Download - Interface b Connectors
-
Catalogue 2011
a Nexans company
-
202/2
011
While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve.
EUROMOLDEuromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber connectors for cables and epoxy bushings for transformers and switchgear, as well as a large range of cold-shrinkable terminations and joints from 12 to 42 kV.Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group.
ISO 9001 CertificateSince 1992, Euromolds commitment to quality is demonstrated by its ISO 9001 certification.
Laboratory accreditationSince June 2000, Euromolds independent ELAB laboratory obtained the BELAC accreditation no.144-TEST conform with the European standards for laboratories ISO 17025 for electrical testing of low and medium voltage cable accessories according to the international standards HD 623 and HD 629.
International standardsAll our products meet the International standards like CENELEC HD 629.1, CENELEC EN 50180, IEC 60137, IEC 60502-4 or country speci-fications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are con-tinuously performed in our test fields.
Nexans Network SolutionsDiv. Euromold
COMPANY PRESENTATION
-
302/2
011
SEPARABLE CONNECTORSAND BUSHINGS
INTERFACE B
Table of contents400LR - elbow connector400TE - tee connector400T1 - equipment bushing400AR-1 - equipment bushing400AR-2 - equipment bushing400AR-8 - equipment bushing400SFR-P - equipment bushingAccessoriesPossible arrangements
Interface BDimensions according to European CENELEC EN 50180 and 50181 (in mm).
900.2
Dia. 460.2
Dia. 560.2
Dia. 700.2
40min
Dia. forpin 14 0 -0.04
11min
-
4 02/20
11
Connecting possibilities
BUSHINGS / ACCESSORIES
CONNECTION CONNECTORS / ACCESSORIES
(K)(M)400DR Dead-end receptacle
(K)(M)400TE/GTee connector
(K)(M)400SOPStand-off plug
400GPEarthing plug
dead-ending of equipment
one cable toequipment
cableisolation
cableearthing
(K)400RTPAReducing tap plug
(K)(M)400CP-SC Connecting plug
two cables to equipment
tap-off630/250A
in-line junction
(K)(M)400LR/GElbow connector
(K)400SFR-PEquipment bushing
(K)(M)400AR-8Equipment bushing
Equipmentinterface
(K)(M)400AR-1Equipment bushing
(K)(M)400T1Equipment bushing
(K)(M)400AR-2Equipment bushing
-
502/2
011
Specifications and standardsThe separable connector 400LR meets the requirements of CENELEC HD 629.1.
Up to 36 kV - 400 A
DesignSeparable connector comprising:1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer moulded between the insert and the jacket.4. Type B - 400 A interface as described by CENELEC EN 50180 and 50181.5. Conductor connector.6. Cable reducer.7. Earthing lead.
The screen break design enables cable outer sheath testing without removing or dismantling the connector.
400LRINTERFACE B
ELBOW CONNECTOR
ApplicationSeparable elbow connector (plug-in type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...).
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
18/30 (36) kV
Technical characteristics ThethickconductiveEPDM
jacket provides a total safe to touch screen which ensures safety for personnel.
Eachseparableconnectoristested for AC withstand and partial discharge prior to leaving the factory.
210 mm
365 mm
4
5
1
2
3
7
6
Separable connector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor sizes (mm2)
min max400LR/G
K400LR/G
M400LR/G
12
24
36
400
400
400
50
25
35
240
240
185
-
6
Kit contentsThe complete (K)(M)400LR/G elbow connector kit comprises the following components:
The kit also comprises lubricant, wipers,
installation instructions and crimp chart.
Ordering instructionsSelect the part numberwhich gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type.Add a 'K' for use up to 24 kV and add an 'M' for use up to 36 kV.
Conductor
contact
400LRC-X
Pin contact
+ hex. key
400LRF
Bail
restraint
400BA
Connector housing
(K)(M)400BLR/G
Cable reducer
411CA-W
Orderingpart number
Dia. over core insulation (mm)
min max
400LR/G-11-X400LR/G-15-X400LR/G-19-X400LR/G-22-X400LR/G-25-X400LR/G-27-X
12.0
16.0
20.0
23.5
26.5
28.5
17.5
22.0
26.5
31.0
32.5
37.5
Example:The copper wire screened cable is 12 kV, 150 mm2 stranded copper with a diameter over core insulation of 23.5 mm.Order a 400LR/G-19-150(K)M-11-2 elbow connector kit.
(K)(M)400LR/G-W-Xconnector kit
Table X
Table W
Conductorsizes
(mm)
Aluminium Copper
DIN hexagonal Deep indent DIN hexagonal
25
35
50
70
95
120
150
185
240
-
35(K)M-12-2
50(K)M-12-2
70(K)M-12-2
95(K)M-12-2
120(K)M-12-2
150(K)M-12-2
185(K)M-12-2
240(K)M-12-2
-
35KM-12-1
50(K)M-12-1
70(K)M-12-1
95(K)M-12-1
120(K)M-12-1
150(K)M-12-1
185(K)M-12-1
240(K)M-12-1
25(K)M-11-2
35(K)M-11-2
50(K)M-11-2
70(K)M-11-2
95(K)M-11-2
120(K)M-11-2
150(K)M-11-2
185(K)M-11-2
240(K)M-11-2
For applicationsoutdoors and in humid climate.
Order: +MWS.
Components can be ordered individually.
For use withcopper tape
screened cables. Order: Kit MT.
For use with Alupe orC 33-226 cables.
Please contact our representative.
For use with fabric tape (graphite) screened cables.
Order additionalsemi-conductive tape
(type TSC).
For use withother cable types.
Please contact our representative.
-
702/2
011
Specifications and standardsThe separable connector 400TEmeets the requirements of CENELEC HD 629.1.
Up to 36 kV - 400 A
400TEINTERFACE B
TEE CONNECTOR
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
18/30 (36) kV
ApplicationSeparable tee connector (plug-in type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...).
Technical characteristics ThethickconductiveEPDM
jacket provides a total safe to touch screen which ensures safety for personnel.
Eachseparableconnectoristested for AC withstand and partial discharge prior to leaving the factory.
Separable connector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor sizes (mm2)
min max400TE/G
K400TE/G
M400TE/G
12
24
36
400
400
400
70
25
35
240
240
185
255 mm
220 mm
390 mm
4 9
5
1
3
2
10 6 8
7
11
DesignSeparable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type B - 400 A interface as described by CENELEC EN 50180 and 50181. 5. Conductor connector. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping pin contact. 10. Bail restraint. 11. Earthing lead.
The screen break design enables cable outer sheath testing without removing or dismantling the connector.
-
8
The kit also comprises lubricant, wipers,
installation instructions and crimp chart.
Kit contentsThe complete (K)(M)400TE/G elbow connector kit comprises the following components:
Ordering instructionsSelect the part numberwhich gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type.Add a 'K' for use up to 24 kV and add an 'M' for use up to 36 kV.
Orderingpart number
Dia. over core insulation (mm)
min max
400TE/G-11-X400TE/G-15-X400TE/G-19-X400TE/G-22-X400TE/G-25-X400TE/G-27-X
12.0
16.0
20.0
23.5
26.5
28.5
17.5
22.0
26.5
31.0
32.5
37.5
(K)(M)400TE/G-W-Xconnector kit
Conductor
contact
400TEC-X
Clamping
pin contact
400TEF
Bail
restraint
400T-BA
Connector housing (K)
(M)400BT/G
Basic
insulating
plug +
rubber cap
(K)(M)400BIPA
Cable reducer
411CA-W
Example:The copper wire screened cable is 24 kV, 240 mm2 stranded aluminium with a diameter over core insulation of 32.1 mm.Order 3 x K400TE/G-27-240(K)M-12-2 tee connector kit.
Conductorsizes
(mm)
Aluminium Copper
DIN hexagonal Deep indent DIN hexagonal
25
35
50
70
95
120
150
185
240
-
35(K)M-12-2
50(K)M-12-2
70(K)M-12-2
95(K)M-12-2
120(K)M-12-2
150(K)M-12-2
185(K)M-12-2
240(K)M-12-2
-
35KM-12-1
50(K)M-12-1
70(K)M-12-1
95(K)M-12-1
120(K)M-12-1
150(K)M-12-1
185(K)M-12-1
240(K)M-12-1
25(K)M-11-2
35(K)M-11-2
50(K)M-11-2
70(K)M-11-2
95(K)M-11-2
120(K)M-11-2
150(K)M-11-2
185(K)M-11-2
240(K)M-11-2
Table X
Table W
For applicationsoutdoors and in humid climate.
Order: +MWS.
Components can be ordered individually.
For use withcopper tape
screened cables. Order: Kit MT.
For use with Alupe orC 33-226 cables.
Please contact our representative.
For use with fabric tape (graphite) screened cables.
Order additionalsemi-conductive tape
(type TSC).
For use withother cable types.
Please contact our representative.
-
902/2
011
Up to 36 kV - 400 A
Equipmentbushing
type
VoltageUr
(kV)
CurrentIr
(A)
Dimensions (mm)
A B C D E Dia. F Dia. G Dia. H
400T1K400T1M400T1400AR-1
K400AR-1M400AR-1400AR-2
K400AR-2M400AR-2
122436122436122436
400400400400400400400400400
310310310380380380329329329
144144144213213213138138138
303030303030363636
M12M12M12M12M12M12M16M16M16
222222222222404040
888888747474100100100
128128128128128128150150150
161616161616303030
400T1 /400AR-1 /400AR-2INTERFACE B
EQUIPMENT BUSHINGS
ApplicationFor use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors...
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
18/30 (36) kV
Technical characteristics Each bushing is tested forAC withstand and partialdischarge prior to leaving thefactory.
Ordering instructionsTo order the equipment bushing, specify the type.The bushings are supplied with an earth jumper (/J) or an earth plate (/GS). This earth connection must be specified when ordering.E.g. K400AR-1/J.
Specifications and standardsThe plug-in type equipment bushings are moulded epoxy insulated parts and meet the requirements of IEC 60137. The (K)(M)400T1 also meets CENELEC EN 50180 .
In mm
Minimum oil level:-12 kV: 40 mm-24 kV: 50 mm-36 kV: 70 mm
E
Dia. G
133
B
A
Dia. F
Dia. 70D
10
C
Dia.H
-
10
FIXINGS FOR EQUIPMENT BUSHINGS
In mm
400AR-1/J and 400T1/J Bushings
400AR-2/GS Bushing
Bushing clamping kitTo order the bushing clamping kit, according to NFC 52-053 standards, simply specify KBCNF-400 (for bushing type 400AR-2).Contents: - 4 x claw clamp NF - 1 x sealing gasket.
Fixing dimensions standards NF C 52-053French standards.
Fixing dimensions standards DIN 42 538German standards.
Dia. 105Dia. 171
6030
6 fixingstuds
M10M10 or M12
Dia. 105Dia. 171
50 to 7025
4 fixingstuds
55
Dia. 140Dia. 90
30
M10
6 fixingstuds
Fixing dimensions
Bushing clamping kitTo order the bushing clamping kit, simply specify: KBCDS-400B. Contents: - 1 x fixing flange - 6 x stud clamp F - 1 x sealing gasket.
400AR-2/J Bushing
bushing interface
fixing studs
equipmentconnection
sealing gasket
earthjumper
F DIN 42 538stud clamp
fixing flange
NF C 52-053claw clamp
equipment
earthplate
tabs for thebail restraint
fixing flangeB DIN 42 538
E DIN 42 538stud clamp
bushinginterface
fixing studs
equipment
sealing gasket
equipmentconnection
tabs for thebail restraint
earthjumper
Bushing clamping kitTo order the bushing clamping kit, according to DIN 42 538 standards, simply specify KBCD-400B.Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket.
-
11
02/2
011
Equipmentbushing
type
VoltageUr
(kV)
CurrentIr
(A)
400AR-8
K400AR-8
M400AR-8
12
24
36
250
250
250
Up to 36 kV - 250 A
400AR-8INTERFACE B
EQUIPMENT BUSHING
ApplicationFor use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors...
Technical characteristics Each bushing is tested forAC withstand and partial discharge prior to leavingthe factory.
Ordering instructionsTo order the equipment bushing, specify the type.The bushings can be supplied with an earth jumper (/J).E.g. M400AR-8/J.
In mm.
6/10 (12) kV6,35/11 (12) kV8,7/15 (17,5) kV
12/20 (24) kV12,7/22 (24) kV
18/30 (36) kV
80
231.528
Dia. 74
Dia. 110
20
Minimum oil level:-12 kV: 40 mm-24 kV: 50 mm-36 kV: 70 mm
M10
8.5Dia.20
Specifications and standardsThe plug-in type equipment bushings 400AR-8 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 60137.
-
12
In mm.
FIXINGS FOR EQUIPMENT BUSHINGS
400AR-8/J Bushing
55
M10
Dia. 78
Dia. 123
25
4 fixingstuds
Fixing dimensions standards DIN 42 538German standards.
Bushing clamping kitTo order the bushing clamp-ing kit, according to DIN 42 538 standards, simply specify: KBCD-200.Contents: - 1 x fixing flange A - 4 x stud clamp E - 1 x sealing gasket.
4 x fixing stud M10
A DIN 42 538fixing flange
E DIN 42 538stud clamp
equipment
tabs for thebail restraint
bushing interface
sealing gasket
equipmentconnection
earth jumper
-
13
02/2
011
Up to 24 kV - 400 A
400SFR-PINTERFACE B
EQUIPMENT BUSHING
ApplicationFor use in equipment insulated with SF6 gas.
6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
DesignThe equipment bushing is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN 50180. The 400SFR-P bushing has a shank outside this standard, adapted for use in SF6 gas.
Technical characteristics Each bushing is tested forAC withstand and partialdischarge prior to leaving thefactory.
Ordering instructionsTo order the equipment bushing, simply specify the type.
Specifications and standardsThe plug-in type equipment bushing 400SFR-P meets the requirements of CENELEC EN 50180 and IEC 60137.
Equipmentbushing
type
VoltageUr
(kV)
CurrentIr
(A)
400SFR-P
K400SFR-P
12
24
400
400
Dia. 70
95
33
218
Dia. 109
Dia. 25
Dia. 70
M12
In mm.
-
14
FIXINGS FOR EQUIPMENT BUSHINGS
400SFR-P Bushing for gas insulated switchgear
In mm.
MOUNTED
equipment
sealingO-ringgasket
equipmentconnection
bushinginterface 6 fixing
screwsM6
UNMOUNTED
earthconnection
M4
60
6060
Dia. 91.5Dia. 103.1
83
M6
M4
-
15
02/2
011
ACCESSORIESINTERFACE B
Up to 24 kVApplicationFor use with connectors and bushings with an interface B as described by CENELEC EN 50180 and 50181.
Technical characteristics All these products, except theearthing plug, are tested forAC withstand and partialdischarge prior to leaving thefactory. 6/10 (12) kV
6.35/11 (12) kV8.7/15 (17.5) kV
12/20 (24) kV12.7/22 (24) kV
18/30 (36) kV
400DRDead-end receptacleFits over a bushing with a type B interface to provide 'dead-end' facility.Is used with a 400BA restraint bail.
Ordering instructionsOrder400DR for 12 kV,K400DR for 24 kV orM400DR for 36 kVapplications.Can be supplied with integral earth lead: add -/G.
400GPEarthing plugIs designed to support and earth connectors with a type B interface when removed from equipment.
Ordering instructionsOrder 400SOP for 12 kV,K400SOP for 24 kV orM400SOP for 36 kVapplications.
Ordering instructionsOrder 400GP for 12 kV, 24 or 36 kVapplications.
400SOPStand-off plugIs designed to support and 'dead-end' connectors with a type B interface when removed from equipment.
-
16
400CP-SCConnecting plugFor connecting a 400TE and one or more 430TB, 400TB or 440TB connectors, thus creating a multiple cable connection to equipment.
Ordering instructionsOrder 400CP-SC for 12 kV,K400CP-SC for 24 kV orM400CP-SC for 36 kVapplications.
400RTPAReducing tap plugProvides a type A interface to a 400TE connector.A 'C' spanner, 600SW, is used to tighten the reducing tap plug on to its mating part.
Ordering instructionsOrder 400RTPA for 12 kV orK400RTPA for 24 kVapplications.Order 600SW for the 'C'spanner.
Kit MTEarthing kit for copper tape screened cablesContains a tinned copper braid (25 mm - L=500 mm), a tinned copper wire for cleating and water sealing mastic.
Ordering instructionsOrder Kit MT for 12 kV, 24 kV or 36 kV applications.
400BIPABasic insulating plugActs as a tightening nut for the 400TE tee connector kit.The plug contains a voltage detection point.The conductive rubber protection cap is included.
Ordering instructionsOrder 400BIPA for 12 kV,K400BIPA for 24 kV orM400BIPA for 36 kVapplications.
-
17
02/2
011
POSSIBLE ARRANGEMENTSINTERFACE B
400TE/GSingle cable arrangement.Order 400TE/G for 12 kV,K400TE/G for 24 kV or M400TE/G for 36 kV applications.
400TE/G-P2Dual cable arrangement.Order 400TE/G-P2 for 12 kV, K400TE/G-P2 for 24 kV or M400TE/G-P2 for 36 kV applications.
400TE/G-P4Single cable arrangement with tap-off.Order 400TE/G-P4 for 12 kVor K400TE/G-P4 for 24 kV applications.
250
110
basic insulating
plug
500
110 245
basic insulating
plug
400TCS clamping
screw
connecting plug
475
110 233
reducing tap plug
type A separable connector
In mm
-
18
basic insulating
plug
stand-off plug
basic insulating
plug
earthing plug
Connector on earthing plugOrder 400GP for 12 kV, 24 kV and 36 kV applications.
Connector on stand-off plugOrder 400SOP for 12 kV, K400SOP for 24 kV or M400SOP for 36 kV applications.
In mm
110
600
400TR test rod
insulating shroud
Cable and equipment testing
-
Additional catalogue information on power cable accessoriesis available by contacting us at the address below:
NexansNetworkSolutionsN.V.-Div.EuromoldZuidIII,Industrielaan12,B-9320ErembodegemTel.:+32(0)53850211Fax:+32(0)[email protected]
Catalogue also available on CD-ROM
Distributed by: