & ELEVATIONS AA08.04 JOINERY DETAILS & ELEVATIONS AA08.05 JOINERY DETAILS & ELEVATIONS AA08.06 JOINERY DETAILS & ELEVATIONS AA09 ELEVATIONS AA09.01 TOILET DETAILS AA09.02 TOILET DETAILS AA09.03 TOILET DETAILS A
Rev. Date Chk DescriptionA 23.11.12 TENDER
2.0 FLOOR FINISHES
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepancies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
Refer to Finishes Schedule where necessary.
2.1 REMOVAL OF EXISTING FLOOR TREATMENTS & CARPET PROTECTION
Remove sections of existing floor finish to receive selected new sheet vinyl, new carpet,stone and tiled floor as indicated on documentation. Prepare existing substrate asrequired to allow for new floor finish as specified to AS/NZS 2455.1 or AS/NZS 2455.2
2.2 PREPARATION OF CONCRETE SLAB
Allow to screed concrete floor as required to achieve flush finish between differentfloorings and to allow for falls to all new & existing floor wastes as required.
2.3 JUNCTION BETWEEN FLOOR FINISHESProvide 3mm thick natural anodised aluminium strip at junctions of different floorfinishes.
All surfaces to be flush.
PVC & wide aluminium diminishing strips are only to be used in back of house (.i.e.store room door thresholds etc).
2.4 RESILIANT
Edges of sheets and tilesEnsure edges are firm, unchipped, machine-cut accurately to size and square to theface, and that tile edges are square to each other.UnderlaysHardboard: Standard hardboard Type RD, to AS/NZS 1859.4, manufactured specificallyas flooring underlay.Fibre cement sheet: To AS 2908.2, Type B, category 2 minimum.Synthetic sporting surfaces: to AS 3541.1CorkStandard: To BS 6826LinoleumStandard: To BS 6826RubberStandard: To BS 1711Polyvinyl chloride (PVC)Unback flexible sheet: To AS 2055.1Semi-rigid floor tiles: To AS 1889.1Flexible flooring, needle-loom felt backed: To BS 5085.1Flexible flooring, cellular PVC backed: To BS 5085.2
Contractor to sheet vinyl direct to concrete substrate to area nominated on SmithMadden Group DWG.
Seam weld joins where applicable with self coloured welding rods, cutting flush withvinyl surface.Allow to polish vinyl on completion of works.
2.5 CARPET
Product/Finish to be: Refer to Finishes Schedule
TolerancesStandard: To AS 1385
BatchingEnsure that carpet laid in a single area and of a single specified type, quality, colourand design, comes from one manufacturing batch and dye lot.
Insect resistanceInsecticide: Provide carpets and underlays composed entirely of materials eitherinherently resistant to insect attack, or treated against attack, including by moth andcarpet beetle, by application of insecticide to the yarn during the dyeing or scouringprocess.Standard: To IWS E-10
2.5.1 Underlays
StandardGeneral: To AS/NZS 2455.1
Soft underlayStandard: To AS 4288 (Int)Rubber: Heavy -duty vulcanised rubber, waffle pattern, with a backing of reinforcingfabric.Reinforcing fabric: Either hessian, spun nylon, or polyester.
2.5.2 Adhesives & Tapes
StandardGeneral: To AS/NZS 2455.1
AdhesivesGeneral: Compatible with the floor covering material, and suitable for bonding it to thesubfloor.
Hot-melt adhesive tapesCommercial grade glass fibre and cotton thermoplastic adhesive coated tape 60 mmwide on a 90 mm wide metal foil base and backed with silicon-coated release paper.
2.5.3 Substrate
StandardGeneral: To AS/NZS 2455.1 or AS/NZS 2455.2, as appropriate
Substrate preparationGeneral: Suitably prepare the substrate to receive the carpet installation, including thefollowing:
2.5.4 Feature Broadloom Carpet
Contractor to supply and install new feature carpet with new underlay direct doublestuck to concrete substrate as nominated on Smith Madden Group DWG.
2.5.5 Carpet Tiles
Product/Finish to be: Refer Finishes ScheduleTo be supplied by Contracter and laid in strict accordance with manufacturer’srecommendations.Refer to finishes schedule.
2.5.6 Tiling
Surface finish slip resistanceStandard: To AS/NZS 3661.1Required locations: To public and general areas unless otherwise scheduled.AS/NZS 3661.1
2.6.1 Adhesive
Tests: test the surfaces to determine the co-efficient of friction in accordance withAS/NZS 3661.1, Appendices A and B. Testing shall be carried out by an NATA-Maintenance: Provide recommendations for the future cleaning, care and maintenanceof the floor finishes as installed, to enable continued in-service compliance withregistered testing authority approved by the Superintendent. Submit the test certificatesto the Superintendent.GeneralStandard: To AS 2358PVA based adhesives
2.6.2 Mortar
MaterialsSand: Fine aggregate with a low clay content selected for grading.Cement type to AS 3972: GPWhite cement: Iron salts content less than or equal to 1%Off-white cement: Iron salts content less than or equal to 2.5%Lime: To AS 1672Water: To AS CA27Bedding mortarProportioning: Select proportions from the range 1:3 - 1:4 cement: sand to obtainMixing: To AS CA27
2.6.3 Waterproofing Wet Areas
ComplianceGeneral: Comply with the waterproofing of wet areas as required by the BCA and AS3740.
2.6.4 Tiling Generally
Ceramic tilingInstallation generally: To AS 3958.1, (and AS3740 for caulking).
2.6.5 Stone Tile
Supply and install new stone tiles as indicated on Smith Madden Group DWG.Product finish refer to finishes schedule
2.6.6 Vitrified Tile
Supply and install vitrified tiles as indicated on Smith Madden Group DWG...
Product finishes: Refer to finishes schedule.
2.6.7 Tanking
Supply and install tanking membrane to shower room over entire floor.Ensure all surfaces are dry and free from dust, oil etc. An all level drain shall beinstalled as per plumbing code and manufacturers instructions. All falls to 10mm permetre into drain. Prior to applying Emer-Clad in shower area prepare and prime thesubstrate in accordance with manufacturer’s surface preparation details.
Once completed, apply a fillet of Rallithane 810 polyurethane. Joint sealant should beapplied at the junction of the wall and floor (perimeter seal). A base coat of Emer-Cladshould be layered and a layer of polyester reinforcing fabric placed over all joints andwhere the walls and floors meet. Apply reinforcement over entire floor surface.
Apply multiple coats of Emer-Clad minimum 3, to achieve a dry film thickness of 500microns. Apply Emer-Clad to entire wall surface within shower recess to a height of1800mm and outside shower recess to a height of 150mm.
Water test membrane 48 hours after installation.
2.7 FEATURE RUG
To be supplied by Head Contractor.
Refer to Finishes Schedule
2.8 ACCESS FLOOR
Access floor contractor to supply and install access floor as nominated on Smith MaddenGroup DWG
Access floor Tasman TC 1000S consisting of interchangeable 600 x 600mm panelssupported and captured by bolted stringers to adjustable pedestal assemblies. Panelshall be high tensil top sheet welded to a die formed steel pan. Provided with factorybonded anti-static high pressure laminate. Understructure system shall consist of apedestal band and head assemblies.Pedestals will be provided with a means of levelling and looking at a selected heightwhich prevents vibration displacement.Allow for services outlets to accommodate power communications and data signedcables. Also allow for cutouts for Air Grilles for underfloor air-conditioning as required.The access floor contractor shall provide standard ramp, tactile indicators and handrailas located on drawing and to AS 1428.
3.0 WINDOW TREATMENTS
Refer to Finishes Schedules when necessary
3.1 MODIFY EXISTING BLINDS
Modify existing blinds to suit revised layout. Allow to cut existing blinds and supply newwhere new partitions butt up against external windows.
3.2 INTERNAL GLAZING FILM
Supply & install adhesive film to glazing as indicated on Smith Madden Group DWG.
3.3 PERIMETER BLINDS
Supply & install blinds to perimeter/ internal glazing as indicated on Smith MaddenGroup DWG and Schedule.
Electrical connection to manufacturers recommendation.
3.4 BLACKOUT BLINDS
Supply & install motorised blackout blinds as indicated on Smith Madden Group DWGProduct/Finish: As per SMG schedules.
All trades are to work in accordance with current relevant State Regulations,industry agreements and codes.Include messing facilities for all trades for duration of project.Maintain a site register of all equipment and personnel working on the siteProvide a full time first aid officer (minimum Level 2first aid qualification) for duration of project.Final clean on completion to include perimeter glazing, toilets and core area - as applicable.Coordination of smoke detector isolation/reinstatement for all trades when required.Coordination of access for all trades on site.
5.0 HYDRAULICSCoordination of subtrades on site (coordination fee to be negotiated with successful headcontractor).NO SMOKING on siteGeneral Adherence to Tenancy Guidelines/Fitout Rules
The hydraulic services contractor shall co-ordinate with the builder, mechanical, electricaland fire sprinkler services contractors.
5.1 GENERAL
All work shall be carried out to AS3500 and the regulations and requirements of allauthorities having jurisdiction over any part of the works.
New sewer drains, wastes and vents shall be UPVC SWV grade to AS3500. Waste pipe tobe clipped at 500mm centres as per hot waste and discharge requirements and provisionfor expansion to be made.
Hot and cold water service shall be copper tube type B to AS3500
Allow for all Jump-Ups, Risers, Altering Pipes, Inspection Openings fittings as required byAS3500.
Fix piping hard against underside of slab using minimum gradients to maximise ceilingspace height.
Install approved fire collars where plastic piping passes through fire rated floors andwalls.
All hot water piping to be fully thermally insulated.
All penetrations through wall and floor slabs by hydraulics contractor.
All exposed pipes and tundishes to be chrome.
Refer to architectural schedules for tap and fixture types and details.
5.2 PLUMBING & DRAINAGE WORKS
Supply and installation of plumbing inclusive of hot and cold water supply, associatedpipework and wastes.
5.3 HOT WATER SERVICES
Supply and install of Hot Water Unit.Refer Appliances Schedule
5.4 BOILING/CHILLED WATER UNIT
Supply and install Boiling/Chilled Water Unit as per Smith Madden Group.
5.5 FIXTURES/FITTINGS
Supply and installation of fixtures as listed on the Appliances Schedule
5.6 WHITEGOODS
Supply and installation of dishwasher as listed on the Appliance Schedule
5.7 CUT & SEAL
Cut and seal of existing hydraulic services (existing surfaces to be made good).
6.7 SEPARATE SWITCHING
Separate switching to be provided as indicated on the Smith Madden Group/Engineers DWG.
6.8 EXIT/EMERGENCY
Exit and Emergency lighting to be provided in accordance with statutory requirements.
6.9 SUBMETERING OF ELECTRICAL APPLIANCES
Submetering of power to be supplied as required. Allow for coordination with building ownerrepresentative and power supply authority.
6.10 INSTALLATION OF ELECTRICAL APPLIANCES
Installation of the following electrical appliances/whitegoods as per the appliance schedule.
6.11 CABLING/OUTLETS
Supply/installation of electrical outlets as noted - Refer to Smith Madden Group/EngineersDWG.Allow single phase cabling unless otherwise noted.
6.12 DEDICATED POWER
Dedicated power to be provided as identified on therelevant Smith Madden Group/Engineers DWG & schedule.
6.13 UPS
Supply and connection to UPS as required.
6.14 HARD/SOFT WIRING
Workstations to be wired as per notations on the relevant Smith Madden Group/EngineersDWG.
6.15 TESTING/AS-BUILT CERTIFICATION
Allow to test and tag all electrical leads/equipment being used on site for all trades forduration of projectAllow to provide temporary power board/s for duration of project including earth leakageprotection.Allow to label all GPOs.
7.1 DEMOLITION
As required to make safe
7.2 CABLING/OUTLETS - DATA & VOICE
Supply/installation of data and voice cabling/outlets as noted. Refer to Smith Madden GroupDWGCabling type - CAT6 unless otherwise noted.Data termination type - RJ45 unless otherwise noted.Voice termination type - RJ45.Fibre Optic Cabling as per standards
7.3 COMMUNICATIONS RACK
Supply/installation of cabling outlets. Refer to Smith ‘Madden Group /Engineers DWG
7.4 COMPUTER ROOM
Supply/installation of cabling outlets. Refer to Smith ‘Madden Group/Engineers DWG
7.5 FLYLEADS & PATCH LEADS
Allow for Flyleads at one metre in length as requiredAllow for patch leads at one metre in length as requiredAllow to patch from rack to panels
Supply and install security as noted.
8.1 SUPPLY & INSTALLATION
Electronic security to match and link to existing, refer to Door Schedule. Head contractor toprovide supports/fixing of electronic fixtures as required. Testing, labelling andcommissioning of system on completion.
8.0 ELECTRICAL SECURITY
9.0 FIRE SERVICES9.1 DEMOLITION
Adjust fire detection/suppression system to suit demolition of existing partitions.
9.2 SPRINKLERS
Refer to SMG DWG for reference and notes.· The fire services contractor shall co-ordinate with the builder, mechanical,hydraulic and electrical services contractors.· This drawing represents an existing sprinkler head layout and therefore doesnot indicate proposed layout for pipework routes, bends, offsets, etc. Which shall beincluded by the fire services contractor at the time of tender· All new sprinkler heads shall match existing heads used in the tenancy on thisfloor, except for new flush mounted type where shown.· The contractor shall check the location of all in ceiling sprinkler heads andadvise of any discrepancies.· The contractor shall allow for the supply and installation of extra on ceilingsprinkler heads as required.
9.3 MODIFICATION TO EXISTING FIRE SERVICES
· All works shall be in accordance with as 2118 and certifiers requirements forordinary hazard classification.
9.4 FIRE HOSE REELS, HYDRANTS, EXTINGUISHERS
Existing sprinkler heads if required to be deleted are to be reused where new sprinklerheads are required where suitableRefer to Smith Madden Group/Engineers DWG for reference and notes.Supply and install equipment as indicated in Smith Madden Group/Engineers drawings
9.5 FLUSH MOUNTED SPRINKLER HEADS
Supply and install sprinklers to flush plasterboard area as indicated on drawings
9.6 SMOKE DETECTORS
Supply and install and modify smoke detectors in accordance to Australian Standardsand Certifiers.Testing and commissioning of system on completion.
2.0 FLOOR FINISHES 4.0 OTHER BUILDING WORKS
6.0 ELECTRICAL, LIGHTING & POWER
The electrical contractor shall co-ordinate with the Builder, Mechanical Hydraulic and FireProtection Service contractors.
Reuse existing fittings where shown on floor plans or to be deleted where suitable.
All redundant equipment and wiring shall be removed. Notify consultant and seekinstruction in case where demolition works affect existing equipment and cabling to bereused.
The contractor shall make an allowance in tender to locate fittings to suit new andexisting services in ceiling space.
Refer to architectural reflected ceiling drawings for all downlight setouts on newplasterboard ceiling areas.
Supply and install EWIS speakers in accordance with AS 2220. Speakers shall be flushmounted on ceiling.
6.1 DEMOLITION
As required to make safe.
6.2 RELOCATION
Relocation of existing typical light fittings to suit partition layout. Refer to relevant SmithMadden Group DWG.
6.3 TYPICAL LIGHTS
Supply/Installation of selected typical light fittings to suit partition layout. Refer torelevant Smith Madden Group DWG.
6.4 DOWNLIGHTS
Supply/installation of selected low voltage downlights to areas as noted.
Supply/installation of dimmers to downlights within all meeting rooms - Refer to SmithMadden Group/Engineers DWG & schedule.schedule.
6.5 FEATURE LIGHTS
Supply/installation of selected feature lighting as indicated. Refer to Smith Madden GroupEngineers & schedule.
6.6 BANK SWITCHING
Bank switching to be located as indicated on Smith Madden Group/Engineers DWG.
6.0 ELECTRICAL, LIGHTING & POWER
7.0 ELECTRICAL COMMUNICATIONS
10.0 MECHANICAL
14.0 SIGNAGE
10.0 MECHANICAL
· Mechanical contractors shall coordinate with existing ceiling space services.· The contractor shall check the location of all in ceiling ductwork andequipment and advise of any discrepancies.· Make allowance in tender for any discrepancies for diffusers to be located onnearest ceiling tile where ceiling space obstructions prevent diffuser be located onceiling tile as shown on the ceiling plan.· The mechanical services contractors shall co-ordinate with the builder, FireSprinkler, Hydraulics and Electrical Services contractors.
· All penetrations, holes and damage in existing surfaces which are to remainshall be made good. Refer to architectural drawings and specification for details offinishes and quality of work.· All ductwork to be installed in ceiling space unless noted otherwise.
10.1 MODIFICATION TO EXISTING MECHANICAL SERVICES
Modification of existing supply air/return air outlets to suit revised partition layout.Refer to Smith Madden Group /Engineers DWG.
10.2 NEW MECHANICAL SERVICES
Refer to Smith Madden Group/Engineers DWGS
10.2.1 LINEAL SLOT DIFFUSERS
Supply/installation of linear slot diffusers to flush plaster ceiling as required. Refer toSmith Madden Group/Engineers DWG.
10.3 EXHAUST SYSTEM
Supply/installation of exhaust systems as noted. Refer to Smith Madden Group/Engineer DWG
10.4 SUPPLEMENTARY AIR CONDITIONER
NOTE THIS COSTING IS TO BE SHOWN SEPARATELY
Allow to supply and install to the areas as identified on the Smith MaddenGroup/Engineer Dwgs
Provide detail on proposal (eg. Area required type of unit, operation of unit.
10.5 AIR TRANSFER GRILLES
As requiredPreference is to not have air relief grilles located in doors (undercut doors ifnecessary).
Balance and commission of system on completion.
11.0 SCREENS & SYSTEM FURNITURE
Supply/install the workstation system as identified in Smith Madden Group DWG andWorkstation Schedule.
11.1 WORKSTATION SYSTEM
Refer to Workstation Schedule for worktop finish, screen height and storagerequirements and accessories.
11.2 GPO KITS
Location on screens - Refer to Smith Madden Group DWG.Wiring as per Smith Madden Group workstation schedule.
Allow for data / voice cutouts, (GPO kits to be supplied cabled by cabling contractor).Refer to Smith Madden Group DWG.Supply/install cable tidies where required.Supply and install power blades between workstation screen and ceiling. Refer toSmith Madden Group DWG.
11.3 RELOCATION OR RECONFIGURATION OF EXISTING
Relocation/reconfiguration of existing workstations on/off site as required. Allow fornew components as required to make up new workstation layout.
Refer to Smith Madden Group DWG.
Signs - design and use to AS 2342Public information signs - to AS 2899Safety signs - design and use to AS 1319Aluminium Plate for engraving: Alloy & temper designation 6063-0For casting: To AS 1874Stainless SteelSurface finish designation 4 (general purpose polished)PlasticsUPVC sheet: Semi-rigid sheet to AS 2324Rigid cellular polystyrene: To AS 1366.3 class VH for cut-out shapes
14.1 RELOCATION OF EXISTING SIGNAGE
Relocate as per Smith Madden Group instruction.
14.2 SIGNAGE TO RECEPTION
Refer to Smith Madden Group DWG.
12.0 JOINERY
Refer to Joinery Cover Sheet.
13.0 LOOSE FURNITURE & STORAGE
Relocation/reconfiguration of existing joinery on site as required.
Generally supply and install loose items & storage units as shown on Smith MaddenGroup DWG & Loose Furniture Schedule.
15.0 WHITEGOODS & APPLIANCES
Supply whitegoods as nominated in the Appliances Schedule.
16.0 LIFT CARS
Construction as per AS1735.
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A01.02113 GOONDOON STREET, GLADSTONE03.09.12
GENERAL NOTES & SPECIFICATIONS TENDERRev. Date Chk Description
A 23.11.12 TENDER
UP
UP
UPDN
EXISTING PARTITION TO BE DEMOLISHED
NEW PLASTERBOARD PARTITION
EXISTING CORE WALLS & PARTITIONS TO REMAIN
PARTITION LEGEND
RETAIN EXISTINGFLOOR MAT
NOT IN SCOPE
DEMOLITION NOTES
1. DEMOLISH ALL WALLS,FLOORS,CEILINGS &FIXTURES AND MAKE GOOD AS REQUIREDREADY FOR NEW FITOUT.
2. ALL EXISTING BASE BUILD WALLS HAVETEXTURED STIPPLE FINISH, MAKE GOOD TOMATCH ADJACENT WALL FINISH.
3. TENDERER MUST VISIT SITE DURING TENDERPERIOD AS THERE ARE VARYING FLOORFINISHES WITHIN TENANCY.
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 100
BGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A02113 GOONDOON STREET, GLADSTONE03.09.12
EXISTING CONDITIONS AND DEMOLITION PLAN TENDER
1 : 100A021 GROUND FLOOR_EXISTING & DEMO PLAN
1 : 100A022 FIRST FLOOR_EXISTING & DEMO PLAN
0 5 10 m 1 : 100LOCATION
Revision Date AmendmentsA 23.11.12 TENDER
B 02.1.12 TENDER - DEMOLITION STAGING A02.01 ADDED
IMPORTANT ! - REFER TO DRAWING DEMOLITION STAGING PLAN
B
UP
UP
UP
UP
UP
UP
DN
DN
RETAIN EXISTINGFLOOR MAT
RETAIN EXISTINGFLOOR MAT
NOT IN SCOPE
NOT IN SCOPE
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 100
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A02.01113 GOONDOON STREET, GLADSTONE03.12.12
DEMOLITION STAGING PLAN TENDERRevision Date Amendments
A 02.1.12 TENDER - DEMOLITION STAGING A02.01 ADDED
1 : 100A02.011 GROUND FLOOR_EXISTING & DEMO STAGE 1
1 : 100A02.012 GROUND FLOOR_EXISTING & DEMO STAGE 2
1 : 100A02.013 FIRST FLOOR_EXISTING & DEMO STAGE 1
1 : 100A02.014 FIRST FLOOR_EXISTING & DEMO STAGE 2
0 5 10 m
NOTE - NO ADDITIONAL STAGE 2 FIRST FLOOR DEMOLITION
B B B
RB RB RB
SB SB SB
VB VB VB
HB HB HB
UP
UP
UPDN
EXISTING PARTITION TO BE DEMOLISHED
NEW PLASTERBOARD PARTITION
EXISTING CORE WALLS & PARTITIONS TO REMAIN
PARTITION LEGEND
INDICATES BLOCK OUT BLINDS
INDICATES EXTENT OF WORKS
INDICATES ROLLER BLINDS
INDICATES SLIM BLINDS
INDICATES VERTICAL BLINDS
GENERAL LEGEND
INDICATES HORIZONTAL BLINDS
DENOTES ROOM OR AREA NUMBER
DENOTES FLOOR FINISH
DENOTES NEW DOOR NUMBER
DENOTES EXISTING DOOR NUMBER
DENOTES JOINERY NUMBER
DENOTES CEILING HEIGHT
DENOTES WORKSTATION NUMBER
DENOTES WALL TYPE
DENOTES SCREEN TYPE & FABRIC FINISH
DENOTES JOINERY/WALL FINISHES
DENOTES ALIGNMENT
NOTE: LEGEND TO BE READ IN CONJUNCTION WITH SCHEDULES.
J01
A WS01
?
S1
ALIGN
L1
101
CA01
D01
EXD01
CH2700
BREAKOUT
STORE
S/B ELEC
FHR
2HR FIRERATED
ENTR
Y BO
ARD
/IN
TER
CO
M
ART
INST
ALLA
TIO
N
LARGE MEETINGG.03
OFFICE 3G.05
KITC
HEN
ETTE
G.0
7
PWDG.10
FWCG.09
MWCG.08
QUIET RMG.11
CLIENT MEETINGG.13
CLIENT MEETG.14
CUSTOMER WAITINGG.15
STOREG.17COMPACTUS
G.24
OFFICE 7G.23
OFFICE 5G.21
OFFICE 4G.20COMMS
G.25
FHR
AMBULANT
AMBULANT
QUIET RMG.19
HOT DESKS
SMALL MEETINGG.04
109LOADINGBAY
OFFICE 1G.01
OFFICE 2G.02 C2
C2
C2
C2
C2
C2
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C6C6ST1
T3
C5T4
C5
C2
C1C1
ST2 ST2 ST2 ST2 ST2
ST2 ST2 ST2 ST2 ST2
ST2
ST1
ST1ST1
C2
ST1
C2
C2
C2
ST1
ST1ST1
C2
C2
C2
C2
C2
C2
ST3
C2
ST3
C2
ST3
C2
ST3
C2
ST3
C2
ST3
C2
ST3
C2
ST3
ST1ST1
ST1ST1
C2
ST3
C2
ST3
C2
ST3
C2
ST3
C2
ST3
C2
ST3
C2
ST3
C2
ST1
C2
C2
C2
C2
ST1
ST1ST1
C2C2
C2
C2C2
C2
C2
C2
C2
C2
C2
C2
C2C2
C2 C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
ST1
ST1
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
T5
C7
C7
C7 C7
T5
C7
C7
C7
T3
C5
T3
C3C3C3C3
C3C3C3C3
ST1
C2 C2
C5
T5
C7
C7
C7
C7
C2C2
C2
C2
C2
C2
C6C6
C6 C6
C6 C6
C2
C1C1
C2
C1C1
C2
C1C1
C2
C1 C1
C2
C1C1
C2
C1 C1
OPEN OFFICEG.26
PRINT 1G.06
BREAKOUTG.12
STAFFG.16
OPEN OFFICEG.27
OPEN OFFICEG.28
BREAKOUTG.29 OPEN OFFICE
G.30
OPEN OFFICEG.31
T2
T2
WSC
WSCWSC WSC WSC
C2
WSD
T2
T4
T3
C4 C4
WSD
C4 C4
T1 T1 T1
T6T6T6T6
C2
ST3 ST3
ST4ST4ST4ST4ST4ST4ST4ST4ST4ST4ST4ST4ST4ST4ST4
C1C1C1
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3ST3
ST3
ST3ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3ST3
ST3 ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
ST3
C4
C4
C1C1
ST3
T5
T5
C4
1A09.01
WSE WSE
ST2 ST2 ST2ST2 ST2 ST2 ST2 ST2
ST2
ST2ST2ST2ST2ST2
FHR
ST1 ST1
ST1
ST1
ST1
ST1
OFFICE 6G.22
COMMS ROOM
2765 COS
CO
MM
S R
OO
M
3073
CO
S
PRINT 2G.18
C8
LUNCH ROOM1.03
WC
WC MALE TOILET1.01
FEMALE TOILET1.02
SHOWER
UR
NIN
ALS
SHOWER
NOT IN SCOPE
C7
C7C7
C7 C7
C7C7
C7
C4
T3
T5 T5
C7
C7C7
C7
T5C7
C7C7
C7
T5
C3 C3 C3
C3C3C3
C5
C4
T2
1A09.02
Sim4
A09.03
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 100
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A03113 GOONDOON STREET, GLADSTONE03.09.12
PROPOSED FLOOR PLAN TENDER
1 : 100A031 PROPOSED FLOOR PLAN
1 : 100A032 FIRST FLOOR PROPOSED PLAN
0 5 10 m
1 : 100A033 FIRST FLOOR REAR TOILETS PROPOSED PLAN
Revision Date AmendmentsA 23.11.12 TENDER
UP
UP
UP
DN
THIS AREA TOHAVE NOOBSTRUCTIONS
IN ACCORDANCE WITHAS 1428.1 - 2009
FOR
CLE
ARAN
CE
RE
FER
TO
DW
G A
10
FOR CLEARANCEREFER TO DWG A10
FACE OF DOOR
WHERE DOUBLEDOORS ARE USED,THE 850MM MINIMUMCLEAR OPENINGSHALL APPLY TO THEACTIVE LEAF
920
850 MM MIN. CLEAR OPENINGFOR CLEARANCE
REFER TO DWG A10
FOR
CLE
ARAN
CE
RE
FER
TO
DW
G A
10
THIS AREA TOHAVE NOOBSTRUCTIONS
920 MIN DOOR WIDTHREFER DOOR SCHEDULE FOR
DOOR WIDTH
OFF CENTRE LINEOF CEILING GRID
CENTRE LINEOF CEILING GRID
WINDOW MULLION
SETOUT REFERENCES
SETOUT OF PARTITION TO BE CENTRE LINE OFCEILING GRID OR CENTRE OF TILE OR CENTRE OFWINDOW MULLIONS EXCEPT WHERE OTHERWISEDIMENSIONED OR REFERRED TO A DETAIL.
1898 3090 3090 6073 3628 3077 2972 3653 2800 1720 2485 3309 5500
3945
4525 CO
S
4285
3045 3090 3090 3090
3645
943
D04 D05
D01
D07
D08
D09
D10
D12D13 D14
EX
D23 D22 D21 D20D24
EX
EX
EX
EXEXEX
D12
EX
P1
P1
P1
P1
P1
P1
P1 P1
P1
P1
P1
P1
G1
P1
G1 G1 G1
P1
P1
P1P1
P1
P1
ALIGN
ALIGN
ALIG
N
LARGE MEETINGG.03
OPEN OFFICEG.26
OFFICE 3G.05
KITC
HEN
ETTE
G.0
7
PWDG.10
FWCG.09
MWCG.08
QUIET RMG.11
CLIENT MEETINGG.13
CLIENT MEETG.14
CUSTOMER WAITINGG.15
STOREG.17
COMPACTUSG.24
OFFICE 7G.23
OFFICE 5G.21
OFFICE 4G.20
COMMSG.25
D02 D03
ALIGN ALIGN ALIGN
D06
D11
D16
D17
OFFICE 1G.01
OFFICE 2G.02
SMALL MEETINGG.04
PRINT 1G.06
P2
9159
EX
P1 P1
G1 G1 G1
110 110
OPE
RAB
LE W
ALL
140 110 110
P1
P1
440
400
110
110
110G1 G1 G1 G1 P1
P1
G1
P1
QU
IET
RO
OM
2545
110600
G1 P1P1 G1
600
110 110
600
G1
ALIGN
ALI
GN
110
P1
QUIET RMG.19
BREAKOUTG.12
STAFFG.16
OPEN OFFICEG.27
OPEN OFFICEG.28
BREAKOUTG.29
OPEN OFFICEG.30
OPEN OFFICEG.31
G1
P1
P1
P1
*
ALLOW SUITABLEDEPTH FOR FHR
*
ALLOW SUITABLEDEPTH FOR FHR
ALIGN ALIGN
P4
ALIGN WITH BULKHEAD
D30
EX EX
D29
D32
740
110
CO
S
1075
FHR
COS
3550
1740
1900
CLR900
CLR900
350
ALIGN EX
OFFICE 6G.22
2995
D19
COS
2765
2995
1000 P1
P1
110
P1
G1
1785
CO
S
1290
SUITABLEDEPTH FOR FHR
D25 D26D27
EX
EXEX
EX EX
EX
EX
ALIGNALIGN
1445 1935ALIGN
WC
WC
FEMALE TOILET1.02
SHOWER
MEETING/PING PONG ROOM
MALE TOILET1.01
UR
NIN
ALS
SHOWER
LUNCH ROOM1.03
NOT IN SCOPE
P3
P3
P3
P3
D28
130
CO
S
2655
110
ALLOW FOR PROPRIETARY WATERPROOF MEMBRANE TO WALLS &FLOOR OF SHOWERS
905
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
As indicated
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A04113 GOONDOON STREET, GLADSTONE03.09.12
SETOUT PLAN TENDER
1 : 20DOOR CLEARANCE - SWING DOOR
1 : 100A041 GROUND FLOOR_SETOUT PLAN
1 : 100A042 FIRST FLOOR_SETOUT PLAN
PARTITION LEGENDTYPE DESCRIPTION HEIGHT MATERIAL FRAMING COMMENT 1 COMMENT 2 COMMENT 3 INSULATION SKIRTING NOTE
G1 FULL HEIGHT GLAZEDPARTITION WALL TO AS 1288
FROM F.F.L. TO UNDERSIDE OFSUSPENDED CEILING
10.38mm lAMINATEDCLEAR GLASS
SELECTEDALUMINIUMFRAMES
REFER TOSCHEDULES FORFINISH TOALUMINIUMFRAMES
REFERELEVATIONS FORDETAILS
N/A N/A
P1 FULL HEIGHTPLASTERBOARD PARTITION
FROM F.F.L. TO UNDERSIDE OFSUSPENDED CEILING
1x13mm GYPSUMPLASTERBOARD EACHSIDE
64mm STEELSTUDS @ 600mmCTRS
STAGGER JOINTSEACH SIDE. TAPE& SET FINISH
50mm ACOUSTICINSULATIONBATTS WITHINWALL
100m ALUMINIUM
P2 FULL HEIGHT 2 HOUR FIRERATED PLASTERBOARDPARTITION
FROM F.F.L. TO UNDERSIDE OFSUSPENDED CEILING
2x13mm CSR FYRCHEKPLASTERBOARD EACHSIDE
64mm STEELSTUDS @ 600mmCTRS
STAGGER JOINTSEACH SIDE. TAPE& SET FINISH
FOLLOW CSR GUDELINES TOACHIEVE FRL
50mm ACOUSTICINSULATIONBATTS WITHINWALL
100m ALUMINIUM
P3 FULL HEIGHT FIBRE CEMENTPARTITION
FROM F.F.L. TO UNDERSIDE OFSUSPENDED CEILING
1x FIBRE CEMENTSHEET EACH SIDE
64mm STEELSTUDS @ 600mmCTRS
STAGGER JOINTSEACH SIDE. TAPE& SET FINISH
50mm ACOUSTICINSULATIONBATTS WITHINWALL
100m ALUMINIUM
P4 LOW HEIGHTPLASTERBOARD WALL
FROM F.F.L. TO 1200 AFL 1x13mm GYPSUMPLASTERBOARDVISIBLE SIDE
TO SUIT 200mmWIDE
STAGGER JOINTSEACH SIDE. TAPE& SET FINISH
N/A 100m ALUMINIUM
P6 BULKHEAD FROM F.F.L. TO UNDERSIDE OFSLAB
1x13mm GYPSUMPLASTERBOARDVISIBLE SIDE
51mm STEELSTUDS @ 600mmCTRS
- 50mm ACOUSTICINSULATIONBATTS WITHINWALL
N/A
0 5 10 m
Revision Date AmendmentsA 23.11.12 TENDER
CH3000
CH3600
CH3000
CH2700
CH2700
SET PLASTERBOARD FACE TO ALL BULKHEADS
LARGE MEETINGG.03
OPE
N O
FFIC
EG
.26
OFFICE 3G.05
KITCHENETTEG.07 PWD
G.10
FWCG.09
MWCG.08 QUIET RM
G.11
CLIENT MEETINGG.13
CLIENT MEETG.14
CUSTOMER WAITINGG.15
STOREG.17
COMPACTUSG.24
OFFICE 7G.23
OFFICE 5G.21
OFFICE 4G.20
COMMSG.25 QUIET RM
G.19
SMALL MEETINGG.04
OFFICE 1G.01
OFFICE 2G.02
PRINT 1G.06
BREAKOUTG.12
STAFFG.16
OPEN OFFICEG.27
OPEN OFFICEG.28
BREAKOUTG.29
OPEN OFFICEG.30
OPEN OFFICEG.31
OFFICE 6G.22
EXISTING CEILING TO REMAINALLOW TO PATCH & PAINT TONEW PARTITION ANDLIGHTING LAYOUT
NOT IN SCOPE
LUNCH ROOM1.03
WC
WCMALE TOILET
1.01
FEMALE TOILET1.02
SHOWER
SHOWER
ACOUSTIC BAFFLES IN CEILING SPACE
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 100
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A05113 GOONDOON STREET, GLADSTONE03.09.12
REFLECTED CEILING PLAN TENDER
1 : 100A051 GROUND FLOOR_REFLECTED CEILING PLAN
1 : 100A052 FIRST FLOOR_REFLECTED CEILING PLAN
0 5 10 m
Revision Date AmendmentsA 23.11.12 TENDER
UP
UP
UPDN
FINISHES NOTES
ALL NEW & EXISTING WALLS & COLUMNS WITHIN THE TENANCYTO BE PT1 UNLESS OTHERWISE NOTED.
ALL NEW & EXISTING DOORS TO BE PAINTED.
ALL NEW WALLS TO HAVE 100MM ANODISED ALUMINIUM SKIRTING.
ALUMINIUM ANGLE TO ALL CHANGES IN FLOOR FINISHES.
LARGE MEETINGG.03
OPEN OFFICEG.26
OFFICE 3G.05
KITCHENETTEG.07
PWDG.10
FWCG.09
MWCG.08 QUIET RM
G.11
CLIENT MEETINGG.13
CLIENT MEETG.14
CUSTOMER WAITINGG.15
STOREG.17
COMPACTUSG.24
OFFICE 7G.23
OFFICE 5G.21
OFFICE 4G.20
COMMSG.25
V1
FT1
V1
RETAIN EXISTINGFLOOR MAT
ALL STEPS TO HAVE NEWTREDSAFE NOSING
V1
PT2
A091
QUIET RMG.19
SMALL MEETINGG.04
OFFICE 1G.01
OFFICE 2G.02
PRINT 1G.06
BREAKOUTG.12
STAFFG.16
OPEN OFFICEG.27
OPEN OFFICEG.28
BREAKOUTG.29
OPEN OFFICEG.30
OPEN OFFICEG.31
A094
A09
3
EXTENT OF PT2
PATCH & PAINT EXISTINGSHOP FRONT ROOM
OUTSIDE RL 19.901INSIDE RL 19.921ALLOW TO SCREEDCORRIDOR TO LEVELTHE FLOOR
OFFICE 6G.22
V1
V1
EXISTING FLOOR TO REMAIN EXISTING FLOOR
TO REMAIN
REFER TO DRAWING FEATURECARPET PLAN A06.01 AND PAGE 26FINISHES SCHEDULE FOR CARPETTILE DETAILS
WC
WC
FEMALE TOILET1.02
SHOWER
MEETING/PING PONG ROOM
MALE TOILET1.01
UR
NIN
ALS
SHOWER
LUNCH ROOM1.03
NOT IN SCOPE
FT1
V1
V1
ALL STEPS TO HAVE NEWTREDSAFE NOSING
ALL STEPS TO HAVE NEWTREDSAFE NOSING
A09
5
6 REFER TO DRAWINGFEATURE CARPET PLANA06.01 AND PAGE 26FINISHES SCHEDULE FORCARPET TILE DETAILS
CARPET
ALUMINIUM ANGLERAMP UP TO LEVEL
TO ENSURE FLUSH FLOOR LEVEL
VINYL TILECARPET / VINYL
ALUMINIUM ANGLERAMP UP TO LEVELTO ENSURE FLUSH FLOOR LEVEL
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
As indicated
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A06113 GOONDOON STREET, GLADSTONE03.09.12
FINISHES PLAN TENDER
1 : 100A061 GROUND FLOOR_FINISHES PLAN
1 : 100A062 FIRST FLOOR_FINISHES PLAN
1 : 2A063 CARPET TO VINYL TRANSITION
1 : 2A064 CARPET/VINYL TO TILE TRANSITION
0 5 10 m
Revision Date AmendmentsA 23.11.12 TENDER
NOTE 1 - THIS DRAWING MUST BE PRINTED IN FULLCOLOUR TO BE CORRECTLY COMPREHENDED
NOTE 2 - REFER TO FINISHES SCHEDULE FOR MOREINFORMATION
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
As indicated
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A06.01113 GOONDOON STREET, GLADSTONE03.09.12
FEATURE CARPET PLAN TENDER
NOT TO SCALEA06.011 FEATURE CARPET PLAN
DO NOT SCALE
Revision Date AmendmentsA 23.11.12 TENDER
UP
UP
UP
LARGE MEETINGG.03
OPEN OFFICEG.26
OFFICE 3G.05
KITCHENETTEG.07
PWDG.10
FWCG.09
MWCG.08
QUIET RMG.11 CLIENT MEETING
G.13
CLIENT MEETG.14
CUSTOMER WAITINGG.15
STOREG.17
COMPACTUSG.24
OFFICE 7G.23
OFFICE 5G.21
OFFICE 4G.20
COMMSG.25
WSA
WSA
WSA
WSA WSA
WSA
WSA
WSA WSA
WSA
WSA WSA
WSA
WSA
WSA
WSA
WSA
WSA
WSB WSB
WSB
WSB
WSB WSB
WSB
WSB
WSB WSB
WSB
WSB
WSB
WSB
WSB WSB
WSA
WSA
WSA WSB
WSB
WSB
WSB WSB
WSB
WSB
WSBWSA
WSA
WSA
WSB WSB
WSB
WSB WSB
WSB
WSB
WSB
WSB
WSB WSB
WSB
WSB
WSB
QUIET RMG.19
SMALL MEETINGG.04
OFFICE 1G.01
OFFICE 2G.02
PRINT 1G.06
BREAKOUTG.12
STAFFG.16
OPEN OFFICEG.27
OPEN OFFICEG.28
BREAKOUTG.29
OPEN OFFICEG.30
OPEN OFFICEG.31
1582 2467
23002300 2300 2300
DESKINFILL
WSB
WSD
WSE WSE
WSCWSC
DESKINFILL
DESKINFILL
DESKINFILL
COS
2395
WSC WSCWSC WSC
WSC
OFFICE 6G.22
WSD
COS
2995
1050
1860
ALIGN ALIGN
1750
1750
1750
1750
1585
1585
130017
15
1915
1800
750
WORKSTATION TYPE WSA
2100
750
WORKSTATION TYPE WSB
750
WORKSTATION TYPE WSC
750
2100
1800
COS - TO FIT WITHIN ROOM
2395 TO 2995
600
WORKSTATION TYPE WSD
3000
750
WORKSTATION TYPE WSE
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
As indicated
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A07113 GOONDOON STREET, GLADSTONE03.09.12
WORKSTATION PLAN & DETAILS TENDER
1 : 100A071 GROUND FLOOR_WORKSTATION PLAN
0 5 10 m
WORKSTATIONCOUNT
NO. QTY
WSA 25WSB 39WSC 7WSD 2WSE 2
1 : 50A072 WORKSTATION LEGEND
Revision Date AmendmentsA 23.11.12 TENDER
JOINERY NOTES
FINISHES NOTES & SCHEDULE
Site conditions and dimensions to be verified by the contractor prior tocommencement of works. Discrepancies to be reported to Smith Maddenrepresentative for verification.
Manufacture and install all joinery items as shown on Smith Madden Group DWG.
Contractor should refer to Smith Madden Group Drawings to determine relevant joineryreference number and hence locate relevant joinery and detail drawings.Refer to Joinery Schedule and Finishes ScheduleContracter to produce shop drawings, where indicated in journey schedule for SMGapproval.
TIMBER FIXTURES
Joinery timberSeasoned hardwood: To AS 2796Radiata pine: To AS 1493 or AS 1497, as applicableCypress pine: To AS 1810Australian grown conifers, other than radiata pine and cypress pine: To AS 1786PlywoodInterior use generally: To AS 2270Interior use exposed to moisture: To AS 2271ParticleboardStandard: To AS/NZS 1859.1Grade: High moisture resistance (HMR) grade
Melamine overlaid particleboard overlaid on both sides with low pressure melamine.Medium density fibreboard (MDF)Standard: To AS/NZS 1859.3Grade: High moisture resistance (HMR) gradeMelamine overlaid medium density fibreboard: medium density fibreboard overlaid onboth sides with low pressure melamine.Decorative overlaysStandard: To AS/NZS 1859.3Decorative laminated sheetsStandard: To AS 2924Type: High pressure laminateThickness (minimum):
· For horizontal surfaces fixed to a continuous background: 1.2mm· For vertical surfaces fixed to a continuous background: 0.8mm· For posted formes laminate fixed to a continuous background:.8mm· For vertical surfaces fixed intermittently (eg to studs): 3.0mm· For edge strops: 0.4mm
TIMBER VENEER
Important: the same Batch number is required for all joinery, loose furniture,workstations, timber panelling manufactured and installed
Designer to insert following information(Supplier; species; cut; Crown/quarter/quarter true, rotary, birdseye, /burls, quilted,figured, flame; Veneer to be book matched unless specified otherwise; Slipmatching/reverse slip matching/special; Finish - 2 Pak clear polyurethane (2 coatsminimum); Satin/semi gloss/full gloss.
MetalAL1: Anodised Aluminium - xxxxxxxPC1: Powdercoated Aluminium - xxxxxxxxMS: Mild SteelB.S.S: Brushed/Linished Stainless SteelP.S.S: Polished Stainless SteelC.P: Chrome Plated
Special SurfacesResin surface (satin, semi gloss, full gloss) xxxx
Painted Surfaces2 Pak polyurethane Paint Finish (Satin/semi gloss/full gloss)
CODESJOINERY INDEX
Benchtops / Built in Worktops/ TablesNominal finished thickness to all benchtops unless noted otherwise shall be35 mm.All benchtops are to be hand laminated / veneered as specified
Approved surface laminates:Laminex premium grade 1.1mm thick nominal laminate shall be used on allsurfaces unless noted otherwise.
Laminex Redback grade, 8mm thick laminate to be used for all post formedbench tops only.
Laminex Antistatic Redback laminate to be used on all I.T. tech andcomputer room bench /work tops only.
Veneers where specified shall be from supplier nominated and shall beconfirmed from same log batch unless agreed otherwise with Designer
Approved substrates:-32mm thick water resistant board to be used in all wet areas
(kitchen, tearooms, vanities etc)-33 mm thick HMR Particle Board-32 mm thick MR Craftwood
Underside of bench tops to be hand laminated/ veneered to extent ofprojection of bench top from face of internal carcases. Worktops to belaminated / veneered to full underside of top.
Tea bench: provide silicone seal to all junctions between joinery andwalls/floor. Colour to match laminate.
Doors, Carcases, panels and KickboardsExposed Slab ends: 33mm thick nom. (refer to drawings)Carcases: 18mm thick nom.Adjustable Shelves: 18mm thick nom. spanning to 900mm
25mm thick nom. spanning over 900mm - maximum of1000mm overall
Doors: 18mm thick nom. for all under bench and overheadCupboards
25mm thick nom. for all full height doors
Approved materials:Laminex prelaminated Structural MR / Laminex Vertiboard MR (carcases only)Laminex particleboard & Craftwood where veneer surface finish specified.18mm thick water resistant bosrd to be used for cupboards in all wet areas(kitchens, tearooms, vanities etc)
Scribbers: All built in joinery shall be scribbed to adjacent walls. Joiner to ensurewidth of scribbers is suitable for specified handles. Plumb and level all units andinstall adjustable feet where required.
Drawer Runners: Full extension bull bearing type - Hafele or similar approved (tobe nominated with tender).
Adjustable shelf supports: All shelves to be supported on approved nickel-platedspoon shaped supports and sleeves at 32mm increments to full height of carcasesstarting 100mm from top and bottom of carcase interiors.Hinges: Concealed type Salici or similar approved (to be nominated with tender).
Connectors: No exposed fixings allowable. All carcases to be fitted with press fitcolour matched trim caps to connectors.
Overhead units: Ensure fixings for overhead units are secured throughplasterboard into studwork. Plasterboard fixings only will not be accepted.
Hanging rails:25mm tubular rails (chrome finish) with support for long lengths
Sliding Tracks: xxxxxxxxxxx
Worktop/benchtops: Finished height of all worktops and benchtops to be amaximum +/- 10mm of specified height when existing floor conditions are takeninto account.
Grommets: Xxxxxxxxxxx
Edgestrips:Rigid 2mm thick ABS edge - colour to match benchtopPremium grade laminate edge - colour to match benchtop
Trims2mm nominal thick. Finished natural anodised trim to edge of tiles. Face of trim tobe flush with tile surfaceAll resin surfaces to have mitre joints unless specified otherwise
Electrical outlets: refer to joinery details for location of electrical outlets whereapplicable
Item
BinBlinds CarpetChairClockCoat HooksCutlery TrayDesk - ProprietaryDesk - Joinery (no screens)DishwasherDoorRangehoodExistingFabric or UpholsteryFilmFinished Ceiling level Finished Floor LevelFire Hose ReelFloor VinylFridge GlazingHandle -JoineryHandle - DoorHot water unitJoineryLaminateLight FittingMicrowavePedestal - MobileOperable Wall
Code
BEQCACFFFFFFDKJEQDEQEXUPFFCLFFLFHRFVEQGFFDEQJLFFEQMPEQ
Schedule
Loose FurnitureEquipmentFinishes
Loose FurnitureFittings & FixturesFittings & FixturesFittings & Fixtures
WorkstationJoinery
EquipmentDoor
EquipmentN/A
FinishesFinishes
N/AN/AN/A
FinishesEquipmentFinishes
Fittings & FixturesDoor Schedule
EquipmentJoineryFinishes
Fittings & FixturesEquipmentWorkstationEquipment
Item
OvenPaintPartitionPinboardPowdercoatProjectorProjector ScreenRangehoodReturnRugShowerSignageSink - Single Bowl/Double Bowl/basinSink MixerSkirtingSmartboardSplashback - GlassStoneStorageTable - Proprietary Table - JoineryTimber VeneerTowel RailTelevision Tiles - WallTiles - Floor includes MarbleWall Panelling - FeatureWhiteboard WorkstationWater Dispenser (Boiling, Chilled)
Code
EQPTPFFPCAVAVEQRTRGFFSGFFFFSKAVSBSSTTJTVFFAVWTFTJFFWSEQ
Schedule
EquipmentFinishes
N/AFittings & Fixtures
FinishesAudio VisualAudio VisualEquipmentWorkstation
FinishesFittings & Fixtures
SignageFittings & FixturesFittings & Fixtures
FinishesAudio Visual
FinishesFinishes
Loose FurnitureLoose Furniture
JoineryFinishes
Fittings & FixturesAudio Visual
FinishesFinishesJoinery
Fittings & FixturesWorkstationEquipment
GENERAL NOTES
JOINERY
Refer to finishes schedules.
JOINERY NOTES
Cabinetmaker is to fit appliances in liaison with Hydraulic and Electricalcontractors. Refer to equipment and Audio Visual schedule for details.
Joiner to produce shop drawings for all joinery for approval by designer prior tocommencement of works.
Joiner to check dimensions on site prior to commencement of works andrequest confirmation from Smith Madden representative if any queries. Do notscale from drawings.
Existing slab conditions to be checked by contractor and taken into account prior tomanufacture of all joinery items.
The associated drawings convey the designer’s intent regarding all visiblecomponents. Any structural or framing members are indicative only. Anyconcealed framing, fixing and under bench supports to be resolved bycontractor to ensure correct fixing, strength & structural stability. All fixingsto be concealed from normal viewing angles. All carcasses to be fitted withpress fit colour matched trim caps to fixing points.
Any variations to design intent depicted in associated drawings to be verified with SmithMadden group prior to manufacture of any work
All bench tops to be 33mm thick, finished in melamine with matching ABSedging (unless otherwise noted)
Joiner to make allowance to existing ducted skirting as indicated on drawing, and neatlycut joinery to suit as required.
All shelves to be supported on approved nickel plated spoon shaped supportsand sleeves at 32mm increments to full height of carcass starting at 100mmfrom top and bottom of carcass interiors.
All built - in joinery shall be scribed to adjacent walls. Plumb and level all units and installadjustable feet where required (unless otherwise noted)
Joints in bench tops and skirting are to line up with cupboard door lines where necessary.
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepancies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A08.01113 GOONDOON STREET, GLADSTONE03.09.12
JOINERY COVER SHEET TENDER
113 GOONDOON STREET, GLADSTONE
A08.01 JOINERY COVER SHEET AA08.02 JOINERY PLAN AA08.03 JOINERY DETAILS & ELEVATIONS AA08.04 JOINERY DETAILS & ELEVATIONS AA08.05 JOINERY DETAILS & ELEVATIONS AA08.06 JOINERY DETAILS & ELEVATIONS A
Rev. Date Chk DescriptionA 23.11.12 TENDER
UP
UP
UPDN
LARGE MEETINGG.03
OPEN OFFICEG.26
OFFICE 3G.05
KITC
HEN
ETTE
G.0
7
PWDG.10
FWCG.09
MWCG.08 QUIET RM
G.11
CLIENT MEETINGG.13
CLIENT MEETG.14
CUSTOMER WAITINGG.15
STOREG.17
COMPACTUSG.24
OFFICE 7G.23
OFFICE 5G.21
OFFICE 4G.20COMMS
G.25
1A08.06
4A08.03
1A08.04
3A08.06
1A08.03
Sim1
A08.04
1300 CLEAR
QUIET RMG.19
SMALL MEETINGG.04
OFFICE 1G.01
OFFICE 2G.02
PRINT 1G.06 BREAKOUT
G.12
STAFFG.16
OPEN OFFICEG.27
OPEN OFFICEG.28
BREAKOUTG.29
OPEN OFFICEG.30
OPEN OFFICEG.31
J03
J03
J01J05
J06
3200
2360
700
OFFICE 6G.22
1300 1695
J02
WC
WC
FEMALE TOILET1.02
SHOWER
MEETING/PING PONG ROOM
MALE TOILET1.01
UR
NIN
ALS
SHOWER
LUNCH ROOM1.03
1A08.05
NOT IN SCOPE
J04
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 100
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A08.02113 GOONDOON STREET, GLADSTONE03.09.12
JOINERY PLAN TENDER
1 : 100A08.021 GROUND FLOOR_FINISHES PLAN
1 : 100A08.022 FIRST FLOOR_JOINERY PLAN
0 5 10 m
Revision Date AmendmentsA 23.11.12 TENDER
A08.03
2
900
600
80 DIA CABLE DUCT
FFL-GL
0
L1
L1
10mm HIGH ROUTEDSLOTS TO FACE OFDOORS
900
900
4010
0
3A08.03
L1
FFL-GL
0
ADJ
ADJ
L1
A08.
03
5
TP1
700
400
SK1 TP1 SK1
COS
4480
COS
340
CO
S
329
FFL-GL
0
FCL-GL
2700
6A08.03
COS
4480
1100
OPEN
EQ EQ EQ EQ EQ
L5
L5 L5 L5
ADJ ADJ ADJ ADJ
SPLASHBACKL6
L5 L5 L5
L5
BIN
L2
L4
WALL MOUNTED ZIP BOILING WATER UNITTO BE POSITIONED OVER SINK DRAINER
ZIP CHILLEDWATER UNIT
100
L1
L5
BIN
ADJ ADJ ADJ
CUTLERY TRAY
ZIP
MIN
150
CO
S
773
L5
ADJ
578
TO SUIT FRIDGE
FR1
900
3560
0
NOTE - ALL HANDLESTO BE H1
1100
TP1 TP1
1109 1109 554 554 554
600
MIN
200
ADJ
FFL-GL
0
FCL-GL
2700
400
50
ADJ
TP1
L5
L4
L5
L6
L2
100
50
UNDERBENCH ZIPCHILLED WATER UNIT
ALLOW CUTOUT IN BASE OFCARCASS FOR VENTILATIONTO ZIP UNIT
35
20
900
600
1100
100
700
ADJ
30
NOTE:
JOINER TO CO-ORDINATE SIZE OF ALLWHITE GOODS WITH JOINERY CARCASS.
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
As indicated
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A08.03113 GOONDOON STREET, GLADSTONE03.09.12
JOINERY DETAILS & ELEVATIONS TENDER
1 : 20A08.031 J01 PLAN
1 : 20A08.032 J01 ELEVATION 1 : 20A08.03
3 J01 SECTION
1 : 20A08.034 J02 KITCHENETTE PLAN
1 : 20A08.035 J02 KITCHENETTE ELEVATION
1 : 20A08.036 J02 KITCHENETTE SECTION
L4
NOTE - JOINER TO CO-ORDINATE SIZE OF ALLWHITEGOODS, SINKS & TAPWARE WITH JOINERY CARCASS
Revision Date AmendmentsA 23.11.12 TENDER
A08.04
2
3A08.04
600
350
PRINTER
FFL-GL
0
FCL-GL
2700
900
3510
0
EQEQEQ
L4
L2
L5
600
1100
100
L1
ADJ
EQ DOUBLE CUPBOARDS NUMBER TO SUIT LENGTH MAX 900mm WIDE EACH
REFER TO JOINERY PLAN A08 FOR LENGTH
ADJ ADJ
ADJ ADJ ADJ
ADJ ADJ ADJ
ADJ ADJ ADJ
PIN1
ALUMINIUM ANGLESURROUND TOEXPOSED EDGES
1300 CLEAR
REFER TO JOINERY PLAN A08 FOR LENGTH
PRINTER
FFL-GL
0
FCL-GL
2700100
1100
600
900
30
600
20
100
35
50
50
ADJ
ADJ
ADJ
ADJ
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 20
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A08.04113 GOONDOON STREET, GLADSTONE03.09.12
JOINERY DETAILS & ELEVATIONS TENDER
1 : 20A08.041 J03 PRINT STATION PLAN
1 : 20A08.042 J03 PRINT ELEVATION
1 : 20A08.043 J03 PRINT SECTION
Revision Date AmendmentsA 23.11.12 TENDER
6680 COS
FRIDGE FRIDGEMW MWL4
4A08.05
SK1
TP1
5260
70060
5
DW
400
SK1
TP1
FFL-L1
3700
2 X MICROWAVESJOINER TO CO-ORDINATESIZE REQUIRED
OPEN
FR2FR2
SPLASHBACK
ADJ
ADJ
ADJADJ ADJ ADJ
L5L5
L5 L5
L5 L5
L5
L5
L5
L5L5
850
TO S
UIT
FR
IDG
ES
1750
1100
1500
600
100
CUPBOARD
600
ADJ
ADJ
ADJ
ADJ
ADJ
L2
L4
L1
NOTE - ALL HANDLESTO BE H1
L6
WALL MOUNTED ZIP BOILING WATER UNITTO BE POSITIONED OVER SINK DRAINER
RUBBISH
3A08.05
L2L2
ZIP L5
ZIP CHILLEDWATER UNIT
TO SUIT MICROWAVE OVENS
1200
OPENING TO SUIT FRIDGES
DRAWERS
600
DRAWERS
600
L5
RECYCLE
NOTE - JOINER TO CO-ORDINATE SIZE OF ALLWHITEGOODS WITH JOINERY CARCASS
CUTLERYINSERTS TOTOP DRAWERS
ADJ
ADJ
ADJ
ADJ
4A08.05
100
SIDEPANEL
MIN
150
CO
S
773
578
FCL-L1
6400
MW MW
115311541153
MIN
200
DISHWASHER
600
BIN DRAWER
600
1420
L5
ADJ
3 X CUPBOARDS
1660
BIN DRAWER
600
TP1 TP1
773
1828
100
400
50
30
100
50
TP1
UNDERBENCH ZIPCHILLED WATER UNIT
ALLOW CUTOUT IN BASE OFCARCASS FOR VENTILATIONTO ZIP UNIT
ADJ
700
20
35
L5
FFL-L1
3700
ADJ
100
30
L5
L5
L5
L2
50
SIDE PANEL TOMICROWAVECOMPARTMENT
100
400
50FCL-L1
6400
900
35
700
20
50
605
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 20
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A08.05113 GOONDOON STREET, GLADSTONE03.09.12
JOINERY DETAILS & ELEVATIONS TENDER
1 : 20A08.051 J04 LUNCH PLAN
1 : 20A08.052 J04 LUNCH ELEVATION
1 : 20A08.053 J04 SECTION B
1 : 20A08.054 J04 SECTION A
Revision Date AmendmentsA 23.11.12 TENDER
A08.
06
2
L4
600
COS
3200
CLEAR
700
RECYCLEBIN
FFL-GL
0
FCL-GL
2700
900
6 X EQ CUPBOARD DOORS
3200
4010
0
6A08.06
CLEAR
700
600
1100
100
CO
S
L1L1L1
PIN1
L5 L5 L5
L4
L2
ADJ
ADJ
ADJ
ADJ
ADJ
ADJ
6 X EQ CUPBOARD DOORS
ADJ
ADJ
ADJ
ADJ
ADJ
ADJ
L1
ALUMINIUM ANGLE TOEXPOSED EDGES
RECYCLEBIN
GALVANISED DROP IN PLANTERCONTAINER ALLOW FORDRAINAGE TO CONTAINERS -PLANTER INTERNAL TO BEWATERPROOFED
3mm GAP BETWEENALL TIMBERS
MITRE ALL CORNER JOINS
2800
450
101
101
A08.06
4
A08.06 5
120
TIM2
TIM2
4 X UPHOLSTEREDCUSHIONS
120
101 101
ø 400
FFL-GL
0
450
2800
3mm GAP BETWEEN BOARDS
EQ
TIM2EQEQ
FFL-GL
0
450
3mm GAP BETWEEN BOARDS
EQ
TIM2EQEQ
ADJ
ADJ
ADJ
ADJ
20
50
600
30
400
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 20
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A08.06113 GOONDOON STREET, GLADSTONE03.09.12
JOINERY DETAILS & ELEVATIONS TENDER
1 : 20A08.061 J05 UTILITIES PLAN
1 : 20A08.062 J05 ELEV
1 : 20A08.063 J06 PLANTER PLAN
1 : 20A08.064 J06 ELEV A
1 : 20A08.065 J06 ELEV B
1 : 20A08.066 J05 SECTION
Revision Date AmendmentsA 23.11.12 TENDER
FFL-GL
0
FCL-GL
2700
2A09
EQ EQ
COS
10279
100
1200
LB LB LB
SK1
SINGLE SIDE FLEX FACELIGHTBOXWITH CUSTOM PRINTGRAPHIC
GF3 GF3 GF3
P4
EQ
FFL-GL
0
FCL-GL
2700
1500
1200
SINGLE SIDE FLEX FACE LIGHT BOXWITH CUSTOM PRINT GRAPHIC
STUD WALL BUILT OUT TO SUITTHICKNESS OF LIGHT BOX
200
FFL-GL
0
FCL-GL
2700
GF1
1500
300
1200 GF1 GF1 GF1
FFL-GL
0
FCL-GL
2700
EQEQ
EQ EQ
GF1
GF1
GLADSTONE REGIONAL COUNCILLOGO IN COLOUR
1200
1200
FFL-L1
3700
100
SK1
FCL-L1
6400
PT1
FFL-L1
3700
12mm ACRYLIC SCREEN WITHMOTIF CUTOUTS
1000
EXISTING POSTPT04 FINISH
NEW POST. SIZE & SHAPE TO MATCHEXISTING WITH CONCEALED FIXINGS.PT04 FINISH
ALUMINIUM CHANNELTO SUIT WITH PT04 FINISH.
SCR1
7A09
FCL-L1
6400
1000
2700
CO
S
ACRYLIC SHEET 12mm THICKWITH MOTIF CUTOUTS.ALLOW TO CUT DOWN TO SUITCEILING HEIGHT.
351`
351`
96` 96`
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
As indicated
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A09113 GOONDOON STREET, GLADSTONE03.09.12
ELEVATIONS TENDER
1 : 50A091 ELEVATION - LIGHTBOX WALL
1 : 50A092 SECTION - LIGHTBOX SECTION
1 : 50A093 ELEVATION - TYPICAL FILM DETAIL TO ALL G1 GLASS PARTITIONS
1 : 50A094 ELEVATION - CUSTOMER WAITING
1 : 50A095 ELEVATION A - FIRST FLOOR LUNCH ROOM
1 : 50A096 ELEVATION B - FIRST FLOOR LUNCH ROOM
1 : 20A097 ACRYLIC SCREEN SCR1
Revision Date AmendmentsA 23.11.12 TENDER
A09.01
2
WC1
WC1
WB2
TP2
WB2
TP2
LAMINATEBENCH
LAMINATEBENCH
TP2
GR2
WC2
GR2
GR1
GR1
GR1
GR1
FT1
FT1
FT1
FT1
A09.01
5
4
3
6
425
MIN
310
MIN
110
310
NO
M
WB3
MAX
400
120
R35
LAMINATESHELF
300
250
R35
AMBULANT TOILETS TO AS1428.1-2009
ACCESSIBLE TOILET TO AS1428.1-2009
M2
M2
L1
L1
L1
M2
- 100mm X 200mmCOVING TILE - GROUTLINES BETWEEN FLOORAND COVE TILE TO ALIGN
FT2
FT1
PD1
PD1
PD1
FFL-GL
0
FCL-GL
2700
WC1
WB2
TP2
BT
SPLASHBACK
L1
400
GR1
TO 8
10
800
TO 250
200
100
100
M2
MIR
RO
R
1000
WT1
10mm BEVEL EDGE TOMIRROR EDGES
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
PAP
ER T
OW
EL D
ISPE
NS
ER
1400
PAPER TOWEL DISPENSER SUPPLIED BYCLIENT AND INSTALLED BY CONTRACTOR
PD1
FFL-GL
0
FCL-GL
2700
GR
AB R
AIL
800
100
WC2
GR2
TRH
700
MAX
300 MAX
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
FFL-GL
0
FCL-GL
2700
WC2
100
GR2
50 MAX
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
FFL-GL
0
FCL-GL
2700
TP2
WB310
0
PAPER TOWEL DISPENSER SUPPLIED BY CLIENTAND INSTALLED BY CONTRACTOR - OUTLET TOPAPER TOWEL DISPENSER TO BE NO LESS THAN900mm OR NO MORE THAN 1100mm ABOVE FFL
- 100mm X 200mm COVING TILE -GROUT LINES BETWEEN FLOOR ANDCOVE TILE TO ALIGN
FT2
500 MIN
700
REF
ER T
O N
OTE
ABO
VE
935
PD1
800
MIN
830
BAS
IN
MIN
800
830
SH
ELF
1000
M2
320
WB3
D08
WT1
10mm BEVEL EDGETO MIRROR EDGES
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
PD1
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 20
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A09.01113 GOONDOON STREET, GLADSTONE03.09.12
TOILET DETAILS TENDER
1 : 20A09.011 PLAN - GROUND FLOOR TOILETS
1 : 20A09.012 ELEVATION - FIRST FLOOT TYPICAL AMBULANT TOILET
1 : 20A09.013 ELEVATION 1- GROUND FLOOR ACCESSIBLE TOILET
1 : 20A09.014 ELEVATION 2 - GROUND FLOOR ACCESSIBLE TOILET
1 : 20A09.015 ELEVATION 3 - GROUND FLOOR ACCESSIBLE TOILET
1 : 20A09.016 ELEVATION 4 - GROUND FLOOR ACCESSIBLE TOILET
NOTE
DISABLED TOILETS TO COMPLY WITH AS 1428.1 - 2009
Revision Date AmendmentsA 23.11.12 TENDER
UR1
UR1
WC1 WC1
WC1 WC1
WC1WC1
A09.03
2
A09.02
2
A09.03 1
A09.033
1000
1105
WB1 WB1 WB1
WB1WB1WB1
TP2 TP2 TP2
TP2TP2 TP2
PLINTH WALL BOTH SIDES1000 AFFL TO CREATE SHELF
NOTE - ALL TOILET ROLL HOLDERS TO BEINSTALLED 700mm FROM FFL TO BASE OFTOILET ROLL HOLDER
TRH TRH
TRH TRH
TRHTRH
HK
HK
BS
BS
SCRN
TR
SCRN
TR
TR6
SR
SR
TP3
TP3
SHLF
SHLF
FT1
FT1
FT1
FT1
FT1
FT1FT1
M1
M1
M1
M1 M1
M1
5
WASTE
WASTE
TILE SHOWER ENCLOSURE WALLS WT1 WITH SKIRTING 100mm HIGH
TILE SHOWER ENCLOSURE WALLS WT1 WITH SKIRTING 100mm HIGH
L3
L3
WT1
WT1
WT1
WT1
WT1
WT1
72
FT1FT1FT1
FT1
FT1
FT1
- 100mm X 200mmCOVING TILE - GROUTLINES BETWEEN FLOORAND COVE TILE TO ALIGN
FT2
PD1
PD1
PAPER TOWEL DISPENSER SUPPLIED BYCLIENT AND INSTALLED BY CONTRACTOR1400 AFFL TO BOTTOM OF DISPENSER
PAPER TOWEL DISPENSER SUPPLIED BYCLIENT AND INSTALLED BY CONTRACTOR1400 AFFL TO BOTTOM OF DISPENSER
150
100
FFL-L1
3700
3380 COS
M1 M1 M1
TP TP TP
1016
1000
900
MIRROR
EQ
MIRROR
EQ
MIRROR
EQ
1127 1127
- 100mm X 100mm
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGN
3A09.02
FT2
WT1
100
FCL-L1
6400
BUTT
JO
IN
BUTT
JO
IN
10mm BEVEL EDGE TO MIRROR EDGES
PAP
ER T
OW
EL D
ISPE
NS
ER
1400
PD1
PAPER TOWEL DISPENSER SUPPLIED BYCLIENT AND INSTALLED BY CONTRACTOR
100
FFL-L1
3700
WB1
TP2
BT
M1 MIRROR
L3
FT2FT1
POLISHL3 EDGE
150
1000
PLINTH WALL
WT1 100
900
PAP
E R T
OW
E L D
ISP
ENSE
R
1400
PD1
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
As indicated
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A09.02113 GOONDOON STREET, GLADSTONE03.09.12
TOILET DETAILS TENDER
1 : 20A09.021 FIRST FLOOR FRONT TOILETS PROPOSED DETAILS PLAN
1 : 20A09.022 ELEVATION 1 - FIRST FLOOR WASH BASINS TYPICAL
1 : 10A09.023 SECTION - FIRST FLOOR TOILETS
Revision Date AmendmentsA 23.11.12 TENDER
FFL-L1
3700
UR1 UR1
100
1400
WT2
STAINLESS STEEL ANGLETO EDGE OF WALL TILES
FCL-L1
6400
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
FFL-L1
3700835
TR
TR
TOW
EL R
AIL
900
TOW
EL
RA
IL
900
EQ EQ
FT2
TILEDHOB
100
SHLF
SR
TP3
1100
HK
FCL-L1
6400
2000
WT1
TOWEL RAILCENTRE
1135
CLO
T HES
HO
OKS
1600
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
SCRNSHOWERSCREEN
FFL-L1
3700
TR
TR
HK
TOW
EL
RA
ILS
900
CLO
THES
HO
OKS
1600
SR
TP3SHLF
WT1
FT2
100
TILEDHOB
FCL-L1
6400
800
TOWEL RAIL CENTRE
1100
TOW
LEL
RA
ILS
900
2000
1100 BS
P3
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
SCRNSHOWERSCREEN
WC1
NOTE - ALL TOILET ROLL HOLDERSTO BE INSTALLED 700mm FROM FFLTO BASE OF TOILET ROLL HOLDER
TRH TRH
WC1
FT1
FT1 FT1
FT1FT1
WB1
TP2
WB1
TP2
PLI
NTH
WAL
L FO
R W
ASH
BA
SIN
1127
3A09.02
Sim
A09.02 2M1 M1
L3 L3
- 100mm X 200mm COVINGTILE - GROUT LINES BETWEENFLOOR AND COVE TILE TO ALIGN
FT2
PD1 PD1
150
150
PAPER TOWEL DISPENSERSSUPPLIED BY CLIENT ANDINSTALLED BY CONTRACTOR 1400AFFL TO BOTTOM OF DISPENSER
FFL-L1
3700
FCL-L1
6400
BS
TR
TRHK
CLO
T HES
HO
OKS
1600
TOW
EL R
AIL
900
TOW
EL
RA
IL
900
100
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
TR
TR
BS
HK
FT2
WT1
2000
FT2
100
- 100mm X 200mm COVING TILE - GROUT LINESBETWEEN FLOOR AND COVE TILE TO ALIGNFT2
SCRNSHOWERSCREEN
Contractors must verify all dimensionson site, and notify Smith MaddenGroup of any discrepencies prior tocarrying out any works. Writtendimensions take precedence overscaled dimensions.
GLADSTONE REGIONAL COUNCIL RETAINS COPYRIGHT ON THIS DRAWING.
Stage / Drawing NoMelbourne +61 3 9663 6055 Job No
Revision
Scale @ A1
Date
Designer Drawn
Project Manager
www.smithmadden.com.au
Client
Address
Title
Approx Area
Sydney +61 2 8243 3700
Brisbane +61 7 3002 6999
Perth +61 8 9325 5522
The Area Indicated is indicative and cannot be used as an identification of the Actual Lease Area.
1 : 20
AGLADSTONE REGIONAL COUNCIL
JCTN
RR
400597
A09.03113 GOONDOON STREET, GLADSTONE03.09.12
TOILET DETAILS TENDER
1 : 20A09.031 ELEVATION 3 - FIRST FLOOR URINALS
1 : 20A09.033 ELEVATION 4 - FIRST FLOOR MALE SHOWER
1 : 20A09.032 ELEVATION 2 - FIRST FLOOR FEMALE SHOWER
1 : 20A09.034 FIRST FLOOR REAR TOILETS PROPOSED DETAIL PLAN
1 : 20A09.035 ELEVATION 1 - FIRST FLOOR FEMALE SHOWER
1 : 20A09.036 ELEVATION 5 - FIRST FLOOR MALE SHOWER
Revision Date AmendmentsA 23.11.12 TENDER
1 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Finishes Furniture & Joinery Schedule
project : Gladstone Regional Council project # : 400597 project address : 113 Goondoon Street, Gladstone date : November 2012 project team:
name position phone
Hugh Harris Director 3002 6914 [email protected]
Victoria Robson Design Assistant 3002 6990 [email protected]
Rob Rose Project Manager 3002 6912 [email protected]
summary of revisions/amendments
addendum #
description of revisions/amendments
date
01 TENDER 23.11.2012
2 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Finishes schedule code finish location supplier specification flooring CPT1 Carpet General
Please refer to drawings for specific locations.
Interface Flor Range: Velocity Colour: Degree
CPT2 Carpet General
Please refer to drawings for specific locations.
Interface Flor Range: Velocity Colour: Ratio
CPT3 Carpet Feature
Please refer to drawings for specific locations.
Interface Flor Range: Monochrome Colour: Yew
CPT4 Carpet Feature
Please refer to drawings for specific locations.
Interface Flor Range: Monochrome Colour: Asparagus
CPT5 Carpet Feature
Please refer to drawings for specific locations.
Interface Flor Range: Monochrome Colour: Artichoke
3 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Finishes schedule code finish location supplier specification CPT6 Carpet Feature
Please refer to drawings for specific locations.
Interface Flor Range: Monochrome Colour: Legacy
CPT7 Carpet Feature Please refer to drawings for specific locations.
Interface Flor Range: Monochrome Colour: Medici Blue
CPT8 Carpet Feature Please refer to drawings for specific locations.
Interface Flor Range: Monochrome Cpt8: Colour: Juniper
CPT9 Carpet Feature Please refer to drawings for specific locations.
Interface Flor Range: Monochrome Colour: Morning Glory
CPT10 Carpet Feature Please refer to drawings for specific locations.
Interface Flor Range: Monochrome Colour: Spun Gold
4 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Finishes schedule code finish location supplier specification V1 Vinyl
Staff Kitchen Kitchenette Comms Room
Armstrong Accolada Safe Plus Black Opal 2mm thick Installation as per manufacturers guidelines
FT1 Floor Tile Amenities Granito Range: Salsa Colour: Oasis Ivory R11 Matt finish Dimensions: 200 x 200
FT2 Cove Tile Amenities Granito Range: Cove
Colour: Ivory Matt finish Dimensions: 200mm x 100mm x 28mm
NOTE: ALUMINIUM ANGLE TO ALL FLOORING JUNCTIONS walls PT01 Paint General walls
throughout
Bristol Bassinet P001-L3 Low VOC Low sheen finish
PT02 Paint Reception Feature Wall Door and Frames
Bristol Bistro Green P160-C7 Wall Finish: Low sheen Door and Frame Finish: Semi gloss
PT04 Paint Existing & new column in Kitchen
Bristol Bassinet P001-L3 Finish: High Gloss
5 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Finishes schedule code finish location supplier specification Walls PT05 Paint Amenities Bristol Bassinet P001-L3
Low VOC Semi gloss finish
FB1 Fabric Operable Wall
Woven Image Range: Echo Panel Mura Otto Colour: 362 Lettuce on Cream
L3 Laminate Amenities Laminex Compact Laminate 10mm thick Alaskan 334
SCR1 Feature acrylic screen
Lunch Room Baresque Lightblocks Taglio Breeze 10mm Clear 3000mm x 1000mm
WT1 Wall Tile Amenities Walls National Tiles Gloss White 100 x 100 Tiles
WT2 Wall Tile Amenities Walls National Tiles Gloss Grey 100 x 100 Tiles
WTG1 Wall Tile Grout Amenities Ardex Range: Ardex FG8 Colour: 200 White Thickness 3mm
WTG2 Urinal Wall Tile Grout
Male toilets Metz Tiles Metz 19 Epoxy Grout Colour: Dark Grey to match wall tile
frames ALU Aluminium ceilings PT04 Paint Level 1 Ceiling
skirting SK1 aluminium General 100mm clear anodised Alum.
Grey rubber insert Glazing film GF1 Glazing Film Refer elevations Signage Contractor 3M Dusted Crystal 7725-314
Acid Etched Look
GF2 Glazing Film Refer elevations Signage Contractor Custom Print Vinyl Graphic
GF3 Glazing Film Refer elevations Signage Contractor Custom Print Vinyl Graphic
6 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Furniture schedule code supplier specification image WSA WSB
Specfurn Straight Genny workstations 1800 x 750 and 2100 x 750 and 4 x Hot desks 1500 x 750 with 30mm x 480h Screens to be 1250mm high upholstered in Hex Screen fabric, along the spines, attached to the worktops and slide on Melamine dividing screens between workstations and at the open corridor ends. Each workstation to have cable trays under the desk fitted with power rail for 4 GPO and plates for 2 data . One x yellow umbilical per cluster of workstations. 25mm 'White' tops and 1 x screen mounted shelf. Desk Finish: Laminex Colour: White 200 Finish: Natural Finish Leg Finish: Dulux powder coat Colour: White Satin 1139S Duralloy Pinboard Finish: Woven Image Range: Echo Screen Hex Colour: 101 Grey
With aluminium angle to all exposed edges
IMAGE IS INDICATIVE ONLY
7 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Furniture schedule code supplier specification image WSC Office desk
L shape Genny desks/returns 2100 x 1800 x 750 with mobile caddy and modesty Wall mounted pinboard 600mm high in Hex Screen fabric. Desk Finish: Laminex Colour: Sublime Teak 288 Finish: Natural Finish Leg Finish: Dulx powder coat Colour: White Satin 1139S Duralloy Pinboard Finish: Woven Image Range: Echo Screen Hex Colour: 468 Cream
With aluminium angle to all exposed edges
WSD Laminate desk with matching slab ends 720mmH desks refer drawings for depth and length measurements Finish: Laminex Colour: White 200 Finish: Natural Finish
NO IMAGE
8 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Furniture schedule code supplier specification image C1 Visitor Chair
Specfurn Zebra fully upholstered chair Upholstery: Woven Image Range: Global Colour: 384 Apple
C2 Meeting and Task Chair
Specfurn Rexa chair 2 lever, Medium back, fully upholstered, CAT 2 fabric, with arms, AFRDI level 6 and GECA certified
C3 Breakout bar stool
Chairbiz Lilly TPSG 720mmH Frame finish: chromed steel Seat colour: White
C4 Breakout Single Seater Lounge
Specfurn PLYLO client chair Upholstery: Woven Image Range: Global Colour: 384 Apple
9 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Furniture schedule code supplier specification image C5 Breakout 2 Seater Lounge
Zenith Troy Lounge Size: 1845 long Upholstery: Woven Image Range: Global Colour: 444 Quarry
C6 Breakout Stool
Stylecraft Harlie Stool 450mmH x 450mmW x 520mmD Colour: Blue
C7 Dining Chair
Café Culture Moema Legs finish: White powder coated steel Seat finish: White 590mm x 540mm x 470mmH
T1 Meeting Table 1
Specfurn I.AM Rectangular Table 1800mmL x 1100mmW x 720mmH Finish: Laminex Colour: Sublime Teak 288 Finish: Natural Finish With matching ABS edge
10 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Furniture schedule code supplier specification image T2 Breakout Bar Table
Eurofurn Plantation 1100mW x 2400mmL x 1050mmH Finish: Spotted gum Solid timber frame and stainless steel foot rail
T3 Breakout Coffee Table
Café Culture Link Table Powder coated steel Colour: White 640mm DIA x 320mmH
T4 Breakout Dining Table
Café Culture Doll table 800mmW x 800mmD x 750mmH Top: White Base: White
T5 Dining Table
Baresque LA Base Powder Coated, 695mmH to suit a Lightblocks Ply Top 900mm DIA Base Finish: Dulx powder coat Colour: White Satin 1139S Duralloy Top Finish: Lightblocks Ply Top Colour: Vivid White
T6 Meeting Table 2
Specfurn I.AM TURN Rectangular Table 1800mmL x 1100mmW x 720mmH Finish: Laminex Colour: Sublime Teak 288 Finish: Natural Finish With matching ABS edge
11 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Furniture schedule code supplier specification image ST1 Tambour unit with planter
Planex S Series Tambour Door cabinets and Flox planter boxes Unit:1000mm High x 900mm Wide x 500mm Deep Flox: 225mm High for 3 plants 200mm pots Unit: Fitted with 2 shelves, 3 square toast racks Flox: Fitted with insert tray and drip tray and Colour: Satin White rubber feet
ST2 Full Height Storage Unit
Specfurn Open Metal Storage Unit 5 No. Adjustable Shelves Finish: Standard White Powdercoat Dimensions: 1980H x 900W x 450D
ST3 Mobile caddy storage unit
Specfurn Caddy with 3 drawers and open shelving area Finish: Dulux Powder coat Colour: Lemon Yellow Gloss 984-32120 Allow Caddy for each workstation and office
12 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Furniture schedule code supplier specification image ST4 Compactus
Dexion Mekdrive Compactus Size: 9160L x 2075D No of Bays: 36 No of Bay wide: 18 No of Bays deep: 2 Bay arrangement: 2 single sides and 8 double sided Minimum Aisle width: 800mm Tracks & Runners: Low profile anodised incorporating anti-tilt mechanism Ergonomic operating hand wheel operation of the belt drive Shelving Bays: 2175H x 900W x 400D, 2 bays per block Storage Levels: no of storage levels 5 Finish: Stone White colourbond
13 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
joinery schedule code finish location supplier Specification J01 Resident PC Cupboard L1 Laminate Joinery top and
doors Laminex Colour: White 200
Finish: Natural Finish
L2 Laminate Kick Laminex Laminex Innovation
Colour: Brushed Stainless Steel 957 Finish: Metallic Finish
H3 Handle Doors & Drawers Barben BAC 166-A
14 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
joinery schedule code finish location supplier Specification J02 Kitchenette L5 Laminate Under bench
cupboards and overheads
Laminex Colour: Sublime Teak 288 Finish: Natural Finish
L6 Laminate Splashback Laminex Laminex Innovations
Pure Clone 117 Finish: Gloss Finish
L4 Laminate Bench top Laminex Colour: Pure Calcite 221
Finish: Natural Finish With squareform edge
L2 Laminate Kick Laminex Laminex Innovations Colour: Brushed Stainless Steel 957 Finish: Metallic Finish
H3 Handle Doors & Drawers Barben BAC 166-A
15 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
joinery schedule code finish location supplier Specification J03 Typical Print Utility L1 Laminate Overheads Laminex Colour: White 200
Finish: Natural Finish
L4 Laminate Bench top Laminex
Squareform Colour: Pure Calcite 221 Finish: Natural Finish With squareform edge
L5 Laminate Under bench cupboards
Laminex Colour: Sublime Teak 288 Finish: Natural Finish
L2 Laminate Kick Laminex Laminex Innovation
Colour: Brushed Stainless Steel 957 Finish: Metallic Finish
H3 Handle Doors & Drawers Barben BAC 166-A
16 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
joinery schedule code finish location supplier Specification J04 Staff Kitchen L5 Laminate Under bench
cupboards and overheads
Laminex Colour: Sublime Teak 288 Finish: Natural Finish
L4 Laminate Bench top Laminex Colour: Pure Calcite 221
Finish: Natural Finish With squareform edge
L2 Laminate Kick Laminex Laminex Innovation
Colour: Brushed Stainless Steel 957 Finish: Metallic Finish
H3 Handle Doors & Drawers Barben BAC 166-A
J05 Timber Bench with Seat Cushions TB Timber bench Boral Tallow wood
Water based sealant Satin Finish NOTE: supplier to provide suitable lengths to suit as drawn
FB2 Fabric Seat cushions Woven Image
Range: Hex Colour: 273 Navy/cobalt
17 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
Joinery schedule code finish location supplier Specification Joinery: Cabinetmaker is to fit appliances in liaison with Hydraulic and Electrical contractors. Refer to equipment and Audio Visual schedule for details. Joiner to produce shop drawings for all joinery for approval by designer prior to commencement of works. Joiner to check dimensions on site prior to commencement of works and request confirmation from Smith Madden representative if any queries. Do not scale from drawings. Existing slab conditions to be checked by contractor and taken into account prior to manufacture of all joinery items. The associated drawings convey the designer’s intent regarding all visible components. Any structural or framing members are indicative only. Any concealed framing, fixing and under bench supports to be resolved by contractor to ensure correct fixing, strength & structural stability. All fixings to be concealed from normal viewing angles. All carcasses to be fitted with press fit colour matched trim caps to fixing points. Any variations to design intent depicted in associated drawings to be verified with Smith Madden Group prior to manufacture of any work All bench tops to be 33mm thick, finished in melamine with matching ABS edging (unless otherwise noted) Joiner to make allowance to existing ducted skirting as indicated on drawing, and neatly cut joinery to suit as required. All shelves to be supported on approved nickel plated spoon shaped supports and sleeves at 32mm increments to full height of carcass starting at 100mm from top and bottom of carcass interiors. All built – in joinery shall be scribed to adjacent walls. Plumb and level all units and install adjustable feet where required (unless otherwise noted) Joints in bench tops and skirting are to line up with cupboard door lines where necessary Benchtops / Built in Worktops/ Tables Nominal finished thickness to all benchtops unless noted otherwise shall be 35 mm. All benchtops are to be hand laminated / veneered as specified Approved surface laminates: Laminex premium grade 1.1mm thick nominal laminate shall be used on all surfaces unless noted otherwise. Laminex Redback grade, 8mm thick laminate to be used for all post formed bench tops only. Laminex Antistatic Redback laminate to be used on all I.T. tech and computer room bench /work tops only. Veneers where specified shall be from supplier nominated and shall be confirmed from same log batch unless agreed otherwise with Designer Approved substrates: 32mm thick water resistant board to be used in all wet areas (kitchen, tearooms, vanities etc) 33 mm thick HMR Particle Board 32 mm thick MR Craftwood Underside of bench tops to be hand laminated/ veneered to extent of projection of bench top from face of internal carcases. Worktops to be laminated / veneered to full underside of top. Tea bench: provide silicone seal to all junctions between joinery and walls/floor. Colour to match laminate. Doors, Carcases, panels and Kickboards Exposed Slab ends: 33mm thick nom. (refer to drawings) Carcases: 18mm thick nom. Adjustable Shelves: 25mm thick nom. spanning to 900mm Doors: 18mm thick nom. for all under bench and overhead Cupboards 25mm thick nom. for all full height doors
Approved materials: Laminex prelaminated Structural MR / Laminex Vertiboard MR (carcases only) Laminex particleboard & Craftwood where veneer surface finish specified. 18mm thick water resistant board to be used for cupboards in all wet areas (kitchens, tearooms, vanities etc) Scribbers: All built in joinery shall be scribbed to adjacent walls. Joiner to ensure width of scribbers is suitable for specified handles. Plumb and level all units and install adjustable feet where required. Drawer Runners: Full extension bull bearing type – Hafele or similar approved (to be nominated with tender). Adjustable shelf supports: All shelves to be supported on approved nickel-plated spoon shaped supports and sleeves at 32mm increments to full height of carcases starting 100mm from top and bottom of carcase interiors. Hinges: Concealed type Salici or similar approved (to be nominated with tender). Connectors: No exposed fixings allowable. All carcases to be fitted with press fit colour matched trim caps to connectors. Overhead units: Ensure fixings for overhead units are secured through plasterboard into studwork. Plasterboard fixings only will not be accepted. Hanging rails:25mm tubular rails (chrome finish) with support for long lengths Sliding Tracks: xxxxxxxxxxx Worktop/benchtops: Finished height of all worktops and benchtops to be a maximum +/- 10mm of specified height when existing floor conditions are taken into account. Grommets: Xxxxxxxxxxx Edgestrips: Rigid 2mm thick ABS edge - colour to match benchtop Premium grade laminate edge – colour to match benchtop Trims 2mm nominal thick. Finished natural anodised trim to edge of tiles. Face of trim to be flush with tile surface All resin surfaces to have mitre joints unless specified otherwise Electrical outlets: refer to joinery details for location of electrical outlets where applicable
18 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
fittings fixtures and equipment schedule item supplier specification image Lightbox – Rear Wall Signarama Lightbox
Single Side Flex Face lightbox Top hinged with custom print graphic to face Dimensions: refer drawings
J02 Kitchenette FR1 Bar Fridge
Fisher and Paykel
Bar Fridge 115L P120RX Finish: EZKleen Stainless Steel Dimensions: H 819 x W 525 x D 570
TP1 Mixer Tap
Clark Irwell Pin Lever Sink Mixer Gooseneck Outlet
Chrome
SK1 Sink
Clark
Quatro Single End Bowl 20.2L per bowl 800L x 500W x 197D
RB Rubbish Bins
Joiner
Pull out Drawer
Size: Refer joinery drawings
Joiner to construct drawer base and provide 1 full size bin
Finish: Black Melamine
Qty = 2
19 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
fittings fixtures and equipment schedule item supplier specification image J04 Staff Kitchen FR2 Upright Fridge with Top Freezer
Fisher and Paykel
ActiveSmart™ Fridge- Top Freezer 447L E440TRX3 Finish: EZKleen Stainless Steel Dimensions: H 1695 x W 680 x D 715
TP1 Mixer Tap
Clark Irwell Pin Lever Sink Mixer Gooseneck Outlet
Chrome
SK1 Sink
Clark
Quatro Single End Bowl 20.2L per bowl 800L x 500W x 197D
MW Microwave
Panasonic
NN-ST671S Microwave Oven, 32 L capacity Finish: S/steel
DW Dishwasher
Fisher and Paykel
Dishwasher DW60CEX1 Finish: Brushed Stainless Steel Dimensions: H 850 - 870 x W 595 x D 600
RB Rubbish Bins
Joiner Pull out Drawer
Size: Refer joinery drawings
Joiner to construct drawer base and provide 1 full size bin
Finish: Black Melamine
Qty = 2
20 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
fittings fixtures and equipment schedule item supplier specification image Amenities WB1 Wall Basin
Reece Ideal Standard Concept Wall Basin
WB2 Wall Basin
Reece White Stone Hox Mini Wall Basin
TP2 Mixer Tap 2
Reece Mizu Basin Mixer
BT Bottle Trap
Reece Mizu Bottle Trap
TP3 Shower mixer Tap
Reece Mizu Shower Mixer
SR Shower Rail
Reece Posh Bristol Shower Rail
SCRN Shower Screen
Stegbar Softline Series Framed Glass screen with hinged door Size: to suit opening
21 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
fittings fixtures and equipment schedule item supplier specification image WC1 Toilet
Harvey Norman Commercial
RAK Bathware B Cool Close Coupled Suite S Trap Concealed Floor Fixings White ABS Toilet Seat & lid with Stainless Steel Hinges 4 Star Wels Rated Dual Flush Cistern
GR1 Ambulant Grab Rail
Grab Rail Clean Seal Model No. GRCS05 Left hand model and right hand model
UR1
Watersave Australia
Brand: Uriden Model: KH-6 Finish: Ceramic
22 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
fittings fixtures and equipment schedule item supplier specification image WC2 Disabled Toilet
HaCaromarvey Norman Commercial
Cosmo Sovereign Care Toilet Suite
WELS 4 star rated
White Caravelle Care seat
Backrest
CODE: 987919BW
To be installed to comply with AS1428.1
GR2 Grab Rail Disabled Toilet
JD Macdonald
Grab Rail WC – Set 90 degrees (right handed)
CODE: GRC53 RH To be installed to comply with AS1428.1
WB3 Basin Disabled Toilet
Caroma Cube Care Wall Basin
Includes white plug and chrome waste
1 tap hole
Vitreous china, white only
CODE: 683515W
To be installed to comply with AS1428.1
TP2 Mixer Tap Disabled Toilet
Harvey Norman Commercial
Caroma Nordic Care Basin Mixer Hot/Cold - Chrome
CODE: 90965C5A
WELS 5 star rated
23 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
fittings fixtures and equipment schedule item supplier specification image M2 Mirror Disabled Toilet
Jubilee Framers
Safety Mirror mounted to wall to finish flush with tiles
600W x 1800H
BS Bench Seat
Laminex Laminex Change Bench Wall Mounted Size: 900W x 390D x 470H Finish: Oyster Linea Compact Laminate Qty = 1
TR Towel Rail
JD Macdonald
Double Towel Rail Chrome Plated Lilla Collection Code: 6810-14-81CP Size: 660W x 110 Projection
SHLF Shower Shelf
JD Macdonald
Shower Basket Size: 220L x 150W x 48D Chrome Finish Code: 6807-86
TRH Toilet Roll Holder
Supplied by GRC
HD1 Paper Towel Dispenser
Supplied by GRC
HK Multiple Hook
JD Macdonald
Utility Hook Strip 4 No. Hooks Size: 915L Code: 1307-4
24 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
signage item supplier specification image SN1 Amenities Signage Ground Floor
Pictobraille Entry Door Signage
Signage to Disabled WC to comply with AS1428.1 Code: PBS-AUAT Black on Silver Acrylic Mounted at 1200 to bottom of Braille
SN2 Amenities Signage Ground Floor
Pictobraille Signage to Ambulant WC to
comply with AS1428.1 Code: PBS-FMambT Black on Silver Acrylic Mounted at 1200 to bottom of Braille
SN3 Amenities Signage Ground Floor
Pictobraille Signage to Ambulant WC to
comply with AS1428.1 Code: PBS-MAmbT Black on Silver Acrylic Mounted at 1200 to bottom of Braille
SN4 Amenities Signage Ground Floor
Pictobraille Signage to Disabled WC to
comply with AS1428.1 Code: PBS-UATLH Black on Silver Acrylic Mounted at 1200 to bottom of Braille
SN5 Amenities Signage Level 1
Pictobraille Entry Door Signage
Signage to Female Toilets and Shower to comply with AS1428.1 Code: PBS-FTAS Black on Silver Acrylic Mounted at 1200 to bottom of Braille
25 GRC | 113 Goondoon Street, Gladstone TENDER ISSUE | 23/11/2012
signage item supplier specification image SN6 Amenities Signage Level 1
Pictobraille Entry Door Signage
Signage to Male Toilets and Shower to comply with AS1428.1 Code: PBS-MTAS Black on Silver Acrylic Mounted at 1200 to bottom of Braille
SN5 Shower Sign
Pictobraille Shower Sign Black on Silver Acrylic Code: PBS-S Mounted at 1200 to bottom of Braille
door schedule
CLIENT PROJECT NUMBER REVISION REVISION NOTES
400597 A FOR TENDER
D# LOCATION SIZE HARDWARE CODE QTY FINISH NOTES
D17 Customer Waiting 920 Full Height Aluminium Framed Glass Hinged Door Door Frames to suit Glazing Frame
1 Frame: Anodised Aluminium
Refer Assa Abloy Doors Schedule for Hardware & LockingWith Access control - refer Security DrawingsRefer Architectural drawings for glazing film details
D30 Meeting Room Operable Door
Lotus Operable Wall SystemOperable Wall Series OW-100F-45-SX2Panels shall be 100 series with fineline panel junctions1.6mm Flat Jamb to be usedPass door/ Expander PanelRW 49 Acoustic Rating
1 Finline frame:Anodised Aluminium
Door Hardware & Locking by Lotus DoorsRefer Architectural drawings for finishes elevations
920 opening
Single Hinged Doors Full height solid core doorsExternal Grade Door
1 PT2Door and Frame
Dulux Low VOC Semi Gloss Acrylic
Refer Assa Abloy Doors Schedule for Hardware & Locking
Satin Chrome
With Access control - refer Security Drawings
D1 External Door
GLADSTONE REGIONAL COUNCILNOTE: BUILDER TO REVIEW AND CHECK SCHEDULE FOR ACCURACY PRIOR TO ORDERING. BUILDER TO ENSURE HANDING. BUILDER TO CHECK CEILING HEIGHTS PRIOR TO ORDERING DOORS
7/11/2012 1 OF 2
door schedule
CLIENT PROJECT NUMBER REVISION REVISION NOTES
400597 A FOR TENDERGLADSTONE REGIONAL COUNCILNOTE: BUILDER TO REVIEW AND CHECK SCHEDULE FOR ACCURACY PRIOR TO ORDERING. BUILDER TO ENSURE HANDING. BUILDER TO CHECK CEILING HEIGHTS PRIOR TO ORDERING DOORS
D# LOCATION SIZE HARDWARE CODE QTY FINISH NOTES
920 opening
Single Hinged Doors Full height solid core doorsDoors to suitable for 2 hour fire rated room
1 PT2Door and Frame
Dulux Low VOC Semi Gloss Acrylic
Refer Assa Abloy Doors Schedule for Hardware & Locking
Satin Chrome
With Access control - refer Security Drawings Satin Chrome
920 Full height solid core door 14 PT2Door and Frame
Dulux Low VOC Semi Gloss Acrylic
Refer Assa Abloy Doors Schedule for Hardware & Locking
Satin Chrome
920 Full height solid core door 3 PT2Door and Frame
Dulux Low VOC Semi Gloss Acrylic
Refer Assa Abloy Doors Schedule for Hardware & Locking
Satin Chrome
With Access control - refer Security Drawings
920 min Full height solid core door 2 PT2Door and Frame
Dulux Low VOC Semi Gloss Acrylic
clear opening
Refer Assa Abloy Doors Schedule for Hardware & Locking
Satin Chrome
700 min Full height solid core door 5 PT2Door and Frame
Dulux Low VOC Semi Gloss Acrylic
clear opening
Refer Assa Abloy Doors Schedule for Hardware & Locking
Satin Chrome
to suit opening
Full height solid core door 2 PT2Door and Frame
Dulux Low VOC Semi Gloss Acrylic
Refer Assa Abloy Doors Schedule for Hardware & Locking
Satin Chrome
to suit opening
Full height solid core door 1 PT4Door and Frame
Dulux Low VOC Semi Gloss Acrylic
Refer Assa Abloy Doors Schedule for Hardware & Locking
Satin Chrome
D24, D32 FHR Cupboards
D9, D10, D25, D26,
D27
Toilet Doors
D8, D28 Disabled Toilet & Shower Doors
D12, D13, D14
General Office
D16 FHR Cupboards
General OfficeD2, D3, D4, D5, D6, D7, D11, D18, D19, D20, D21, D22,
D23
D29 Comms Room
7/11/2012 2 OF 2