Optilift iNOC ( Net Oil Computer)
PUBLIC INFORMATION
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION 2
Agenda
HMI Screens
Features
Overview
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
Overview
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
The Rockwell Automation iNOC (Intelligent Net Oil Computer) is an advanced design controller for Well Testing. It could be installed at the liquid leg of a two or three phase test separator.It is based on an Intelligent RTU technology to perform required calculation in Real Time on site and transmit the data to any pre-defined location.The iNOC controls the testing sequence though a Multi - Port Selector Valve (MSV) and calculate the Oil and Water Volumes, Flow Rates and Water Cut at Line and at Reference Conditions.The solution uses Line Pressure, Line Temperature and CoriolisMass Flow Meter signals as input data to perform the calculations. A Water Cut Meter could be included to improve the accuracy of the Well Test.
iNOCOverview
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
It guarantees the Well Test performance even if communication issue is experienced.
Calculate the Water Volume at Line Condition when a Water Cut Meter is not present.
Automatically detects MSV leaking. Save cost on personnel mobilization because the Well Test
sequence could be controlled remotely. Save cost of laboratory test to determine the Water Cut
because it is calculated on line.
iNOCBenefits
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
iNOCSystem Schematic
Pressure
Transmitter
Multi Port Selector Valve
(MSV)
Coriolis
Flowmeter
Water Cut
Meter
Net Oil Computer
iNOC
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
RTU KERNEL
MESSAGE
LOGGER
DATA
LOGGER
AGA
BHP
TCP MASTER
WEB SERVER
REPORT
GENERATOR
WET GAS
DETECTION
OPC
SERVER
ISAGRAFREPORT
MAILER
TCP SLAVE
RTU MASTER
RTU SLAVE
PID
ALARM MANAGER
I/O CARD
iXC2 RTULinux Architecture
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
iXC2 RTUiNOC Application
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
Features
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION 10
iNOCFeatures Determines the Volume, Flow Rate and Water Cut using
the American Petroleum Institute (API) Manual of Petroleum Measurement Standards, Chapters 11, Section 1 and Allocation Measurement, Chapter 20, Section 1.
Offers two calculation methods: Without Water Cut Meter input or with Water Cut Meter input from the measuring location in the field.
Can extrapolate to 24 hours the Oil and Water Volume measured during any test period.
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION 11
iNOCFeatures
Could be used to test a single well or several wells connected to a MSV.
Controls the test sequence of seven well depending on the number of MSV ports.
Store up to seven well tests per well for the last seven tests. Support several MSV models from different manufacturers. Perform automatic MSV leak test.
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION 12
iNOCFeatures Displays the trends of Oil and Water Flow Rates and Water
Cut. As a user - friendly Human Machine Interface (HMI) for easy
configuration. It has the option of selecting Oilfield, International System of
Units (SI) or customary units of measurement for input, calculated and output parameters.
It has alarms and warnings when the operating conditions are out of range.
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION 13
iNOCInput Data
Pressure and Temperature at Reference Condition. Density of the Oil and the Water at Reference Condition. Pressure and Temperature at Line Condition. Density of the Mixture of Oil and Water at Line Condition. Water Cut at Line Condition (Optional).
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION 14
iNOCOutput Data
Instantaneous, Average and Total Oil and Water Volume at Line Conditions.
Instantaneous, Average and Total Oil and Water Volume at Reference Conditions.
Instantaneous, Average and Total Water Cut at Line and Reference Conditions.
Instantaneous and Average Density of Oil and Water at Line Conditions.
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
iNOCReport Generation
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
Typical Well Test SkidFront View
iNOC
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
Typical Well Test SkidSide View
iNOC
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
HMI Screens
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
iNOCMain Screen
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
iNOCConfiguration
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
iNOCReport
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.PUBLIC INFORMATION
iNOCAlarms
-
Copyright 2014 Rockwell Automation, Inc. All rights reserved.