Transcript
Page 1: Hipharma STATIC PASS BOX - Nicomac · 2019-01-28 · Hipharma STATIC PASS BOX STATIC pass boxes are consisting of: • St.st. AISI304 chamber • Two-glass doors complete with fixed

Hipharma STATIC PASS BOX

STATIC pass boxes are consisting of:• St.st. AISI304 chamber• Two-glass doors complete with fixed knob.

Glass is 3+3/32/3+3 type• Mechanical interlocking system

Optional:• Door interlocking system with PLC

STATIC pass boxes are available in the following sizes:• 300x300x300mm• 450x450x450mm• 600x600x600mm• 800x800x800mm• 1000x1000x1000mm• 1000x1000x1200mm• 800x800x1500mm• 900x900x900mm• 900x1220x1200mm

STAINLESS STEEL AISI 304 STANDARDS

Hardness 80(20) HRB max EN 1.4301(II)

Density 7,9 kg/dm3 at 20C° EN 1.4301(I)

Elasticity modulus 200 kN/mm2 at 20°C EN 1.4301(I)

Average thermal expansion coefficient

16,5 [10-6xK-1] (20°C ÷ 200°C)

17,5 [10-6xK-1] (20°C ÷ 400°C)

EN 1.4301(I)

EN 1.4301(I)

Thermal conductivity 15 [W/(mxK)] at 20°C EN 1.4301(I)

Specific heat 500 [J/(kgxK)] at 20°C EN 1.4301(I)

Electrical resistance 0,73 [(Ωxmm2)/m] at 20°C EN 1.4301(I)

LAMINATED SAFETY GLASS

AVCP SYSTEMS

PERFORMANCES STANDARDS

Resistance to fire 1 NPD EN 14449:2005+AC:2005

Reaction to fire 3,4 NPD EN 14449:2005+AC:2005

External fire performance

3,4 NPD EN 14449:2005+AC:2005

Declared emission εd 3 0,89 EN 14449:2005+AC:2005

U-value W/(m2.K) 3 NPD EN 14449:2005+AC:2005

Light transmittance τV 3 NPD EN 14449:2005+AC:2005

Light reflectance ρV/ρ’V 3 NPD EN 14449:2005+AC:2005

Durability 3 PASS EN 14449:2005+AC:2005

Designed by Nicomac | www.nicomac.comNicomac reserves the right to change the submitted technical data

Data in this catalogue are not binding | Issued on 04.2018

NICOMAC EUROPE [email protected] GROUP [email protected] FAR EAST [email protected] 1

Page 2: Hipharma STATIC PASS BOX - Nicomac · 2019-01-28 · Hipharma STATIC PASS BOX STATIC pass boxes are consisting of: • St.st. AISI304 chamber • Two-glass doors complete with fixed

Hipharma VENTILATED PASS BOX

VENTILATED pass boxes are consisting of:• St.st. AISI304 chamber• Two-glass doors complete with fixed knob. Glass is

3+3/32/3+3 type• Door interlocking system• AISI304 st.st. perforated bottom side for return air• H5 H15 filters

Optional:• Light fixture• UV lamp

VENTILATED pass boxes are available in the following sizes:• 300x300x300mm• 450x450x450mm• 600x600x600mm• 800x800x800mm• 1000x1000x1000mm• 1000x1000x1200mm• 800x800x1500mm• 900x900x900mm• 900x1220x1200mm

STAINLESS STEEL AISI 304 STANDARDS

Hardness 80(20) HRB max EN 1.4301(II)

Density 7,9 kg/dm3 at 20C° EN 1.4301(I)

Elasticity modulus 200 kN/mm2 at 20°C EN 1.4301(I)

Average thermal expansion coefficient

16,5 [10-6xK-1] (20°C ÷ 200°C)

17,5 [10-6xK-1] (20°C ÷ 400°C)

EN 1.4301(I)

EN 1.4301(I)

Thermal conductivity 15 [W/(mxK)] at 20°C EN 1.4301(I)

Specific heat 500 [J/(kgxK)] at 20°C EN 1.4301(I)

Electrical resistance 0,73 [(Ωxmm2)/m] at 20°C EN 1.4301(I)

LAMINATED SAFETY GLASS

AVCP SYSTEMS

PERFORMANCES STANDARDS

Resistance to fire 1 NPD EN 14449:2005+AC:2005

Reaction to fire 3,4 NPD EN 14449:2005+AC:2005

External fire performance

3,4 NPD EN 14449:2005+AC:2005

Declared emission εd 3 0,89 EN 14449:2005+AC:2005

U-value W/(m2.K) 3 NPD EN 14449:2005+AC:2005

Light transmittance τV 3 NPD EN 14449:2005+AC:2005

Light reflectance ρV/ρ’V 3 NPD EN 14449:2005+AC:2005

Durability 3 PASS EN 14449:2005+AC:2005

AISI304 st.st. perforated bottom side for return air

H5 H15 filters Pass box wing

Designed by Nicomac | www.nicomac.comNicomac reserves the right to change the submitted technical data

Data in this catalogue are not binding | Issued on 04.2018

NICOMAC EUROPE [email protected] GROUP [email protected] FAR EAST [email protected] 2

Page 3: Hipharma STATIC PASS BOX - Nicomac · 2019-01-28 · Hipharma STATIC PASS BOX STATIC pass boxes are consisting of: • St.st. AISI304 chamber • Two-glass doors complete with fixed

Hipharma DYNAMIC PASS BOX

DYNAMIC pass boxes are consisting of:• St.st. AISI304 chamber• Two-glass doors complete with fixed

knob. Glass is 3+3/32/3+3 type• Door interlocking system with PLC• AISI304 st.st. box for filters H5 and

H15• Electrical board• H5 H15 filters• Humidity sensor• Light fixtures• Fan

Optional:• UV lamp

DYNAMIC pass boxes are available in the following sizes: • 300x300x300mm• 450x450x450mm• 600x600x600mm• 800x800x800mm• 1000x1000x1000mm• 1000x1000x1200mm• 800x800x1500mm• 900x900x900mm• 900x1220x1200mm

STAINLESS STEEL AISI 304 STANDARDS

Hardness 80(20) HRB max EN 1.4301(II)

Density 7,9 kg/dm3 at 20C° EN 1.4301(I)

Elasticity modulus 200 kN/mm2 at 20°C EN 1.4301(I)

Average thermal expansion coefficient

16,5 [10-6xK-1] (20°C ÷ 200°C)

17,5 [10-6xK-1] (20°C ÷ 400°C)

EN 1.4301(I)

EN 1.4301(I)

Thermal conductivity 15 [W/(mxK)] at 20°C EN 1.4301(I)

Specific heat 500 [J/(kgxK)] at 20°C EN 1.4301(I)

Electrical resistance 0,73 [(Ωxmm2)/m] at 20°C EN 1.4301(I)

LAMINATED SAFETY GLASS

AVCP SYSTEMS

PERFORMANCES STANDARDS

Resistance to fire 1 NPD EN 14449:2005+AC:2005

Reaction to fire 3,4 NPD EN 14449:2005+AC:2005

External fire performance

3,4 NPD EN 14449:2005+AC:2005

Declared emission εd 3 0,89 EN 14449:2005+AC:2005

U-value W/(m2.K) 3 NPD EN 14449:2005+AC:2005

Light transmittance τV 3 NPD EN 14449:2005+AC:2005

Light reflectance ρV/ρ’V 3 NPD EN 14449:2005+AC:2005

Durability 3 PASS EN 14449:2005+AC:2005

Designed by Nicomac | www.nicomac.comNicomac reserves the right to change the submitted technical data

Data in this catalogue are not binding | Issued on 04.2018

NICOMAC EUROPE [email protected] GROUP [email protected] FAR EAST [email protected] 3

Page 4: Hipharma STATIC PASS BOX - Nicomac · 2019-01-28 · Hipharma STATIC PASS BOX STATIC pass boxes are consisting of: • St.st. AISI304 chamber • Two-glass doors complete with fixed

Hipharma SPECIAL PASS BOX

LEXAN PASS BOXspecial version

LEXAN PASS BOX

FALSE PASS BOXencased in false column

ISOLATOR WITH NICOMAC WALL AND PASS BOX

PASS BOXcomplete with UV lamps

PASS THROUGH

Designed by Nicomac | www.nicomac.comNicomac reserves the right to change the submitted technical data

Data in this catalogue are not binding | Issued on 04.2018

NICOMAC EUROPE [email protected] GROUP [email protected] FAR EAST [email protected] 4