Hipharma STATIC PASS BOX
STATIC pass boxes are consisting of:• St.st. AISI304 chamber• Two-glass doors complete with fixed knob.
Glass is 3+3/32/3+3 type• Mechanical interlocking system
Optional:• Door interlocking system with PLC
STATIC pass boxes are available in the following sizes:• 300x300x300mm• 450x450x450mm• 600x600x600mm• 800x800x800mm• 1000x1000x1000mm• 1000x1000x1200mm• 800x800x1500mm• 900x900x900mm• 900x1220x1200mm
STAINLESS STEEL AISI 304 STANDARDS
Hardness 80(20) HRB max EN 1.4301(II)
Density 7,9 kg/dm3 at 20C° EN 1.4301(I)
Elasticity modulus 200 kN/mm2 at 20°C EN 1.4301(I)
Average thermal expansion coefficient
16,5 [10-6xK-1] (20°C ÷ 200°C)
17,5 [10-6xK-1] (20°C ÷ 400°C)
EN 1.4301(I)
EN 1.4301(I)
Thermal conductivity 15 [W/(mxK)] at 20°C EN 1.4301(I)
Specific heat 500 [J/(kgxK)] at 20°C EN 1.4301(I)
Electrical resistance 0,73 [(Ωxmm2)/m] at 20°C EN 1.4301(I)
LAMINATED SAFETY GLASS
AVCP SYSTEMS
PERFORMANCES STANDARDS
Resistance to fire 1 NPD EN 14449:2005+AC:2005
Reaction to fire 3,4 NPD EN 14449:2005+AC:2005
External fire performance
3,4 NPD EN 14449:2005+AC:2005
Declared emission εd 3 0,89 EN 14449:2005+AC:2005
U-value W/(m2.K) 3 NPD EN 14449:2005+AC:2005
Light transmittance τV 3 NPD EN 14449:2005+AC:2005
Light reflectance ρV/ρ’V 3 NPD EN 14449:2005+AC:2005
Durability 3 PASS EN 14449:2005+AC:2005
Designed by Nicomac | www.nicomac.comNicomac reserves the right to change the submitted technical data
Data in this catalogue are not binding | Issued on 04.2018
NICOMAC EUROPE [email protected] GROUP [email protected] FAR EAST [email protected] 1
Hipharma VENTILATED PASS BOX
VENTILATED pass boxes are consisting of:• St.st. AISI304 chamber• Two-glass doors complete with fixed knob. Glass is
3+3/32/3+3 type• Door interlocking system• AISI304 st.st. perforated bottom side for return air• H5 H15 filters
Optional:• Light fixture• UV lamp
VENTILATED pass boxes are available in the following sizes:• 300x300x300mm• 450x450x450mm• 600x600x600mm• 800x800x800mm• 1000x1000x1000mm• 1000x1000x1200mm• 800x800x1500mm• 900x900x900mm• 900x1220x1200mm
STAINLESS STEEL AISI 304 STANDARDS
Hardness 80(20) HRB max EN 1.4301(II)
Density 7,9 kg/dm3 at 20C° EN 1.4301(I)
Elasticity modulus 200 kN/mm2 at 20°C EN 1.4301(I)
Average thermal expansion coefficient
16,5 [10-6xK-1] (20°C ÷ 200°C)
17,5 [10-6xK-1] (20°C ÷ 400°C)
EN 1.4301(I)
EN 1.4301(I)
Thermal conductivity 15 [W/(mxK)] at 20°C EN 1.4301(I)
Specific heat 500 [J/(kgxK)] at 20°C EN 1.4301(I)
Electrical resistance 0,73 [(Ωxmm2)/m] at 20°C EN 1.4301(I)
LAMINATED SAFETY GLASS
AVCP SYSTEMS
PERFORMANCES STANDARDS
Resistance to fire 1 NPD EN 14449:2005+AC:2005
Reaction to fire 3,4 NPD EN 14449:2005+AC:2005
External fire performance
3,4 NPD EN 14449:2005+AC:2005
Declared emission εd 3 0,89 EN 14449:2005+AC:2005
U-value W/(m2.K) 3 NPD EN 14449:2005+AC:2005
Light transmittance τV 3 NPD EN 14449:2005+AC:2005
Light reflectance ρV/ρ’V 3 NPD EN 14449:2005+AC:2005
Durability 3 PASS EN 14449:2005+AC:2005
AISI304 st.st. perforated bottom side for return air
H5 H15 filters Pass box wing
Designed by Nicomac | www.nicomac.comNicomac reserves the right to change the submitted technical data
Data in this catalogue are not binding | Issued on 04.2018
NICOMAC EUROPE [email protected] GROUP [email protected] FAR EAST [email protected] 2
Hipharma DYNAMIC PASS BOX
DYNAMIC pass boxes are consisting of:• St.st. AISI304 chamber• Two-glass doors complete with fixed
knob. Glass is 3+3/32/3+3 type• Door interlocking system with PLC• AISI304 st.st. box for filters H5 and
H15• Electrical board• H5 H15 filters• Humidity sensor• Light fixtures• Fan
Optional:• UV lamp
DYNAMIC pass boxes are available in the following sizes: • 300x300x300mm• 450x450x450mm• 600x600x600mm• 800x800x800mm• 1000x1000x1000mm• 1000x1000x1200mm• 800x800x1500mm• 900x900x900mm• 900x1220x1200mm
STAINLESS STEEL AISI 304 STANDARDS
Hardness 80(20) HRB max EN 1.4301(II)
Density 7,9 kg/dm3 at 20C° EN 1.4301(I)
Elasticity modulus 200 kN/mm2 at 20°C EN 1.4301(I)
Average thermal expansion coefficient
16,5 [10-6xK-1] (20°C ÷ 200°C)
17,5 [10-6xK-1] (20°C ÷ 400°C)
EN 1.4301(I)
EN 1.4301(I)
Thermal conductivity 15 [W/(mxK)] at 20°C EN 1.4301(I)
Specific heat 500 [J/(kgxK)] at 20°C EN 1.4301(I)
Electrical resistance 0,73 [(Ωxmm2)/m] at 20°C EN 1.4301(I)
LAMINATED SAFETY GLASS
AVCP SYSTEMS
PERFORMANCES STANDARDS
Resistance to fire 1 NPD EN 14449:2005+AC:2005
Reaction to fire 3,4 NPD EN 14449:2005+AC:2005
External fire performance
3,4 NPD EN 14449:2005+AC:2005
Declared emission εd 3 0,89 EN 14449:2005+AC:2005
U-value W/(m2.K) 3 NPD EN 14449:2005+AC:2005
Light transmittance τV 3 NPD EN 14449:2005+AC:2005
Light reflectance ρV/ρ’V 3 NPD EN 14449:2005+AC:2005
Durability 3 PASS EN 14449:2005+AC:2005
Designed by Nicomac | www.nicomac.comNicomac reserves the right to change the submitted technical data
Data in this catalogue are not binding | Issued on 04.2018
NICOMAC EUROPE [email protected] GROUP [email protected] FAR EAST [email protected] 3
Hipharma SPECIAL PASS BOX
LEXAN PASS BOXspecial version
LEXAN PASS BOX
FALSE PASS BOXencased in false column
ISOLATOR WITH NICOMAC WALL AND PASS BOX
PASS BOXcomplete with UV lamps
PASS THROUGH
Designed by Nicomac | www.nicomac.comNicomac reserves the right to change the submitted technical data
Data in this catalogue are not binding | Issued on 04.2018
NICOMAC EUROPE [email protected] GROUP [email protected] FAR EAST [email protected] 4