heat pump - piscine atlantis pdf/zodiac/brochure_edenpac.pdf · edenpac 2 single ph. edenpac 3...
TRANSCRIPT
Edenpac1, 2, 3, 4 & 5
Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com
Heat Pump
Technical specifications
Edenpac 1 single ph.*
Edenpac 2 single ph.
Edenpac 3 single ph.
Edenpac 3 triEdenpac 4 mono
Edenpac 5 tri
Performance conditions 1: Air 15° C /Water 24° C / Humidity 70% (Nominal Zodiac)
Consumed power (kW) 1,8 2,0 2,4 2,5 3,2 3,2
Operating power* (kW) 8,5 10 12 12 15 16
COP 4,7 4,9 5,0 4,9 4,8 5,0
Performances conditions 2 : Air 28° C / Eau 28° C / Hygro 80%
Operating power* (kW) 9,1 12,5 16 16 19,6 20,7
COP 5,1 5,8 5,7 5,7 5,5 5,9
Max pool volume (m3)* 0 to 55 45 to 70 60 to 85 60 to 85 75 to 110 100 to 120
Average water flow (m3/h) 5 5 5 5 6,5 6,5
Load loss (mCE) 1,3 1,3 1,3 1,3 1,7 1,7
Hydraulic connection PVC Ø 50 1/2 unions (glue)
Electric power 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz
Nominal absorbed intensity (A) 7,8 9,8 13 5,8 15,2 6
InMax absorbed intensity (A) 13,5 15 16 7 19 9
Power cable cross section (mm2)** 3 x 2,5 3 x 2,5 3 x 4 5 x 2,5 3 x 6 5 x 2,5
Acoustic power (dBA)*** 65,5 66,5 66,5 66,5 67,5 70
Acoustic pressure at 10 m. (dBA)*** 37,5 38,5 38,5 38,5 39,4 42
Weight (kg) 86 87 90 90 94 99
* Private pool with isothermal cover, from May 15 to September 15. Air at 15° C. ** For a maximum length of 25 metres.*** Values measured and certified according to the EN ISO 3741 and EN ISO 354 standards by the CTTM (Centre de Transfert de Technologie du Mans).
■ The most silent heat pump on the market
■ SCROLL Copeland compressor
■ Refrigerating fluid R 410 A
■ Heating priority function
■ Gradual starter (single phase models)
■ Ultra-robust
■ Wide range of powers
ACCESSORIES
Edenpac 1 single ph.*
Edenpac 2 single ph.
Edenpac 3 single ph.
Edenpac 3 triEdenpac 4 single ph.
Edenpac 5 tri
Standard model W20EDEN1M W20EDEN2M W20EDEN3M W20EDEN3T W20EDEN4M W20EDEN5T
Remote control module Wintering cover Cleaning Kit PAC Net
WCE03469 W20HOUSSEDEN WMA03491
The
* Model not continued available while stocks last: check availability with your sales contact.
Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com
Edenpac 1, 2, 3, 4 & 5
EDENPAC
No obstacles for4 to 5 metres
WATERTREATMENT PUMP FILTER
0,50 mmini
BY-PASS
EXTRACTION REJECTS
INSTALLATION• Outside, close to the technical facility.
• Hydraulic connection using PVC Ø 50 by a filter by-pass (1/2 unions Ø 50 supplied).
• Plan for a gap of 50 cm between the back of the heat pump and the wall. There should be no obstacles in front of the machine for 4 to 5 metres (wall, hedge...).
• Electric power protected by a 30 mA ground fault circuit breaker (not supplied).
SIZE (in mm)
Digital display regulator
Ventilator (cold airblower)
Electric connection
terminals
Waterflow
detector
Pressure valve
SCROLL Compressor + coverTitanium
condenser
Pool wateroutletø 50
Air evaporatorr(ambient air intake)
Silent-blockPool waterintake ø 50
Cable-gland
DESCRIPTION
EQUIPMENT• Single block outdoor air/water heat pump.
• TITANIUM water exchanger condenser.
• High performance “thin plate” evaporator.
• Digital display regulator with on/off switch + indicators enabling priority heating.
• Remote control module (option).
• Very silent SCROLL compressor.
• Water flow controller.
• Water flow control using digital regulator.
• Phase detector (triphased model).
• HP and LP safety pressure switch.
• Automatic defrosting using forced ventilation.
• Anti-freeze thermostat (stops at + 5°C).
• Anti-corrosion casing.
• Refrigerating fluid R 410 A.
• Gradual starter (only on single phase models).
Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com
Edenpac 6 tri **** Edenpac 7 single * Edenpac 8 tri ****
Standard model W20EDEN6T W20EDEN7M W20EDEN8T
Remote control module Edenpac double fan wintering cover Cleaning Kit PAC Net
WCE03469 W20HOUSSEDEN6 WMA03491
Edenpac6, 7 & 8
Technical specifications
Edenpac 6 tri Edenpac 7 single Edenpac 8 tri
Performance conditions 1 : Air 15° C / Water 24° C / Humidity 70% (Nominal Zodiac)
Consumed power* (kW) 4,0 4,8 5,5
Operating power* (kW) 21 24 28,5
COP 5,2 5,0 5,2
Performance conditions 2 : Air 28° C /Water 28° C / Humidity 80%
Operating power* (kW) 26,9 27,5 33,2
COP 6,0 5,6 5,6
Max pool volume (m3)* 110 to 160 100 to 180 140 to 200
Average water flow (m3/h) 6,5 6,5 6,5
Load loss (mCE) 1,1 1,1 1,1
Hydraulic connection PVC Ø 50 1/2 unions to glue
Electric power supply 400 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz
Nominal absorbed power (A) 7 26 10
Maximum absorbed intensity (A) 11 45 18
Power cable cross section (mm2)** 5 x 2,5 3 x 10 5 x 4
Acoustic power (dBA)*** 71,5 70 71,6
Acoustic pressure at 10 m. (dBA)*** 43,5 42 43,6
Weight (kg) 130 165 160
* Private pool with isothermal cover from May 15 to September 15. Air at 15° C.** For a maximum length of 25 metres.*** Values measured and certified according to EN ISO 3741 and EN ISO 354 standards by the CTTM (Centre de Transfert de Technologie du Mans).**** An annual check of the refrigerating circuit seal must be carried out for all refrigerating equipment of which the charge in refrigerating fluid is > than 2 kg and < than 30 kg(see art 3 of the 7/05/07 decree, French decree n° 737-2007)
ACCESSORIES
Heat Pump■ The most silent heat pump on the market
■ SCROLL Copeland compressor
■ Refrigerating fluid R 410 A
■ Priority heating function
■ Gradual start up (single phase model)
■ Ultra-robust
■ A wide range of powers
The
* Model not continued available while stocks last: check availability with your sales contact.
Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com
Edenpac 6, 7 & 8
EDENPAC
0,50 mmini
BY-PASS
No obstacles for4 to 5 metres
WATERTREATMENT PUMP FILTER
EXTRACTION REJECTS
INSTALLATION• Outdoors, close to the technical facility.
• Hydraulic connection in PVC Ø 50 by filter by-pass (Ø 50 1/2 unions supplied).
• Plan a gap of 50 cm between the back of the heat pump and the wall. There should be no obstacles in front of the machine for 4 to 5 metres (wall, hedge...)
• Electric supply protected using a 30 mA ground fault circuit breaker (not supplied).
SIZE (in mm)
DESCRIPTION
EQUIPMENT• Single block outdoor air/water heat pump.
• TITANIUM water exchanger condenser.
• High performance “thin plate” evaporator.
• Digital display regulator with on/off switch + indicators with a heating priority function.
• Remote control module (option).
• Very silent SCROLL compressor.
• Water flow controller.
• Water flow controlled by the digital display.
• Phase detector (3 phase model)
• HP and LP safety pressure switch.
• Automatic defrosting using forced ventilation.
• Anti-freeze thermostat (stops at + 5°C).
• Anti-corrosion casing.
• Refrigerating fluid R 410 A.
• Gradual starter (only on single phase models).
Digital displayregulator
Electricplate
Titaniumwater
condenser
SCROLLCompressor
2 Ventilators(cold airblower
Poolwateroutletø 50
Air evaporator (ambient air intake)
Pool waterintakeø 50
Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com
Edenpac 1 LT single
Edenpac 2 LT single
Edenpac 3 LT single
Edenpac 3 LT tri
Edenpac 4 LT single
Edenpac 5 LT tri
Standard model W20EDEN1IM W20EDEN2IM W20EDEN3IM W20EDEN3IT W20EDEN4IM W20EDEN5IT
Remote control module Cleaning Kit PAC Net
WCE03469 WMA03491
EdenpacIn technical facility
Heat Pump■ The most silent heat pump on the market
■ SCROLL Copeland compressor
■ Refrigerating fluid R 410 A
■ Maximum discretion(installation inside a closed room)
■ Heating priority function
■ Gradual start up (single phase models)
■ Ultra-robust
Technical specifications
Edenpac 1 LT single
Edenpac 2 LT single
Edenpac 3 LT single
Edenpac 3 LT tri
Edenpac 4 LT single
Edenpac 5 LT tri
Performance conditions 1 : Air 15° C / Water 24° C / Humidity 70% (Nominal Zodiac)
Consumed power* (kW) 1,8 2,0 2,4 2,5 3,2 3,2
Operating power* (kW) 8,5 10 12 12 15 16
COP 4,7 4,9 5,0 4,9 4,8 5,0
Performance conditions 2 : Air 28° C / Water 28° C / Humidity 80%
Operating power* (kW) 9,1 12,5 16 16 19,6 20,7
COP 5,1 5,8 5,7 5,7 5,5 5,9
Max pool volume (m3)* 0 to 55 45 to 70 60 to 85 60 to 85 75 to 110 100 to 120
Average water flow (m3/hr) 5 5 5 5 6,5 6,5
Load Loss (mCE) 1,3 1,3 1,3 1,3 1,7 1,7
Hydraulic connection PVC Ø 50 1/2 unions to glue
Air flow (m3/hr) 2500 2500 2500 2500 2500 2500
Electric power 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz
Nominal absorbed power (A) 7,8 9,6 13 5,8 15,2 6
Maximum absorbed power (A) 13,5 15 13 7 19 9
Power cable cross section (mm2)** 3 x 2,5 3 x 2,5 3 x 4 5 x 2,5 3 x 6 5 x 2,5
Acoustic power 65,5 66,5 66,5 66,5 67,5 70
Acoustic power at 10m 37,5 38,5 38,5 38,5 39,4 42
Weight (kg) 86 87 90 90 94 99
* Depending on climatic zone for private open air pools from 15.05 to 15.09 with isothermal cover. ** For a maximum length of 25 metres.
ACCESSORIES
The
Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com
Edenpac In technical facility
INSTALLATION• In a technical facility using the kit including the
grate and the duct to intake outside air and reject cold air outside.
• Hydraulic connection PVC Ø 50 by filter by-pass (1/2 Ø 50 unions supplied).
• Plan a gap of 50 cm between the back of the heat pump and the wall.
• Electric power protected by a 30 mA ground fault circuit breaker on the line head (not supplied).
• Plan to evacuate condensation.
SIZE (in mm)
DESCRIPTION
EQUIPEMENTS• Single block indoor air/water heat pump
to be installed in a technical room using the kit containing 2 grates and 2 adapters and insulated Ø 500 3 m duct.
• TITANIUM water exchanger condenser.
• High performance “thin plate” evaporator. • Digital display regulator with on/off switch
+ indicators with heating priority.
• Very silent SCROLL compressor.
• Fan ventilator.
• Water flow control.
• Water flow control using the digital display.
• Phase detector (3 phase model).
• Safety pressostat LP and HP.
• Automatic defrosting by forced ventilation.
• Anti-freeze thermostat (stops at + 5°C outside temp.).
• Anti-corrosion casing.
• Refrigerating fluid R 410 A.
• Gradual start up (only on single phase models).
BY-PASS
watertreatmentInsulated
cold aIrrejectIon
Ø 500
outsIdeaIr Intake
grate500 x 500
grate500 x 500
rejectIonextractIon
fIlterpump
1190
81095
ø 500
190
34560
735488
104140
Outdoor airintake grate500 x 500
Cold air rejectiongrate 500 x 500
Digital displayregulatorEVK
Electric plate
Waterflow
controller
Pressure valve
SCROLL compressor + cover
TITANIUM water
condenser
InsulatedØ 500 mm
duct