Transcript
Page 1: Heat Pump - Piscine Atlantis PDF/Zodiac/brochure_Edenpac.pdf · Edenpac 2 single ph. Edenpac 3 single ph ... **** An annual check of the refrigerating circuit seal must be carried

Edenpac1, 2, 3, 4 & 5

Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com

Heat Pump

Technical specifications

Edenpac 1 single ph.*

Edenpac 2 single ph.

Edenpac 3 single ph.

Edenpac 3 triEdenpac 4 mono

Edenpac 5 tri

Performance conditions 1: Air 15° C /Water 24° C / Humidity 70% (Nominal Zodiac)

Consumed power (kW) 1,8 2,0 2,4 2,5 3,2 3,2

Operating power* (kW) 8,5 10 12 12 15 16

COP 4,7 4,9 5,0 4,9 4,8 5,0

Performances conditions 2 : Air 28° C / Eau 28° C / Hygro 80%

Operating power* (kW) 9,1 12,5 16 16 19,6 20,7

COP 5,1 5,8 5,7 5,7 5,5 5,9

Max pool volume (m3)* 0 to 55 45 to 70 60 to 85 60 to 85 75 to 110 100 to 120

Average water flow (m3/h) 5 5 5 5 6,5 6,5

Load loss (mCE) 1,3 1,3 1,3 1,3 1,7 1,7

Hydraulic connection PVC Ø 50 1/2 unions (glue)

Electric power 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz

Nominal absorbed intensity (A) 7,8 9,8 13 5,8 15,2 6

InMax absorbed intensity (A) 13,5 15 16 7 19 9

Power cable cross section (mm2)** 3 x 2,5 3 x 2,5 3 x 4 5 x 2,5 3 x 6 5 x 2,5

Acoustic power (dBA)*** 65,5 66,5 66,5 66,5 67,5 70

Acoustic pressure at 10 m. (dBA)*** 37,5 38,5 38,5 38,5 39,4 42

Weight (kg) 86 87 90 90 94 99

* Private pool with isothermal cover, from May 15 to September 15. Air at 15° C. ** For a maximum length of 25 metres.*** Values measured and certified according to the EN ISO 3741 and EN ISO 354 standards by the CTTM (Centre de Transfert de Technologie du Mans).

■ The most silent heat pump on the market

■ SCROLL Copeland compressor

■ Refrigerating fluid R 410 A

■ Heating priority function

■ Gradual starter (single phase models)

■ Ultra-robust

■ Wide range of powers

ACCESSORIES

Edenpac 1 single ph.*

Edenpac 2 single ph.

Edenpac 3 single ph.

Edenpac 3 triEdenpac 4 single ph.

Edenpac 5 tri

Standard model W20EDEN1M W20EDEN2M W20EDEN3M W20EDEN3T W20EDEN4M W20EDEN5T

Remote control module Wintering cover Cleaning Kit PAC Net

WCE03469 W20HOUSSEDEN WMA03491

The

* Model not continued available while stocks last: check availability with your sales contact.

Page 2: Heat Pump - Piscine Atlantis PDF/Zodiac/brochure_Edenpac.pdf · Edenpac 2 single ph. Edenpac 3 single ph ... **** An annual check of the refrigerating circuit seal must be carried

Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com

Edenpac 1, 2, 3, 4 & 5

EDENPAC

No obstacles for4 to 5 metres

WATERTREATMENT PUMP FILTER

0,50 mmini

BY-PASS

EXTRACTION REJECTS

INSTALLATION• Outside, close to the technical facility.

• Hydraulic connection using PVC Ø 50 by a filter by-pass (1/2 unions Ø 50 supplied).

• Plan for a gap of 50 cm between the back of the heat pump and the wall. There should be no obstacles in front of the machine for 4 to 5 metres (wall, hedge...).

• Electric power protected by a 30 mA ground fault circuit breaker (not supplied).

SIZE (in mm)

Digital display regulator

Ventilator (cold airblower)

Electric connection

terminals

Waterflow

detector

Pressure valve

SCROLL Compressor + coverTitanium

condenser

Pool wateroutletø 50

Air evaporatorr(ambient air intake)

Silent-blockPool waterintake ø 50

Cable-gland

DESCRIPTION

EQUIPMENT• Single block outdoor air/water heat pump.

• TITANIUM water exchanger condenser.

• High performance “thin plate” evaporator.

• Digital display regulator with on/off switch + indicators enabling priority heating.

• Remote control module (option).

• Very silent SCROLL compressor.

• Water flow controller.

• Water flow control using digital regulator.

• Phase detector (triphased model).

• HP and LP safety pressure switch.

• Automatic defrosting using forced ventilation.

• Anti-freeze thermostat (stops at + 5°C).

• Anti-corrosion casing.

• Refrigerating fluid R 410 A.

• Gradual starter (only on single phase models).

Page 3: Heat Pump - Piscine Atlantis PDF/Zodiac/brochure_Edenpac.pdf · Edenpac 2 single ph. Edenpac 3 single ph ... **** An annual check of the refrigerating circuit seal must be carried

Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com

Edenpac 6 tri **** Edenpac 7 single * Edenpac 8 tri ****

Standard model W20EDEN6T W20EDEN7M W20EDEN8T

Remote control module Edenpac double fan wintering cover Cleaning Kit PAC Net

WCE03469 W20HOUSSEDEN6 WMA03491

Edenpac6, 7 & 8

Technical specifications

Edenpac 6 tri Edenpac 7 single Edenpac 8 tri

Performance conditions 1 : Air 15° C / Water 24° C / Humidity 70% (Nominal Zodiac)

Consumed power* (kW) 4,0 4,8 5,5

Operating power* (kW) 21 24 28,5

COP 5,2 5,0 5,2

Performance conditions 2 : Air 28° C /Water 28° C / Humidity 80%

Operating power* (kW) 26,9 27,5 33,2

COP 6,0 5,6 5,6

Max pool volume (m3)* 110 to 160 100 to 180 140 to 200

Average water flow (m3/h) 6,5 6,5 6,5

Load loss (mCE) 1,1 1,1 1,1

Hydraulic connection PVC Ø 50 1/2 unions to glue

Electric power supply 400 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz

Nominal absorbed power (A) 7 26 10

Maximum absorbed intensity (A) 11 45 18

Power cable cross section (mm2)** 5 x 2,5 3 x 10 5 x 4

Acoustic power (dBA)*** 71,5 70 71,6

Acoustic pressure at 10 m. (dBA)*** 43,5 42 43,6

Weight (kg) 130 165 160

* Private pool with isothermal cover from May 15 to September 15. Air at 15° C.** For a maximum length of 25 metres.*** Values measured and certified according to EN ISO 3741 and EN ISO 354 standards by the CTTM (Centre de Transfert de Technologie du Mans).**** An annual check of the refrigerating circuit seal must be carried out for all refrigerating equipment of which the charge in refrigerating fluid is > than 2 kg and < than 30 kg(see art 3 of the 7/05/07 decree, French decree n° 737-2007)

ACCESSORIES

Heat Pump■ The most silent heat pump on the market

■ SCROLL Copeland compressor

■ Refrigerating fluid R 410 A

■ Priority heating function

■ Gradual start up (single phase model)

■ Ultra-robust

■ A wide range of powers

The

* Model not continued available while stocks last: check availability with your sales contact.

Page 4: Heat Pump - Piscine Atlantis PDF/Zodiac/brochure_Edenpac.pdf · Edenpac 2 single ph. Edenpac 3 single ph ... **** An annual check of the refrigerating circuit seal must be carried

Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com

Edenpac 6, 7 & 8

EDENPAC

0,50 mmini

BY-PASS

No obstacles for4 to 5 metres

WATERTREATMENT PUMP FILTER

EXTRACTION REJECTS

INSTALLATION• Outdoors, close to the technical facility.

• Hydraulic connection in PVC Ø 50 by filter by-pass (Ø 50 1/2 unions supplied).

• Plan a gap of 50 cm between the back of the heat pump and the wall. There should be no obstacles in front of the machine for 4 to 5 metres (wall, hedge...)

• Electric supply protected using a 30 mA ground fault circuit breaker (not supplied).

SIZE (in mm)

DESCRIPTION

EQUIPMENT• Single block outdoor air/water heat pump.

• TITANIUM water exchanger condenser.

• High performance “thin plate” evaporator.

• Digital display regulator with on/off switch + indicators with a heating priority function.

• Remote control module (option).

• Very silent SCROLL compressor.

• Water flow controller.

• Water flow controlled by the digital display.

• Phase detector (3 phase model)

• HP and LP safety pressure switch.

• Automatic defrosting using forced ventilation.

• Anti-freeze thermostat (stops at + 5°C).

• Anti-corrosion casing.

• Refrigerating fluid R 410 A.

• Gradual starter (only on single phase models).

Digital displayregulator

Electricplate

Titaniumwater

condenser

SCROLLCompressor

2 Ventilators(cold airblower

Poolwateroutletø 50

Air evaporator (ambient air intake)

Pool waterintakeø 50

Page 5: Heat Pump - Piscine Atlantis PDF/Zodiac/brochure_Edenpac.pdf · Edenpac 2 single ph. Edenpac 3 single ph ... **** An annual check of the refrigerating circuit seal must be carried

Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com

Edenpac 1 LT single

Edenpac 2 LT single

Edenpac 3 LT single

Edenpac 3 LT tri

Edenpac 4 LT single

Edenpac 5 LT tri

Standard model W20EDEN1IM W20EDEN2IM W20EDEN3IM W20EDEN3IT W20EDEN4IM W20EDEN5IT

Remote control module Cleaning Kit PAC Net

WCE03469 WMA03491

EdenpacIn technical facility

Heat Pump■ The most silent heat pump on the market

■ SCROLL Copeland compressor

■ Refrigerating fluid R 410 A

■ Maximum discretion(installation inside a closed room)

■ Heating priority function

■ Gradual start up (single phase models)

■ Ultra-robust

Technical specifications

Edenpac 1 LT single

Edenpac 2 LT single

Edenpac 3 LT single

Edenpac 3 LT tri

Edenpac 4 LT single

Edenpac 5 LT tri

Performance conditions 1 : Air 15° C / Water 24° C / Humidity 70% (Nominal Zodiac)

Consumed power* (kW) 1,8 2,0 2,4 2,5 3,2 3,2

Operating power* (kW) 8,5 10 12 12 15 16

COP 4,7 4,9 5,0 4,9 4,8 5,0

Performance conditions 2 : Air 28° C / Water 28° C / Humidity 80%

Operating power* (kW) 9,1 12,5 16 16 19,6 20,7

COP 5,1 5,8 5,7 5,7 5,5 5,9

Max pool volume (m3)* 0 to 55 45 to 70 60 to 85 60 to 85 75 to 110 100 to 120

Average water flow (m3/hr) 5 5 5 5 6,5 6,5

Load Loss (mCE) 1,3 1,3 1,3 1,3 1,7 1,7

Hydraulic connection PVC Ø 50 1/2 unions to glue

Air flow (m3/hr) 2500 2500 2500 2500 2500 2500

Electric power 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz

Nominal absorbed power (A) 7,8 9,6 13 5,8 15,2 6

Maximum absorbed power (A) 13,5 15 13 7 19 9

Power cable cross section (mm2)** 3 x 2,5 3 x 2,5 3 x 4 5 x 2,5 3 x 6 5 x 2,5

Acoustic power 65,5 66,5 66,5 66,5 67,5 70

Acoustic power at 10m 37,5 38,5 38,5 38,5 39,4 42

Weight (kg) 86 87 90 90 94 99

* Depending on climatic zone for private open air pools from 15.05 to 15.09 with isothermal cover. ** For a maximum length of 25 metres.

ACCESSORIES

The

Page 6: Heat Pump - Piscine Atlantis PDF/Zodiac/brochure_Edenpac.pdf · Edenpac 2 single ph. Edenpac 3 single ph ... **** An annual check of the refrigerating circuit seal must be carried

Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com

Edenpac In technical facility

INSTALLATION• In a technical facility using the kit including the

grate and the duct to intake outside air and reject cold air outside.

• Hydraulic connection PVC Ø 50 by filter by-pass (1/2 Ø 50 unions supplied).

• Plan a gap of 50 cm between the back of the heat pump and the wall.

• Electric power protected by a 30 mA ground fault circuit breaker on the line head (not supplied).

• Plan to evacuate condensation.

SIZE (in mm)

DESCRIPTION

EQUIPEMENTS• Single block indoor air/water heat pump

to be installed in a technical room using the kit containing 2 grates and 2 adapters and insulated Ø 500 3 m duct.

• TITANIUM water exchanger condenser.

• High performance “thin plate” evaporator. • Digital display regulator with on/off switch

+ indicators with heating priority.

• Very silent SCROLL compressor.

• Fan ventilator.

• Water flow control.

• Water flow control using the digital display.

• Phase detector (3 phase model).

• Safety pressostat LP and HP.

• Automatic defrosting by forced ventilation.

• Anti-freeze thermostat (stops at + 5°C outside temp.).

• Anti-corrosion casing.

• Refrigerating fluid R 410 A.

• Gradual start up (only on single phase models).

BY-PASS

watertreatmentInsulated

cold aIrrejectIon

Ø 500

outsIdeaIr Intake

grate500 x 500

grate500 x 500

rejectIonextractIon

fIlterpump

1190

81095

ø 500

190

34560

735488

104140

Outdoor airintake grate500 x 500

Cold air rejectiongrate 500 x 500

Digital displayregulatorEVK

Electric plate

Waterflow

controller

Pressure valve

SCROLL compressor + cover

TITANIUM water

condenser

InsulatedØ 500 mm

duct