Download - LFV300 Universal Limit Switch for Liquids
TThe level sensors of the LFV300 series are
universally usable limit switches that detect
predefined filling heights in liquid systems
with millimetre-accuracy – even under diffi-
cult operating conditions. The measurement
principle of the oscillating fork reacts to
changes in density between the surrounding
air and the liquid, and thus operates inde-
pendently of the tank material, container
structures or the liquid involved. The rugged
sensor requires no calibration with the me-
dium and operates without wear or mainte-
nance.
Area of use
There are almost no restrictions to the
device’s areas of use as a limit switch in
tanks, storage and intermediate containers,
or to protect pumps from dry-running – thanks
to the universal measurement principle of
the LFV300 and its flexible design. A tube-ex-
tended variant for vertical mounting with up
to 6 metres switching distance to the top of
the container is also available – the LFV330.
A wide selection of flange, threads and hygi-
enic connections allow customer-specific so-
lutions. The device is suitable for hygienic ap-
plications and can be cleaned using SIP and
CIP processes. There are also variants for
use in potentially explosive atmospheres, to
prevent overfilling (in compliance with WHG),
and with marine certification.
Advantages:
� Rugged device design
� Flexible concept allows customer-
specific solutions, particularly in
hygienic areas and Ex-zones
� Teaching without filling
� Very high reproducibility
Level switch for full and empty messages
Vibronic level switch
The LFV300 universal limit switch for liquids – rugged and reliable measurement of liquids using the tuning fork principle
Da
ta
sh
ee
t
2 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.
LFV300
Fault monitoringThe electronics module of LFV300 monitors continuouslythe following criteria:
� Strong corrosion or damage on the tuning fork
� Loss of vibration
� Line break to the piezo drive
Type overview
LFV310 LFV330
Attributes
Preferred application: Liquids Liquids
Length: - 80… 6000 mm (3.15… 236.22 in)tube extention
Process connection: Thread G¾ A, G1 A, flanges, hygienicfittings
Thread G¾ A, G1 A, flanges, hygienicfittings
Process temperature: -50… +150°C (-58… +302 °F)-50… +250°C (-58… +482 °F) with temperature adapter
-50… +150°C (-58… +302 °F)-50… +250°C (-58… +482 °F) withtemperature adapter
Process pressure: -1 … 64 bar (-14.5… 928 psi) -1 … 64 bar (-14.5… 928 psi)
Signal output: Relay, transistor, NAMUR output, contactless electronic switch
Relay, transistor, NAMUR output, contactless electronic switch
Housing types
1 Plastic housing2 Aluminium housing3 Stainless steel
1 2 3
8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 3 Subject to change without notice.
LFV300LFV300
Technical data
Electric data Process pressure –1 … 64 bar Process temperature -50 ... 150°C (optional 250°C) Fill material density > 0,5 ... 2.5g/cm3
Viscosity 0.1 … 10000 mPas Materials, non-wetted parts 1.4404 (Optional Ra < 0,8 μm) Material, housing Aluminium, plastic, stainless steel Response time 500 msProcess connection G ¾”, G1”, flange, triclamp, pipe connection DIN 11851 (further see type code)Accuracy ± 2 mmReproducibility ± 1 mmHysteresis switching output 2 mmTemperature drift 0,03 mm/KAmbient temperature operation –40 … +70 °CAmbient temperature storage –40 … +80 °CEnclosure rating IP 66/ 67 or IP 66/IP68 (0.2bar)Length (only for LFV330) 80mm ... 6.000mm tube extension
Electronic (Version T) Electronic (Version C)Switching output Transistor output Contactless electronic switchSignal voltage HIGH UV – 3 VSignal voltage LOW < 1VOutput current IA < 300 mA < 400 mAOutput loadCapacitive load 100 nF 100 nFInductive load 1 H 1 HSupply voltage 10 … 55 VDC 20 ... 253V AC/DCResidual ripple ≤ 5 VPP
Current consumption < 10 mA < 4.2 mAInitialization time < 2 s < 3 sProtection class
Electronic (Version R) Electronic (Version N)Switching output Relay output Namur output Output current IA >10uA; <3A AC, 1A DC 1mA / 2,5mA Output load Capacitive load 750VA 54WInductive load 750VA 54WSupply voltage 20 ... 253VAC; 20 ... 72 V DC 4,5 ... 12 V DCCurrent consumption 5 ... 30mA 1mA / 2,5mA Initialization time < 2 s < 2 sProtection class
Approvals Overfill protection according to WHGATEX ATEX II 1G, 1/2G, 2G Ex ia IIC T6 ATEX II 1/2G, 2G Ex d IIC T6Marine certification GL
EHEDG-certificationFDA-conformity
Dimensions
LFV310
G¾A, ¾"NPTG1A, 1"NPT
18,5
32 (G¾A, ¾"NPT)41 (G1A, 1"NPT)
57
50
ø 33,7
3619
5353
53
55G¾
=66
G1=
69
�
� �
� �
4 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.
Electrical Connection
1. Preparing the connectionNote safety instructions Always keep in mind the following safety instructions:
� Connect only in the complete absence of line voltageTake note of safety instructions for Ex applications
In hazardous areas you should take note of the appropriate regulations, conformity and type approval certificates of the sensors and power supply units.
In hazardous areas, only use approved cable connections for LVF310/330.
Select connection cable for Ex applications Take note of the corresponding installation regulations for Ex applications.
1 Thread2 Tri-Clamp3 Cone DN 254 Bolting DN 405 FlangeL Sensor length, see chapter „Technical data“
LFV300
Temperature adapter - LFV310/330
1 Thread2 Tri-Clamp3 Cone DN 254 Bolting DN 405 Flange
LFV330
G 3/4 A, 3/4" NPTG 1 A, 1" NPT
L
L
LL
L
32 (G
3/ 4
A, 3
/ 4" N
PT)
41 (G
1 A
, 1" N
PT)
�
� �
� �
18.5
57
50
ø 33,7
3619
8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 5 Subject to change without notice.
2. Wiring plan
Relay output
We recommend connecting LFV300 in such a way that the switching circuit is open when there is a level signal, line break or failure (safe condition).
The relays are always shown in non-operative condition.
LFV300 - oscillator with relay output
1 Control lamp2 DIL switch for mode adjustment3 DIL switch for sensitivity adjustment
LFV300 - wiring plan - relay output
1 Relay output2 Relay output3 Voltage supply
Transistor output
We recommend connecting LFV300 in such a way that the switching circuit is open when there is a level signal, line break or failure (safe condition).
The instrument is used to control relays, contactors, magnetvalves, warning lights, horns as well as PLC inputs.
LFV300 - oscillator with transistor output
1 Control lamp2 DIL switch for mode adjustment3 DIL switch for sensitivity adjustment
LFV300 transistor output - NPN action
LFV300 transistor output - PNP action
LFV300LFV300
6 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.
Contactless electronic switch
We recommend connecting LFV300 in such a way that the switching circuit is open when there is a level signal, line break or failure (safe condition).
The contactless electronic switch is always shown in non-operative condition.
The instrument is used for direct control of relays, contactors,magnet valves, warning lights, horns etc. It must not be operated without an intermediately connected load, because the electronics would be destroyed if connected directly to the mains. It is not suitable for connection to low voltage PLC inputs.Domestic current is temporarily lowered below 1mA after switching off the load so that contactors, whose holding current is lower than the constant domestic current of the electronics, are reliably switched off.
When LFV300 is used as part of an overfill protection system according to WHG, also note the regulations of the general type approval.
LFV300 - oscillator with contactless electronic switch
1 Control lamp2 DIL switch for mode adjustment3 DIL switch for sensitivity adjustment
LFV300 - wiring plan - output, contactless electronic switch
NAMUR output
LFV300 - oscillator with NAMUR electronics
1 Control lamp2 DIL switch for characteristics reversal3 DIL switch for sensitivity adjustment4 Simulation keyFor connection of the amplifier according to NAMUR(IEC 60947-5-6, EN 50227).
LFV300 - Wiring plan - NAMUR output
Simulation keyThe simulation key is located in a recess on the upper side of the oscillator. Push the simulation key with a suitable object (screwdriver, pen, etc.).When the key is pushed, a line break between sensor and processing unit is simulated. The signal lamp on the sensor extinguishes. The measuring system must signal a fault and take on a safe condition when the key is pushed.Keep in mind that downstream connected instruments will be activated during operation. This allows you to check the correct function of the measuring system.
Characteristics reversalThe characteristics of the NAMUR electronics can be reversed with the DIL switch. You can choose between falling characteristic curve (switch position max.) and rising characteristic curve (switch position min.). You can thus have the desired current outputted.Modes:
�min. - rising characteristic curve (High current when immersed) �max. - falling characteristics (Low current when immersed)
The NAMUR-output can be switched to falling or rising characteristics.For applications according to WHG, the DIL switch must be set toposition max..
LFV300
NAMUR-amplifier
8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 7 Subject to change without notice.
Mounting instructions
Switching pointIn general, LFV300 can be installed in any position. The instrument simply has be mounted in such a way that the vibrating element is at the height of the desired switching point.
The tuning fork has lateral markings (notches) marking the switching point with vertical installation. The switching point refers to the medium water with basic setting of the density switch ≥ 0.7g/cm³ (0.025 lbs/in³).
Keep in mind that foams with a density > 0.45 g/cm³ (0.016 lbs/in³) are detected by the sensor.
SocketThe vibrating element should protrude into the vessel to avoid build-up. For that reason, avoid using mounting bosses for flanges and screwed fittings. This applies particularly for horizontal installation and with adhesive products.
AgitatorsDue to agitators, vibrations or similar, the level switch can be subjected to strong lateral forces. For this reason, do not use an overly long extension tube for LFV330, but check if you can mount a LFV200 or LFV310 level switch on the side of the vessel in horizontal position.
Extreme vibration caused by the process or the equipment, e.g.agitators or turbulence in the vessel, can cause the extension tube of LFV300 to vibrate in resonance. This leads to increasedstress on the upper weld joint. Should a longer tube version be necessary, you can provide a suitable support or guy directly above the vibrating element to secure the extension tube.
This measure applies particularly to applications in Ex areas. Make sure that the tube is not subjected to bending forces through this measure.
Inflowing mediumIf LFV300 is mounted in the filling stream, unwanted mismeasurements may result. Mount LFV300 at a location in the vessel where no disturbing influence from e.g. filling openings, agitators, etc. can occur.
FlowsTo minimise flow resistance caused by the tuning fork, LFV300 should be mounted in such a way that the surfaces of the blades are parallel to the product movement.
LFV300LFV300
8 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.
Deviation ±1 mm (0.04 in)
Influence of the process temperature on the switching point
1 Shifting of the switching point in mm (in)2 Process temperature in °C (°F)3 Switching point at reference conditions (notch)4 Tuning fork
Influence of the product density on the switching point
1 Shifting of the switching point in mm (in)2 Product density in g/cm³ (lb/in³)3 Switch position 0.5 g/cm³ (0.018 lb/in³)4 Switch position 0.7 g/cm³ (0.025 lb/in³)5 Switching point at reference conditions (notch)6 Tuning fork
Measuring accuracy
LFV300
8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 9 Subject to change without notice.
Influence of the process pressure to the switching point
1 Shifting of the switching point in mm (in)2 Process pressure in bar (psi)3 Switching point at reference conditions (notch)4 Tuning fork
Ambient temperature - Product temperature
1 Product temperature2 Ambient temperature3 Temperature range with temperature adapter
Repeatability 0.1 mm (0.004 in)Hysteresis approx. 2 mm (0.08 in) with vertical installationSwitching delay approx. 500 ms (on/off)Frequency approx. 1200 Hz
LFV300LFV300
1 0 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.
LFV300
LFV310 –
Approvalwithout approvalOverfill protection acc. to WHGATEX II 1G, 1/2G, 2G Ex ia IIC T6 + WHGATEX II 1/2G, 2G Ex d IIC T6 + WHGATEX II 1G, 1/2G, 2G Ex ia IIC T6 + marine certificationATEX II 1/2G, 2G Ex d IIC T6 + marine certification Marine certification GL
Process fitting / MaterialThread G¾ A PN64 / 316LThread ¾ NPT PN64 / 316LThread G1 A PN64 / 316LThread 1 NPT PN64 / 316LTri-Clamp 1“ PN16 / 316L Ra<0.8µmTri-Clamp 2“ PN16 / 316L Ra<0.8µmTri-Clamp 3“ PN16 / 316L Ra<0.8µmBolting DN40 PN40 DIN11851 / 316L Ra<0,8µmVarivent N50-40 / 316L Ra<0,8µmDRD-Flange PN40/316L ZB3007Flange DN25 PN40 Form C, DIN 2501 / 316LFlange DN50 PN40 Form C, DIN 2501 / 316LFlange DN40 PN40 Form C,DIN 2501/ 316LFlange DN80 PN40 Form C,DIN 2501/ 316LFlange 1“ 150lb RF, ANSI B16.5 / 316LFlange 2“ 150lb RF, ANSI B16.5 / 316Lothers on request
Adapter / Process temperaturewithout / -50...150°Cwith / -50...250°C
HousingPlastic IP 66/ 67 / M20x1.5Plastic IP 66/ 67 / ½“ NPTPlastic IP 66/ 67 / Plug M12x1 (4-pin) Plastic IP 66/ 67 / Plug M12x1 (5-pin)Plastic IP 66/ 67 / Plug M12x1(5-pin; EN50044) Plastic IP 66/ 67 / Plug M12x1(4-pin; EN50044) Aluminium IP 66/IP67 / M20x1.5Aluminium IP 66/IP67 / ½“ NPT Aluminium IP 66/ 67 / Plug M12x1 (4-pin)StSt (electropolished) 316L / IP 66/IP67 / M20x1.5StSt (electropolished) 316L / IP 66/IP67 / ½“ NPT ElectronicsContactless electronic switch 20...250 V AC/DCDouble relay (DPDT) 20...72 V DC/20...250 V AC (3A)Transistor (NPN/PNP) 10...55 V DCNAMUR signalSwitching pointStandardSwitching point prolongued 118 mm
XT
CRTN
XL
XXCDCDX
XAAAMMM
GNGNCCCR
BBAACAEA
VVVVPPPP
TDFFFFAA
AAPECIPC
PVVVVVVV
Type code
P
WYDMUZ89
NT
Order Information
Housing Process conection Electronics Model name Part no.
Plastic IP 66/ 67/ M20x1,5
Thread G ¾ A PN64
Contactless switch 20...250 V AC/DCLFV310-XXGBVTPCX 6037999
LFV310-XXGBVXPCX 6037990
Relay (DPDT) 20...72 V DC/20...250 V AC (3A)
LFV310-XXGBVTPRX 6038002
LFV310-XXGBVXPRX 6037993
Transistor (NPN/PNP) 10...55 V DCLFV310-XXGBVTPTX 6037996
LFV310-XXGBVXPTX 6037888
Thread ¾“ NPT PN64Relay (DPDT) 20...72 V DC/
20...250 V AC (3A)LFV310-XXNBVXPRX 6038972
Aluminium IP 66/IP67/ M20x1,5
Thread G ¾ A PN64
Contactless switch 20...250 V AC/DCLFV310-XXGBVXMCX 6037989
LFV310-XXGBVTMCX 6037998
Relay (DPDT) 20...72 V DC/20...250 V AC (3A)
LFV310-XXGBVXMRX 6037991
LFV310-XXGBVTMRX 6038000
Transistor (NPN/PNP) 10...55 V DCLFV310-XXGBVXMTX 6037751
LFV310-XXGBVTMTX 6037994
Thread G 1 A PN64Relay (DPDT) 20...72 V DC/
20...250 V AC (3A)LFV310-XXGAVXMRX 6039134
StSt (electropolished)316L / IP 66/IP67/
M20x1,5Thread G ¾ A PN64
Contactless switch 20...250 V AC/DCLFV310-XXGBVX8CX 6037916
LFV310-XXGBVT8CX 6037997
Relay (DPDT) 20...72 V DC/20...250 V AC (3A)
LFV310-XXGBVT8RX 6038001
LFV310-XXGBVX8RX 6037992
Transistor (NPN/PNP) 10...55 V DC
LFV310-XXGBVT8TX 6037995
LFV310-XXGBVX8TX 6037752
Plastic IP 66/ 67/ Plug M12x1 (4-pin) Thread G 1 A PN64 LFV310-XXGAVXTTX 6039737
Plastic IP 66/ 67/ Plug M12x1 (5-pin) Thread G ¾ A PN64 LFV310-XXGBVXWTX 6039061
The displayed part numbers are only an extract of the possible variations. You find further part numbers on www.mysick.com or contact your SICK-sales person.
8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 1 1 Subject to change without notice.
LFV300LFV300
1 2 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.
LFV300
Type code
P
WYDMUZ89
NT
LFV330 –
Approvalwithout approvalOverfill protection acc. to WHGATEX II 1G, 1/2G, 2G Ex ia IIC T6 + WHGATEX II 1/2G, 2G Ex d IIC T6 + WHGATEX II 1G, 1/2G, 2G Ex ia IIC T6 + marine certificationATEX II 1/2G, 2G Ex d IIC T6 + marine certification Marine certification GL
Process fitting / MaterialThread G¾ A PN64 / 316LThread ¾ NPT PN64 / 316LThread G1 A PN64 / 316LThread 1 NPT PN64 / 316LTri-Clamp 1“ PN16 / 316L Ra<0.8µmTri-Clamp 2“ PN16 / 316L Ra<0.8µmTri-Clamp 3“ PN16 / 316L Ra<0.8µmPipe connection DN40PN40 DIN11851 / 316L Ra<0,8µmVarivent N50-40 / 316L Ra<0,8µmDRD-Flange PN40/316L ZB3007Flange DN25PN40 Form C, DIN 2501 / 316LFlange DN50PN40 Form C, DIN 2501 / 316LFlange DN40PN40 Form C,DIN 2501/316LFlange DN80PN40 Form C,DIN 2501/316LFlange 1“ 150lb RF, ANSI B16.5 / 316LFlange 2“ 150lb RF, ANSI B16.5 / 316Lothers on request
Adapter / Process temperaturewithout / -50...150°Cwith / -50...250°C
HousingPlastic IP 66/ 67 / M20x1.5Plastic IP 66/ 67 / ½NPTPlastic IP 66/ 67 / Plug M12x1 (4-pin) Plastic IP 66/ 67 / Plug M12x1 (5-pin)Plastic IP 66/ 67 / Plug M12x1(5-pin; EN50044) Plastic IP 66/ 67 / Plug M12x1(4-pin; EN50044) Aluminium IP 66/IP67 / M20x1.5Aluminium IP 66/IP67 / ½ NPT Aluminium IP 66/ 67 / Plug M12x1 (4-pin)StSt (electropolished) 316L / IP 66/IP67 / M20x1.5StSt (electropolished) 316L / IP 66/IP67 / ½NPTElectronicsContactless electronic switch 20...250 V AC/DCDouble relay (DPDT) 20...72 V DC/20...250 V AC (3A)Transistor (NPN/PNP) 10...55 V DCNAMUR signalLength min. 80mm max. 6000mm
XXCDCDX
XAAAMMM
XT
CRTN
X
0 0 0 0
GNGNCCCR
BBAACAEA
VVVVPPPP
TDFFFFAA
AAPECIPC
PVVVVVVV
Housing Process conection Electronics Model name Part no.
Plastic IP 66/ 67 (M20x1,5)
Thread G ¾ A PN64
Contactless switch 20...250 V AC/DC LFV330-CMGBVXPCX0160 6040971
Namur LFV330-CMGBVXPNX0160 6039512
Relay (DPDT)
LFV330-XXGBVXPRX0300 6039663
LFV330-XXGBVXPRX0500 6039661
LFV330-XXNBVXPRX0100 6038973
Thread ¾“ NPT PN64Contactless switch 20...250 V AC/DC
LFV330-DMGBVXMCX0160 6040973
Aluminium IP 66/IP67 (M20x1,5)
Thread G ¾ A PN64
LFV330-DAGBVXMCX0500 6039736
Namur LFV330-DMGBVXMNX0160 6040972
Relay (DPDT) 20...72 V DC/20...250 V AC (3A)
LFV330-XXGBVXMRX0200 6039665
LFV330-DAGBVXMRX0300 6041182
LFV330-XXGBVXMRX1200 6041285
LFV330-DAGBVXMRX3000 6039761
Transistor (NPN/PNP) 10...55 V DC
LFV330-XXGBVXMTX0100 6039668
LFV330-XXGBVXMTX0100 6039668
Thread ¾“ NPT PN64 LFV330-XXNBVXMTX0500 6039667
Thread G 1 A PN64
Relay (DPDT) 20...72 V DC/20...250 V AC (3A)
LFV330-XXGAVXMRX1300 6039693
LFV330-XXGAVXMRX1600 6039692
LFV330-XXGAVXMRX2000 6039691
LFV330-XXGAVXMRX0900 6039694
Transistor (NPN/PNP) 10...55 V DC LFV330-XXGAVXMTX0300 6039666
Relay (DPDT) 20...72 V DC/20...250 V AC (3A)
LFV330-XXGBVX8RX0300 6039664
StSt (electropolished) 316L / IP 66/IP67
(M20x1,5)Thread G ¾ A PN64
LFV330-XXGBVX8RX0500 6039662
Transistor (NPN/PNP) 10...55 V DC
LFV330-XXGBVX8TX0150 6041341
LFV330-XXGBVX8TX0100 6039669
LFV330-XXNBVX8TX0200 6039670
The displayed part numbers are only an extract of the possible variations. You find further part numbers on www.mysick.com or contact your SICK-sales person.
Order Information
8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 1 3 Subject to change without notice.
LFV300LFV300
1 4 S I C K 8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 Subject to change without notice.
Accessoriers
LFV300
Plug connector, M8, 4-pin, straight
Connector type Sheath material Cable length Model name Part no.
Connector M8, Enclosure rating IP 67
PVC2 m DOL-0804-G02M 6009870
5 m DOL-0804-G05M 6009872
PUR halogenfree
2 m DOL-0804-G02MC 6025894
5 m DOL-0804-G05MC 6025895
Plug connector, M12, 4-pin, straight
Connector type Sheath material Cable length Model name Part no.
Connector M12,Enclosure rating IP 67
PVC2 m DOL-1204-G02M 6009328
5 m DOL-1204-G05M 6009866
PUR halogenfree
2 m DOL-1204-G02MC 6025900
5 m DOL-1204-G05MC 6025901
Food & Beverage
2 m DOL-1204-G02MN 6028128
5 m DOL-1204-G05MN 6028130
Plug connector, M12, 8-pin, straight
Connector type Sheath material Cable length Model name Part no.
Connector M12,Enclosure rating IP 67
PVC2 m DOL-1205-G02M 6008899
5 m DOL-1205-G05M 6009868
PUR halogenfree
2 m DOL-1205-G02MC 6025906
5 m DOL-1205-G05MC 6025907
Power supply
Description Part no.
Power supply, 100 ... 240 V AC/24 V DC, 2.1 A, IP 20 6008899
Electronic module
Design Part no.
Contactless electronic switch 20 ... 250 V AC/ V DC 6038669
Double relay (DPDT) 20 ... 72 V DC / 20 ... 250 V AC 6038671
Transistor output (NPN/PNP) 10 ... 55 V DC 6038672
Namur output 6038670
Lock nut fitting
Design Model name Part no.
-1 ... 64 bar, LFV330 with G ¾ A thread G 1 A / 316 L BEF-MU-316G10-ALFV 5322463
8 0 1 3 1 7 0 | 0 1 - 0 2 - 2 0 1 0 S I C K 1 5 Subject to change without notice.
Notes
LFV300LFV300
Plug connector, M8, 4-pin, straight
Connector type Sheath material Cable length Model name Part no.
Connector M8, Enclosure rating IP 67
PVC2 m DOL-0804-G02M 6009870
5 m DOL-0804-G05M 6009872
PUR halogenfree
2 m DOL-0804-G02MC 6025894
5 m DOL-0804-G05MC 6025895
Plug connector, M12, 4-pin, straight
Connector type Sheath material Cable length Model name Part no.
Connector M12,Enclosure rating IP 67
PVC2 m DOL-1204-G02M 6009328
5 m DOL-1204-G05M 6009866
PUR halogenfree
2 m DOL-1204-G02MC 6025900
5 m DOL-1204-G05MC 6025901
Food & Beverage
2 m DOL-1204-G02MN 6028128
5 m DOL-1204-G05MN 6028130
Plug connector, M12, 8-pin, straight
Connector type Sheath material Cable length Model name Part no.
Connector M12,Enclosure rating IP 67
PVC2 m DOL-1205-G02M 6008899
5 m DOL-1205-G05M 6009868
PUR halogenfree
2 m DOL-1205-G02MC 6025906
5 m DOL-1205-G05MC 6025907
Power supply
Description Part no.
Power supply, 100 ... 240 V AC/24 V DC, 2.1 A, IP 20 6008899
Electronic module
Design Part no.
Contactless electronic switch 20 ... 250 V AC/ V DC 6038669
Double relay (DPDT) 20 ... 72 V DC / 20 ... 250 V AC 6038671
Transistor output (NPN/PNP) 10 ... 55 V DC 6038672
Namur output 6038670
Lock nut fitting
Design Model name Part no.
-1 ... 64 bar, LFV330 with G ¾ A thread G 1 A / 316 L BEF-MU-316G10-ALFV 5322463
AustraliaPhone +61 3 9497 4100 1800 33 48 02 – tollfreeE-Mail [email protected]
Belgium/LuxembourgPhone +32 (0)2 466 55 66E-Mail [email protected]
BrasilPhone +55 11 3215-4900E-Mail [email protected]
Ceská RepublikaPhone +420 2 57 91 18 50E-Mail [email protected]
ChinaPhone +852-2763 6966E-Mail [email protected]
DanmarkPhone +45 45 82 64 00E-Mail [email protected]
DeutschlandPhone +49 211 5301-301E-Mail [email protected]
EspañaPhone +34 93 480 31 00E-Mail [email protected]
FrancePhone +33 1 64 62 35 00E-Mail [email protected]
Great BritainPhone +44 (0)1727 831121E-Mail [email protected]
IndiaPhone +91–22–4033 8333E-Mail [email protected]
IsraelPhone +972-4-999-0590E-Mail [email protected]
ItaliaPhone +39 02 27 43 41E-Mail [email protected]
JapanPhone +81 (0)3 3358 1341E-Mail [email protected]
NederlandsPhone +31 (0)30 229 25 44E-Mail [email protected]
Norge Phone +47 67 81 50 00E-Mail [email protected]
ÖsterreichPhone +43 (0)22 36 62 28 8-0E-Mail [email protected]
PolskaPhone +48 22 837 40 50E-Mail [email protected]
Republic of KoreaPhone +82-2 786 6321/4E-Mail [email protected]
Republika SlowenijaPhone +386 (0)1-47 69 990E-Mail [email protected]
RomâniaPhone +40 356 171 120 E-Mail [email protected]
RussiaPhone +7 495 775 05 34E-Mail [email protected]
SchweizPhone +41 41 619 29 39E-Mail [email protected]
SingaporePhone +65 6744 3732E-Mail [email protected]
SuomiPhone +358-9-25 15 800E-Mail [email protected]
SverigePhone +46 10 110 10 00E-Mail [email protected]
TaiwanPhone +886 2 2375-6288E-Mail [email protected]
TürkiyePhone +90 216 587 74 00E-Mail [email protected]
USA/Canada/MéxicoPhone +1(952) 941-6780 1 800-325-7425 – tollfreeE-Mail [email protected]
SICK AG | Waldkirch | Germany | www.sick.com
8013
170/
2010
-02-
01 /
FD ∙
Prin
ted
in G
erm
any
(201
0-10
) ∙ S
ubje
ct to
cha
nge
with
out n
otic
e ∙ T
he s
peci
fied
prod
uct f
eatu
res
and
tech
nica
l dat
a do
not
repr
esen
t any
gua
rant
ee ∙
01 U
S m
odifi
ed 4
c in
t32